CC - Staff Report for 6-28 STAFF REPORT E IDIANn-=-
COMMUNITY DEVELOPMENT DEPARTMENT A H O
HEARING 6/28/2022 Legend
DATE:
��W.ajec#L•oc a-u r
TO: Mayor&City Council _
FROM: Alan Tiefenbach
208-884-5533
SUBJECT: PP-H-2022-0006 :M I
Jump Creek South Preliminary Plat
LOCATION: The site is located at the northwest comer
of W. McMillian Rd. and N. Black Cat _
Rd. on Parcel SO428449525 in the SE '/4
of the SE 1/4 of section 28,Township 4N,
Range 1 W.
I. PROJECT DESCRIPTION
Request for a preliminary plat consisting of 20 single-family residential lots and 4 common lots on
3.57 acres of land in the R-8 zoning district,by Kent Brown.
II. SUMMARY OF REPORT
A. Project Summary
Description Details
Acreage 3.57 acres
Future Land Use Designation Medium Density Residential 3-8 du/acre
Existing Land Use(s) Vacant
Proposed Land Use(s) Single Family Residential
Lots(#and type;bldg./common) 20 building lots,and 4 common lots.
Phasing Plan(#of phases) 1 phase
Number of Residential Units(type 20
of units)
Density(gross&net) 5.6 du/ac
Open Space(acres,total Not required for properties less than 5 acres,but 15.73%of
[%]/buffer/qualified) open space was provided with the Jump Creek
Development Agreement,which governs this property.
Amenities Numerous amenities are included with the larger Jump
Creek development.
Physical Features(waterways, The West Tap Lateral traverses a small portion on the
hazards,flood plain,hillside) southeast
Neighborhood meeting date;#of December 21,2021,no attendees
attendees:
Page 1
Description Details
History(previous approvals) AZ-14-011,PP-14-013,DA instr. 2014-105206,FP-2022-
0004
B. Community Metrics
Description Details
Ada County Highway District
• Staff report(yes/no) No
Access(Arterial/Collectors/State "There are multiple points of access,but primary access
Hwy/Loca1)(Existing and Proposed) occurs via W.Daphne Street from N.Black Cat Rd.
Stub Street/Interconnectivity/Cross No stubs required.
Access
Existing Road Network N.Black Cat Rd and W.McMillian Rd,numerous internal
roads.
Existing Arterial Sidewalks/ There is an existing 5 ft.wide detached sidewalk and 25 ft.
Buffers wide buffer along N.Black Cat Rd.A 5 ft.wide sidewalk
and buffer along W.McMillian Rd.was approved with the
Jump Creek development but is not yet installed along the
southern perimeter of the subject property.
Proposed Road Improvements Required road improvements have already occurred with
Jump Creek No 1 through 6.
Fire Service
No comments,property will be serviced by Fire Station 7 when completed in 2023.
Police Service
• No comments
Wastewater
• Flow is committed
Water
• Distance to Water Services 0
• Pressure Zone M 1
• Water Quality No concerns
• Project Consistent with Yes
Water Master Plan
• Comments • Encase water main with steel sleeve when crossing the
west Tap Sublaterial piping or open channel.
• Water main sizes were not provided.All mains were
modeled as 8"
Page 2
+i-iii�rlf lilllli `- -
� ��IIIIII��HIII� 1111111111 �
111�1�I111
INIIIIIIIIIINI �_ �'''
IIIAl11All 11-f1A!111111 IIIAII
IIIIII��I�IINHI� �Illlll;ii�_ � 1111 1
IIIIIINNIII,.'
IIIII II I�WIIIIII NNuulllll 1111 1111
t i
I2� 19x M
millIri�N
p �H1111 �AI11<111��_ �r.MRir� +J11111 = `-d;j.- .
IY�Ih1ii IY�IIIII�UiiNlllll p �;: _ .: �i-.
.r1 : II minim N I-
f �Irdlii mill"
1111111 ���IIIIH11 IiGii1111g11
� : � hY11111 IYi111 �
111 ii� ii1Nw uw
INluuuuwl :_
_ � � F• _ _
1 � �i11�1�1�I1NH � 11115 NIRIN ■ �1111�1111!!i�.
111 IIIII 11 �r1111111 �i�l�s:l� a IIIIIINMI
i __ I51�1 � NNIIIIIIIII
!pr. 4y
■
11�gflll IIIII IIIIIN
� IIIII �HIII �N
p IIN�JNii�``��aa! ie� p 11 1NI.I S ��I11 oral
- _ I OEM
III. APPLICANT INFORMATION
A. Applicant Representative:
Kent Brown—3161 E. Springwood Dr,Meridian, ID 83642
B. Owner:
Corey Barton,Endurance Holdings— 1977 E. Overland Rd.,Meridian,ID 83642
IV. NOTICING
Planning& Zoning City Council
Posting Date Posting Date
Newspaper Notification 5/12/2022
Radius notification mailed to
properties within 300 feet 5/13/2022
Nextdoor posting 5/13/2022
Sign Posting 5/23/22
V. STAFF ANALYSIS
An annexation,preliminary plat, and development agreement was approved by City Council in
November of 2014 for the Jump Creek Subdivision,which included this property(AZ-14-011,PP-14-
013,DA instr.2014-105206). The approved project allowed 318 single family lots and two
multifamily lots on 85.9 acres. Six final plats totaling 308 total lots,including seven(7)multi-family
lots have been approved by the Council to date.
In May of 2021,the Planning Commission approved a conditional use permit for the first seven
fourplexes(Jump Creek North Fourplex CUP,H-2021-0018). During review of the project,it was
discovered that Jump Creek No 4.,the final plat intended for the fourplexes,was platted as individual
lots for each fourplex,whereas the preliminary plat approved one multi-family lot.Further,the
applicant intends to subdivide the other multi-family lot approved with the preliminary plat in the
same manner,which exceeds the number of lots approved with the original Jump Creek preliminary
plat.
Staff discussed this issue with the applicant,and the agreed upon solution was that the applicant
would move forward with Phase 6 for 44 single family lots(approved by City Council on May 18,
2022)and Phase 7 for 12 fourplex lots. The remaining 3.57 acres(the subject property,which was
initially anticipated as Jump Creek No. 8)will be platted as 20 additional lots as a new preliminary
plat. It is important to note that although the total number of lots is more than was approved
with the initial Jump Creek Subdivision,the total number of units(318 single family and 19
fourplexes) and configuration is the same as what was approved.
Page 4
A. Future Land Use Map Designation(https://www.meridiancity.org/compplan)
The property is designated" Medium Density Residential" (MDR)on the future land use map.
The MDR designation allows smaller lots for residential purposes within City limits.Uses may
include single-family homes at densities of 3 to 8 dwelling units per acre.
The subject property was initially approved for 318 single family lot and 19 fourplexes on 85.9
acres,which is a gross density of 4.59 dwelling units per acre. Although the number of lots will
increase by 20,the number of units and density will remain the same. This is consistent with the
MDR land use designation.
B. Zoning:
The subject property is zoned R-8. The R-8 zoning district requires a minimum lot size of 4,000
sq. ft. and minimum street frontage of 40 ft. The preliminary plat shows the smallest lot being
5,000 sq. ft. and minimum street frontages of 50 ft.
C. Comprehensive Plan Policies(https:llwww.meridianciU.or /�compplan):
• Encourage diverse housing options suitable for various income levels,household sizes,and
lifestyle preferences. (2.01.01)
This project proposes 20 additional single family units in a development of 318 single family
units and 72 fourplex units. This increases the diversity in housing and meets the needs,
preferences, and financial capabilities of Meridian's present and future residents.
• Encourage a variety of housing types that meet the needs,preferences, and financial capabilities
of Meridian's present and future residents. (2.01.02D)
The applicant is developing a mixed housing residential development consisting of primarily
medium density single-family and multi family units, consistent with this goal. The multifamily
developments are being evaluated with future conditional use permit applications.
• Encourage the development of high quality, dense residential and mixed use areas near in and
around Downtown,near employment, large shopping centers,public open spaces and parks, and
along major transportation corridors,as shown on the Future Land Use Map.
The development provides housing opportunities in close proximity to a proposed Walmart and
an existing shopping center at the northeast corner of Chinden Boulevard and Linder Road.
Future employment uses are planned a mile east of the proposed subdivision along the west side
ofN. Ten Mile Road.
• Require urban infrastructure be provided for all new developments, including curb and gutter,
sidewalks,water and sewer utilities. (3.03.03F)
City services were required to be extended to the properties upon development in accord with
UDC 11-3A-21. Infrastructure was constructed with phases 1, 2, and 3. No additional
infrastructure is required with this proposal.
Page 5
• Permit new development only where it can be adequately served by critical public facilities and
urban services at the time of final approval, and in accord with any adopted levels of service for
public facilities and services. (3.03.03F)
This proposal was referred to fire and police services as well as WASD. There were no additional
comments beyond what were listed with the preliminary plat and final plat.
• Require open space areas within all residential development. (6.01.O1A)
The development agreement approved with the annexation required 15%total open space, and
15.3%was provided with the total development. The lot size, area and open space configuration
included with this preliminary plat matches what was approved with the initial approval.
• With new subdivision plats,require the design and construction of pathway connections, easy
pedestrian and bicycle access to parks, safe routes to schools, and the incorporation of usable
open space with quality amenities."(2.02.01A)
The proposed plat depicts 5 ft. wide detached sidewalks on both sides of roads internal to the
subdivision.Multiple pedestrian connections were approved throughout the initial Jump Creek
development including several connections into the Oaks North project to the east.A 5 ft. wide
detached sidewalk and 25 ft. wide buffer has already been constructed along N. Black Cat Rd.A
landscape buffer and 5 ft. wide detached sidewalk exists to the west of this subject property; the
applicant will be required to complete these improvements as a condition of approval of this
preliminary plat.
D. Existing Structures/Site Improvements:
The property is presently vacant.
E Proposed Use Analysis:
Single-family dwellings are listed as a principal permitted use in the R-8 zoning districts in UDC
Table 11-2A-2.
F. Dimensional Standards(UDC 11-2):
The preliminary plat and future development is required to comply with the dimensional
standards listed in UDC Table 11-2A-6 for the R-8 district.All proposed lots and public streets
appear to meet UDC dimensional standards per the submitted preliminary plat. This includes
minimum lot size of 4,000 sq. ft., and required street frontages of at least 40 ft. Development of
the subdivision is required to comply with the subdivision design and improvement standards
listed in UDC 11-6C-3.
UDC 11-6C-3-regulates block lengths for residential subdivisions. Staff has reviewed the
submitted plat for conformance with these regulations. The intent of this section of code is to
ensure block lengths do not exceed 750 ft,although there is the allowance of an increase in block
length to 1,000 feet if a pedestrian connection is provided.No block length exceeds 750 ft.
There is one common driveway serving Lots 30 and 31 of Block 20. This driveway connects to
the future fourplexes in Jump Creek Filing 7 and will serve as secondary emergency access.As
this would be a driveway and not a street, staff has added a condition that the common driveway
shall be gated from the multifamily portion of the site(Filing 7). Such gate shall meet all
requirements of Meridian Fire but shall not obstruct pedestrian access.
Page 6
G. Access(UDC 11-3A-3):
All accesses were previously approved with the Jump Creek preliminary plat. ACED has
responded that they had reviewed and approved the Jump Creek Subdivision in 2014 and the site-
specific conditions of approval for Jump Creek South apply to this project.
H. Parking(UDC 11-3C):
Off-street parking is required to be provided in accord with the standards listed in UDC Table 11-
3C-6 for single-family attached dwellings based on the number of bedrooms per unit. Future
development should comply with these standards.
I. Pathways ( UDC 11-3A-8):
There is an existing 5' wide detached sidewalk along N. Black Cat Rd,at the eastern perimeter of
the subject property as well as a 5 ft. detached sidewalk along W. McMillian Rd west of the
subject property. The applicant will be required to complete this sidewalk with this project.
Multiple pedestrian connections were approved throughout the initial Jump Creek development
including several connections into the Oaks North project to the east.No additional pathways are
required or proposed with this plat. All of the pedestrian connections must comply with the
standards set forth in UDC 11-3A-8 and UDC 11-3B-12.
Sidewalks(UDC 11-3A-17):
Five-foot detached sidewalks are proposed along internal streets in accord with the standards
listed in UDC 11-3A-17.
K. Landscaping(UDC 11-3B):
UDC 11-2A-6 requires a 25 ft.wide buffers along arterial roads (W.McMillian Rd.). This buffer
is indicated on the landscape plan. All pathways and micro-pathways meet the requirements of
UDC 11-3B including landscape strips of at least 5 ft. in width on either side and one tree per 100
linear feet. A drainage facility is indicated in Lot 15,Block 20;this lot shall be landscaped as
required per UDC 11-3B-11.
The landscape plan does not indicate whether there are healthy existing trees meeting the
preservation requirements on the property. With the submittal of the final plat the applicant
should submit a revised landscape plan that details any mitigation plan outlined by the developer
and the City Arborist.
L. Qualified Open Space (UDC I1-3G):
The subject property is 3.57 acres,which would exempt it from the common open space
requirements of UDC 11-3G. However,this property is included in the Jump Creek Development
Agreement which requires 15.73%open space, including numerous drainage lots, 50%of the
arterial street buffers, collector street buffers,micropath lots, and passive open space in various
sizes. The preliminary plat as proposed matches what was approved with the original Jump Creek
Preliminary Plat in regard to lot size, configuration, and open space.
M. Qualified Site Amenities (UDC 11-3G):
During the approval process for the entire Jump Creek Subdivision(which included the subject
property), approved amenities included three tot lots,an integrated pathway system, extension of
the Meridian Pathway system and 5%additional open space. Most amenities have already been
constructed with the previous phases and two additional amenities were required with the
conditional use permit that was approved for the first multifamily phase.As this current
Page 7
preliminary plat is part of the approved Jump Creek development agreement and is proposed with
the same design and number of lots as what was approved, additional amenities are required.
N. Waterways (UDC 11-3A-6):
The West Tap Sublateral clips the northeastern corner of Lot 31, Block 20. Per UDC, all
irrigation ditches,laterals or canals, exclusive of natural waterways and waterways being used as
amenities,which intersect,cross or lie within the area being subdivided should be covered.
O. Fencing(UDC 11-3A-6, 11-3A-7):
The landscape plan includes a fencing plan. The plan includes 6 ft.high vinyl fencing along the
western periphery of the site, along the side of residential lots adjacent to internal roads, and rear
of the residential lots adjacent to W.McMillan Rd(but outside of the required landscape buffers).
4 ft.high vinyl fencing is shown along at least one side of common open spaces and both sides of
pathways and micro-pathways. The fencing appears to meet the requirements of 11-3A-6 and 11-
3A-7.
P. Utilities (UDC 11-3A-21):
Public services are available to accommodate the proposed development and most utilities have
already been installed.
Q. Building Elevations(UDC 11-3A-19 I Architectural Standards Manual):
Building elevations were submitted and approved with the initial annexation and development
agreement. The Applicant submitted the same approved elevations. Per the approved Jump Creek
Development Agreement, all homes adjacent to McMillan Road shall incorporate a mix of
materials,windows and decorative trim,pop -outs, covered porches and two variations in the roof
lines to provide articulation and modulation to the side and rear facades that face the arterial and
collector streets.
VI. DECISION
A. Staff:
1. Staff recommends approval of the requested preliminary plat with the conditions noted in
Section VIII.per the Findings in Section IX.
Page 8
B. The Meridian Planning&Zoning Commission heard this item on June 2,2022.At the public
hearing.the Commission moved to approve the subject preliminary plat request.
1. Summary of the Commission public hearing:
a. In favor: Kent Brown
b. In opposition:None
c. Commenting: Kent Brown
d. Written testimony: None
e. Staff presenting application: Alan Tiefenbach
f Other Staff commenting on application:None
2. Key issue(s)of public testimony:
a. None
3. Key issue(s)of discussion by Commission:
a. None
4. Commission change(s)to Staff recommendation:
a. None
Page 9
VII. EXHIBITS
A. Approved Preliminary Plat(date: 05/30/2014)
�.
• irr _
y of
rt� I IN��ill V411 N}II�
1 Q 4uIG.F �as
— all ru r.c �
u�. v". rw s•. . il. t,� .ti a..� s.. ..0 �
I
I
{ s �o-o�
• —_� a ulnl+lul
/j
n
IA9, 2 aw +p• � L`2�
nmal+I I n . ......... ..........
I I I G Il t
B. "Proposed"Jump Creek South Preliminary Plat(date: 9/24/2021)
~ �_r
n-
W.RIVA:CAPRI ST- -
w
7--
I'f;
a
-
I
W
C. Proposed Landscape Plan(Date:November 11/2/2020)
-H 6LIMITS LANDSCAPE
nu -__ III � i ...` I I ��.� •�• �
I
Pi E6LIMf �I 1yI
L Q PLANT SCH
.L1 "r .T- I
w 1'
•__ W.JIMP CPE&!dk.
I I�
---- -�* —__ 7—
IL --y--4-
----
>i:,.::'
IS
m. �:•.� --.ice .. ..
NOSCAPE PLAN-AREA ONE o W
Page 11
1 I' PHASE @L mm, .•'f` I'\-' 7. �rP YA3EBLJMITS
I 1 ' J
PL
In
—� Tlx
;rf S.
l
� 41iCIlME-'.(S.9�EET L7.11 s:•. ��' __� —__ w
III!
I'-
1 I
t N❑SCAPE PLAN -AREA TWO
e
W.Juw CRCK DR.
r
__ _—__�__�' fir: ;' .•��_�__� SNTC�01rf-SFF 51i 0,11
' I .
• it —i I`l�_�_ kNM IFF.-9F.E SeF.FEI 11,1j I ��� ��— _
L '
it
- I •aar1��
4
- 13J i
T�-
_�J4. --441
a
41
Oba
......- N_ Ivlcivii. =`�l RCA-'•.� � •
' PHlS:2 i LJFFI 73�
+I tiL-ANDSCAPE PLAN - AREA THREE
Page 12
AR
e � I iIh1G[P�•S��IEET L1,19
-
I
-
:i I �
TIT
UOI
F a'
ROAD
W.MGMILLAN RCLAO
4ASE 61lNITS :a PRASE 5 ukArm
a .4-11 ANrP.grAPF PI AN -ARFA FrM IR
Page 13
VIII. AGENCY COMMENTS & CONDITIONS
A. PLANNING DIVISION
1. The Preliminary Plat included in Section VI, is approved with the following revisions:
a. Add date to the plat.
b. Revise Preliminary Plat name to read"Jump Creek South Subdivision.
2. The Landscape Plan included in Section VI, dated 11/2/2020,is approved with the addition
that the landscape plan shall indicate whether there are healthy existing trees meeting the
preservation requirements on the property.
3. Unimproved right of way along W. McMillan Rd shall be improved as required per UDC 11-
3B-7C.5
4. The common driveway serving Lots 30 and 31 of Block 20 shall be gated from the
multifamily portion of the development(Filing 7). Such gate shall meet all requirements of
Meridian Fire but shall not obstruct pedestrian access.A common driveway exhibit meeting
the requirements of UDC 11-6C-3-D shall be provided at time of final plat.
5. The applicant is to meet all terms of the approved annexation(AZ-14-011) and development
agreement(Instrument#2014-105206) for this development.
6. The applicant shall comply with all provisions of 11-3A-3 with regard to access to streets.
7. The development shall comply with standards and installation for landscaping as set forth in
UDC 11-313-5 and maintenance thereof as set forth in UDC 11-3B-13.
8. All homes adjacent to McMillan Road shall incorporate a mix of materials,windows and
decorative trim,pop -outs, covered porches and two variations in the roof lines to provide
articulation and modulation to the side and rear facades that face the arterial and collector
streets per Development Agreement Instr.2014-105206.
9. Pathway and adjoining fencings and landscaping shall be constructed consistent with the
standards as set forth in UDC 11-3A-7A7, 11-3A-8 and 11-3B-12C.
10. The applicant shall construct all proposed fencing and/or any fencing required by the UDC,
consistent with the standards as set forth in UDC 11-3A-7 and 11-3A-6B, as applicable.
11. The development shall comply with all subdivision design and improvement standards as set
forth in UDC 11-6C-3,including but not limited to driveways,easements,blocks, street
buffers,and mailbox placement.
12. Off-street parking is required to be provided in accord with the standards listed in UDC Table
11-3C-6 for single-family attached dwellings based on the number of bedrooms per unit.
13. All ditches shall comply with the provisions for irrigation ditches, laterals,canals and/or
drainage courses, as set forth in UDC 11-3A-6 unless waived by City Council.
14. The Applicant shall have a maximum of two (2)years to obtain City Engineer's signature on
a final plat in accord with UDC 11-613-7.
15. The Applicant shall comply with all conditions of ACHD.
Page 14
B. PUBLIC WORKS DEPARTMENT
Site Specific Conditions of Approval
1. The geotechnical investigative report prepared by SITE Consulting,LLC indicates some very
specific construction considerations. The applicant shall be responsible for the adherence of these
recommendations to help ensure that groundwater does not become a problem within crawlspaces
of homes.
2. Encase water main with steel sleeve when crossing the West Tap Sublateral piping or open
channel.
3. Water main sizes were not provided, all mains were modeled at 8' inch diameter.
4. An access roadway to manhole SSMH C3 must meet City standards.
General Conditions of Approval
1. Applicant shall coordinate water and sewer main size and routing with the Public Works
Department, and execute standard forms of easements for any mains that are required to provide
service outside of a public right-of-way. Minimum cover over sewer mains is three feet,if cover
from top of pipe to sub-grade is less than three feet than alternate materials shall be used in
conformance of City of Meridian Public Works Departments Standard Specifications.
2. Per Meridian City Code(MCC),the applicant shall be responsible to install sewer and water
mains to and through this development. Applicant may be eligible for a reimbursement
agreement for infrastructure enhancement per MCC 8-6-5.
3. The applicant shall provide easement(s)for all public water/sewer mains outside of public right of
way(include all water services and hydrants). The easement widths shall be 20-feet wide for a
single utility,or 30-feet wide for two. The easements shall not be dedicated via the plat,but
rather dedicated outside the plat process using the City of Meridian's standard forms. The
easement shall be graphically depicted on the plat for reference purposes. Submit an executed
easement(on the form available from Public Works),a legal description prepared by an Idaho
Licensed Professional Land Surveyor,which must include the area of the easement(marked
EXHIBIT A)and an 81/2"x I I"map with bearings and distances(marked EXHIBIT B) for
review. Both exhibits must be sealed, signed and dated by a Professional Land Surveyor.DO
NOT RECORD. Add a note to the plat referencing this document. All easements must be
submitted,reviewed, and approved prior to development plan approval.
4. The City of Meridian requires that pressurized irrigation systems be supplied by a year-round
source of water(MCC 9-1-28.C). The applicant should be required to use any existing surface or
well water for the primary source. If a surface or well source is not available, a single-point
connection to the culinary water system shall be required. If a single-point connection is utilized,
the developer will be responsible for the payment of assessments for the common areas prior to
prior to receiving development plan approval.
5. All existing structures that are required to be removed shall be prior to signature on the final plat
by the City Engineer. Any structures that are allowed to remain shall be subject to evaluation and
possible reassignment of street addressing to be in compliance with MCC.
Page 15
6. All irrigation ditches,canals, laterals, or drains, exclusive of natural waterways,intersecting,
crossing or laying adjacent and contiguous to the area being subdivided shall be addressed per
UDC 11-3A-6. In performing such work,the applicant shall comply with Idaho Code 42-1207
and any other applicable law or regulation.
7. Any wells that will not continue to be used must be properly abandoned according to Idaho Well
Construction Standards Rules administered by the Idaho Department of Water Resources. The
Developer's Engineer shall provide a statement addressing whether there are any existing wells in
the development, and if so,how they will continue to be used, or provide record of their
abandonment.
8. Any existing septic systems within this project shall be removed from service per City Ordinance
Section 9-1-4 and 9 4 8. Contact Central District Health for abandonment procedures and
inspections(208)375-5211.
9. Street signs are to be in place, sanitary sewer and water system shall be approved and activated,
road base approved by the Ada County Highway District and the Final Plat for this subdivision
shall be recorded,prior to applying for building permits.
10. A letter of credit or cash surety in the amount of 110%will be required for all uncompleted
fencing, landscaping, amenities, etc.,prior to signature on the final plat.
11. All improvements related to public life, safety and health shall be completed prior to occupancy
of the structures.Where approved by the City Engineer, an owner may post a performance surety
for such improvements in order to obtain City Engineer signature on the final plat as set forth in
UDC 11-5C-3B.
12. Applicant shall be required to pay Public Works development plan review, and construction
inspection fees, as determined during the plan review process,prior to the issuance of a plan
approval letter.
13. It shall be the responsibility of the applicant to ensure that all development features comply with
the Americans with Disabilities Act and the Fair Housing Act.
14. Applicant shall be responsible for application and compliance with any Section 404 Permitting
that may be required by the Army Corps of Engineers.
15. Developer shall coordinate mailbox locations with the Meridian Post Office.
16. Compaction test results shall be submitted to the Meridian Building Department for all building
pads receiving engineered backfill,where footing would sit atop fill material.
17. The design engineer shall be required to certify that the street centerline elevations are set a
minimum of 3-feet above the highest established peak groundwater elevation. This is to ensure
that the bottom elevation of the crawl spaces of homes is at least 1-foot above.
18. The applicants design engineer shall be responsible for inspection of all irrigation and/or
drainage facility within this project that do not fall under the jurisdiction of an irrigation district
or ACHD. The design engineer shall provide certification that the facilities have been installed in
Page 16
accordance with the approved design plans. This certification will be required before a certificate
of occupancy is issued for any structures within the project.
19. At the completion of the project,the applicant shall be responsible to submit record drawings per
the City of Meridian AutoCAD standards. These record drawings must be received and approved
prior to the issuance of a certification of occupancy for any structures within the project.
20. A street light plan will need to be included in the civil construction plans. Street light plan
requirements are listed in section 6-5 of the Improvement Standards for Street Lighting. A copy
of the standards can be found at http://www.meridiancioy.oMlpublic_works.aspx?id=272.
21. The City of Meridian requires that the owner post to the City a performance surety in the amount
of 125%of the total construction cost for all incomplete sewer,water and reuse infrastructure
prior to final plat signature. This surety will be verified by a line item cost estimate provided by
the owner to the City. The surety can be posted in the form of an irrevocable letter of credit,cash
deposit or bond.Applicant must file an application for surety,which can be found on the
Community Development Department website. Please contact Land Development Service for
more information at 887-2211.
22. The City of Meridian requires that the owner post to the City a warranty surety in the amount of
20%of the total construction cost for all completed sewer,water and reuse infrastructure for
duration of two years. This surety will be verified by a line item cost estimate provided by the
owner to the City. The surety can be posted in the form of an irrevocable letter of credit, cash
deposit or bond.Applicant must file an application for surety,which can be found on the
Community Development Department website. Please contact Land Development Service for
more information at 887-2211.
C. ACHD
https://weblink.meridianciV.orglWebLink/Doc View.aspx?id=262186&dbid=0&repo=MeridianC
hty
D. DEPARTMENT OF ENVIRONMENTAL QUALITY
https://weblink.meridiancily.org/WebLinkIDocView.aspx?id=261512&dbid=0&repo=MeridianC
iv
Page 17
IX. FINDINGS
A. PRELIMINARY PLAT(UDC 11-6B-6)
In consideration of a preliminary plat,combined preliminary and final plat, or short plat,the
decision-making body shall make the following findings: (Ord. 05-1170, 8-30-2005, eff. 9-15-
2005)
1. The plat is in conformance with the comprehensive plan and is consistent with this unified
development code; (Ord. 08-1372, 7-8-2008, eff. 7-8-2008)
Commission finds the proposed plat is generally in conformance with the UDC if the
Applicant complies with the conditions of approval in Section VII.
2. Public services are available or can be made available and are adequate to accommodate the
proposed development;
Commission finds public services can be made available to the subject property and will be
adequate to accommodate the proposed development.
3. The plat is in conformance with scheduled public improvements in accord with the city's
capital improvement program;
Commission finds the proposed plat is in substantial conformance with scheduled public
improvements in accord with the City's CIP.
4. There is public financial capability of supporting services for the proposed development;
Commission finds there is public financial capability of supporting services for the proposed
development.
5. The development will not be detrimental to the public health, safety or general welfare; and
Commission finds the proposed development will not be detrimental to the public health,
safety or general welfare.
6. The development preserves significant natural, scenic or historic features. (Ord. 05-1170, 8-
30-2005, eff. 9-15-2005)
The West Tap Sublateral clips the northeastern portion of the property, but there are no
natural features. According to the landscape plan, there are no healthy trees onsite meeting
the requirements for preservation.
Page 18