Loading...
Construction_Drawings_Sheet 3_Notes Revised This Document, and the Concepts, Ideas and Design Incorporated herein are an instrument of professional services and are the Property of Mason and Associates, Inc., therefore they are not to be used in whole or part for any other project without the express Written Authorization of Mason and Associates, Inc.© z 0 a v - w ° GENERAL CONSTRUCTION SEWER DRAINAGE ° 1. ALL CONSTRUCTION WORK SHALL BE DONE IN ACCORDANCE WITH THE CURRENT VERSION OF THE IDAHO 1. CONSTRUCTION OF THE SEWER SYSTEM SHALL CONFORM TO THE STANDARDS IN THE WASTEWATER RULES °p STANDARDS FOR PUBLIC WORKS CONSTRUCTION (ISPWC), THE CITY OF MERIDIAN SUPPLEMENTAL IDAPA 58.01.16 AS WELL AS THE STANDARD AND SPECIFICATIONS REFERRED TO IN GENERAL FOR COMMERCIAL SUBDIVISIONS OR COMMERCIAL PROJECTS WITH PUBLIC MAINS THAT HAVE ON-SITE DRAINAGE. SPECIFICATIONS TO THE ISPWC (AND ANY ADDENDUMS), MERIDIAN DESIGN STANDARDS, THE CONSTRUCTION N S NOTE NO. 1. Z REQUIREMENTS OF THE ADA COUNTY HIGHWAY DISTRICT (ACHD), AND/OR THE REQUIREMENTS OF THE 1. FOR ANY DRAINAGE FACILITIES WITHIN A PUBLIC RIGHT OF WAY, ACHD OR ITD SHALL BE RESPONSIBLE FOR IDAHO TRANSPORTATION DEPARTMENT (ITD). THE MORE STRINGENT OF ANY OF THESE STANDARDS SHALL N OF 0 WATER MAIN AND NON-POTABLE WATER MAINS SANITARY INSPECTION. FOR ANY PRIVATE DRAINAGE FACILITIES THE PROJECT ENGINEER OR ARCHITECT SHALL BE SNOISIA98 ( ) 2. THE HORIZONTAL SEPARATION POTABLE TE S E ( d- BE THE CONTROLLING STANDARDS OR SPECIFICATIONS. SEWER, STORM DRAIN, AND IRRIGATION) SHALL BE A MINIMUM OF TEN (10) FEET. WHERE IT IS RESPONSIBLE FOR INSPECTION AND CERTIFICATION OF DRAINAGE FACILITIES; HOWEVER ANY ROOF DRAINAGEAND PIPING TO THE DRAINAGE FACILITIES WILL BE INSPECTED BY THE MERIDIAN PLUMBING OFFICIAL UNDER `� NECESSARY FOR A POTABLE WATER MAIN AND NON-POTABLE WATER MAIN TO CROSS WITH LESS THAN THE APPROPRIATE PERMIT. N N N 2. THE CONTRACTOR SHALL HAVE A COPY OF THE LATEST CITY OF MERIDIAN STANDARD SPECIFICATIONS EIGHTEEN (18) INCHES OF VERTICAL SEPARATION, THE CROSSING SHALL BE CONSTRUCTED IN AND DRAWINGS ON SITE OR READILY ACCESSIBLE AT ALL TIMES DURING CONSTRUCTION (AVAILABLE ON ACCORDANCE WITH SECTION 542.07 OF THE IDAHO RULES FOR PUBLIC DRINKING WATER SYSTEMS (IDAPA CL THE CITY WEBSITE). FAILURE TO HAVE ACCESS TO A CURRENT COPY OF THE STANDARD SPECIFICATIONS 58.01.08) AND SECTION 430.02 OF THE WASTEWATER RULES (IDAPA 58.01.16). c`n Q ON SITE COULD BE GROUNDS FOR A STOP WORK ORDER UNTIL THE SITUATION IS RESOLVED. 3. THE HORIZONTAL SEPARATION OF NON-POTABLE SERVICES AND POTABLE WATER SERVICES OR POTABLE ROADWAY m 3. THE CONTRACTOR SHALL HAVE PLANS STAMPED APPROVED FOR CONSTRUCTION BY 'CITY OF MERIDIAN o >= WATER MAINS SHALL BE A MINIMUM OF SIX (6) FEET. WHERE IT IS NECESSARY FOR A POTABLE WATER W ca W m ON SITE AT ALL TIMES, Z z MAIN AND NON-POTABLE WATER MAIN TO CROSS WITH LESS THAN EIGHTEEN (18) INCHES OF VERTICAL 1. ALL CONTRACTORS WORKING WITHIN THE PUBLIC ROAD RIGHT-OF-WAY ARE REQUIRED TO SECURE A U p SEPARATION, THE CROSSING SHALL BE CONSTRUCTED IN ACCORDANCE WITH SECTION 542.07 OF THE RIGHT-OF-WAY CONSTRUCTION PERMIT FROM ACHD OR ITD AT LEAST TWENTY-FOUR (24) HOURS PRIOR W a 4. ALL CONTRACTORS, SUBCONTRACTORS, AND UTILITY CONTRACTORS SHALL ATTEND A PRE-CONSTRUCTION IDAHO RULES FOR PUBLIC DRINKING WATER SYSTEMS (IDAPA 58.01.08) AND SECTION 430.02 OF THE TO CONSTRUCTION. p p U Q CONFERENCE PRIOR TO START OF WORK. 5. CONTRACTORS SHALL NOTIFY THE APPROPRIATE AGENCY WHEN MATERIALS ARE ON SITE OR INSPECTION WASTEWATER RULES (IDAPA 58.01.16). 2. ACHD OR ITD WILL INSPECT ALL WORK WITHIN THE PUBLIC RIGHTS-OF-WAY TO INCLUDE UTILITY - . . . OF THE WORK IS REQUIRED. NO WORK MAY BEGIN ON ANY PROJECT WITHOUT TWENTY FOUR (24) HOUR 4. PLACE SEWER SERVICE LINES IN A SIX (6) INCH DIAMETER WATER CLASS PIPE SLEEVE WHEREVER THE TRENCHES ABOVE THE PIPE ZONE. = o PRIOR NOTICE. SERVICE LINE CROSSES A STORM WATER TREATMENT FACILITY (I.E., SEEPAGE BEDS, DRAINAGE SWALES). r C 3. THE ENGINEER OF RECORD CERTIFIES THAT THE PLANS ARE PREPARED IN SUBSTANTIAL CONFORMANCE m n. WITH THE ACHD POLICY AND STANDARDS IN EFFECT AT THE TIME OF PREPARATION. THE ENGINEER w z 6. CONTRACTOR SHALL NOTIFY THE PUBLIC WORKS INSPECTOR 48 HOURS PRIOR TO THE REQUIRED TESTING. v � o ACKNOWLEDGES THAT ACHD ASSUMES NO LIABILITY FOR ERRORS OF DEFICIENCIES IN THE DESIGN. ALL C o THE CONTRACTOR MAY NOT OPEN OR CLOSE WATER VALVES. CLASS "A"MUNICIPAL WASTEWATER RECLAMATION AND REUSE VARIANCES FROM ACHD POLICY SHALL BE APPROVED IN WRITING. THE FOLLOWING VARIANCES LISTED BY oca DATE AND SHORT DESCRIPTION, WERE APPROVED FOR THE PROJECT. o 7. ALL MATERIAL FURNISHED ON, OR FOR THE PROJECT MUST MEET THE MINIMUM REQUIREMENTS OF THE ,w APPROVING AGENCIES. AT THE REQUEST OF THE APPROVING AGENCY OR THE DESIGN ENGINEER, FOR COMMERCIAL SUBDIVISIONS OR COMMERCIAL PROJECTS THAT HAVE PUBLIC REUSE MAIN OR SERVICES a CONTRACTORS SHALL FURNISH PROOF THAT ALL MATERIALS INSTALLED ON THIS PROJECT MEET THE SPECIFICATION REQUIREMENTS SET FORTH IN GENERAL CONSTRUCTION NOTE NO. 1. 1. CONSTRUCTION OF THE CLASS A EFFLUENT DISTRIBUTION SYSTEM SHALL CONFORM TO THE STANDARDS IN THE IDAHO RECYCLED WATER RULES (IDAPA 58.01.17), WASTEWATER RULES (IDAPA 58.01.16), RECOMMENDED SUPPLEMENTARY NOTES V) 8. WORK SUBJECT TO APPROVAL BY ANY GOVERNMENTAL AGENCY MUST BE APPROVED PRIOR TO (A) STANDARDS FOR WASTEWATER FACILITIES - GREAT LAKES - UPPER MISSISSIPPI RIVER BOARD OF SANITARY I q) BACKFILLING TRENCHES FOR PIPE, (B) PLACING OF AGGREGATE BASE; (C) PLACING OF CONCRETE, (D) ENGINEERS (10 STATES STANDARDS), AWWA MANUAL M24 - CHAPTER 24 AS WELL AS THE STANDARDS AND Ub PLACING OF ASPHALT PAVING. SPECIFICATIONS REFERRED TO IN GENERAL CONSTRUCTION NOTE N0. 1. 1. CONTRACTOR(S) SHALL RETAIN AND PROTECT ALL EXISTING FEATURES BOTH ABOVE AND BELOW GROUND, tV UNLESS OTHERWISE NOTED ON THE PLANS OR AS DIRECTED BY THE ENGINEER. u 9. INSPECTION APPROVAL AND FINAL ACCEPTANCE OF A WATER AND SEW CONSTRUCTION SHALL BE ALL ER 2. THE HORIZONTAL SEPARATION. OF CLASS A EFFLUENT DISTRIBUTION MAINS AND POTABLE WATER MAINS SHALL O BY THE PUBLIC WORKS DEPARTMENT, AND THEIR DECISION SHALL BE FINAL. SUCH INSPECTIONS SHALL Z MASON & ASSOCIATES, INC. WILL PROVIDE CONSTRUCTION STAKES AS REQUESTED BY OWNER. BE A MINIMUM OF TEN (10) FEET IN ACCORDANCE WITH IDAPA 58.01.08, "IDAHO RULES .FOR PUBLIC DRINKING NOT RELIEVE THE CONTRACTOR FROM THE RESPONSIBILITY OF PERFORMING THE WORK IN AN WATER SYSTEMS," SUBSECTION 542.07. WHERE IT IS NECESSARY FOR A CLASS A EFFLUENT DISTRIBUTION MAIN ACCEPTABLE MANNER IN ACCORDANCE . WITH THE DEQ/QLPE APPROVED .CONSTRUCTION PLANS. 3. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR ACQUIRING ANY NECESSARY NPDES PERMITS, FILING AND POTABLE WATER MAIN TO CROSS, A MINIMUM OF EIGHTEEN (18) INCHES OF VERTICAL SEPARATION SHALL ANY NOI'S, AND PREPARING A POLLUTION PREVENTION PLAN (PPP) IN ACCORDANCE WITH THE BE MAINTAINED-AND THE CLASS A EFFLUENT DISTRIBUTION MAIN SHALL BE ENCASED IN A CONTINUOUS PIPE 10. ANY DEVIATION FROM THE APPROVED PLANS AND SPECIFICATIONS MUST HAVE THE APPLICABLE AGENCY ENVIRONMENTAL PROTECTION AGENCY. CONTACT THE EPA AT (208) 334-9489 FOR THE REQUIRED SLEEVE TO A DISTANCE ON EACH .SIDE OF THE CROSSING EQUAL TO TEN (10) FEET. CLASS A EFFLUENT INFORMATION. SAID PERMIT SHALL APPROVAL IN WRITING PRIOR TO CONSTRUCTION. ALL BE PRESENTED TO THE OWNER/DEVELOPER AT LEAST 48 HOURS DISTRIBUTION MAINS INSTALLED PARALLEL TO NON-POTABLE WATER MAINS (SANITARY SEWER, STORM DRAIN PRIOR TO THE BEGINNING OF THE CONSTRUCTION. 11. PRIOR TO BEGINNING INSTALLATION OF STREET LIGHTS, THE ELECTRICAL CONTRACTOR SHALL OBTAIN AN AND IRRIGATION) SHALL BE INSTALLED AT LEAST FIVE (5) FEET HORIZONTALLY FROM THE NON-POTABLE MAIN ELECTRICAL PERMIT FROM THE BUILDING DIVISION OF THE MERIDIAN PUBLIC WORKS DEPARTMENT. ANY IF THE NON-POTABLE MAIN IF THE NON-POTABLE MAIN IS LOCATED ABOVE THE CLASS A EFFLUENT MAIN AND 4. CERTAIN CONTROL POINTS WILL BE SET BY THE ENGINEER, OR ITS REPRESENTATIVE, WHICH ARE DEVIATION IN STREET LIGHT LOCATIONS FROM THE APPROVED PLANS MUST BE APPROVED IN WRITING THREE (3) FEET HORIZONTALLY FROM THE NON-POTABLE MAIN IF THE NON-POTABLE MAIN IS LOCATED BELOW CRITICAL TO THE CONSTRUCTION STAKING OF THE PROJECT. THESE POINTS WILL BE DESIGNATED AT THE FROM THE CITY ENGINEER. THE CLASS A EFFLUENT MAIN. TIME THEY ARE SET AND THE CONTRACTOR SO NOTIFIED. DESTRUCTION OF THESE POINTS BY THE C CONTRACTOR OR HIS SUBCONTRACTORS SHALL BE GROUNDS FOR CHARGING THE CONTRACTOR FOR THE V 3. THE HORIZONTAL SEPARATION OF CLASS A EFFLUENT DISTRIBUTION SERVICES AND POTABLE WATER SERVICES COST OF RE-ESTABLISHING SAID POINTS. V O O WATER OR POTABLE WATER MAINS SHALL BE MINIMUM OF SIX (6) FEET. WHERE IT IS NECESSARY FOR A CLASS A EFFLUENT DISTRIBUTION SERVICE AND A POTABLE WATER MAIN TO CROSS A MINIMUM OF EIGHTEEN (18) 5. ALL CONTRACTORS WORKING WITHIN THE PROJECT BOUNDARIES` ARE RESPONSIBLE FOR COMPLIANCE WITH O M INCHES OF VERTICAL SEPARATION SHALL BE MAINTAINED, AND THE CROSSING SHALL BE CONSTRUCTED IN ALL APPLICABLE SAFETY LAWS OF ANY JURISDICTIONAL BODY. THE CONTRACTOR SHALL BE RESPONSIBLE 22 O a00 HALL C IN T "IDAHO RULES FOR ACCORDANCE WITH SECTION 542.07 OF THE IDAHO RULES FOR PUBLIC DRINKING WATER SYSTEMS (IDAPA FOR ALL BARRICADES, SAFETY DEVICES AND CONTROL OF TRAFFIC WITHIN AND AROUND THE J Ix a_ N 1. CONSTRUCTION OF THE WATER SYSTEMS CONFORM TO THE STANDARDS HE R LE PUBLIC DRINKING WATER SYSTEMS (IDAPA 58.01.08)" AS WELL AS THE STANDARDS AND SPECIFICATIONS 58.01.08) AND SECTION 430.02 OF THE WASTEWATER RULES (IDAPA 58.01.016). CONSTRUCTION AREA. 3 p 2 t 00 REFERRED TO IN GENERAL CONSTRUCTION NOTE NO. 1. 6. THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE SHOWN IN AN APPROXIMATE WAY ONLY. THE O 3 Geo 4. LABEL ALL IRRIGATION RISERS AND FAUCETS WITH DURABLE TAGS CARRYING THE WARNING CAUTION:RECYCLED � CO WATER-DO NOT DRINK, BOTH IN ENGLISH AND SPANISH. CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING z p C�,p � 2. THE HORIZONTAL SEPARATION OF POTABLE WATER MAINS AND NON-POTABLE WATER MAINS (SANITARY WORK. THE CONTRACTOR AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH OCCUR W 00 00 SEWER, STORM DRAIN, AND IRRIGATION) SHALL BE A MINIMUM OF TEN (10) FEET. WHERE IT IS TO THE BY HIS FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES. CONTACT �' I t c 5. AN APPROVED BACKFLOW PREVENTER IS REQUIRED IF RECYCLED WATER SYSTEM IS CONNECTED v fn C4 �'a C4 NECESSARY FOR A POTABLE WATER MAIN AND NON-POTABLE WATER MAIN TO CROSS WITH LESS THAN POTABLE WATER SYSTEM. THE DEVICE MUST BE APPROVED BY THE IDAHO DEPARTMENT OF ENVIRONMENTAL DIG-LINE AT 1-800-342-1585. EIGHTEEN (18) INCHES OF VERTICAL SEPARATION, THE CROSSING SHALL BE CONSTRUCTED IN a- n r¢ QUALITY (DEQ), THE CITY OF MERIDIAN WATER DEPARTMENT, AND LISTED IN THEMOST CUR ACCORDANCE WITH SECTION 542.07 OF THE IDAHO RULES FOR PUBLIC DRINKING WATER SYSTEMS IDAPA RENT VERSION OF N C)( THE LIST OF APPROVED BACKFLOW PREVENTION ASSEMBLIES PUBLISHED BY THE FOUNDATION FOR o Z Z 58.01.08) AND SECTION 430.02 OF THE WASTEWATER RULES (IDAPA 58.01.16). CROSS-CONNECTION CONTROL AND HYDRAULIC RESEARCH, UNIVERSITY OF SOUTHERN CALIFORNIA (USC). Ci 3. THE HORIZONTAL SEPARATION OF NON-POTABLE SERVICES AND POTABLE WATER SERVICES OR POTABLE 6. THE PUBLIC WORKS DEPARTMENT SHALL INSPECT ALL RECYCLED WATER DISTRIBUTION MAINS AND/OR SERVICES. z WATER MAINS SHALL BE A MINIMUM OF SIX (6) FEET. WHERE IT IS NECESSARY FOR A POTABLE WATER O FORTY-EIGHT (48) HOURS ADVANCE NOTICE IS REQUIRED. p MAIN AND NON-POTABLE WATER MAIN TO CROSS WITH LESS THAN EIGHTEEN (18) INCHES OF VERTICAL p m SEPARATION, THE CROSSING SHALL BE CONSTRUCTED IN ACCORDANCE WITH SECTION 542.07 OF THE z ° IDAHO RULES FOR PUBLIC DRINKING WATER SYSTEMS (IDAPA 58.01.08) AND SECTION 430.02 OF THE WASTEWATER RULES (IDAPA 58.01.16). 4. PLACE WATER SERVICE LINES IN A TWO (2) INCH DIAMETER PIPE SLEEVE WHEREVER THE SERVICE LINE CROSSES A STORM WATER TREATMENT FACILITY (I.E., SEEPAGE BEDS, DRAINAGE SWALES). 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING CONTINUOUS WATER SERVICE TO ALL EXISTING WATER USERS AFFECTED BY CONSTRUCTION. IF WATER SERVICE MUST BE INTERRUPTED, THE CONTRACTOR SHALL COORDINATE WITH THE PUBLIC WORKS INSPECTOR. L 6. WATER SERVICES SHALL BE 3/4" DOUBLE SERVICE, WITH 3/4" WATER METERS, & 3/4" DOUBLE METER if C - SETTER, CONSTRUCTED PER MERIDIAN SUPPLEMENTAL SPECIFICATIONS TO THE ISPWC, SD-W1 SD-W3. ALL ' LID COVERS SHALL BE TRAFFIC RATED. 1'. O F- � W PRESSURIZED IRRIGATION J © � 1. THE PRESSURIZED IRRIGATION SYSTEM MUST BE BUILT TO THE STANDARDS OF THE IRRIGATION DISTRICT �, t� �,,. O IN WHICH IT IS BEING CONSTRUCTED. Ld 2. INSTALL A REDUCED PRESSURE BACKFLOW PREVENTER IN ANY CONNECTION BETWEEN THE POTABLE iz O WATER SYSTEM AND THE PRESSURE IRRIGATION SYSTEM. THE SYSTEM MUST BE APPROVED BY THE .,.1 Z IDAHO DEPARTMENT OF ENVIRONMENTAL QUALITY (DEQ) AND THE CITY OF MERIDIAN WATER DEPARTMENT. .41C W o � Z