PZ - Landscape Plan Development, INE 4 RETAIL PAD 2 T BER 2 21 RODNEY EVANS+PARTNERS C V�O Inc.c• 3 G 6 O C O , 0 PROJECT INFORMATION LANDSCAPE NOTES: TOPSOIL NOTES LANDSCAPE REQUIREMENTS 1. CONTRACTOR SHALL REPORT TO LANDSCAPE ARCHITECT ALL CONDITIONS WHICH IMPAIR AND/OR PREVENT THE PROPER 1. TOPSOIL REQUIREMENTS: ASTM D 5268, PH RANGE OF 5.5 TO 7, FOUR PERCENT ORGANIC MATERIAL MINIMUM, FREE OF STONES 1/2 EXECUTION OF THIS WORK, PRIOR TO BEGINNING WORK. INCH OR LARGER IN ANY DIMENSION,AND OTHER EXTRANEOUS MATERIALS HARMFUL TO PLANT GROWTH. TOTAL PROPERTY SIZE=38,480.59 S.F.-0.88 ACRES 2. NO MATERIAL SUBSTITUTIONS SHALL BE MADE WITHOUT THE LANDSCAPE ARCHITECT'S PRIOR WRITTEN APPROVAL. ALTERNATE 2. TOPSOIL SOURCE: STRIP EXISTING TOPSOIL FROM ALL AREAS OF THE SITE TO BE DISTURBED. TOPSOIL SHALL BE FERTILE, MATERIALS OF SIMILAR SIZE AND CHARACTER MAY BE CONSIDERED IF SPECIFIED PLANT MATERIALS CAN NOT BE OBTAINED. FRIABLE, NATURAL LOAM,SURFACE SOIL, REASONABLY FREE OF SUBSOIL,CLAY LUMPS, BRUSH,WEEDS AND OTHER LITTER,AND ZONING DISTRICT=C G FREE OF ROOTS,STUMPS,ORGANIC MATTER LARGER THAN 2 INCHES IN ANY DIMENSION,AND OTHER EXTRANEOUS OR TOXIC LOT IMPROVEMENTS AREA=38,480.59 S.F. 3. COORDINATE ALL WORK WITH ALL OTHER SITE RELATED DEVELOPMENT DRAWINGS. MATTER HARMFUL TO PLANT GROWTH. TOPSOIL SHALL BE SCREENED TO ACHIEVE THIS REQUIREMENT. BUILDING COVERAGE: 10,045.96 S.F. 4. COORDINATE WORK SCHEDULE AND OBSERVATIONS WITH LANDSCAPE ARCHITECT PRIOR TO CONSTRUCTION START-UP.5. ALL PLANT MATERIAL SHALL BE INSTALLED AS PER DETAILS. 3. REPRESENTATIVE SAMPLES SHALL BE TESTED FOR ACIDITY, FERTILITY AND GENERAL TEXTURE BY A RECOGNIZED COMMERCIAL HARDSCAPE COVERAGE: 18,391.28 S.F. OR GOVERNMENT AGENCY AND COPIES OF THE TESTING AGENCY'S FINDINGS AND RECOMMENDATIONS SHALL BE FURNISHED TO LANDSCAPE COVERAGE: 10,043.35 S.F. 6. ALL PLANT MATERIAL SHALL CONFORM TO THE AMERICAN NURSERYMAN STANDARDS FOR TYPE AND SIZE SHOWN. PLANTS WILL BE THE ARCHITECT'S REPRESENTATIVE BY THE CONTRACTOR. ALL TOPSOIL SHALL BE AMENDED TO ACHIEVE SPECIFIED PH AND NUMBER OF PARKING STALLS PROVIDED: REJECTED IF NOT IN A SOUND AND HEALTHY CONDITION. ORGANIC REQUIREMENTS. RE-TEST TOPSOIL PRIOR TO FINAL COMPLETION TO ENSURE REQUIREMENTS HAVE BEEN MET. NO 7. IN THE EVENT OF A PLANT COUNT DISCREPANCY, PLANT SYMBOLS SHALL OVERRIDE SCHEDULE QUANTITIES AND CALL OUT TOPSOIL SHALL BE PLACED WHILE IN A FROZEN OR MUDDY CONDITION. 12 STANDARD STALLS SYMBOL NUMBERS. 0 COMPACT STALLS 8. ALL PLANTING BEDS SHALL BE COVERED WITH A MINIMUM OF 3"DEPTH OF CASCADE COMPOST (2"MINUS). SUBMIT SAMPLE FOR 4. PLACE TOPSOIL IN AREAS WHERE REQUIRED TO OBTAIN THICKNESS AS SCHEDULED. PLACE TOPSOIL DURING DRY WEATHER. PROVIDE ADDITIONAL IMPORTED TOPSOIL REQUIRED TO BRING SURFACE TO PROPOSED FINISH GRADE,AS REQUIRED. 2 ADA STALLS APPROVAL.PRE-EMERGENT HERBICIDE SHALL BE APPLIED PRIOR TO MULCH INSTALLATION. 5. COMPACTED TOPSOIL THICKNESS AT THE FOLLOWING AREAS: TOTAL: 14 STALLS 9. ALL PLANT MATERIAL SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR BEGINNING AT THE DATE OF ACCEPTANCE BY THE A. LAWN AREAS:9 INCHES MINIMUM OR AS NECESSARY TO ACHIEVE EVEN GRADES WITH SURROUNDING LAWN AREAS. NUMBER OF BICYCLE PARKING SPACES REQUIRED: OWNER. REPLACE ALL PLANT MATERIAL FOUND DEAD OR NOT IN A HEALTHY CONDITION IMMEDIATELY WITH THE SAME SIZE AND B. PLANTER BEDS: 18 INCHES MINIMUM (1 STALLS/10 REQUIRED STALLS)=3 BICYCLE STALLS SPECIES AT NO COST TO THE OWNER. 6. FINE GRADE TOPSOIL TO SMOOTH, EVEN SURFACE WITH LOOSE, UNIFORMLY FINE TEXTURE. REMOVE RIDGES AND FILL NUMBER OF BICYCLE PARKING SPACES PROVIDED: 10. FINISH GRADES SHALL PROVIDE A SMOOTH TRANSITION WITH ADJACENT SURFACES AND ENSURE POSITIVE DRAINAGE IN DEPRESSIONS,AS REQUIRED TO MEET FINISH GRADES. FINISH GRADE OF TOPSOIL SHALL BE 2"BELOW FINISH GRADE OF PROPOSED ONE RACK(ONE RACK=3 STALLS) ACCORDANCE WITH THE SITE CIVIL GRADING PLAN. PAVEMENTS AREAS FOR SOD AND 1"FOR SEED. TOTAL NUMBER OF TREES:22 11. AMEND EXISTING APPROVED TOPSOIL AT A RATIO OF THREE CUBIC YARDS OF APPROVED COMPOST PER 1000 SQUARE FEET. 7. TOPSOIL STOCKPILE LOCATIONS TO BE COVERED COORDINATE WITH EROSION AND SEDIMENT CONTROL PLAN. TOTAL NUMBER OF TREE SPECIES REQUIRED: 3;7 SPECIES PROVIDED ROTO-TILL ORGANIC MATTER A MINIMUM OF 6 INCHES INTO TOPSOIL. 8. ALL GRAVEL,SUBBASE,AND OTHER IMPORTED FILL MATERIALS OTHER THAN TOPSOIL SHALL ONLY BE STOCKPILED IN PROPOSED 12. FERTILIZE ALL TREES AND SHRUBS WITH'AGRIFORM'PLANTING TABLETS. QUANTITY PER MANUFACTURER'S RECOMMENDATIONS. IMPERVIOUS AREAS. NO GRAVEL OR ROCK MATERIALS SHALL BE STOCKPILED OR TEMPORARILY PLACED IN PROPOSED PROVIDED PARKING LOT TREES-4 13. ALL PLANTING BEDS SHALL HAVE A MINIMUM 18"DEPTH OF TOPSOIL. LAWN AREAS SHALL HAVE A MINIMUM 12"DEPTH OF TOPSOIL. LANDSCAPE AREAS TO PREVENT LANDSCAPE AREAS FROM BEING CONTAMINATED WITH ROCK MATERIALS. CONTRACTOR SHALL LANDSCAPE BUFFER REQUIREMENTS: SPREAD,COMPACT,AND FINE GRADE TOPSOIL TO A SMOOTH AND UNIFORM GRADE 3"BELOW ADJACENT SURFACES OF PLANTER SUBMIT A DETAILED STOCKPILE PLAN TO LANDSCAPE ARCHITECT AND OWNER FOR APPROVAL PRIOR TO ANY EARTHWORK 3"DEPTH OF MULCH AT PLANTER WEST LANDSCAPE BUFFER(N.WEBB WAY) BED AREAS, 1-1/2"BELOW ADJACENT SURFACES OF TURF SOD AREAS,AND 1"BELOW ADJACENT SURFACES OF TURF SEED AREAS. OPERATIONS. BEDS 161.9 LIN. FT. 14. REUSE EXISTING TOPSOIL STOCKPILED ON THE SITE. SUPPLEMENT WITH IMPORTED TOPSOIL WHEN QUANTITIES ARE INSUFFICIENT. 8" 25-60 FT.WIDTH PARKING BUFFER PROVIDED VERIFY SUITABILITY AND CONDITION OF TOPSOIL AS A GROWING MEDIUM. PERFORM SOIL TEST/ANALYSIS AND PROVIDE (20 FT. LANDSCAPE BUFFER REQUIRED) ADDITIONAL AMENDMENT AS DETERMINED BY SOIL TESTS. TOPSOIL SHALL BE A LOOSE, FRIABLE,SANDY LOAM,CLEAN AND FREE IRRIGATION NOTES. REQUIRED TREES-10 OF TOXIC MATERIALS, NOXIOUS WEEDS,WEED SEEDS, ROCKS,GRASS OR OTHER FOREIGN MATERIAL AND A HAVE A PH OF 5.5 TO PROVIDED TREES-11 7.0. IF ONSITE TOPSOIL DOES NOT MEET THESE MINIMUM STANDARDS,CONTRACTOR IS RESPONSIBLE TO EITHER: 1. ALL LANDSCAPED AREAS SHALL HAVE AN AUTOMATIC UNDERGROUND SPRINKLER SYSTEM WHICH INSURES COMPLETE COVERAGE A)PROVIDE APPROVED IMPORTED TOPSOIL,OR AND PROPERLY ZONED FOR REQUIRED WATER USES. EACH HYDROZONE IS TO BE IRRIGATED WITH SEPARATE INDIVIDUAL = - � Wp': 11 1= B)IMPROVE ON-SITE TOPSOIL WITH METHODS APPROVED BY THE LANDSCAPE ARCHITECT. STATIONS. - - NORTH BOUNDARY LANDSCAPE BUFFER(N. FAIRVIEW AVE.) 15. IF IMPORTED TOPSOIL FROM OFF-SITE SOURCES IS REQUIRED, ENSURE IT IS FERTILE, FRIABLE, NATURAL LOAM,SURFACE SOIL, 2. PLANTER BEDS AND LAWN AREAS ARE TO HAVE SEPARATE HYDRO-ZONES. -� i- - APPROVED TOPSOIL AND SOIL NOT APPLICABLE-EXISTING DEVELOPMENT REASONABLY FREE OF SUBSOIL,CLAY LUMPS, BRUSH,WEEDS AND OTHER LITTER,AND FREE OF ROOTS,STUMPS,STONES LARGER 3. POP-UP SPRINKLER HEADS SHALL HAVE A MINIMUM RISER HEIGHT OF 4 INCHES AT LAWN AREAS AND 18"AT PLANTER BEDS. _III III III i�'THAN 2 INCHES IN ANY DIMENSION,AND OTHER EXTRANEOUS OR TOXIC MATTER HARMFUL TO PLANT GROWTH. 4. PLANTER BEDS ARE TO HAVE DRIP IRRIGATION SYSTEM OR POP-UP SPRAY SYSTEM.ANNUALS, PERENNIALS GROUND COVERS OR FINISH GRADE, AMENDMENTS AS SPECIFIED EAST BOUNDARY LANDSCAPE BUFFER A) OBTAIN TOPSOIL FROM LOCAL SOURCES OR FROM AREAS HAVING SIMILAR SOIL CHARACTERISTICS TO THOSE FOUND ON THE SHRUB MASSINGS SHALL HAVE A POP-UP SPRAY SYSTEM. PER PLANS NOT APPLICABLE-FUTURE BUILDING PAD PROJECT SITE. OBTAIN TOPSOIL ONLY FROM NATURALLY,WELL-DRAINED SITES WHERE TOPSOIL OCCURS AT A DEPTH OF NOT 5. ELECTRONIC WATER DISTRIBUTION/TIMING CONTROLLERS ARE TO BE PROVIDED. MINIMUM CONTROLLER REQUIREMENTS ARE AS LESS THAN 4 INCHES. FOLLOWS: PLANTER BED CUT EDGE SOUTH BOUNDARY LANDSCAPE BUFFER(FUTURE DEVELOPMENT) B) REPRESENTATIVE SAMPLES SHALL BE TESTED FOR ACIDITY, FERTILITY,TOXICITY,AND GENERAL TEXTURE BY A RECOGNIZED a. PRECISE INDIVIDUAL STATION TIMING 184.7 LIN. FT. COMMERCIAL OR GOVERNMENT AGENCY AND COPIES OF THE TESTING AGENCY'S FINDINGS AND RECOMMENDATIONS SHALL BE b. RUN TIME CAPABILITIES FOR EXTREMES IN PRECIPITATION RATES NOT TO SCALE 15.3 FT. BUFFER PROVIDED FURNISHED TO THE OWNER'S REPRESENTATIVE BY THE CONTRACTOR. NO TOPSOIL SHALL BE DELIVERED IN A FROZEN OR c. AT LEAST ONE PROGRAM FOR EACH HYDROZONE (TYPICAL AT TREES IN TURF AREAS) (25 FT. LANDSCAPE BUFFER REQUIRED) MUDDY CONDITION.ACIDITY/ALKALINITY RANGE-PH.5.5 TO 7.6. d. SUFFICIENT MULTIPLE CYCLES TO AVOID WATER RUN-OFF 16. IMMEDIATELY CLEAN UP ANY TOPSOIL OR OTHER DEBRIS ON THE SITE CREATED FROM LANDSCAPE OPERATIONS AND DISPOSE OF e. POWER FAILURE BACKUP FOR ALL PROGRAMED INDIVIDUAL VALVED WATERING STATIONS WILL BE DESIGNED AND INSTALLED REQUIRED TREES-5 PROPERLY OFF SITE. TO PROVIDE WATER TO RESPECTIVE HYDRO-ZONES. PROVIDED TREES-10 17. TREES SHALL NOT BE PLANTED WITHIN S-0"FROM THE BACK OF SIDEWALK. 6. INDIVIDUAL VALVED WATERING STATIONS WILL BE DESIGNED AND INSTALLED TO PROVIDE WATER TO RESPECTIVE HYDRO-ZONES. 18. TREES SHALL NOT BE PLANTED WITHIN THE 10'-0"CLEAR ZONE OF ALL STORM DRAIN PIPE,STRUCTURES,OR FACILITIES. 7. THE IRRIGATION SYSTEM SHALL BE DESIGNED TO PROVIDE 100%HEAD TO HEAD COVERAGE WITH TRIANGULAR SPACING. 19. STORM DRAINAGE FACILITIES MUST BE PROTECTED FROM ANY AND ALL CONTAMINATION DURING THE CONSTRUCTION AND 8. SPRINKLER HEADS SHALL BE ADJUSTED TO REDUCE OVERSPRAY ONTO IMPERVIOUS SURFACES(BUILDINGS,SIDEWALKS, INSTALLATION OF THE LANDSCAPE IRRIGATION SYSTEM. DRIVEWAYS,AND ASPHALT AREAS). A' A' 20. IN THE EVENT OF A DISCREPANCY, NOTIFY THE LANDSCAPE ARCHITECT IMMEDIATELY. 9. PROVIDE MINIMUM(1)QUICK COUPLER VALVE PER EACH(6)AUTOMATIC VALVE ZONES. APPROVE Q.C.V. LOCATIONS WITH LANDSCAPE ARCHITECT. WEED ABATEMENT NOTES. A=LENGTH,AS SPECIFIED OR PER PLANT SCHEDULE 1. ALL AREAS TO BE PLANTED OR HYDROSEEDED SHALL HAVE WEED ABATEMENT OPERATIONS PERFORMED ON THEM PRIOR TO PLANTING OR HYDROSEEDING. 9- P B=85%OF'A' 2. CONTRACTOR SHALL SPRAY ALL EXPOSED WEEDS WITH"ROUND-UP"(CONTACT HERBICIDE)OR APPROVED EQUAL. 3. DO NOT WATER FOR AT LEAST SEVEN (7)DAYS. REMOVE EXPOSED WEEDS FROM THE SITE. + 4. CONTRACTOR SHALL OPERATE THE AUTOMATIC IRRIGATION SYSTEM FOR A PERIOD OF FOURTEEN(14)DAYS. AT CONCLUSION OF REMOVE ANY PLASTIC, BURLAP, NAILS,OR OTHER THIS WATERING PERIOD, DISCONTINUE WATERING FOR THREE TO FIVE(3-5) DAYS. •• MATERIALS FROM THE ROOTBALL WHICH MAY LIMIT 5. APPLY SECOND APPLICATION OF"ROUND-UP"TO ALL EXPOSED WEEDS. APPLY IN STRICT CONFORMANCE WITH MANUFACTURER'S ROOT GROWTH PLAN VIEW FINISH GRADE PER PLANS SPECIFICATIONS AND INSTRUCTIONS. DO NOT WATER FOR AT LEAST SEVEN(7)DAYS. REMOVE WEEDS FROM THE SITE. • 6. IF ANY EVIDENCE OF WEED GERMINATION EXISTS AFTER TWO(2)APPLICATIONS,CONTRACTOR SHALL BE DIRECTED TO PERFORM A • • CONSTRUCT 2"EARTH BERM TO FORM A WATER GROUNDCOVER PLANTING PER PLANTING PLAN THIRD APPLICATION. - RETENTION BASIN, FILL BERM WITH MULCH,AS 7. AT THE TIME OF PLANTING AND HYDROSEEDING,ALL PLANTING AREAS SHALL BE WEED FREE. SPECIFIED MULCH, PER PLANS,3"DEPTH OVER ENTIRE BED. • DO NOT COVER CROWNS OF PLANTS v �. • MULCH, PER PLANS, 3"DEPTH OVER ENTIRE BED. DO �p�'- g�° TILL SOIL TO A DEPTH OF 12", BACKFILL WITH NOT COVER CROWNS OF PLANTS u �e� APPROVED TOPSOIL AND SOIL AMENDMENTS,AS PROVIDE COMMERCIAL FERTILIZER TABLETS AND - _ �_ SPECIFIED. BIOSTIMULANT,AS SPECIFIED, FOR EACH SHRUB �� SUBGRADE BACKFILL WITH APPROVED TOPSOIL AND SOIL N // //�//�//�//�//�//�//�//�//�//�/ / AMENDMENTS,AS SPECIFIED. BACKFILL IN 6"LIFTS, -h��V��y�YV�� �YV��V��V��V��V��V��V��V��� I_-1 Iii ii ii ii ii ii WATER EACH LAYER, DO NOT TAMP OR OVER • I COMPACT. ": . :. •.:: ;•: =III=III=III=III=III-III-I I =III-1 - _ III III I I. : :.:. 5 :' ,,.> :,:: ;:•_;.,:.`.: :. rj 12" WIDTH OF 12" CONSTRUCT 6"MOUND OF TOPSOIL _/ T IN �MIN. ROOTBALL M I '/{/� , . :,��>:��.°•:�r::' � •:I�..: SECTION / Y r\ a�: 1 FNOTES: -N- : 5 'I':j 5 PO 110111 7_ 1. SHRUB SHALL BEAR SAME RELATIONSHIP TO GRADE AS IT DID IN NURSERY. NOTES: �'- 3 12 6 �� S 10 2. WATER SHRUB TWICE WITHIN FIRST 24 HOURS. 1. ALL GROUNDCOVER PLANTS TO BE PLANTED ON CENTER AND IN A TRIANGULAR PATTERN. 2 CA RF RF 3 RF 3. THIN BRANCHES AND FOLIAGE BY%3. 2. APPLY SPECIFIED PRE-EMERGENT PER MANUFACTURER'S RECOMMENDATIONS TO ALL GROUNDCOVER .+'�""""'�"`•• '. \ 15 1 1 L01 1 4. DO NOT CUT LEADERS TO RETAIN NATURAL SHRUB SHAPE. BEDS. 5. FOR CONTAINER GROWN PLANTS THAT ARE ROOTBOUND, SPLIT THE ROOTBALL WITH 3 EQUAL SPACED . .. GT GT GT VERTICAL CUTS. 4 3 ® 5 }'. ` ` :: :• :: . ':.::. CM CM CM SHRUB PLANTING GROUNDCOVER / PERENNIAL NOT TO SCALE 3 NOT TO SCALE PLANTING 1 GT i kP jBGj 1 1 LANDSCAPE LEGEND PP Lot PLANT SCHEDULE o�, �; •., :1• �' :.��:•c•',tF / tit \ �' J :' < ..• -: :•°:. ::, . PC QTY KEY BOTANICAL NAME COMMON NAME SIZE NOTES +''•�� ~�t;• DECIDUOUS SHADE TREES t TREES/PLANTS TO BE INSTALLED 4 Ir GT Gleditsia triacanthos'Shademaster' Shademaster Honeylocust 2"CAL.B&B Class II-45'H x 35'W t \ �4. 3 `�.; 'fir"•, :�: .. : -:: BUILDING G i 0 t 3 PL Platanus acerifolia'Morton Circle' EXCLAMATION.Tm London planetree 2"CAL.B&B Class II 55'H x 35'W \ _ '`•' t ° i 4 ZS Zelkova serrata'Green Vase' Green Vase Zelkova 2"CAL.B&B Class II-45'H x 30'W _ _ _ _ _ _ _ EDGING AS DETAILED 4 �, / \ �• PROPERTY LINE(VERIFY) ��� i CONIFEROUS TREES ZS `` ,:•• �: i ` I•i ��` 4 CD Cedrus deodara'Shalimar' Shalimar Deodora Cedar 6'-7'HGT.B&B 15'H x 12'W PROPOSED 6'-0'TALL VINYL FENCE, t o 0 0 o COLOR TO BE DETERMINED BY t 7 SF 2 PA Picea abies'Columnaris' Columnar Norway Spruce 6'-7'HGT.B&B 20'H x 10'W (n ►�• \.:. .�•, r- / OWNER.SEE DETAIL 3/L02 Z. ,r• ORNAMENTAL TREES FQCI QUANTITY ;. ,. : . PLANT IDENTIFICATION KEY ; ��•?°'• .' ::, 3 MA Malus x"Royal Raindrops' Royal Raindrops®Flowering Crabapple 3"CAL.B&B Class I-20'H x 15'W (n I '.:A'. :. :`` �. 1 + 2 PY Pyrus calleryana'Capital' Capital Flowering Pear 2"CAL.B&B Class I-35'H x 15'W AL I Il�.'`"� �`"•} M4 �- MAINTAINED LAWN AREAS ,,•� •..'.:•:�•=,:• 'r, •,•,'•: TURF SOD AND TOPSOIL AS . ..,:. 3 PL SHRUBS/PERENNIALS/ORNAMENTAL GRASSES •�' '� �` ' ��` • i .. .:,-: �-� SPECIFIED ` �:';':: : ::::: ' • ' 2 18 AR Ajuga reptans'Black Scallop' Black Scallop Carpet Bugle #1;24"o.c. 6"H x 2'W i °�. .,,::;;:;`; L01 18 10 BG Buxus x'Green Velvet' Green Velvet Boxwood #2 3'H x 3'W .:' AR 12 CA Calama rostis x acutiflora'Karl Foerster' Foerster's Feather Reed Grass #2 4-5'H x 3'W 5 19 g CASCADE BARK MULCH AT 3" ti ,, :.y- 8 13 PL - 0 41 CM Carex morrowii'Ice Dance' Ice Dance Japanese Sedge #1 2'H x T W DEPTH OVER TOPSOIL AS i VS 1 SPECIFIED (!) �•r" _ EA 4 2 29 RF 6 8 EA Euonymus alatus'Compactus' Dwarf Burning Bush #5 4'H x 4'W • • • • • \+ .••' .�,` .'•.: T• CID PY L02 CM VS . 15 PF Photinia x fraseri Fraser's Photinia #5 8'H x 6'W 19 PL Prunus laurocerasus'Otto Luyken' Otto Luyken English Laurel #5 4'H x 4'W CALLOUT NUMBERS Q0000000 `t 'r\fir Y REFER TO NUMBERED . i \I ` . t1�+► 18 PO Physocarpus opulifolius'Monlo' Diabolo®Ninebark #5 5'H x 5'W CALLOUT NOTES NOTES BELOW oc �',,:4':•:::: ,: i + • ��CC g 10 RH Rhamnus frangula'Columnaris' Tallhedge Buckthorne #5 12'H x 3-4'W oo ` J 1. VISION TRIANGLE o0 VS 0 45 RF Rudbeckia fulgida var.sullivantii'Goldsturm' Goldsturm Black-Eyed Susan #1 2'H x T W o 2. PROPOSED TRASH ENCLOSURE o ` 20 VS Veronica spicata'Purpleicious' Purpleicious Speedwell #1 1.5'H x 1.5'W 3. NEW BIKE PARKING or I ' MING PER PLANS 10 11 2 15 9 2 °2 ' RH PO MA PF 6 END CA PA L02 5. EXISTING LANDSCAPE PROPOSED EARTH RPREVIOUS PHASE °°oJ� 12/09 1 BEGIN 6 #A1ug24eoptcns'Black Scallop' V1 ro3i aospicata'Purpleicious' 6 DETOERMINED BY OWNER. POSED 6'-0"TALL YL FENCE, COLOR TO BE °000000 oD$�o 0 00 000° I FUTURE WILSON RD . Scale : 1" = 20' LANDSCAPE PLAN 40 21285 Conditional Use Permit pg. L01