Z - Final Plat Approval City Council 2-22 FP-2022-0003 East Ridge No. 3 Item#8.
STAFF REPORT E IDIANn-=-
COMMUNITY DEVELOPMENT DEPARTMENT A H O
HEARING 2/22/2022 Legend U
DATE: x
TO: Mayor&City Council
FROM: Alan Tiefenbach,Associate Planner
208-489-0573 :
SUBJECT: FP-2022-0003 �J
Impressive East Ridge No. 3
LOCATION: North side of E. Lake Hazel Rd.between .r -
S. Locust Grove Rd. and S. Eagle Rd. in `t ,
the southeast '/4 of Section 32,Township
3N.,Range 1 E. rf,
+ 1 I
{ 1 I
5
I
I. PROJECT DESCRIPTION
Final plat consisting of 55 buildable lots, 6 common lots, 1 private street and 3 common drive lots on
8.69 acres of land in the R-15 zoning district.NOTE: The Director approved a private street
application which includes the private streets for the entire R-15 portion of the development with
Impressive East Ridge No 2.
II. APPLICANT INFORMATION
A. Applicant/Representative
Sophia Durham, The Conger Group—4824 W. Fairview Ave.,Boise ID 83706
B. Owner:
C4 Land LLC—PO Box 1610,Eagle ID 83616
III. STAFF ANALYSIS
The annexation,preliminary plat and development agreement for this development was approved by
City Council on November 2017 as the East Ridge Estates Subdivision(H-2017-0129). The approved
project allows the construction of a residential subdivision consisting of one hundred thirty-nine (139)
residential lots and seven(7) common lots. The Final Plat for Phase One was approved by the
Council on July 17, 2019. The Final Plat for Phase Two was approved by the Council on March 2,
2021.
In November of 2020,the City Council approved an amendment to the development agreement(H-
2020-0096). This was due to a request of the applicant to make changes to the configuration of the
Page 1
Page 109
Item#8.
plat and landscape plan,replace a required clubhouse amenity with a dog park, outdoor ramada
(shade structure), and water feature, and eliminate a number of requirements that were originally
established to address concerns of an adjacent property owner to the west who has since sold their
property. The ramada and water feature are being constructed with the second phase.
Gated private streets are proposed with Phase Three. UDC 11-3F-4 lists the design standards which
are required for private streets. The preliminary plat proposed common driveways off private streets,
whereas this is prohibited by UDC 11-3F-4-6. Alternative compliance is allowed from the design and
construction standards, and at the time of the preliminary plat the applicant was granted alternative
compliance to allow the common driveways. It should be noted the road configuration with the
preliminary plat proposed numerous common driveways off private streets,whereas the current
proposal only includes three common drives. The applicant submitted private street sections that
comply with all remaining requirements of UDC 11-3F4. A complete maintenance agreement that
met the requirements of UDC 11-3F-3B.4 was submitted with reviewed and approved with the second
phase.
Staff has reviewed the proposed final plat for substantial compliance with the approved preliminary
plat and modified development agreement in accord with the requirements listed in UDC 11-6B-3C.2.
Because the final plat matches what was approved with the modified development agreement,does
not increase the number of building lots and contains the same amount of qualified open space, Staff
finds the proposed final plat is in substantial compliance with the approved preliminary plat as
required.
IV. DECISION
Staff recommends approval of the proposed final plat within the conditions noted in Section VI of
this report.
Page 2
Page 110
Item#8.
V. EXHIBITS
A. Preliminary Plat as Approved with Amended DA(date: 10/23/2020)
1_ - -- ---- -- - -- ----1— - - -L
1 I = I
•v '1 '� 'I f9 !, r 4i 7 1 Y14 W 17 �N 9 w 7: 71 a. 'j
r r F i f
I .3 F I .•v
- ~ 03 = _ TO r I' w ,pT 01 IW TM r _ +c-1 ic_ i.:i ,�I
1 �
-' .z �'^ '«—'ar yiru� f _•"r r,r
T: .� I 11 »sr f•
s le` w
1 _ f •+� f
14
.PA .Re 17
- sr
I SS -� a3 I 1r 13
.. _LL_
,ti r a•
"r F ' v r ' F i sl
Page 3
Page111
B. Final Plat(date: 1/2022)
5 99'57;r E V 940,37-
�, �°� 3`��I L �*ir`-�_� �-`�{ -- . a -T
87 ,
xw
14 LANE PVT
Tm
�T
—UAV-
."I
cw ------
xfary tea'
I A" _
faw jy Ial '01 jv ------- ----"--U-I-C-K--I----
of
L IL -,r-1 1 1
-WAU 's, 214 W— ---
�aw- 46 ICI
iB 111b�K 4 =•r PUM-TA91 P. Y7
70 Al
N,
49 LTNtTARLE-
MR,
61 HE i4my.— Zf t
17P
W.S.M
T 'fil3.37.,
-J ------------—
----—----— -
u pf
---------—-— -
14 I
85
Sai'FAl'F Ida v__j 1-N
J FCENEJ
----------
-97
-,LVL.- 11574 11574
I E. FERCHAN
rffi
w irz LAMB WVT)
------------
Ir".110.1 go. WEREN=
RU M.j, W,
LL-2
Page 4
Item#8.
C. Landscape Plan(date: 10/1/2021)
I'; } 13,
,a
I. 1In lu 10} loo
III 95
II . +
I
MATCHLINEL r.w.11a<I.,Rv�.r _ ly 96
MATCHLINE L2
¢1 _
MATCHLINE Li
MATCHLINE L2 _
iz ns
L- _s—
I
� I
� I
SS �I
.i fi7 T I I
I
'Mn'.r.lc.:x filr.a. F I
{�.i ILRIFE'illt �3
ij,
-
ly `f _
I I =
I I I
1 y fi5
I' S5 FI
I ' f
I '
Ilxlliil.11l II is{..I..
I I fl III' III• �I
" •II 55 I'I
_ i 1 I'V-
y �III 11
A (rvr) —
I
III I
� I
fil
I
I
I ca.rnn�.�lraNc xi.I
I t
l
I [ e
E.LAM ffiM RIM u
Page 5
Page 113
Item#8.
D. Open Space Exhibit(date: 10/23/2020)
- - -- -- -- -- L-
I
I
I I
r
A ;F
� I �
F
Page 6
Page 114
Item#8.
E. Common Drive Exhibit(date: 1/24/2021)
vk
LA
J
Ic
D
S
———LOT 53 TAKES ACCESS FROM I.:.. .
OTM05T LN. DRIVEWAY LOGATEa
ON NORTH SIDE OF LOT.
I � 63
J �
I �
L-- ------------ k EBERGHAN LN tPV7?
LA
62
I
I '..:.
V1 20.M' FRONT �5.�C}' LSPC y
—————————SETBACK TYP. BUFFER
I �
I
I 12.00' REAR I 59
SETBACK TYP.
20_00' COMMON
DRIVE
I 51 I LOT 59 TAKES ACCnS FROM
BERGHAN LN. DRIVEWAY LOCATED
ON EAST SIDE OF LOT-
BLOCK � I I
I I � I
-- J
N
W---------------
ua COMMON DRIVE ANO LANDSCAPE �
BUFFER TO BE OWNED AND o m
a MAINTAINED BY HGA. LOT 54 R�
UIDNTAIN5 A PERPETUAL r u'
INGRESS/EGRESS EASEVENT
Page 7
Page 115
Item#8.
LOT 77 TAKES ACCESS FROM
BLOCK 4 GALLEON LN. DRIVEWAY LOCATED
SETBACK ITYP.�{ o ON EAST SIDE OF LOT,
04
I _"
I I I I I
I I I I I
10.00• SETBACK 75 76 _ 78
UTILITY ESMT 77
Ip� I I
o Iv�
�W
COMMON DRIVE AND LANDSCAPE 0: a"
BUFFER TO BE OWNED AND o ��
MAINTAINED BY HOA. LOT 74 o I/
CONTAINS A PERPETUAL N
INGRESS/EGRESS EASEMENT
E GALLEON LN(FVT1
74
———————————— ——
12.00' REAR a
SETBACK TYP.
� f
73
al
LOT 73 TAKES ACCESS FROM z
UTMOST LN. DRIVEWAY LOCATED
ON SOUTH S1DE OF LOT.
� 710
r
LOT 90 TAKES ACCESS FROM BLOCK 4
GALLEON LN. DRIVEWAY LOCATED
ON WEST SIDE OF LOT. 5.00' SIDE S
SETBACK TYP.
f
10.00' SETBAC
UTIIJTY ESMT
89 90 91 92
I
I i 14 I i z I
N r
BUF
MAID
C0
E GALLEON LN(PVT) INGI
.� 03
-- -----------I
U
R EAR
SETBACK TYP.
I S q m 44
� I
LOT 94 TAKES ACCESS FROM
z _•�aa KIWANO LN. DRIVEWAY LOCATED
p ON SOUTH SIDE OF LOT.
99 98 1 I
rage a
Page 116
Item#8.
Emergency Access Exhibit(date: 1/5/2021)
E
E- E DI R T
1 Lvehide
ary
[h.0
s
-gr
I I I I I I I I I I I I I I I I I r -
1I
� _ _ _ _411
x -- - izf y ---------,
sc T
I I e
r -
s n
�--------� 7'
i.s.M�r" I L I
i l I
14 I I I
EC
i .a L--------J L qE;' r R I
I r--------� r--------i
---------
I
T. ..,.R-,w. � u ao /1
.-
----------
I r • .
I I I I I TO I ti
r--------, PnTpavy sire
II - II II II II II ,
P.T
I I I I I I I I I � �
I I l I I I
I I _
I I
I I
EE E x'R aoun,nwll^ o [
o �
AL'EC Erlc•1: i. A:f°trE lzJ al�.�
Page 9
Page117
Item#8.
F. Amenity Details (date: 1/5/2021)
a
pis as ss a� m x9 zs xr m xs
za za
2l
E2'EMd LANEIPRIVA7E1 -
'' as
,7
a.
J
} 3+ s
37 l
4'i
g —
as 3s
N Ramada o r Water q:.. ,•
�F Shea Featlhe
43 39 6 ✓ i -- _
42 40
EB CRAM LSNF MftJVATZ
lu
i rb
M-81 Water Feature
mail
4
'3
S
r
1 {
F --
Page 10
Page 118
Item#8.
VI. CITY/AGENCY COMMENTS & CONDITIONS
A. PLANNING DIVISION
1. Applicant shall meet all terms of the approved annexation,preliminary plat(H-2017-0129)
applications approved for this site and development agreements(Inst. #2018-052339 and H-2020-
0096,Instr.No 2021-025636).
2. The applicant shall obtain the City Engineer's signature on the final plat by August 10, 2023 in
accord with UDC 11-6B-7 in order for the preliminary plat to remain valid or a time extension
may be requested.
3. The final plat prepared by Sawtooth Land Surveying,LLC., dated January 2021 by Jeff Beagley,
shall be revised as follows:
a. Note#4: remove the reference to a conditional use permit.
b. Notes#19 &20: add instrument numbers.
c. There shall be a note added to the plat which indicates which lots access the common
driveways, and the entity responsible for the maintenance of these driveways.
4. All fencing installed on the site shall be consistent with the standards listed in UDC I I-3A-7. If
permanent fencing does not exist at the subdivision boundary,temporary construction fencing to
contain debris shall be installed around this phase prior to release of building permits.
5. Staff s failure to cite specific ordinance provisions or conditions from the preliminary plat does not
relieve the Applicant of responsibility for compliance.
6. Future homes constructed in this phase shall be consistent with the approved elevations contained
in modified development agreement H-2020-0096, Instr No. 2021-025636.
7. The development shall comply with standards and installation for landscaping as set forth in UDC
11-3B-5 and maintenance thereof as set forth in UDC 11-313-13.
8. Prior to the City Engineer's signature,the applicant shall obtain approval from the Post Master of
the proposed mailbox location(s).
9. All private streets shall be constructed in compliance with UDC 11-3F-4. For the purposes of this
application, the applicant shall only construct the portion of the private street in accord with this
phase. The reminder of the streets shall be constructed with a subsequent phase.
B. PUBLIC WORKS
1. Sanitary sewer service to this development is available via extension of existing mains adjacent to
the development. The applicant shall install mains to and through this subdivision; applicant shall
coordinate main size and routing with the Public Works Department, and execute standard forms
of easements for any mains that are required to provide service. Minimum cover over sewer mains
is three feet, if cover from top of pipe to sub-grade is less than three feet than alternate materials
shall be used in conformance of City of Meridian Public Works Departments Standard
Specifications.
2. Water service to this site is available via extension of existing mains adjacent to the development.
The applicant shall be responsible to install water mains to and through this development,
coordinate main size and routing with Public Works.
3. All improvements related to public life, safety and health shall be completed prior to occupancy of
the structures. Where approved by the City Engineer, an owner may post a performance surety for
Page 11
Page 119
Item#8.
such improvements in order to obtain City Engineer signature on the final plat as set forth in UDC
11-5C-3B.
4. Upon installation of the landscaping and prior to inspection by Planning Department staff, the
applicant shall provide a written certificate of completion as set forth in UDC 11-3B-14A.
5. A letter of credit or cash surety in the amount of 110%will be required for all incomplete fencing,
landscaping, amenities,pressurized irrigation,prior to signature on the final plat.
6. The City of Meridian requires that the owner post with the City a performance surety in the amount
of 125% of the total construction cost for all incomplete sewer, water infrastructure prior to final
plat signature. This surety will be verified by a line item cost estimate provided by the owner to the
City. The applicant shall be required to enter into a Development Surety Agreement with the City
of Meridian. The surety can be posted in the form of an irrevocable letter of credit,cash deposit or
bond. Applicant must file an application for surety, which can be found on the Community
Development Department website. Please contact Land Development Service for more
information at 887-2211.
7. The City of Meridian requires that the owner post to the City a warranty surety in the amount of
20% of the total construction cost for all completed sewer, and water infrastructure for a duration
of two years. This surety amount will be verified by a line item final cost invoicing provided by the
owner to the City. The surety can be posted in the form of an irrevocable letter of credit, cash
deposit or bond. Applicant must file an application for surety, which can be found on the
Community Development Department website. Please contact Land Development Service for
more information at 887-2211.
8. In the event that an applicant and/or owner cannot complete non-life, non-safety and non-health
improvements,prior to City Engineer signature on the final plat and/or prior to occupancy,a surety
agreement may be approved as set forth in UDC 11-5C-3C.
9. Applicant shall be required to pay Public Works development plan review, and construction
inspection fees, as determined during the plan review process, prior to the issuance of a plan
approval letter.
10. It shall be the responsibility of the applicant to ensure that all development features comply with
the Americans with Disabilities Act and the Fair Housing Act.
11. Applicant shall be responsible for application and compliance with any Section 404 Permitting that
may be required by the Army Corps of Engineers.
12. Developer shall coordinate mailbox locations with the Meridian Post Office.
13. All grading of the site shall be performed in conformance with MCC 11-14B.
14. Compaction test results shall be submitted to the Meridian Building Department for all building
pads receiving engineered backfill,where footing would sit atop fill material.
15. The engineer shall be required to certify that the street centerline elevations are set a minimum of
3-feet above the highest established peak groundwater elevation. This is to ensure that the bottom
elevation of the crawl spaces of homes is at least 1-foot above.
16. The applicants design engineer shall be responsible for inspection of all irrigation and/or drainage
facility within this project that do not fall under the jurisdiction of an irrigation district or ACHD.
The design engineer shall provide certification that the facilities have been installed in accordance
with the approved design plans.This certification will be required before a certificate of occupancy
is issued for any structures within the project.
17. At the completion of the project,the applicant shall be responsible to submit record drawings per
Page 12
Page 120
Item#8.
the City of Meridian AutoCAD standards. These record drawings must be received and approved
prior to the issuance of a certification of occupancy for any structures within the project.
18. Street light plan requirements are listed in section 6-7 of the Improvement Standards for Street
Lighting (http://www.meridiancity.org/public_works.aspx?id=272). All street lights shall be
installed at developer's expense. Final design shall be submitted as part of the development plan
set for approval, which must include the location of any existing street lights. The contractor's
work and materials shall conform to the ISPWC and the City of Meridian Supplemental
Specifications to the ISPWC. Contact the City of Meridian Transportation and Utility Coordinator
at 898-5500 for information on the locations of existing street lighting.
19. The applicant shall provide easement(s)for all public water/sewer mains outside of public right of
way (include all water services and hydrants). The easement widths shall be 20-feet wide for a
single utility,or 30-feet wide for two. The easements shall not be dedicated via the plat,but rather
dedicated outside the plat process using the City of Meridian's standard forms. The easement shall
be graphically depicted on the plat for reference purposes. Submit an executed easement (on the
form available from Public Works),a legal description prepared by an Idaho Licensed Professional
Land Surveyor,which must include the area of the easement(marked EXHIBIT A)and an 81/2"x
11" map with bearings and distances (marked EXHIBIT B) for review. Both exhibits must be
sealed, signed and dated by a Professional Land Surveyor. DO NOT RECORD. Add a note to the
plat referencing this document. All easements must be submitted,reviewed,and approved prior to
signature of the final plat by the City Engineer.
20. Applicant shall be responsible for application and compliance with and NPDES permitting that
may be required by the Environmental Protection Agency.
21. Any wells that will not continue to be used must be properly abandoned according to Idaho Well
Construction Standards Rules administered by the Idaho Department of Water Resources. The
Developer's Engineer shall provide a statement addressing whether there are any existing wells in
the development, and if so, how they will continue to be used, or provide record of their
abandonment.
22. Any existing septic systems within this project shall be removed from service per City Ordinance
Section 9-1-4 and 9 4 8. Contact the Central District Health Department for abandonment
procedures and inspections.
23. The City of Meridian requires that pressurized irrigation systems be supplied by a year-round
source of water(MCC 9-1-28.C.1). The applicant should be required to use any existing surface or
well water for the primary source. If a surface or well source is not available, a single-point
connection to the culinary water system shall be required. If a single-point connection is utilized,
the developer will be responsible for the payment of assessments for the common areas prior to
development plan approval.
24. All irrigation ditches, canals, laterals, or drains, exclusive of natural waterways, intersecting,
crossing or laying adjacent and contiguous to the area being subdivided shall be addressed per UDC
11-3A-6. In performing such work,the applicant shall comply with Idaho Code 42-1207 and any
other applicable law or regulation.
Page 13