PZ - Revised Exterior Elevations TEMPERED GLAZING REQ'S c ) \lk
G.C.TO PROVIDE AS NOTED BELOW,TYP. C H I P M A N D E S I G N
ARCHITECTURE GROUP PC
1. AT PANELS ADJACENT TO DOORS, WITHIN 24" OF DOOR EDGE, AND 1 3 5 0 E T 0 U H Y AV E
WHERE BOTTOM EDGE IS LESS THAN 60" ABOVE WALKING SURFACE. F I R S T F L O O R E A S T
DES PLAINES, IL 60018
2. WHERE AN INDIVIDUAL PANEL IS GREATER THAN 9 SQ.F. T E L 8 4 7 . 2 9 8 6 9 0 0
3. WHERE BOTTOM EDGE IS LESS THAN 18" A.F.F.
1 MTL-1 ES-1 ES-2
4. WHERE TOP EDGE IS GREATER THAN 36"AFF AND WALKING SURFACE
IS WITHIN 36" HORIZONTALLY OF THE PLANE OF THE GLAZING.
AC-1
5. GLAZING ADJACENT TO STAIRWAYS, LANDINGS AND RAMPS WITHIN
2T-6" 36" HORIZONTALLY OF WALKING SURFACE.
T/HIGH PARAPET 6. FIRE DEPT. GLASS ACCESS PANELS SHALL BE TEMPERED GLASS.
22'-0"
T/ PARAPET
a:�� nooidles
& COMPANY CMU WALL ELEVATION GENERAL NOTES
16'-6" S401 1. GC TO ENSURE PHYSICAL BARRIER BETWEEN DISSIMILAR METAL TO
T/ ROOF 1 PROTECT AGAINST ELECTROLYTIC ACTION BETWEEN METALS.
ES-1 I 2. NEW SIGNAGE UNDER SEPARATE PERMIT. GC TO VERIFY&
MANUAL-CLOSING COORDINATE WITH SIGN COMPANY MOUNTING HEIGHTS &SUPPORT
6'-11 5/8" BRICK VENEER WINDOW QUIKSERV REQUIREMENTS PRIOR TO BLOCKING INSTALLATION. GC TO PROVIDE
13'-0" T/OPENING MODEL#BPSC-4836 & INSTALL BLOCKING &ACCESS PANELS AS NECESSARY.ALLOW FOR
T/STOREFRONT CAULK AND SEAL AS THRU-BOLTING AT MASONRY WALL CONSTRUCTION. IT SHALL BE
REQUIRED. SOLELY THE RESPONSIBILITY OF THE SIGN CONTRACTOR TO FABRICATE
SELF-CLOSING WINDOW, AND INSTALL ALL SIGNAGE UNDER SEPARATE PERMIT. SIGNAGE
QUIKSERV MODEL#BPSC-4836 SHOWN FOR SCHEMATIC AND COORDINATION PURPOSES ONLY.
9'-6" SHIM W/BACKROD AND
B/STOREFRONT 2 SEALANT ON EACH SIDE. 3. GC TO CLEAN, PATCH, PAINT& REPAIR EXISTING EXTERIOR FACADE AS
A2.10 1/2" FRT PLYWOOD REQUIRED DUE TO DAMAGE DURING DEMOLITION AND/OR NEW
CONSTRUCTION,TYP.
� 7'-2" f 1 � 3'-6"
T/STOREFRONT T-6" BRICK VENEER INFILL B/OPENING 4. GC TO COORDINATE LOCATION AND TYPE OF KNOX BOX WITH
ES-1 B/OPENING TO MATCH I NOODLES & CO PM AND LOCAL FIRE DEPARTMENT.
WALL CONSTRUCTION EXTERIOR WALL
CONSTRUCTION 5. ADDRESS NEEDS TO BE VISIBLE FROM THE STREET APPROACH. VERIFY
2 4 FLASHING WEEPHOLES LOCATION AND REQUIREMENTS W/LOCAL FIRE DEPARTMENT PRIOR
TO THE START OF CONSTRUCTION.
11-11 ------ CONTINUOUS FLASHING
6. GC SHALL COORDINATE WITH SIGN INSTALLER REGARDING LOCATIONS
CONTINUOUS 2X BLOCKING. OF INTERIOR STRUCTURAL ITEMS AND ELECTRICAL RUNS&OUTLETS
PRIOR TO START OF SIGNAGE INSTALLATION.
0'-0"
T/SLAB _ 0'-0"
T/SLAB
STF-1 ES-2 BK-1
)i
r-I
KEYNOTES O 0
0
0
1. NOODLES STOREFRONT SIGNAGE CO
4 EXTERIOR ELEVATION - WEST r3 DRIVE THRU WINDOW SECTION 2 DRIVE THRU SILL DETAIL o
J10
1/4" = V-0" A2.10 1/4" = V-0" A2.10 1 1/2" = 1'-0" X
W
LL
zW 2
MTL-1 ES-1 ES-2 MTL-1 ES-1 ES-2 Q > 0
MTL-1 AC-1 EXTERIOR FINISH SCHEDULE m
2T-6" 0 0 0
TAG MATERIAL DESCRIPTION
T/ HIGH PARAPET U z W
22 -0 AC-1 ALUMINUM SIDING DARK NATIONAL WALNUT J M ~
p� _ oo p
T/ PARAPET cn
AC-2 ALUMINUM SIDING CANOPY-COLOR TO MATCH DUNN (.f) — ,maxo
EDWARDS 6049: "CHAPS" w c
J w Q w
ES-1 EIFS SYSTEM -SMOOTH CANOPY-COLOR TO MATCH DUNN z
STUCCO FINISH EDWARDS 6172: "BUNGALOW TAUPE 0 �: Q Q Q
16'-6" I ES-2 EIFS SYSTEM -SMOOTH CANOPY-COLOR TO MATCH DUNN 0 f� 0 N
T/ ROOF STUCCO FINISH EDWARDS 6149. LONELY ROAD 0 0 0
cW �
ES-1 ES-1 MTL-1 PREFINISHED METAL COPPER BROWN FINISH Z M C 0 �
O O
STF-1 ALUMINUM WINDOW SYSTEM MEDIUM BRONZE FINISH PROJECT NUMBER:
WITH INSULATED GLASS (G-1) 21-1876.00
CMU-1 CMU 8X8X16 UMBER BROWN, SPLIT FACE, ISSUA NS
RUNNING BOND
3 BK-1 BASE ROCK FACE SILL COMMERCIAL GRADE, COLOR:
A2.lur WHITE, RICL FACE SILL 8X4X16 WITH
AC-2 CHAMFERED EDGE
V
T/STOREFRONT O ES-1 ES-1 O \\ \\ \\ \\
00 DRAWN BY: CHECKED BY:
0'-0" JD xx
T/SLAB
ES-2 BK-1 BK-1 ES-2 STF-1 STF-1
EXTERIOR ELEVATIONS
SHEET:
1 EXTERIOR ELEVATION - SOUTH
J10 1/4" = V-0"
A2elO_
EXTERIOR FINISH SCHEDULE TEMPERED GLAZING REQ'S \lk
TAG MATERIAL DESCRIPTION G.C.TO PROVIDE AS NOTED BELOW,TYP.
CH I P M A N DESIGN
ARCHITECTURE GROUP PC
AC-1 ALUMINUM SIDING DARK NATIONAL WALNUT 1. AT PANELS ADJACENT TO DOORS, WITHIN 24" OF DOOR EDGE, AND
WHERE BOTTOM EDGE IS LESS THAN 60" ABOVE WALKING SURFACE. 1 3 5 o E T 0 Y A S E
0 R
FIRST F L O E A T
AC-2 ALUMINUM SIDING CANOPY-COLOR TO MATCH DUNN EDWARDS 6049: "CHAPS" DE S P L A I N E S, I L 60018
2. WHERE AN INDIVIDUAL PANEL IS GREATER THAN 9 SQ.F. T E L : 8 4 7 . 2 9 8 . 6 9 0 0
ES-2 MTL-1 ES-1 AC-1 MTL-1 1
ES-1 EIFS SYSTEM -SMOOTH STUCCO FINISH CANOPY-COLOR TO MATCH DUNN EDWARDS 6172: 3. WHERE BOTTOM EDGE IS LESS THAN 18" A.F.F.
25'-6" "BUNGALOW TAUPE"
T/ HIGH PARAPET 4. WHERE TOP EDGE IS GREATER THAN 36"AFF AND WALKING SURFACE
ES-2 EIFS SYSTEM -SMOOTH STUCCO FINISH CANOPY-COLOR TO MATCH DUNN EDWARDS 6149: "LONELY IS WITHIN 36" HORIZONTALLY OF THE PLANE OF THE GLAZING.
ROAD"
5. GLAZING ADJACENT TO STAIRWAYS, LANDINGS AND RAMPS WITHIN
MTL-1 PREFINISHED METAL COPPER BROWN FINISH 36" HORIZONTALLY OF WALKING SURFACE.
22'-0"
T/ PARAPET 6. FIRE DEPT. GLASS ACCESS PANELS SHALL BE TEMPERED GLASS.
STF-1 ALUMINUM WINDOW SYSTEM WITH INSULATED MEDIUM BRONZE FINISH
GLASS (G-1)
n ood I es MTL-1 CMU-1 CMU 8X8X16 UMBER BROWN, SPLIT FACE, RUNNING BOND
MTL-1 & COMPANY
BK-1 BASE ROCK FACE SILL COMMERCIAL GRADE, COLOR: WHITE, RICL FACE SILL 8X4X16
16'-6" WITH CHAMFERED EDGE ELEVATION GENERAL NOTES
T/ ROOF ES-1
1. GC TO ENSURE PHYSICAL BARRIER BETWEEN DISSIMILAR METAL TO
PROTECT AGAINST ELECTROLYTIC ACTION BETWEEN METALS.
13'-0" 2. NEW SIGNAGE UNDER SEPARATE PERMIT. GC TO VERIFY&
T/STOREFRONT COORDINATE WITH SIGN COMPANY MOUNTING HEIGHTS &SUPPORT
REQUIREMENTS PRIOR TO BLOCKING INSTALLATION. GC TO PROVIDE
& INSTALL BLOCKING &ACCESS PANELS AS NECESSARY.ALLOW FOR
THRU-BOLTING AT MASONRY WALL CONSTRUCTION. IT SHALL BE
SOLELY THE RESPONSIBILITY OF THE SIGN CONTRACTOR TO FABRICATE
9'-6" / / / / AND INSTALL ALL SIGNAGE UNDER SEPARATE PERMIT. SIGNAGE
B/STOREFRONT AC_2 SHOWN FOR SCHEMATIC AND COORDINATION PURPOSES ONLY.
7'-10" 3. GC TO CLEAN, PATCH, PAINT& REPAIR EXISTING EXTERIOR FACADE AS
T/CANOPY REQUIRED DUE TO DAMAGE DURING DEMOLITION AND/OR NEW
7'-2" CONSTRUCTION,TYP.
T/STOREFRONT 4. GC TO COORDINATE LOCATION AND TYPE OF KNOX BOX WITH
NOODLES & CO PM AND LOCAL FIRE DEPARTMENT.
5. ADDRESS NEEDS TO BE VISIBLE FROM THE STREET APPROACH.
VERIFY LOCATION AND REQU REM NTS W/OCAL FIRE DE ARTMENT PRIOR
TO THE START OF CONSTRUCTION.
6. GC SHALL COORDINATE WITH SIGN INSTALLER REGARDING LOCATIONS
01-01, OF INTERIOR STRUCTURAL ITEMS AND ELECTRICAL RUNS&OUTLETS
T/SLAB PRIOR TO START OF SIGNAGE INSTALLATION.
ES-2 STF-1 BK-1 ES-2 STF-1
r-I
KEYNOTES O o
r2-- EXTERIOR ELEVATION - EAST 1. NOODLES STOREFRONT SIGNAGE 00
JOO 1/4" V-0" x
x O
X
o
Lu
LL
1 MTL-1 zw 2 ES-2 ES-1 MTL-1 AC-1 < > O
25 -6
T/ HIGH PARAPET C cl:�
C � m
23'-6" O O 0
T/ HIGH PARAPET U z � W
22'-0"
T/ PARAPET J M
co _ oo p V)
� m U
o no I Lu co ul
es
MTL-1 & COMPANY J w Q w
z
�� 0 � Q J Q
16-6 I)
T/ ROOF _ O O cl:� O 0
Lu
ES-1 z M 2 L zz LNrn
13'-0" PROJECT NUMBER:
T STOREFRONT
21-1876.00
ISSUANCE/REVISIONS
9'-6"
B/STOREFRONT AC-2
7'-10"
T/CANOPY
\ ^�
7'-2" v
T/STOREFRONT // // // // \ O
/ / / / ES-1 \\
CMU-1 \ i
/
/
o'-o" 0 0
DRAWN BY: CHECKED BY:
T/SLAB
J D xx
STF-1 BK-1 ES-2 BK-1 ES-2T >j c STF-1
EXTERIOR ELEVATIONS
SHEET:
rj EXTERIOR ELEVATION - NORTH
JOO 1/4" = V-0"
A2e00