Loading...
Portico at Meridian SP 08-033L !A~ ^~P j 4F y~.~ 1 ~~,.~~„ ~~. ,: i Planning Department SIGN PERMIT APPLICATION Type of Review Requested (check all that apply) ~ Sign Permit Total value of sign(s) (escludir~g value of elecdrical portion & cost of installation: $ 45,000.00 Total value of electrical portion only (niter obtain eiecrrical permit): $ 8,000.00 B Planned Sign Program ^ Temporary Sign Permit: o I S day o 30 day o 60 day o 90 day Expiration date: Applicant Information Property owner's name: GardnerAhictuist Development Phone: 246-8909 Property owner's address: ~ 390'1 W Wainwright Suite B Boise, ID Zip: 83713 Business owner's name: Gardner Ahlq"uist Development Phone: 246-8909 Business owner's address: ~ 390'1 W Wainwright Suite B Boise, ID Zjp; 837'13 Sign Contractor: Young Electric Sign Co Phone: 345-2982 "-" Sign contractor address: 416E 41 st Boise, ID -- Zip; 837 ~ 4, Primary contact is: ^ Property owner ^ Business owner ~ Sign contractor ^ Other Contact e-mail: abunneli~yesco.com Fax: 345-3064 Subject Property Information Business name: The Portico at Meridian Location/street address: NE Corner of Eagle tZd & Franklin Zoning dlStrlct: C-G Range of addresses (if PSP): Legal Description: Lot Block Subdivision Gardner Ahlquist Gateway Subdivision Is there an existing Planned Sign Program for this property? Yes No Not required COmment$• Submitting Planned Sign Program for The Portico at Meridian Subdivision Temporary Sign Permit Information (if applicable) Size of sign: Height (in feet) Width (in feet) Sign will be located: On-site Off-site Type of sign (e.g. banner, balloon, "T" frame, sandwich board, inflatable): Name of person responsible for removal of sign: Phone: Authorization Business owner/authorized agent's printed name: Angelina Bunnell Date: ~ /30/2008 Business owner/authorized agent's signatute: ,~ ~`~ Date: ~ /30/2008 STAFF USE ONLY: Date f d: File number(s)• "~ - Sign Permit Fee: ) Planning Dept. approval: Date: Z/ Building Dept. approval: Date: 660 E. Watertower Lane, Suite 202 Meridian, Idaho 83642 Phone: (208) 884-5533 Facsimile: (208) 888-6854 Website: www.meridiancity.org (Rev. 9/21/06) Memo To: The Portico at Meridian, Project File From: Jenny Veatch CC: Angelina Bunnell Date: February 20, 2008 Re: Approved Sign Program for The Portico at Meridian Angelina Bunnell of Young Electric Sign Company submitted a Planned Sign Program (PSP) application for the The Portico at Meridian (Gardner-Ahlquist Gateway Subdivision No. 1 and No. 2). This letter outlines my review and approval notes of the Planned Sign Program. The number and types of approved signage are as follows: Center Signs • One center sign, not to exceed 35 feet in height and a maximum of 200 square feet in background, shall be allowed with an approved permit. The center sign has been approved with a separate sign permit. Subdivision Identification Sign • One subdivision identification sign, not to exceed 65 feet in height and a maximum of 200 square feet in background, shall be allowed with an approved permit. The subdivision identification has been approved with a separate sign permit. • The background area of the approved subdivision identification sign shall be subtracted from the allowable background area for the center sign (UDC 11-3D- 9D.2b). Wall Signs • Future proposed wall signs must be consistent with each other in design. a b Illuminated wall signs shall be dimensional /individual letters. Sculpted and/or ~ ' bullet cabinets are allowed, but shall be secondary in nature. • No wall signs are approved with this application. • Page 1 • Future tenant signs will require separate sign permits. Freestanding Signs • Freestanding signs, not to exceed 10 feet in height and a maximum of 70 square feet in background, shall be allowed with an approved permit. Two freestanding signs have been approved with a separate sign permit. • One freestanding sign per building will be allowed. • Future tenant signs will require separate sign permits. All future and proposed signage must be in compliance with UDC 11-3D. • Page 2 The Portico at Meridian Planned Sign Program January 2008 This criterion has been established for the mutual benefit for all tenants. Conformance will be strictly enforced and any non-conforming or unapproved signs must be removed or brought into conformance at the expense of the tenant. A. GENERAL APPROVAL REQUIREMENTS 1. Before fabrication, each tenant shall be required to submit signage plans to the building's managing entity for written approval. A sign permit application including: at least two copies of detailed color drawings indicating location, layout, design and color of the proposed signs, including all lettering and or graphics with complete specifications drawn to scale accompanied by the written approval of the managing entity, shall be submitted to the City of Meridian for approval. " 2. All signs shall be in compliance with the criteria stated herein as well as Meridian City Code. In cases of any conflict between Meridian City Code and the criteria specified herein, the more restrictive requirements shall apply. 3. All permits for tenant's signs and their installation shall be obtained by tenant or tenant's representative and shall conform to all local building and electrical codes as well as the criteria set forth hereafter. 4. All tenant signs shall be designed, constructed, and installed at tenant's expense. 5. No exposed conduit, brackets, fasteners or wiring of any type will be permitted. No raceways will be allowed by landlord or permitted. 6. All signs shall meet Underwriters Laboratories and National Electrical code requirements. 7. Tenant shall be required to fulfill all the requirements of these criteria. B. NUMBER, LOCATION, DESIGN AND CONSTRUCTION OF SIGNS: 1. The development signage will consist of one subdivision identification sign (Sign A attached), one center sign (Sign C attached), and one double face tenant sign (Sign B attached). 2. Each individual building shall be permitted one freestanding monument sign per written landlord approval and design attached (Sign E) not to exceed 5' overall height and 14.04 sq. ft tenant panel. (Excluding Buildings A, B, K, & L on site plan attached.) 3. Tenants shall be permitted a maximum square footage calculated as 18% of the elevation's wall area. Wall area shall be calculated at the height time's length (H x L) of the tenant's elevation. If tenant's building has a freestanding sign, maximum allowable square footage shall be reduced by 50%. ~~ f ~a 4. Tenants in "Building D" designated on site plan attached are allowed a maximum" ~ e. ~ ~' square footage of 35% of the designated sign band area per landlord approval, and ~ ~ ~ no monument sign is allowed or permitted for this building. ~~,,~.h ~ 5. Exterior wall signs shall be individual channel letters with plex faces, internally illuminated with neon or L.E.D., and installed flush to the fascia. Sculpted and/or bullet cabinets are allowed, but shall be secondary in nature. 6. Any other signage such as temporary grand opening, etc. shall be approved by landlord prior to installation and comply with Meridian City Code. 7. Any signage on doors or windows shall be approved by landlord prior to installation and comply with Meridian City Code. C. MISCELLANEOUS REQUIREMENTS: 1. Tenant shall be responsible for the operations of tenant sign contractors. Tenant and sign contractor will be liable for any actions committed during installation or service of signage. 2. Tenant or his representative shall be responsible for cost of maintenance, service, repair or replacement of tenant's sign, time clock or electrical wiring. 3. Tenant shall be required to keep his/her sign in working order and all surfaces shall be maintained in good condition. Tenant shall also be responsible for any repair or painting for wall upon leaving of said space. 4. Upon termination of their lease, the tenant or managing entity shall neatly seal all penetrations of the building structure in a watertight condition that matches the texture, color, and material used in the construction of the building. 5. Approved sign vendor is: Young Electric Sign Company 416 East 41St Street. Boise, Idaho 83714 (208) 345-2982 Contact Leslie Brown for tenant sign criteria and design services. AHL6ZUIST DEVELOPMENT January 31, 2008 City of Meridian Sign Program Re: Portico at Meridian To Whom It May Concern: We will add the approved sign plan to our lease as an exhibit for future tenants at Portico at Meridian for retail and office users. Sincerely, Thomas Ahlquist President 12/20/2007 2:46 PM Structural Engineering Meridian Medical Plaza Eagle and Franklin Roads Meridian, ID Monument sign, 15'-0" OAH General Structural Notes: Governing Building Code: IBC 2006 Dead: Live: Snow: Wind: Seismic: Index to Calculations: Title Material Notes Column Design Footing Design Drawing 10 psf N/A psf N/A psf, flat roof Basic wind speed = 90 mph, 3 second gust Exposure = B, urban, suburban Importance Factor = 1.0 Design Category = D System =non-building structure, R = 3 Young Electric Sign Company Corporate Engineering 2401 Foothill Dr Salt Lake City, UT 84109 801-464-4600 1 2 3 4 5 .~ ~~ ~~ >~ ~. ~~. Sign Engineering 4.0 (C) 2007 Young Electric Sign Company 12/20/2007 2:46 PM MATERIALS Project: Meridian Medical Plaza Descript: Monument sign, 15'-0" OAH Structural Steel All shapes and plates: ASTM A36, except as noted otherwise Pipe: ASTM A53 GR B, Fy=35 ksi Welding Electrodes: E70XX filler steel Concrete Compressive Strength: f'c = 2500 psi at 28 days min. Cement: Type II, portand standard Soil Type: Clayey sand, type 4 Allowable Foundation Pressure: 2000 psf with increases Lateral Bearing: 150 psf /ft with increases Sign Engineering 4.0 (C) 2007 Young Electric Sign Company 12/20/2007 2:46 PM SIGN COLUMN DESIGN Project: Meridian Medical Plaza Descript: Monument sign, 15'-0" OAH Ref: Steel Construction Manual, 13th Edition, ASD Areas Subject to Wind Forces Basic: Wind S eed: 90 Ex osui-e: B Height (s) Width (B) Area Centroid Top (h) Wind 1) 2) 3) 4) 5) 6) 7) 8) 15.000 12.000 Calculation of Design Forces at Critical Heights ft M ki ft M ki in V ki @ grade 15 185 2 15.00 Column Support Design Table (Fy = 35 ksi only) 159.500 7.244 15.000 13.35 NOTE: Use actual O.D. and t only # of Column Column Length Start End Sleeve M req Mall Cols Type Size Elev Elev Depth with P~ (I'~ TS) (#) (#) (#) (in) (k~P #) (kip #) 1 P 6.63x.28 19.75 -4.75 15.00 N/A 16 19 Sign Engineering 4.0 (C) 2007 Young Electric Sign Company iz/zoi2oo7 2:46 PM LATERAL BEARING PIER AND CAISSON FOOTINGS Project: Meridian Medical P/aza Descript: Monument sign, 75' 0" OAH Ref: IBC 2006 # Footings= 1 Pass lat soil res, q= 150 psf Moment/Footing, M= 15,420 Shear/Footing, P=V= 2,129 Composite Centroid, h= 7.24 Ib-ft Ib ft Unconstrained Rectangular Pier Width, W= 3.5 Length, L= 3.5 Depth, D= (A/2)(1+ SQR(1 + (4.36h)/A))= 5.0 ft, parallel to sign face ft, perpendicular to sign face ft Actual Depth, D= 0 ft S1= (2)(q)(D/3)= 512 psf b= Sgrt(W^2 + L^2)= 4.9 ft A= (2.34)(P) / (S1)(b)= 2.0 Sign Engineering 4.0 (C) 2007 Young Electric Sign Company a ~n~ineeain~ JOB NAME MERIDIAN MEDICAL PLAZA roe Halle MERIDIAN MEDICAL • DESCRIPTION MONUMENT SIGN, 15'-0" oah oescnivnow MONUMENT SIGN JBSCO® 5'-9%s' 12'-0" . 2'-0" t. 8~-0" I 2'-011 1 1 4'-0" I I I I ~ 4'-011 1 I I I I , - r------' r-------~------ - --------I------- -------'+ O 1 I ' 1 1 I I I I ~ i i I I ~ I I I ~ i I I 1 1 1 I 1 I 1 I I I 1 1 1 1 I I I ~ i i I I I I I I I I I I 1 1 1 1 C'7 ------ ~------' 'f----- -~ -----_-_1-__-----~--'----7 1 r- r------ I i 00 1 1 I i I I ' I I 1 I I 1 I I I I I I 1 I I 1 1 I ' I 1 1 1 1 1 1 ~____--- ~------- ------ - ------- L.--_-_- ____--_J "' .:8, I I-III=1I L-I ~ 1=1 fi=ll I-~_-I ~ . I I-1 I(-1 11=1 I I-I 11=~~I I 11- ••, I a :: -. I I I~ I I=TII-III- ~ 1=11 I-11 fr I I I~I I I~I I I I~ ~ I~I ~ I~.I ~ I I ~, ~ I I_ ~. ~ . ~. ~• iTf-III-1T(=1 I I-I 1I- ' ~ I I-I ff-1 I f-1 I I-1TI= ' ~~ I IT11 IIJ I III I II I ICI a ' I .. ,111111111.11-- 3'-6" SQ. L 2 X 2 X 3/6 A36 STEEL ANGLE SIGN CABINET FRAMEWORK PIPE 6" SCH. 40 A536 STEEL CONCRETE FOOTING f'c = 2500 PSI @ 28 DAYS MIN. SOIL- CLAYEY SAND TYPE 4 ~~Sg\ONAL QQ~ ~~G1STE v F `oP~~~~ ~n l . ~,~ ~ ~o ~ \ti LOCATION MERIDIAN, ID GATE 12/20/07 BY BJ JOB NO. 301570 SHT 6 OF 6 File: W:\Boise\Meridion Medico/ Plozo.dwg Sheet: Letter Lost Modified: Dec 20, 2007 - 2:41pm 12/20/2007 3:05 PM Structural Engineering Meridian Medical Plaza Eagle and Franklin Roads Meridian, ID Monument sign, 12'-0" OAH General Structural Notes: Governing Building Code: IBC 2006 Dead: Live: Snow: Wind: Seismic: Index to Calculations: Title Material Notes Column Design Footing Design Drawing 15 psf N/A psf N/A psf, flat roof Basic wind speed = 90 mph, 3 second gust Exposure = B, urban, suburban Importance Factor = 1.0 Design Category = D System =non-building structure, R = 3 1 2 3 4 5 Young Electric Sign Company ~`ON~L Corporate Engineering Qa~C`~Q~G\STE 2401 Foothill Dr Q Salt Lake City, UT 84109 4 ~ ~ 801-464-4600 ~ ~p Uj 0 ~~~I~ ~ v Sign Engineering 4.0 (C) 2007 Young Electric Sign Company 12/20/2007 3:05 PM MATER/ALS Project: Meridian Medical Plaza Descript: Monument sign, ?2'-0" OAH Structural Steel All shapes and plates: ASTM A36, except as noted otherwise Pipe: ASTM A53 GR B, Fy=35 ksi Welding Electrodes: E70XX filler steel Concrete Compressive Strength: f'c = 2500 psi at 28 days min. Cement: Type II, portand standard Soil Type: Clayey sand, type 4 Allowable Foundation Pressure: 2000 psf with increases Lateral Bearing: 150 psf /ft with increases Sign Engineering 4.0 (C) 2007 Young Electric Sign Company r 12/20/2007 3:05 PM SIGN COLUMN DESIGN Project: Meridian Medical Plaza Descript: Monument sign, 72'-0" OAH Ref: Steel Construction Manual, 13th Edition, ASD Areas Subject to Wind Forces Basic Wind S eed` 90 - Ex osure: B Height (s) Width (8) Area Centroid Top (h) Wind 1) sign 12.000 10.250 2) 3) 4) 5) 6) 7) 8) 97.875 5.696 12.000 13.35 Calculation of Design Forces at Critical Heights y (ft) M ki ft M ki in V @ grade 7 89 12.00 Column Support Design Table (Fy = 35 ksi only) NOTE: Use actual O.D. and t only # of Column Column Length Start End Sleeve M req Mall Cols Type Size Elev Elev Depth with P Q (P, TS) (~) (~) (~) (in) (klp ~) (klp ft) 1 P 5.56x.26 16.25 -4.25 12.00 N/A 8 12 Sign Engineering 4.0 (C) 2007 Young Electric Sign Company 12/20/2007 3:05 PM LATERAL BEARING PIER AND CAISSON FOOTINGS Project: Meridian Medical Plaza Descript: Monument sign, 12'-0" OAH Ref: IBC 2006 # Footings= 1 Pass lat soil res, q= 150 psf Moment/Footing, M= 7,440 Ib-ft Shear/Footing, P=V= 1,306 Ib Composite Centroid, h= 5.70 ft Unconstrained Rectangular Pier Width, W= 3.0 Length, L= 3.0 Depth, D= (A/2)(1+ SQR(1 + (4.36h)/A))= 4.2 ft, parallel to sign face ft, perpendicular to sign face ft Actual Depth, D= 4.5 ft S1= (2)(q)(D/3)= 426 psf b= Sgrt(W"2 + L^2)= 4.2 ft Sign Engineering 4.0 (C) 2007 Young Electric Sign Company en~~neeRin~ 'JOB NAME MERIDIAN MEDICAL PLAZA LOCATION MERIDIAN, ID DESCRIPTION MONUMENT SIGN, 12'-0" OAH 'J- ®SCO. ~~~o~A~ Q~Q@`~ ~~,i~TE 2 X 2 X is A36 STEEL ANGLE GN CABINET FRAMES PE 5" SCH. 40 536 STEEL JNCRETE FOOTING = 2500 PSI AT 28 DAYS MIN. AIL- CLAYEY SAND TYPE 4 3'-0" SQ. DATE 1220107 BY B~ JOB NO. 301570 SHT 6 OF 6 ~ ~~9 E `OP~~~~ J~~i ~° "~ \~' File: W:\Boise\Meridian Medical Plaza 12'.dwg Sheet: Letter Lost Modified: Dec 20, 2007 - 3:13pm