CC - Sanitary Sewer Plan & Profile r I � CLM Sheet Notes: 0 = LU I 1 1. ALL CONSTRUCTION AND MATERIAL SHALL BE IN ACCORDANCE WITH THE IDAHO STANDARDS FOR W Z O PUBLIC WORKS CONSTRUCTION (ISPWC), CITY OF MERIDIAN STANDARDS,AND ADA COUNTY HIGHWAY DISTRICT STANDARDS. NO EXCEPTIONS ARE PERMITTED WITHOUT PRIOR WRITTEN I APPROVAL. � o 2. THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE SHOWN IN AN APPROXIMATE WAY ONLY. THE CONTRACTOR SHALL COMPLY WITH IDAHO CODE, CHAPTER 22,TITLE 55 REGARDING F,o UNDERGROUND FACILITIES SAMAGE PREVENTION. THE CONTRACTOR SHALL DETERMINE THE EXACT N • LOCATION OF EXISTING UTILITIES BEFORE COMMENCING WORK. THE CONTRACTOR AGREES TO BE I 1 T \ FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT BE OCCASIONED AS A RESULT OF OHP FAILURE TO EXACTLY LOCATE AND PRESEVE ANY AND ALL UTILITIES. THE CONTRACOTR SHALL _ I OHP CONTACT THE APPROPRIATE UTILITY COMPANIES OR DIG-LINE (342-1585) FOR EXACT LOCATIONS A — — — —— — — — — — —— —� I OHP OHP MINIMUM OF 48-HOURS PRIOR TO DIGGING. r I o0.aoa I � OHP � Ep dHP Of ___ OHP �Fp— EP 3. COMPLY WITH ALL NOTES ON SHEET C1.00. co 1 4. CONTRACTOR TO FIELD VERIFY ALL EXISTING CURB AND GUTTER, STORM DRAIN,AND SEWER cc ,�`, I I o ELEVATIONS OR INVERTS PRIOR TO CONSTRUCTION AND NOTIFY ENGINEER WHEN ELEVATIONS OR /,0#To 8"W — ° W 8I'W INVERTS DO NOT MATCH PLANS. CL W U-1 I 5. ALL PIPE INSTALLATION AND TRENCHING SHALL CONFORM TO THE LATEST EDITION OF THE ISPWC DIVISION 300 AND SD-301. BEDDING AND BACKFILL SHALL BE CONSTRUCTED PER SECTIONS 305 AND W BECKY DR. 306 OF THE ISPWC. CL 0+00 30-LF OF 6-IN PVC AT 24.00% I w I 55-LF OF 8-IN PVC AT 8.00% w I 0+85 Keynotes: �O 6 SS SA g"SS c�N IE: 2513.02 1 I I I 1. INSTALL SEWER SERVICE STUB PER ISPWC SD-512. I I SSI STRC 1.0 I I �S1 MH 3 2. 16-IN STEEL CASING PIPE (3/8-IN (MIN.)WALL THICKNESS, CONFORMING TO ASTM A252) PER CITY OF — — — — — — — — — — — w MERIDIAN SUPPLEMENTAL SPECIFICATIONS TO THE ISPWC STANDARD DRAWING SW1 &SW2,THIS o000000000000 I 1 ------- EP ______ ---------- EP SHEET. CONTRACTOR SHALL CONFIRM CASING DIMENSIONS, BRING ANY DISCREPANCIES TO 0000000000000 L — — —— — — —— ENGINEER'S ATTENTION.3'MIN. SEPARATION BETWEEN CASING AND LOWEST PART OF Cl)o EP WATERWAY/PIPE. SEAL ENDS OF CASING WITH 3/8-IN NEOPRENE SEAL WITH STAINLESS STEEL _ n BANDS. l w I �Q 1 / 3. PRESERVE AND PROTECT EXISTING GRAVITY IRRIGATION PIPE DURING CONSTRUCTION. cc I o - LD I �Q LU I T Cn � 30 I o ' GRAVITY IRRIGATION EASEMENT I � i W I I LU n I I r w I I I I I I - NONPOTABLE PIPE OR DITCH GROUND SURFACE I I II I IIIII I IIIII I III IIIII I IIIII I IIIII I IIIII I IIIII I IIIII I I II I II III IIIII I IIIII I IIIII I IIIII I IIIII I IIIII I IIIII 11 I I I—III—III—III=III=III=III=III—III I I 1=111=111=11 I—III=I 11=111—III—I 11- —I I I—I I I III III III III III 111= '=1 I I I I I I I MI I I I I I—I I I=1 I MI 11 I I I—I 11=1 11=1 I I—I 11=1 11=1 I I I I I I= D 'I I, I I I 1=I I I=1 11=I 11=I I I=1 11=I 1 I= =1 I I—I 11=1 I I—III—III—III_ =1 I I—III III—III—III—I I SanitarySewer Plan & Profile o io' 2I EEIII 1—III-111=1—�� 11I-11 E1E E1_=1 I I=I I I=III=1111:III 15 'III — — I I I=III=III=III= -1 I I—III—III—III= Horizontal Scale: 1" = 10' —III1I1—_I I X III-1I1=111= III—III; IIIII— III=,I_ 7,7"7 1.5X - 2540 2540 3X+D SSwR: Sta. -0+50 - 1 +OO NEOPRENE END STEEL CASING HORIZONTAL SCALE: 1" = 10' SEAL(EACH END) ANNULAR FILL WATER,SEWER OR RECYCLED VERTICAL SCALE: 1" = 4' WATER CARRIER PIPE PROPOSED GROUND AT PIPE 2535 CENTER LINE 2535 NOTES _ 1. CASING LENGTH SHALL BE AT LEAST 3X+D IN LENGTH,WHERE X IS THE _ ———————— DISTANCE FROM THE CENTER OF THE NONPOTABLE PIPELINE OR DITCH r TO THE REQUIRED BOTTOM OF THE CASING AND D IS THE DIAMETER OF / THE IRRIGATION PIPELINE.(MINIMUM CASING LENGTH SHALL BE 20') 2530 _______ 2530 2. CASING SHALL BE CENTERED UNDER IRRIGATION PIPELINE ——— 3. ANNULAR SPACE SHALL BE FILLED PER ISPWC AND CITY SUPPLEMENTAL SPECIFICATIONS.SEE SECTIONS 308 AND 310 21-IN RCP CROSSINGO3 EXISTING GROUND AT PIPE CENTER LINE 2525 2525 REVISED JULY 2014 CITY OF MERIDIAN ■ SUPPLEMENTAL SPECIFICATIONS CASING LENGTH REQUIREMENT S �nTO THE IDAHO STANDARDS FOR V V PUBLIC WORKS CONSTRUCTION 2520 2520 C 0 �■■r co 2515 2515 mime FOR OSLEVE/E/CASING LENGTH PVC OR STEEL SLEEVE/CASING cc cc IE: 2513.02—Z ("D" = DIAMETER) DETERMINED BY SIZE OF LINE TO SLEEVE/CASE. O � SEE SECTION 308 & 310. c-p ■ � 00 2510 2510 PLASTIC SKIDS 0 CALPICO INC. MODEL PX Q U 0 OR APPROVED EQUIV. 30-LF OF 6-IN PVC AT 24.00% SPACED ® 6.5' O.C. c Lo E5 a M -CD i 1/2" MAX. TOLERANCE M BETWEEN END OF SPACER AND PVC WATER, INSIDE OF SLEEVE/CASING. 2505 2505 RECYCLED WATER Revisions 55_LF OF OR SEWER PIPE ANNULAR SPACE 8-IN P SS STRC 1.0 2 16"CASING V C qT 8 00, (S BE FILLED 1 48-IN MH PER ISPWC SD-501 STA: 0+35.19 (SEE NOTE 6) STA: 0+30, 0.00' RIM: 2531.00± 16"CASING 2500 IE IN: 2505.82, 6-IN PVC (W) STA: 0+78.54 2 2500 IE OUT: 2505.65, 8-IN PVC (E) NOTES 1. VERIFY ALL DIMENSIONS AND ELEVATIONS IN THE FIELD PRIOR TO CONSTRUCTION. 2. PIPE SLEEVE/CASING ASSEMBLY SHALL BE INSPECTED BY MERIDIAN PUBLIC WORKS DEPARTMENT PRIOR TO INSTALLATION IN THE TRENCH. SSMH 3 3. WATER-TIGHT BOOTS SHALL BE INSTALLED ON EACH END OF THE PIPE 60-IN MH BY OTHERS SLEEVE/CASING. 2495 STA: 0+85, 0.00' 2495 4. BELL RESTRAINTS ARE REQUIRED ON ALL WATER, RECYCLED WATER AND PROPOSED GROUND ELEVATION RIM: 2532.81± PRESSURE SEWER PIPING PLACED WITHIN THE PIPE SLEEVE/CASING. AT PIPE CENTER LINE IE IN: 2501.25, 8-IN PVC (W) 5. IN EMERGENCY SITUATIONS AND WITH WRITTEN APPROVAL OF THE CITY ENGINEER BY OTHERS S OR THE INSPECTOR AS THE ENGINEER'S REPRESENTATIVE, REDWOOD SKIDS MAY IE IN: 2499.42, 30 IN PVC ( ) ( ) BE USED PER ISPWC SD-307,SECTION A-A. EXISTING GROUND ELEVATION IE OUT: 2499.32, 30-IN PVC (BY OTHERS) (N) 6. THE ANNULAR SPACE BETWEEN THE CARRIER PIPE AND CASING PIPE SHALL BE AT PIPE CENTER LINE IE OUT: 2501.16, 8-IN PVC (BY OTHERS) (E) FILLED IN ACCORDANCE WITH SECTIONS 308 AND 310. AN EXCEPTION MAY BE ALLOWED IF THE SLEEVE/CASING IS FOR NON-POTABLE SEPARATION �prIAL E REQUIREMENTS OR SLEEVING/CASING IS LESS THAN 10 FEET DEEP AND ABOVE 5s NG 2490 1 2490 SEASONAL HIGH GROUNDWATER.ALL EXCEPTIONS MUST BE APPROVED IN WRITING ���FG\S F BY THE CITY ENGINEER. N 568 N M Cl)� C\I � N N C'J J 06/15/2022 0 -0+50 0+00 1+00 � OF SOP `��ES REVISED JULY 2014 CITY OF MERIDIAN STANDARD DRAWING NO. s SPECIFICATIONS PIPE SLEEVE / CASING Project o.: 121201 TO THE IDAHO STANDARDS FOR SW2 Date of Issuance: 5.27.2022 PUBLIC WORKS CONSTRUCTION Project Milestone: Construction Documents Sanitary Sewer Plan & Profile - 05m01