Loading...
CC - Signage and Street Light Plan/ � I \ \ \ N N/CKORI, wAV \ \ Know what's below. Call before you dig F NOTE: WORK CONTAINED WITHIN THESE PLANS SHALL NOT COMMENCE UNTIL AN ENCROACHMENT PERMIT AND/OR A GRADING PERMIT HAS BEEN ISSUED. DRAWING STATUS: FOR AGENCY REVIEW MARK BY ENGINEER REVISIONS SEAL -ENGINEER Q�OF ISTfgF.O No. 17011 T DATE 9y�pFW FF COUNTY • PLANNING BLAINE A. WOMER •SURVEYING CIVIL CIVIL ENGINEERING ENGINEERING *PUBLIC WORKS Boise, ID 83706, 4355 M Emerald Street, Suite 145 • 1-208-593-7555 SEE SHEET C 1.0 SCALE; H V; 0 20 40 60 ® KEYNOTES 1. INSTALL TYPE 2 STREET LIGHT POLE WITH LUMINAIRE IN ACCORDANCE WITH THE CITY OF MERIDIAN, DEPARTMENT OF PUBLIC WORKS IMPROVEMENT STANDARDS FOR STREET LIGHTING, AND THE MOST CURRENT CITY OF MERIDIAN SUPPLEMENTAL SPECIFICATIONS AND DRAWINGS TO THE ISPWC. TYPE 2 STREET LIGHT POLES SHALL BE 25' NOMINAL MOUNTING HEIGHT, SQUARE STEEL WITH BRONZE POLYESTER COATING AND CONFORM TO THE SUPPLEMENTAL SPECIFICATIONS. LUMINAIRES SHALL BE LED FIXTURES THAT ARE ON THE APPROVED FIXTURE LIST (SEE APPROVED LED FIXTURE LIST FOR STREET LIGHTING), OR HAVE BEEN PRE -APPROVED IN WRITING BY THE CITY'S TRANSPORTATION AND UTILITY COORDINATOR, 2. EXISTING STREET LIGHT. 3. INSTALL 12"x18" "NO PARKING FIRE LANE" SIGN TYPE "D" PER THE MOST CURRENT EDITION OF THE IFC APPENDIX D, SECTIONS D103.5 AND D103.6.1. 4. INSTALL STREET DESIGNATION SIGN PER CITY OF MERIDIAN REQUIREMENTS. 5. MAILBOX CLUSTER LOCATION. SHEET NOTES A. CONTRACTOR TO VERIFY STREET LIGHT LOCATIONS WITH CITY OF MERIDIAN AND ACHD PRIOR TO INSTALLATION AND NOTIFY ENGINEER IF SAFETY HAZARDS OR UTILITY CONFLICTS EXIST. B. THE MAXIMUM SPACING FOR TYPE II FIXTURES ALONG LOCAL ROADS (33 FT OR LESS) IS 260'. C. THE MAXIMUM SPACING FOR TYPE I FIXTURES ALONG 5-LANE RESIDENTIAL MOBILITY ARTERIALS IS 300' STAGGERED. D. STREET LIGHTS SHALL BE OWNED/MAINTAINED BY THE CITY OF MERIDIAN. E. SERVICE - ALL STREET LIGHTS SHALL HAVE UNDERGROUND ELECTRICAL SERVICES PROVIDED. SERVICE VOLTAGE SHALL BE 120 OR 240 VOLTS ONLY. CONTRACTOR SHALL DETERMINE CONDUIT SLEEVE LOCATIONS, SIZES, AND AMOUNT REQUIRED AT ALL UTILITY AND PAVEMENT CROSSINGS. F. METERING - CONTRACTOR SHALL COORDINATE METER LOCATIONS WITH IDAHO POWER AND CITY OF MERIDIAN. WHERE A METERED SYSTEM IS REQUIRED, NEW DEVELOPMENTS SHALL INSTALL CONDUIT WITH ONE NO. 10 STRANDED PULL WIRE FROM THE LAST LIGHT ON EACH END OF THE SYSTEM TO THE ADJACENT PROPERTY LINE ON A STUBBED STREET, WHERE THE ADJACENT PROPERTY HAS NO EXISTING STREET LIGHT SYSTEM. THIS WILL ALLOW FOR THE CONTINUATION OF THE STREET LIGHTS WHEN THE ADJACENT PROPERTY IS DEVELOPED. SHEET NO, CITY OF MERIDIAN, ID C1.3 WOODCREST TOWNHOMES SUBDIVISION GENERAL IMPROVEMENT PLANS FILE NO. SIGNAGE AND STREET LIGHT PLAN N1420004