Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Lochsa Falls Building No. 2 CZC 06-068
ciTv of ' - El RX() IDAHO MAY 15 2006 F �-e CITY OF MERIDIAN CITY C CLERK OFFIC;F � TY CERTIFICATE OF ZONING COMPLIANCE* Date: Mav 12.2006 Project Name/Number: Lochsa Falls Building No. 2 — CZC-06-068 Owner: Monterey, LLC Site Address: 2240 W. Everest Lane Proposed Use: 3,120 s.f Professional Office Comments: Conditions of Approval: Project is subject to all current City of Meridian ordinances and the Short Plat (SHP- 06-001) for Hastings Subdivision, the Conditional Use Permit (CUP -06-008) for Lochsa Falls Office Park, and the Development Agreement for Lochsa Falls Subdivision. The issuance of this permit does not release the applicant from any previous requirements of the other permits issued for this site. Landscape Plan: The Landscape Plan prepared by Habitec, on March 10, 2006, labeled Sheet L1.0, is approved (stamped "Approved" on May 12, 2006, by the Meridian Planning Department) with no changes by the Planning Department. However, please see notes for the planting schedule. The approved landscape plan is not to be altered without prior written approval of the Planning Department. No field changes to landscape plan permitted; prior written approval of all material changes is required. Site Plan: The Site Plan prepared by Habitec on March 10, 2006, labeled Sheet ALL, is approved (stamped "Approved" on May 12, 2006 by the Meridian Planning Department) with no changes from the Planning Department. The approved site plan is not to be altered without prior written approval of the Planning Department. Elevations: The Elevations prepared by,Habitec on March 10, 2006, labeled A5.1 and A5.2 is approved with no changes from the Planning. Department. Irrigation: An underground, pressurized irrigation system must be installed to all landscape areas per the approved specifications and in accordance with UDC 11-3A-15. Protection of Existing Trees: Any existing trees on site must be protected or mitigated for in accordance with the Tree Preservation section of the City's Landscape Ordinance. Per UDC 11-3B-10, coordinate with the Parks Department Arborist (Elroy Huff, 888-3579) for approval of protection/relocation measures for the existing trees prior to construction. Any severely damaged tree must be replaced in compliance with UDC 11- 3B -10-C.5. Parking: The proposed parking areas shall be paved and striped in accordance with UDC 11-313. Project engineer/architect shall certify that the number and size of handicap -accessible spaces conforms to the Americans with Disabilities Act (ADA). Handicap accessible stalls must have signage in accordance per ADA and signed appropriately. Curbing: Per UDC 11 -3B -5I, all landscape areas adjacent to driveways, parking lots, or other vehicle use areas, must be protected by curbing, wheel stops, or other approve_ d protective devices. Curbing may be cut to allow for storm water runoff. Sidewalks: All sidewalks shall be constructed in accordance with 11-3A-17. Sidewalks shall be constructed prior to occupancy. Drainage: Storm water drainage swales shall not have a slope steeper than 3:1, shall be fully vegetated, and shall be designed in compliance with UDC 11-3B-11 and UDC 11-3A-18. Fencing: Any required or proposed fencing shall be installed with current fencing standards as defined in UDC 11-3A-7. Li tin : Lighting shall not cause glare or impact the traveling public or neighboring development and comply with lighting standards as defined in UDC 11-3A-11. Signage: No signs are approved with this CZC. All business signs will require a separate sign permit in compliance with UDC 11-3D. Trash Enclosure: All dumpster(s) must be screened in accordance with UDC -11-3A-12. Trash enclosures must be built in the location and to the size approved by SSC. Handicap -Accessibility: The structure, site improvements and parking areas must be in compliance with all federal handicap -accessibility requirements. ACRD Acceptance: All impact fees, if any, shall be paid prior to the issuance of a building permit. If any changes must be made to the site plan to accommodate the ACHD requirements, a new site plan shall be submitted to the City of Meridian Planning staff for approval prior to the issuance of a building permit. Certificate of Occupancy: All required improvements must be complete prior to obtaining a Certificate of Occupancy. A written certificate of completion shall be prepared by the landscape architect, landscape designer or qualified nurseryman responsible for the landscape plan upon completion of the landscape installation. The Certificate of Completion shall verify that all landscape improvements, including plant materials and sprinkler installation, are in substantial compliance with the approved landscape plan. A Temporary Certificate of Occupancy may be obtained by providing surety to the City in the form of a Letter of Credit or cash in the amount of 110% of the cost of the remaining improvements. A bid must accompany any request for Temporary Occupancy. Plan Modifications: Except for the changes mentioned above, the approved Site Plan, Landscape Plan stamped "Approved" on May 12, 2006, and Elevations, and are not to be altered without prior written approval of the Planning Department. No significant field changes to the site or landscape plans are permitted; prior written approval of all changes is required. r Kr' ty Vigil Assistant City Planner *This letter does not indicate compliance with requirements of other departments/agencies, including, but not limited to, Ada County Highway. District, Central District Health Department, affected irrigation district(s), Meridian Sewer, Water, Building or Fire Departments, Sanitary Services Co., etc. This letter shall expire one (1) year from the date of issuance if work has not begun. 2- erid4n Type of Review Requested (check all that apply) ❑ Accessory Use ❑ Alternative Compliance Certificate of Zoning Compliance ❑ Conditional Use Permit Minor Modification ❑ Design Review ❑ Property Boundary Adjustment ❑ Short Plat ❑ Temporary Use Certificate of Zoning Compliance ❑ Time Extension (Director) ❑ Vacation ❑ Other Information Planning Department ADMINISTRATIVE REVIEW APPLICATION File number(s): C2 C— O"065 Applicant name: V Applicant address: Applicant's interest in property: _JR:Own ❑ Rent ❑ Optioned ❑ Other Owner name: Owner addres Agent name (e.., architect, engineer, dcvelo�er, representative): Firm name:. Address: jyrG� : i'i , 4� C—�-� •�i 1J Primary contact is: XApplicant ❑ Owner gent ❑ Other Contact name: E-mail: Phone: 5_ 10 Zip: 971) CY4 Phone: Zip: Phone: q_: Z S � Zip: S a 6165 Phone _6 Fax: a _JSP —��P Subject Property Information n , , I Location/street address: �� 0 q� L� + A �``�' �v 1 Assessor's parcel number(s): Township, range, section:" 1 Total acreage: Y 6i_�_ Current land use: ��i Current zoning district: 660 E. Watertower Lane, Suite 202 • Meridian, Idaho 83642 Phone: (208) 884-5533 • Facsimile: (208)88&-6854 • Website: www.meridiancitv.ore 1 Project/subdivision name: N General description of proposed project/request: U N UJ-7bo Proposed zoning district(s): r Acres of each zone proposed: l &62 Type of use proposed (check all that apply): ❑ Residential ❑ Commercial Woffice ❑ Industrial ❑ Other Amenities provided with this development (if applicable):_ 6LOSC, //J e�1 Who will own & maintain the pressurized irrigation system in this development? Which irrigation district does this property lie within? Primary Primary irrigation source: �e�©�V Ick s 1 �G�Secondary: Square footage of landscaped areas to be irrigated (if primary or secondary point of connection is City water): Residential Project Summ; Num r_of residential units: Number of co -IM Proposed number I Bedroom: and/or other lots: Number of building lots: units (for multi -family developments only): Minimum square footage of str Minimum property size (s.f): _ Gross density (D'U/acr -total land): Percentage of open space provided: Percentage of useable open space: _ excl. garage): 2 or more Bedrooms: Proposed building height: Average property size (s.f.): Net density (Macre-excluding roads & alleys): of open space: (See C er 3, Article G, for qualified open space) Type of open space provided in acres (i.e., landscaping, public, common, etc)'. Type of dwelling(s) proposed: ❑ Single-family ❑ Townhomes ❑ Duplexes Non-residential Project Summary (if applicable) Number of building lots: Other lots: Gross floor area proposed: Existing (if applicable): ! r� �5 Building height Hours of operation (days and hours): 75 _ g g Percentage of sitelproject devoted to the following:-rO7AJinn,�+^PC '�/ Landscaping: �� `� Building: vLV L Paving: 610 Total number of employees: 15 Maximum number of employees at any one time: l 0 Number and ages of students/children (if applicable : Seating capacity: Total number of parking spaces provided: — Number of compact spaces provided: 1OTAd. R20JV-� Authorization Print applicant name: Applicant signature: _ Phone: (208) 8845533 • Date: `'r= Suite 202 • Meridian, Idaho 83642 (208) 888-6854 • Website: wyviv.meridiancitv.ore 2 0 April 19, 2006 City of Meridian Planning & Development Services 660 E. Watertower Lane Ste. 202 Meridian, Idaho 83642 RE: Certificate of Zoning Compliance Lochsa Falls Office Park Building #2 To whom it may concern, Please find following our application for Certificate of Zoning Compliance for one wood frame professional office shell building to be constructed on the corner of. Chinden Blvd. and N. Long Lake Way. Building footprint is 3,120 sq. ft. and is one of eight buildings to be constructed in this office park. The site will be fully landscaped and the required parking provided for each building per the City Ordinance. Conditional use number for this project is CUP -06-008. If you have any questions regarding this application, please do not hesitate to contact me. Respectfully submitted, Bob Camp 1250 E. IRON EAGLE DR. #200 EAGLE, ID 83616 FAX (208) 438-4700 PHONE (208) 939--'%t3UU a �� y � � S NEW BUILDING SMELL WIL' LOCHSA FALLS OFFICE PARK BUILDING #2 L �Qk LOCNSA FALLS SUB. BLOCK #49, LOTS 446 PLANTIN(S SCHEDULE DAIIa oDticwrnDnl ra IF. TmK MT�OI. A RANI ryA COIpITICN EO'Il11D ]4M6 A fatliCNDMlltl%t163A DGIro' DAMT PM GCMt DIOIIT Tt1A IlmOE 0 D OMDX bIMNMLvtt' Onkelmm L10. w M1tM 0711 PAW �IOLAW OO MRNAX 6'QADILA!' A0.D RML 41lA WMA! mM TOlAlC1WK MLU[ ® D LZ U.— COM IlAII(9YOL ' lL%OLAD%A YM.IGTA' ¢MKT NmOwf 1gLT lP lrt? goll XY ODIS 11LLrodIOfO ® 1 - VwRAAA %Tiol'[AT - m -W p,��' nfy� �°'O°oY" °k,.- X001 a�R YOLDIOIII'NOIOE ° \''•r;r''•r, - /ilrl--�vYO r0 .� 100 O.i00O 'A�0010°e wit ppllt %ILrominw .,...•.••.,.'.,.,�.,. N DIf.MAD tCa1LTAtA AIA.[ ItlllllCl@el 1•fTAT 1•m MT 11tlAAt1LM O•AOIKYOL WDiD COG°TR1tlA 1EKf OLAIC VLLVCt CIOM. D•gRIXS AY Nt COVt DDIIE TILL roellOw " 1 n41D %tAeU D1LY T -Y DID Y/IC IAdb %ADR aANI A II•N1i D10Y OYDAI'M1t /'�, L/1 % (VI's/ ■DIIIOWIDRAu blIM10ID1' OIANrpJ>7aTM f ID' UL DID NAL#L9 fAIL ". O -w I L ICOI MTAICIDI Dla011A1I oil P DID I®NILVX. OJ16% VE.M—NOAIYTIYAII • •J n t%DOIII�II[w./IIEYOY• I IO• G DID 60.0DI TII1W I.t1 LFM. QN61 O.LDM DICOD AIN �' N --. Ile'fJL e•D Yelat tALlEAR 01Mtl `��{ w 1 ►� Tom. T� �'�� - _ .i �` V/� �;1�� � � oil • PLANTIN(S SCHEDULE PLAN GENERAL NOTES A. ALL RAR MEAD OIOLO W MAIWA W 1®116 Ab CLEM o a T%tLsAualees Alm lwwroao•.nm °I•at.o ar ImaA®Y neT OE oR OtCCI'E IfalAL111T. GALL RJNTgSD OIOLD K AD[NJ� AND DItDAT(9 AT GIPI M AS A R NO:LIDART TO AIE+IOID ORI'11'1 OIWIIDL 0.m PAR Q M 1181IQA6NO1bN R3Mtf, fl�D TFYT AQ TO D! OAVID MIDI DE AIOICGIlD d TK P917=AT 1NE Ola LIE YM A 19TG1lMT 16iCE 1411011fI10Uf TIE COItlDTAICtId IDTOW ASKL Ola IOD6ATld 6TD1S1D OR �mD+dL1L N•Y!, OIgID LOVflN NAV! A Ola 6R1B1 OR R•IPdI• pA1AT e1X•o1 TTlIW fA1tFOLL1]N 1RE TO DE ,i— „u , asE GEDIeIm Ao -TA NTDRD-SLIEi LANDSCAPE DATA DAIIa oDticwrnDnl ra IF. TmK MT�OI. A RANI ryA COIpITICN EO'Il11D ]4M6 A fatliCNDMlltl%t163A DGIro' DAMT PM GCMt DIOIIT Tt1A IlmOE 0 D OMDX bIMNMLvtt' Onkelmm L10. w M1tM 0711 PAW �IOLAW OO MRNAX 6'QADILA!' A0.D RML 41lA WMA! mM TOlAlC1WK MLU[ ® D OBIEXK 0.RN U.— COM IlAII(9YOL W lL%OLAD%A YM.IGTA' ¢MKT NmOwf 1gLT lP lrt? CL711 ODIS 11LLrodIOfO ® 1 - VwRAAA %Tiol'[AT - m -W cm YOLDIOIII'NOIOE ° HA�Mm/YI� YN wit ppllt %ILrominw .,...•.••.,.'.,.,�.,. N DIf.MAD tCa1LTAtA AIA.[ ItlllllCl@el 1•fTAT 1•m MT 11tlAAt1LM O•AOIKYOL WDiD COG°TR1tlA 1EKf OLAIC VLLVCt CIOM. D•gRIXS AY Nt COVt DDIIE TILL roellOw n41D %tAeU D1LY T -Y DID Y/IC IAdb %ADR aANI A II•N1i D10Y OYDAI'M1t /'�, L/1 % (VI's/ ■DIIIOWIDRAu blIM10ID1' OIANrpJ>7aTM f ID' UL DID NAL#L9 fAIL ". O -w I L ICOI MTAICIDI Dla011A1I IIO — DID I®NILVX. OJ16% VE.M—NOAIYTIYAII • •J n t%DOIII�II[w./IIEYOY• I IO• G DID 60.0DI TII1W I.t1 LFM. QN61 O.LDM DICOD AIN �' N n�n�NN- Ile'fJL e•D Yelat tALlEAR 01Mtl PLAN GENERAL NOTES A. ALL RAR MEAD OIOLO W MAIWA W 1®116 Ab CLEM o a T%tLsAualees Alm lwwroao•.nm °I•at.o ar ImaA®Y neT OE oR OtCCI'E IfalAL111T. GALL RJNTgSD OIOLD K AD[NJ� AND DItDAT(9 AT GIPI M AS A R NO:LIDART TO AIE+IOID ORI'11'1 OIWIIDL 0.m PAR Q M 1181IQA6NO1bN R3Mtf, fl�D TFYT AQ TO D! OAVID MIDI DE AIOICGIlD d TK P917=AT 1NE Ola LIE YM A 19TG1lMT 16iCE 1411011fI10Uf TIE COItlDTAICtId IDTOW ASKL Ola IOD6ATld 6TD1S1D OR �mD+dL1L N•Y!, OIgID LOVflN NAV! A Ola 6R1B1 OR R•IPdI• pA1AT e1X•o1 TTlIW fA1tFOLL1]N 1RE TO DE ,i— „u , asE GEDIeIm Ao -TA NTDRD-SLIEi LANDSCAPE DATA Tm IF. TmK I>!w Q ®A CON91AOE1 1mAL THEA ° ONDi M6RCR PAeCN6101 L.NarJI•! AIEI ]4M6 TmN.•Ci ilk/tot(A40!U Ji/(N rorAL L.uoetxl AEA tl•uAE eAa a ARCWI[CIME•0.N+NHG At&R)R L1Hf%• 1 MM•[w".a•.m m 1•P•a•n•aV 10 MAR 06 l7C waew ADA ;ODAH010 RECORDER 11J. :54 AVID NAVARRO AMOUNT 6.00BOSE 2 DEPUTY NeMftc'III II�NIIIIIIIIIINIIuiIIiN�I�I RECORDED -REQUEST OF 105156134 Title One Order No.: A0545011 S'k(:! WARRANTY DEED FOR VALUE RECEIVED, LOCHSA FAILS, LLC' an Idaho limited liability company, does hereby grant, bargain sell and convey unto MONTEREY, ITC' an the Grantor, Idaho limited liability company whose current address is 10221 Emerald, Suite 100, Boise, ID 83704, the Grantee, the following described premises, in Ada County, Idaho, TO WIT: Lots 46 and 47 in Block 49 d inOCHSA FALLS SUBDINISION NO- 12, according to the official plat thereof y filed Book 92 of Plats at Pages 10958 dough 10960, official records of Ada County, Idaho. TO HAVE AND TO HOLD the said premises, with their appurtenances unto the said Grantee, its successors assigns forever. And the said Grantor does hereby covenant to and with the said orantee, that it is the owner in fee simple of said p mruses, that dwy are frce from all encumbrances EXCEPT those to which this conveyance is expressly made subject and those made, suffered or done by the Grantee; and to all existing patent reservations, easements, ties) of way, protective covenants, zoning Viectces, and applicable building codes, laws and regulations, general taxes and � i and ch irrigation and utility assessme�s Cif any) for the current year, which are not due and pay Grantor will warrant and defend the same from all lawful claims whatsoever. Dated October .ice., 2005 LOCHSA FALLS, LLC By: Many 1 tnith, Member State of Idaho ) ) ss. County of Ada ) On this 1'7 ''day of October 2003, before me, the undersigned, a Notary Public in and for said State, personalty appeared Marty Goldsmidt known or identified to me to be a Member of the limited liability company that exec the within instrumeat and acknowledged to me that he executed the same for and on behalf of said limited liability company and that such limited liability company executed it IN WITNESS WHEREOF, I have bercunto set my hand and mixed my official seal dw in this certificate fust above written. Gt � }OZ Ait Y Notary Public for Idaho * PUB�'1G O My Commission Expires: -.qI 121 d b IDSOS Document ARTICLES OF ORGANIZATION LIMITED LIABILITY COMPANY (Instructi,ons onback of application) 1. The name dftheiimited liability company is., Monterey, LLC 2. The street address 16fihe initial registered office is: I0221 Emerald, Suite 1.00, Boise; Idaho 53704 and the name of the initial registered agent at the abov&address is: Bill Carter 3. The mailing addre.ss*f.orfuturecorreoPOndenmis' 10221 Emerald, Suite` 904?, . I Idabot3704 4, Managemeni>ofthe'liffiited:ljabillWcompany-will be�vested'in: Manager(s) [] orMernber(6) F7l iptem chea ftappraOrlata box) 5. If management is to be vested in Ofie or more manager(s), list the: narne(s) and address(ps) of at1east one initial manager. If managemerifit to be vested in the rn6rnber(t), list1he names) and addrest(es) of at least one initial member. Mime Address Bill Garter 1331 East Monterey Dr,., Boise; Idaho Robert Hosac 5.6.8 Westtwo:.Rivers Or, Eagle, Idaho 83646 Nafan .Ho6ad 114361/Vest Knsington.,Ct..,Boiisd.,.<tdahb8,37*M 6. SignaturebAktleasi.—edi Signature, Typed Name: BArtarte Capacity: Member Signature Typed Name: Capacity: Page I of I Apoisib-'% for forming1he limited liability company: Sectetwy 61 State use only ti IDAHO :xWWy:W STME CK: 25il .CI:'ii49i3 CT:'IIW IM' 1996' IDLN ON LU 12 http://,"�,"?.accessidaho-org,/public/sos/corp/search.html?ScriptForrn.startster)=doci-lew&Seri 4/17/2006 AFFIDAVIT OF LEGAL INTEREST STATE OF IDAHO ) COUNTY OF ADA ) a5 mems Xe an 1, ir&r4er 6eh,--JC AF mteen,GLC, 162,21 H/. 01r%"A �d Sure l (name) (address) (city) (state) being first duly sworn upon, oath, depose and say: That I am the record owner of the property described on the attached, and I grant my permission to: Wts , lZ s-; Iron, (e fir. L'G��e. 1D �3d lG (name) (ddress) to submit the accompanying application(s) pertaining to that property. 2. I agree to indemnify, defend and hold the City of Meridian and its employees harmless from any claim or liability resulting from any dispute as to the statements contained herein or as to the ownership of the property which is the subject of the application. 3. I hereby grant permission to City of Meridian staff to enter the subject property for the purpose of site inspections related to processing said application(s). Dated this day SUBSCRIBED AND SWORN to before me the day and year first above written. A ,(Notary Public for I 1 o f Residing at: ► — f eil C1cun , TT') My Commission Expires: /t _ %— ZD (( 04-20-'06 15:20 FROM -SSC V711JJ&UUU il.`1.J LUUJJUJrVU Da cet 4 0 co(r.pan)r Fax Number: 2088885052 T-921 P001J003 F-994 I IFWl I LV r "%IV, MAI wo �'IN1FfOA CEOtG�1 ,290 E km EWe Or, Str_ 2= Eat Q783616 2OW39-58W FAX 2M38 -97M Fax Number. 2081938,9700 Voice_ 20EV939-5800 ApPpaw .4tU SANITARY SERVICE COMPANY Ap1ved B COMMENTS; 04-20-'06 15:20 FROM -SSC 2088885052 T-921 P002/003 F-994 LOCIISA FALLS O"ICE PARK0011PING #1 - � � .. -- — . est{� � { ,����.,.�..,,,�,�.�► s � �s: 04-20-'06 15:20 FROM -SSC 2088885052 T-921 P003/003 F-994 E0/E® 39Vd 031I9dH 0046SE68OZ 9ti=TZ 960Z/61/ti9 April 19, 2006 City of Meridian Planning & Development Services 660 E. Watertower Lane Ste 202 Meridian, Idaho 83642 RE: Photometric test report for: Certificate of Zoning Compliance Lochsa Falls Office Park Buildings #1 & #2 To whom it may concern, For the certificate of zoning compliance on the above project no photometric test report is being provided at this time as per my phone conversation with Joe Guenther on past czc applications. The site and building lighting will not extend over any of the property lines and will be designed and built that way. The site and building light fixtures will not exceed 1,800 lumens each. A photometric site layout will be done and report submitted at the time of electrical plan submittal. Lighting design and construction on this project will follow the guidelines of UDC 11-3A-11. If you have any questions regarding this application, please do not hesitate to contact me. Respec fully submitted, Bob Camp 1250 E. IRON EAGLE DR. #200 EAGLE, ID 83616 FAX (208) 938-9700 PHONE (208) 939-5800 CITY OF C�Verldlan 33 E. Idaho Ave. Meridian, ID 83642 i Date q-;-'-'-1 G Applicant Address Phone �� v CASH CHECK # NAME ON CHECK IF DIFFERENT THAN APPLICANT QUAN. DESCRIPTION • i i i C�2k— o 0 zZrAA-s 946rnh PAYMENT DOES NOT INDICATE ACCEPTANCE OF APP ON TAX Received 7247 Y %/l TOTAL 55748 •�— e57,&- Ilii woe; r, Ada ountyighway istrict Right -of -Way & Development Department Planning Review Division This application requires Commission action due to the fact that the development is 862 single- -family dwellings, 171 multi -family dwellings, 11 office buildings, 1 commercial building, 1 fire station, 1 city park and 1 private park. Lochsa Falls Subdivision is scheduled to be on the consent agenda on May 22, 2002 at 6:30 pm. Tech Review for this item was held with the applicant on Friday, May 3, 2002. Please refer to attachment for Request for Reconsideration guidelines. Andrea N. T Principal Development Analyst, 208 uning, -387-6177 phone, 208-387-6393 fax. File Number(s): Lochsa Falls Subdivision / MAZ-02-010 / MPP -02-009 / MCUP-02-012 Site address: Between Linder Road and Ten Mile Road and McMillan Road and Chinden Boulevard Owner/Applicant: Farwest LLC Daniel Gibson 4487 North Dresden Place, Suite 102 Garden City, Idaho 83714 Representative: Becky Bowcutt 1405 West Chance Court Eagle, Idaho 83616 Application information The applicant is proposing to construct an 876 -lot mixed-use subdivision on 354.38. The subdivision consists of 862 single-family residential lots, 11 office lots, 1 commercial lot, 1 fire station, 1 private park, 1 City park and 59 -common lots. Acreage: 354.38 Current Zoning: RUT Proposed Zoning: R-4 Proposed buildable lots: 876 Proposed common lots: 59 Vicinity Map A. Findings of Fact 1. Commission Action on May 22, 2002: This item was originally scheduled for the May 22, 2002 consent agenda. At the request of Greg Johnson, the item was moved to the regular agenda for discussion regarding the location of Cayuse Creek Drive as it intersects Linder Road. Mr. Johnson was requesting that the Commission require the applicant to relocate Cayuse Creek Drive to the south to align with a possible driveway/street for a future high school site on the east side of Linder Road. Mr. Johnson does not own the parcel that he was requesting the street align with. The Commission approved the location of Cayuse Creek Drive as proposed, and indicated that should the developer of Lochsa Falls choose to move the location of the street, then staff had the authority to approve a relocation of the street, in accordance with District policy. The applicant requested that the Commission approve a pathway on Cayuse Creek Drive from Linder Road to the traffic circle, in lieu of sidewalk on both sides of the roadway. The Commission directed staff to work with the applicant on a possible alternative street section for that segment of roadway. The Commission noted that such an alternative would require a waiver of policy, and granted staff the authority to make such a waiver with this development. If staff and the developer cannot come to an agreement on an alternative section, then the standard requirement, as noted in this staff report, will not be changed. The applicant and District staff have come to an agreement regarding an approved pathway on Cayuse Creek Drive. The applicant has proposed to construct a 10 -foot wide asphalt pathway on the south side of Cayuse Creek Drive extending from Linder Road to the roundabout in lieu of 5 -foot concrete sidewalk on both sides of the roadway. The applicant has proposed to construct pedestrian crossings (constructed out of brick pavers) to provide pedestrians the opportunity to move from the north side of the development to the asphalt pathway on Cayuse Creek Drive. The proposed pedestrian crossings are proposed to be located at the Moose Creek Street and Cayuse Creek Drive intersection, Dry Bar Way and Cayuse Creek Drive intersection and Fish Creek Court and Cayuse Creek Drive intersection. This design is consistent with past Commission action and is approved with this application. The applicant must provide an easement for the pathway and the pathway must be owned and maintained by the Homeowners Association. 2. Trip Generation: This development is estimated to generate 12,480 additional vehicle trips per day (20 existing) based on the submitted traffic study. 3. Traffic Impact Study: A traffic impact study was required with this application. The following is a summary of the findings: This Development is projected to be built -out by the year 2010. The following are the principal findings and recommendations of the study as provided by the Traffic Engineer, and reviewed by the ACHD Transportation Engineer: • As a result of the build -out, traffic on the vicinity roadways is expected to increase as follows: traffic on Ten Mile Road and Linder Road may increase each by 1,248 vpd; traffic on Chinden Boulevard may increase by 3,495 vpd; traffic on McMillan Road may increase by 2,746 vpd. The North Meridian Study expects a trip capture up to 10% within each 1 square mile section. As more non-residential uses are developed within T4N R1 W Section 26, 10% of the site -generated trips will be retained within the section. For the purposes of this report, 90% of the project trip generation is used for assignment on the arterial roads and 10% is retained within the section. Background traffic for the year 2010 was obtained by factoring the existing traffic and adding the traffic from Bridgetower and the Keltic Heights developments. The existing traffic was projected at an annual growth factor of 2% on Ten Mile Road and.Linder Road, and 1 % on Chinden Boulevard. This was obtained from the North Meridian Area Study. • Existing Traffic Volumes on site vicinity were obtained from the North Area Meridian Traffic Study published by WIS. • The Chinden Boulevard Corridor Study completed on June 21, 1999 shows Chinden Blvd. between Ten Mile Road and Linder Road with three access points per side per mile. The intersection at Linder Road is signalized. The intersection at Ten Mile Road is controlled by a 2 -way stop sign. • The overall intersection of Linder Road and Chinden Boulevard (signal controlled) is currently operating at a LOS F with a delay of 100 seconds. At build -out of the Lochsa site, the intersection will continue to operate at LOS F with a delay of 220 seconds. • The overall intersection of Linder Road and McMillan Road (4 -way stop controlled) is currently operating at a LOS B with a delay of 11 seconds. At build -out of the Lochsa site, the intersection is projected to operate at a LOS F with a delay of 153 seconds. • At the Ten Mile Road/McMillan Road intersection (2 -way stop controlled), under current conditions, McMillan is projected to operate a LOS B or better with a delay of 11 seconds or better. At build -out of the Lochsa site, Ten Mile is projected to operate a LOS F with a delay of 83 seconds. • At the Ten Mile/Chinden Boulevard intersection (2 -way stop controlled), under current conditions, Ten Mile is projected to operate at LOS C or better with a delay of 18 seconds or better. At build -out of the Lochsa site, Ten Mile is projected to operate at a LOS F with a delay of 203 seconds. • All of the site access intersections operate at an acceptable level of service with acceptable vehicular delays. The intersection of McMillan Road/ Linder Road marginally meets the peak hour signal warrant for the existing no -build traffic conditions. The intersection will continue to meet the peak hour signal warrant for the 2010 build out traffic conditions. A detailed analysis will be needed when projected traffic volumes are reached before installing a signal. With or without a signal installation, the intersection needs to be improved with widening of all four approaches. • Chinden Boulevard requires center left turn lanes and right turn deceleration lanes for traffic turning into the site at both access intersections. • Linder Road requires center left turn lanes and right turn decelerations lanes for traffic turning into the site at both access intersections. • McMillan Road requires center left turn lanes for traffic turning into the site at its access intersection. McMillan Road requires right turn deceleration lane for traffic turning into the site at the roadway intersection. • Linder Road, McMillan Road, and Ten Mile Road have adequate existing capacity to handle the traffic from Lochsa project at build out. These roads will not have adequate capacity to handle the build out of the 12 -square mile North Meridian Planning Area at 2020. Any improvements on these roadways should be based on the recommendations of the North Meridian Traffic Study. • Chinden Boulevard will nearly be at capacity to handle the traffic from the Lochsa project. Chinden Blvd. will not have adequate capacity to handle the build out of the 12 -square mile North Meridian Planning Area at 2020. Chinden Blvd. should be improved based on the recommendations for the North Meridian Area Traffic Study. The Chinden Blvd./Linder Road intersection needs to be improved with widening of all four approaches for acceptable operation. The widening should include additional through lanes on Chinden Blvd and left turn lanes on Linder Road. Additional right turn lanes are optional, but will further improve the intersection operation. Any improvements on these roadways should be based on the recommendations of the North Meridian Traffic Study. The Chinden Blvd./Ten Mile Road intersection needs to be improved with widening of the northbound approach for acceptable operation. This widening should include a left turn lane on Ten Mile Road. A detailed analysis will be needed when the projected traffic volumes are reached before installing a signal. Any improvements on these roadways should be based on the recommendations of the North Meridian Traffic Study. With or without a signal installation, Linder Road/McMillan Road intersection needs widening on all four approaches. Center left turn should be constructed at this intersection before signal installation. Any improvements on these roadways should be based on the recommendations of the North Meridian Traffic Study. The Ten Mile Road/McMillan Road intersection needs to be improved with widening of the westbound approach for acceptable operation. The widening should include an additional left turn lane on McMillan Road. Any improvements on these roadways should be based on the recommendations of the North Meridian Traffic Study. The Chinden Blvd./East Access intersection meets the peak hour signal warrant for the 2010 site build out scenario. If a right turn lane on the access approach and an acceleration lane on Chinden Blvd. are provided, the effect on the right turning traffic from the accesses can be eliminated and consequently the intersection will not meet the peak hour signal warrant. If a signal must be installed, the west access should be signalized and the traffic from the east access be diverted to the west access intersection. Most of the internal streets have daily traffic projections lower than 1000 vpd. A small segment of an internal street where the traffic projections exceed 1000 vpd is shown in Figure 7. Access to the residential lots should be designed in accordance with the ACHD's access requirements. • The capacity analysis of the roundabout shows that it has adequate capacity to accommodate the build out of the Lochsa Subdivision with an acceptable LOS, and only minor delays. Other Vicinity Developments ACRD has approved Bridgetower Subdivision in 4N 1W sections 26 and 35 for construction. Traffic from Bridgetower Subdivision is included in the background traffic. A traffic impact study published by WIS on the Bridgetower Subdivision was used to extract land use and trip generation characteristics of the development. All phases of Bridgetower are expected to be completed by 2010 and are included for background traffic purposes. ACHD had also approved Keltic Heights Subdivision in 4N 1W section 25 for construction. Traffic from Keltic Heights subdivision is included in the background traffic. A traffic study published by Dobie Engineering, Inc. on the Keltic Heights subdivision was used to extract land use and trip generation characteristics of the development. The development is expected to be fully developed by the year 2005. The build out year for this study was assumed as 2010. Only the weekday pm peak hour period between 4-6 pm was analyzed so the site impacts. The study assumes that the Ten Mile river crossing will not be complete until after 2010. 4. Site Information: The site is currently functioning as agricultural and single-family residential. 5. Description of Adjacent Surrounding Area: • North: • South: • East: • West: 5. Impacted Roadways Spur Wing Golf Course Brandt Subdivision (single-family residential) Single-family residential / agricultural Single-family residential /agricultural Chinden Boulevard Frontage: Functional Street Classification: Traffic count: Level of Service: Speed limit: Nearest intersection: Linder Road Frontage: Functional Street Classification: Traffic count: Level of Service: Speed limit: Nearest intersection: McMillan Road Frontage: Functional Street Classification: Traffic count: Level of Service: Speed limit: Nearest intersection: Ten Mile Road Frontage: Functional Street Classification: Traffic count: Level of Service: Speed limit: Nearest intersection: 1,900 -feet Principal arterial East of Ten Mile Road was 10,527 on 10-11-00 «C, / "D„ 55 Chinden Boulevard and Linder Road intersection. 2,475 -feet Minor arterial South of Chinden Boulevard was 6,182 on 6-6-00. Better than "C 50 Chinden Boulevard and Linder Road intersection. 1,340 -feet Minor arterial west of Linder Road Better than "C 1,133 on 9-13-00 50 Ten Mile Road and McMillan Road 685 Minor arterial South of Chinden Boulevard was 505 on 10-11-00 Better than "C' 50 No entrances onto en Mile Road is proposed at this time (the site abutting Ten Mile will be the City Park) and the site is not near an intersection. 6. Roadway Improvements Adjacent To and Near the Site Chinden Boulevard, Linder Road, McMillan Road and Ten Mile Road are rural street sections. ■ Chinden Boulevard is improved with 2 -traffic lanes with no curb, gutter or sidewalk. ■ Linder Road is improved with 2 -traffic lanes (24 -feet of pavement) with no curb, gutter or sidewalk abutting the site. ® McMillan Road is improved with 2 -traffic lanes (24 -feet of pavement) with no curb, gutter or sidewalk abutting the site. ■ Ten Mile Road is improved with 2 -traffic lanes (24 -feet of pavement) with no curb, gutter or sidewalk abutting the site. 7. Existing Right -of -Way Chinden Boulevard has 67 -feet of existing right-of-way (25 -feet from centerline). Linder Road has 50 -feet of right-of-way (25 -feet from centerline). McMillan Road has 50 -feet of right-of-way (25 -feet from centerline). Ten Mile Road has 50 -feet of right-of-way (25 -feet from centerline). 8. Existing Access to the Site There are no public roadways currently entering the site. 9. Site History There have been no previous applications for this site previously. 10. Five Year Work Program There are no plans within the District's Fiver Year Work Program at this time. This site is located within the North Meridian Planning area. 11. Other Development in Area/Miscellaneous Staff has recently been receiving large amounts of inquiries from developers in the northwest Meridian area. Many developers are prepared to plat entire section -miles, and have site plans developed. The preliminary plans generally include 700 to 900 residential lots, schools, office/commercial lots, and city and neighborhood parks. Some of the large developments within the North Meridian Planning area include: Bridgetower Subdivision, Keltic Heights Subdivision, Baldwin Park Subdivision and Utility Subdivision. On October 17, 2001, the Commission approved a rezone application and a sketch plat for Keltic Heights Subdivision. Keltic Heights Subdivision is proposed to be 1,522 lots. The applicant proposed 929 residential lots, 8 commercial lots and a 585 -unit multi -family subdivision on 452.16 -acres. ♦ On October 17, 2001 the Commission approved a rezone and preliminary plat application for an 8 -lot industrial subdivision on 34.6 -acres (Utility Subdivision). ♦ On November 7, 2001 the Commission approved rezone and annexation application for 370.55 acres. The Commission also approved a preliminary plat for 336 lots on 175.91 acres and conditional use approval for a total of 692 single-family residences, 59 senior housing units, 17 office lots, 10 commercial lots, and an elementary school (Bridgetower Subdivision). ♦ On February 6, 2002, the Commission approved a preliminary plat application for a 272 - lot residential subdivision on 78 -acres (Baldwin Park). ♦ On April 17, 2002, the Commission approved a preliminary pat application for a 285 -lot subdivision on 75.4 acres (Heritage Commons Subdivision). Due to the large number of inquiries in this area, staff and the development community realized that the potential for development in this area is extreme and the traffic impact studies that each individual developer was submitting did not include the major surrounding developments that are "in the works". If staff examines each development individually, the roadway system appears adequate, but when staff begins to add in a second or third large- scale development, the traffic capacities of these roadways (Ustick Road, McMillan Road, Ten Mile Road, Linder Road) reach their 2020 planning thresholds. Based on development patterns in this area, and the concern surrounding the abutting roadways, ACHD hired Washington Group to conduct a traffic impact study of the northwestern Meridian area from Ustick Road to Chinden Boulevard, and from Meridian Road to one-half mile west of Black Cat Road. One option for funding improving these roadways is the implementation of an extra -ordinary impact fee overlay district. Lochsa Falls Subdivision may also be subject to any extraordinary fees that the District may impose. The second phase of the study, the economic phase has been initiated and will focus on the cost of the improvements deemed necessary by the study, including right-of-way costs. The outcome of the economic study has provided the District with an estimate of the costs to improve the roadways in the North Meridian Planning Area to handle the traffic generated by the proposed developments in the area. This final estimated cost is not yet available, as staff is still reviewing street section options that may reduce the right-of-way costs. The following Executive Summary is from the completed North Meridian Traffic Study. It examines the improvements that are anticipated within the North Meridian Planning Area: EXECUTIVE SUMMARY OF THE NORTH MERIDIAN TRAFFIC STUDY The proposed 12 -square mile study area between US 20/26 and Ustick Road and between McDermott Road and Eagle Road (Sections 25-28, 33-36 of T4N R1 W and sections 29-32 of T4N RIE), is selected Ada County Highway District (ACRD) for anticipated development build out. The following are the principal findings and recommendations of the study: ♦ By the year 2020 the study area is anticipated to develop an additional 17,599 dwelling units, 2,744,000 sq, ft of office buildings, 1,929,000 sq.ft. of retail buildings, 12 elementary schools, 2 senior high schools, 2 junior high schools, 38,260 sq. ft of church buildings, and approximately 60 acres of park. ♦ The build out scenario of the study area is projected to generate an average daily traffic (ADT) of 276,764 vehicles per day (vpd), of which the peak hour traffic (PHT) will be 28,206 vehicles per hour (vph). Out of these trips approximately 10% of the trips remain internal within each section, and 6% of the trips are pass -by trips. ♦ The distribution of the traffic from all of the study area sections indicate that approximately 30% traffic directed towards south, 27% of the traffic directed towards east, 21% of the traffic directed towards west and north. The remaining 22% of the traffic is distributed within the study area. ♦ At build out, traffic on the arterials is expected to significantly increase (see Table 4). ♦ All of the arterial intersections in the study area are currently operating at acceptable level of service of "C" or better. ♦ By the year 2020, the majority of study intersections are projected to meet the peak hour traffic signal warrant. A proportionate share of the impacts of the individual sections at each of the study area arterial intersections is summarized in Table 6. o Several mid -mile intersections may warrant traffic signals due to the heavy left turn traffic volume. ♦ Chinden Boulevard is forecasted with 5 -lane section in the study area. Right turns lanes may be required at some access and arterial intersections. ♦ McMillan Road is forecasted with a 5 -lane section east of Black Cat. McMillan Road is forecasted with a 3 -lane section west of Black Cat. At arterial intersections and at access intersections right turns lanes may be necessary. ♦ Ustick Road is forecasted with a 5 -lane section east of Black Cat. Ustick Road is forecasted with a 3 -lane section west of Black Cat. At arterial intersections and at access intersections right turns lanes may be necessary. ♦ Linder Road forecasted with a 5 -lane section in the study area. At arterial intersections and at access intersections right turns lanes may be required. ♦ McDermott Road is forecasted with a 3 -lane section in the study area. At arterial intersections and at access intersections turn lanes may be required. ♦ Black Cat Road is forecasted with a 3 -lane section in the study area. At arterial intersections right turn lanes may be required. ♦ Ten Mile Road is forecasted with a 5 -lane section in the study area. At arterial intersections and at access intersections turn lanes may be required. ♦ Meridian Road requires a 3 -lane section north of McMillan and 5 -lane section south of McMillan in the study area. At arterial intersections right turn lanes may be required. ♦ Locust Grove Road requires a 3 -lane section in the study area. At arterial intersections right turn lanes may be required. At Ustick Road a 5 -lane section is forecasted. N Staff recognizes that the amount of right-of-way dedicated with these improvements is overwhelming, and that ACHD may not have the funds to purchase such a large amount of right-of-way. In this situation it is likely that impact fee offset agreements will be utilized to offset the amount of money that ACHD will pay out-of-pocket to acquire the right-of- way. B. Findings for Consideration 1. Future Parcels The applicant has included three lots that will be required to submit a conditional use application or a design review application in the future. The lots include the proposed fire station, the proposed City Park and the proposed multi -family lot located on North Goddard Creek Way. Once a formal application has been submitted for the proposed parcels, the District will approve driveway locations in accordance with District policy. Due to the fact that these parcels are a part of the plat, the District will acquire right-of-way and roadway improvements to the parcels. 2. Right -of -Way District policy requires 96 -feet of right-of-way on arterial roadways (Figure 72-F1 B). This right- of-way allows for the construction of a 5 -lane roadway with curb, gutter, 5 -foot concrete detached sidewalks and bike lanes. The applicant should dedicate 48 -feet of right-of-way from the centerline of Linder Road, Ten Mile Road and McMillan Road abutting the parcel by means of a warranty deed. The right-of- way purchase and sale agreement and deed must be completed and signed by the applicant prior to scheduling the final plat for signature by the ACHD Commission or prior to issuance of a building permit (or other required permits), whichever occurs first. Allow up to 30 business days to process the right-of-way dedication after receipt of all requested material. The owner will be paid the fair market value of the right-of-way dedicated which is an addition to existing ACHD right-of-way if the owner submits a letter of application to the impact fee administrator prior to breaking ground, in accordance with ACHD Ordinance #195. The applicant has expressed an interest in dedicating less right-of-way (38 -feet from centerline) and placing the sidewalk on Linder Road Ten Mile Road and McMillan Road within an easement. The District is supportive of the applicant dedicating the amount of right-of-way that is required for the construction of the roadway due to the fact that the District may construct the roadway without having to compensate the applicant for additional right-of-way. The applicant should dedicate an adequate amount of right-of-way (38 -feet from centerline) that can accommodate one half of a 72 -foot street section with curb, gutter and a 2 -foot utility easement with an easement for the 5 -foot concrete sidewalk. On August 28, 2002, the Commission voted to approve the above requested modification. State Highway 20/26 is under the jurisdiction of ITD. The applicant should contact ITD to determine if any right-of-way will be acquired in association with this development. 19 3. Sidewalk District policy requires 5 -foot wide (minimum) concrete sidewalk on all collector roadways and arterial roadways (7204.6.5). The applicant should construct 5 -foot concrete sidewalk abutting the property on McMillan Road; Ten Mile Road and Linder Road. The sidewalk should be constructed 2 -feet within the new right-of-way. If the sidewalk is proposed to meander of outside of the right-of-way, the applicant should provide an easement to the District. 4. Main Entrances District policy 7204.11.5, requires collector roadways to align or offset a minimum of 1,300 -feet from an arterial to allow for adequate spacing between signals. District policy 7204.11.6, requires residential collector roadways to align or offset a minimum of 300 -feet from any proposed or existing roadway. The applicant is proposing to construct a main entrance, North Goddard Creek Way, to intersect McMillan Road approximately 1,100 -feet east of the west property line (approximately at the half -mile). The applicant is proposing to construct this roadway as a collector roadway. The applicant is proposing to construct a main entrance, West Cayuse Creek Drive, to intersect Linder Road located approximately 1,350 -feet north of the south property line (approximately the half -mile). The applicant is proposing to construct this roadway as a collector roadway. The applicant is proposing to construct a main entrance, Wild Goose Drive, to intersect Linder Road at the south property line. The applicant is proposing to construct this roadway as a residential collector. The proposed locations of North Goddard Creek Way, West Cayuse Creek Drive and Wild Goose Drive meet District policy and should be approved with this application. The applicant is proposing to construct a main entrance, North Lochsa Way, to intersect with Chinden Boulevard (State Highway 20/26) located at the west property line (approximately the half -mile). The applicant is proposing to construct a main entrance, North Dry Bar Avenue, to intersect with Chinden Boulevard (State Highway 20/26) located approximately 750 -feet west of the east property line. Chinden Boulevard is under the jurisdiction of ITD, the applicant should contact ITD regarding the location and the future signalization North Lochsa Way and North Dry Bar Avenue, 5. Center Turn Lanes and Pavement Tapers District policy 3004.1, 72-F8, AASHTO guidelines and the MUTCD guidelines require the turn lane to be constructed to provide a minimum of 100 -feet of storage with shadow tapers for both the approach and departure directions. Coordinate the design of the turn lane with District staff. 11 District policy 3004.1 and AASHTO Guidelines require tapers to be constructed on a varying basis contingent upon the posted speed limit. Coordinate the design of the taper with District staff. The submitted Traffic Impact Study shows that the traffic generated by the site requires the construction of center turn lanes and right -turn deceleration lanes (tapers) on Linder Road for West Cayuse Creek Drive and West Wild Goose Drive. The submitted Traffic Impact Study shows that the traffic generated by the site requires the construction of center turn lanes and right -turn deceleration lanes (tapers) on McMillan Road for North Goddard Creek Way. The applicant should construct a center turn lane on Linder Road for West Cayuse Creek Drive to provide a minimum of 100 -feet of storage with shadow tapers for both the approach and departure directions. Coordinate the design of the turn lane with District staff. The applicant should construct a center turn lane on Linder Road for West Wild Goose Drive to provide a minimum of 100 -feet of storage with shadow tapers for both the approach and departure directions. Coordinate the design of the turn lane with District staff. The applicant should construct a center turn lane on McMillan Road for North Goddard Creek Way to provide a minimum of 100 -feet of storage with shadow tapers for both the approach and departure directions. Coordinate the design of the turn lane with District staff. The applicant should construct right -turn deceleration lanes (tapers) on Linder Road for West Cayuse Creek Drive and West Wild Goose Drive. Coordinate the design of the taper with District staff. The applicant should construct right -turn deceleration lanes (tapers) on McMillan Road for North Goddard Creek Way. Coordinate the design of the taper with District staff. 6. Street Sections Internal local residential roadways District policy 72 -FIA, allows local residential public roads with a 33 -foot street section with parking on both sides of the roadway, if the amount of vehicle trips per day on the street does not exceed 1,000 and the appropriate fire department (Meridian Fire Department) reviews and approves the street section. The proposed density of development that will utilize the internal local residential streets is anticipated to generate less than 1,000 vehicle trips per day. The applicant is proposing to construct all of the internal local residential streets as 33 -foot street sections with 4 -foot detached sidewalks. 12 The applicant should construct the internal local residential roadways as a 33 -foot street with curb, gutter and 4 -foot wide detached concrete sidewalk within 50 -feet of right-of-way with parking on both sides of the roadway contingent upon approval from the Meridian Fire Department. Internal commercial / Industrial roadways District policy 7202.8 and 72-F1 B, requires roadways abutting commercial developments to be constructed as a 40 -foot street section with curb, gutter and 5 -foot concrete sidewalk within 54 - feet of right-of-way. The applicant is proposing to construct North Dry Bar Avenue as a 33 -foot street section with curb, gutter and 5 -foot concrete sidewalk within 50 -feet of right-of-way. The applicant should construct North Dry Bar Avenue as a 40 -foot street section with curb, gutter and 5 -foot concrete sidewalk within 54 -feet of right-of-way abutting the commercial development (approximately 350 -feet). Internal residential collector roadways The applicant is proposing to construct West Ballinger Way (the entire length — 150 -feet) and West Wild Goose Drive (Linder Road extending west for approximately 470 -feet) as residential collector streets with no front -on housing, because the anticipated traffic volumes exceed 1,000 vehicle trips per day. District policy 72 -FIA, 7202.3.2 and 7202.3.5, requires that residential collectors be constructed as 36 -foot street sections with curb, gutter and 5 -foot wide concrete sidewalks with no front -on housing. The access restrictions for these street segments should be stated on the final plat. Unless otherwise noted, parking should be prohibited on these street segments. Coordinate the signage plan with District staff. West Ballinger Way and West Wild Goose Drive should be constructed as 36 -foot street sections with curb, gutter and 5 -foot wide concrete sidewalks with no front -on housing. The access restrictions for these street segments should be stated on the final plat. Parking should be prohibited on these street segments. Coordinate the signage plan with District staff. Internal collector roadways District policy 72-FlA allows collector roadways with 29 -foot street sections with vertical curb, gutter and 5 -foot concrete sidewalk within 50 -feet of right-of-way with parking prohibited on both sides of the roadway. The applicant has inquired about a collector roadway street section that includes bike lanes. Staff has concluded that a 33 -foot street section can accommodate two 1( - foot traffic lanes and two 4 -foot bike lanes. The submitted Traffic Impact study determined that West Cayuse Creek Drive, North Goddard Creek Way and North Lochsa Way (the proposed collector roadways) are warranted by this development. The traffic study also noted that the mid -mile collector warrants for a connection onto Ten Mile Road were not met. 13 The applicant is proposing to construct the collector roadways (West Cayuse Creek Drive, North Goddard Creek Way, North Lochsa Way) within the site as 33 -foot street section with curb, gutter and 5 -foot concrete sidewalk within 50 -feet of right-of-way. The applicant has proposed to construct a 10 -foot wide asphalt pathway on the south side of Cayuse Creek Drive extending from Linder Road to the roundabout in lieu of 5 -foot concrete sidewalk on both sides of the roadway. The applicant has proposed to construct pedestrian crossings (constructed out of brick pavers) to provide pedestrians the opportunity to move from the north side of the development to the asphalt pathway on Cayuse Creek Drive. The proposed pedestrian crossings are proposed to be located at the Moose Creek Street and Cayuse Creek Drive intersection, Dry Bar Way and Cayuse Creek Drive intersection and Fish Creek Court and Cayuse Creek Drive intersection. This design is consistent with past Commission action and is approved with this application. The applicant must provide an easement for the pathway and the pathway must be owned and maintained by the Homeowners Association. 7. Driveways District policy F2 -F5, requires driveways located on collector or arterial roadways with a speed limit of 50 to align or offset a minimum of 255 -feet from any existing or proposed driveway. District policy 72-F4 (2) requires driveways on commercial 1 industrial roadways to offset any existing or proposed street intersection a minimum of 50 -feet. The applicant is proposing to construct two shared driveways intersecting McMillan Road. • The first driveway location is proposed to be located on McMillan Road approximately 250 -feet east of the west property line. • The second driveway location is proposed to be located on McMillan Road approximately 725 -feet east of the west property line. The applicant is proposing to construct a 25 -foot shared access driveway intersecting North Goddard Creek Way. The driveway location is proposed to be located approximately 420 -feet north of McMillan Road extending to the west property line. The 30 -foot wide driveway that is proposed to be located on McMillan Road approximately 250 - feet east of the west property line meets District policy and should be approved with this application. The 30 -foot wide driveway that is proposed to be located on McMillan Road approximately 725 - feet east of the west property line meets District policy and should be approved with this application. 14 The 25 -foot driveway that is proposed to be located on North Goddard Creek Way approximately 42 -feet north of McMillan Road extending to the west property line meets District policy and should be approved with this application. The applicant is proposing to construct two shared driveways that are proposed to intersect with North Dry Bar Avenue approximately 350 -feet south of Chinden Boulevard. The two driveways are proposed to align with one another with one extending east from North Dry Bar Avenue and the other extending west from North Dry Bar Avenue. The two proposed 25 -foot shared driveways that intersect North Dry Bar Avenue approximately 350 -feet south of Chinden Boulevard meet District policy and should be approved with this application. Graveled driveways abutting public streets create maintenance problems due to gravel being tracked onto the roadway. In accordance with District policy, 7207.9.1, the applicant should be required to pave the driveway its full width and at least 30 -feet into the site beyond the edge of pavement of all abutting roadways and install pavement tapers with 15 -foot radii abutting the existing roadway edge. 8. Roadway Offsets District policy 7204.11.6, requires local roadways to align or offset a minimum of 125 -feet from another local roadway (measured centerline to centerline). District policy 7204.11.6, requires local roadways to align or offset a minimum of 150 -feet from a residential collector roadway (measured centerline to centerline). District policy 7204.11.6, requires local roadways to align or offset a minimum of 150 -feet from a collector roadway (measured centerline to centerline). District policy 7204.11.6, requires residential collector roadway to align or offset a minimum of 200 -feet from a collector roadway (measured centerline to centerline). District policy 7204.11.6, requires residential collector roadway to align or offset a minimum of 200 -feet from a collector roadway (measured centerline to centerline). 9. Stub Streets District policy 7203.5.1 and 7205.5 requires stub streets to provide intra -neighborhood circulation and to provide access to adjoining parcels. District policy also requires temporary turnarounds with a temporary easement provided to the District at the end of stub streets that serve more than one lot, or are greater than 150 -feet in length with a sign at the terminus of the roadway stating that, "THIS ROAD WILL BE EXTENDED IN THE FUTURE". The applicant is proposing to construct thirteen stub streets to the surrounding parcels. 15 • The applicant is proposing to construct West Apgar Drive to the east property line approximately 400 -feet north of McMillan Road. • The applicant is proposing to construct West Wapoot Court to the east property line approximately 1,100 -feet north of McMillan Road. • The applicant is proposing to construct Parachute Hill Avenue to the south property line approximately 600 -feet east of the west property line. • The applicant is proposing to construct North Chimney Peak Avenue to the south property line approximately 1,650 -feet east of the west property line. • The applicant is proposing to construct West Cedar Grove Street to the east property line approximately 650 -feet north of the south property line. • The applicant is proposing to construct North Gertie Place to the north property line approximately 100 -feet west of the east property line. • The applicant is proposing to construct West Boulder Bar Street to the west property line approximately 500 -feet south of Chinden Boulevard. • The applicant is proposing to construct West Tango Creek Street to the west property line approximately 1,025 -feet south of Chinden Boulevard. • The applicant is proposing to construct North Powell Creek Avenue to the north property line approximately 2,050 feet east of the west property line. • The applicant is proposing to construct West Glade Creek Street to the west property line approximately 1,500 -feet south of Chinden Boulevard. • The applicant is proposing to construct West Anatole Street to the west property line approximately 2,350 -feet north of McMillan Road. • The applicant is proposing to construct West Whitehouse Street to the west property line approximately 1,800 -feet north of McMillan Road. • The applicant is proposing to construct West Divide Creek Street to the west property line approximately 1,025 -feet north of McMillan Road. The applicant should construct thirteen stub streets, as proposed. The applicant should be required to provide a paved temporary turnaround with a temporary easement provided to the District at the end North Gertie Place, West Glade Creek Street and West Wapoot Court with a sign at the terminus of the roadway stating that, 'THIS ROAD WILL BE EXTENDED IN THE FUTURE". Coordinate the sign plan for the stub street, and the design of the turnaround with District staff. 10.Islands District policy 7202.7 and 7207.5 requires any proposed landscape islands/medians within the public right-of-way dedicated by this plat should be owned and maintained by a homeowners association. Notes of this should be required on the final plat. The applicant is proposing to construct several islands throughout the subdivision. 11. Knuckles District policy District policy 7202.7 and 7207.5 and the local Fire District standards require an island within a knuckle to be constructed with the island being a minimum of 4 -feet wide with a minimum area of 100 -square feet and designed to safely channel traffic. The roadway around 16 the traffic island should maintain a minimum of a 29 -foot street section. The design should be reviewed and approved by ACHD's Planning and Development staff. The applicant is proposing to construct one knuckle on North Goddard Creek Way located approximately 700 -feet north of McMillan Road. The proposed knuckle on North Goddard Creek Way located approximately 700 -feet north of McMillan Road meets District policy and should be approved with this application. 12. Roundabouts District policy District policy 7202.7 and 7207.5 and the local Fire District standards require that roundabouts be designed with 21 -foot street sections on either side of the center island. The applicant will be required to dedicate the roadway right-of-way plus the additional width of the island. Coordinate the size and design of the roundabout with traffic services staff. The applicant is proposing to construct a round about at the intersection of North Locsa Way, North Goddard Creek Way and West Cayuse Creek Way as a traffic calming measure and as an amenity to the subdivision. 13. Cul-de-sacs District policy 7205.2.1 requires turnarounds to be constructed to provide a minimum turning radius of 45 -feet. The applicant should also be required to provide a minimum of a 29 -foot street section on either side of any proposed center islands within the turnarounds. The medians should be constructed a minimum of 4 -feet wide to total a minimum of a 100 -square foot area. Dedicate 54 -feet of right-of-way plus the additional width of the median. The applicant is proposing to construct several cul-de-sac turnarounds throughout the subdivision. 14. Special Recommendation to the City The applicant is proposing to provide access to the out parcel via a driveway off of West Wapoot Court. The out parcel should be required to take access of the internal roadway system as opposed to continuing to access McMillan Road. 15. Special Recommendation to the Applicant In order to reduce trips to and from the residential portion of this development, it is recommended that upon occupancy the Home Owners Association provide new residents with information on alternative transportation and the commute options available. Commuteride staff will coordinate this effort with the applicant. For more information contact Ms. Catherine Sanchez at 387-6162. It is also recommended that the applicant cooperate with Valley Inter -area Transportation to preserve the right-of-way for future bus shelters and a bus pull-out at Block 20, Lot I. For more information contact Mr. Kevin Bittner at 846-8547. 17 In order to reduce trips to and from the commercial portion of this development, it is recommended that the applicant dedicate at least 10 parking spots to be used as a Park and Ride, lot. It is recommended the site be located near the North Chinden entrance adjoining Block 55, Lot 22. It is also recommended the applicant consider providing bicycle facilities at both proposed office space locations. It is recommended that tenants occupying the proposed buildings be required to provide an Alternative Transportation Program for employees prior to issuance of a building permit. The applicant shall provide an annual report to ACHD Commuteride on program participation. Commuteride staff will coordinate the Alternative Transportation Program with the applicant. For more information contact Ms. Catherine Sanchez at 387-6162. C. Site Specific Conditions of Approval Dedicate 48 -feet of right-of-way from the centerline of Linder Road, Ten Mile Road and McMillan Road abutting the parcel by means of a warranty deed. The right-of-way purchase and sale agreement and deed must be completed and signed by the applicant prior to scheduling the final plat for signature by the ACHD Commission or prior to issuance of a building permit (or other required permits), whichever occurs first. Allow up to 30 business days to process the right-of- way dedication after receipt of all requested material. The owner will be paid the fair market value of the right-of-way dedicated which is an addition to existing ACHD right-of-way if the owner submits a letter of application to the impact fee administrator prior to breaking ground, in accordance with ACHD Ordinance #195. OR Dedicate 38 -feet of right-of-way from the centerline of Linder Road, Ten Mile Road and McMillan Road abutting the parcel by means of a warranty deed. The right-of-way purchase and sale agreement and deed must be completed and signed by the applicant prior to scheduling the final plat for signature by the ACHD Commission or prior to issuance of a building permit (or other required permits), whichever occurs first. Allow up to 30 business days to process the right-of- way dedication after receipt of all requested material. The owner will be paid the fair market value of the right-of-way dedicated which is an addition to existing ACHD right-of-way if the owner submits a letter of application to the impact fee administrator prior to breaking ground, in accordance with the ACHD Ordinance in effect at that time (currently Ordinance #195). 2. Construct 5 -foot concrete sidewalk abutting the property on McMillan Road, Ten Mile Road and Linder Road. The sidewalk shall be constructed 2 -feet within the new right-of-way. If the sidewalk is proposed to meander of outside of the right-of-way, the applicant shall provide an easement to the District. 3. Construct a main entrance, North Goddard Creek Way, to intersect McMillan Road approximately 1,100 -feet east of the west property line (approximately at the half -mile). 4. Construct a main entrance, West Cayuse Creek Drive, to intersect Linder Road located approximately 1,350 -feet north of the south property line (approximately the half -mile). IN 5. Construct a main entrance, Wild Goose Drive, to intersect Linder Road at the south property line. Construct a center turn lane on Linder Road for West Cayuse Creek Drive to provide a minimum of 100 -feet of storage with shadow tapers for both the approach and departure directions. Coordinate the design of the turn lane with District staff. 7. Construct a center turn lane on Linder Road for West Wild Goose Drive to provide a minimum of 100 -feet of storage with shadow tapers for both the approach and departure directions. Coordinate the design of the turn lane with District staff. 8. Construct a center turn lane on McMillan Road for North Goddard Creek Way to provide a minimum of 100 -feet of storage with shadow tapers for both the approach and departure directions. Coordinate the design of the turn lane with District staff. 9. Construct right -turn deceleration lanes (tapers) on Linder Road for West Cayuse Creek Drive and West Wild Goose Drive. Coordinate the design of the taper with District staff. 10. Construct right -turn deceleration lanes (tapers) on McMillan Road for North Goddard Creek Way. Coordinate the design of the taper with District staff. 11. Construct the internal local residential roadways as a 33 -foot street with curb, gutter and 4 -foot wide detached concrete sidewalk within 50 -feet of right-of-way with parking on both sides of the roadway contingent upon approval from the Meridian Fire Department. 12. Construct North Dry Bar Avenue as a 40 -foot street section with curb, gutter and 5 -foot concrete sidewalk within 54 -feet of right-of-way abutting the commercial development (approximately 350 - feet). 13. Construct West Ballinger Way and West Wild Goose Drive as 36 -foot street sections with curb, gutter and 5 -foot wide concrete sidewalks with no front -on housing. The access restrictions for these street segments shall be stated on the final plat. Parking shall be prohibited on these street segments. Coordinate the signage plan with District staff. 14. Construct West Cayuse Creek Drive, North Goddard Creek Way, North Lochsa Way a 33 -foot street section with a 4 -foot bike lane, curb, gutter and 5 -foot concrete sidewalk within 50 -feet of right-of-way. Submit written approval from the Meridian Fire Department. (Per the Commission action of May 22, 2002, the applicant may construct an alternative street section with a pathway on Cayuse Creek Drive, with staff approval. Please see item number 6 on pages 13 and 14.) 15. Construct a 30 -foot wide driveway located on McMillan Road approximately 250 -feet east of the west property line meets District policy and should be approved with this application. 16. Construct a 25 -foot shared access driveway intersecting North Goddard Creek Way approximately 420 -feet north of McMillan Road extending to the west property line. 19 17. Construct two shared driveways (one extending east; one extending west) located on North Dry Bar Avenue approximately 350 -feet south of Chinden Boulevard. 18. Construct thirteen stub streets to the surrounding parcels. • The applicant is proposing to construct West Apgar Drive to the east property line approximately 400 -feet north of McMillan Road. • The applicant is proposing to construct West Wapoot Court to the east property line approximately 1,100 -feet north of McMillan Road. • The applicant is proposing to construct Parachute Hill Avenue to the south property line approximately 600 -feet east of the west property line. • The applicant is proposing to construct North Chimney Peak Avenue to the south property line approximately 1,650 -feet east of the west property line. • The applicant is proposing to construct West Cedar Grove Street to the east property line approximately 650 -feet north of the south property line. • The applicant is proposing to construct North Gertie Place to the north property line approximately 100 -feet west of the east property line. • The applicant is proposing to construct West Boulder Bar Street to the west property line approximately 500 -feet south of Chinden Boulevard. • The applicant is proposing to construct West Tango Creek Street to the west property line approximately 1,025 -feet south of Chinden Boulevard. • The applicant is proposing to construct North Powell Creek Avenue to the north property line approximately 2,050 feet east of the west property line. • The applicant is proposing to construct West Glade Creek Street to the west property line approximately 1,500 -feet south of Chinden Boulevard. • The applicant is proposing to construct West Anatole Street to the west property line approximately 2,350 -feet north of McMillan Road. • The applicant is proposing to construct West Whitehouse Street to the west property line approximately 1,800 -feet north of McMillan Road. • The applicant is proposing to construct West Divide Creek Street to the west property line approximately 1,025 -feet north of McMillan Road. 19. Provide a paved temporary turnaround with a temporary easement provided to the District at the end North Gertie Place, West Glade Creek Street and West Wapoot Court and a sign at the terminus of all of the stub streets stating that, "THIS ROAD WILL BE EXTENDED IN THE FUTURE". Coordinate the sign plan for the stub street, and the design of the turnaround with District staff. 20. Any proposed landscape islands/medians within the public right-of-way dedicated by this plat shall be owned and maintained by a homeowners association. Notes of this are required on the final plat. 21. Construct one knuckle on North Goddard Creek Way located approximately 700 -feet north of McMillan Road. The island within the knuckle shall be constructed a minimum of 4 -feet wide with a minimum area of 100 -square feet and designed to safely channel traffic. The roadway around the traffic island shall maintain a minimum of a 29 -foot street section. The design shall be reviewed and approved by ACHD's Planning and Development staff. 20 22. Construct a round about at the intersection of North Locsa Way, North Goddard Creek Way and West Cayuse Creek Way with 21 -foot street sections on either side of the center island. Coordinate the size and design of the roundabout with traffic services staff. 23.Turnarounds shall be constructed to provide a minimum turning radius of 45 -feet. The applicant will be required to provide a minimum of a 29 -foot street section on either side of any proposed center islands within the turnarounds. The medians shall be constructed a minimum of 4 -feet wide to total a minimum of a 100 -square foot area. Dedicate 54 -feet of right-of-way plus the additional width of the median. 24. The applicant shall enter into a development agreement with ACHD that outlines right-of-way acquisition, costs, timing and payment; and shall also include an agreement that this development shall be subject to any extraordinary impact fee, LID or other funding source established by the District to improve the surrounding roadways; or shall be subject to the development's proportionate share of surrounding roadway improvements as established by the applicant's traffic impact study. 25. Comply with requirements of ITD for State Highway 20/26 (Chinden Boulevard) frontage. Submit to the District a letter from ITD regarding said requirements prior to District approval of the final plat or issuance of a building permit (or other required permits), whichever occurs first. Contact District III Traffic Engineer Michael Garz at 334-8340. D. Standard Conditions of Approval Any existing irrigation facilities shall be relocated outside of the right-of-way. 2. All utility relocation costs associated with improving street frontages abutting the site shall be borne by the developer. 3. Replace any existing damaged curb, gutter and sidewalk and any that may be damaged during the construction of the proposed development. Contact Construction Services at 387- 6280 (with file number) for details. 4. All design and construction shall be in accordance with the Ada County Highway District Policy Manual, ISPWC Standards and approved supplements, Construction Services procedures and all applicable ACHD Ordinances unless specifically waived herein. An engineer registered in the State of Idaho shall prepare and certify all improvement plans. 5. The applicant shall submit revised plans for staff approval, prior to issuance of building permit (or other required permits), which incorporates any required design changes. 6. Construction, use and property development shall be in conformance with all applicable requirements of the Ada County Highway District prior to District approval for occupancy. 21 Payment of applicable road impact fees are required prior to building construction in accordance with Ordinance #195, also known as Ada County Highway District Road Impact Fee Ordinance. It is the responsibility of the applicant to verify all existing utilities within the right-of-way. Existing utilities damaged by the applicant shall be repaired by the applicant at no cost to ACRD. The applicant shall be required to call DIGLINE (1-800-342-1585) at least two full business days prior to breaking ground within ACHD right-of-way. The applicant shall contact ACHD Traffic Operations 387-6190 in the event any ACHD conduits (spare or filled) are compromised during any phase of construction. 9. No change in the terms and conditions of this approval shall be valid unless they are in writing and signed by the applicant or the applicant's authorized representative and an authorized representative of the Ada County Highway District. The burden shall be upon the applicant to obtain written confirmation of any change from the Ada County Highway District. 10. Any change by the applicant in the planned use of the property which is the subject of this application, shall require the applicant to comply with all rules, regulations, ordinances, plans, or other regulatory and legal restrictions in force at the time the applicant or its successors in interest advises the Highway District of its intent to change the planned use of the subject property unless a waiver/variance of said requirements or other legal relief is granted pursuant to the law in effect at the time the change in use is sought. Conclusions of Law The proposed site plan is approved, if all of the Site Specific and Standard Conditions of Approval are satisfied. 2. ACHD requirements are intended to assure that the proposed use/development will not place an undue burden on the existing vehicular and pedestrian transportation system within the vicinity impacted by the proposed development. Attachments 1. Vicinity map 2. Submitted site plan 22 Request for Reconsideration of Commission Action 1. Request for Reconsideration of Commission Action: A Commissioner, a member of ACHD staff or any other person objecting to any final action taken by the Commission may request reconsideration of that action, provided the request is not for a reconsideration of an action previously requested to be reconsidered, an action whose provisions have been partly and materially carried out, or an action that has created a contractual relationship with third parties. a. Only a Commission member who voted with the prevailing side can move for reconsideration, but the motion may be seconded by any Commissioner and is voted on by all Commissioners present. If a motion to reconsider is made and seconded it is subject to a motion to postpone to a certain time. b. The request must be in writing and delivered to the Secretary of the Highway District no later than 3:00 p.m. on the day prior to the Commission's next scheduled regular meeting following the meeting at which the action to be reconsidered was taken. Upon receipt of the request, the Secretary shall cause the same to be placed on the agenda for that next scheduled regular Commission meeting. c. The request for reconsideration must be supported by written documentation setting forth new facts and information not presented at the earlier meeting, or a changed situation that has developed since the taking of the earlier vote, or information establishing an error of fact or law in the earlier action. The request may also be supported by oral testimony at the meeting. d. If a motion to reconsider passes, the effect is the original matter is in the exact position it occupied the moment before it was voted on originally. It will normally be returned to ACHD staff for further review. The Commission may set the date of the meeting at which the matter is to be returned. The Commission shall only take action on the original matter at a meeting where the agenda notice so provides. e. At the meeting where the original matter is again on the agenda for Commission action, interested persons and ACHD staff may present such written and oral testimony as the President of the Commission determines to be appropriate, and the Commission may take any action the majority of the Commission deems advisable. f. If a motion to reconsider passes, the applicant may be charged a reasonable fee, to cover administrative costs, as established by the Commission. 23 LOCHSA FALLS SUBDIVISION 862 single-family dwellings, 171 multi -family dwellings, 11 office buildings, 1 commercial building, 1 fire station, 1 city park and 1 private park. 24 04-20—'06 15:20 FROM—SSC — — — ---- ---------- 2088885052 T-921 P002/003 F-994 � 1 N. LAZA LAKE *0 I I I ,iv si I pry uYGYY®lIa ii IOCNSA FALIS OFFICE PARK i' �91 BUILDING It cif �Bp4�♦W1iMHp9RM1�KH�4 >I k 19 04-20-'06 15:20 FROM -SSC 2088885052 T-921 P003/003 F-994 tl �. T z r 3 p ru "r .I tl �. IIIWrrw�.. v��gaa 60/60 39Vd 031ISVH 00068F680Z 56:11 900Z(61/t0 w t4 Uctld il)r r Planning Department CERTIFICATE OF ZONING COMPLIANCE Application Checklist Project name: p File Applicantla ent: M P All applications are required to contain one copy of the following unless otherwise noted: .Applicant Description Staff Completed & signed Administrative Review Application c ---- Narrative fully describing the proposed use of the property, including the following: ➢ Information on any previous approvals or requirements for the requested use i.e..a licableconditions q`--' — D-men[Agreemen[ Recorded warranty deed for the subject propeq Affidavit of Legal Interest signed & notarized by the property owner (if owner is acorporation submit a copy of the Articles of Incorpomtion or other evidence to show that the pemn signing is an authorized agent. Scaled vicinity map showing the location of the subject property / Sanitary Service Company approval for trash enclosure & access drive (stamped site plan) -----� A photometric test report for any light fixture(s) with a maximum output of 1,800 lumens or more see UDC 11 -3A -t I Site Plan -4 copies (folded to 8 %2" x I I" size) The following items must be shown on the siteplan: • Date, scale, north arrow, and project name (scale not less than P'=50') • Names, addresses, and telephone numbers of the developer and the person and/or firm preparing the plan • Parking stalls and drive aisles • Trash enclosure(s) location • Detail of trash enclosure (must be screened on 3 sides) • Location and specifications for underground irrigation (Pressurized irrigation can only be / waived if you prove no water rights exist to subject ro • Sidewalks or pathways (proposed and existing) / • Location of proposed building on lot (include dimensions to propertlines) / • Fencing (proposed and existing) • Calculations table including the following: Number of parking stalls required & provided (specify handicap & compact stalls) ➢ Building size (sq. a.) ➢ Lot size (sq. 8.) ➢ Setbacks ➢ Zoning district / Reduction of the site plan 8 %2" x 11 ") Landscape plan — 3 copies (folded to 8 W' x 1 l" size) Plan most have a scale no smaller than l " = 50'(1 " = 20' is preferred) and be on a standard drawing sheet, not to exceed 36"x 48" (24"x 36" is preferred). A plan which cannot be drmvn in its entirety on a single sheet mast be drmvn will; appropriate match lines on hvo or more sheets. The following items must be included on the landscapeplan: • Date, scale, north arrow, and project name • Names, addresses, and telephone numbers of the developer and the person and/or firm preparing the plan 660 E. Watertower Lane, Suite 202 • Meridian, Idaho 83642 Phone: (208) 884-5533 • Facsimile: (208) 888-6854 • Website: www.meridiancity.org ACRD Acceptance: Applicant shall be responsible for meeting the requirements ofACHD as they pertain to this application. All impact fees, if any, shall be paid prior to the issuance ofa buildingpermit. Ifany changes must be made to the site plan to accommodate the ACHD requirements, a new site plan shall be submitted to the City of Meridian Planning & Zoning Department for approval prior to the issuance ofa building permit. Your• building permit will not be issued until ACHD has approved your• plans and all associated fees have been paid THIS APPLICATION SHALL NOT BE CONSIDERED COMPLETE UNTIL STAFF HAS RECEIVED ALL REQUIRED INFORMATION • Existing natural features such as canals, creeks, drains, ponds, wetlands, flood tains, high groundwater areas, and rock outcroppings. • Location, size, and species of all existing trees on site with trunks 4 inches or greater in diameter, measured 6 inches above the ground. Indicate whether the tree will be retained or removed. • A statement of how existing healthy trees proposed to be retained will be protected from damage during construction • Existing structures, planting areas, light poles, power poles, walls, fences, berms, parking and loading areas, vehicular drives, trash areas, sidewalks, pathways, stormwater detention areas, signs, street furniture, and other man-made elements. • Existing and proposed contours for all areas steeper than 20% slope. Berms shall be shown with one -foot contours. • Sight Triangles as defined in I1 -3A-5 of this ordinance. • Location and labels for all proposed plants, including trees, shrubs, and groundcovers (trees must not be planted in City water or sewer easements). Scale shown for plant materials shall reflect approximate mature size • A plant list that shows the plant symbol, quantity, botanical name, common name, minimum planting size and container, tree class (I, 11, or IB), and comments (for spacing, staking, and installation as appropriate). • Planting and installation details as necessary to ensure conformance with all required standards. ' • Design drawing(s) of all fencing proposed for screening purposes ® Calculations of project components to demonstrate compliance with the requirements of this ordinance, including: ➢ Number of street trees and lineal feet of street frontage ➢ Width of street buffers (exclusive of right-of-way) ➢ Width of parking lot perimeter landscape strip ➢ Buffer width between different land uses (if applicable) ➢ Number of parking stalls and percent of parking area with internal landscaping ➢ Total number of trees and tree species mix ➢ Mitigation for removal of existing trees, including number of caliper inches being removed Reduction of the landscape plan 8 Y2" x 11" Building elevations showing construction materials i Fee If this project had prior aDproval on a site plan, reduced fees may apply) ACRD Acceptance: Applicant shall be responsible for meeting the requirements ofACHD as they pertain to this application. All impact fees, if any, shall be paid prior to the issuance ofa buildingpermit. Ifany changes must be made to the site plan to accommodate the ACHD requirements, a new site plan shall be submitted to the City of Meridian Planning & Zoning Department for approval prior to the issuance ofa building permit. Your• building permit will not be issued until ACHD has approved your• plans and all associated fees have been paid THIS APPLICATION SHALL NOT BE CONSIDERED COMPLETE UNTIL STAFF HAS RECEIVED ALL REQUIRED INFORMATION PLANNING & ZONING DEPARTMENT INSPECTION CHECKLIST COMMERCIAL/CZC SITES This checklist should be attached to the inside cover of the CZC file at ALL times. --� Planner/Inspector Name: Project Name: Contractor/Company Name: CZC File No.: Phone No.: First Inspection Date: Second Inspection Date: Third Inspection Date: _/ / (NOTE: If a third inspection is required, a fee of $60 must be submitted to the P&ZDept. be ore the inspection is done) Landscape Plan Checklist Bei', _)i:..:i.j. S : 'P<7iBrad iP $7..4d?nir, Pt:(xi?'nnPr;t Poticiac ,e Plait Cheeldist Rev. 5,25/05 { Post -Inspection Checklist (Follow 5 steps below) 1.Obtain bid for incomplete improvements + 110% 2.0 er/contractor posts surety (cash, check or Letter of Credit) 3. Clearly print # of days the "Temp CO" is valid on card 4. Sign "Temporary" column on CO card S. Submit check or Letter of Credit to Finance Dept. with memo 1. Sign and date "Final" column on CO card 2. Notify Finance Dept. to release surety (if it was a Temporary CO) 2. Complete checklist and close file * The only instance that a CO maybe released prior to 100% completion of improvement is inclement weather, as determined by the Director. If weather is a factor, follow MCC 12-13-19-2. 3 Rev, 5%25j,05 .: I'c4"/.'.i3r'tail!°<\Y..lrls yI;-i)�.'(hit'SiJ7E7ir f°u[t Ci Pi.