PZ - Elevations and Floor PlansGroup#15Group#15WH WS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 FLOOR AREA SCALE 1/4" = 1'0" 1891 SF 1ST FLR 2127 SF TOTAL 422 SF GARAGE 160 SF PATIO 236 SF 2ND FLR 3' - 8"3' - 6"3' - 6"3' - 8"3' - 4"10' - 0"3' - 4"2' - 9"3' - 6"2' - 9" 14' - 4"16' - 8"9' - 0" 40' - 0"2' - 5 1/2"3' - 6"23' - 1 3/4"5' - 10 3/4"6' - 1"7' - 7 3/4"7' - 10 3/4"6' - 4 1/2"2' - 10 1/2"12' - 0"2' - 7"5' - 8"2' - 5"10' - 7"6' - 9"25' - 10 1/2"65' - 10 1/2"4' - 11"2' - 6"2' - 6"7' - 5 1/2"6' - 10 1/2"10' - 0"14' - 0"7' - 7"6' - 0"6' - 2"40' - 2 1/2"7' - 5"6' - 4 1/2"14' - 0"68' - 0"3' - 3"40' - 0" 1' - 7 1/4"16' - 0"1' - 7 1/4"2' - 11"2' - 10 1/2"4' - 0"3' - 6"3' - 6"4' - 0" 19' - 2 1/2"5' - 9 1/2"15' - 0" 6' - 11"3' - 2"19' - 11 3/4"7' - 10 1/2"4' - 11 1/2"3' - 3 1/2"3' - 7 1/2"3' - 0"3' - 9 1/2" 4' - 11 1/2" 6' - 3"7' - 0 1/2"7' - 7" 4' - 6"3' - 5 3/4"3' - 5 1/2"7' - 8 1/4"6' - 3"3' - 9 1/2"10' - 10" 2' - 0"2' - 0"4' - 10 1/2"(TYP) 2' - 0"14' - 2 3/4"10' - 2 3/4"7' - 0 1/2"9' - 3"7' - 9 3/4"11' - 3 3/4"2' - 5 1/2"2' - 5"4' - 6"3' - 0"2' - 9"3' - 6 1/2"7' - 8 1/4"6' - 0"BUILT-IN ENTRY 10' CLG LAMINATE BEDROOM 2 10' CLG CARPET BATHROOM 10' CLG TILE BEDROOM 3 10' CLG CARPET GREAT ROOM TREY LAMINATE KITCHEN 10' CLG LAMINATE DINING ROOM 10' CLG LAMINATE PANTRY 10' CLG LAMINATE TECH ROOM 10' CLG LAMINATE MASTER BEDROOM VAULT CARPET MASTER BATH 10' CLG TILE W.I.C. 10' CLG CARPET LAUNDRY 10' CLG LAMINATE MUD ROOM 10' CLG LAMINATE3' - 0"18' - 8" 1' - 0" 1' - 6" 3' - 1" 11' - 8" 5' - 10"5' - 10"22' - 11 1/4"6' - 5 3/4"2' - 2 1/4" 4' - 0" BONUS ROOM VAULT CLG 3' - 11"3' - 0"4' - 2"22' - 11 1/4"5' - 3 3/4"4' - 11"MAIN LEVEL 0' -0" CEILING 10' -1 1/8" TOP PLATE 11' -1 1/8" 1/2" GYPSUM BOARD VERIFY RISE AND RUN PRIOR TO CONSTRUCTION FOR EXACT STAIR LAYOUT TOTAL RISE: 11' -1 1/8" RISER HEIGHT: 7 13/32" TREAD DEPTH: 11" NUMBER OF RISERS: 18 1" OSB TREAD 1" OSB NOSING HANDRAIL PER R311.7.7 NOTES: 1. INSTALL SELF-CLOSING FIRE DOOR BETWEEN GARAGE AND LIVING SPACE. 2. INSTALL 5/8" GYPSUM BOARD ON ALL GARAGE WALL SURFACES ADJACENT TO LIVING SPACES. 3. SAFETY GLAZING REQ'D FOR ALL GLASS WITHIN 18" OF FLOOR OR GREATER THAN 9 SQ. FT. IN AREA. 4. SAFETY GLAZING REQ'D FOR ALL GLASS WITHIN 24" ARC OF DOORS. 5. CONTRACTOR TO VERIFY WIN. HEIGHTS WITH FRAMER BEFORE CONSTRUCTION. 6. ALL ANGLES 45° U.N.O 7. R-302 PROVIDE FIREBLOCKING AS REQUIRED. . Date Drawn by Checked by J C E SD E S I G N + V i s u a l i z a t i o nPRELIMINARY DRAWINGS (NOT FOR CONSTRUCTION) CONTRACTOR TO REVIEW DRAWINGS PRIOR TO BIDDING AND CONSTRUCTION. ANY ERRORS AND OMISSIONS SHALL BE BROUGHT TO THE ATTENTION OF THE DRAFTER/DESIGNER FOR CORRECTION. FINAL DRAWINGS CURRENT REVISION: PLAN CONFORMS TO OR REQUIRES: PRESCRIPTIVE CODE (IRC 2012 WALL BRACING) ENGINEERING PERFORMED AND INDICATED ON DWG IF SPECIAL ENGINEERING IS REQUIRED, VERIFY ALL ENGINEERING IS INDICATED ON PLANS PRIOR TO CONSTRUCTION SPECIAL ENGINEERING 8/29/2022 3:27:19 PMA1LOT 6 BLOCK 35088 N. BrockAve. Meridian,ID 836465/02/2022 Brigham Ricks Dustin Hadfield FLOOR PLAN 1/4" = 1'-0"1 MAIN LEVEL 1/4" = 1'-0"2 UPPER LEVEL 1/2" = 1'-0"3 STAIR SECTION MAIN LEVEL 0' -0" CEILING 10' -1 1/8" TOP PLATE 11' -1 1/8" APPROX. BLDG. HGHT. 24' -7 1/8"5' - 6"MAIN LEVEL 0' -0" CEILING 10' -1 1/8" TOP PLATE 11' -1 1/8" APPROX. BLDG. HGHT. 24' -7 1/8" MAIN LEVEL 0' -0" CEILING 10' -1 1/8" TOP PLATE 11' -1 1/8" APPROX. BLDG. HGHT. 24' -7 1/8" MAIN LEVEL 0' -0" CEILING 10' -1 1/8" TOP PLATE 11' -1 1/8" APPROX. BLDG. HGHT. 24' -7 1/8" Date Drawn by Checked by J C E SD E S I G N + V i s u a l i z a t i o nPRELIMINARY DRAWINGS (NOT FOR CONSTRUCTION) CONTRACTOR TO REVIEW DRAWINGS PRIOR TO BIDDING AND CONSTRUCTION. ANY ERRORS AND OMISSIONS SHALL BE BROUGHT TO THE ATTENTION OF THE DRAFTER/DESIGNER FOR CORRECTION. FINAL DRAWINGS CURRENT REVISION: PLAN CONFORMS TO OR REQUIRES: PRESCRIPTIVE CODE (IRC 2012 WALL BRACING) ENGINEERING PERFORMED AND INDICATED ON DWG IF SPECIAL ENGINEERING IS REQUIRED, VERIFY ALL ENGINEERING IS INDICATED ON PLANS PRIOR TO CONSTRUCTION SPECIAL ENGINEERING 8/29/2022 3:27:25 PMA2LOT 6 BLOCK 35088 N. BrockAve. Meridian,ID 836465/02/2022 Savanna Gurney Dustin Hadfield ELEVATIONS 1/4" = 1'-0"1 FRONT ELEVATION 1/4" = 1'-0"2 REAR ELEVATION 1/4" = 1'-0"3 LEFT ELEVATION 1/4" = 1'-0"4 RIGHT ELEVATION Dryer Washer Group#15Group#15FLOOR AREA SCALE 1/4" = 1'0" 1923 SF 1ST FLR 1923 SF TOTAL 426 SF GARAGE 160 SF PATIO5' - 0"8' - 1"13' - 7"6' - 9 1/4"14' - 2 3/4"9' - 4 1/4"4' - 6"3' - 5"10' - 5"3' - 9"4' - 3"5' - 8"3' - 6 1/2"2' - 5 3/4"12' - 2" 6' - 6" 3' - 11"4' - 1"2' - 5"3' - 9"11' - 2 1/2"7' - 0 1/2"7' - 7" 3' - 2"6' - 0"3' - 8 1/2"3' - 5 1/2"7' - 4 1/2" 8'-6" x 3'-6" 1' - 6"4' - 10 1/2"2' - 8"2' - 2 1/2"10' - 10" 5' - 11 3/4"6' - 7 3/4"6' - 6"2' - 1 1/2"2' - 9"4' - 10 1/2"ENTRY 10' CLG LAMINATE BEDROOM 2 10' CLG CARPET BATHROOM 10' CLG TILE BEDROOM 3 10' CLG CARPET GREAT ROOM TREY LAMINATE DINING ROOM 10' CLG LAMINATE KITCHEN 10' CLG LAMINATE PANTRY 10' CLG LAMINATE OFFICE 10' CLG LAMINATE MASTER BEDROOM TREY CARPET MASTER BATH 10' CLG TILE W.I.C. 10' CLG CARPET LAUNDRY 10' CLG LAMINATE MUD ROOM 10' CLG LAMINATE GARAGE 10' CLG 2' - 5 1/2"3' - 6"19' - 10 3/4"3' - 1 3/4"3' - 7 1/2"2' - 4 1/2"6' - 1"2' - 6 1/2"2' - 11 3/4"5' - 1 1/4"2' - 4"6' - 4 1/2"2' - 10 1/2"11' - 7"2' - 7"5' - 6"2' - 7"11' - 0"6' - 9 1/4"25' - 10 1/4"65' - 10 1/2"2' - 1 1/2"68' - 0"5' - 3"4' - 6"5' - 3" 2' - 11 1/4"2' - 11 1/4"6' - 7"8' - 8 1/2"9' - 6 3/4"9' - 6 3/4" 19' - 1 1/2"5' - 10 1/2"15' - 0" 40' - 0"6' - 2"6' - 0"7' - 7"5' - 8"4' - 7"2' - 3 1/2"3' - 9 1/2"4' - 1 1/2"3' - 6 1/2"3' - 6 1/2"3' - 2 1/2"3' - 2"4' - 2"2' - 6"2' - 6"5' - 2"14' - 4"6' - 4 1/2"7' - 1"7' - 11"6' - 10 1/2"25' - 5"68' - 0"3' - 8"3' - 6"3' - 6"3' - 8"2' - 9"3' - 6"2' - 9" 14' - 4"16' - 8"9' - 0" 40' - 0"6' - 0"7' - 3 3/4"16080 3' - 7"4' - 0 1/2" 18' - 8" 1' - 0"3' - 0"NOTES: 1. INSTALL SELF-CLOSING FIRE DOOR BETWEEN GARAGE AND LIVING SPACE. 2. INSTALL 5/8" GYPSUM BOARD ON ALL GARAGE WALL SURFACES ADJACENT TO LIVING SPACES. 3. SAFETY GLAZING REQ'D FOR ALL GLASS WITHIN 18" OF FLOOR OR GREATER THAN 9 SQ. FT. IN AREA. 4. SAFETY GLAZING REQ'D FOR ALL GLASS WITHIN 24" ARC OF DOORS. 5. CONTRACTOR TO VERIFY WIN. HEIGHTS WITH FRAMER BEFORE CONSTRUCTION. 6. ALL ANGLES 45° U.N.O 7. R-302 PROVIDE FIREBLOCKING AS REQUIRED. . Date Drawn by Checked by J C E SD E S I G N + V i s u a l i z a t i o nPRELIMINARY DRAWINGS (NOT FOR CONSTRUCTION) CONTRACTOR TO REVIEW DRAWINGS PRIOR TO BIDDING AND CONSTRUCTION. ANY ERRORS AND OMISSIONS SHALL BE BROUGHT TO THE ATTENTION OF THE DRAFTER/DESIGNER FOR CORRECTION. FINAL DRAWINGS CURRENT REVISION: PLAN CONFORMS TO OR REQUIRES: PRESCRIPTIVE CODE (IRC 2012 WALL BRACING) ENGINEERING PERFORMED AND INDICATED ON DWG IF SPECIAL ENGINEERING IS REQUIRED, VERIFY ALL ENGINEERING IS INDICATED ON PLANS PRIOR TO CONSTRUCTION SPECIAL ENGINEERING 8/29/2022 3:31:53 PMA1Lot 2 Block 2 -4991 N. BrockAve. Meridian,ID 8364605/25/2022 Caloy Saliva Dustin Hadfield FLOOR PLAN 1/4" = 1'-0"1 MAIN LEVEL MAIN LEVEL 0' -0" CEILING 9' -11 19/32" TOP PLATE 11' -1 1/8" APPROX. BLDG. HGHT. 23' -6 17/32" MAIN LEVEL 0' -0" CEILING 9' -11 19/32" TOP PLATE 11' -1 1/8" APPROX. BLDG. HGHT. 23' -6 17/32" MAIN LEVEL 0' -0" CEILING 9' -11 19/32" TOP PLATE 11' -1 1/8" APPROX. BLDG. HGHT. 23' -6 17/32" MAIN LEVEL 0' -0" CEILING 9' -11 19/32" TOP PLATE 11' -1 1/8" APPROX. BLDG. HGHT. 23' -6 17/32" Date Drawn by Checked by J C E SD E S I G N + V i s u a l i z a t i o nPRELIMINARY DRAWINGS (NOT FOR CONSTRUCTION) CONTRACTOR TO REVIEW DRAWINGS PRIOR TO BIDDING AND CONSTRUCTION. ANY ERRORS AND OMISSIONS SHALL BE BROUGHT TO THE ATTENTION OF THE DRAFTER/DESIGNER FOR CORRECTION. FINAL DRAWINGS CURRENT REVISION: PLAN CONFORMS TO OR REQUIRES: PRESCRIPTIVE CODE (IRC 2012 WALL BRACING) ENGINEERING PERFORMED AND INDICATED ON DWG IF SPECIAL ENGINEERING IS REQUIRED, VERIFY ALL ENGINEERING IS INDICATED ON PLANS PRIOR TO CONSTRUCTION SPECIAL ENGINEERING 8/29/2022 3:32:02 PMA2Lot 2 Block 2 -4991 N. BrockAve. Meridian,ID 8364605/25/2022 Caloy Saliva Dustin Hadfield ELEVATIONS 1/4" = 1'-0"1 FRONT ELEVATION 1/4" = 1'-0"2 REAR ELEVATION 1/4" = 1'-0"3 LEFT ELEVATION 1/4" = 1'-0"4 RIGHT ELEVATION Group#15Group#155' - 0"16' - 0"10' - 4"3' - 0"6' - 3 1/2"5' - 0"6' - 3 1/2"4' - 10 1/2"6' - 6 1/2"2' - 5 1/2"4' - 11 3/4"5' - 0"13' - 9"16' - 3 1/2"11' - 0"3' - 6"3' - 9"2' - 0"8' - 6"4' - 6 1/2"17' - 7"2' - 0 1/4"3' - 7 1/2"3' - 6"3' - 6"3' - 7 1/2"15' - 7"3' - 3 3/4"3' - 6"3' - 4 1/4" 4' - 10 5/8"4' - 5 3/4"4' - 10 5/8"2' - 5"2' - 5"2' - 5 1/2"16' - 0"2' - 5 1/2"3' - 5 1/2"5' - 0"3' - 0"2' - 5 1/2"2' - 9 1/2"2' - 6"2' - 5 1/2"2' - 11 1/4"5' - 8 1/2"2' - 7 3/4"6' - 8 1/2"3' - 6 1/2"3' - 3"3' - 6 1/2"3' - 3"3' - 3 1/2"10' - 0"3' - 5 1/2"9' - 3 7/8"8' - 10 1/8"8' - 10 1/8"10' - 4 1/8"1' - 8 3/4"22' - 4"3' - 6"3' - 8 1/4"20' - 0"29' - 6 1/4"39' - 1"1' - 4 3/4"70' - 0"14' - 3"15' - 7"10' - 2" 40' - 0" 14' - 3"4' - 10"20' - 11" 40' - 0"0' - 0"17' - 1"14' - 1 1/2"30' - 5 1/4"3' - 0"6' - 0"4' - 6"4' - 6"13' - 4" 10' - 0"3' - 4"2' - 2"11' - 0"11' - 5 1/2"10' - 2 1/2"11' - 3 1/2"20' - 3 1/2"16' - 9"13' - 4"60" X 32"SOAKING TUB3' - 9"6' - 6"3' - 2 1/2" 3' - 1" 16' - 2 1/2" 10' - 0"6' - 6"10' - 3 1/2"9' - 8 1/2"5' - 6"11' - 1 1/2"3' - 5"4' - 11"4' - 0"6' - 3 1/2"16' - 7 1/2"5' - 4 1/2"1' - 10"2' - 4"2' - 4"7' - 10 1/2"1' - 6"1' - 7"ENTRY 10' CLG LAMINATE BEDROOM 2 10' CLG CARPET BATH 10' CLG TILE BEDROOM 3 10' CLG CARPET MUD / LAUNDRY 10' CLG LAMINATE GREAT ROOM VAULT LAMINATE MASTER BEDROOM VAULT CARPET M. BATH 10' CLG TILE W.I.C. 10' CLG CARPET DINING ROOM 10' CLG LAMINATE KITCHEN 10' CLG LAMINATE PANTRY 10' CLG LAMINATE OFFICE 10' CLG LAMINATE GARAGE W/ TANDEM 10' CLG CONCRETE PATIO 10' CLG CONCRETE 70' - 0"FLOOR AREA SCALE 1/4" = 1'0" 1842 SF 1ST FLR 1842 SF TOTAL 586 SF GARAGE 181 SF PATIO 1/4" = 1'-0"1 MAIN LEVEL Date Drawn by Checked by PRELIMINARY DRAWINGS (NOT FOR CONSTRUCTION) CONTRACTOR TO REVIEW DRAWINGS PRIOR TO BIDDING AND CONSTRUCTION. ANY ERRORS AND OMISSIONS SHALL BE BROUGHT TO THE ATTENTION OF THE DRAFTER/DESIGNER FOR CORRECTION. FINAL DRAWINGS CURRENT REVISION: PLAN CONFORMS TO OR REQUIRES: PRESCRIPTIVE CODE (IRC 2012 WALL BRACING) ENGINEERING PERFORMED AND INDICATED ON DWG IF SPECIAL ENGINEERING IS REQUIRED, VERIFY ALL ENGINEERING IS INDICATED ON PLANS PRIOR TO CONSTRUCTION SPECIAL ENGINEERING 8/29/2022 3:28:55 PMA1Lot 5 Block 3 -5104 N. Brock Ave.Meridian, ID 8364605/24/2022 CALOY SALIVA DUSTIN HADFIELD FLOOR PLAN MAIN LEVEL 0' -0" CEILING 10' -1 1/8" TOP PLT. 19' -1 1/8" UPPER LEVEL 11' -1 1/8" APPROX. BLDG. HGHT. 25' -7 1/8" MAIN LEVEL 0' -0" CEILING 10' -1 1/8" TOP PLT. 19' -1 1/8" UPPER LEVEL 11' -1 1/8" APPROX. BLDG. HGHT. 25' -7 1/8" 1/4" = 1'-0"1 FRONT ELEVATION 1/4" = 1'-0"2 REAR ELEVATION Date Drawn by Checked by PRELIMINARY DRAWINGS (NOT FOR CONSTRUCTION) CONTRACTOR TO REVIEW DRAWINGS PRIOR TO BIDDING AND CONSTRUCTION. ANY ERRORS AND OMISSIONS SHALL BE BROUGHT TO THE ATTENTION OF THE DRAFTER/DESIGNER FOR CORRECTION. FINAL DRAWINGS CURRENT REVISION: PLAN CONFORMS TO OR REQUIRES: PRESCRIPTIVE CODE (IRC 2012 WALL BRACING) ENGINEERING PERFORMED AND INDICATED ON DWG IF SPECIAL ENGINEERING IS REQUIRED, VERIFY ALL ENGINEERING IS INDICATED ON PLANS PRIOR TO CONSTRUCTION SPECIAL ENGINEERING 8/29/2022 3:28:57 PMA2Lot 5 Block 3 -5104 N. Brock Ave.Meridian, ID 8364605/24/2022 CALOY SALIVA DUSTIN HADFIELD ELEVATIONS MAIN LEVEL 0' -0" CEILING 10' -1 1/8" TOP PLT. 19' -1 1/8" UPPER LEVEL 11' -1 1/8" APPROX. BLDG. HGHT. 25' -7 1/8" MAIN LEVEL 0' -0" CEILING 10' -1 1/8" TOP PLT. 19' -1 1/8" UPPER LEVEL 11' -1 1/8" APPROX. BLDG. HGHT. 25' -7 1/8" 1/4" = 1'-0"1 LEFT ELEVATION 1/4" = 1'-0"2 RIGHT ELEVATION Date Drawn by Checked by PRELIMINARY DRAWINGS (NOT FOR CONSTRUCTION) CONTRACTOR TO REVIEW DRAWINGS PRIOR TO BIDDING AND CONSTRUCTION. ANY ERRORS AND OMISSIONS SHALL BE BROUGHT TO THE ATTENTION OF THE DRAFTER/DESIGNER FOR CORRECTION. FINAL DRAWINGS CURRENT REVISION: PLAN CONFORMS TO OR REQUIRES: PRESCRIPTIVE CODE (IRC 2012 WALL BRACING) ENGINEERING PERFORMED AND INDICATED ON DWG IF SPECIAL ENGINEERING IS REQUIRED, VERIFY ALL ENGINEERING IS INDICATED ON PLANS PRIOR TO CONSTRUCTION SPECIAL ENGINEERING 8/29/2022 3:28:59 PMA3Lot 5 Block 3 -5104 N. Brock Ave.Meridian, ID 8364605/24/2022 CALOY SALIVA DUSIN HADFIELD ELEVATIONS UP WH WDGroup#15Group#15DN70' - 0"40' - 0" 13' - 3 1/2"6' - 0"20' - 8 1/2"70' - 0"13' - 7 3/8"41' - 9 1/2"9' - 8 5/8"4' - 10 1/2"14' - 7 1/8"6' - 5 3/8"6' - 0"7' - 5"35' - 6 1/2"40' - 0" 13' - 1"12' - 0"14' - 11" 2' - 9 9/16"3' - 2 1/2"3' - 2 1/2"2' - 9 7/16" 3' - 0"3' - 0"10' - 4 1/4"10' - 4 1/4" 1' - 4"10' - 7 1/2"1' - 4"1' - 4"4' - 8"4' - 3"3' - 2 1/2"3' - 2 1/2"4' - 3"3' - 0 5/16"9' - 0"2' - 6 13/16"3' - 5 3/8"3' - 0"1' - 7 3/4"4' - 4 1/4"2' - 4 1/2"8' - 1 1/4"9' - 0"9' - 0"7' - 0 3/4"3' - 5 1/4"3' - 2 1/2"3' - 2 1/2"3' - 5 1/4"3' - 5 1/2"6' - 3"3' - 3 1/2"21' - 6 1/2"7' - 11 1/8"3' - 5 1/2"6' - 0 1/2"4' - 5 1/2"8' - 8" 1' - 9 1/4"10' - 0"1' - 3 3/4" 2' - 0"2' - 0"2' - 0"21' - 6 1/2"9' - 2 15/16"5' - 10 1/16"0' - 11"9' - 9 1/2" 3' - 4 1/4"3' - 9 3/8"8' - 10"4' - 9 1/2"1' - 1"5' - 10 1/16"2' - 3" 0' - 10 3/4" 2' - 10 3/4"3' - 5 1/2"3' - 2 1/2" 4' - 6 1/2"1' - 9"7' - 6 1/4"15' - 4 1/2"13' - 3 1/8"1' - 4"1' - 4"23' - 9"6' - 0 1/2"5' - 0 7/8"FURNACE 10' CEILING 13' - 0"7' - 4 5/8"4' - 8 1/2"7' - 2 3/8"9' - 6"2' - 4 1/2"2' - 6"4' - 10 5/16"4' - 10 5/16"3' - 11 1/16"3' - 5 9/16"3' - 7 3/16"3' - 7 3/16"1' - 9" 2' - 11"5' - 9 1/2"6' - 4 3/8"12' - 3"STACKED2' - 6 1/4"12' - 6 1/4" ENTRY 10' CLG LAMINATE BATHROOM 10' CLG TILE OFFICE / DEN 10' CLG CARPET LAUNDRY 10' CLG LAMINATE GREAT ROOM 10' CLG LAMINATE KITCHEN 10' CLG LAMINATE DINING ROOM TREY LAMINATE MASTER BED VAULT CARPET M. BATH 10' CLG TILE W.I.C. 10' CLG CARPET PANTRY 10' CLG LAMINATE GARAGE W/ TANDEM 10' CLG CONCRETE PORCH 10' CLG CONCRETE PATIO 10' CLG CONCRETE1' - 0"1' - 0"41' - 9 1/2"13' - 3 1/2"16' - 3" 2' - 2"7' - 3 1/2"6' - 9 1/2"19' - 3 1/2"6' - 11"15' - 7"3' - 8 3/4"6' - 9"3' - 10" 15' - 2 3/4"14' - 3 3/4" 29' - 6 1/2" 4' - 10 3/4"3' - 6"4' - 10 3/4"33' - 10 3/8"7' - 11 1/8"41' - 9 1/2"3' - 11 1/2"3' - 10 5/8"3' - 10 5/8"3' - 6" 11' - 7"3' - 8 1/4"12' - 9"13' - 5 1/2"8' - 9 5/8"1' - 10 7/8"5' - 0"6' - 6 3/4"3' - 8"3' - 5 1/2"8' - 10"3' - 3 1/2"3' - 11"12' - 0 1/2"3' - 4"29' - 6 1/2"3' - 5 1/2"6' - 0"5' - 3 7/8"MECH CHASE 2' - 11 1/2"2' - 11 1/2"3' - 9 1/2"10' - 6 1/4"14' - 9 3/8"2' - 7 1/2"10' - 6 1/2"5' - 11"2' - 0 3/4"4' - 8 3/4"7' - 5 7/8"1' - 10"1' - 10" 1' - 8 1/4"3' - 10"1' - 9 1/4" BEDROOM 2 9' CLG CARPET BONUS ROOM 9' CLG CARPET BEDROOM 3 9' CLG CARPET TECH OR STORAGE 9' CLG CARPET BATHROOM 9' CLG TILE FLOOR AREA SCALE 1/4" = 1'0" 1,480 SF 1ST FLR 983 SF 2ND FLR 2,463 SF TOTAL 559 SF GARAGE 408 SF PATIO MAIN LEVEL 0' -0" UPPER LEVEL 10' -1 1/8" FINISH FLR. 11' -1 1/8" 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 VERIFY RISE AND RUN PRIOR TO CONSTRUCTION FOR EXACT STAIR LAYOUT TOTAL RISE: 11' -1 1/8" TOTAL RUN: 19' -8 1/2" RISER HEIGHT: 7 13/32" TREAD DEPTH: 10" NUMBER OF RISERS: 18 1/2" GYPSUM BOARD0' - 7 13/32"0' - 10" 1" OSB NOSING 1" OSB TREAD HANDRAIL PER R311.7.7 1/4" = 1'-0"1 MAIN LEVEL 1/4" = 1'-0"2 UPPER LEVEL Date Drawn by Checked by J C E SD E S I G N + V i s u a l i z a t i o nPRELIMINARY DRAWINGS (NOT FOR CONSTRUCTION) CONTRACTOR TO REVIEW DRAWINGS PRIOR TO BIDDING AND CONSTRUCTION. ANY ERRORS AND OMISSIONS SHALL BE BROUGHT TO THE ATTENTION OF THE DRAFTER/DESIGNER FOR CORRECTION. FINAL DRAWINGS CURRENT REVISION: PLAN CONFORMS TO OR REQUIRES: PRESCRIPTIVE CODE (IRC 2012 WALL BRACING) ENGINEERING PERFORMED AND INDICATED ON DWG IF SPECIAL ENGINEERING IS REQUIRED, VERIFY ALL ENGINEERING IS INDICATED ON PLANS PRIOR TO CONSTRUCTION SPECIAL ENGINEERING 8/29/2022 3:23:20 PMA1Lot 5 Block 4-4986 N. brody Ave.Meridian, ID 836464/14/2022 Caleb Dean Dustin Hadfield FLOOR PLAN 3/8" = 1'-0"3 STAIR SECTION MAIN LEVEL 0' -0" UPPER LEVEL 10' -1 1/8" TOP PLT. 20' -1 1/8" FINISH FLR. 11' -1 1/8" APPROX. BLDG. HGHT. 29' -8 13/32" MAIN LEVEL 0' -0" UPPER LEVEL 10' -1 1/8" TOP PLT. 20' -1 1/8" FINISH FLR. 11' -1 1/8" APPROX. BLDG. HGHT. 29' -8 13/32" 1/4" = 1'-0"1 FRONT ELEVATION 1/4" = 1'-0"2 REAR ELEVATION Date Drawn by Checked by J C E SD E S I G N + V i s u a l i z a t i o nPRELIMINARY DRAWINGS (NOT FOR CONSTRUCTION) CONTRACTOR TO REVIEW DRAWINGS PRIOR TO BIDDING AND CONSTRUCTION. ANY ERRORS AND OMISSIONS SHALL BE BROUGHT TO THE ATTENTION OF THE DRAFTER/DESIGNER FOR CORRECTION. FINAL DRAWINGS CURRENT REVISION: PLAN CONFORMS TO OR REQUIRES: PRESCRIPTIVE CODE (IRC 2012 WALL BRACING) ENGINEERING PERFORMED AND INDICATED ON DWG IF SPECIAL ENGINEERING IS REQUIRED, VERIFY ALL ENGINEERING IS INDICATED ON PLANS PRIOR TO CONSTRUCTION SPECIAL ENGINEERING 8/29/2022 3:23:22 PMA2Lot 5 Block 4-4986 N. brody Ave.Meridian, ID 836464/14/2022 Caleb Dean Dustin Hadfield ELEVATIONS MAIN LEVEL 0' -0" UPPER LEVEL 10' -1 1/8" TOP PLT. 20' -1 1/8" FINISH FLR. 11' -1 1/8" APPROX. BLDG. HGHT. 29' -8 13/32" MAIN LEVEL 0' -0" UPPER LEVEL 10' -1 1/8" TOP PLT. 20' -1 1/8" FINISH FLR. 11' -1 1/8" APPROX. BLDG. HGHT. 29' -8 13/32" 1/4" = 1'-0"1 LEFT ELEVATION 1/4" = 1'-0"2 RIGHT ELEVATION Date Drawn by Checked by J C E SD E S I G N + V i s u a l i z a t i o nPRELIMINARY DRAWINGS (NOT FOR CONSTRUCTION) CONTRACTOR TO REVIEW DRAWINGS PRIOR TO BIDDING AND CONSTRUCTION. ANY ERRORS AND OMISSIONS SHALL BE BROUGHT TO THE ATTENTION OF THE DRAFTER/DESIGNER FOR CORRECTION. FINAL DRAWINGS CURRENT REVISION: PLAN CONFORMS TO OR REQUIRES: PRESCRIPTIVE CODE (IRC 2012 WALL BRACING) ENGINEERING PERFORMED AND INDICATED ON DWG IF SPECIAL ENGINEERING IS REQUIRED, VERIFY ALL ENGINEERING IS INDICATED ON PLANS PRIOR TO CONSTRUCTION SPECIAL ENGINEERING 8/29/2022 3:23:23 PMA3Lot 5 Block 4-4986 N. brody Ave.Meridian, ID 836464/14/2022 Caleb Dean Dustin Hadfield ELEVATIONS Group#15Group#155' - 0"16' - 0"10' - 4"3' - 0" 9' - 3 1/2"6' - 3 1/2"5' - 0"4' - 10 1/2"2' - 2 1/2"4' - 4"4' - 11 1/4"5' - 0"30' - 0 1/2"5' - 10 1/8"3' - 5 1/8"5' - 6 1/4"2' - 0"5' - 1 1/2"3' - 9"2' - 5 1/2" 2' - 0"7' - 3 1/2"4' - 1 1/2"6' - 7"3' - 0 1/2"10' - 9 1/2"2' - 9 1/2"15' - 0 1/2"2' - 0"3' - 0"6' - 0"4' - 6"4' - 6"10' - 0"3' - 4" 13' - 4" 3' - 9"3' - 2 1/2" 3' - 1"2' - 2"9' - 3 1/4"7' - 10 1/2"60" x 32"SOAKING TUBCONCRETE PAD3' - 7"3' - 4"2' - 1 5/8"4' - 5 1/8"8' - 6"4' - 6 1/2"1' - 9 1/2"1' - 9 1/2"6' - 9 1/2"ENTRY 10' CLG LAMINATE BEDROOM 2 10' CLG CARPET BEDROOM 3 10' CLG CARPET BATHROOM 10' CLG TILE GREAT ROOM VAULT LAMINATE KITCHEN 10' CLG LAMINATE DINING ROOM 10' CLG LAMINATE MUD ROOM 10' CLG LAMINATE PANTRY 10' CLG LAMINATE OFFICE 10' CLG LAMINATE MASTER BEDROOM VAULT CARPET MASTER BATH 10' CLG TILE W.I.C. 10' CLG CARPET GARAGE 10' CLG 3' - 7 1/2"3' - 6"3' - 6"3' - 7 1/2" 2' - 5"2' - 5" 10' - 5 1/2"10' - 5 1/2"3' - 5 1/2"5' - 0"3' - 3 1/2"2' - 9 1/2"2' - 6"2' - 11 1/4"5' - 8 1/2"2' - 7 3/4"3' - 5 1/2"10' - 0"3' - 0"3' - 6 1/2"3' - 3"3' - 6 1/2"3' - 3"11' - 9"2' - 5 1/2"5' - 3 1/2"2' - 5 1/2"11' - 3 1/2"6' - 8 1/2"6' - 9 1/2"6' - 9 1/2"16' - 5 1/2"3' - 7 1/2"3' - 6"3' - 6"3' - 7 1/2"3' - 4"3' - 6"3' - 4" 14' - 3"15' - 7"10' - 2" 40' - 0"3' - 8"3' - 6"21' - 10 3/4"4' - 5"12' - 2 1/2"2' - 4"5' - 10"9' - 6"5' - 3"22' - 11"16' - 7 1/2"29' - 0 3/4"68' - 7 1/4"14' - 3"4' - 10"20' - 11" 40' - 0"70' - 0"FLOOR AREA SCALE 1/4" = 1'0" 1934 SF 1ST FLR 1934 SF TOTAL 448 SF GARAGE 181 SF PATIO 1/4" = 1'-0"1 MAIN LEVEL Date Drawn by Checked by PRELIMINARY DRAWINGS (NOT FOR CONSTRUCTION) CONTRACTOR TO REVIEW DRAWINGS PRIOR TO BIDDING AND CONSTRUCTION. ANY ERRORS AND OMISSIONS SHALL BE BROUGHT TO THE ATTENTION OF THE DRAFTER/DESIGNER FOR CORRECTION. FINAL DRAWINGS CURRENT REVISION: PLAN CONFORMS TO OR REQUIRES: PRESCRIPTIVE CODE (IRC 2012 WALL BRACING) ENGINEERING PERFORMED AND INDICATED ON DWG IF SPECIAL ENGINEERING IS REQUIRED, VERIFY ALL ENGINEERING IS INDICATED ON PLANS PRIOR TO CONSTRUCTION SPECIAL ENGINEERING 8/29/2022 3:21:55 PMA1Lot 3 Block 2 -4983 N. Brock Ave.Meridian, ID 8364604/14/2022 CALOY SALIVA DUSTIN HADFIELD FLOOR PLAN NOTES: 1. INSTALL SELF-CLOSING FIRE DOOR BETWEEN GARAGE AND LIVING SPACE. 2. INSTALL 5/6" GYPSUM BOARD ON ALL GARAGE WALL SURFACES ADJACENT TO LIVING SPACES. 3. SAFETY GLAZING REQ'D FOR ALL GLASS WITHIN 18" OF FLOOR OR GREATER THAN 9 SQ. FT. IN AREA. 4. SAFETY GLAZING REQ'D FOR ALL GLASS WITHIN 24" ARC OF DOORS. 5. CONTRACTOR TO VERIFY WIN. HEIGHTS WITH FRAMER BEFORE CONSTRUCTION. 6. ALL ANGLES 45° U.N.O. 7. R-302 PROVIDE FIREBLOCKING AS REQUIRED. R308.1 GLAZING IDENTIFICATION EXCEPT AS INDICATED IN SECTION R308.1.1 EACH PANE OF GLAZING INSTALLED IN HAZARDOUS LOCATION AS DEFINED IN SECTION R308.4 SHALL BE PROVIDED WITH A MANUFACTURER'S DESIGNATION SPECIFYING WHO APPLIED THE DESIGNATION, DESIGNATING THE TYPE OF GLASS AND THE SAFETY GLAZING STANDARD WITH WHICH IT COMPLIES, WHICH IS VISIBLE IN THE FINAL INSTALLATION. THE DESIGNATION SHALL BE ACID ETCHED, SANDBLASTED, CERAMIC-FIRED, LASSER ETCHED, EMBOSSED, OR BE OF A TYPE WHICH ONCE APPLIED CANNOT BE REMOVED WITHOUT BEING DESTROYED. A LABEL SHALL BE PERMITTED IN LIEU OF THE MANUFACTURER'S DESIGNATION. R308.4 HAZARDOUS LOCATIONS. THE LOCATIONS SPECIFIED IN SECTIONS R308.4.1 THROUGH R308.4.1 SHALL BE CONSIDERED HAZARDOUS LOCATIONS FOR THE PURPOSES OF GLAZING. R302 -PROVIDE FIREBLOCKING AS REQUIRED. R302.11 FIREBLOCKING INCOMBUSTIBLE CONSTRUCTION, FIREBLOCKING SHALL BE PROVIDED TO CUT OFF ALL CONCEALED DRAFT OPENINGS (BOTH VERTICAL AND HORIZONTAL) AND TO FORM AN EFFECTIVE FIRE BARRIER BETWEEN STORIES, AND BETWEEN A TOP STORY AND THE ROOF SPACE. MAIN LEVEL 0' -0" CEILING 10' -1 1/8" TOP PLT. 19' -1 1/8" UPPER LEVEL 11' -1 1/8" APPROX. BLDG. HGHT. 25' -7 1/8" MAIN LEVEL 0' -0" CEILING 10' -1 1/8" TOP PLT. 19' -1 1/8" UPPER LEVEL 11' -1 1/8" APPROX. BLDG. HGHT. 25' -7 1/8" 1/4" = 1'-0"1 FRONT ELEVATION 1/4" = 1'-0"2 REAR ELEVATION Date Drawn by Checked by PRELIMINARY DRAWINGS (NOT FOR CONSTRUCTION) CONTRACTOR TO REVIEW DRAWINGS PRIOR TO BIDDING AND CONSTRUCTION. ANY ERRORS AND OMISSIONS SHALL BE BROUGHT TO THE ATTENTION OF THE DRAFTER/DESIGNER FOR CORRECTION. FINAL DRAWINGS CURRENT REVISION: PLAN CONFORMS TO OR REQUIRES: PRESCRIPTIVE CODE (IRC 2012 WALL BRACING) ENGINEERING PERFORMED AND INDICATED ON DWG IF SPECIAL ENGINEERING IS REQUIRED, VERIFY ALL ENGINEERING IS INDICATED ON PLANS PRIOR TO CONSTRUCTION SPECIAL ENGINEERING 8/29/2022 3:21:56 PMA2Lot 3 Block 2 -4983 N. Brock Ave.Meridian, ID 8364604/14/2022 CALOY SALIVA DUSTIN HADFIELD ELEVATIONS MAIN LEVEL 0' -0" CEILING 10' -1 1/8" TOP PLT. 19' -1 1/8" UPPER LEVEL 11' -1 1/8" APPROX. BLDG. HGHT. 25' -7 1/8" MAIN LEVEL 0' -0" CEILING 10' -1 1/8" TOP PLT. 19' -1 1/8" UPPER LEVEL 11' -1 1/8" APPROX. BLDG. HGHT. 25' -7 1/8" 1/4" = 1'-0"1 LEFT ELEVATION 1/4" = 1'-0"2 RIGHT ELEVATION Date Drawn by Checked by PRELIMINARY DRAWINGS (NOT FOR CONSTRUCTION) CONTRACTOR TO REVIEW DRAWINGS PRIOR TO BIDDING AND CONSTRUCTION. ANY ERRORS AND OMISSIONS SHALL BE BROUGHT TO THE ATTENTION OF THE DRAFTER/DESIGNER FOR CORRECTION. FINAL DRAWINGS CURRENT REVISION: PLAN CONFORMS TO OR REQUIRES: PRESCRIPTIVE CODE (IRC 2012 WALL BRACING) ENGINEERING PERFORMED AND INDICATED ON DWG IF SPECIAL ENGINEERING IS REQUIRED, VERIFY ALL ENGINEERING IS INDICATED ON PLANS PRIOR TO CONSTRUCTION SPECIAL ENGINEERING 8/29/2022 3:21:58 PMA3Lot 3 Block 2 -4983 N. Brock Ave.Meridian, ID 8364604/14/2022 CALOY SALIVA DUSIN HADFIELD ELEVATIONS