Loading...
Staff Report PZChanges to Agenda: Item #46 & C: Summertree (RZ-13-014; PP-13-035): The applicant has requested withdrawal of this project. Item #4F & G: TM Creek (AZ-13-015; PP-13-030): The applicant has requested continuance of this project to the February 6, 2014 PIZ hearing. Item #4A: Falconers Place (PP-13.039) Application(s): Preliminary plat, development agreement modification and alternative compliance Size of property, existing zoning, and location: This site consists of 4.69 acres of land, zoned R-8, and is located at the southeast corner of E. Falcon Drive and S. Eagle Road. History: In 2005, the property received the annexation, preliminary plat and conditional use permit to construct and operate an assisted living facility comprised of 5 individual facilities on the property. The property is governed by a development agreement which restricts the use of the property to the assisted living facility. In 2008, the same development was approved however; the developer at the time failed to submit a time extension application or record the plat and establish the use on the site within the time limits of the UDC. Adjacent Land Use & Zoning: The surrounding area is primarily developed as single family residential; zoned RUT, R-4 and R-8. Comprehensive Plan FLUM Designation: LDR Summary of Request: The applicant has applied PP, MDA and ALT to develop a single family development consisting of one existing single family residence and 36 townhomes in the R-8 zoning district. The R-8 zone was established on the property to develop an assisted living facility. The previous developer requested astep-up in the density/zoning as allowed in the comprehensive plan. For purposes of this application, the comprehensive plan becomes the advisory tool for determining the future land use and the underlying zoning regulates the use and the density in which the property may be developed. The applicant is proposing to subdivide the property into 2 buildable lots that consists of 1 existing single-family detached home (Lot 1, Block 1) and thirty-six (36) proposed townhomes (Lot 2, Block 1) on 4.69 acres of land. Gross density proposed for this project is 7.87 dwelling units to the acre. Although the density is greater than the anticipated density of the comprehensive plan, the use and density proposed with the development is allowed in the R-8 zone and consistent with the step-up in density allowed in the Comprehensive Plan. All of the proposed lots comply with the dimensional standards of the UDC. Access to this development will be provided from E. Falcon Drive. The existing single family residence will continue to take access from this roadway. The townhome portion of the development will take access from the extension of S. Falconers Place through a blanket reciprocal ingress/egress easement. The applicant has requested alternative compliance to deviate from the 20' X 20' parking pad requirement in front of the townhomes. In lieu of the parking pads, the applicant is proposing three (3) overFlow parking stalls at the end of the each townhome driveway which increases the amount of useable open space within the development. To address staffs concerns with the parking ratio in the SEC, the applicant has provided a revised plan increasing parking as recommended by staff. The UDC does not require compliance with the common open space and site amenity standards. The only required landscaping is a 25-foot wide landscape buffer adjacent to S. Eagle Road. 2.74 acres of open space and 2 amenities (a sitting area with a decorative trellis and a plaza area) are being provided for the townhome portion of the development. The submitted elevations depict three color schemes and a mix of building materials (lap siding and cedar shake siding), decorative window and door trim, decorative corbels, belly bands, covered entries, and stone wainscot consistent with the surrounding developments. Through the CZC and DES process, staff will ensure the compliance with the building materials, colors and design features proposed with the submitted elevations. Written Testimony: Ronald Mowery, Brady and Teresa Turner & Rick and Michelle Stott has submitted written testimony if opposition of the proposed project. Primary concerns are density, use and incompatibility with surrounding development. Staff Recommendation: Approval w/conditions Notes: STAFF REPORT E IDIAN ^' Hearing Date: January 16, 2014 TO: Planning and Zoning Commission FROM: Bill Parsons, Associate City Planner (208) 884-5533 Bruce Freckleton, Development Services Manager (208)887-2211 SUBJECT: PP-13-039; MDA-13-024 and ALT-13-025 -Falconers Place 1. SUMMARY DESCRIPTION OF APPLICANT'S REQUEST The applicant, Falcon Drive Meridian, LLC, is requesting approval of the following applications: 1) Preliminary plat (PP) consisting of two (2) residential lots and one (1) common lot on 4.69 acres in an R-8 zoning district; 2) Development agreement modification (MDA) to change the development plan from an assisted living facility consisting of six (6) buildings to a 36-unit townhome development and; 3) Alternative compliance to deviate from the required 20' X 20' parking pads in front of the townhomes. 2. SUMMARY RECOMMENDATION Staff recommends approval of the proposed preliminary plat, development agreement modification and alternative compliance applications with the conditions listed in Exhibit B, based on the Findings of Fact and Conclusions of Law in Exhibit C. 3. PROPOSED MOTION Approval After considering all staff, applicant and public testimony, I move to recommend approval to the City Council of File Numbers PP-13-039, (MDA-13-024 and ALT-13-025 optional) as presented in staff report for the hearing date of January l 6, 2014 with the following modifications: (Add any proposed modifications.) Denial After considering all staff, applicant and public testimony, I move to recommend denial to the City Council of File Numbers PP-13-039, (MDA-13-024 and ALT-13-025 optional) as presented in staff report for the hearing date of January 16, 2014 for the following reasons: (You should state specific reasons for denial of the applications.) Continuance I move to continue File Numbers PP-13-039, (MDA-13-024 and ALT-13-025 optional) to the hearing date of (insert continued hearing date here) for the following reason(s): (You should state specific reason(s) for continuance.) 4. APPLICATION AND PROPERTY FACTS a. Site Address/Location: Falconers Place - PP-13-039, MDA-13-024 & ALT-13-025 PAGE 1 The site is located southeast corner of E. Falcon Drive and S. Eagle Road in the NW '/4 of Section 28, T3N., R.lE. (Parcel's 8319250021 and 8319250023) b. Owners: Falcon Drive Meridian, LLC 3330 E. Louise Drive, Suite #300 Meridian, ID 83642 Ronald Mowery 3295 E. Falcon Drive Meridian, ID 83642 c. Applicant: Falcon Drive Meridian, LLC 3330 E. Louise Drive, Suite #300 Meridian, ID 83642 d. Representative: Laren Bailey, LEI Engineers and Surveyors 3023 E. Copper Point Drive Meridian, Idaho 83642 e. Applicant's Request: Please see applicant's narrative for this information. 5. PROCESS FACTS a. The subject applications are for a preliminary plat, development agreement modification and alternative compliance. A public hearing is required before the Planning and Zoning Commission and City Council on this matter, consistent with Meridian City Unified Development Code Title 11, Chapter 5. b. Newspaper notifications published on: December 30, 2013 and January 13, 2014 (Commission); c. Radius notices mailed to properties within 300 feet on: December 23, 2013 (Commission); d. Applicant posted notice on site by: January 3, 2014 (Commission); 6. LAND USE a. Existing Land Use(s): A portion of the site (0.50 acres) is developed with a single family detached home and will remain on Lot 1, Block 1 of the proposed subdivision. The remaining vacant acreage (4.19 acres) is proposed to develop with the thirty-six (36) townhomes. The entire property is zoned R-8. b. Description of Character of Surrounding Area and Adjacent Land Uses and Zoning: The surrounding area is primarily developed as single family residential; zoned RUT in Ada County, R-4 and R-8. c. History of Previous Actions: • In 2005, City Council approved the annexation, preliminary plat and conditional use permit (AZ-OS-027, PP-OS-027 and CUP-OS-034) to construct and operate an assisted living facility comprised of 5 individual facilities on the property. As part of the annexation approval, the Developer and the City entered into a development agreement (DA) recorded under instrument #105152708. • In 2008, City Co~mcil approved a new preliminary plat and conditional use permit (PP-08- 004 and CUP-08-008) for the same use on the property however, the developer at the time failed to submit a time extension application or record the plat and establish the use on the site within the time limits of the UDC. Currently, the recorded DA restricts the use of the property to the assisted living facility. Falconers Place - PP-13-039, MDA-13-024 & ALT-13-025 PACE 2 d. Utilities: 1. Public Works: Location of sewer: The sanitary sewer main intended to provide service to this development is existing in S. Eagle Road. Location of water: Domestic water mains to provide service to this development are existing in S. Eagle Rd. and E. Falcon Drive. Issues or concerns: None e. Physical Features: ] . Canals/Ditches Irrigation: No major facilities transverse the subject properties. 2. Hazards: Staff is not aware of any hazards that exist on the property. 3. Flood Plain: NA 4. Topography: NA 7. COMPREHENSIVE PLAN POLICIES AND GOALS This property is designated `'Low-density Residential" (LDR) on the Comprehensive Plan Future Land Use Map. The LDR land use designation anticipates residential development at gross densities of three (3) dwelling units or less to the acre. The subject property is currently zoned R- 8which allows the property to develop with a maximum of 8 dwelling units to the acre under the Unified Development Code (UDC). As mentioned above, the R-8 zone was established on the property to develop an assisted living facility. In order to develop the property with the assisted living facility, the previous developer requested astep-up in the density/zoning (e.g. low to medium) as allowed in the comprehensive plan. For purposes of this application, the comprehensive plan becomes the advisory tool for determining the future land use and the underlying zoning regulates the use and the density in which the property may be developed. Now that an assisted living facility is no longer proposed for the property, the applicant is proposing to subdivide the property into two (2) buildable lots that consists of one (I) existing single-family detached home (Lot 1, Block 1) and thirty-six (36) proposed townhomes (Lot 2, Block l) on 4.69 acres of land. Gross density proposed for this project is 7.87 dwelling units to the acre. Although the density is greater than the anticipated density of the comprehensive plan, the use and density proposed with the development is allowed in the R-8 zone and consistent with the step-up in density allowed in the Comprehensive Plan. Staff finds the following Comprehensive Plan policies to be applicable to this property to support the proposed development (staff analysis in italics below policy): `'Support a variety of residential categories (low-, medium-, medium-high and high-density single-family, multi-family, townhouses, duplexes, apartments, condominiums, etc.) for the purpose of providing the City with a range of affordable housing opportunities." (3.07.01 E) The proposed townlzome development should provide additional housing choices which is currently lacking in the area. `Permit new development only where urban services can be reasonably provided at the time of final approval and development is contiguous to the City." (3.01.01 F) The proposed development is contiguous to the city and city services are available to be extended to the site upon development in accord with UDC 11-3A-21. The recorded DA Falconers Place-PP-13-039, MDA-13-024 & ALT-]3-025 PAGE 3 requires the existing single family home to connect to City sewer and water with the first phase of development. • "Support infill of vacant lots in substantially developed, single-family areas at densities similar to surrounding development. Increased densities on vacant lots may be considered if structures are compatible with surrounding development." (3.07.02I) The subject property is surrounded by properties developed at urban densities lower than the proposed residential development. However, the residential development on the southwest corner of Victory Road and Eagle Road is developed with a mix of single family and multi- family zrnits. The applicant has submitted building elevations for the townhomes. The proposed structures are meant to emulate the surrounding single family homes by incorporating similar bz~ilding materials and design features (e.g. horizontal and cedar shake siding, decorative corbels, stone wairzseot, decorative trim, varying roof forms and bell bands). Since the proposed use of the property is principally permitted within the R-8 gone, the proposed design of the structures emulate the surrounding residences and the proposed density is consistent with a medium density development, stafffinds the development should be compatible with the surrounding single•family developments. • ``Require street connections between subdivisions at regular intervals to enhance connectivity and better traffic flow."(3.03.03C) Because this a townhome development, local street access must be provide to serve the proposed development. With the development of the subdivision, a new local street (S. Falconers Place) will be constructed to serve the townhome portion of the development. The new roadway will tie into E. Falcon Drive which connects to Eagle Road. The existing residence will continue to take access from E. Falcon Drive, a local street. No direct lot access to Eagle Road is proposed or approved with the subject application. The public streets constructed with the Karmelle Subdivision to the east connect to E. Falcon Drive and provide a Victory Road access to the proposed development. • `'Restrict private curb cuts and access points on collectors and arterial streets." (3.06.02D) See analysis above. • "Pursue sidewalk construction for existing substandard streets." (3.03.02D) The strbject property abuts E. Falcon Drive which is currently a substandard street. With the development of the subdivision, the applicant will responsible for constructing a 5-foot wide sidewalk along the entire E. Falcon Drive frontage. The plans as submitted depict a 9 foot wide parkway and a S foot wide detached sidewalk consistent with this action item. • "Provide housing options close to employment and shopping centers." (3.07.02D) The proposed development will provide additional housing options in this area of the City within close proximity to employment centers, education facilities and shopping along the Eagle and Overland Road eorridors. • "Require appropriate landscaping and buffers along transportation corridors (setbacks, vegetation, low walls, berms, etc.)." (3.06.02F). Street buffer landscaping is required adjacent to S. Eagle Road in accord with the standards listed in UDC 11-3I3-7C. Feneing shall comply with the standards listed in UDC 11-3A-7. Falconers Place-PP-13-039, MDA-13-024 & ALT-13-025 PAGE 4 `'Require usable open space to be incorporated into new residential subdivision plats." (3.07.02A) Since the plat is under the S acre minimum, the UDC does not require compliance with the common open space and site amenity standards set forth UDC 11-3G. The only required landscaping for the development is the 25 foot wide landscape buffer adjacent to S. Eagle Road. The submitted plan depicts approximately 2.74 acres of open space and two (2) amenities. Staff is supportive of the proposed open space and amenities as a typical infill development does not provide this amount of open space for the benefit of the future residents and should complement the surrounding single family developments. After considering all of these factors staff is of the opinion that the proposed development is generally consistent with comprehensive plan. 8. UNIFIED DEVELOPMENT CODE A. Purpose Statement of the Residential Districts (R-8): The purpose of the residential districts is to provide for a range of housing opportunities consistent with the Meridian Comprehensive Plan. Residential districts are distinguished by the allowable density of dwelling units per acre and corresponding housing types that can be accommodated within the density range. B. Schedule of Use Control: Unified Development Code (UDC) 11-2A-2 lists townhomes and single family detached housing as pri-lcipally permitted uses in the R-8 zoning district. C. Dimensional Standards: Development of the site shall comply with the dimensional standards listed in UDC 1 1-2A-6 for the R-8 zoning district. D. Landscaping: A 25-foot wide buffer is required to be constructed along S. Eagle Road in accord with the street buffer landscaping standards listed in UDC 1 l -3B-7C. E. Subdivision Design and Improvement Standards: The subdivision must comply with the subdivision design standards outlined in UDC 1 ] -6C-3. F. Off-Street Parking: Off-street parking is required in accord with UDC Table 11-3C-6 for townhome dwellings. The applicant is seeking alternative compliance to deviate from the rega~ired parking pads in front of the townhome garages. 9. ANALYSIS a. Analysis of Facts Leading to Staff Recommendation: Development Agreement Modification (MDA): The subject property is governed by a development agreement (DA) recorded as instru-nent # 105152708. As mentioned earlier, the previous project was approved. for an assisted living facility. To ensure the site developed as proposed at the time, the recorded DA restricted the development of this site to no more than six (6) primary structures; five (5) retirement homes and one (1) clubhor-se. The new owner is seeking the approval to construct a 36-unit townhome development. Since the proposed project differs substantially from the previous approvals, the recorded DA must be amended to incorporate new provisions relevant to the proposed development. Staff has provided the appropriate DA sections that need to be modified: • Update the Parties: Include new developer/owners; • Section 3.2: Include new developer/owners; • Section 4.1: Falconers Place - PP-13-039. MDA-13-024 & ALT-]3-025 PAGE 5 Construction and development of a residential development consisting of one (1) existin single family residence and thirty-six (361 townhomes in an R 8 zone on 4 69 acres• . <: ~: b e e ~ > • Seet1011 6: 6.1.1 • .Development of the site shall consist of a maximum of thirty six (36) townhomes and one (1) single family residence• 6. ] .2 Remain as is; • Add the following new DA provisions: 6.1.3 The applicant shall subdivide (through a condominium plat) all townhome structures m accord with UDC 1 l -6B-5. The condominium lat shall be recorded prior to occupancy of any of the dwellings 6.1.4 Future development of the site shall substantially comply with the submitted prelunmary plat landscape plan and townhome elevations attached in Exhibit A 6.1.5 All future development of the subject property shall comply with all City of Mendian ordinances in effect at the time of develo ment 6.1.6 Prior to issuance of a building permit for any townhome structure the applicant shall obtain approval of a Certificate of Zoning Compliance and Design Review application and record a final plat 6.1.7 The townhome portion of the development shall consist of approximately 2 74 acres of common open space and two (2) amenities (sitting area with trellis and plaza area as pro osed • Section 17: -Update with new owner information. Preliminary Plat (PP): The proposed preliminary plat consists of two (2) residential lots and one (l) common lot on approximately 4.69 acres of land in the R-8 zoning district. The existing single family residence will remain on Lot 1, Block 1. The property owner has given consent to be part of the application submittal. The other residential lot (Lot 2, Block 1) is proposed to develop with thirty-six (36) townhomes. The proposed gross density of the subdivision is 7.87 dwelling units per acre which is consistent with the density requirements of the R-8 zoning district. Dimensional Standards: Staff has reviewed the proposed plat for compliance with the applicable standards listed in UDC Table 11-2A-6 for the R-8 zoning district. The existing residence on Lot 1, Block ]must comply with the dimensional standards of the R-8 district. In reviewing the submitted plat the proposed lot exceeds the minimum frontage (50 ft.) and the minimum lot size requirements (5,000 square feet) in the UDC. For the townhome portion of the development, the applicant is proposing to construct the thirty- six (36) townhomes on single parcel instead of platting each individual unit on a separate parcel. The UDC does not specify a minimum lot size for the proposed townhomes however; there is a Falconers Place-PP-13-039, MUA-13-024 & ALT-13-025 PAGE 6 minimum street frontage requirement of 40 feet. The plat as submitted complies with the dimensional standards of the R-8 district. In order to convey ownership of the townhomes as single family residences, the applicant must subdivide (through a condominium plat) the townhomes in accord with UDC 11-6B-5. Lot 2, Block 1 of this application will remain under single ownership and maintained by the future homeowners association. Access: Access to this development will be provided from E. Falcon Drive; an existing local street. The existing single family residence will continue to take access from this roadway. The townhome portion of the development will take access from the extension of S. Falconers Place. Staff is supportive of the public street access proposed for the development. Access for the townhome dwellings will be done through a blanket reciprocal ingress/egress easement With the submittal of the final plat application, the applicant should add a note on the face of the plat or record a separate document and reference the recorded document number on the face of the plat that identifies a cross access/shared parking agreement for the townhome development. Parking/Alternative Compliance (ALT): The applicant has requested alternative compliance to deviate from the 20' X 20' parking pad requirement in front of the townhomes. In lieu of the parking pads, the applicant is proposing three (3) overflow parking stalls at the end of the each townhome driveway which increases the amount of useable open space within the development. Since this is a single family townhome development, the UDC requires each townhome dwelling provide a total of 4 parking spaces (two car garage and a 20' X 20' foot parking pad). Based ou the UDC requirements the townhome portion of the development would be required to provide a total of 144 parking spaces. As submitted the applicant is only proposing 87 parking spaces which is approximately a 40% reduction in the required parking. While staff is supportive of the layout and the amount of open space provided with the reduction in the parking, staff is of the opinion the applicant should add three (3) more overflow parking stalls within the cluster of four (4) townhomes located in the southeast corner. If the applicant modifies the plan as recommended, staff is supportive of the parking plan for the proposed townhome development. Prior to the Commission hearing, the applicant must submit a revised plan to accommodate the parking changes as recommended by staff. Landscaping, Open Space and Amenities: Since the plat is under the 5 acre minimum, the UDC does not require compliance with the common open space and site amenity standards set forth UDC 1 l -3G. The only required landscaping for the development is the 25-foot wide landscape buffer adjacent to S. Eagle Road. The landscape plan as submitted provides the required 25-foot wide landscape buffer in accord with UDC 1 l -3B-7C. In addition to the required landscape buffer, the submitted plat indicates that 2.74 acres of open space is being provided for the townhome portion of the development. The main reason for the increase in open space has to do with the applicant's request to reduce the required parking for the development. Further, the applicant is proposing the following two (2) amenities: a sitting area with a decorative trellis and a plaza area. Staff is supportive of the proposed open space and amenities for the development. With the submittal of the final plat application the applicant must provide details of the proposed amenities. Existing Trees: The submitted landscape plan notes existing trees on the plan proposed for removal. The applicant is responsible to mitigate all existing healthy trees 4-inch caliper or greater that are removed from the site with equal replacement of the total calipers lost on site up to an amount of 100% replacement in accord with UDC l 1-3B-10. With the submittal of the Falconers Place - PP-13-039, MDA-13-024 & ALT-13-025 PAGE 7 final plat, the applicant must submit a revised landscape plan that details the mitigation plan outlined by the developer and the City Arborist. Fencing: The submitted landscape plan depicts vinyl fencing along the south and east boundary of the townhome development. Specific details for the height of the fence have not been provided. Any future fencing proposed for the development must comply with the fencing regulations set forth in UDC 11-3A-7.With the submittal of the final plat application, the applicant must provide a master fence plan to ensure compliance with the UDC. Pressurized Irrigation: The City of Meridian requires that pressurized irrigation (PI) systems be supplied by a year-round source of water. The applicant shall be required to ~rtilize any existing surface or well water for the primary source. If a surface or well source is not available, asingle- point connection to the culinary water system shall be required. An underground, pressurized irrigation system is required to be installed in accordance with UDC l 1-3A-I5. The owner is requesting the use of domestic water to serve as the primary water source for the proposed development. The applicant states the use of surface water from Nampa Meridian Irrigation District is not feasible. The surface delivery to this property is on a 10 day rotation and cannot provide adequate water delivery. The requirements for a pressurized irrigation system may be waived if the property does not have water rights in an existing irrigation district. The applicant must submit a letter from the Nampa Meridian Irrigation District verifying the water deficiency. The city's domestic water system is the last option for providing irrigation water to a proposed development and requires City Engineer's approval. Sidewalks: Sidewalks are required along all public streets. A 5-foot wide detached sidewalk is required adjacent to S. Eagle Road. The applicant is proposing to construct a 5-foot wide detached sidewalk and 9-foot wide parkways along the south side of E. Falcon Drive and 5-foot wide attached sidewalk along both sides of S. Falconer Place. All sidewalks and parkways constructed within the development must comply with UDC 1 I-3A-17. Waterways: As per UDC 1 l -3A-6, all irrigation ditches, laterals or canals, exclusive of natural waterways and waterways being used as amenities, which intersect, cross or lie within the area being subdivided shall be covered. Existing Structures: As mentioned above, an existing home will remain on Lot 1, Block 1. Per the recorded DA, the existing residence must connect to City services with the first phase of development. Elevations: The submitted elevations depict a mix of building materials (lap siding and cedar shake siding), decorative window and door trim, decorative corbels, belly bands, covered entries, and stone wainscot consistent with the surrounding developments. Staff is of the opinion the future townhomes will complement the existing homes in the area and demonstrate high quality materials (see Exhibit A.4). Since all of the townhomes will have a similar design and building form, staff recommends the applicant provide three different color schemes as proposed to provide variation within the development. Prior to the issuance of a building permit, the applicant is required to obtain certificate of zoning compliance (CZC) and administrative design review (DES) for each townhome structure. Through the CZC and DES process, staff will ensure the compliance with the building materials, colors and design features proposed with the submitted elevations. Falconers Place - PP-] 3-039. MDA-13-024 & ALT-13-025 PAGE 8 In summary, Staff recommends approval of the proposed preliminary plat, development agreement modification and alternative compliance with the recommended conditions listed in Exhibit B of this report in accord with the Findings contained in Exhibit C. 10. EXHIBITS A. Drawings 1. Vicinity Map 2. Proposed Preliminary Plat (dated: 12/18/13) 3. Proposed Landscape Plan (dated: 1 1/l5/13) 4. Proposed Building Elevations B. Conditions of Approval 1. Planning Division 2. Public Works Department 3. Fire Department 4. Police Department 5. Parks Department 6. Republic Services 7. Ada County Highway District C. Required Findings from Unified Development Code Falconers Place-PP-13-039. MDA-13-024 & ALT-13-025 PAGE 9 A. Drawings 1. Vicinity Map ' ]u ~ I 3259 1 .' .,' 3516 ', _.Y.,-. .. _.._._ :._ - 3792 .. _,_ ._ ..._ ~ ___:. I -, ~ ~ I. ~~' ~ I c-c ~ ~ T 1 - _:_ r_,__ ~ ~ Hero i ... ' I i Dr _° I \ ~ ,,-J ~ I ~1£Cullen St ~ RL T -- I 1 0 , ; fl 3210 i I ~ ~ ~ ~ [-. _- __ i -~ _' i ~ I . _.._.-3321 '~1 j -~ 3085 !-~ ,___., , -. ~ ~ __ ~ ~ m ~E Falcon Dr 1 ^-~~ _ j ~ m'E .~, ~,~ i k .._ ~ ti 3309 1 ... f...~ _ I a i R,B~ i I i a ~ f I ' /~~/ ~,~ Ct ~ J' ~ A ~ ~ j~ f ~ ~ ?RL'T ~ E Shaver f ~- / ~ ~{ ~ ~ ~ _ __L - ~ ~Wt J.-h/ ~~ 3475 2870 _.... __ ~ Or ^~ ___ . is ; ~ 3475 \___-_ 7467 1 3515 ~ ~ 3415 -- -i - E Rome Dr _~ _ _. i -_ / 4 i 3620 j __ ~ t ;_ __.- i _ -_- -- _ _ L E Calaay, I ) I l i ! ' ~ 3677 "fib ~ -- '~, e ~ ! ~ ~', ~ ~ I o ~ ~ ~ ~~n ~~ ~aY -1 - ~ Dart~ngtori Dr ~ ... ~ ~. - ..~ ~ '~ 1:. _ ~ ~ ~ , ~. ~ ~ ~ ~ Rl?T _ - ~ ~I ~ ~ ~ ~ I 3 .R LE~a Dr ~~' p~ , ~' ~ ~ 3300 ~ ~ ~ i_-.~ ~ I ~ ~°A ~ I ~ ~ ~ ~ ~~ ~ ~1 ~ /, ~ F Dartmoor Dr - ti ~ ~.+ ~---+ ~ -,R-d. ;- a \v/ i pp ~~ i`T M r ' ` ', Jg7g .° ~ ~' ~ ~ 6~" -~ 3853 .._ 2931 '._ - ..._ /~ 9a~ ~ ~. \ 3875 ~I _~ - - Falconers Place-PP-13-039, MDA-13-024 & ALT-13-025 PAGE 8 2. Proposed Preliminary Plat (dated: 12/18/13) i ~i<<i~uE~n~i cur-;;iui,~~ i i ~ FALCONERS PLACE F v s -, ~aY7i~°. ~ _ __ ~~,'~~ W 5~ ~ " ~; ~' T~~`; i S=ao / i pia ~ W ! Z ~ ~ ~ o ' J i LL 9 1. (-,.l ~ ~ i w _~. yt ~ ~~a~~c. wwu~~ Y I C~ »~,.. ~ , I I ` ~ J ~ ~e ~ ~ _ ~" _ i ~.,, ~ ~ 3 - -~ ~.r Falconers Place - PP-13-039, MDA-13-024 & ALT-13-025 PAGE 9 3. Proposed Landscape Plan (dated:ll/15/13) r ~-Alfot; DNR'li " _ _ >r I I ~i I $I I I I I I I I I t~//i"" I f I ~~ II I I l M ~_' ----_ _~./~ r J5~ ~° = - ~_ ~~ ~_ ---- .-_..M ~~+ISrnei~CY' •_ >~~~~ ws-~~-•-_----- ~"~rsa~si~ae ~ LT.iB~LSi'~.S ~! ~e `,^ .~ _ ~~ ~ w w 1 C~ f. p ..n =w r~~_ ` r 1 __ '~.,, ~~.. ~ ~~ -C~ ~iSl,1RTi7i50}OOif 'MY~'i Asz ~~~ ~~ ~4 i... m ~ :tr~ + y~ saf5',;?;, p ~ E _ -,~ +. r. I. i. 1-1 'gym' °~ ~_• . L1.1 Falconers Place-PP-13-039, MDA-13-024 & ALT-13-025 PAGE 10 z,4;t=ttslE4S~{ _ ~~s'a ~ ._ '~~ ~ >~t~«,i: is Q ~S if ~~ y~ i t r~ i~c . _ ~e~Ls i • ~U CCj .-+ a a~ 0 V tCS . n C =Y Falconers Place- PP-13-039, MDA-13-024 & ALT-13-025 PAGE 11 4. Building Elevations ^• [! -'. IR it f ,r .,. 'f, q-p-. '° ... ..; ~- ~~'; Falconers Place-PP-13-039, MDA-13-024 & AL1'-13-025 PAGE 12 FAI_COPJFP,S Pt_ACF TRIPLEX ELEVA?ION COL(JFt OP710N: B F:4lCC1NEP,S PLA.i;e 7P.3P1 EX EiLE?/1TIOtJ COLOR OPTiO!J: t. Falconers Place - PP-13-039, MDA-13-024 & ALT-] 3-025 PAG}; ] 3 B. Conditions of Approval 1. PLANNING DEPARTMENT I.l Development Agreement Modification 1.l .1 The DA shall be signed by the property owner and returned to the City within two years of the City Council granting the approval. The amended DA must be approved and recorded prior to submitting any final plat for review and approval. The applicant shall contact the City Attorney's office (898-5506) to initiate this process. The amended DA shall include the following modification: • Update the Parties: Include new developer/owners; • Section 3.2: Include new developer/owners; • Section 4.1: ______.._ . _ , ,,.,, u,., Construction and development of a residential development consisting of one (I) existin single family residence and th~rtv-six (36) townhomes m an R 8 zone on 4 69 acres ' ~ .,, ,,, > , • Section 6: 6.1.1 Ong Development of the site shall consist of a maximum of thirty six (36) townhomes and one (1 smile family residence• 6.1.2 Remain as is; • Add the following new DA provisions: 6.1.3 The applicant shall subdivide (through a condominium plat) all townhome structures in accord with UDC ] 1-6B-5. The condominium lat shall be recorded rior to occu anc of any of the dwelling 6.1.4 Future development of the site shall substantially comply with the submitted preliminary ]mat, landscape plan and townhome elevations attached in Exhibit A 6.1.5 All future development of the subiect property shall comply with all City of Meridian ordinances m effect at the tune of develo ment 6.1.6 Prior to issuance of a buildin ermit for an townhome structure the a licant shall obtain approval of a Certificate of Zoning Compliance and Desi n Review application and record a final plat 6.1.7 The townhome portion of the development shall consist of approximately 2 74 acres of common open space and two (2) amenities (sitting area with trellis and plaza area) as pro osed. Falconers Place-PP-13-039, MDA-13-024 & ALT-13-025 PAGI; 14 • Section 17: -Update with new owner information. 1.2 Preliminary Plat -Site Specific Conditions of Approval 1.2.1 The preliminary plat, dated 12/18/13, shall be revised as follows: a. Direct lot access to S. Eagle Road is prohibited in accord with UDC 1 1-3A-3. b. The applicant shall add a note on the face of the final plat or record a separate document and reference the recorded document number on the face of the plat that identifies the blanket cross access and shared parking agreement for the development. c. [n order to convey ownership of the townhomes, the applicant must condo the townhomes in accord with UDC 1 l -6B-5. The single parcel (Lot 2, Block 1) must remain under single ownership and maintained by the future homeowners association. 1.2.2 The landscape plan, dated 11/15/13 shall be revised as follows: a. All fencing proposed with the development shall be installed in accordance with UDC l 1-3A- 7. Submit a detailed fence plan with the final plat application. b. The applicant shall comply with the open space and site amenities represented on the submitted landscape plan attached in Exhibit A.3. With the submittal of the final plat application the applicant shall provide details of the proposed sitting area and plaza area amenities. c. Construct a 25-foot wide landscape buffer adjacent to S. Eagle Road in accord with UDC 1 1- 3B-7C. The width of the landscape buffer shall be measured from the ultimate curb location as anticipated by ACHD. The detached sidewalk shall have an average minimum separation of greater than four feet (4') to back of curb. The revised landscape plan shall depict the ultimate right-of--way (curb location) as anticipated by ACHD to ensure the required 25-foot landscape buffer is being provided in accord with UDC 1 1-3B-7C. d. Per UDC l 1-3B-] 0, the applicant shall work with the City Arborist, Elroy Huff, on designing, adopting, and implementing a protection and mitigation plan for the existing trees on site. With the submittal of the final plat the applicant shall submit a revised landscape plan that details the mitigation plan outlined by the developer and the City Arborist. e. Upon installation of the landscaping and prior to inspection by Planning Division staff, the applicant shall provide a written certificate of completion as set forth in UDC l 1-3B-14A. 1.2.3 Per UDC 1 l -SB-SB2, the Director approved the alternative compliance to deviate from constructing the 20' X 20' parking pads in front of the townhome dwellings for the western portion of the townhome development as proposed. Prior to the Commission hearing, the applicant shall submit a revised plat depicting three (3) additional overflow parking stalls within the cluster of four (4) townhomes located in the southeast corner. Parking in front of these dwellings shall be prohibited. 1.2.4 Prior to the issuance of a building permit, the applicant shall obtain certificate of zoning compliance (CZC) and administrative design review (DES) for each townhome structure home and record a final plat. 1.2.5 The existing residence on Lot l ,Block 1 must connect to City services (water and sewer) with the first phase of development. 1.2.6 Future townhomes constructed within the subdivision must comply with the submitted elevations in Exhibit A.4. At a minimum, the proposed townhome structures shall incorporate three (3) color schemes as proposed. Falconers Place - PP-li-039, MDA-13-024 & ALT-13-025 PAGE 15 1.2.7 Comply with all ACHD conditions of approval. 1.2.8 Staff's failure to cite specific ordinance provisions does not relieve the applicant of responsibility for compliance. 1.3 General Conditions of Approval 1.3.1 Comply with all bulk, use, and development standards of the R-8 zoning district listed in UDC Chapter 2 District regulations. 1.3.2 Provide a pressurised irrigation system consistent with the standards as set forth in UDC 11-3A- 15, UDC 1 1-3B-6 and MCC 9-1-28. Before city water is to be used for irrigating the proposed development, the applicant must provide documentation from the applicable irrigation district (NMID) that the property does not have water rights in an existing irrigation district. The use of domestic water is at the discretion of the City Engineer. 13.3 Comply with the sidewalk and parkway standards as set forth in UDC 11-3A-17. 1.3.4 Install all utilities consistent with the standards as set forth in UDC 11-3A-21 and ] 1-3B-SJ. l .3.5 Comply with all subdivision design and improvement standards as set forth in UDC 11-6C-3, including but not limited to driveways, easements, blocks and mailbox placement. 1.3.6 Construct storm water integration facilities that meet the standards as set forth in UDC 1 1-3B- 11C. 1.4 Process Conditions of Approval l .4.1 No signs are approved with this application. Prior to installing any signs on the property, the applicant shall submit a sign permit application consistent with the standards in UDC Chapter 3 Article D and receive approval for such signs. 1.4.2 The final plat, and any phase thereof, shall substantially comply with the approved preliminary plat as set forth in UDC l 1-6B-3C2. l .4.3 The preliminary plat approval shall be null and void if the applicant fails to either 1) obtain the City Engineer signature on a final plat within two years, or 2) gain approval of a time extension as set forth in UDC 11-6B-7. 1.4.4 The project is subject to all current City of Meridian ordinances and previous conditions of approval associated with this site (AZ-OS-027) and amended development agreement. 1.4.5 The applicant and/or assigns shall have the continuing obligation to provide irrigation that meets the standards as set forth in UDC 11-3B-6 and to install and maintain all landscaping as set forth in UDC l 1-3B-5, UDC 11-3B-13 and UDC l 1-3B-14. 1.4.6 All common open space and site amenities shall be maintained by an owner's association as set forth in UDC 11-3G-3F1. The applicant shall record legally binding documents that state the maintenance and ownership responsibilities for the management of the development, including but not limited to structures, parking, common areas, private driveways, amenities and other development features. A copy of the recorded document shall be submitted with the first Certificate of Zoning Compliance (CZC). 1.4.7 The applicant has a continuing obligation to comply with the outdoor lighting provisions as set forth in UDC 11-3A-1 1. 2. PUBLIC WORKS DEPARTMENT 2.1 General Conditions of Approval Falconers Place-PP-]3-039, MDf1-13-024 & ALT-13-025 PAGE 16 2.1.1 Applicant shall coordinate water and sewer main size and routing with the Public Works Department, and execute standard forms of easements for any mains that are required to provide service outside of a public right-of--way. Minimum cover over sewer mains is three feet, if cover from top of pipe to sub-grade is less than three feet than alternate materials shall be used in conformance of City of Meridian Public Works Departments Standard Specifications. 2.1.2 Per Meridian City Code, the applicant shall be responsible to install sewer and water mains to and through this development. 2.1.3 The applicant shall provide easement(s) for all public water/sewer mains outside of public right of way (include all water services and hydrants). The easement widths shall be 20-feet wide for a single utility, or 30-feet wide for two. The easements shall not be dedicated via the plat, but rather dedicated outside the plat process using the City of Meridian's standard forms. The easement shall be graphically depicted on the plat for reference purposes. Submit an executed easement (on the form available from Public Works), a legal description prepared by an Idaho Licensed Professional Land Surveyor, which must include the area of the easement (marked EXHIBIT A) and an 81/2" x 1 1"map with bearings and distances (marked EXHIBIT B) for review. Both exhibits must be sealed, signed and dated by a Professional Land Surveyor. DO NOT RECORD. Add a note to the plat referencing this document. 2.1.4 The City of Meridian requires that pressurized irrigation systems be supplied by a year-round source of water (MCC 12-13-83). The applicant should be required to use any existing surface or well water for the primary source. If a surface or well source is not available, asingle-point connection to the culinary water system shall be required. If a single-point connection is utilized, the developer will be responsible for the payment of assessments for the common areas prior to receiving development plan approval. 2.1.5 Atl existing structures that are required to be removed shall be prior to signature on the final plat by the City Engineer. 2.1.6 All irrigation ditches, laterals or canals, exclusive of natural waterways, intersecting, crossing or lying adjacent and contiguous to the area being subdivided shall be tiled per UDC l l -3A-6. Plans shall be approved by the appropriate irrigation/drainage district, or lateral users association (ditch owners), with written approval or non-approval submitted to the Public Works Department. If lateral users association approval can't be obtained, alternate plans shall be reviewed and approved by the Meridian City Engineer prior to final plat signature. 2.l .7 Any existing domestic well system within this project shall be removed from domestic service per City Ordinance Section 9-1-4 and 9 4 8 contact the City of Meridian Engineering Department at (208)898-5500 for inspections of disconnection of services. Wells may be used for non-domestic purposes such as landscape irrigation if approved by Idaho Department of Water Resources Contact Robert B. Whitney at (208)334-2190. 2.1.8 Any existing septic systems within this project shall be removed from service per City Ordinance Section 9-1-4 and 9 4 8. Contact Central District Health for abandonment procedures and inspections (208)375-5211. 2.1.9 Street signs are to be in place, sanitary sewer and water system shall be approved and activated, fencing installed, drainage lots constructed, road base approved by the Ada County Highway District and the Final Plat for this subdivision shall be recorded, prior to applying for building permits. 2.1.10 A letter of credit or cash surety in the amount of 110% will be required for all uncompleted fencing, landscaping, amenities, etc., prior to signature on the final plat. Falconers Place - PP-13-039, MDA-13-024 & ALT-13-025 PAGE 17 2.1.1 l All development improvements, including but not limited to sewer and water, fencing, micro- paths, pressurized irrigation and landscaping shall be installed and approved prior to obtaining certificates of occupancy. 2.1.12 Applicant shall be required to pay Public Works development plan review, and construction inspection fees, as determined during the plan review process, prior to the issuance of a plan approval letter. 2.1.13 It shall be the responsibility of the applicant to ensure that all development features comply with the Americans with Disabilities Act and the Fair Housing Act. 2.1.14 Applicant shall be responsible for application and compliance with any Section 404 Permitting that may be required by the Anny Corps of Engineers. 2.1.15 Developer shall coordinate mailbox locations with the Meridian Post Office. 2.1.16 All grading of the site shall be performed in conformance with MCC l 1-12-3H. 2.1.17 Compaction test results shall be submitted to the Meridian Building Department for all building pads receiving engineered backfill, where footing would sit atop fill material. 2.1.18 The engineer shall be required to certify that the street centerline elevations are set a minimum of 3-feet above the highest established peak groundwater elevation. This is to ensure that the bottom elevation of the crawl spaces of homes is at least 1-foot above. 2.l .l9 The applicants design engineer shall be responsible for inspection of all irrigation and/or drainage facility within this project that do not fall under the jurisdiction of an irrigation district or ACRD. The design engineer shall provide certification that the facilities have been installed in accordance with the approved design plans. This certification will be required before a certificate of occupancy is issued for any structures within the project. 2.1.20 At the completion of the project, the applicant shall be responsible to submit record drawings per the City of Meridian AutoCAD standards. These record drawings must be received and approved prior to the issuance of a certification of occupancy for any structures within the project. 2.1.21 100 Watt and 250 Watt, high-pressure sodium street lights shall be required on all public roadways per the City of Meridian Improvement Standards for Street Lighting. All street lights shall be installed at developer's expense. Final design shall be submitted as part of the development plan set for approval, which must include the location of any existing street lights. Street lighting is required at intersections, corners, cu]-de-sacs, and at a spacing that does not exceed that outlined in the Standards. The contractor's work and materials shall conform to the ISPWC and the City of Meridian Supplemental Specifications to the ISPWC. 2.1.22 The City of Meridian requires that the owner post to the City a performance surety in the amount of 125% of the total construction cost for all incomplete sewer, water and reuse infrastructure prior to final plat signature. This surety will be verified by a line item cost estimate provided by the owner to the City. The surety can be posted in the fore of an irrevocable letter of credit, cash deposit or bond. Please contact Land Development Service for more information at 887-221 1. 2.1.23 The City of Meridian requires that the owner post to the City a warranty surety in the amount of 20% of the total construction cost for all completed sewer, water and reuse infrastructure for duration of two years. This surety will be verified by a line item cost estimate provided by the owner to the City. The surety can be posted in the form of an irrevocable letter of credit, cash depositor bond. Please contact Land Development Service for more information at 887-221 1. 3. FIRE DEPARTMENT Falconers Place - PP-13-039, MDA-13-024 & ALT-13-025 PAGE 18 3.1 One and two family dwellings not exceeding 3,600 square feet require afire-flow of 1,000 gallons per minute for a duration of 2 hours to service the entire project. One and two family dwellings in excess of 3,600 square feet require a minimum fire flow as specified in Appendix B of the hiten~ational Fire Code. Fire Hydrant spacing shall be provided as required by Appendix C of the International Fire Code. 3.2 Final Approval of the fire hydrant locations shall be by the Meridian Fire Department. a. Fire Hydrants shall have the 4 %" outlet face the main street or parking lot aisle. b. The Fire hydrant shall not face a street which does not have addresses on it. c. Fire hydrant markers shall be provided per Public Works specifications. d. Fire Hydrants shall be placed on corners when spacing permits. e. Fire hydrants shall not have any vertical obstructions to outlets within 10'. f. Fire hydrants shall be place 18" above finish grade. g. Fire hydrants shall be provided to meet the requirements of the IFC Section 509.5. h. Show all proposed or existing hydrants for all new construction or additions to existing buildings within 1,000 feet of the project. 3.3 All entrances, internal roads, drive aisles and alleys shall have a turning radius of 28' inside and 48' outside radius. 3.4 Operational fire hydrants, temporary or pernanent street signs, and access roads with an all weather surface are required to be installed before combustible construction material is brought onto the site, as set forth in International Fire Code Section (IFC) 50].4 and Meridian amendment to IFC 10-4-2J. 3.5 Ensure that all yet undeveloped parcels are maintained free of combustible vegetation as set forth in International Fire Code Section 304.1.2. 3.6 All portions of the buildings located on this project must be within 150' of a paved surface as measured around the perimeter of the building as set forth in h~ternational Fire Code Section 503.1.1. 3.7 Fire lanes, streets and structures including the canopy height of mahire trees shall have a vertical clearance of 13'6" as set forth in International Fire Code Section 503.2.1. 4. POLICE DEPARTMFNT 4.1 The Police Department has no comments relates to this application. 5. PARKS DEPARTMENT 5.1 The Parks Department has no comments related to this application. 6. REPUBLIC SERVICES 6.l There is a concern that not enough waste receptacles/enclosures are provided to meet waste generation points and volumes generated by the proposed development. Please contact Bob Olson at Republic Services (345-1265) to discuss this matter prior to the public hearing. Failure to do so may necessitate continuance of the project to a subsequent meeting. 7. ADA COUNTY HIGHWAY DISTRICT (SITE SPECIFIC CONDITIONS FORTIICO~IING) 7.1 SITE SPECIFIC COMMENTS 7.2 STANDARD CONDITIONS OF APPROVAL 7.2.1 Any existing irrigation facilities shall be relocated outside of the right-of--way. 7.2.2 Private sewer or water systems are prohibited from being located within any ACHD roadway or right-of--way. Falconers Place-PP-13-039. MDA-13-024 & ALT-13-025 PAGE 19 7.2.3 All utility relocation costs associated with improving street frontages abutting the site shall be borne by the developer. 7.2.4 Replace any existing damaged curb, gutter and sidewalk and any that may be damaged during the construction of the proposed development. Contact Construction Services at 387-6280 (with file number) for details. 7.2.5 A license agreement and compliance with the District's Tree Planter policy is required for all landscaping proposed within ACHD right-of--way or easement areas. 7.2.6 Utility street cuts in pavement less than five years old are not allowed unless approved in writing by the District. Contact the District's Utility Coordinator at 387-6258 (with file numbers) for detai ]s. 7.2.7 All design and construction shall be in accordance with the Ada County Highway District Policy Manual, ISPWC Standards and approved supplements, Construction Services procedures and all applicable ACRD Ordinances unless specifically waived herein. An engineer registered in the State of Idaho shall prepare and certify all improvement plans. 7.2.8 In accordance with District policy, 7203.6, the applicant may be required to update any existing non-compliant pedestrian improvements abutting the site to meet current Americans with Disabilities Act (ADA) requirements. The applicant's engineer should provide documentation of ADA compliance to District Development Review staff for review. 7.2.9 Construction, use and property development shall be in conformance with all applicable requirements of the Ada County Highway District prior to District approval for occupancy. 7.2.10 It is the responsibility of the applicant to verify all existing utilities within the right-of--way. The applicant at no cost to ACHD shall repair existing utilities damaged by the applicant. The applicant shall be required to call DIGLINE (1-811-342-1585) at least two full business days prior to breaking ground within ACRD right-of--way. The applicant shall contact ACHD Traffic Operations 387-6190 in the event any ACHD conduits (spare or filled) are compromised during any phase of construction. 7.2.11 No change in the terms and conditions of this approval shall be valid unless they are in writing and signed by the applicant or the applicant's authorized representative and an authorized representative of the Ada County Highway District. The burden shall be upon the applicant to obtain written confirmation of any change from the Ada County Highway District. 7.2.12 If the site plan or use should change in the future, ACRD Planning Review will review the site plan and may require additional improvements to the transportation system at that time. Any change by the applicant in the planned use of the property which is the subject of this application, shall require the applicant to comply with ACHD Policy and Standard conditions of approval in place at the time unless awaiver/variance of said requirements or other legal relief is granted by the ACHD Commission. Falconers Place - PP-13-039, MDA-13-024 & ALT-13-025 PAGE 20 C. Required Findings from Unified Development Code 1. Preliminary Plat Findings: In consideration of a preliminary plat, combined preliminary and final plat, or short plat, the decision-making body shall make the following findings: A. The plat is in conformance with the Comprehensive Plan; Staff finds that the proposed plat and 36-unit townhome development are in general conformance with the comprehensive plan (please see Section 7 of the Staff Report for detailed analysis of specific comprehensive plan action items that apply to this development). B. Public services are available or can be made available and are adequate to accommodate the proposed development; Staff finds that services can be made available to accommodate the proposed development. C. The plat is in conformance with scheduled public improvements in accord with the City's capital improvement program; Because the developer is installing sewer, water, and utilities for the development at their cost, staff finds that the subdivisions will not require the expenditure of capital improvement funds. D. There is public financial capability of supporting services for the proposed development; Staff recommends the Commission and Council rely upon comments from the public service providers (i.e., police, fire, ACHD, etc.) to determine this finding. E. The development will not be detrimental to the public health, safety or general welfare; and Staff is not aware of any health, safety or environmental problems associated with the development of this subdivision that should be brought to the Council or Commission's attention. ACHD considers road safety issues in their analysis. Staff recommends that the Commission and Council reference consider the facts, analysis and any public testimony that may be presented to determine whether or not the proposed subdivision may cause health, safety or environmental problems of which staff is unaware. F. The development preserves significant natural, scenic or historic features. Staff is unaware of any nahtral, scenic or historic features on this site. Therefore, staff finds that the proposed development will not result in the destruction, loss or damage of any nahtral, scenic or historic feature(s) of major importance. The Commission and Council may consider any public testimony that may be presented to determine whether or not the proposed development may destroy or damage a natural or scenic feature(s) of major importance of which staff is Lmaware. 2. Alternative Compliance Findings: In order to grant approval for alternative compliance, the director shall determine the following findings: 1. Strict adherence or application of the requirements is not feasible; OR Falconers Place - PP-13-039, MDA-13-024 & ALT-13-025 PAGE, 21 Staff finds that strict application of the parking standards is not feasible to support the design concept and provide the amount of open space desired by the applicant. Staff supports the slight reduction in parking to provide more useable open space within the development. 2. The alternative compliance provides an equal or superior means for meeting the requirements; and Staff finds the alternative compliance provides an equal means for meeting the City's parking standards as follows: l) it allows for more flexibility in the design of the development; 2) increases the amount of useable open space and; 3) provides additional parking options for meeting the intent of the parking standards 3. The alternative means will not be materially detrimental to the public welfare or impair the intended uses and character of the surrounding properties. Staff finds that the proposed alternative will not be detrimental to the public welfare or impair the use/character of the surrounding properties if the parking pads are provided in front of the eighteen (18) townhome dwellings located on the east side of S. Falconers Place. Falconers Place-PP-13-039, MDA-13-024 & ALT-13-025 PAGE 22