Loading...
Kohl's Department Store CZC 06-037CITY OF — {1 IDAHO Wet 1903 CERTIFICATE OF ZONING COMPLIANCE* Date: March 31 2006 Project Name/Number: Kohl's Department Store — CZC-06-037 Owner: Winston Moore Site Address: Northwest corner of Ustick Road and Eagle Road Proposed Use: 95,966 square foot department store Zoning: C -G Comments: Conditions of Approval: Project is subject to all current City of Meridian ordinances and the Kohl's Conditional Use Permit. The issuance of this permit does not release the applicant from any previous requirements of the other permits issued for this site, including CUP -05-048. Landscaping: The Landscape Plan prepared by The Land Group, Inc., on March 15, 2006, labeled Sheets L1.0 and Ll. 1, is approved (stamped "Approved" on March 31, 2006 by the Meridian Planning Department) with no changes. The approved landscape plan is not to be altered without prior written approval of the Planning Department. No field changes to landscape plan permitted; prior written approval of all material changes is required. Site Plan: The Site Plan prepared by Quadrant Consulting, Inc., on March 13, 2006, labeled Sheet S-1, is approved (stamped "Approved" on March 31, 2006 by the Meridian Planning Department) with no changes. The approved site plan is not to be altered without prior written approval of the Planning Department. NOTE: Any roof -mounted mechanical equipment shall be screened from view from the public streets. Elevations: This project complies with the Design Review requirements of UDC 11-3A-19 and as required with CUP-05-048.The Elevations prepared by Perkowitz & Ruth Architects, on 3-14-06 are approved with the following change: 1) Consistent with the elevations approved with the CUP, add a concrete reveal/accent band to the rear (west) elevation. Said concrete reveal/accent band shall run the entire length of the building and be of a different color than the adjacent material. Irrigation: An underground, pressurized irrigation system must be installed to all landscape areas per the approved specifications and in accordance with UDC 11-3A-15. Protection of ExistingTrees: rees: Any existing trees on site must be protected or mitigated for in accordance with the Tree Preservation section of the City's Landscape Ordinance. Per UDC 11-3B-10, coordinate with the Parks Department Arborist (Elroy Huff, 888-3579) for approval of protection/relocationmeasures for the existing trees prior to construction. Any severely damaged tree must be replaced in compliance with UDC 11 -3B -10-C.5. Parking: The proposed parking areas shall be paved and striped in accordance with UDC 11-3B. Project engineer/architect shall certify that the number and size of handicap -accessible spaces conforms to the Americans 1D -PT CITY OF- ert�rcnw.`_ li IDAHO CERTIFICATE OF ZONING COMPLIANCE* Date: March 31 2006 Project Name/Number: Kohl's Department Store — CZC-06-037 Owner: Winston Moore Site Address: Northwest corner of Ustick Road and Eagle Road Proposed Use: 95,966 square foot department store Zoning: C -G Comments: Conditions of Approval: Project is subject to all current City of Meridian ordinances and the Kohl's Conditional Use Permit. The issuance of this permit does not release the applicant from any previous requirements of the other permits issued for this site, including CUP -05-048. Landscaping: The Landscape Plan prepared by The Land Group, Inc., on March 15, 2006, labeled Sheets L 1.0 and Ll, 1, is approved (stamped "Approved" on March 31, 2006 by the Meridian Planning Department) with no changes. The approved landscape plan is not to be altered without prior written approval of the Planning Department. No field changes to landscape plan permitted; prior written approval of all material changes is required. Site Plan: The Site Plan prepared by Quadrant Consulting, Inc., on March 13, 2006, labeled Sheet S-1, is approved (stamped "Approved" on March 31, 2006 by the Meridian Planning Department) with no changes. The approved site plan is not to be altered without prior written approval of the Planning Department. NOTE: Any roof -mounted mechanical equipment shall be screened from view from the public streets. Elevations: This project complies with the Design Review requirements of UDC 11-3A-19 and as required with CUP-05-048.The Elevations prepared by Perkowitz & Ruth Architects, on 3-14-06 are approved with the following change: 1) Consistent with the elevations approved with the CUP, add a concrete reveal/accent band to the rear (west) elevation. Said concrete reveal/accent band shall run the entire length of the building and be of a different color than the adjacent material. Irrigation: An underground, pressurized irrigation system must be installed to all landscape areas per the approved specifications and in accordance with UDC 11-3A-15. Protection of ExistingTrees: Any existing trees on site must be protected or mitigated for in accordance with the Tree Preservation section of the City's Landscape Ordinance. Per UDC 11-3B-10, coordinate with the Parks Department Arborist (Elroy Huff, 888-3579) for approval of protection/relocation measures for the existing trees prior to construction. Any severely damaged tree must be replaced in compliance with UDC 11 -3B -10-C.5. Parking The proposed parking areas shall be paved and striped in accordance with UDC 11-3B. Project engineer/architect shall certify that the number and size of handicap -accessible spaces conforms to the Americans D Planning Department WAHO ADMINISTRATIVE REVIEW APPLICATION MAR 'but pCI'i Y DIAN 0-F ZONING Type of Review Requested (check IWa apply) ❑ Accessory Use ❑ Alternative Compliance certificate of Zoning Compliance ❑ Conditional Use Permit Minor Modification ❑ Design Review ❑ Property Boundary Adjustment ❑ Short Plat ❑ Temporary Use Certificate of Zoning Compliance ❑ Time Extension (Director) ❑ Vacation ❑ Other Applicant Information Applicant name: G3 1 c4 s %K k4l.. r< C Phone: 3 4 3 -// r// i Applicant address: i9 Y0 o"C7b ly /CG Zip: 8 3 C YZ Applicant's interest in property: 1r Own ❑ Rent ❑ Optioned ❑ Other Owner name: C_� t&% z f o H W ao 141 Phone: 3 A 3 '/ S'/ Owner address: 0 Y Q t o 0' / C e Zip: Agent name (e.g., architect, engineer, developer, representative): C u c K Firm name:�"0' � �c�. ►� Co Address:�a I/ . O u 4 k< Primary contact is: ❑ Applicant ❑ Owner ❑ Agent tether LcContact name: J o � o�,f a c.., S'r' r' C E-mail: 'T. 'r e L' L @ C(I-} N <? f' Information Cr 3 GfY2 Phone: 3 Y.2—aa,9/ Zip: 93 7 0 f Phone: Fax: Location/street address: /V- W- Cn AH-eK 6F u S fi c k Assessor's parcel number(s): -S 0 5 3 Z Y Y 90 a 6 Township, range, section: St? T `Y/Y, 4I F Current land use:CA +� !�:'�y ` Total acreage:�8. 3� Current zoning district: C, G 660 E. Watertower Lane, Suite 202 • Meridian, Idaho 83642 Phone: (208) 884-5533 • Facsimile: (208) 888-6854 • Website: www.meridiancity,or-g 1 Project/subdivision name: General description of proposed project/request: K, It / r ,i C Z C Proposed zoning district(s): C " a Acres of each zone proposed: Type of use proposed (check all that apply): ❑ Residential 'Commercial ❑ Office ❑ Industrial ❑ Other Amenities provided with this development (if applicable): Who will own & maintain the pressurized irrigation system in this development? Which irrigation district does this property lie within? SCz W K S' Primary irrigation source: :r K r (2'4 tl`i 63-1 f _ Secondary: C= t 1 Square footage of landscaped area o be irrigated (if primary or secondary point of connection is City water): Residential Project Summary (if applicable) Number of residential units: Number of common and/or other lots: Number of building lots: Proposed number of dwelling units (for multi -family developments only): 1 Bedroom: Minimum square footage of structure(s) (excl. garage): Minimum property size (s.f): _ Gross density (DU/acre-total land): Percentage of open space provided: Percentage of useable open space: _ Type of open space Type of dwelling(B) 2 or more Bedrooms: ed building height: Average property size (s.£): Net density (DU/acre-excluding roads & alleys): Acreage of open space: (See Chapter 3, Article G, for qualified open space) acres (i.e., landscaping, public, common, etc): ❑ Single-family ❑ Townhomes ❑ Duplexes ❑ Multi -family Not residential Project Summary (if applicable) Number of building lots: Other lots: Gross floor area proposed:S, c% ,� G Existing (if applicable): N . Hours of operation (days and hours): a uo.r (aG �c= Building height: o? S � fa 3 O a Percentage of site/project devoted to the following: Landscaping: Building: 2 Y c�'y 7 Paving:G 3. a/ o Total number of employees: — Maximum number of employees at any one time: T - Number and ages of students/children (if applicable): Seating capacity: Total number of parking spaces provided: ��� G Number of compact spaces provided: Authorization Print applicant name: �� �t 6 Ca C F6K. GJ J ti d 1�n (-t PAC v PC 0 Applicant signature: Date: 60 E. Watertower L ne, Suite 202 • Meridian, Idaho 83642 Phone: 8) 884-5533 Facsimile: (208) 888-6854 e Website: www.me;ridiancit .or 2 W.H.9 1WlOORE C O M P A N Y Real Estate Development TELEPHONE (208) 323.1919 / FAX 323.7523 EI Dorado Business Campus 1940 S. Bonito Way, Suite 160 Meridian, Idaho 83642 P.O. Box 8204 Boise, Idaho 83707-2204 Date: March. 15, 2006 To: C. Caleb Hood Planning & Zoning Department City of Meridian 200 Watertower Lane, Ste 202 Meridian, ID From: Jonathan R. Seel Subject: Certificate of Zoning Compliance - Kohl's Department Store We are requesting a certificate of zoning compliance for a 95,966 square foot Kohl's department store located in a site owned by Winston Moore and located on the northwest corner of Ustick and Eagle Road. As background information, in 2004 this 58 acre site was approved for annexation and rezone with a development agreement under the name Blue Marlin. The annexation file number is AZ -03-025 and the DA instrument No. is 105048798. The DA required all developments be approved through the conditional use process: In October, 2005 a conditional use permit was approved for the Kohl's department store. The building will consist of a variety of materials and finishes on each of the elevations. Please refer to attached elevations for specifics. In general, the building will be a CMU wall system with a textured coating. The East Elevation (Eagle Road) will have a modulated front fagade. The finishes along this face will include multiple colors of porcelain tile, dryit system and cornice, white aluminum storefront, accent reveal lines and dominate entry features. The South Elevation will have additional Kohl's entry features, added column features and the same finishes, reveals and cornice treatments as the East Elevation. The West Elevation incorporates the same column features, finishes and reveals as noted above on the east and south sides. The North Elevation, again, repeats the same color and finish scheme as the other sides of the building. The front of the building also includes entry plaza with landscape and hard paved surfaces for the customers' use. These landscape elements are used to break up the wall's surface and provide landscape relief for the front facade. The loading dock area has a screen wall Meridian Planning & Zoning 3/15/2006 Page 2 of 2 to block the truck views from the property to the west. The west side of the store will have a dock high grade showing along the loading dock area. The signage is shown on the elevation where they will be placed. The parking area will incorporate landscaping through parking islands that will confirm to Meridian's landscape ordinance. Kohl's with use trash compactors, one for trash and one for cardboard. Information on these compactors are included with the application. These compactors will be have an 8 foot screen wall constructed of CMU. Kohl's will use a private firm to pick up the cardboard and trash. In other words, Sanitary Service Company will not be used. The loading dock will be screened with an 8 %Z foot screen wall constructed of CMU. VICINITY MAP - CENTREPOINTE SUBDIVISION �nAYw 149mIdID6 mmm mma�a� ap a�is�a NOTES: PERENNIAL GRO NDCOVER A PLANTING tlp1l troll Wm i sf11m1r•'YaquaM Q m�W rmim NOTES: ®D. D CID O S TREE SGLE 1ti10O Sr LOCATION jl 0 -------------- I-V MIN 171 A; II N lr l I I . . .. . . . . ... .................... FIRM—. .. . ....... FP IrEw ...... ..... . as _u-1-i's .. . ....... II J L ------------ . ....... . . A A i W11111111 it. Of lilt fill IR I D ti film . I fill f 1.11 R ji 1: if see T7 o w EEE; IEEE Ev, KOHL'S Meridian, Idaho �WC7 U CD Phone ITl CASH CHECR # NAME ON C CK IF DIFFERENT THAN APPLICANT �7 DESCRIPTION AMOUNT a) p u t I I C (D =r CL W D;� I I I �,CD I I I I I N C I I W I I I I I I I � k I I I I CITY OF ert�rcn 33 E. Idaho Ave. Meridian, ID 83642 Date J — 4YO Applicant Address Z. A0 6 --%" r �(p Phone QUAN. CASH CHECR # NAME ON C CK IF DIFFERENT THAN APPLICANT �7 DESCRIPTION AMOUNT t I I 71 I i I I I I I I I I I I I I I I I I I I I I I I I I i I .. Q, I I I C TAX I N TOTAL I Q o. I CITY OF ert�rcn 33 E. Idaho Ave. Meridian, ID 83642 Date J — 4YO Applicant Address Z. A0 6 --%" r �(p Phone QUAN. CASH CHECR # NAME ON C CK IF DIFFERENT THAN APPLICANT �7 DESCRIPTION AMOUNT t I I I i I I I I I I I I I I I I I I I I I I I I I I I I i I I I I I I PAYMENT DOES NOT INDICATE ACCEPTANCE OF APPLICATION TAX I 7557 Received Y TOTAL I 55748 Planning Department CERTIFICATE OF ZONING COMPLIANCE Application Checklist Project name: Ko O ` -s V o K c' File #• Cw 06-a'i� Applicant/agent: -7 o it a K j ce'' C. jr. K GJ f 'q S/ • °a. k4400 '< c,' All applications are required to contain one copy of the following unless otherwise noted: Applicant Staff Description —Complete & signed Administrative Review Application Narrative fully describing the proposed use of the property, including the following: ➢ Information on any previous approvals or requirements for the requested use i.e., applicable conditions of approvalor Development Agreement) Recorded warranty deed for the subject property Affidavit of Legal Interest signed & notarized by the property owner (If owner is a corporation, submit a co of the Articles of Incorporation or other evidence to show that the person signing is an authorized agent.) Scaled vicinity map showing the location of the subject property �Sanitary Service Company approval for trash enclosure & access drive (stamped site plan) A photometric test report for any light fixture(s) with a maximum output of 1,800 lumens or more see UDC 11-3A-11 Site Plan -4 copies (folded to 8'/2" x 11" size) The following items must be shown on the siteplan: • Date, scale, north arrow, and project name (scale not less than 1"=50') • Names, addresses, and telephone numbers of the developer and the person and/or firm preparing the plan • Parking stalls and drive aisles • Trash enclosures location • Detail Of trash enclosure (must be screened on 3 sides) • Location and specifications for underground irrigation (Pressurized irrigation be can only waived if you prove no water rights exist to subject property) • Sidewalks or pathways (proposed and existing) • Location of proposed building on lot (include dimensions to property lines) • Fencing (proposed and existing) • Calculations table including the following: Number of parking stalls required & provided (specify handicap & compact stalls) ➢ Building size (sq. ft.) ➢ Lot size (sq. ft.) ➢ Setbacks ➢ Zoning district • Reduction of the site plan 8 ''/2" x 11 ") Landscape plan - 3 copies (folded to 8 %2" x 11" size) Plan must have a scale no smager than I " = 50'(1 " = 20' is preferred) and be on a standard drawing sheet, not to exceed 36"x 48" (24"x 36" is preferred). A plan which cannot be drawn in its entirety on a single sheet must be drawn with appropriate match lines on two or more sheets. The following items must be included on the landscapeplan: • Date, scale, north arrow, and project name • Names, addresses, and telephone numbers of the developer and the person and/or firm preparing the plan 660 E. Watertower Lane, Suite 202 • Meridian, Idaho 83642 Phone: (208) 884-5533 • Facsimile: (208) 888-6854 • Website: www.meridiancity.org A CHD Acce tance: Applicant shall be responsible for meeting the requirements ofACHD as theypertain to this application. All impact fees, if any, shall be paid prior to the issuance of a building permit. If any changes must be made to the site plan to accommodate the ACHD requirements, a new site plan shall be submitted to the City of Meridian Planning & Zoning Department for approval prior to the issuance of a building permit. Your building permit will not be issued until ACHD has approved your plans and all associated fees have been paid. THIS APPLICATION SHALL NOT BE CONSIDERED COMPLETE UNTIL STAFF HAS RECEIVED ALL REQUIRED INFORMATION. • Existing natural features such as canals, creeks, drains, ponds, wetlands, flood plains, highgroundwater areas, and rock outcroppings. • Location, size, and species of all existing trees on site with trunks 4 inches or greater in diameter, measured 6 inches above the ground. Indicate whether the tree will be retained or removed. • A statement of how existing healthy trees proposed to be retained will be pr tected from damage during construction • Existing structures, planting areas, light poles, fences, berms, power poles, walls, parking and loading areas, vehicular drives, trash areas, sidewalks, pathways, stormwater detention areas, signs, street furniture, and other man-made elements. • Existing and proposed contours for all areas steeper than 20% slope. Berms shall be shown with one -foot contours. • Sight Triangles as defined in 11-3A-5 of this ordinance. • Location and labels for all proposed plants, including trees, shrubs, and groundcovers (trees must not be planted in City water or sewer easements). Scale shown for plant materials shall reflect approximate mature size • A plant list that shows the plant symbol, quantity, botanical name, common name, minimum planting size and container, tree class (I, II, or III), and comments (for s cing, staking, and installation as appropriate). • Planting and installation details as necessary to ensure conformance with all required standards. • Design drawing(s) of all fencing proposed for screening purposes • Calculations of project components to demonstrate compliance with the requirements of this ordinance, including: ➢ Number of street trees and lineal feet of street frontage ➢ Width of street buffers (exclusive of right-of-way) ➢ Width of parking lot perimeter landscape strip ➢ Buffer width between different land uses (if applicable) ➢ Number of parking stalls and percent of parking area with internal landscaping ➢ Total number of trees and tree species mix ➢ Mitigation for removal of existing trees, including number of caliper inches being removed Reduction of the landscape plan 8 ''/2" x 11" Building elevations showing construction materials Fee f this project had prior approval on a site plan, reduced fees may apply) A CHD Acce tance: Applicant shall be responsible for meeting the requirements ofACHD as theypertain to this application. All impact fees, if any, shall be paid prior to the issuance of a building permit. If any changes must be made to the site plan to accommodate the ACHD requirements, a new site plan shall be submitted to the City of Meridian Planning & Zoning Department for approval prior to the issuance of a building permit. Your building permit will not be issued until ACHD has approved your plans and all associated fees have been paid. THIS APPLICATION SHALL NOT BE CONSIDERED COMPLETE UNTIL STAFF HAS RECEIVED ALL REQUIRED INFORMATION. .,DA COUNTY RECORDER ,1. DAVID NAVARRO BOISE, 10AHO 2001 KR 29 PM 4: 43 RECORDED'�XR -Sly t IF l P.U.T.YT-Agl� 10102.8704 STEWART TITLE WARRANTY DEED For Value Received ELISABETH W. AWES, a married woman as her sole and separate property the Grantor hereby grants, bargains, sells, conveys and warrants unto WINSTON H. MOORE the Grantee whose current address is: P. 0, BOX 8204, BOISE, ID 83707 the following described premises, to -wit: AS PER LEGAL DESCRIPTION ATTACHED HERETO e Parcel Number: 50532417400 SUBJECT TO: Current General Taxes, a lien in the process of assessment, not yet due or payable. Easements, restrictions, reservations, provisions of record, and assessments, if any. TO HAVE AND TO HOLD the said premises, with their appurtenances unto the said Grantee, their heirs and assigns forever. And the said Grantor does hereby covenant to and with the said Grantee, that it is the owner in fee simple of said premises; that said premises are free from all encumbrances and that he will warrant and defend the same from all lawful claims whatsoever. Dated: March 23, 2001 i4,4"t;4 '//V aw.", ELISABETH W. AWES State of �✓�`rn``� ss. County of " Otto On this ol'L day of MARCH , 2001 , before me, the undersigned, a Notary Public, in and for said State, personally appeared ELISABETH W. AWES ALL-PURPOSE ACKNOWLEDGEMENT State of California County of San Diego On A{ ara4, 2G, 2a�1 (DATE) personally appeared e / before me, Raymond R. Shafa, Notary Public (NOTARY) ❑ personally known to me - OR - ® proved to me on the basis of satisfactory evidence to be the person(PQ whose name(,) is/a;e subscribed to the within instrument and acknowledged to me that Wshe/toy executed the same in h:Wher/t4Rfr authorized capacity(aos), and that by laiS-/her/t&-it signatures(o) on the instrument the person(, or the entity upon behalf of which the person(o) acted, executed the instrument. WITNESS my hand and official seal. NOTARY'S SIGNATURE OPTIONAL INFORMATION The information below is not required by law. However, it could prevent fraudulent attachment of this acknowl- edgement to an unauthorized document. CAPACITY CLAIMED BY SIGNER (PRINCIPAL) INDIVIDUAL ❑ CORPORATE OFFICER TmE(S) ❑ PARTNER(S) ❑ ATTORNEY-IN-FACT ❑ TRUSTEE(S) ❑ GUARDIAN/CONSERVATOR ❑ OTHER: SIGNER IS REPRESENTING: NAME OF PERSON(S) OR ENTITY(IES) DESCRIPTION OF ATTACHED DOCUMENT TITLE OR/rYPE O/ F DOCUMENT I NUMBER OF PAGES DATE OF DOCUMENT /V li . RIGHT THUMBPRINT OF SIGNER APA 51'99 VALLEY -SIERRA. 800.362-3369 OTHER m CL EOK CL 12 LEGAL DESCRIPTION Order Number: 00009418 A PORTION OF SECTION 32, TOWNSHIP 4 NORTH, RANGE I EAST, BOISE MERIDIAN, ADA COUNTY, IDAHO, MORE PARTICULARLY DESCRIBED AS FOLLOWS: COMMENCING AT THE QUARTER CORNER COMMON TO SECTION 32, T4N, R1E, BM, AND SECTION 5, T31V RIE, BM; THENCE NORTH 2,653.50 FEET TO THE CENTER OF SAID SECTION 32; THENCE SOUTH 89042100" WEST 90.90 FEET ALONG THE EAST -WEST CENTERLINE OF SAID SECTION 32 TO AN IRON PIN; THENCE SOUTH 13006100" EAST 109:00 FEET TO A POINT; THENCE SOUTH 29946100" EAST 43.30 FEET TO A POINT; THENCE SOUTH 53°13100" EAST 164.80 FEET TO A POINT; THENCE SOUTH 65027100" EAST 111.00 FEET TO A POINT; THENCE SOUTH 66009'00" EAST 283.70 FEET TO A POINT; THENCE SOUTH 78021100" EAST 160.90 FEET TO A POINT; THENCE SOUTH 70°47100" EAST 12.1.50 FEET TO A POINT; THENCE SOUTH 63004'00" EAST 177.50 FEET TO A POINT; THENCE SOUTH 48011'00" EAST 154.02 FEET TO A POINT; THENCE NORTH 89042'00" EAST 1,348.57 FEET TO A POINT; THENCE SOUTH 00001'00" EAST 225.00 FEET TO A POINT; THENCE NORTH 89042100" EAST 315.40 FEET TO A POINT ON THE CENTERLINE OF EAGLE ROAD, SAID POINT BRING THE REAL POINT OF BEGINNING; THENCE SOUTH 89042'00" WEST 315.40 FEET TO A POINT; THENCE NORTH 00001'00" WEST 225.00 FEET TO A POINT; THENCE SOUTH 89042100" WEST 1,348.57 FEST TO A POINT; THENCE SOUTH 48011100" EAST 44.58 FEET TO A POINT; THENCE SOUTH 32011'00" EAST 201.40 FEET TO A POINT; THENCE SOUTH '4-5024100v EAST 99.3o FEET TO A POINT; THENCE SOUTH 27006100" EAST 31.80 FEET TO A POINT; THENCE NORTH 89°54100" EAST 237.20 FEET TO A POINT; THENCE SOUTH 63006'00" EAST 241.00 FEET TO A POINT; THENCE SOUTH 38006100" EAST 193.50 FEET TO A POINT; THENCE SOUTH 73°24100" EAST 243.40 FEET TO A POINT; THENCE SOUTH 84°08'00 "EAST 399.60 FEET TO A POINT; THENCE SOUTH 64°37100'" EAST 240.40 FEET TO A POINT; THENCE NORTH 89042'00" EAST 25.00 FEET TO A POINT ON THE CENTERLINE OF EAGLE ROAD; THENCE IN A NORTHERLY DIRECTION ALONG SAID CENTERLINE TO THE REAL POINT OF BEGINNING. N Order No. 00008714 This form furnished by Stewart Title of Boise, Inc. ADA COUNTY RECORDER J. DAVID NAVARRO AMOUNT COD BOISE IDAHO 10/21104 04:19 PM DEPUTY Ronnie RECORDED-REQUESTOF III I'IIIIII�I'I�IIIIIIIIIIIIIII'll'll Stewart Title Company 104134508 WARRANTY DEED For Value Received JOANN C.RAWFORD and JACK CRAWFORD, wife and husband .and JACK R. JOSLIN and DENISE L. JOSLIN, husband and wife the Grantor hereby grants, bargains, sells, conveys and warrants unto WINSTON H. MOORE the Grantee whose current address is: P. O. BOX 8204 BOISE, ID 83707-2204 the following described premi;cs, to -wit: AS PER LEGAL DESCRIPTION ATTACHED HERETO TO HAVE AND TO HOLD the said premises, with their appurtenances unto the said Grantee, their heirs and assigns forever. And the said Grantor does hereby covenant to and with the said Grantee, that it is the owner in fee simple of said premises; that said premises are free from all incumbrances and that he will warrant and defend the same from all lawful claims whatsoever. Dated: October 30, 2000 06AM, CRAWFO JACK R. SL 61 Q'a. CK CRAWFO DENISE L. JOSLIN State of ID ss. County of ADA On this 30th day of_ October 2000 ,beforeme,the undersigned, a Notary Public, k! a:td for said State, personally appeared JOANN cRAWFoRD aid JACK CRAWFORD and JACK It. JOSLIN and DENISE L. JOSLIN _ known to me, and/or identitie i to :.ne on the basis of satisfactory evidence, to be the persons) whose name is/are subscribed to the within instrument acini ac'tnowledged to me that they executed the same. WITNESS M HAND AND CIFF IAL SEAL. Notary tc Residi at: NAUPA, IN Co sion Expires: December 09, .2000 y„unn,np 5dl r y S , t2, , �` '��ynnu,f�• LEGAL DESCRIPTION Order Number.• 00008724 A PARCEL OF LA'VD BEING A PORTION OF 4 NORTH, RANGE I EAST, BOISEE' SOUT7iEAST 1/4 OF SECTION 32 PARTICULARLY DESCRIBED MERIDIAN, ADA COUNTY, IDAHO TOWNSHIP CO,CING AT A BRASS G'AP FOLLOWS: ARE T'HE'1VCE ALONG TBE EAST BOK21VG T74E SOUTHEAST CORNER OF SAID SECTION 32; NORTH 00* UME'�' OF SAID SECTION 32 30 22" EAST 446.00 FEET FEET, TO A PDXXT, THENCE LEAVING SAID E 00 NORTH 89° FOBOY o 22' 00" WEST 445.40 33 24 " WEST, FORMURLY SOUTH 89 ° n PIN ON THE WEST RIGHT-OF-WAY LINE OF NORTX•38 00 WEST 32.01 FEET TO POINT OF BEGINNING; T`HE'NCE CONTINUING EAGLE ROAD 'N IRON NORTH 890 SAID POINT1RKING THE 33 24" WEST 655.21 FEET IRON PINI THENCE FOP 16RLY SOUTH 890 38' 00" WEST, TO NORTH 550 27' 55" WEST 179.96 FEET AN FEET TO AN IRON PIN; THENCE, ' FORMER ° 40' 30 LY NORTH 560 17' 00" WEST 180.0 NORTH 78 "WEST 258.02 FEST, FORMERLY NORTH 79° 57' 00n TO AN IRON PIN; THENCE WEST 261.0 NORTH 720 40 30" WEST 249.12 BEET, FO FEET, TO AN IRON PIN ON RM'�I' NORTH 734 ' I/4 OF SECTION 32; THON E WEST BOUNDARY Op �' S7 00" WEST 252. 0 ALONG SAID TBE E' ST I/2 OF SAID SOUTHEAST ° 30' 05 WEST BOUNDARY FEENORTH 000 p " EAST 653.97 FEET, FORMERLY NORTH 00- TO THE NORTHWEST CORNER OF 22 00"WEST 656.80 SECTION 32; THENCE CONTINUING THE SOUTHEAST 1/4 OF SAID SO NORTH 000 30' p5n EAST 159M7MAST 1/4 OF BOUNDARY .20 FEET TO AN IRON PIN; THENCE L NSAVING SAM WEST NORTH 28 ° 02 00" WEST 238.39FEET, FORM FEET, TO AN IRON PIN; THENCE E RLY NORTH 270 06'n 00 WEST 236.0 NORTH 890 55' 29" EAST 237.05 FEET, FEET, TO AN IRON PIN ON FORMERLY NORTH 890 54' 00" NORTH BANK THE NORTH BANK OF A CERTAIN DITCH; T•X EAST 237'2 ENCS ALONG SAID SOUTH 630 06' 38" EAST 240.41 FEET, FORMERLY SO o , FEET, TO AN IRON PIN; THENCE CONTI D 63 SOUTH 380 02' 52�' NUING 06 00" EAST' 241.0 FEET, TO XT' 193.20 FEET, FORME SOUTH 38 ' 00 A2 IRON PIN: THENCE CONTINUING RLY SO o SOUTH 7.30 NiIING 06 "EAST 193.5 2Z 54" EAST 243.49 FEET FO FEET, TO AN IRON PIN; RME�Y SOUTH 73 ° ' THENCE CONTINUING 24 00" EAST 243.4 SOUTH 820 27' 42 n ,AST. 400.03 FEET, FEET, TO AN IRON PIN; FORMERLY SOUTH 840 08' 00" SOUTH 62 0 28, 13 n THENCE CONTINUING EAST 399. 6 FEET, TO AV IRON PI SON SAIDS FEET, FORMERLY SO o , THENCE ALONG WEST RIGHT-OF-WAY LINE60F 37 00" EAST 240.4 SAID WEST RIGHT -op -WAY LINE 25.00 FEET NORTH EAGLE ROAD; SAID EAST BOUNDARY OF SECTION 32 WEST OF SOUTH 00° 30' 229 AND PARALLEL TO WEST 462.67 FEET TO A BRASS CAP; PARALLEL LINE AND CONTINUING THENCE LEAVING SAID SOUTH 020 50' 52" WEST 299.50 FEET TO THE POINT OF BEGINNING. stewar-E itle of boise ADA ADA COUNTY RECORDER J. DAVID NAVARRO AMOUNT 6.00 2 BOISE IDAHO 04121/05 04:18 PM DEPUTY NHaney III IIIIIIIIIIIIIIIIIIIIIIIIIIIiIIIIII RECORDED- -REQUEST OF Stewart Title Company 105048944 11MU s DEED For Value Received John H. Nesmith, an unmarried person the Grantor, hereby grants, bargains, sells, conveys and warrants unto RECEIVED MAY 11 2005 Winston H. Moore, the grantee, whose current address is P. 0. Box 8204 Boise, ID 83707 the following described premises, to wit: See "Exhibit A" attached hereto ; Parcel Number: 50532449300 SUBJECT TO: Current General Taxes, a lien in the process of assessments, not yet due or payable. Easements, restrictions, reservations, provisions of record, and assessments, if any. TO HAVE AND TO HOLD the said premises, with their appurtenances unto the said Grantee, their heirs and assigns forever. And the said Grantor does hereby covenant to and with the said Grantee, that it is the owner in fee simple of said premises, that said premises are free from all encumbrances and that he will warrant and defend the same from all lawful claims whatsoever, STATE OF Idaho ) ) ss. COUNTY OF Ada ) On this 20th day of April, 2005, beforee me, the undersigned, a Notary Public, in and for said ` State, personally appeared John H. Nesmith known to me, and/or identified to me on the basis of satisfactory evidence, to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged me }at he/she/they executed the same. WITNESS UV UAND�F]EK& SEAL. Not,rngiz blic: nary .G Kalvei4ge Resit: Nampa, ID My commission expires December 14, 2006 o•. .' *40 Ivo � K � 2 - Legal Description EXHIBIT "A" Order Number: 5036266 An irregular tract in the Southeast Quarter Southeast Quarter of Section 32, Township 4 North Range 1 East, Boise Meridian, Ada County, Idaho described by metes and bounds as follows: Beginning at the Southwest corner of the Southeast Quarter of the Southeast Quarter of Section 32, Township 4 North, Range 1 East, Boise Meridian; thence North 491.28 feet to an iron pin; thence North 89°45' East 133 feet to an iron pin; thence South 491.28 feet to an iron pin; thence South 89°45' West 133 feet to the Place of Beginning. Except that portion lying within Ustick Road. And Also Excepting Therefrom:: A strip of land being the South 13.00 feet of that parcel of land as described in Warranty Deed Instrument No. 99046304, Ada County records, situated in the Southeast Quarter of the Southeast Quarter of Section 32, Township 4 North, Range 1 East, Boise Meridian, Ada County, Idaho, said strip of land being more particularly described as follows: Commencing at the Southeast comer of said Section 32, thence along the South line of said Section North 89°44'39" West 1328.23 feet to the East 1/16 corner common to said Section 32 and Section 5, Township 3 North, Range 1 East, Boise Meridian; thence leaving said South line . North 00°30'02" East 25.00 feet to the Southwest corner of said parcel being the Point of Beginning; thence along the West line of said parcel North 00°30'02" East 13.00 feet; thence along a line parallel with and 38.00 feet North of said South line of Section 32 South 89°44'39" East 133.00 feet to the East line of said parcel; thence along said East line South 00°30'02" West 13.00 feet to the South line of said parcel; thence along said South line Of said parcel North 89°44'39" West 133.00 feet to the Point of Beginning. ADA CQQIUNTY RECORDER .l. DAV(p NAYARRO 19.99 MR -3 PM 4: 17 Order No. 98003980 This form furnished by Stewart Title of Idaho, Inc. WARRANTY' DEED For Value Received TULLIS FAMILY TRUST, AN IDAHO TRUST REZORDE6.9UMT OF MwART TIT FEE 4° DEPUTY 99-021196- the 9-021I96 the Grantor hereby grants, bargains, sells, conveys and warrants unto WINSTON H. MOORE the Grantee whose current address is: P.O. BOX 8204 BOISE, ID 83707 the following descrlbed premises, to -wit: AS PER LEGAL DESCRIPTION ATTACHED HERETO TO HAVE AND TO HOLD the said premises, with their appurtenances unto the said Grantee, their heirs and assigns forever. And the said Grantor does hereby covenant to and with the said Grantee, that it is the owner in fee simple of said premises; that said premises are free from all incumbrances and that he will warrant and defend the same from all lawful claims whatsoever. Dated: TULLIS FAMILY TRUST, AN IDAHO TRUST J State of IDAHO ss. County of ADA On this -3 day of ////%�C.fi� before me, the undersigned, a Notary Public, in and for said State, personally appeared DIANNE PIERCE AND ELIZABETH TULLIS known to me, and/or identified to me on the basis of satisfactory evidence, to be the Trustee's of TULLIS FAMILY TRUST, AN IDAHO TRUST the Trust that executed the within instrument and acknowledged to me that they executed the same on behalf of said Trust. ..... t11.g0�-. WITNESS MY A4DO?KFICIAL SEAL. (SEA �c fal?q�:Ot�6. iC Resid' g at: NAM•'•,� �bx • 0 },� Commission Expires: December 09, 2000 ��'�++.,.,��•�'' LEGAL DESCRIPTION Order Number: 980039_ao A TRACT OF LAND SITUATED IN A PORTION OF THE SOUTHEAST 1/4 OF THE SOUTHEAST 1/4 OF SECTION 32, TOWNSHIP 4 NORTH, RANGE 1 EAST, BOISE -MERIDIAN, ADA COUNTY, IDAHO, DESCRIBED AS FOLLOWS: COMMENCING AT A POUND STEEL PIN MONUMENTING THE SOUTHWEST CORNER OF THE SOUTHEAST 1/4 OF SAID SECTION 32, SAID PIN BEING ON THE CENTERLINE OF USTrcx ROAD, THENCE EASTERLY ALONG SAID CENTERLINE AND THE SOUTHERLY LINE OF SAID SECTION 32 SOUTH 89°44'36" EAST A DISTANCE OF 2656.46 FEET TO A FOUND BRASS CAP MONUMENTING.TEE SOUTHEAST CORNER OF SAID SECTION 32, THENCE WESTERLY ALONG SAID SECTION LINE NORTH 89°44'36" WEST A DISTANCE OF 1195.23 FEET (FORMERLY SOUTH 89045'00" WEST A DISTANCE OF 1175.50 FEET} TO A POINT, THENCE LEAVING SAID SECTION LINE NORTH 00°30'05" EAST A DISTANCE OF 25.00 FEET TO A SET STEEL PIN ON THE NORTHERLY RIGHT-OF-WAY OF SAID USTICK ROAD, SAID PIN BEING THE POINT OF BEGINNING. THENCE ALONG SAID RIGHT-OF-WAY SOUTH 89°44136" EAST A DISTANCE OF 895.10 FEET TO A FOUND HIGHWAY MONUMENT; THENCE NORTH 85°49100" EAST A DISTANCE OF 249.65 FEET TO A FOUND HIGHWAY MONUMENT; THENCE NORTH 43028'48" EAST A DISTANCE OF 14.88 FEET TO A FOUND HIGHWAY MONUMENT ON THE WESTERLY RIGHT-OF-WAY OF EAGLE ROAD; THENCE ALONG SAID WESTERLY RIGHT-OF-WAY PARALLEL TO AND 70 FEET WEST OF THE CENTERLINE OF SAID EAGLE ROAD NORTH 01050'52" EAST A DISTANCE OF 390.49 FEET TO A SET STEEL PIN; THENCE LEAVING SAID.WESTERLY RIGHT-OF-WAY NORTH 89030118" WEST •A DISTANCE OF 655.21 FEET (FORMERLY SOUTH 89038'00" WEST A DISTANCE OF 687.70 FEET) TO A FOUND STEEL PIN; THENCE NORTH 55027'55" WEST A DISTANCE OF 179.96 FEET (FORMERLY 180.00 FEET) TO A FOUND STEEL PIN; THENCE NORTH 78040'30" WEST A DISTANCE OF 258.02 FEET (FORMERLY NORTH 79057'00'! WEST A DISTANCE OF 261.00 FEET) TO A SET STEEL PIN;. THENCE NORTH 72040130" WEST A DISTANCE OF 249.12 FEET (FORMERLY NORTH 73°57'00" WEST A DISTANCE OF 252.00 FEET) TO A SET STEEL PIN ON THE WES=TERLY LINE OF SAID SOUTHEAST 1/4 OF THE SOUTHEAST 1/4 OF SECTION 32; THENCE SOUTHERLY ALONG SAID WESTERLY LINE SOUTH 00°30105" WEST (FORMERLY SOUTH 00022'00" WEST) A DISTANCE OF 180.97 FEET TO A SET STEEL PIN; THENCE LEAVING SAID WESTERLY LINE SOUTH 89044'36" EAST (FORMERLY NORTH 89045'00" EAST) A DISTANCE OF 133.00 FEET TO A SET STEEL PIN; - Continued on next page Continuation of Schedule A - Legal Description Order Number: 98002980 THENCE SOUTH 00'30'05" WEST (FORMERLY SOUTH 00°00'00" WEST) A DISTANCE OF 466.28 FEET TO THE POINT OF BEGINNING. AFFIDAVIT OF LEGAL INTEREST STATE OF IDAHO COUNTY OF ADA e (name) (address) VAerKrcttau (city) (state) being first duly sworn upon, oath, depose and say: That I am the record owner of the property described on the attached, and I grant my permission to: J Fs do a� (.► u �. S C` c• L f %/ Ya 4,t µ r �Q Q (name) (address) to submit the accompanying application(s) pertaining to that property. I agree to indemnify, defend and hold the City of Meridian and its employees harmless from any claim or liability resulting from any dispute as to the statements contained herein or as to the ownership of the property which is the subject of the application. I hereby grant permission to City of Meridian staff to enter the subject property for the purpose of site inspections related to processing said application(s). Dated this _day of 44t m. K Q 4 , 20 G C IO l � �_, �I_ ,:1 SUBSCRIBED AND SWORN to before me the day and year first above written. ````�����1E1�•G18S0����' ✓ Public Idaho) NOTARY ' Residing at: :.PUBLIC My Commission Expires: d - 13 2b 12 Page 1 of 5 Jonathan Seel From: Dan McCrea [dmccrea@synergyengineers.com] Sent: Wednesday, March 08, 2006 5:31 PM To: Joe Janusz Cc: Jonathan Seel Subject: RE: Meridian Kohl's - Site Lighting Joe: Here's an alternate photometric layout based on our conversation. It's a little low at the SE corner of your building. You may be able to cover that with building lighting, depending on what your design ends up being. Take a look at it and let me know what you think. Thanks, Dan Dan McCrea, PE Synergy Engineers, PC 410 S. Orchard St., Suite 132 Boise, ID 83709 208-336-9617 208-336-9629 (Fax) 208-794-4941 (Cell) -----Original Message ----- From: Dan McCrea Sent: Tuesday, March 07, 2006 8:52 AM To: 'Joe Janusz; 'Yunus Kathrada' Cc: 'Jonathan Seel'; 'Nathalie Escobar' Subject: Meridian Kohl's - Site Lighting Joe/Yunus: Kohl's has now given me permission rights to post files to the Buzzsaw site and I uploaded the site photometric PDF's to the "submittal 03-03- 06" folder. I have the following comments: G The poles and fixtures will be dark bronze. f The city has a maximum mounting height limitation of 35'. G Would Kohl's prefer to illuminate the south drive isle with building -mounted wall -packs in lieu of the poles I show? G There will be three night lights along the drive in front of the store per Kohl's requirements. The design requirements state that the fixture that is oriented away from the building should be designated the night light. I show three 1000W, metal halide fixtures on each pole along the front drive in order to hit the desired light levels along the walkway in front of the store. The Kohl's guidelines indicated that the third should be oriented towards the 3/9/2006 Page 2 of 5 parking area (towards the east in this case) as opposed to being towards the building. This will create a shadow on the front fagade of the building caused by the pole being between that fixture and the building. I recommend orienting the third fixture towards the building and using the south or north fixture for night lighting. rm The design requirements state that the approved distributions are area square or symmetrical (Type V) and forward throw (type IV). This is what In order to minimize light trespass off of the property and obtain the most efficient spacing of poles I feel that type 3 should also be used. 6 I show three 1000W fixtures on two poles in the middle of the lot to meet the minimum lighting requirement of 2 foot- candles. Two fixtures per pole there yield a minimum of about 1.5 foot-candles minimum, but most of the area is still above 2 foot-candles. I would recommend changing to two per pole to save energy. Unless directed otherwise, I will leave them with three fixtures each. G I will develop a control scenario with Jonathan at WH Moore for the entries into the site and then propose it to Kohl's for approval. I look forward to hearing your comments. Regards, Dan Dan McCrea, PE Synergy Engineers, PC 410 S. Orchard St., Suite 132 Boise, ID 83709 208-336-9617 208-336-9629 (Fax) 208-794-4941 (Cell) -----Original Message ----- From: Kathy.Iwinski@kohls.com[mailto:Kathy.Iwinski@kohls.com] Sent: Tuesday, March 07, 2006 7:28 AM To: Dan McCrea Subject: RE: Welcome to Autodesk Buzzsaw! Dan, It was a permission thing and it is fixed. Sorry for the delay, but I am not always told if view privileges are enough. Kathy Iwinski Site Development Coordinator Kohl's Department Stores 262-703-2628 McCrea" 3/9/2006 "Dan ,t I '` a�•''1. 'Sw,� °*rnz ,;; x ..� � i' ,ti - r �. � - - r st' t i t 1 - .y... �..,•.:�i::aiir �fts�� r°�'fs iwu et*��•�' .5.}rry J r a�":fl��t � �� � �.Y .t- :. � i �1 '4. a` it ��ryt }t `j•,r. � x�r � 'rt 15 ��vY� �^'f: a..',4.,.z'+� �L.„�e § �.�.7"•..���.�,ry :i l�q ir�q.�rsa yet �J`�t t .:� ` � � J T���Y,e �'� �7 � �4, �` �sFf� �'"tYti���y �Y'�utL3'``'Gs. i +t Compactor Z Equipment Requirements + �:�: 4.24 COMPACTOR EQUIPMENT REQUIREMENTS �a *4, Hyl 'A Two compactors required — one compactor for trash and separate compactor for cardboard. Cd` / 7V,',/ Compactors and containers supplied by Kohl's. COMPACTOR CLEARANCES Minimum clearance between containers.............................................................20" Minimum clearance between container and screen wall......................................24" Preferred clearance between container and building wall .................................... 36" Minimum clear distance from end of container for roll -off truck .......................... 65'-0" Minimum corral / gate opening for roll -off truck..................................................12'-0" Notes: • Fire/Siamese connection location cannot be blocked by compactor or container. • Drain may not be located directly under compactor legs. • Gates should be mounted outside the mouth of any enclosed area,' not inside the screen wall. Mounting gates inside the enclosed area cuts the opening by 1'-0" to 2'-0." • Place the cardboard compactor closest to the dock/receiving area, except to protect Building. • The on-site electrician is responsible for fused disconnect, hook-up of compactor power lead to that disconnect, "bumping" motor to ensure phasing is correct, any re -wiring of factory -supplied leads which need to be converted to meet local code. COMPACTOR CLEARANCE EXAMPLE: TWO COMPACTORS IN DOCK WELL • Side-by-side configuration • Rear feed chutes. Minimum distance from concrete pad to bottom of chute door opening ........... 60" MIN. PREFER 72" Minimum height of chute door opening from finish floor (100'-0") ........................42" Minimum distance between chute door openings and adjacent building wall ...... 68" Minimum clearance on each side of the compactor door openings .....................48" Minimum width of compactor pad......................................................................22'-Ott Site Design Criteria — Compactor Equipment Requirements — April 2005 4.24-1 Compactor Equipment Requirements lYiT \i� �} 1 J Y GR- ..., r_.1. �"� tti..: r� ial f X14 i Y�tY J !tia,ry� COMPACTOR CLEARANCE EXAMPLE: TWO COMPACTORS IN SCREENED AREA Back-to-back configuration • Side feed chutes Minimum distance between compactor doors18'-0" ................................................... Minimum extent of concrete pad beyond compactor door..................................8'-0" Minimum width of compactor pad......................................................................12'-0° Notes: • All door strikes to be on the container side of door openings. • Concrete pad for compactor and container must be on the same plane. If the pad is inclined, the slope must continue under the entire compactor/container assembly, or must begin and end beyond the compactor/container assembly. • No bollards shall be placed.within the screened area. • No disconnects shall be placed on the container side of the chute opening. • If there is an obstacle outside the screened area, the compactor shall be angled to allow the roll -off truck to service the container and miss the obstacle. In this case, the screen wall should be shortened such that is covers the equipment plus 24" 4.24-2 Site Design Criteria - Compactor Equipment Requirements - April 2005 TYPICAL COMPACTOR r— +6 ---1 1jJi � Ly •.7 :t +I�w P � rn I--- TYPICAL COMPACTOR r— +6 ---1 ELECFRICAI P0111 H��/4 I--- 51004 36 CAI10H POWER UK &A AN k I.h walk MM" !Y' Compactor Equipment, Requirements 57'X 60' OMBER OPBK - 51, X 58' am OPQPIIC 81 I/2 — 67 RAI Fla — SCWR DME— L6 57T11 1 60 61 76 3/8 TYPICAL COMPACTOR CONTAINER Yell 1�• I 614U6GtVE 5NE5 CRtWP1C N1R1 POWER LR1R. I m PR Model PR2484 tapaclry at Cu Yd: 42 Apptox. SLtip WeIULd (U)s.►: 8790 flgUM More 1211Hllae -L Fir ir-4 I- I 1 For overall Length add: 13-14" For overall Helyld add:1]-1R" Unless sided otherwise In wrbV. eerdaher sixes as hdleeted on sales literature, hvolces, price lists, qudallons, and dehwy Rets are nomhal sixes. Actual vokma may very from nomhal sizes. Site Design Criteria — Compactor Equipment Requirements — April 2005 4.24-3 �..i�{L .��. '-.�. _. usmr�' �. ��at3�4•.G *_�.F:.:: �,u",.�te:'�.�:°� i ���}.�_i:w..c:c... ,Li..a:...�1, Compactor Equipment Requirements PROTOTYPICAL BL- COMPACTOR LAYOUT 0 (DOCK) SWITCHBACK STAIR 0-0' FOR ROLLOFF TRUCK CARD--.,- : I i 9B-0' 7'-0- TYP. I TYP. TYP. PLAN VIEW c; 981-0" 65'-0' y"i I GARBAGE (TYP.) N FOR ROLLOFF TRUCK • _ ___ -------- CONTAINER COMPACTOR (SIDE FEED) BY TENANT 8' CONC. SLAB- SEE STRUCT. DISCONNECT SCREEN WALL (IF APPLICABLE) 5 EXTERIOR ELEVATION TRASH COMPACTOR DETAIL COMPACTORS -SL 03/30/05 1 SCALE: N.T.S. 4.24-4 Site Design Criteria — Compactor Equipment Requirements — April 2005 FIN. L90R ELEV ViL2 �G1 1, Tf Y ,{� sr svxs + 3, Compactor Equipment Requirements PROTOTYPICAL SIDE- COMPACTOR LAYOUT MAIN STOCK ROOM 136 tem 4'-4"5'-6' 4'-4' i 5' d� VIN. 06''10DISCURNECT (e' MIN. FROM T.-a4J• i t i i i COMPACTOR) OLd0-.-N'ALq I i i j 11 o ly I O O ii li ii _il I (DOCK) i COMPACTOR (SIDE FEED) DY 7ENA4T CONTAINER f' SCREEN ViAl.l (F APPLICAHLE) CONC. 51A3 -SEE STRUCT. i 3ti� AIIN.I � i i -,o TO AOJ. O BLOC. I I i 1 I I I I -_ 20. 4 IIN. I ---� 22'-0' MIN. CONC. PAD I 4 O EXTERIOR ELEVATION TRASH COMPACTOR DETAIL COMPACTOR-SxL 1 03/31/03 1 SCALE: N.T.S. PLAN VIEW Site Design Criteria — Compactor Equipment Requirements — April 2005 4.24- { Y (io>wrw+�ec��o o✓ May 1, 2006 TO: WH Moore Jonathan Seel 1940 Bonito Suite 160 Meridian, ID 83642 SUBJECT: MCZC-06-037 Kohl's Department Store NWC Ustick & Eagle Right -of -Way & Development Department Planning Review Division On November 9, 2005, the Ada County Highway District acted on MCUP05-0481Kohl's Store. The conditions and requirements also apply to MCZC-06-037. • You will need to submit final plans to the ACHD Development Review Department prior to receiving final approval. • A traffic impact fee maybe assessed by ACHD and will be due prior to the issuance of a building permit. Contact ACHD Planning & Development Services at 387-6170 for information regarding impact fees. If you have any questions, please feel free to contact the Planning Department at (208) 387-6170. Sincerely, Karen Anderson Right -of -Way Specialist ROWDS Department cc: Project File, Construction Services Meridian City Quadrant Consultants 1904 W Overlandd Boise, ID 83705 Ada County Highway District • 3775 Adams Street • Garden City, ID • 83714 • PH 208-387-6100 • FX 345-7650 • w�v.achd.adadd. m x m O 7J m r m D ytim ��� QQQQQQQQQQQQQQQQQ 08 Qb k A oQ QolQQIi:QQt Q r gg r g ggg g m pp _ p p O 5 Q co y �� sUfl �27s Z ci 5j � e a g e e § 9 sFR £F.`.4 sig 8C' 6 `P3€`s55s .v€6 K". 'SRFq Nt('.. tg . `Fq. N qe �s4 ySyS K Y -.. nu g� R4�s m 11E S�st f e ex r � i Emn r o { hj i l 1�- 1,' :..:.....:....�.ti..0«S?L.�+'. I TYPICAL COMPACTOR I -0--I Emn H(CIRGt Pilhl � 313/4 �J SIMM 36 U1QI PXR W Compactor Equipment Requirements .9 1 16 IIt II7 I/t VAMC Y1RfN.F DERN. 1--,V TYPICAL COMPACTOR CONTAINER PR Model PR2484 01MC 11CILYIU 42 Approx. SHIP Weight 0.Ls.1: 8790 � f � I 9t9uest Mete UfonpgLpn Fzvra 4 1-11 ir-I F For oveuil LmrW � adrk 11-1f1" For overall HeIpIR adrk 1142" l.Wess skied dhervAse h miky, caAakwt rhes ax hdcdad on seks Herdve, hvokes, prke Isis, µMdkns, eM deWay ikkds ere norcihel sixes. Adud vMma meY very Iran nanvnl sties. Site Design.Criteria — Compactor Equipment Requirements — April 2005 4.24-3 Compactor Equipment Requirements ri 1� i�� VT sn Ua PROTOTYPICAL BL- COMPACTOR LAYOUT 6 5 pocx) swlTcxww cN sR I CAN I I 98 _ ------------------ 6$' p' CDBOARD ROp1gUCg'� T-0 WeAoE (TYP.)FOR .oI it n FOR ROLLOFF iRUC.K 26-1 1/4 '-10 T-0" TYP. TYP, ttP. CONTAINER COMPACTOR (SIDE FEED) BY TENANT 6' CONC. SUB - SEE STRUCT. PLAN VIEW DISCONNECT SCREEN Y/ALL QF APPLIGRLE) QII IB 0 MI . ______________ ou evii n - EXTERIOR ELEVATION TRASH COMPACTOR DETAIL COMPACipftS_BL OJ/JO/OS SCALE: N.T.S. 4.24-4 Site Design Criteria — Compactor Equipment Requirements —April 2005 fY r 1 W l l �S m i,7 — `.i v � a I zp 1, x Compactor Equipment Requirements PROTOTYPICAL SIDE- COMPACTOR LAYOUT MAIN STOCK ROOM 136 d' -d' S' -B"•4' -b" F r 5 EtflN_� 06CClIAECI (N MIt6 FHQM COMPACIOR) T(J-ANj11J. idddddd -t i t � i t it it ii ii O O r� Ir (DOCK) i ! COMPACTOR (.SIDE FEED) By TEWff i i I LONiNNER � ,� n � SCkEFN 'Ahu, ('! MFLh'NI',!) I�� I i \_ CWIC. SA - SEE STRUCT. _ F F �36" 14 N.' yy O i 03. 1 i I I I 6119. CONC. DID o � i _ EXTERIOR ELEVATION PLAN VIEW TRASH COMPACTOR DETAIL COMPACIOR_SxL 05/31/05 6CnLE; N.T.S. Site Design_Criterio — Compactor Equipment Requirements —April 2005 4.24-5 PAY TO THE ORDER OF N N� ¢ M W Io o— Y U J ¢ F F- N WW O 0 LL LL � O W U ❑ it ..._.F'PP p W a O J ¢ Z -ow1J1 W Z U O M Y w ¢ a a L W � U p > m V V Z Z m >. Z V U p O LCA N Z U > a a a` o a PLANNING & ZONING DEPARTMENT INSPECTION CHECKLIST l'�%� �i COMMERC]AL/CZC SITES \\� This checklist should be attached to the inside cover of the CZC file at ALL times. l7� Planner/7nspector///�Name: Project Name: V--0 0-i S CZC File No.: ( Z( ) CS.I Contractor/Company Name: �b }J S e C1 - 3 N7m/ Phone No.: First Inspection Date: / Y> / o Second Inspection Date: Third Inspection Date: / / (NOTE: If a third inspection is required, a fee of $60 must be submitted to the P&ZDept. before the inspection is done) Landscape Plan Checklist I Item I site Notes I n u th 1 Ret. R25.,`05 iP<''Braef:P&Z.4dmer, ilJefrar inert F a?Kies B;�Sfteeyty�hffe€ffers��tei�l�)�n�fer�LN�e$��a�rdn�,e, ��.,, .� `,��Y t sae, ��l��j,t4��;��r���.�.;s�•k?�,at 1. Width of buffer (exclude detached s/w widths) If 2. # of trees 3. Caliper/size of trees (measure 6-8 inches above t ground) 4. Species mix per plan 5. Groundcover (ifseeded; verify germination) 6. Right-of-way landscaping v 7. Verify no encroachments (e.g: fencing,parking) 8.13e ming (max. 2:1 slope; r� ' 3:1 i lawn cPiE � 1. Verify min. 5' b/w curbs 2. Verify min. 50 sq. ft. 3. Plantings per plan v - b Existing treesl�itigatlori 1. Verify existing tree(s) retained ✓ 2. Verify mitigation tree(s) planted Ret. R25.,`05 iP<''Braef:P&Z.4dmer, ilJefrar inert F a?Kies E. Sight triangle(s) Item 1. Verify size/location O.K. 2. Verify height of shrubs F.d ze irrigation (verify installed) G. $toxmwater area(s) 1. Less than 3:1 slopes 2. Dry creek formation (if applicable) 1. Max. 5 ft- dimension for J� rocksu I n1p N 4. Max. 2 ft. dimension for sand/grease grates L 177Sife Plan Checklist 2 Rev. 5.,;25,,,05 Item Site Notes O.K. I Standard stall 2. Compact stall 3. Handicap stall 4. Handicap signs/striping 5. Aisle width v- 6. Wheel stops (if required) Anclosu! A., 1. Min. 3 -sided screening 2. Constructed per plan s - �� -�' Wk� * a' �"'56 -M _' -' I 'Al I , I ! "' � I I. Verify location 2. Verify minimum width E. Curbing 1. Installed per plan ✓ F. Special conditions/Redlines*. 1. Verify any special 'c'a' conditions from CZC or =are redline notes on plan complete 2 Rev. 5.,;25,,,05 S Post -Inspection Checklist * The only instance that a CO maybe released prior to 100% completion of improvement is inclement weather, as determined by the Director. If weather is a factor, follow MCC 12-13-19-2. Rev. Si15it3j a:'•Y<4li31'2.':7�t�%:?r.i:,iY;'.:�CFki%'LitlF7li �J:iCf.'.'i