Loading...
PZ - Landscape plan 1 2 3 4 5 6 7 8 9 10 = GI STACK ROCK (a R 0 M IF) LANDSCAPE ARCHITECTURE & MASTER PLANNING (208) 345-0500 404 S 8th St.#154 Boise, ID 83702 � StackRockGroup.com WILLET C HOWARD, PLA OFFICE: (208)345.0500 EMAIL: WILL@STACKROCKGROUP.COM www.STACKROCKGROUP.COM � I I THE GRAPHICS AND DESIGNS ON THIS SHEET ARE DELIVERABLES THAT REMAIN I \ AT ALL TIMES PROPERTY OF II I \ STACK ROCK GROUP, INC. EXISTING FENCE TO REMAIN, PERSERVE&PROTECT i I i \ REPRODUCTION OR REUSE OF \ � THIS PRODUCT CONTAINED HERE IN IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF STACK ROCK G R O U P I N C LOT 2 I I I GI " ©2022 STACK 26488 SQ. FT. ± I I I I GI \ ROCK GROUP, INC. I I I I I I I II LL I I I I �'I I Seals PRELIMINARY LOT 3 O F �o II 20070 SQ. F I , BERM, 3:1 MAX EXISTING TREES TO REMAIN WHERE POSSIBLE, I i PRESERVE& PROTECT ANY TREES DAMAGED/DESTROYED/REMOVED DURING CONSTRUCTION SHALL BE I I I 6'CLOSED VISION FENCE I I I I GRAVEL W REPLACE D/MITIGTATED ON A 1:1 RATIO I I I I I I I SHOULDER AN ARBORIST REPORT IS RECOMMENDED TO I S� LA-16733 EVALUATE WHICH TREES NEED MITIGATED I I I I I , I• I I O .22.22 P� BOULDER WALL BACKSIDE OF BERM 104 w 0 4gNDSCAPE 3' MAX HEIGHT I i GRAVEL Q I / I I I `102 /.% a° IN SWALE 0 NOT FOR CONSTRUCTION II -100— ° Q LAWN / I w W w W I W s W 2 Z d OMM N DR VEWti PROTECT IW W 1 �0 0 / EXISTING I W y Z U) g ssa � I � .�, � W HOUSE ° w � � z Q W Q Q — - - — — — — --� a - - — �E — W� W � ICI ■(i '• I J W W ° I I � •y ° o PLANT SCHEDULE z I W W TREES BOTANICAL/COMMON NAME CONT CAL SIZE QTY REMARKS `° NO BERM WHERE EXISTING i W I $ Q0 Tilia cordata Greenspire 35'H x 25'W, TREES CALLED TO BE/Greenspire Littleleaf Linden B &B 3" 2 Class II I PRESERVED CD LE / i W EVERGREEN TREE BOTANICAL/COMMON NAME CONT CAL SIZE QTY REMARKS V) (0 IF TREES NEED TO BE REMOVED,OR ARE DAMAGED/DESTORYED I I y ED DURING CONSTRUCTION 0 Picea pungens'Layered' /Layered Colorado Blue Spruce B &B T MITIGATION OF TREES 6 50'H x 20'W � / I . a'I REQUIRED, PER ARBORIST �a a"ss \\ ss i i O SHRUBS BOTANICAL/COMMON NAME CONT FIELD2 SIZE QTY REMARKS RECOMMENDATIONSL 0 T 1 /771% Calamagrostis x acutiflora Karl Foerster' /Feather Reed Grass 2 gal 5 30"H x 3'W 17497 SQ. FT. ± O N / I i GRAVEL W U I LAW IN SWI LE Q Z I � Q Hydrangea paniculata 'Limelight' TM/Limelight Hydrangea 5 gal 10 4'H x 6'W I I 0 U LU ' O w W Juniperus horizontalis'Wiltonii' /Blue Rug Juniper 2 gal g g"H x g'W >- z L T 4 GRAVEL Pennisetum alopecuroides'Hameln' /Hameln Dwarf Fountain Grass 2 gal 20 30"H x 30"W C _ i �. SHOULDER 17363 SQ. I REVISIONS v Physocarpus opulifolius'Diablo' /Diablo Ninebark 5 gal 16 6'H x 8'W MIRK DATE Description® J la° W W Aco ** ** Rhus trilobata'Gro Low /Grow Low Sumac 2 gal 12 30"H x 8'W I I I � .• a — — - - — — — — — — - - Rhus typhina'Lacinata'/Cutleaf Staghorn Sumac 5 gal 7 g'H x g'W — — - - — — — — — — — — — — — — — — — — — — — - — I t z I I , 0 � w F-:.XISTING :_r NIPS :kPINi_Tl, ci= r-•F-' ERVIF & PR 'rECT Q � JOB NO: 22-2922 "'t_Lr)r.ii TE.D 1 [-�c PF�.l r'.�oj`' I�i t:c��`'_ r'keF TO.?i`Y i:�L�wS?i?i.l'�i I�i�' I U S DATE: 03.07.2022 DRAWN BY: JB (� I CHECKED BY: JB N BID s DRAWING TITLE a 3 "GI EXISTING LANDSCAPING&PATHWAY TO REMAIN, PERSERVE&PROTECT LANDSCAPE RELOCATED/REPAIR AS NEEDED DUE TO ANY CONSTRUCTION 36"GI PLAN -36"GI H 36"GI- W W_ LU W (Y H SHEET NUMBER U 0 20 40 60 feet W D R 0 Ll00 00 NORTH SCALE: 1" = 20' 00 r o Y 0 Q H U) 1 2 3 4 5 6 7 8 9 10 1 2 3 41 5 6 7 8 9 10 NOTE: BACKFILL SHALL BE 100%TOPSOIL. NOTES: REMOVE ALL TAGS, TWINE OR WATER SETTLE ALL PLANTINGS TO 1. DO NOT DAMAGE OR CUT LEADER OTHER NON BIODEGRADABLE ENSURE PLANT ROOTBALL 2. DO NOT DISTURB ROOT OR DAMAGE ROOT BALL WHEN INSTALLING TREE OR TREE STAKES. MATERIALS ATTACHED TO PLANT OR MAINTAINS 2" HEIGHT ABOVE 3. TREE STAKING SHALL BE AT THE DISCRETION OF CONTRACTOR. HOWEVER ANY TREES DISTURBED ROOT MASS. EXISTING SOILS WHEN COMPLETE. FROM PLUMB DURING THE PLANT WARRANTEE PERIOD WILL BE REPAIRED OR REPLACED AT CONTRACTOR'S EXPENSE. O 4. WATER PLANTS THOROUGHLY IMMEDIATELY AFTER INSTILLATION. STACK = 5. REMOVE ALL BURLAP, TWINE, ROPE, OR MATERIAL FROM THE TOP 3 OF THE ROOTBALL. 0 po 6. 5' DIAMETER PLANTER BED/MULCH RING AROUND THE TRUNK OF THE TREE. 3"OF MULCH MIN. DO NOT PLACE MULCH WITHIN 2"OF TRUNK OF TREE. I LANDSCAPE ARCHITECTURE & MASTER PLANNING I (208) 345-0500 MULCH 2" MIN. 404 S 8th St.#154 TOP TWO STRUCTURAL AWAY FROM TRUNK83702 ROOTS: <3"BELOW TOP GRAFT VISIBLE ABOVE SOIL OF PLANT. Boise, ID oup. OF ROOTBALL. FOLD BURLAP FROM TOP � StackRockGroup.com LINE OF ROOT BALL DOWN 3" DEEP MULCH MIN. LOWEST STRUCTURAL BALL FINISH GRADE INTO GROUND; SET TOP LAWN OR PAVING WILL@ ROOT BA WILLET C HOWARD, PLA SOIL LINE OF THE TOP OF OF BALL FLUSH WITH OFFICE: (208)345.0500 EMAIL: ROOT BELOW TOP OF THE ROOT BALL AFTER STACKROCKGROUP.COM REMOVING EXCESS SOIL. Www.sTACKRocKGRouP.coM 2,2' 2-3" OF MULCH BACKFILL MIX SEE NOTES AND 12"TO 18" FOR SPECIFICATIONS. LARGER SHRUB THE GRAPHICS AND DESIGNS � ON THIS SHEET A R E ROOT BALLS, SOIL SAUCER>3" HIGH - MAKE DEPTH MIN. AT ALL TIMES PROPERTY DELIVERABLES THAT II OF REMOVE AT END OF 4" DEEPER THAN �� STACK ROCK GROUP, INC. PROJECT BALL) _ I � BALL AND BURLAP PLANT(IF REPRODUCTION OR REUSE OF CUT AND FOLD WIRE - CONTAINER-GROWN PLANT ` THIS PRODUCT CONTAINED BASKET FROM TOP OF SOIL SURFACE WITH ROOTS LOOSENED AND HERE IN IS PROHIBITED ROOTBALL COMPACT SOIL UNDER ROUGHENED TO PULLED OUT TO PREVENT WITHOUT THE WRITTEN ROOTBALL TO 90% PROCTOR. BIND WITH NEW SOIL PLANT FROM BECOMING ROOT CONSENT OF STACK ROCK BOUND) G R O U P I N C BALL & BURLAP TREE PLANTING SHRUB PLANTING _ ROC KGRO PC NC. 1 2 - 3/4"= 1'-0" 3293-01 1" = 1'-0" 329333-03 Seals PRELIMINARY NOTE: I I PEE OF *POSTS, CONNECTIONS, SLATS& FOOTINGS BY CONTRACTOR EXISTING TREES TO REMAIN WHERE POSSIBLE, �� �� H y° PRESERVE&PROTECT TOP RAIL ANY TREES DAMAGED/DESTROYED/REMOVED \ 0 DURING CONSTRUCTION SHALL BE c� POST BY CONTRACTOR REPLACED/MITIGTATED ON A 1:1 RATIO AN ARBORIST REPORT IS RECOMMENDED TO s LA-16733 VERTICAL SLATS EVALUATE WHICH TREES NEED MITIGATED FO .22.22 P� 4gNDSCAPE NOT FOR CONSTRUCTION I I I I w � I I I I _ I I I I I 0 Z I I I I O U) > - - N O Cn �r ^ J I FOOTING BY CONTRACTOR I L.J I CJ) f UJ i f CLOSED VISION FENCE 3 _ = - to vow 1/2"= 1'-0" 323129.23-02 _ t; _ _ UJ LANDSCAPE NOTES: I _ _ I X .r Z) o 1. REGULATIONS & STANDARDS contain rocks, sticks, lumps, or toxic matter and has a pH of fully intact. Q 1.1. All contractor work shall be conducted in accordance with 6.5-8.0. 8.4. Install outdoor rated controller in specified location on plan, in a I • ISPWC (Idaho Standard Public Works Construction), 2020 (or 4.5. Smooth, compact, and fine grade topsoil in lawn areas to lock box with 2 keys. Coordinate with project manager and T' ; I I W most recent published); and City of Meridian, ID codes, smooth and uniform grade .5" below adjacent surfaces. general contractor on exact location. Ir Q Q standards and state and local regulations. 4.6. Amend all new plantings with 2 parts topsoil, 1 part compost. 8.4.1. Controller to have On/Off rain switch or rain shut off device that N 2. EXISTING CONDITIONS 5. LAWN AREAS does not alter program. �; '� L.L U 0 2.1. All utilities shall be located prior to construction and protected. 5.1. Sodded lawn to be tall turf-type fescue, or approved other. 8.5. All remote control valves (including master control valve)to _L y ■ Any damage to structures, utilities or concrete will be replaced 5.2. Sodded lawn to be regionally/locally harvested, lay sod within have flow control device. • �1 O W at contractor's expense. 24 hours of harvesting. 8.6. Irrigation system piping to be minimum class 200 PVC or - J. 2.2. The site has many existing improvements such as underground 5.3. Lay sod to form a solid mass with offset, tightly fitted joints on approved equal, sleeves to be double the size of pipes located ■• utilities, curb and gutter, light poles and sidewalks. even grades. within, all wires to be contained in separate sleeves 1-1/2" dia y 2.3. See Engineer's plans for information about existing features. 5.4. Any existing lawn that is damaged shall be replaced with min. REVISIONS 2.3.1. Refer to civil plans for all existing and/or proposed drainage sodded lawn of the same type of existing lawn. 8.7. All pipe above 3" caliper to be gasketed, with approved joint pipes & locations, utilities. Protect all drainage at all times, 5.5. All lawn areas adjacent to planter beds, gravel areas, or restraints at all 45, TEE, ELL, 22, 11. �, I MIRK DATE Description protect all utilities at all times. aggregate pathways shall have 4" black steel edging installed 8.8. Use common trenching where possible.. ® ** ** 3. GRADING & SITE PREPARATION per manufacturer recommendations. Other applications to be 8.9. All PVC located under hardscapes to be schedule 40 PVC with 3•1� • - 3.1. Prepare finish grades for planting by grubbing and removing approved by owner and landscape architect. same req's as above. I �' weeds. If necessary apply Round-Up (or equivalent herbicide), 5.6. Lawn adjacent to buildings, structures shall be a minimum of 8.10. All wires to be Paige wire 7350 or 7351 direct bury wire at a .I■ using a certified applicator. Remove rocks and other materials 18" away from foundations. Lawn adjacent to fences or other minimum of 12" below finished grade. over 2". screening elements shall be a minimum of 9" away. 8.11. Connect mainline to point of connection in approximate location �J 3.2. All gravel overprep to be removed and disposed of off site. 5.6.1. Install 2" chips or other approved gravel mulch type in mow strip shown on plan. z r 3.3. Finish grade to be smooth transition to allow for entire site to be at a depth of 3" over commercial grade weed barrier fabric 8.12. Contractor is responsible complying with all codes and paying a natural flowing space. installed per manufacturer recommendations. all permits necessary. Q� m 3.4. Fine grade lawn areas to elevations set by Engineer's plans 5.7. Provide tree rings with a minimum 3' diameter around all trees 8.13. Sprinkler heads shall have matched precipitation within each f with positive drainage away from structures. located in lawn, mulch type & installation/application to match all control circuit. Velocities shall not exceed 5 feet per second. I 3.5. Refer to Engineer's plans for grading information &for all other planter beds. 8.14. All drip irrigation to be buried 2" below finished grade. - JOB NO: 22-2922 drainage pipes and locations. Protect and retain drainage at all 6. PLANTER BED MULCH 8.15. Water schedule to be provided at a min of 80% -+_♦ DATE: 03.07.2022 times. 6.1. All planter beds to receive 3" depth of black&tan mini rock evapotranspiration as determined by the local ET. DRAWN BY: JB 3.6. No pooling or standing water will be accepted per industry mulch or approved equal, submit for approval prior to 8.16. Install all irrigation per irrigation drawings. utilize material _ _ _ CHECKED BY: JB standards. specified or approved equal. placement. Install over commercial grade weed barrier fabric p pp q _ 4. SOILS 8.17. Contractor shall confirm the static water pressure at least five DRAWING TITLE per manufacturer recommendations. 4.1. Lawn areas shall receive 12" min depth of screened topsoil. days before construction begins and to contact the landscape - "' """ - •��•�••- - P p 7. PLANTS Y 9� p —■ - 4.2. All planter beds shall receive 18" min depth of screened topsoil. 7.1. All plant material shall be installed per industry standards. architect in writing if the pressure is below 80 psi. 4.3. Reuse of existing topsoil that has been stockpiled on site is 7.2. All plant material shall meet or exceed the minimum federal 8.18. If any discrepancies are found, then local codes shall prevail. 3s"GI LANDSCAPE permitted if: standards as regulated by ANSI z60.1, American Standard for 9. CONTRACTOR RESPONSIBILITIES "GI -36"GI 4.3.1. Topsoil is tested and analyzed to ensure a proper growing Nursery Stock. Plants not meeting these standards for quality, 9.1. Estimated quantities are shown for general reference only. 36 GI PLAN medium. Provide additional amendments as determined by or plants determined to be unhealthy by Owner's representative, Contractor shall be responsible for all quantity estimates. soil tests. will be rejected. 9.2. All plant material and workmanship shall be guaranteed for a LU 4.3.2. Topsoil is to be loose, friable sandy loam that is clean and free 7.3. All Ball and Burlap trees to be installed per Balled and period of one year beginning at the date of Acceptance by w of toxic materials, noxious weeds, weed seeds, rocks, Burlapped planting detail. All shrubs to be installed per detail. Owner. Replace all dead or unhealthy plant material > LU Q grass or other foreign materials. 7.4. Trees and shrubs over 30" shall not be planted within clear immediately with same type and size at no cost to Owner. 4.3.3. Topsoil shall have a ph of 6.5 to 8.0. vision triangles. 9.3. Landscape contractor to turn in as built drawings at the end of 4.3.4. If on site topsoil does not meet these minimum standards 7.5. Fertilize all trees and shrubs with 'Agriform' planting tablets or project. Substantial completion will not be granted until 2 copies SHEET NUMBER contractor is responsible for providing approved imported approved equal. Apply per manufacturers recommendations. @ 1"=20' scale are turned in and approved by owner's 0 20 40 60 feet W PRODUCER D R topsoil or improving onsite topsoil per the approval of the 8. IRRIGATION representative. L100 project manager. 8.1. Irrigation system shall be built to the following specifications: 10. In the event of a discrepancy, notify the Landscape Architect Y 4.4. If imported topsoil is used it must be from a local source and be 8.2. Adhere to city codes when connecting to city water. immediately. NORTH SCALE: 1" = 20' 0 screened free of any debris or foreign matter. Topsoil must not 8.3. All irrigation material to be new with manufacturers'warranty Y U Q H U 1 2 1 3 14 5 6 7 8 9 10