Loading...
CC - Commission Recommendation to Council and Staff Report 3-28 STAFF REPORT E IDIAN�-- COMMUNITY DEVELOPMENT DEPARTMENT I D A H O HEARING March 28,2023 Legend DATE: Project Location TO: Mayor&City Council FROM: Bill Parsons Current Planning Supervisor --- 208-884-5533 _ SUBJECT: Newkirk Neighborhood AZ, PP H-2022-0088 _ LOCATION: 4250 W.Franklin Rd.,in the SW 1/4 of Section 10,T.3N., R.1 W. (Parcel #51210346801) Bar] :._ I. PROJECT DESCRIPTION Annexation of 23.67 acres of land with a TN-R(Traditional Neighborhood Residential)zoning district; and Preliminary Plat consisting of 63 (44 single-family attached, 18 townhomes & 1 multi-family)building lots and 8 (5 landscape, 1 common driveway, 1 alley, 1 non-buildable)common lots on 21.06-acres of land in the TN-R district for Newkirk Neighborhood Subdivision. II. SUMMARY OF REPORT A. Project Summary Description Details Acreage 21.06 acres(23.67 acres-annexation area) Future Land Use Designation Medium-High Density Residential(MHDR)in the Ten Mile Interchange Specific Area Plan(TMISAP) Existing Land Use Single-family rural residential(SFR) Proposed Land Use(s) SFR attached dwellings,townhouse dwellings&multi-family development Current Zoning Rural Urban Transition(RUT)in Ada County Proposed Zoning TN-R Lots(#and type;bldg/common) 63 building/8 common lots Phasing plan(#of phases) 2(SFR/townhomes—Phase 1;multi-family—Phase 2) Number of Residential Units(type 278(44 single-family attached, 18 townhomes&216 apartments) of units) Density(gross&net) 13.2 units/acre(gross) Open Space(acres,total [%]/ 7.21 acres(or 35%)qualified buffer/qualified) Pagel Amenities Single-family area:play structure,swings,(2)seating areas, (2)shade structures,climbing rocks and a climbing dome. Multi-family area: clubhouse,fitness center,enclosed bike storage,dog park with waste station,swimming pool,walking trails,picnic area,bike repair station,outdoor seating area. Physical Features(waterways, The Kennedy Lateral crosses the northeast corner of the site and the Purdam hazards,flood plain,hillside) Gulch Drain runs along the southwest corner of the site. Neighborhood meeting date 9/21/2022 History(previous approvals) None B. Community Metric Description Details Ada County Highway District No comments received • Staff report(yes/no) No • Requires ACHD No Commission Action es/no Access(Arterial/Collectors/State A collector street(San Marcos Way)is required to be extended from the east H /Local)(Existin and Proposed) boundary to the west boundary of the site per the Master Street Map. Proposed Road Improvements Fire Service • Distance to Fire Station 2.4 miles from Station#2 • Fire Response Time Falls just outside of the 5-minute response time goal • Resource Reliability 82%(above the targeted goal of 80%) • Accessibility This project meets all required access,road widths,and turnarounds as presented in the preliminary plat. The shared drives shall have an address sign at each entrance,the roadways,common driveways,and alleys shall be maintained 365 days a year for fire,EMS,and police responses. • Additional See Fire Staff Report in the link provided below under Section IX(C). Comments/Concerns Police Service • Distance to Fire Station 4 miles from Meridian Police Department • Fire Response Time Expected response time is 4:17 minutes;Average emergency response time is 3:46 minutes for City of Meridian • Accessibility If Applicable,any climate-controlled multi-family developments,the Meridian Police Department required police access into each building's entry point using a multi-technology keypad per UDC 11-4-3-27G. See Meridian Police Department Staff Report in the link provided below under Section IX D . West Ada School District Distance(elem,ms,hs) Capacity of Schools Page 2 #of Students Enrolled West Ada School District has experienced sustained growth in student enrollment during the last ten years.Based on current enrollment data specific to new development(within the last 5 years)in proximity to this proposed development,we estimate this development consisting of 216 apartments and 62 single-family homes could house approximately 79 school aged children.Approval of this application will affect enrollments at the following schools in West Ada School District based on attendance areas for the 2022-23 school year.For your information,included in this data is the number of approved lots and multi-family units approved by this and other agencies. Approved MF units Projected Approved lots per per attendance Students from Enrollment Capacity attendance area area Approved Dev. Chaparral Elementary 498 700 618 2650 170 Meridian Middle School 1057 1250 656 2947 265 Meridian High School 1758 2075 3560 3613 750 School of Choice Options Chief Joseph Elementary—Arts 525 700 N/A N/A Barbara Morgan STEM Academy 416 500 N/A N/A #of students estimated for this 79 development Wastewater • Wastewater Modeling -Additional 9500 gpd committed to model.WRRF decline balance is 14.57 MGD -Sewer and water running in parallel require 30-feet easement •Ensure no permanent structures(trees,bushes,buildings,carports,trash receptacle walls,fences,infiltration trenches,light poles,etc.)are built within the utility easement. •Ensure no sewer services pass through infiltration trenches. • Project Consistent with WW RP Master Plan/Facility Plan • Impacts/Concerns See Public Works Site Specific Conditions Water • Distance to Services • Pressure Zone • Estimated Project Water ERU's • Water Quality Concerns Each Phase will need to be modeled independently to verify adequate pressure. • Project Consistent with Water Yes Master Plan • Impacts/Concerns See Public Works' Site-Specific Conditions Page 3 1 1 milli �M,i�\I "�In11n�11 �♦ �■■■..111111111 IIIIIIIIi���.� \ ��1111■:►■111111111111111111�/II�'- • - • 'I y- /t t_ ■■ ■-;a1 Innnngapol i-nmm� -- 111... 1-, • 11111=_...._. ME all QIIIIIIIII■ r � Q U IIII=� �� • Y F.:ANKLIN"" F •ANKL-IN I �' - __ 1111111► `1i11i�11110111■IIII • IIIIII\Q .Q�1111111-- I\IIIII=-- -OIIIIIl1., �..11111=== 1111111111►; .. . � - III 11111 1 1 ' • 1 1 1 1 11111inn ///11•d� ��: �.■■/� IIII//111•d� ��: �.■■/� ,M�;�� �IIIIIINO .IIl w n tiolii Lf.�Ij�4i:::�iiiiiiiii iin�i����= '• -• '• - iii iiiiiini���- aa�_� •�- ■��i11�1■:►■1111111 IIII' Gil_� 111 11111111111 Gil_' `111��� �` ■■ �a1 Inn11in1 ml iinlnnlG .�a-' n11in1a1n11 iinlnnlG :uun ■-�i 11111=• �_m . X■Ji 3 s� i IIIIIIII ■�..IIIII'=,3=___�;.111111 II- a n_ C-C� ■1'-.IIIm : .1■1111 Illlllllllu11• uu1u111uuuuuul .■■■. IIIII■ i�—��— IIIIIIII�� �. ,ANKLINI•" l mlln►j�nnnnnnl111� l�U �•mlln►�rw.■nungll■mmm� =OIIIIIl1. ♦I�11111 OIIIIIl1. i.O11111=_ �IIIIIIIIII.I-.I�\11111=_ �1111111111. _.. ___=--i ►.IIII- � --__ -i •.IIII_== ■� C. Representative: Laren Bailey, Conger Group—4824 W. Fairview Avenue,Boise,ID 83706 IV. NOTICING Planning&Zoning City Council Posting Date Posting Date Newspaper notification published in newspaper 1/18/2023 3/12/2023 Radius notification mailed to property owners within 500 feet 1/12/2023 3/10/2023 Public hearing notice sign posted 2/17/2023 03/17/2023 on site Nextdoor posting 1/13/2023 3/11/2023 V. COMPREHENSIVE PLAN ANALYSIS (This section and the one below have been updated in a strike-through and underline format that reflects the discussion at the public hearing and the Commission's recommendation on the subject application.) This property is designated Medium High-Density Residential(MHDR)on the Future Land Use Map (FLUM)and is located within the area governed by the Ten Mile Specific Area Plan(TMISAP). LANs USE: MHDR areas are locations recommended primarily for relatively dense multi-family housing types, such as row houses,townhouses, and condominium and apartment buildings and complexes. These areas should have a mix of housing types that achieve an overall average density target of 12 dwelling units per gross acre with densities ranging from 8-15 units per acre. MHDR areas typically are relatively compact areas within a larger neighborhood and generally should be located around and near more intensely developed areas, such as Mixed Use Commercial or Employment areas,in order to provide convenient access to these commercial activity and employment centers for the greatest number of residents.Apartment buildings are desired to be accessed via shared entrances and hallways. The proposed development incorporates a mix of single-family attached homes with(44) front-loaded garages, (18)alley-loaded townhouses and(216)multi-family apartments at an overall gross density of 13.2 units per acre consistent with the density desired in the MHDR FLUM designation in the TMISAP. The apartment buildings have enclosed shared accesses but not shared hallways. This property is in an area that's largely developed with and planned for medium high-density residential uses. Mixed Use—Commercial areas are in the development process approximately '/4 mile to the east and Employment areas are designated approximately'/2 mile to the west and south. The Ten Mile interchange is also within about 1.5 miles to the southeast of the site. TRANSPORTATION: ACHD's Master Street Map(MSM)depicts a new towncenter collector street across this property from the west to the east boundary connecting to N. San Marco Way. The Transportation System Map in the TMISAP lists the functional classification for this street as a collector street and the Street Section Map lists the design classification as a major collector street,which is intended to be constructed consistent with Street Section C as follows: Page 5 1d' 9 B' 6' 1 r l r fi' ' d' �av ne rave ne Bike Lane 24' Lane Cur�-n.cA distance This street is planned to eventually provide a connection from W. Franklin Rd.to the west past N. McDermott Rd.Local streets, an alley and a common driveway are proposed internally for access to the proposed residential units. DESIGN: All residential neighborhoods in the Ten Mile Interchange area should be developed in consideration of Traditional Neighborhood Design(TND)principals and concepts and the standards established by the City for the TN-R district. Future development should be consistent with the design elements in the TMISAP for the MHDR FLUM designation as determined by the Application of the Design Elements table(see pg. 3-49), as follows: (Staffs analysis of consistency with these elements is in italics) 3-33. Street-oriented Design: Useable porches should be a dominant element of residential buildings and should be located along at least 30%of the front fagade of the buildings—a higher percentage is recommended as is the location of porches on one or more side facades. When possible, garages should be loaded from a rear alleyway.Where garages must be accessed from the front,the garages must be located no less than 20' behind the primary fagade. Front-loaded 2-car garages that are visible from the primary street must be designed with two(2) separate garage doors. Out of the 62 single-family attached/townhome units, only 18 are alley-loaded,the other 44 are all front loaded with living area 20'behind the garages away from the street. None of the units have usable porches that meet the guideline, except for the multi family apartments.No porches are proposed on the side facades.All units have single 2-car garage doors, not separate doors. Covered entries to the units are proposed;however, these areas are not usable as a porch as they are barely wider than the doors[i.e. 1'4"wider on the attached units (8"on each side of the door) and 3'wider on the townhouse units(18"on each side of the door)]and are located to the side and rear of the garages—not on the front facade as desired.In order to meet the minimum guideline of 30%,minimum 7.5'wide porches would need to be provided for each attached unit, and 6.6'wide porches would need to be provided for each townhome unit—this would still not provide very "usable"porches as the entryway to the door takes up most of that space. Revisions to i e plans and elevations are neeessary to meet the shwet oriented design ePW14a Uk,*wsufting in wider lots WM a reduedon in the number of units4ots-. Staff reeommends more aHey loaded tojmhomes am provided as an aftetwadw to wider IoAqfor aftoehed units in orwer to meet the design erkeria and if of lose as many lots;A ihffeiwnfpFodWe4"e shoi&4 bepro+idedfo F-ront loaded2 eargarages that atw v&ibleffom thepfimaiystmet must be designed with i4vo(2) separate garage doors-. • 3-34.Buildings to Scale: Everything seen and experienced from the sidewalk—building fronts, lighting,open space—should be designed for human interaction at a pedestrian's perspective.Key elements to consider are the continuity of the building sizes,how the street-level and upper-level Page 6 architectural detailing is treated,elements that anchor and emphasize pedestrian scale,roof forms, rhythm of windows and doors, and general relationship of buildings to public spaces such as streets, plazas and other open space. Human-scale design is critical to the success of built places for pedestrians. Building entrances should be placed close to the street; ground floor windows, articulated facades, appropriately scaled lighting, awnings and other weather protection should be provided. Continuity of building sizes is proposed but with little variation inform and design of any of the structures. The street-level and upper-level architectural detailing offer few differences in the attached and townhome units;architectural detailing between the first two (2)stories on the multi family units are generally the same with a different siding material on the third story. Elements that anchor and emphasize pedestrian scale are windows, doors, weather protection/roofs over windows and doors, window pop-outs and recesses—the addition of masonry accents on the first floor facades would assist in emphasizing pedestrian scale and durability& quality of materials. Building entrances are not placed at the street on attached units as desired, they are located at the rear of the garages away from the street with garages facing the street. Building entrances for the townhomes face the street as desired because these units are alley-loaded. Buildings/living area are not oriented to open space areas or public spaces such as streets(except for the 18 townhome units) as desired. Revisions to the plans and elevations are necessary to meet this design criteria.More architectural variety and details should be provided to differentiate between the street-level and upper-level units.Lighting at a pedestrian-scale should be provided on the buildings facing the street and internal walkways. 3-36.Neighborhood Design: All residential neighborhoods in the Ten Mile interchange area should be developed in consideration of traditional neighborhood design principles and concepts,which pertain to mixed housing stock, architecture and design, streetscapes and streets.Front porches and garages accessed from an alley are usually the standard in residential areas;parking for homes is primarily located behind buildings. Streetscape design relates to the street itself and consists of landscaped parkways with trees between curbs and sidewalks, adjacent sidewalks and front yard spaces and provides public space for street trees, street furniture and view corridors. Other aspects of neighborhood design that contribute to a traditional streetscape are connected network of streets, alleys and sidewalks. Roadways and pedestrian ways are interconnected so that access for pedestrians, cyclists and automobile drivers is direct and convenient and allows traffic to be dispersed through a variety of streets and ways.Narrower streets designed with TND characteristics result in slower moving traffic and provide a safer,more pleasant pedestrian environment and encourages interaction among residents. A diversity of residential housing types is proposed for a variety of housing choices within the same neighborhood as desired.Although two(2) different "types"of architecture are proposed for each of the three(3) housing types, the form is the same and the trim details only vary slightly—only some of the materials and window placements are different—more variety should be provided. As previously noted, usable porches that meet the minimum guidelines are not provided for the single-family attached and townhome units as desired.Alley-accessed garages and parking are only provided for the 18 townhome units;the 44 single-family attached units are all accessed from the street with parking in front of the garages facing the street, which is not desired.Landscaped parkways are proposed as desired with view corridors but no street furniture is proposed except for a couple of benches along the southwest side of the collector street.A connected network of narrow streets, alleys and sidewalks is proposed as desired. ACHD is requiring traffic calming measures to be provided in the collector street to slow traffic. Page 7 tffle should be providedfor the agaehed units jvkh garages set baek of least 201behin provided-.Atom mriety between the buikUwg"es-, niate4als and arehiteeturalfeatimes shou also be proW&d-. • 3-37.Building Form& Character: Building Facades—Buildings should be designed so that their primary facades relate to active public spaces and pedestrian areas. The primary facade of a structure is that frontage of the building that has been designed and detailed so as to represent the building's most important elevations. The primary facade should always include an entry into the building. Entries should be located so as to provide direct access from adjacent public spaces,primary streets and activity areas.Access from walkways should be uninterrupted by vehicular traffic.Buildings should be located so as to help frame adjacent public spaces and to provide an architectural backdrop for associated passive and active activities. The space between a building facade and the adjacent walkway should be appropriately landscaped with a combination of lawns,groundcover, shrubs and trees. The townhomes are designed so that their primary facades face the street with direct pedestrian access from primary streets; access from walkways is uninterrupted by vehicular traffic as garages are accessed from alleys. The single-family attached structures, which make up 71% of the single- family and townhome units, are not designed so that their primary facade relates to active pedestrian areas or public spaces—the garages face the street;the entry is at the living area 20' behind the garages. Building entries do not have direct pedestrian access from the street because garages are in front of the living area facing the street,access from walkways is interrupted by vehicle traffic because all of the units have front-loaded garages and driveways. The multi family units have direct pedestrian access that is uninterrupted by traffic because walkways are proposed up next to the buildings. None of the units, including multi family units,frame open space areas; only the townhome units frame the streets as desired.Landscaping is not depicted on the plan in the space between building facades and adjacent walkways as desired Revisionsto eplans and elevations am neeessary to meet this design e4teri,%A dif-ftientppo tffle should beprovidedfor the aftaehed units jvkh garages set baek as least 20'behin The space between the building fafade and adjacent walkway should be appropriately landscaped with a combination of lawns, groundcover,shrubs and trees;a landscape plan should be submitted that demonstrates compliance with this guideline. Building Heights: Low-rise buildings of 2-4 stories over much of the area is recommended. Two-story single-family attached and townhome structures and 3-story multi family structures are proposed in accord with this guideline. • Pitched Roofs: A mix of flat and pitched roofs are anticipated in the Ten Mile area based on a wide variety of individual buildings. Pitched roofs should be,where possible, symmetrical hips or gables, with a pitch between 4:12 and 12:12 with an overhang of at least 12 inches and a maximum of 2.5'. Roof brackets and rafter tail treatments are encouraged. All of the roof pitches proposed fall within the desired pitch range. Corbels are depicted on all of the concept elevations;rafter tail treatments are encouraged as well as other design elements as noted in the ASM. Page 8 • 3-47.Public Art: Public art should be incorporated into the design of streetscapes,public buildings, parks,transit, infrastructure, and other public projects in the Ten Mile area. Public art should be meaningful and encourage the free flow of ideas and cultural ideologies. Public art should be integrated into either the architectural design or the design of plazas and public spaces associated with a building and should be easily visible to the public (e.g. visible from the street or publicly accessible open spaces rather than interior courtyards). Public art is not proposed but should be provided in accord with this guideline.Details should be submitted prior to the City Council hearing on what type of public art is proposed and the location of such. The provision ofpublic art would also qualify as another amenity(1 point). Goals,Objectives, &Action Items: Staff finds the following Comprehensive Plan policies to be applicable to this application and apply to the proposed use of this property(staff analysis in italics): • "Encourage a variety of housing types that meet the needs, preferences, and financial capabilities of Meridian's present and future residents."(2.01.02D) The proposed single-family attached dwellings, townhouse dwellings and multi family apartments will contribute to the variety of housing types available within the City. • "Permit new development only where it can be adequately served by critical public facilities and urban services at the time of final approval, and in accord with any adopted levels of service for public facilities and services."(3.03.03F) City water and sewer service is available and can be extended by the developer with development in accord with UDC 11-3A-21. • "Avoid the concentration of any one housing type or lot size in any geographical area; provide for diverse housing types throughout the City."(2.01.01 G) This area contains a variety of housing types, including single-family attached and detached homes, townhomes and apartments, which contributes to the diversity in housing types available within the City. • "Require all new development to create a site design compatible with surrounding uses through buffering, screening,transitional densities, and other best site design practices."(3.07.01A) The western portion of the site proposed to develop with single-family attached and townhouse dwellings should be compatible with adjacent like uses to the west and south; the eastern portion of the site proposed to develop with multi family apartments should be compatible with adjacent townhouse and multi family apartments to the east. The railroad tracks and associated right-of-way provides a 200 foot separation between single-family detached homes and the proposed development. The street buffer and associated landscaping along the proposed collector street(N. San Marco Way)will assist in buffering the single-family attached and detached homes and townhomes to the south. The proposed density should be compatible with adjacent existing and future development in the MHDR designated area. • "Encourage compatible uses and site design to minimize conflicts and maximize use of land." (3.07.00) The proposed residential uses and site design should be generally compatible with adjacent residential uses and developments. • "Support infill development that does not negatively impact the abutting, existing development. Infill projects in downtown should develop at higher densities, irrespective of existing development."(2.02.02C) Page 9 The proposed infill development shouldn't negatively impact adjacent existing properties as similar uses and densities exist and/or are planned in this area. • "Ensure development is connected to City of Meridian water and sanitary sewer systems and the extension to and through said developments are constructed in conformance with the City of Meridian Water and Sewer System Master Plans in effect at the time of development."(3.03.03A) The proposed development will connect to City water and sewer systems with development of the subdivision;services are required to be provided to and though this development in accord with current City plans. • "Require pedestrian access in all new development to link subdivisions together and promote neighborhood connectivity."(2.02.01D) There are no multi-use pathways designated on the Pathways Master Plan for this site, nor are any pathways stubbed to this property other than sidewalks along public streets. The sidewalks along streets will promote pedestrian connectivity with adjacent neighborhoods. • "Require urban infrastructure be provided for all new developments, including curb and gutter, sidewalks,water and sewer utilities."(3.03.03G) Urban sewer and water infrastructure and curb, gutter and sidewalks are required to be provided with development of the subdivision. • "Eliminate existing private treatment and septic systems on properties annexed into the City and instead connect users to the City wastewater system; discourage the prolonged use of private treatment septic systems for enclave properties." If annexed, the septic system for the existing home is required to be removed with development. • "Maximize public services by prioritizing infill development of vacant and underdeveloped parcels within the City over parcels on the fringe."(2.02.02) Development of the subject infill parcel will maximize public services. VI. STAFF ANALYSI A. ANEXATION(AZ) The Applicant proposes to annex 23.67 acres of land with a TN-R(Traditional Neighborhood Residential)zoning district which is listed in the Zoning District Compatibility Matrix in the TMISAP as one of the best choices for zoning in the MHDR designation. A preliminary plat and conceptual building elevations were submitted, included in Section VIII, showing how the property is proposed to be subdivided into 63 building lots and 8 common lots for the development of 44 single-family attached dwellings, 18 townhome dwellings &216 apartments for a total of 278 new residential units. The proposed residential use,mix of housing types and density of the development is consistent with the MHDR FLUM designation; however,the proposed architectural design,especially for the attached units,does not comply with the TND guidelines in the TMISAP, as discussed above.Development in this area should conform to these guidelines in order to be deemed consistent with the Plan and in the best interest of the City for annexation. Staff r-eeommends revisions to the plans as noted above in Seetion V prior-to Commission aetion on this appliention. This property,along with two (2) 1-acre properties to the south, are enclaves surrounded by existing and future residential uses—single-family residential detached homes exist to the north(Chesterfield), townhome dwellings are in the development process to the south(Ascent),townhome-style multi-family Page 10 dwellings exists to the east(Entrada Farms), single-family attached and detached homes are in the development process to the south(Alamar); and single-family attached homes are anticipated to develop on the property to the west(Aviator). A legal description and exhibit map for the boundary of the property proposed to be annexed is included in Section VIII.A. This property is within the City's Area of City Impact boundary and within the area governed by the Ten Mile Interchange Specific Area Plan(TMISAP), as discussed above in Section V. The City may require a development agreement(DA) in conjunction with an annexation pursuant to Idaho Code section 67-6511A. If this property is annexed, Staff recommends a DA is required with the provisions discussed herein and included in Section IX.A. B. PRELIMINARY PLAT(PP): A preliminary plat is proposed consisting of 63 [44 single-family attached, 18 townhomes&one(1) multi-family lot for 216 apartment units] building lots and eight(8) [five (5)landscape, one(1) common driveway, one (1)alley and one(1)non-buildable)common lots on 21.06-acres of land in the TN-R district. Proposed lots range in size from 2,090 to 4,257 square feet(s.f.)with an average lot size of 2,790 sf. The subdivision is proposed to develop in two(2)phases as shown on the preliminary plat in Section VIII.B. The single-family residential portion is proposed to develop with the first phase and the multi-family development in the second phase. Single-family attached dwellings,townhome dwellings and multi-family developments are listed as a principal permitted use in the TN-R zoning district per UDC Table 11-2D-2. Multi-family developments are subject to the specific use standards listed in UDC 11-4-3-27;review of the development for consistency with these standards will occur with the Certificate of Zoning Compliance application. Existing Structures/Site Improvements: There is an existing home and several outbuildings on the property that are proposed to be removed with development. Prior to the City Engineer's signature on the final plat,all existing structures that do not conform to the setbacks of the district are required to be removed. Dimensional Standards(UDC Table 11-2D-6): The proposed plat and subsequent development is required to comply with the dimensional standards listed in UDC Table 11-2D-6 for the TN-R zoning district. There is no minimum lot size in the TN-R district; each building site is required to be of sufficient size to meet the minimum setbacks for the district. A minimum of two (2)housing types are provided as required. Access: Access is proposed via the extension of N. San Marco Way, a collector street,at the southeast corner of the subdivision. San Marco Way will extend to the west boundary and connect with W. Aviator St. to be extended with Aviator Subdivision(H-2020-0111). This property and three(3)properties to the south take access from Zimmerman Ln., a private street;two (2)of these properties don't have public street frontage. ACHD is requiring Zimmerman Ln.to be dedicated and improved as a local public street in order to provide a north/south street connection between Franklin Rd. and the collector street,public street frontage for the two parcels to the south, and access to Ascent Subdivision from a local street,which will enable their temporary vehicle access to be converted to emergency and pedestrian access only.The plat should be revised accordingly. Three(3) stub streets(i.e.E. Chair Lift St.,W.Atomic St. and W. Ski Hill St.) exist in Ascent Subdivision that are required to be extended with development as required by ACHD. A street is planned to stub at the south boundary of the subject property from Alamar Subdivision near the southwest corner of this site per the approved preliminary plat(H-2022-0004). The development agreement for Alamar(Inst.#2022-065010) states the final alignment at the north property line shall be Page I I determined at the time of the second final plat submittal to allow the developer flexibility to work with this developer on the alignment. Although the second phase final plat has not yet been submitted,the common lot at the northwest corner of the Alamar development was included in the first phase(FP- 2022-0027)with the southern portion of the north/south street(N. Feather Reed Ave.),which essentially dictates alignment of the street north to the collector street. ACHD is requiring a stub street to be provided from the collector street to the south boundary of the subdivision in alignment with Feather Reed to the south;ACHD is not requiring Wolfsburg to align with that street. Staff is concerned about the proximity of N. Wolfsburg Ave. to Feather Reed and safety of left-turn movements onto the collector from both of those streets. The collector street has a fairly significant curve in this location as well that may hinder sight distance. Common Driveway(UDC 11-6C-3D): One(1) common driveway is proposed at the northwest corner of the site on Lot 10,Block 1 for access to Lots 11-14,Block 1. Common driveways are allowed to serve a maximum of four(4) dwelling units; in no case shall more than three(3) dwelling units be located on one(1) side of the driveway. A total of four(4) dwelling units are proposed on the north side of the driveway; the final plat and common driveway exhibit shall be revised to depict a maximum of three(3)units on one(1) side of the driveway as required; or,alternative compliance may be requested as set forth in UDC 11-5B-5. A perpetual ingress/egress easement is required to be filed with the Ada County Recorder for the common driveway,which shall include a requirement for maintenance of a paved surface capable of supporting fire vehicles and equipment. This may be accomplished through depiction of the easement on the face of the final plat and an accompanying note.If a separate easement is recorded,a copy should be submitted to the Planning Division with the final plat for City Engineer signature. Alleys (UDC 11-6C-3B. : One(1)20-foot wide alley is proposed for access to the townhome lots in Block 3. The Alley should be constructed in accord with the standards listed in UDC 11-6C-3B.5. A detail of the alley should be submitted with the final plat that demonstrates complies with these standards. Parking: All single-family attached and townhouse dwelling units are proposed to have a 2-car garage with a 2-space parking pad consistent with UDC Table 11-3C-6 for 1-to 4-bedroom units; if any units contain more than 4 bedrooms, an additional two (2) spaces are required with at least one(1)of those being an enclosed space. An additional 38 on-street parking spaces(0.5+per home) are available for residents and guests as shown on the parking exhibit in Section VIII.1. These spaces are located adjacent to common areas and in front of the townhome units as there is not adequate room in front of the attached units for on-street parking with the width of the lots vs. the driveways. With the narrow 27-foot wide streets proposed internally,which are desired with TND,parking is only allowed on one side of the street. A minimum of 430 parking spaces are required to be provided for the multi-family development based on 48 1-bedroom units and 168 2-bedroom units,with 216 of those spaces being in a covered carport or garage,per UDC Table 11-3C-6. A total of 442 parking spaces are proposed overall,which exceeds the minimum by 12 spaces,with 221 of those spaces covered. Based on the number of parking spaces provided(442), a minimum of 18 bicycle parking spaces are required per UDC 11-3C-6G, in accord with the standards in UDC 11-3C-5C. A total of 18 spaces are proposed. Staff recommends a bicycle rack is provided for each building and for the clubhouse. Landscaping(UDC 11-3B): A 20-foot wide street buffer with an 8-foot wide parkway planted with Class lI trees and a 5-foot wide detached sidewalk is required to be provided along N. San Marco Way, a collector street,per UDC Table 11-2D-6, landscaped per the updated standards listed in UDC 11-3B-7C. An 8-foot wide parkway with Class 11 trees is required along all local streets per UDC Table 11-2D-6, landscaped per the standards listed in UDC 11-3B-7C. Page 12 All common open space areas are required to be landscaped with one deciduous shade tree for every 5,000 square feet of area and include a variety of trees, shrubs, lawn or other vegetative groundcover per UDC 11-3G-5B.3. Shrubs should be added to common open space areas and the calculations table on the landscape plan should be revised to include this updated standard; a minimum of 28 trees are required. There are several existing trees on this site that will be removed with development. An existing tree inventory and mitigation plan is included in Section VIII.H. Mitigation is required to be provided per the standards listed in UDC 11-3B-10C.5; calculations demonstrating compliance should be included on the landscape plan submitted with the final plat application. Landscaping is required along all pathways per the standards listed in UDC 11-3B-12C. Common Open Space(UDC 11-3G-3): A minimum of 15%qualified open space is required to be provided within the single-family and townhome portion of the development per Table 11-3G-3 for the TN-R zoning district. Based on 10.01 acres of land,a minimum of 1.5 acres is required to be provided that complies with the standards listed in UDC 11-3G-3B.Note: The multi family development is exempt from these standards and is instead required to comply with the common open space standards listed in UDC 11-4-3-27C. The multi family development will be reviewed for compliance with those standards with the Certificate of Zoning Compliance application. The exhibit included in Section VIII.F depicts 35.4%(or 3.55 acres) of common open space for the single-family and townhome portion of the development consisting of three(3) large common areas over 5,000 square feet(s.£)at 41,652 and 9,239 s.f. and a large area at the south end of the site west of the collector; 8-foot wide landscaped parkways along the townhome lots; and landscaped linear open space. The common lot at the southwest corner of the development will adjoin common area in Alamar Subdivision if the stub street to the south is relocated further to the east as required. The collector street buffers do not count toward qualified open space unless they meet the enhanced buffer requirements noted in UDC 11-3G-3B.3,which is interpreted to mean buffer landscape materials consistent with entryway corridors listed in UDC 11-3B-7C.3f. On the south side of the collector,the linear open space that is outside of the buffer may count if landscaped per the standards listed in UDC 11-3B. design.Preferably,the open spaee exhibit should be revised prior-to the Commission hearing but at the latest before the City Couneil hearing,to inelude landseaping and other-design features that demonstrate eomplinnee with the quality and qualified open spaee standards liste Any areas that don't qualify should be depicted as non- qualifying open space.When multi-family is approved concurrently with single-family,the minimum open space requirements in UDC 11-3G-3 shall apply to the gross land area of the entire development. In order to qualify,common areas should be landscaped per the updated standards listed in UDC 11-3G-4B.3; parkways and street buffers should be landscaped per the standards listed in UDC H- 3A-17E and 11-3B-7C[collector buffers must meet the enhanced buffer requirements(i.e. entryway corridor standards)in order to qualify]; stormwater swales that are incorporated into required landscaped areas should comply with the standards listed in UDC 11-3B-11c; and linear open space should be landscaped per the requirements in UDC 11-3B. Site Amenities(UDC 11-3G-4): A minimum of two (2)points of site amenities are required based on the area of the single-family/townhome portion of the development. Qualified amenities should include features listed in UDC Table 11-3G-4. A 5,000+ s.£ children's playground with a play structure, swings, climbing rocks, a climbing dome, seating benches, and a shade structure within a safe fenced area(3 points)is proposed which meets the minimum standard. The provision of public art, as recommended, will also qualifty as an amenity(1 point). The"pathway park" consisting of 9,239 s.f. at the southwest corner of the development where a shade structure,pathway and seating area is Page 13 proposed should include a picnic table in order to qualify as a picnic area(2 points).Required sidewalks adjacent to public right-of-way do not qualify. Overall,the proposed amenities exceed the minimum standards.Note: The multi family development is exempt from these standards and is instead required to comply with the site amenity standards listed in UDC 11-4-3-27D. The multi family development will be reviewed for compliance with those standards with the Certificate of Zoning Compliance application. Pathways: The Pathways Master Plan does not depict a multi-use pathway on this site.No pathways are proposed except for sidewalks required along streets within the development. Sidewalks(11-3A-17): A 5-foot wide detached sidewalk is required along W. Franklin Rd., an arterial street, and along local streets in the TN-R zone within the development; and a 6-foot wide detached sidewalk is required along N. San Marco Way, a collector street per Street Section C in the TMISAP, consistent with the 6-foot wide sidewalk in Entrada Farms to the east. Fencing 11( 3A-D: Fencing should comply with the standards listed in UDC 11-3A-7. Six-foot tall solid vinyl fencing is proposed around the west and north perimeter boundaries of the subdivision and on shared lot lines between building and common lots that are visible from the public street, as shown on the landscape plan. A 5' tall open vision iron fence is proposed around the children's playground area. A 2-rail split rail fence is proposed at the back edge of the street buffer along the northeast side of San Marco Way on the multi-family portion of the site. Fencing is not proposed along the perimeter of Lot 1,Block 4 where it adjoins future common area in Alamar Subdivision and should not be so that residents of both subdivisions can enjoy a larger common area. Lighting(UDC 11-2D-6F1: In addition to the standards set forth in UDC 11-3A-11 of this title,the following standards shall apply within the TN-R district: All dwelling units shall have a minimum of two (2)lights at the front of the unit.All dwelling units on alley accessed properties shall have a minimum of two (2)lights along the alley. All lighting required in this section shall prevent uplighting and shall be on a photocell that activates the lighting at dusk and turns it off at dawn. Waterways: The Kennedy Lateral crosses the northeast corner of this site within a parcel of land owned by the irrigation district. This parcel bisects the subject property into two(2)parcels. The Applicant is working with the irrigation district to try to deed the small"triangle"area on the north side of the lateral to the irrigation district because it is of no value to this development. A 6-foot tall closed vision vinyl fence is proposed adjacent to the lateral; UDC 11-3A-6C.3 requires an open vision fence at least 6-feet in height and having an I I-gauge,2-inch mesh or other construction, equivalent in ability to deter access to the lateral. Staff recommends a 6-foot tall wrought iron fence is provided in this area to deter access to the lateral. Utilities(UDC 11-3A-21): Connection to City water and sewer services is required in accord with UDC 11-3A-21. Street lighting is required to be installed in accord with the City's adopted standards, specifications and ordinances. Pressurized Irrigation System (UDC 11-3A-15): Underground pressurized irrigation water is required to be provided to each lot within the subdivision as set forth in UDC 11-3A-15. Storm Drainage(UDC 11-3A-18):An adequate storm drainage system is required in all developments in accord with the City's adopted standards, specifications and ordinances.Design and construction shall follow best management practice as adopted by the City as set forth in UDC 11-3A-18. A geotechnical report was submitted with this subdivision. Building Elevations: Conceptual building elevations were submitted for the proposed structures within the development as shown in Section V111.1. Two (2) elevations were submitted for the 2-story attached units proposed in Blocks 1 and 2 and for the 2-story townhome units attached in units of three(3) proposed in Block 3;building materials consist of a mix of board&batten siding, soffit board siding, Page 14 cottage lap siding and shake siding. Two(2) elevations and perspectives were submitted for the 3-story multi-family apartment buildings;building materials consist of mix of board&batten siding and horizontal lap siding with fiber cement panel accents.An elevation was submitted for the clubhouse; building materials consist of a mix of board&batten siding and horizontal lap siding with stone veneer accents. The proposed elevations are net approved in concept however,imd they should be revised4o ineor-por-ate traditional neighboFhood design elements as set for-th in the T-AUSAP,as noted above in Section 41 and in to comply with the Architectural Standards Manual(ASM).Remised elevations should be submitted that demonstrate eomplianee with these guidelines and standards prior-to Commission netion on this applivation. Certificate of Zoning Compliance (CZC): A CZC application is required to be submitted for the multi- family portion of the development; compliance with the specific use standards listed in UDC 11-4-3-27 is required. Design Review: A design review application(s) is required to be submitted for all single-family attached, townhouse and multi-family structures within the development.Final design of all structures should comply with the standards for traditional neighborhood design listed in the Architectural Standards Manual(ASM)and any applicable traditional neighborhood design guidelines in the Ten Mile Interchange Specific Area Plan(TMISAP)for the MHDR FLUM designation(see the Application of Design Elements table on pg.3-49).Note: Staff has not reviewed the proposed elevations for consistency with the design standards in the ASM; this review will take place with submittal of the design review application.The Applicant should closely review these standards when making changes to the elevations in order to most accurately represent the style and construction of homes proposed to be constructed on this site. VII. DECISION A. Staff: Staff recommends approval of the proposed annexation with the requirement of a Development Agreement, and preliminary plat per the provisions in Section IX in accord with the Findings in Section X if revisions are made to the plans as recommended by Staff that are consistent with the traditional neighborhood design guidelines in the TMISAP. B. The Meridian Planning&Zoning Commission heard these items on March 2, 2023.At the public hearing,the Commission voted to recommend approval of the subject AZ and PP request. 1. Summary of Commission public hearing: a. In favor: Hethe Clark(Applicant's Representative) b. In opposition:None c. Commenting. None d. Written testimony: None e. Staff presenting application: Bill Parsons f. Other Staff commenting on application:None 2. Key issue(s) public testimony a. None 3. Key issue(s)of discussion by Commission. a. Incorporating more alley-loaded townhome lots in the development. b. Architectural design standards in the TMISAP, specifically as it related to front porches, individual garage doors and stepping the garages back 20 feet from the primary facade. C. Design elements of the Plan versus the TN-R standards in the UDC. d. Extension of Zimmerman Lane. 4. Commission change(s)to Staff recommendation: Page 15 a. Comission modified DA provison i.to specify that the single-family attached and townhome structures did not need to comply with some of the design elements in the TMISAP. b. Various DA proivisons and conditions of approval were modified to account for ACHD's determination for the extension of the surrounding stub streets to this property. The email and the exhibit have been uploaded below under the Agency comments section IX. for reference. 5. Outstandingissue(s)ssue(s) for City Council: a. Removing the 50-foot sliver of property,known as Zimmerman Lane, from the boundary of the annexation and preliminaryplat to allow the applicant time to potentially deed this property to the adjacent County residences to own/maintain. The applicant is proposing the Council add the following DA provison should you choose to support the applicant's request: "Per ACHD direction, Zimmerman Lane will not be dedicated as public right-of-way, with the exception of two stub locations at Atomic St. and Chair Lift St. Dedicate such stub locations to ACHD in configurations required by ACHD prior to signature on the first final plat. The remainder of Zimmerman Lane will remain a private access. Because Zimmerman Lane will remain a private access, modify the annexation and preliminary plat boundaries to remove Zimmerman Lane to facilitate possible future conveyance of the remainder of Zimmerman Lane to property owners benefitted by this access easement who remain outside city limits." Page 16 VIII. EXHIBITS A. Annexation Legal Description and Exhibit Map I 5av tooth Land Surveying, LLG r- P:(200)398-61 pa f:(206)39b-8105 2030 5.Wa5hmgton Ave.,Emmett, ID 536 17 Newkirk Annexation Description BASIS OF BEARING is N. 891115'34"VV., between a found aluminum cap PLS 14221 marking the SIJ4 corner of Section 10 and a found aluminum cap PLS 14221 marking the SW corner of Section 10, both in Township 3 North, Range 1 ~Nest,606se Meridian, City of Meridian,Ada County, Idaho. A parcel of land located in the E112 of the SW1/4 of Section 10,T.3 N., R. 1 W_, B_M_, City of Meridian, Ada County,Idaho more particularly described as follows; COMMENCING at an aluminum cap marking the S1/4 corner of said Section W; Thence N. 89015'34"W-r coinddent with the south line of said SW1}4,a distance of 743.09 feet tip the POINT OF BEGINNING; Thence contlnuing, N.89,,15'34"VV., coincident with said south line,50.00 fleet; Thence N.003426'E., coincident with the west right of way of N.Zimmerman Lane and the extension thereof,903.05 feet to the approximate centerline of the Purdam Drain said point Wine d S-0°34'25"W., 10.00 feet with a 5/8"rebar with cap PL511779; Thence coincident with said centerline the following three(3)courses and distances; Thence N.60°56'14"W.,425.75 feet; Thence S.59404'26"W., 103.00 feet; Thence N.5T29'07"W., 74.36 feet to tfie west line of dhe east half of the SEi/4 of the S 1/4,said point witnessed N.0636'35"E., 69.53 feet with a 518" rebar with cap PLS 12464; Thence N.(r36'35"E.,coincident with said west line,6 14.70 feet to the centerline of the railroad right of way,- Thence S. 88026'46" E.,coincident with said centerline, 1097.69 feet; Thence leaving said centerline, 5, 0135004"W., 216.64 feet to a 5{8"rebar with no cap,hereafter referred to as"Point A"on the soulthwesteriy right of way of the Kennedy Lateral; Thence continuing,S.0°35'04"W., 1250-38 feet to the approximate centerline of said Purdarn Drain, said point witnessed N.0035'04'E.,42,00 feet with a 5/8"rebar with cap PLS 11779; Thence N. 39111540"W., coincident with said centerline,813.62 feet to a paint on the east right of way of said N.Zimmerman Lane,said point witnessed S_ V34'26"W., 20,00 feet with a 5/8"rebar with no cap; P Q0210 1 M121381-NEWKIRK TOPO Survey',Drawings�0escnptions1121381 NewKirk Annexation 1)escnp1ion.dgcx Page 17 Thence S. 01134'26' W., ONncident with said east right of way and the extension thereof,843.25 feet to the POINT OF BEGINNING. LESS and EXCEPTING a parcel of land more particularly described as follows: BEGINNING at the aforementioned "Point A", Thence N. 42057'39"W.,coincident with the southwesterly right of way of said Kennedy Lateral, 25.93 feet to a 5/8'rebar wit# cap PLS 11779; Thence N. 58°29425"W.,corncident with said southwesterly right of way, 133.89 feet to a 5/8" rebar with cap PLS 11779; Thence N. 88°22'37"W.,coincident with said Southwesterly right of way, IM62 feet to a 5/8"' rebar with cap 131-5 11779; Thence W 1012'41" E., coinddent with said southwesterly right of way, 31.04 feet to a 518" rebar with cap PLS 11779 on the southerly railroad right of way; Thence 5. 88°2646"E., coincident with said southerly railroad right of way,232.69 feet to a 5/8"rebar with cap PLS 11779 on the northeasterly right of way of said Kennedy Lateral, Thence S. 58°29'25"E.,coincident with said northeast"right of way, 100.62 feet to a 5/W rebar with cap PLS 11779; Thence S. 01135'04"W., 66.38 feet to the POINT OF BEGINNING. Said parcel contains 23.669 acres more or less. 11574 1 4 ` BEP,1� P:Q02Ik1 t=MTk121381-NEVVKIRK rOPo%surveyzeawings%Desoriptionsti121381 Newkirk Annexation Qescriplion.dotx II Page 18 PRr f f,g,.,, 12NION PAClRIC RAILROAD 'PF V113 Ittii sAr 7277'F r'4 Co � '1�01 , IVA I glow Y .rn m 4 I { I I YI ={ y LQ I Y I ,# PCIAYFOF 6sEGan4mG R. PRAN[{Ll�l ROAD v{ Wa S OF BEARING � x Page 19 B. Preliminary Plat(dated: 10/21/22)—NOT APPROVED PRELI Tovms I NEWK PLAT FOR ---- --- NEWKIRKRK SUBDIVISION -s sE iia u mcsrr iie�sxENa •oa xo W �WQ um3 irp ---r— ----------- .-.,a..� a� boki ®LqRWI —-------------�i V@'iwK".o ? < _.r. Z N'SMFl�1 Imo'.' i i i kILQ% ------------ 1 / j K o — - ------ -- -off--- i ¢ o I_--_— _ --_ —_-- "pp, Page 20 ----------------------------------------------------- f ------ - ---------------------------- - ----- - -- 1-7 ------------ ---------------- ------------ ------------- EM Page 21 C. Common Drive Exhibit—NOT APPROVED BLOCK l I LOT 15 TAKES DIRECT + I I I I I STREET ACCESS- + 3.00' SIDE DRIVEWAY LOCATED ON 10.00' SIDE SETBACK I I EAST SIDE OF LOT. UTILITY EASEMENT II SETBACK TYP�I N I I I II II I I II II a I 11 12 I 13 14 I I 15 16 z0 17 18 I IL Y PKORUE nLN N -- it I I--ga— ----I I Ny 2 O O N� 10 " W SEABURG STREET LOT 9 TAKES DIRECT ——STREET ACCESS. f A a DRIVEWAY LOCATED ON a SOUTH SIDE OF LOT. o_ 9 �. 12' REAR I Y o 1 SETBACK TYP 20.00' FRONT ¢ BLOCK 2 I I SETBACK TYP I s I m I I I rVW,.� ---------� 12 oL e B ITT E IV 15 D 15 30 co BOX e059 NEWKIRK SUBDIVISION eolsE,ioes707 COMMON DRIVEWAY EXHIBIT ( ):!:-.-74 cgrahPh:am @�waY— gneenng-com Page 22 D. Landscape Plan—Preliminary Plat(dated: 9/6/2022) 3 z m A 2m zv Cog r H 1, > I \ I � � 01 ,VI I \ I f j I ill y 3; z t� Page 23 E. Conceptual Site Plan&Landscape Plan for Multi-Family Development 3 z m W a m r z :E a I x II+ to C _ i s > z 'LA v N k I A t a j Ir � I � j I � j I Page 24 NEWKIRK APARTMENTS N,ZIMMERMAN LANE VIEAIOIAN,IDAHO UY€RALL GENERAL SITE Na TUF •'..0 SSALE; .. , ', ...........,1'.SQ_G"..-. ..... ..... _-..- ...,.,... -TE�t •.+�.A i..�w.t.a. TOTAL AREA. .... 451,766 5'F_ _ DENSITY PROPOSED:........7U.7 D.U-ACRE $IDES: ID FRY «. ,p BEAK ID FOP .. +r r' _ FRONT[COLLECTORI: 20 FE41 IT PROJECT DATA; -- NYM6FR DF APARTNEBT ......... I OF OWELUIM UNITS;...............Zll P PAXEIEQ RECUIREU:.......................418 1 5 SPACL-1 149 1 rDRIVI UNITS■72 I 2 PACE&E I FE 2 NORM URLE1=IN M K PARKING SPACES PROPOSED:...............4Ai �R1LYSi�� x J ! PARKING SPACES PROPOSE D PEN 0KI11........Lib GDYERED SPACESIEQUIRED:.......... .....21r rl COVERED SPACES TROPOSED:...............121 _ COMPACT SPACES PROPRS EO ................0 &CCE$SINL9PARKINr5FACE$nGUIREO;.......19 ^+^�* 'f = ACC E$SIBLE PARRINfi SPACES PROPOSED:..,....,1 RICYCL€PARYINC SPACES PROPOSED F x '' n COMMON OPEN SPACE REQUIRED.......Sk4M S.F. . = • I__I ,C-`F.. 162 R.U.125115.F;'D.U.-0.56a S.F. IL"'II "•" 5-D.A.1350S-F.O.U.-1112065.F. y — •_ COMAADY DPENSPACE PROVIDED:.......46.3R21f. SITIEOEVELOPMEMT AMENITIES PROPOSED: I. CLUBHOUSE(QUALITY OF LIFE) * c coo \ HTYEBS CENTER 10DAlITY Of iJFEI ~ \\ S_ E1IGLGSED SIRE STOWE LQUALIFT OF LIFE I 4_ DOG PARK W,-VWLSTE STATION(OQALIFY OF LIFE) 5. POOLIRECREATIOK) s 6- VIALMIN9 TRAILS IRECREATIDN) 1 ' T PICNIC LILEik(OPEN SPACE) L J_ BIKE REPAIR STATION(MUiTI-M40ELI ' 3 V DEVELDPFR; 624,LLC &DI w&UNGCK ST. rwsE,IV 6]792 I CIVIL ENWRLER: CIVIL SITE WORKS .�. WA IV RICRMONE SF. PULSE.In 3]7115 [201)S46-3074 ARCHITECT: T14E ARCHITECTS OFFICE,PLLC 491 MAIN$1. mu E RE mu KOISF,m E T70Y Al 00 •w - (296)SAS•29 1 C,4lka Si•L i:L h Page 25 F. Common Open Space Exhibit&Calculations ]I .I:{ L 4 1 Ij I � I t , Page 26 Project: Newkirk Neighburhaad Date: 11.21.2022 M&& Lot Sgft Open Spare dlnFen3i6nC UesuipLion Cade Section 1 L 4XI 41.31'a M' Cul lu ncir Fruntage C. 1 AI I r9,430 Multi-Fam ily Open Spa" M F 2 S 4,"S 19S'x21.06' End Cap a 2 I8 39.734 Large Park A d L $792 Colecior Frontage{Park A.0 S 95,6&S {pl lector Frontage AC rkSJO Parkway Strip E Subtotals lYaez Percent of Total T431al SgFt 308.927 7.09197SM Qualified Open Space Ar_ 3,09 Total ProjedAcres WAS Mon-Cou2Vvinp Open Spore 0.90 Percent of Clu;zUfiedOpen Space 34-69% Arterial and Collector FronL:rigc 9$729 2.27 31-9G% L3urrcr3&Endcag* 4,49S 4-10 IAA% IlilLside 4A0 4A0% 'Useable' 205,714 4-32 6659% Pace 1 Uwe Sufic:: aesorofim A 11-3S-31A-20 Open grasser area or.A ka%LS,"'in arma- 9 11-M-38-11E linear open spars arm that isat lemA twenty feet(2Oa and rip to RFty feet 150'),hasan access aL mach made and is improwed and landscaped asmeLforth inwhsection E of thcsmdion. C ii-3 31f1-3 fulI Areaof Buffer The Full area of the landsmpe buffer alongcollmclor struts may count Roward Lhe required common opraspme- L1 11AG-36-3 Frrcm age oFBufer:FiFLV percent rso%)or the landscape buffer along arterial strmels may count toward lire required mrnmon opmnspace- Parkways Ak+ryg Colknorand Local Residential SLrmeis:Parkvwarys along local residential E 11-3G-A" slrcetsthaL meet all oFthr rollowing sLandsrds miry count towardthu mrnmon porn spuxe requirement: Page 27 G. Site Amenities Proposed Amenities Sir familyAr-ea; A. Large 1-Acre, Play Park(Block L Lot 1 ) - The Newkirk Neigh turJiood Park will ❑ ;ntd in Lne hollowing rucreatiun iacihLics: • Play Structure + 5wings + Seating Benches + 5hadc Structure ,• .4� + Climb ing Rocks _ + Climb i ng a rime - ' + Large Grass play arcs { + Attfactiue Landscaping + Playground fr.king for safety Imo.'" r r DENG++ jP ffJF Cry" 1 � - 1 . i Page 28 U. Pathways—The Newkirk Neighborhoud will include the Following pedestrian pathways- ■ V Wide Separated Pedestrian Pathway on Bath sides of N-San Mama Way—L770 LF Pedestrian pathwaws within the Newkirk Neighborhood will total cnmr one half mile in length. — h. 5.PekTttY C. Pathway Park lBlodk46 Lot 1)-The Newkirk Neighborhood Park will contain a small pedestrian e A *;, park including- ■ Shade Structure * Additional Pathway • Seating Areas • Attractive Landscaping 5TIFRIX17ME Proposed Amenities Multi-family Arca: A_ Multi-Faro ily Amenities—The 2115-unit Multi-family Chalet's will have the fallowing Amen ities: + Clu b House(Quality of Life) + Fitness Center(Quality of Life) + Enclosed Hike Storage(Quality of Life) + Dog Park W))Naste Station Muality of Life) + Pool(Rcrreatfon) + Wi3lkirgTrails Mcreatiun) + Picnic Arca (Open Space) + Bike Repair Station(Multi-Modal) + Outdoor Seating + Attractive Landscaping Page 29 H. Pedestrian Connectivity Exhibit The N ewkirk NeighborhLmd will include pedestrian pathways as well as infernal sidewalks that will form a very conneded and pedleslrian friendly environrnent for the horneoww+ners and public_ Over a mile of pedestrian pathway will be constructed within the Newkirk Neighborhood_This pathway system will provide a Variety of opportu pities for the residents of the Newki rk Neighborhood to wal k, bike or onnnecl to the$realer Ten Mile I nterchange Area. All internal streets and oolleclor roadways will have separated sidewalks. The map below illuslratus the pedestrian mnneclivity_ r rr r 7 'tJ • s. iFf..L r" ti- - A I I I I Page 30 I. Existing Tree Inventory&Mitigation Plan Newkirk Neighborhood Tree Inventory and Mitigation Plan The following is an inventory of existing trees on the proposed Newkirk Neighborhood property. The trees are in fair to poor condition as they have not been well maintained and most are in various stages of decay and nearly all have structural issues.For this reason,we are proposing to remove all the existing trees and to mitigate for some of the caliper inches of loss. Some of the trees such as the willow do not require mitigation per city code. A map and photos of the trees is provided below as well as a total of caliper inches that should be mitigated for and a calculation of trees to be provided in the new development per the landscape plan. It is calculated that approximately 105"of existing tree caliper should be mitigated for,the project is providing 318 new trees with an average caliper of 2"that equals 636 caliper inches. The new trees planted will far outweigh any trees being removed from the site. r� _- HA 3x Ex1171h4 7 L' 2x �f - {r _ W _ : •' , Page 31 Map of existing trees Tree 1 10"Caliper shade—to be mitigated .f. Tree_ 2 Large Willow with rotted base and many dead limbs. No mitigation proposed l: f, Tree 3 Large walnut tree, 30"—40"caliper,multi-trunk,poor condition, structural issues. —To be mitigated at 50%. Page 32 Tree 4 11" Crab Apple poor to fair condition—to be mitigated v, h Tree 5 13" Shade tree—fair condition—to be mitigated Tree 6 6" Shade tree—to be mitigated � r �Y Page 33 Tree 7 18" Shade tree—fair Condition-to be mitigated ,a Tree 8 7"Pine—fair condition—to be mitigated ,y Calculations from the Newkirk Landscape Plans LANr;�c,--�r AFE �tALCJL T IONB LOCATION 12EWIPZEI7 PP.DVIFEo �TI2EET TREES 54 TREES PARK/COMMON 14200 5P 1 0400 = IS TF-tI 5 83 TREES OPEN 5PACE TOTAL NJMBEIZ OP TREE5: Ib MrM 131 T12EE5 ALL EXISTING TREE5 TO BE REMOVED-5EE NOTE 5. THIS SHEET_ Page 34 PLANT SCHEDULE TREES BOTANICAL I COMMON NAME CONT CAL SIZE CITY REMARKS 0 Amer x Reenanii'Jeffemred'f Autum 91=0 Freeman Maple B&B Z" 10 59 H 35W CLASS II Betda papyiiWa'ClurW 1 Clump Paper Bob B&B 2.5' 13 5WH x 40'W.CLASS 11.dump 0 Gleditria triar nthos inermis'SkpcoW TM+Skyline Haney Lo st B&B Z" 44 45'14%35'W.CLASS II Makts x'SpdW Snow;Spring Snow Crabapple B&B 2' 4 2WH x 2TW.CLASS I Prunus uirginiana'Canada Red';Canada Red Chokecherry B&B 2' 4 40'H x4g'W. CLASS II Prunus x cerasifera'CF0i2.am';CriMOn Pointe Flowering Plum B&B T 24 H 20'-;23'W 5'-0' 0 CLASS II PyFtts raleryana'Chatroaleer';CharrtideeF Pear B&B 2" 30 3W-35'H x 22'W.Class II EVERGREEN TREE BOTANICAL:COMMON NAME CCNT ICAL SIZE I CITY REMARKS Pic-Ea gtaura'Sander s Blue'7 Sanders 9kte White Spruce B&B 5-TH 11 5'-4FN x 2'-3'W Piaea glaura'Penduld;Weeping White Spntce B&B 25'H 20 H 12'40'W 5'-& Picea otndrika'Bruns':Bruns Spntce B&B 5'-T H 4 3g'11-1 x TW } Pinusfleailis'VanderwdFs Pyramid'f VanderwAfs Pyramid Pine B&B ii'-T H 0 20'-25'tat&M'-1T Vdde Page 35 J. Conceptual Building Elevations— OTA -AROV D FAIN I EU Ir"X10'CORBEL TRU WOOD B&B SIDING Wf KU ROOFING 34 YR. ❑5 1'%3'BATTS AT 16'O.C. ASPHALT SHINGLES AJW LP SMARTSIDE I'X12' KD ROOF ING STANDING 1 LI'SMARTSIDE 1f'FASC IA 2 ASCIA Wl 1'XB' SEAM METAL ROO I.J sHADOW BD For illustrative (i.e. color& finishes) purposes only—not 'y proposed for construction Ili - 1 110 TRU woo C] OT WOOD 8' SOFFI760AR ODD IDING LAP SIDING _ � IDING 3 111 1 'X6'CORBEL B KNEE BRACL LI'SMAR I SIDE I"%li"CORNERS ❑2 OR I WINDOW I HIM W.�1"%L' 'ON EUGL HEN ULR I RIN1 LP SMARTSIDE 1'X8'TRIM No. COLOR NAME COLOR No. I DARK BROWN METAL WA I 2 3 4 5 2 SEOATE GREY SWB186 INCHMCOAA4 WARM L BLACK NE S WS 5 ■ ❑ cep s�,o 060122 8 WHITE VINYL WIND FRAME WA oorenloel r. zp�d a r � - DESIGN CRITERRI P V V FRONT ELEVATION 1�b] �O 14P CORBEL OEfAILL `w1 LEFT FI Nita --ppp- � m REAR ELEVATION I o W c Q�I lea lt- 4 RIGHT ELEVATION _ 1.0 Page 36 DESIGN CRITERIA sorvlslox - 1 IK VICINITY MAP /,1 FRONT ELEVA TIO-0 ""' 0 i 2 LEFT ELEVATION 1�, r p DETAIL CORBEL ' ol m 00 00 m -, �jm! � 0 REAR ELEVATION 4 RIGHT ELEVATI N ._. � _1 1.0 SMAH SIUt I"A11"Fn3C;IA KU HOOFINGSTANDIN KO ROOFING 30 YR. 30'TALL TRIANGULAR GABLE LI'SMAH I SIDE I'WCUHNER! Wit"Xb SHAD04:'HU. SLAM METAL ROO PHA LT SHINGLE ENT Wf4'BUILDOUT-BMC DOORi WINDOW IRIMA+1'X2- N LIEGE HLAULK I HIM 6 WOODB&BSIDINGWI 1"%3'BATISAII4'O.C. LI'SKIAH I SIDE H'FASCIA 3 ❑3 PAIN I EO 8'X70'CORBE _ ❑ 3 E] TRU WOOD SHAKL SHINGLE SIDING IRUWUOU L' LN' COI IA4:E SII]ING 8 LP SMARTSIO fl'X0'WU.COL. TRU WOOD SOFFI 'WCORDE 1'%8'TRIM BpN BOARDSIDIN KNEE BRAG No. COLOR NAME COLOR ■ 1 CiAS51C FRENCH GREY SW0077 1 2 3 4 2 FENLAN❑ SW7544 3 SEDATE GREY SW6189 4 MODERNE WHITE SW818B 5 STA' -CHESTNUT SW3524 5 6 7 8 6 DARK BROWN METAL WA NONE 7 CHARCOAL BLACK WA e BLACK VINYL WINO.FRAME WA 2 04.01.22 orraai�xlTr Page 37 ------- - - - - - - �- :� n FRONT ELEVATION Ll va=r 2 LEFT ELEVATION O N w/W ,L a REAR ELEVATION DESIGN CRRERIA mw y Zn— w.. G 4 RIGHT ELEVATION n VICINITY MAP 1A B.PACK-A IJ Q •" \ gym., LOT: X BLOCK: X SUBDMSION ME o a FRONT ELEVATION U va^=ru^ LEFT ELEVATION 2 v =r (!+) fe to I ' m 3 REAR ELEVATION va•=rm DESIGN CRITERIA ® 4 rl RIGHT ELEVATION i76`Td' n VICINITY MAP LO Page 38 O _____ __________________________________________________________________ -__--_ __________________________________ ____'_________-___--_-____ _____=-----_ o _:___________ _-----------____________����� ��i�-_=______-__-_---_-__________:- -.______________________= iu Ili Il ilnnll 1 J a u®lu��unli'll 11'WINEul®u a '------- 111I�o I III�I��I�_11 11611 NO. HE 61�111' j`II"I'��III nlll�llllll - 11 =1�= =IIIII=11=1®- -®1-1�=IIIII-11- o-ii-- vv.. [,--IIIIIIIIIIIIIIIIII II �� IIIIIII�IIIIIIIIIII�IIIIIII_] � III: =1 m� __ _______---______=_______=__=___= ---' -__________-__-______- __=__ _-___________ �; ��®�I-ulll6�u�lllll�u�ll�®�� ------------------------ I �llll��llllll�n 11-n_- =®=11-11-11-fw9- =n1-11-I1-n -�=11-11-=n11-1=1i== Sul- MAN-11-11 _1111 _-_ _____________________________________________I=_=_l_-l1___l-_1 I__�--1I__1_I_1I1_�I__ _ _ __________ I - �___-_-_- --_-______ � ___ ____ 1L lllIlI l����llIlI�ll`l l NE IIIII �I 11 n �I =11 IEF111-11 ----------------- -1i=:1� -I-l-�.a----�11"16"�IIIII•�IP®���������=11-I �1iu�..����IIII it���IIiIIII III�����L�u1°�= __11=in -®1=11=11_i1_I®- HE _■-■_■_ ■ _=11-In-��--®1-11-11=11-Im-��-n_11 = I--= �_•__,__I; r ter__ ya ss- Page 40 p, 1 I n a a� APARTMENTS ❑ ❑ FE Ni - a v—Mxrxu..m� 3REAR EXTERIOR ELEVATION J e ❑ ❑❑ .n....,� i F '❑rF # RIGHFIMERIORELLVA]ION '`C5.1 `�� TM -- _ NEWKIRK — — APARTMENTS FRONT EXTERIOR FLEVATION 6ENERALNETES EXTERIOR RNTSH SCHEDULE _—�~ ❑❑❑ RN nA&---_- ...... s AC5.0 9 �LLFF EXTERIOR ELEVATION 3 ....-.. ezrt_s e��'u.xa Page 42 Ft!' v I I unu I I in r- -j c o GATHEMMG V Irl n 0 I c 0 — co 0 cl I -- --- ILI I ; f I ' I I I I =IC) E5EO I--- x _�_= I YNZ d�10E I I I A I � � w Iw 2CYA 20 rill, cuEsr s-� s Fl F-I Page 43 K. Parking Exhibit SINGLE-FAMILY The Newkirk Neighborhood will meet or exceed all of the requirements of the City of Meridian's Cade for off-street parking.All homes within the neighborhood will have a minimum of a two (2) car garage and a driveway that will accommodate an additional two(2) parking spaces, for a total of four(4)off- street parking spaces. As illustrated below,an additional 38 (aver 0.5 additional per home) on-street parking spaceswill be available for use bythe residence. rd • ! I r � h _rS};�S11i1_- I I . MULTI-FAMILY The Newkirk Apartments meet and exceed all parking requirements of the City of Meridian Code. The code requires 418 parking stalls,we are providing 450 parking stalls. Page 44 IX. CITY/AGENCY COMMENTS & CONDITIONS A. PLANNING DIVISION 1. A Development Agreement(DA)is required as a provision of annexation of this property. Prior to approval of the annexation ordinance,a DA shall be entered into between the City of Meridian,the property owner(s)at the time of annexation ordinance adoption, and the developer. Currently, a fee of$303.00 shall be paid by the Applicant to the Planning Division prior to commencement of the DA. The DA shall be signed by the property owner and returned to the Planning Division within six(6)months of the City Council granting the annexation. The DA shall, at minimum,incorporate the following provisions: a. Future development of this site shall be generally consistent with the preliminary plat,phasing plan,landscape plan, qualified open space,qualified site amenities,and conceptual building elevations included in Section VIII and the provisions contained herein. b. The collector street(N. San Marco Way) shall be constructed in its entirety with the first phase of development and shall be designed consistent with Street Section C(major collector street)in the Ten Mile Interchange Specific Area Plan(see pgs. 3-20, 3-22 and 3-23),unless an alternative cross section is approved by ACHD. c. The small triangle portion of the property located at the northeast corner of the development, north of the Kennedy Lateral, shall be deeded to Nampa-Meridian Irrigation District. d. Public art of a high quality of design shall be provided within the development and incorporated into the design of the streetscape or publicly accessible open space as set forth in the TMISAP (see pg. 3-47). e. A bicycle rack should be provided for each of the multi-family buildings and the clubhouse in accord with the standards listed in UDC 11-3C-5C.A minimum of 18 spaces are required. f. A minimum of 442 off-street parking spaces shall be provided for the multi-family development with a minimum of 221 of those spaces in a covered carport or garage as proposed, in accord with UDC Table 11-3C-6. g. A maximum of 216 multi-family units shall be constructed within this development. h. A Certificate of Zoning Compliance application shall be submitted for the multi-family portion of the development; compliance with the specific use standards listed in UDC 11-4-3-27 is required. i. A Design Review application shall be submitted for all single-family attached,townhouse and multi-family structures within the development. Compliance with the design standards listed in the Architectural Standards Manual and the any applicable guidelines in the Ten Mile Interchange Specific Area Plan(TMISAP) is required. The single-family attached and towhome structures are not required to incorproarte porches along 30%of the front facades and front- loaded 2-car .garages do not have to be 20 feet behind the primary fagade or designed with two (2) separate garage doors. The r-esidefAial deve ,,..me fft shall be developed; sider- do f NIHDR Futefe Land Use Map designation(see the Appliea4ien of the Design Elemeffts table e j. Pedestrian-scale lighting should be provided on all building facades facing the street and internal walkways in accord with the TMISAP(pg. 3-34). Page 45 k. The space between the building fagade and adjacent walkway should be appropriately landscaped with a combination of lawns,groundcover, shrubs and trees in accord with the TMISAP (pg. 3-37). 2. The final plat shall include the following revisions: a. . AG14D. b. Extend the three(3) stub streets(i.e. E. Chair Lift St.,W. Atomic St. and W. Ski Hill St.) from Ascent Subdivision into the site as required by ACHD. c. Align San Marco Way with the approved location of the stub street at the west boundary of the site from Aviator Subdivision. d. Extend right-of-way to the south from San Marco Way in alignment with Feather Reed Ave. in the future second phase of Alamar Subdivision. The stub street will need to be located on the east side of the common lot(Lot 3, Block 1) at the northwest corner of Alamar subdivision as approved with the first phase final plat. e. Depict a maximum of three(3)units on one(1)side of the common driveway on Lot 10, Block 1 in accord with UDC 11-6C-3D.1; or,obtain approval of alternative compliance for the proposed design as set forth in UDC 11-5B-5. f. Depict a 20-foot wide street buffer in a common lot or on a permanent dedicated buffer easement with an 8-foot wide parkway and a 6-foot wide detached sidewalk along N. San Marco Way,a collector street,per UDC Table 11-2D-6 and Street Section C in the TMISAP,unless an alternative cross section is approved by ACHD. a lnvOWe lravelLane I Bike Lane ane 34' Curam-uubdislance 3. The landscape plan submitted with the final plat shall include the following revisions: a. Revise the landscape plan consistent with the changes to the final plat listed above. b. Include mitigation calculations on the plan for existing trees that are proposed to be removed in accord with the standards listed in UDC 11-3B-1OC.5 and the exhibit in Section VIII.H. c. Depict landscaping within the 20-foot wide street buffer along San Marco Way in accord with the updated standards listed in UDC 11-3B-7C.An 8-foot wide parkway is required along the collector street planted with Class II trees and a 5-foot wide detached sidewalk per UDC Table 11-2D-6. Include the linear feet of buffer with the number of required vs.provided trees in the Landscape Calculations table that demonstrates compliance with UDC standards. d. Depict an 8-foot wide parkway with Class 11 trees along all local streets per UDC Table I1-2D- 6 landscaped per the standards listed in UDC 11-3B-7C. Include the linear feet of parkways Page 46 with the number of required vs.provided trees in the Landscape Calculations table that demonstrates compliance with UDC standards. e. Depict shrubs in common open space areas in accord with UDC 11-3G-5B.3. f. Update the Landscape Calculations table for common open space areas to reflect the updated requirement of one tree per 5,000 square feet common open space per UDC 11-3G-5B.3; a minimum of 28 trees are required. g. Change the fencing type along the Kennedy Lateral to 6-foot tall wrought iron in accord with UDC 11-3A-6C.3. h. Include a picnic table in the common area at the southwest corner of the site on Lot 1,Block 4. i. Fencing shall not be provided along the perimeter of Lot 1,Block 4 where it adjoins future common area in Alamar Subdivision. j. A minimum of one(1)bench should be provided along the northeast side of the collector street in accord with traditional neighborhood development guidelines in the TMISAP. 4. The proposed plat and subsequent development is required to comply with the dimensional standards listed in UDC Table 11-2D-6 for the TN-R zoning district. 5. The common driveway shall be designed and constructed per the standards listed in UDC 11-6C-3D. Revise the common driveway exhibit in Section VIII.0 to reflect a maximum of three(3) dwelling units on one(1) side of the driveway as set forth in UDC 11-6C-3D.1; or, alternative compliance may be requested as set forth in UDC 11-5B-5. 6. A perpetual ingress/egress easement shall be filed with the Ada County Recorder for the common driveway,which shall include a requirement for maintenance of a paved surface capable of supporting fire vehicles and equipment. This may be accomplished through depiction of the easement on the face of the final plat and an accompanying note. If a separate easement is recorded, a copy shall be submitted to the Planning Division with the final plat for City Engineer signature. 7. The alley shall be designed and constructed per the standards listed in UDC 11-6C-3B.S. A detail of the alley shall be submitted with the final plat that demonstrates complies with these standards. 8. Per UDC 11-2D-6F,all dwelling units shall have a minimum of two (2)lights at the front of the unit. All dwelling units on alley accessed properties shall have a minimum of two(2) lights along the alley. All lighting shall prevent uplighting and shall be on a photocell that activates the lighting at dusk and turns it off at dawn. 9. Prior to the City Engineer's signature on the final plat,all existing structures that do not conform to the setbacks of the district shall be removed. 10. Approval of a preliminary plat shall become null and void if the applicant fails to obtain the city engineer's signature on the final plat within two(2)years of the approval of the preliminary plat. Upon written request and filing by the applicant prior to the termination of the period in accord with subsections(A)and(B)of UDC 11-6B-7,the director may authorize a single extension of time to obtain the city engineer's signature on the final plat not to exceed two(2)years. Additional time extensions up to two(2)years as determined and approved by the City Council may be granted. With all extensions,the director or City Council may require the preliminary plat, combined preliminary and final plat or short plat to comply with the current provisions of this title. Page 47 B. PUBLIC WORKS 1. Site Specific Conditions of Approval 1.1 Sewer and water running in parallel require 30ft easement. 1.2 Ensure no permanent structures(trees,bushes,buildings,carports,trash receptacle walls, fences, infiltration trenches, light poles, etc.)are built within the utility easement. 1.3 Ensure no sewer services pass through infiltration trenches. 1.4 Provide 20'easement and install main to make connection of water line between east and west property. If main in western property is not installed at time of construction install a blow-off per City requirements. 1.5 Do not have a connection to the west. It is a different pressure zone. 1.6 Development to the south shows road in a different location. Coordinate with southern property on location and make sure water main is in road wherever that ends up being. 1.7 Water line requires 20'easement with water line centered in it.No car ports allowed in easement. 1.8 20'Easement up to water meter and 10'beyond is required but cannot go under car ports.Keep that in mind for all areas where it is applicable. 1.9 Water and sewer line require 30'easement minimum. Water and sewer to be 10'from edge with at least 10' separation.No car ports allowed in easement. 1.10 Each phase will need to be modeled independently to verify adequate pressure. 1.11 Connect to existing water stub to the east. Required to provide better looping on the eastern property. 2. General Conditions of Approval 2.1 Applicant shall coordinate water and sewer main size and routing with the Public Works Department, and execute standard forms of easements for any mains that are required to provide service outside of a public right-of-way. Minimum cover over sewer mains is three feet,if cover from top of pipe to sub-grade is less than three feet than alternate materials shall be used in conformance of City of Meridian Public Works Departments Standard Specifications. 2.2 Per Meridian City Code(MCC),the applicant shall be responsible to install sewer and water mains to and through this development. Applicant may be eligible for a reimbursement agreement for infrastructure enhancement per MCC 8-6-5. 2.3 The applicant shall provide easement(s)for all public water/sewer mains outside of public right of way(include all water services and hydrants). The easement widths shall be 20-feet wide for a single utility,or 30-feet wide for two. The easements shall not be dedicated via the plat,but rather dedicated outside the plat process using the City of Meridian's standard forms. The easement shall be graphically depicted on the plat for reference purposes. Submit an executed easement(on the form available from Public Works),a legal description prepared by an Idaho Licensed Professional Land Surveyor,which must include the area of the easement(marked EXHIBIT A) and an 81/2"x 11"map with bearings and distances(marked EXHIBIT B) for review. Both exhibits must be sealed, signed and dated by a Professional Land Surveyor. DO NOT RECORD. Add a note to the plat referencing this document. All easements must be submitted,reviewed, and approved prior to development plan approval. 2.4 The City of Meridian requires that pressurized irrigation systems be supplied by a year-round source of water(MCC 9-1-28.C). The applicant should be required to use any existing surface or Page 48 well water for the primary source. If a surface or well source is not available, a single-point connection to the culinary water system shall be required. If a single-point connection is utilized, the developer will be responsible for the payment of assessments for the common areas prior to prior to receiving development plan approval. 2.5 All existing structures that are required to be removed shall be prior to signature on the final plat by the City Engineer. Any structures that are allowed to remain shall be subject to evaluation and possible reassignment of street addressing to be in compliance with MCC. 2.6 All irrigation ditches,canals, laterals, or drains, exclusive of natural waterways,intersecting, crossing or laying adjacent and contiguous to the area being subdivided shall be addressed per UDC 11-3A-6. In performing such work,the applicant shall comply with Idaho Code 42-1207 and any other applicable law or regulation. 2.7 Any wells that will not continue to be used must be properly abandoned according to Idaho Well Construction Standards Rules administered by the Idaho Department of Water Resources. The Developer's Engineer shall provide a statement addressing whether there are any existing wells in the development, and if so,how they will continue to be used, or provide record of their abandonment. 2.8 Any existing septic systems within this project shall be removed from service per City Ordinance Section 9-1-4 and 9 4 8. Contact Central District Health for abandonment procedures and inspections(208)375-5211. 2.9 Street signs are to be in place, sanitary sewer and water system shall be approved and activated, road base approved by the Ada County Highway District and the Final Plat for this subdivision shall be recorded,prior to applying for building permits. 2.10 A letter of credit or cash surety in the amount of 110%will be required for all uncompleted fencing,landscaping, amenities, etc.,prior to signature on the final plat. 2.11 All improvements related to public life, safety and health shall be completed prior to occupancy of the structures.Where approved by the City Engineer, an owner may post a performance surety for such improvements in order to obtain City Engineer signature on the final plat as set forth in UDC 11-5C-3B. 2.12 Applicant shall be required to pay Public Works development plan review, and construction inspection fees, as determined during the plan review process,prior to the issuance of a plan approval letter. 2.13 It shall be the responsibility of the applicant to ensure that all development features comply with the Americans with Disabilities Act and the Fair Housing Act. 2.14 Applicant shall be responsible for application and compliance with any Section 404 Permitting that may be required by the Army Corps of Engineers. 2.15 Developer shall coordinate mailbox locations with the Meridian Post Office. 2.16 Compaction test results shall be submitted to the Meridian Building Department for all building pads receiving engineered backfill,where footing would sit atop fill material. 2.17 The design engineer shall be required to certify that the street centerline elevations are set a minimum of 3-feet above the highest established peak groundwater elevation. This is to ensure that the bottom elevation of the crawl spaces of homes is at least 1-foot above. 2.18 The applicants design engineer shall be responsible for inspection of all irrigation and/or drainage facility within this project that do not fall under the jurisdiction of an irrigation district or ACHD. The design engineer shall provide certification that the facilities have been installed Page 49 in accordance with the approved design plans. This certification will be required before a certificate of occupancy is issued for any structures within the project. 2.19 At the completion of the project,the applicant shall be responsible to submit record drawings per the City of Meridian AutoCAD standards. These record drawings must be received and approved prior to the issuance of a certification of occupancy for any structures within the project. 2.20 A street light plan will need to be included in the civil construction plans. Street light plan requirements are listed in section 6-5 of the Improvement Standards for Street Lighting. A copy of the standards can be found at http://www.meridiancity.org/public—works.aspx?id=272. 2.21 The City of Meridian requires that the owner post to the City a performance surety in the amount of 125%of the total construction cost for all incomplete sewer,water and reuse infrastructure prior to final plat signature. This surety will be verified by a line item cost estimate provided by the owner to the City. The surety can be posted in the form of an irrevocable letter of credit,cash deposit or bond.Applicant must file an application for surety,which can be found on the Community Development Department website. Please contact Land Development Service for more information at 887-2211. 2.22 The City of Meridian requires that the owner post to the City a warranty surety in the amount of 20%of the total construction cost for all completed sewer,water and reuse infrastructure for duration of two years. This surety will be verified by a line item cost estimate provided by the owner to the City. The surety can be posted in the form of an irrevocable letter of credit, cash deposit or bond.Applicant must file an application for surety,which can be found on the Community Development Department website. Please contact Land Development Service for more information at 887-2211. C. FIRE DEPARTMENT https:llweblink.meridianciV.oLglWebLinkIDocView.aspx?id=286169&dbid=0&repo=MeridianCitX D. POLICE DEPARTMENT https:llweblink.meridianciV.orglWebLinkIDocView.aspx?id=286172&dbid=0&repo=MeridianCitX E. PARK'S DEPARTMENT No comments were submitted. F. NAMPA&MERIDIAN IRRIGATION DISTRICT(NMID) https:llweblink.meridianciU.org/WebLink/DocView.aspx?id=287222&dbid=0&r0o=MeridianQ G. IDAHO TRANSPORTATION DEPARTMENT(ITD) https:llweblink.meridiancily.or lWebLinkIDocView.aspx?id=287028&dbid=0&repo=MeridianCitX H. WEST ADA SCHOOL DISTRICT(WASD) https:llweblink.meridiancily.org/WebLink/Doc View.aspx?id=287286&dbid=0&r0o=MeridianCitX I. ADA COUNTY HIGHWAY DISTRICT(ACHD)—DRAFT REPORT https:llweblink.meridianciU.ofglWebLinkIDocView.aspx?id=289313&dbid=0&repo=MeridianCitX Page 50 EMAIL FROM CHRISTY LITTLE ON THE FURTURE ROAD EXTENSIONS FOR NEWKIRK SUBDIVISON Rill&scnya, Sol iy for tie late e-mail butwe have been workingthrough solutions this week regarding Zimmerman Lane. I had hoped to have a revised reportforyou today,but rather than chance sending a report vrit-,errcrs,I'll j.ist outline the c anges here. 1. Zimr-�--niar_ane_11 rc:::e required to be constructed as a public streetthrough the site. As demonstrated by the TIS,it is not needed to serve the site;and there is no designation on the P✓:'v1 a:tYs lo_a:icr-c"a col ector. 2. Zimmemian La-ie will i emai-i as private and continue to provide aocesstothe parcels that are served today. 3. The developer will be required to ensure that local traffic does not use Zimmerman Lane(i.e.signage,barricades,etc...) 4. Developer will dedicate right-of-way for the future extensions of Atomic St and Chair Lift St;and will be required to provide a road trust for the construction which will be done by a different developer. 5. Ceve'Dcer vil'extend Ski Hill Street nto tie site and Feathp-Reed. 6. ASLEI-t Ave—.us:a renii,ider al:cut:he cc,idit;cn cri Ascent Ave at Franklin Road. That connection was approved as a driveway,and is a temporary right-of-way easement.The plat note states that when other access is available to the site,the driveway will be closed. ACHD will work with that developer when stub streets have been extended. Thanks, Christy � SITE ,IN _ ,1r_"_ U STREETS 1(,'. aPrfK1Y®SiYYa�[r •1ex•r•o -':' �� J. SCHOOL IMPACT TABLE(COMMUNITY DEVELOPMENT) https:llweblink.meridianciU.org/WebLink/DocView.aspx?id=286766&dbid=0&r0o=MeridianCitX K. DEPARTMENT OF ENVIRONMENT QUALITY(DEQ) https:llweblink.meridianciU.or /WebLink/DocView.aspx?id=287890&dbid=0&repo=MeridianCitX L. COMMUNITY PLANNING ASSOCIATION OF SOUTHWEST IDAHO(COMPASS) https:llweblink.meridiancily.or- /WebLink/Doc View.aspx?id=287353&dbid=0&repo=MeridianCitX X. FINDINGS A. Annexation and/or Rezone(UDC 11-5B-3E) Required Findings: Upon recommendation from the commission,the council shall make a full investigation and shall,at the public hearing,review the application. In order to grant an annexation and/or rezone,the council shall make the following findings: Page 51 1. The map amendment complies with the applicable provisions of the comprehensive plan; The Commission finds the Applicant's request to annex the subject property with TN-R zoning and develop a mix of single family attached and townhouse dwellings and multi family apartments on the site at a gross density of 13.2 units per acre is consistent with the land uses and density desired in MHDR designated areas in the TMISAP. 2. The map amendment complies with the regulations outlined for the proposed district, specifically the purpose statement; The Commission finds the proposed map amendment to TN-R and development generally complies with the purpose statement of the Traditional Neighborhood Residential District in that it will provide for a variety of residential land uses, including attached single-family residential, townhomes and multi family apartments; open space that promotes pedestrian activity;safe and efficient movement of vehicular traffic; with some of the units accessed from an alley. 3. The map amendment shall not be materially detrimental to the public health, safety, and welfare; The Commission finds the proposed map amendment should not be detrimental to the public health, safety and welfare as the proposed residential uses should be compatible with adjacent single-family residential homes/uses in the area. 4. The map amendment shall not result in an adverse impact upon the delivery of services by any political subdivision providing public services within the city including,but not limited to, school districts; and The Commission finds City services are available to be provided to this development. WASD has provided comments on the application that are included above in Section IX.H. 5. The annexation(as applicable)is in the best interest of city. The Commission finds the proposed annexation is in the best interest of the city. B. Preliminary Plat(UDC 11-6B-6) In consideration of a preliminary plat,combined preliminary and final plat, or short plat,the decision- making body shall make the following findings: (Ord. 05-1170, 8-30-2005, eff. 9-15-2005) 1. The plat is in conformance with the comprehensive plan and is consistent with this unified development code; (Ord. 08-1372, 7-8-2008, eff. 7-8-2008) The Commission finds the proposed plat is generally in conformance with the UDC and the Comprehensive Plan. 2. Public services are available or can be made available and are adequate to accommodate the proposed development; The Commission finds public services can be made available to the subject property and will be adequate to accommodate the proposed development. 3. The plat is in conformance with scheduled public improvements in accord with the city's capital improvement program; The Commission finds the plat is in conformance with scheduled public improvements for this area in accord with the City's CIP. 4. There is public financial capability of supporting services for the proposed development; Staff finds there is public financial capability of supporting services for the proposed development. Page 52 5. The development will not be detrimental to the public health, safety or general welfare; and The Commission finds the proposed development will not be detrimental to the public health, safety or general welfare. 6. The development preserves significant natural, scenic or historic features. (Ord. 05-1170, 8-30-2005, eff. 9-15-2005) The Commission is unaware of any significant natural, scenic or historic features that need to be preserved with this development. Page 53