Loading...
Landscape Plan Revised M L LANDSCAPE NOTES: TREE MITIGATION NOTES: TREE PROTECTION NOTES: 1. CONTRACTOR SHALL REPORT TO LANDSCAPE ARCHITECT ALL FOR EACH CALIPER INCH OF TREE REMOVED,AN EQUIVALENT AMOUNT OF CALIPER INCHES SHALL BE 1. PROTECT THE CRITICAL ROOT ZONE(THE AREA DIRECTLY BELOW THE DRIPLINE OF THE TREE)OF THE CONDITIONS WHICH IMPAIR AND/OR PREVENT THE PROPER EXECUTION REPLANTED. TREES TO REMAIN ON SITE BY: OF THIS WORK, PRIOR TO BEGINNING WORK. a. CONSTRUCTING A TEMPORARY CHAINLINK FENCE AROUND THE CRITICAL ROOT ZONE OF THE 2. NO MATERIAL SUBSTITUTIONS SHALL BE MADE WITHOUT THE TREES WERE INVENTORIED BY JOSHUA RENNAKER, ISA CERTIFIED ARBORIST(PN-7086A) TREE TO BE PROTECTED PRIOR TO DEMOLITION,CONSTRUCTION,OR ANY SITE WORK.AS SHOWN LANDSCAPE ARCHITECT'S PRIOR WRITTEN APPROVAL. ALTERNATE ON PLANS. MATERIALS OF SIMILAR SIZE AND CHARACTER MAY BE CONSIDERED IF 1. EXISTING TREES TO BE SAVED ON SITE: b. NOT ALLOWING COMPACTION BY EQUIPMENT TRAFFIC DURING CONSTRUCTION OR DURING SPECIFIED PLANT MATERIALS CAN NOT BE OBTAINED. DEMOLITION. 3. COORDINATE ALL WORK WITH ALL OTHER SITE RELATED DEVELOPMENT -(1)24"CAL.WALNUT C. NOT ALLOWING CONCRETE TRUCKS TO RINSE WITHIN THE PROTECTION AREA,OR ANYWHERE DRAWINGS. -(1)20"CAL.SPRUCE NEAR EXISTING TREE ROOTS OR IN PLANNED PLANTING BEDS AREAS. SEE EROSION AND 4. COORDINATE WORK SCHEDULE AND OBSERVATIONS WITH LANDSCAPE -(1)2"CAL. MAPLE SEDIMENT CONTROL PLAN FOR APPROVED CONCRETE WASHOUT AREAS. ARCHITECT PRIOR TO CONSTRUCTION START-UP. -(1) 18"CAL.AUSTRIAN PINE d. NOT STOCKPILING MATERIALS, DEBRIS,OR DIRT WITHIN THE TREE PROTECTION AREA. K 5. ALL PLANT MATERIAL SHALL BE INSTALLED AS PER DETAILS. -(1) 18"CAL. HONEYLOCUST e. WATERING WITHIN THE CRITICAL ROOT ZONE FROM MID-APRIL TO MID-OCTOBER AT THE RATE OF 6. ALL PLANT MATERIAL SHALL CONFORM TO THE AMERICAN -(1)6"CAL. CHOKECHERRY NOT LESS THAN THE EQUIVALENT OF 1-1/2"OF WATER OVER THE ENTIRE AREA PER WEEK. NURSERYMAN STANDARDS FOR TYPE AND SIZE SHOWN. PLANTS WILL f. NOT TRENCHING, EXCAVATING, FILLING,OR OTHERWISE DISTURBING THE SOIL WITHIN THE BE REJECTED IF NOT IN A SOUND AND HEALTHY CONDITION. TOTAL CALIPER INCHES SAVED =88 CALIPER INCHES CRITICAL ROOT ZONE. 7. IN THE EVENT OF A PLANT COUNT DISCREPANCY, PLANT SYMBOLS g. ADJUST PROPOSED IMPROVEMENT LOCATIONS AS REQUIRED TO AVOID DAMAGING TREE ROOTS. SHALL OVERRIDE SCHEDULE QUANTITIES AND CALL OUT SYMBOL 2. EXISTING TREES TO BE REMOVED ON SITE: 2. PROTECT THE CROWN AND TRUNK OF TREES TO BE RETAINED BY: NUMBERS. -(1)20"CAL.SPRUCE, MITIGATION REQUIRED a. OPERATING EQUIPMENT IN SUCH A WAY AS TO AVOID CONTACT WITH TREE TRUNKS OR 8. ALL PLANTING BEDS SHALL BE COVERED WITH A MINIMUM OF 3"DEPTH -(1)6"CAL. PONDEROSA PINE, MITIGATION REQUIRED BRANCHES. OF SOIL AID MULCH OR 3/4"MINUS BLACK AND TAN PERMABARK ROCK b. HAVING TREES PRUNED BY A LICENSED ARBORIST. MULCH PER PLANS,OVER TOPSOIL AS SPECIFIED.SUBMIT SAMPLE FOR -(1)2"CAL. MAPLE(UNDER 4", NO MITIGATION REQUIRED) C. WHERE EXCAVATION FOR NEW CONSTRUCTION IS REQUIRED WITHIN TREE PROTECTION ZONES APPROVAL. -(1)4"CAL.VANDERWOLF PINE, MITIGATION REQUIRED AND APPROVED, HAND PRUNE OR UTILIZE ROOT PRUNING TECHNIQUES DESCRIBED BELOW 9. ALL PLANT MATERIAL SHALL BE GUARANTEED FOR A PERIOD OF ONE -(1)2"CAL.APRICOT(UNDER 4", NO MITIGATION REQUIRED) PRIOR TO EXCAVATION. YEAR BEGINNING AT THE DATE OF ACCEPTANCE BY THE OWNER -(1)2"CAL. CRABAPPLE(UNDER 4"/1DEAD, NO MITIGATION REQUIRED) d. ROOT PRUNING:WHERE REQUIRED AND APPROVED,SHALL BE DONE MECHANICALLY WITH A REPLACE ALL PLANT MATERIAL FOUND DEAD OR NOT IN A HEALTHY -(1)2"CAL. PEAR(UNDER 4"/DEAD, NO MITIGATION REQUIRED) ROOT PRUNING MACHINE,VIBRATORY PLOW,OR WITH A NARROW TRENCHER WITH SHARP CONDITION IMMEDIATELY WITH THE SAME SIZE AND SPECIES AT NO -(1)2"CAL. DOGWOOD(UNDER 4"/DEAD, NO MITIGATION REQUIRED) BLADES.ONCE A TRENCH IS OPENED UP,ALL EXPOSED ROOTS WILL BE HAND PRUNED TO CA LOUT NUMBERS COST TO THE OWNER. -(1)4"CAL. HONEYLOCUST, MITIGATION REQUIRED PROVIDE CLEAN-CUT ENDS. CALLOUT NOTES NOTES BELOW NOUVMBERED PROJECT INFORMATION 10. FINISH GRADES SHALL PROVIDE A SMOOTH TRANSITION WITH -(2)2"CAL. LINDEN (UNDER 4"/DEAD, NO MITIGATION REQUIRED) e. DO NOT CUT MAIN LATERAL ROOTS OR BUTTRESS ROOTS;CUT ONLY SMALLER ROOTS THAT ADJACENT SURFACES AND ENSURE POSITIVE DRAINAGE IN -(2)2"CAL.WEEPING WHITE PINE(UNDER 4"/DEAD, NO MITIGATION REQUIRED) INTERFERE WITH INSTALLATION OF UTILITIES.CUT ROOTS WITH SHARP PRUNING INSTRUMENTS; 1. VISION TRIANGLE. LANDSCAPE REQUIREMENTS ACCORDANCE WITH THE SITE GRADING PLAN. DO NOT BREAK OR PULL WITH BACKHOE OR SIMILAR EQUIPMENT. -(1)4"CAL.AUSTRIAN PINE, MITIGATION REQUIRED f. TREE PRUNING:TREES TO REMAIN THAT ARE AFFECTED BY TEMPORARY AND PERMANENT 2. EXISTING 4'TALL WOOD POST/WIRE FENCE TO 11. AMEND EXISTING APPROVED TOPSOIL AT A RATIO OF THREE CUBIC -(1)2"CAL. OAK, (UNDER 4", NO MITIGATION REQUIRED) CONSTRUCTION SHALL BE PRUNED AS INDICATED. REMAIN. TOTAL PROPERTY SIZE= 31,954.46 S.F.- .73 ACRES YARDS OF APPROVED COMPOST PER 1000 SQUARE FEET. ROTO-TILL ZONING DISTRICT= R-8 ORGANIC MATTER A MINIMUM OF 6 INCHES INTO TOPSOIL. -(1)2"CAL. MAPLE, (UNDER 4"/DEAD, NO MITIGATION REQUIRED) g. PRUNING STANDARDS: PRUNE TREES ACCORDING TO CURRENT ANSI A300 PRUNING STANDARDS. 3. EXISTING 6'TALL VINYL FENCE IN ALMOND COLOR TO 12. FERTILIZE ALL TREES AND SHRUBS WITH'AGRIFORM'PLANTING REMAIN. TABLETS. QUANTITY PER MANUFACTURER'S RECOMMENDATIONS. TOTAL CALIPER INCHES REMOVED =60 CALIPER INCHES 3. REGRADING-GRADING LIMITATIONS WITHIN THE TREE PROTECTION ZONE 4. EXISTING SIDEWALK TO REMAIN. TOTAL NUMBER OF TREES:27(6 EXISTING) 13. ALL PLANTING BEDS SHALL HAVE A MINIMUM 18"DEPTH OF TOPSOIL. TOTAL CALIPER INCHES THAT DO NOT REQUIRE MITIGATION=22 CALIPER INCHES a. GRADE CHANGES WITHIN THE TREE PROTECTION ZONE ARE NOT PERMITTED. 5. NOT USED. TOTAL NUMBER OF TREE SPECIES:4+; 3 SPECIES REQUIRED H LAWN AREAS SHALL HAVE A MINIMUM 12"DEPTH OF TOPSOIL. SPREAD, TOTAL CALIPER INCHES THAT REQUIRE MITIGATION =38 CALIPER INCHES b. GRADE CHANGES OUTSIDE THE TREE PROTECTION ZONE SHALL NOT SIGNIFICANTLY ALTER 6. EXISTING 6'TALL VINYL FENCE TO BE REMOVED. COMPACT,AND FINE GRADE TOPSOIL TO A SMOOTH AND UNIFORM DRAINAGE. 7. EXISTING HOUSE TO BE REMOVED. LANDSCAPE BUFFER REQUIREMENTS: GRADE 3"BELOW ADJACENT SURFACES OF PLANTER BED AREAS, 1-1/2" C. GRADE CHANGES UNDER SPECIFICALLY APPROVED CIRCUMSTANCES SHALL NOT ALLOW MORE NORTH LANDSCAPE BUFFER(RESIDENTIAL SUBDIVISION): METHODS OF MITIGATION TO INCLUDE UPSIZING CODE REQUIRED FIVE(5)STREET TREES TO 3"CALIPER 8. EXISTING DRIVEWAY TO BE REMOVED. BELOW ADJACENT SURFACES OF TURF SOD AREAS,AND 1"BELOW AND PROPOSING ONE(1)ADDITIONAL UPSIZED STREET TREE THAN WHAT IS REQUIRED PER CODE. ALSO, THAN 6 INCHES OF FILL SOIL OR ALLOW MORE THAN 4 INCHES OF EXISTING SOIL TO BE REMOVED 9. EXISTING ASPHALT SPORTS COURT TO BE REMOVED. 179.7 LINEAR FT. ADJACENT SURFACES OF TURF SEED AREAS. FROM NATURAL GRADE, UNLESS MITIGATED. 10 FT.WIDE LANDSCAPE BUFFER PROVIDED 14. REUSE EXISTING TOPSOIL STOCKPILED ON THE SITE. SUPPLEMENT PROPOSING AN ADDITIONAL FIFTEEN (15)2"CALIPER TREES(ASSUMES 6'HGT.CONIFER EQUALS 2"CAL. d. GRADE FILLS OVER 6 INCHES OR IMPERVIOUS OVERLAY SHALL INCORPORATE AN APPROVED REQUIRED TREES-0 DECIDUOUS)ON-SITE THAN WHAT IS REQUIRED PER CODE. PROPOSING TWELVE(12)DECIDUOUS TREES PERMANENT AERATION SYSTEM, PERMEABLE MATERIAL,OR OTHER APPROVED MITIGATION. WITH IMPORTED TOPSOIL WHEN QUANTITIES ARE INSUFFICIENT. AT INTERIOR OF SITE AND THREE(3)CONIFEROUS TREES AT WEST PROPERTY BOUNDARY. e. GRADE CUTS EXCEEDING 4 INCHES SHALL INCORPORATE RETAINING WALLS OR AN APPROPRIATE PROVIDED TREES 1 EXISTING) VERIFY SUITABILITY AND CONDITION OF TOPSOIL AS A GROWING SOUTH LANDSCAPE BUFFER (E. ROSALYN DR.): MEDIUM. PERFORM SOIL TEST/ANALYSIS AND PROVIDE ADDITIONAL TRANSITION EQUIVALENT. AMENDMENT AS DETERMINED BY SOIL TESTS. TOPSOIL SHALL BE A -UPSIZING FIVE(5)REQUIRED STREET TREES FROM 2"TO 3"CALIPER=5 CALIPER INCHES 179.1 LINEAR FT. LOOSE, FRIABLE,SANDY LOAM,CLEAN AND FREE OF TOXIC MATERIALS, -PROPOSE ONE(1)ADDITIONAL UPSIZED STREET TREE=3 CALIPER INCHES 4. ALL TREES THAT ARE DAMAGED, DESTROYED OR REMOVED DURING CONSTRUCTION SHALL BE 10 FT.WIDE LANDSCAPE BUFFER PROVIDED NOXIOUS WEEDS,WEED SEEDS, ROCKS,GRASS OR OTHER FOREIGN -PROPOSE ADDITIONAL FIFTEEN (15)2"CALIPER TREES ON-SITE=30 CALIPER INCHES MITIGATED USING THE MITIGATION STANDARDS PER THE MERIDIAN CITY CODE AS PER SECTION LANDSCAPE LEGEND (10 FT.WIDE LANDSCAPE BUFFER REQUIRED) MATERIAL AND A HAVE A PH OF 5.5 TO 7.0. IF ONSITE TOPSOIL DOES 11-313-10. 1 TREE PER 35 LINEAR FEET. G NOT MEET THESE MINIMUM STANDARDS,CONTRACTOR IS TOTAL CALIPER INCHES PROVIDED FOR MITIGATION =38 CALIPER INCHES REQUIRED TREES-5 RESPONSIBLE TO EITHER: 5. SEE TREE MITIGATION NOTES FOR ADDITIONAL INFORMATION. PROVIDED TREES-6(1 FOR TREE MITIGATION) A)PROVIDE APPROVED IMPORTED TOPSOIL,OR EAST LANDSCAPE BUFFER(RESIDENTIAL SUBDIVISION): B)IMPROVE ON-SITE TOPSOIL WITH METHODS APPROVED BY THE + + PLANTS TO BE INSTALLED 185.3 LINEAR FT. LANDSCAPE ARCHITECT. 5 FT.WIDE LANDSCAPE BUFFER PROVIDED 15. IF IMPORTED TOPSOIL FROM OFF-SITE SOURCES IS REQUIRED, ENSURE REQUIRED TREES-0 IT IS FERTILE, FRIABLE, NATURAL LOAM,SURFACE SOIL, REASONABLY PROVIDED TREES-0 FREE OF SUBSOIL,CLAY LUMPS, BRUSH,WEEDS AND OTHER LITTER, EXISTING TREES TO BE REMOVED WEST LANDSCAPE BUFFER(RESIDENTIAL SUBDIVISION): AND FREE OF ROOTS,STUMPS,STONES LARGER THAN 2 INCHES IN ANY LARKSPUR SUBDIVISION NO. 2 4 DIMENSION,AND OTHER EXTRANEOUS OR TOXIC MATTER HARMFUL TO BOOK 97 PAGES 12,314-12,317 5 FT. LINEAR FT. PLANT GROWTH. 3 5 FT.WIDE LANDSCAPE BUFFER PROVIDED A) OBTAIN TOPSOIL FROM LOCAL SOURCES OR FROM AREAS HAVING N89`44'39"E 179.66' REQUIRED TREES-0 F SIMILAR SOIL CHARACTERISTICS TO THOSE FOUND ON THE PROJECT BEGIN X + + + X. + + + + + + + + + + + + + X ° PROVIDED TREES-3(3 FOR TREE MITIGATION) SITE. OBTAIN TOPSOIL ONLY FROM NATURALLY,WELL-DRAINED 6 4 EXISTING TREES TO BE RETAINED + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + W + + + + + + + + + + + + + + + + SITES WHERE TOPSOIL OCCURS AT A DEPTH OF NOT LESS THAN 4 2 + + + + + + + " + + ��+ + + + + + + W 1 + + + + + + 4" + + + +2" + + + + INCHES. BEGIN + + W + + W + + + W + + + + + + + + •-8 W W W W N W W W W W W W W W B) REPRESENTATIVE SAMPLES SHALL BE TESTED FOR ACIDITY, ��- �..... .---.- --•••••• - - �--� -� . .. .. " -------------- PLANTER BED CUT EDGE AS DETAILED 2 I I''' f ----- DEVELOPER FERTILITY,TOXICITY,AND GENERAL TEXTURE BY A RECOGNIZED + + I':' „ I + + + + » 1 +I+ + I.. B-B ROSALYN LLC COMMERCIAL OR GOVERNMENT AGENCY AND COPIES OF THE + W + i+ + + + + + + + +I 2 - r'. PROPERTY LINE(VERIFY) 208-860-6207 TESTING AGENCY'S FINDINGS AND RECOMMENDATIONS SHALL BE + I' FURNISHED TO THE OWNER'S REPRESENTATIVE BY THE I'' ..I._ J`I + + + I:: I 2 y 2400 W.WAPOOT DRIVE ..... ...... ..... ..... + h. :::'::' I +I':: :. MERIDIAN, ID 83646 CONTRACTOR. NO TOPSOIL SHALL BE DELIVERED IN A FROZEN OR + r•. j + + +o +18�� h.. I MUDDY CONDITION.ACIDITY/ALKALINITY RANGE-PH.5.5 TO 7.6. + + I. 16. IMMEDIATELY CLEAN UP ANY TOPSOIL OR OTHER DEBRIS ON THE SITE I.. ® .. -.- ..-.... ....-A. rl..... ...... CREATED FROM LANDSCAPE OPERATIONS AND DISPOSE OF PROPERLY f: 3 E OFF SITE. + W + r 5.121 4,453 � X2" �W 17. TREES SHALL NOT BE PLANTED WITHIN THE 10'-0"CLEAR ZONE OF ALL W + SQ FT SQ FT 4,478 . : :: � PLANT SCHEDULE A.C.H.D.STORM DRAIN PIPE, STRUCTURES,OR FACILITIES. TREES SQ FT SHALL NOT BE PLANTED WITHIN 5'-O"OF AN A.C.H.D.SIDEWALK. + + I : ::':::'� 18. SEEPAGE BEDS AND OTHER STORM DRAINAGE FACILITIES MUST BE I �. ;�...:;.:. PROTECTED FROM ANY AND ALL CONTAMINATION DURING THE 1......: SYMBOL QTY COMMON / BOTANICAL NAME PLANTING SIZE MATURITY SIZE CLASS CONSTRUCTION AND INSTALLATION OF THE LANDSCAPE IRRIGATION W SYSTEM. ...... ..... o. Q 19. IN THE EVENT OF A DISCREPANCY, NOTIFY THE LANDSCAPE ARCHITECT + + I:': + + + :: .:. ::. :::.:::......:.: : :: CONIFEROUS TREES o L _ _._.t g + _ -.-. .. IMMEDIATELY. I.'. - L+--+ +-+ + + + + W + �. •yu + + + + + + W Columnar Norway Spruce NO. REVISION/ISSUE DATE D + + W + + �• 3 6� Ht. 25�Hx6�W SAN GORGONIO SUBDIVISION Picea abies 'Cupressina' 6 IRRIGATION NOTES• '�" .O.. 1. W + + + W O W + + + + + + + W + W + + + + + BOOK 118 PAGES 18,079-18,081 rn D EDMONDS SUBDIVISION N BOOK 33 PAGES 2,050-2,051 W + W + + m 0 1. ALL LANDSCAPED AREAS SHALL HAVE AN AUTOMATIC UNDERGROUND + + + '' 4 SPRINKLER SYSTEM WHICH INSURES COMPLETE COVERAGE AND PROPERLY + + w DECIDUOUS TREES o°°�E OF 1�O0% 811 . o i ZONED FOR REQUIRED WATER USES. EACH HYDROZONE IS TO BE IRRIGATED + + U o00 �p Oq�o000 WITH SEPARATE INDIVIDUAL STATIONS. + + + S o00 6 R• RF O oo N + + „P S S COMMON LOT Princeton Sentry Maidenhair Tree o JP �'�j. oo 2. PLANTER BEDS AND LAWN AREAS ARE TO HAVE SEPARATE HYDRO-ZONES. 0 6 2" Cal. B&B 40 H X 15'W Class II o* 9 *o Knawbelow w 4,4ss SQ FT o Ginkgo biloba'Princeton Sentry' o o �, you g 3. POP-UP SPRINKLER HEADS SHALL HAVE A MINIMUM RISER HEIGHT OF 4 INCHES g y or- I-o Call before dig. L AT LAWN AREAS AND 18"AT PLANTER BEDS. z + + + + + + + + N + o- A c�o CALL 2 BUSINESS DAYS EF on L'-lo IN ADVANCE BEFORE o 4. PLANTER BEDS ARE TO HAVE DRIP IRRIGATION SYSTEM OR POP-UP SPRAY or^ LA-16848 do + + + + + + + + + + + + + + + + + /� O YOU DIG,GRADE,OR U o SYSTEM.ANNUALS, PERENNIALS GROUND COVERS OR SHRUB MASSINGS + + + + + + + + + + + + + + + + + + + + + + + + Skyline Honeylocust 000J' moo EXCAVATE FOR THE SHALL HAVE APOP-UP SPRAY SYSTEM. 6 3 Cal. B&B 45 H X 35 W Class II of �V oo MARKING OF N W F_W W W W W W W W W W�W W W WO W W W W W W W W OY W W T Gleditsia triacanthos'Skycole' OoO P Q UNDERGROUND -p 5. ELECTRONIC WATER DISTRIBUTION/TIMING CONTROLLERS ARE TO BE + W + + + + + + + + + + + + + + + + + + + + + + + + +�+ + + + + + + + + + + + +X+ + + + + + + + 000°�a�opooOo�°��oo MEMBER UTILITIES T C PROVIDED. MINIMUM CONTROLLER REQUIREMENTS AREAS FOLLOWS: + + I] + + + +r, k -. ,- -� �.-,y,-. -, W % ! --+-- . .w. .... .w-• r*t a. PRECISE INDIVIDUAL STATION TIMING ° + + 2O W + + b. RUN TIME CAPABILITIES FOR EXTREMES IN PRECIPITATION RATES :.I ""•� :; + .I� FLOWERING TREES o c. AT LEAST ONE PROGRAM FOR EACH HYDROZONE d. SUFFICIENT MULTIPLE CYCLES TO AVOID WATER RUN-OFF j f'. 7 I + + 9 : w z ..� ••I,y , Red Barron Crabapple � o e. POWER FAILURE BACKUP FOR ALL PROGRAMMED INDIVIDUAL VALVE + + + 4,060 / + :1 -- 6 2 Cal. B&B 18 H X 8 W Class I H E~ I. - + I Malus x Red Barron �- z WATERING STATIONS WILL BE DESIGNED AND INSTALLED TO PROVIDE +24 +/: SQ FT + yl.'. 1 I + U v w + WATER TO RESPECTIVE HYDRO-ZONES. 6. INDIVIDUAL VALVE WATERING STATIONS WILL BE DESIGNED AND INSTALLED TO + + f. :w yl','. 4,12 I A + + + + Q FT / U PROVIDE WATER To RESPECTIVE HYDRO-ZONES. I � �.� W '�� I•: SYMBOL QTY COMMON / BOTANICAL NAME PLANTING SIZE MATURITY SIZE NOTES 7. THE IRRIGATION SYSTEM SHALL BE DESIGNED TO PROVIDE 100%HEAD TO HEAD COVERAGE WITH TRIANGULAR SPACING. END 8. SPRINKLER HEADS SHALL BE ADJUSTED TO REDUCE OVER SPRAY ONTO W y ::I a + + O �o SHRUBS v z a x w �: B IMPERVIOUS SURFACES(BUILDINGS,SIDEWALKS, DRIVEWAYS,AND ASPHALT 2 i W I,',' + J+ Ca w Z O „ 1 20 Green Velvet Boxwood 2 Gal. 3'H x 3'W a AREAS). 20 "'I :.1 "' � I `+ �W W L y WI + + + //" Buxus x Green Velvet RODNEY EVANS + PARTNERS a + + + + a 9. PROVIDE MINIMUM(1)QUICK COUPLER VALVE PER EACH(6)AUTOMATIC VALVE -X- - -�,�: , y 1... :,:j + , F::: 5,219 ::� - o ZONES. APPROVE Q.C.V. LOCATIONS WITH LANDSCAPE ARCHITECT. + \+• SQ FT .''I+ Fine Line Fern Leaf Buckthorn reandpartners.com+208-514-3300+1450 W.Bannock Street,Boise,Idaho 83702 ..I + + o ) 6 5gal. 6'Hx3'W o *+ W W I.. L Wi.. + �� �t Rhamnus frangula Ron Williams 3 + + �'i W I.. .:. + + �" PERENNIALS ROSALYN SUBDIVISION ' + + J + + WI + + C-D + + + W , �' W �.. . I + m Chicago Apache Daylily a + .. .. + + \.. ....... ... ... ... .. :. JW y + + - --- > 19 1 gal. 2 H x 2'W 4 -- L+- + + + + + + + + • L Hemerocallis x'Chicago Apache' 200E ROSALYN DR o \ + + + + T + \ \ \ W + + + W + + +++ MERIDIAN IDAHO \\ \ W W J + + + ++ + + + + �y + + Y + + + + + + + + + N + + + + + + W + + + + + t + + + + + SYMBOL QTY COMMON / BOTANICAL NAME SIZE NOTES SUBDIVISION 4 3 --- GROUND COVERS \ \\ - ° - - - - 4 - - + W � W + + 10,695sf RTFSod -_ LANDSCAPE PLAN CE m - - - - - - - - -W 6 Rhizomatous Tall Fescue L - I- - - - - - - - - - - - - - - - - -1 - - - - -w•CD - - �- - - 1 EAST ROSALYN DRIVE - MULCH PROJECT SHEET _ - - 3/4 Black and Tan Perma Bark 23072 Q S 0 S - - - - 2,951 sf co o Rock Mulch N ...................... 0 0 LANDSCAPE PLAN DATE 2/22/2024 Ll . 0 it 20 0 20 40 60 DRAWN BY CHECKED BY Q N SCALE: 1"=20'-0" J R J R U 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 PRE-PLAT/FINAL PLAT SUBMITTAL