CC - Setback Diagram 3-21-23SAGARRA / RESIDENTIAL 03.18.2022
DATE:PAGE TITLE:PROJECT TITLE:01PLANNED UNIT DEVELOPMENTMERIDIAN, IDSCALE: 1" = 60'-0"SETBACK DIAGRAM & INFORMATIONDevelopment Setback Diagram
FRONT GARAGE SIDE STREET SIDE REAR
SETBACK INFORMATION (R-8/PUD REQUEST)
DIAGRAM COLOR UNIT TYPE PROPOSED PROPOSED PROPOSED PROPOSED PROPOSED NOTES:
PHASE I PHASE II
RIBBON TOWNHOMES 0' MIN 0' MIN 5'10'0' MIN 0' IS TO BACK OF COMMON LOT WHICH IS 20' FROM BACK OF CURB
TWO PACK TOWNHOMES 10'0' MIN 5'0' MIN 0' MIN STREET SIDE SETBACK FROM PARALLEL PORTIN OF STREET IS TYPICALLY >10'
MIDDLE THREE TOWNHOMES 8'6"4' MIN N/A 10' MIN 4' MIN
BOULDER FLATS*5' MIN N/A 5' MIN 5' MIN 5' MIN
COURTYARD/HEADWATER CONDOS*2'N/A 5'7'10'THERE ARE 5 GARAGE SPACES AT THE HEADWATER CONDO LOCATION W/ 5' SETBACK
SINGLE FAMILY UNITS 10'20'5'10'10'
NOTE:SETBACKS LISTED ABOVE ARE DEVIATIONS FROM THE MCC R-8 DIMENSIONAL STANDARDS. DIMENSIONS LISTED AS MIN ARE TO
ARTICULATE THAT THOUGH THIS IS LISTED AS THE MINIMUM THE TYPICAL DIMENSION WILL BE GREATER THAN THIS
*THE BOULDER FLATS, HEADWATER & COURTYARD CONDOS ARE MULTI-FAMILY UNITS BEING REQUESTED UNDER THE PUD APPLICATION
CONTROL POINT - PORTION OF BUILDING CLOSEST TO PROPERTY LINE