Loading...
Verizon SWC Overland and Meridian - CZC - A-2020-0128 ACHD Email_BOI Roaring Walowes SC.pdfDate Rebecca W. Arnold, President Mary May, 1st Vice-President Sara M. Baker, 2nd Vice-President Jim D. Hansen, Commissioner Kent Goldthorpe, Commissioner ________________________________________ _____________________________________________________________________ Ada County Highway District • 3775 Adams Street • Garden City, ID • 83714 • PH 208-387-6100 • FX 345-7650 • www.achdidaho.org March 25, 2019 To: Jodie Knopp TAEC/ Verizon Wireless 6126 W. State Street Boise, ID 83703 Subject: MER19-0024/ A-2019-0109 Southwest Corner of Overland Road and Meridian Road Verizon Wireless Antenna on ACHD Traffic Light Structure In response to your request for comment, the Ada County Highway District has reviewed the submitted application and site plan for the item referenced above. It has been determined that ACHD has site specific conditions of approval for this application. A. Findings of Fact 1. Applicant’s Proposal: The applicant is proposing to install one Verizon canister antenna, one equipment enclosure, three 5g antennas, and two exterior mounted conduits to the top of the existing traffic light structure located in the right-of-way at the southwest corner of east Overland Road and south Meridian Road. 2. Staff Comments/Recommendations: The applicant should comply with the requirements of the ACHD Master License Agreement dated April 19, 2017, and obtain an approved site license from ACHD for the southwest corner of east Overland Road and south Meridan Road location in accordance with the Master License Agreement. The applicant may install one Verizon canister antenna to the top of the existing traffic light structure located in the right-of-way at the southwest corner of east Overland Road and south Meridian Road once ACHD has approved the site license. The site license does not constitute the issuance of a permit. The applicant is required to apply for and obtain a permit for all work within the ACHD right-of-way. B. Site Specific Conditions of Approval 1. Comply with the requirements of the ACHD Master License Agreement dated April 19, 2017, and obtain a site license from ACHD for the southwest corner of east Overland Road and south Meridian Road location in accordance with the Master License Agreement. 2. Comply with the Standard Conditions of Approval as noted below. C. Attachments 1. Vicinity Map 2. Site Plan 3. Standard Conditions of Approval 4. Appeal Guidelines _____________________________________________________________________________________________________________ Ada County Highway District • 3775 Adams Street • Garden City, ID • 83714 • PH 208-387-6100 • FX 345-7650 • www.achdidaho.org If you have any questions, please feel free to contact me at (208) 387-6132. Sincerely, Elizabeth Allen Planning Review Intern Development Services cc: City of Meridian _____________________________________________________________________________________________________________ Ada County Highway District • 3775 Adams Street • Garden City, ID • 83714 • PH 208-387-6100 • FX 345-7650 • www.achdidaho.org VICINITY MAP ______________________________________________________ _______________________________________________________ Ada County Highway District • 3775 Adams Street • Garden City, ID • 83714 • PH 208-387-6100 • FX 345-7650 • www.achdidaho.org SITE PLAN _____________________________________________________________________________________________________________ Ada County Highway District • 3775 Adams Street • Garden City, ID • 83714 • PH 208-387-6100 • FX 345-7650 • www.achdidaho.org Standard Conditions of Approval 1. All proposed irrigation facilities shall be located outside of the ACHD right-of-way (including all easements). Any existing irrigation facilities shall be relocated outside of the ACHD right-of-way (including all easements). 2. Private Utilities including sewer or water systems are prohibited from being located within the ACHD right-of-way. 3. In accordance with District policy, 7203.6, the applicant may be required to update any existing non-compliant pedestrian improvements abutting the site to meet current Americans with Disabilities Act (ADA) requirements. The applicant’s engineer should provide documentation of ADA compliance to District Development Review staff for review. 4. Replace any existing damaged curb, gutter and sidewalk and any that may be damaged during the construction of the proposed development. Contact Construction Services at 387-6280 (with file number) for details. 5. A license agreement and compliance with the District’s Tree Planter policy is required for all landscaping proposed within ACHD right-of-way or easement areas. 6. All utility relocation costs associated with improving street frontages abutting the site shall be borne by the developer. 7. It is the responsibility of the applicant to verify all existing utilities within the right-of-way. The applicant at no cost to ACHD shall repair existing utilities damaged by the applicant. The applicant shall be required to call DIGLINE (1-811-342-1585) at least two full business days prior to breaking ground within ACHD right-of-way. The applicant shall contact ACHD Traffic Operations 387-6190 in the event any ACHD conduits (spare or filled) are compromised during any phase of construction. 8. Utility street cuts in pavement less than five years old are not allowed unless approved in writing by the District. Contact the District’s Utility Coordinator at 387-6258 (with file numbers) for details. 9. All design and construction shall be in accordance with the ACHD Policy Manual, ISPWC Standards and approved supplements, Construction Services procedures and all applicable ACHD Standards unless specifically waived herein. An engineer registered in the State of Idaho shall prepare and certify all improvement plans. 10. Construction, use and property development shall be in conformance with all applicable requirements of ACHD prior to District approval for occupancy. 11. No change in the terms and conditions of this approval shall be valid unless they are in writing and signed by the applicant or the applicant’s authorized representative and an authorized representative of ACHD. The burden shall be upon the applicant to obtain written confirmation of any change from ACHD. 12. If the site plan or use should change in the future, ACHD Planning Review will review the site plan and may require additional improvements to the transportation system at that time. Any change in the planned use of the property which is the subject of this application, shall require the applicant to comply with ACHD Policy and Standard Conditions of Approval in place at that time unless a waiver/variance of the requirements or other legal relief is granted by the ACHD Commission. __________________________________ ___________________________________________________________________________ Ada County Highway District • 3775 Adams Street • Garden City, ID • 83714 • PH 208-387-6100 • FX 345-7650 • www.achdidaho.org Request for Appeal of Staff Decision 1. Appeal of Staff Decision: The Commission shall hear and decide appeals by an applicant of the final decision made by the Development Services Manager when it is alleged that the Development Services Manager did not properly apply this section 7101.6, did not consider all of the relevant facts presented, made an error of fact or law, abused discretion or acted arbitrarily and capriciously in the interpretation or enforcement of the ACHD Policy Manual. a. Filing Fee: The Commission may, from time to time, set reasonable fees to be charged the applicant for the processing of appeals, to cover administrative costs. b. Initiation: An appeal is initiated by the filing of a written notice of appeal with the Secretary and Clerk of the District, which must be filed within ten (10) working days from the date of the decision that is the subject of the appeal. The notice of appeal shall refer to the decision being appealed, identify the appellant by name, address and telephone number and state the grounds for the appeal. The grounds shall include a written summary of the provisions of the policy relevant to the appeal and/or the facts and law relied upon and shall include a written argument in support of the appeal. The Commission shall not consider a notice of appeal that does not comply with the provisions of this subsection. c. Time to Reply: The Development Services Manager shall have ten (10) working days from the date of the filing of the notice of appeal to reply to the notice of the appeal, and may during such time meet with the appellant to discuss the matter, and may also consider and/or modify the decision that is being appealed. A copy of the reply and any modifications to the decision being appealed will be provided to the appellant prior to the Commission hearing on the appeal. d. Notice of Hearing: Unless otherwise agreed to by the appellant, the hearing of the appeal will be noticed and scheduled on the Commission agenda at a regular meeting to be held within thirty (30) days following the delivery to the appellant of the Development Services Manager’s reply to the notice of appeal. A copy of the decision being appealed, the notice of appeal and the reply shall be delivered to the Commission at least one (1) week prior to the hearing. e. Action by Commission: Following the hearing, the Commission shall either affirm or reverse, in whole or part, or otherwise modify, amend or supplement the decision being appealed, as such action is adequately supported by the law and evidence presented at the hearing. Affidavit of Legal Interest_BOI Roaring Walowes SC.pdf Approved CZC_A-2019-0109_BOI Roaring Walowes SC.pdfCZC Conditions Document 1 Verizon SWC Overland and Meridian - CZC - A-2019-0109 CERTIFICATE OF ZONING COMPLIANCE REPORT DATE: March 13, 2019 TO: Jodie Knopp, TAEC / Verizon Wireless FROM: Ryan McKell, Assistant City Planner SUBJECT: Verizon SWC Overland and Meridian - CZC (A-2019-0109) ACHD OWNER: DESCRIPTION OF APPLICANT'S REQUEST The applicant, Jodie Knopp, requests Certificate of Zoning Compliance (CZC) approval on behalf of their client, Verizon Wireless, proposes to collocate one (1) small cell antenna and equipment enclosures located on an existing traffic signal pole in the public right of way. The site is located on an existing traffic signal pole at the southwest corner of W. Overland Rd. and S. Meridian Rd. DECISION The applicant's request for Certificate of Zoning Compliance is approved with the conditions listed in this report. Note: This is not a building permit. Please contact Building Services at (208) 887-2211 to verify if you need a building permit and/or inspection. If you do need a building permit, you must complete that process before you commence the use or construction. Please contact Building Services for additional details about building permits and inspections. Process Conditions of Approval 1. The applicant shall complete all improvements related to public life, safety, and health as set forth in UDC 11-5C-3B. A surety agreement may be accepted for other improvements in accord with UDC 11-5C-3C. 2. The site plan prepared by Technology Associates on February 25, 2019, labeled C100, is approved by the City of Meridian Planning Division as shown in Exhibit B. 3. The equipment details prepared by Technology Associates on February 25, 2019, labeled C300, is approved by the City of Meridian Planning Division as shown in Exhibit C. 4. The elevations prepared by Technology Associates on February 25, 2019, labeled C201, are approved by the City of Meridian Planning Division as shown in Exhibit D. 5. The approved site plan and/or elevations may not be altered without prior written approval of the City of Meridian Planning Division. 6. If any changes must be made to the site plan to accommodate ACHD requirements, the applicant shall submit a new site plan to the City of Meridian Planning Division for approval prior to issuance of the building permit. The applicant shall execute a license agreement with ACHD prior to installing the proposed wireless communication equipment, per the master agreement on file with the City. Conditions Document 2 Verizon SWC Overland and Meridian - CZC - A-2019-0109 Ongoing Conditions of Approval 1. The project is subject to all current City of Meridian ordinances and previous conditions of approval associated with this site (DA #105134293) 2. The issuance of this CZC does not release the applicant from any previous requirements of the other permits issued for the site. 3. The applicant and/or assigns shall have the continuing obligation to meet the specific use standards for the proposed use as set forth in UDC 11-4-3-43. CITY COUNCIL REVIEW The applicant or a party of record may request City Council review of a decision of the Director. All requests for review shall be filed in writing with the Planning Division on or before March 28, 2019, within fifteen (15) days after the written decision is issued, and contain the information listed in UDC 11-5A-6B. If City Council review of the decision is not requested, the action of the Director represents a final decision on a land use application. You have the right to request a regulatory taking analysis under Idaho Code 67-8003. EXPIRATION The Certificate of Zoning Compliance shall expire if the construction, alteration or the use has not commenced within one year of the date of issuance of the Certificate of Zoning Compliance. In accord with the above provisions, the subject Certificate of Zoning Compliance is valid until March 13, 2020. EXHIBITS A: Vicinity Map B: Site Plan (dated: February 25, 2019) C: Equipment Details (dated: February 25, 2019) D: Elevations (dated: February 25, 2019) Conditions Document 3 Verizon SWC Overland and Meridian - CZC - A-2019-0109 Exhibit A: Vicinity Map Conditions Document 4 Verizon SWC Overland and Meridian - CZC - A-2019-0109 Exhibit B: Site Plan (dated: February 25, 2019) Conditions Document 5 Verizon SWC Overland and Meridian - CZC - A-2019-0109 Exhibit C: Equipment Details (dated: February 25, 2019) Conditions Document 6 Verizon SWC Overland and Meridian - CZC - A-2019-0109 Exhibit D: Elevations (dated: February 25, 2019) LDAV_BOI Roaring Walowes SC.pdfMicrosoft Outlook - Memo Style 1 Jodie Knopp From: noreply@meridiancity.org Sent: Monday, March 11, 2019 10:29 AM To: Jodie Knopp; tricks@meridiancity.org; rbeecroft@meridiancity.org Subject: Address Verification Complete Address verification is complete for record LDAV-2019-0155 Project: VZW BOI Roaring Walowes SC Address: 1625 S MERIDIAN RD MERIDIAN, ID 83642 Parcel(s): R5652350010 Lot: 1 Block: 1 Subdivision: MEDINA SUB City of Meridian 33 E. Broadway Ave., Meridian, Idaho 83642 Phone: 208-888-4433 www.meridiancity.org All e-mail messages sent to or received by City of Meridian e-mail accounts are subject to the Idaho law, in regards to both release and retention, and may be released upon request, unless exempt from disclosure by law. Narrative_BOI Roaring Walowes SC.pdf Headquarters 3129 Tiger Run Court Suite 205 Carlsbad, CA 92010 Tel (760) 765-5275 www.taec.net June 19, 2020 City of Meridian Community Development & Planning Division 33 East Broadway Avenue Suite 102 Meridian, ID 83642 Re: BOI ROARING WALOWES SC – Verizon Wireless small cell addition to ACHD traffic signal / SW corner of E. Overland Rd. and S. Meridian Rd. To Whom It May Concern: Verizon Wireless is proposing to collocate on the existing traffic signal located at the southwest corner of the intersection of East Overland Road & South Meridian Road, Meridian, ID 83642. The proposed installation will consist of one (1) small cell canister antenna, one (1) equipment enclosure at the top of the pole, three (3) new technology antennas, and two (2) exterior mounted conduits. There will also be two (2) small ground vaults added near the base of the pole to house power and fiber. The new equipment is intended to provide new technology and relieve capacity coverage of the area. I appreciate your help and attention to this matter. Please feel free to contact me with any questions or if you need additional information. Regards, Jodie Knopp Technology Associates EC INC. Senior Project Manager | jodie.knopp@taec.net | 307.254.0554 6126 W. State St. | Ste. 205 | Boise | ID 83703 Site Elevation_Site Elevation C200.pdfA9Rwshk5e_6ckooq_2qk.tmp C200 SITE ELEVATION ACHD PROJECT Site Elevation_Site Elevation C201.pdfA9Rwshk5e_6ckooq_2qk.tmp ACHD PROJECT C201 SITE ELEVATION Site Plan_1A Certified Survey.pdfA9Rwshk5e_6ckooq_2qk.tmp 21.7' (AGL) GRADE/SIDEWALK 2621.5' 40.6' (AGL) TOP OF POLE 16.1' (AGL) 13.1' (AGL) 8.8' (AGL) 39.7' (AGL) 0.7' (AGL) 34.6' (AGL) 43.9' (AGL)CAMERA 38.0' (AGL)LIT R/W R/W R/W R/W R/W R/W R/W R GS GS GS GS GS GS GS GS GS GS GS WALGREENS M 8' PEDESTRIAN POLE PEDESTRIAN POLE SIGNAL CONTROL BOXES 1625 S MERIDIAN ROAD MERIDIAN, IDAHO 83642 FOR INFORMATIONAL PURPOSES ONLY ORIGINAL SIGNED BY: RONALD M. HODGE, PLS DATE ORIGINAL SIGNED: 01-23-2019 ORIGINAL ON FILE AT THE OFFICE OF FOX LAND SURVEYS, INC. SCALE 1"=20' (11x17) SCALE 1"=10' (22x34) AFIELD SURVEYED ON01-14-19JRRMH B1-A CERTIFICATION SURVEY WITHOUT UTILITY LOCATES01-18-19TRCRMH LATITUDE: LONGITUDE: GROUND ELEVATION: STRUCTURE HEIGHT (AGL): TALLEST APPURTENANCE HEIGHT (AGL): FAA-FCC 1A GEODETIC COORDINATES (83/88) 43°35'23.70" N 116°23'38.42" W 2622' 799.2m 41' 44' BASIS OF GEODETIC COORDINATES: (1) THE GEODETIC COORDINATES SHOWN HEREON WERE DERIVED FROM THE NATIONAL GEODETIC SURVEY (OPUS) UTILITY VIA STATIC GPS OBSERVATIONS UPON THE PROJECT CONTROL POINT. ALL SUBSEQUENT OBSERVATIONS WERE PROCESSED USING THE MICRO-SURVEY STAR*NET-PRO UTILITY AND/OR OTHER SOFTWARE UTILITIES. (2) HORIZONTAL DATUM: THE NORTH AMERICAN DATUM OF 1983 (NAD83)(2011)(EPOCH 2010) IS EXPRESSED IN DEGREES (°) MINUTES (') AND SECONDS (") AND ARE SHOWN TO THE 100TH OF A SECOND. (3) VERTICAL DATUM: THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88) (GEOID 12B) IS EXPRESSED IN U.S. SURVEY FEET AND IN METERS. C100% FINAL SURVEY FOR CLIENT, FRANCHISEE & AGENCY APPROVALS01-25-19TRCRMH 5 0 10 20 DWG: 19009-01MSFLSI PROJ#: 19009-01 DATEBYCHK THESE DRAWINGS AND SURVEYS ARE COPYRIGHT PROTECTED AND THE SOLE PROPERTY OF FOX LAND SURVEYS INC. AND PRODUCED FOR THE USE OF OUR CLIENT. ANY REPRODUCTION OR USE OF THE INFORMATION CONTAINED WITHIN SAID DOCUMENTS IS PROHIBITED WITHOUT THE WRITTEN CONSENT BY FOX LAND SURVEYS INC. 1515 S. Shoshone Street, Boise, Idaho 83705 www.foxlandsurveys.com Tel: 208-342-7957 DESIGNED FOR: DESCRIPTION SU - 1 SHEET NAME 1A CERTIFIED SURVEY 10" LIGHT POLE ON 2' DIA CONC BASE VALVEv FIRE HYDRANT IRRIGATION BOX TREE, TRUNK DIAMETER IN INCHES, CANOPY DRAWN TO SCALE CATCH BASIN MAIL BOX BOLLARD MB COMMUNICATIONS RISER EDGE OF PAVEMENTEP EP EP EP R/W RIGHT-OF-WAY WATER LINEW W W W C C C C COMMUNICATIONS LINE OVERHEAD POWER LINEOHP OHP OHP CENTER LINE POWER LINEP P P P EDGE OF GRASSGS GS GS GS EDGE OF GRAVELEG EG EG EG SD SD SD SD STORM DRAIN LINE S S S S SEWER LINE G G G G GAS LINE PAINT STRIPE EDGE OF DIRT ROADRD RD RD RD GEO-THERMO LINEGEO GEO GEO AS ASPHALTIC SURFACE BLD BUILDING CONC CONCRETE SURFACE GVL GRAVEL GRS GRASS PLT PLANTER NTS NOT TO SCALE UTILITY POLE SIGN P MANHOLE M METER UTILITY POLE (DIP POLE) UTILITY POLE WITH TRANSFORMERPx GUY ANCHOR JB JUNCTION BOX TRAFFIC SIGNAL ARM STREET LIGHT ARM Pd B SURVEYOR'S CERTIFICATION: I RONALD M. HODGE, IDAHO PLS 8575, HEREBY CERTIFY TO TECHNOLOGY ASSOCIATES EC AND VERIZON WIRELESS: THAT THIS "POLE SITE SURVEY" WAS PERFORMED BY ME OR UNDER MY DIRECT SUPERVISION, ON THE GROUND OF THE PROJECT AREA. THIS MAP DOES NOT CONSTITUTE A BOUNDARY SURVEY. NO TITLE REPORT WAS PROVIDED, AND NO ADDITIONAL EASEMENT RESEARCH WAS PREFORMED. THE PURPOSE OF THIS SURVEY IS TO SUPPORT THE PROPOSED COMMUNICATION FACILITIES. IT DEPICTS EXISTING, READILY VISIBLE IMPROVEMENTS, PUBLIC UTILITIES AND REPRESENTS THE PUBLIC RIGHT-OF-WAY SHOWN HERON FROM COUNTY GIS MAPPING OR RECORD INFORMATION. THE GEODETIC COORDINATES REPORTED HEREON ARE ACCURATE AND MEET FAA/FCC REPORTING REQUIREMENTS FOR A 1A CERTIFICATE OF: FIFTEEN FEET (15') HORIZONTALLY AND THREE FEET (3') VERTICALLY. R O N A L D M . H O D G E Site Plan_Antenna Info.pdfA9Rwshk5e_6ckooq_2qk.tmp ACHD PROJECT RF1 ANTENNA INFORMATION 0° 45° 90° 135° 180° 315° 270° 225° RAD CENTER NEW ANTENNA SCHEDULE AZIMUTH QTY. MFG. MODEL COAX SIZE (NOMINAL) TILT ELEC MECHCOAX CABLE LENGTH REFER TO VZW THE MOST RECENT RF CONFIGURATION SHEETS TO CONFIRM ANTENNA MODEL/TYPE AS WELL DOWNTILTS AND ADDITIONAL INFORMATION Site Plan_Details C300.pdfA9Rwshk5e_6ckooq_2qk.tmp C300 DETAILS ACHD PROJECT Site Plan_Details C301.pdfA9Rwshk5e_6ckooq_2qk.tmp ACHD PROJECT C301 DETAILS Site Plan_Details C302.pdfA9Rwshk5e_6ckooq_2qk.tmp ACHD PROJECT C302 DETAILS Site Plan_Electrical Notes.pdfA9Rwshk5e_6ckooq_2qk.tmp ACHD PROJECT E300 ELECTRICAL NOTES Site Plan_Enlarged Site Plan.pdfA9Rwshk5e_6ckooq_2qk.tmp ACHD PROJECT ENLARGED SITE PLAN 1 C101 ENLARGED SITE PLAN Site Plan_Grounding Site Plan.pdfA9Rwshk5e_6ckooq_2qk.tmp ACHD PROJECT GROUNDING PLAN 1 E100 GROUNDING SITE PLAN G G G G G G G G G G Site Plan_One-Line, Ground Rod, Trenching.pdfA9Rwshk5e_6ckooq_2qk.tmp ACHD PROJECT E200 TRENCHING ONE-LINE DIAGRAM, GROUND ROD AND Site Plan_Overall Site Plan.pdfA9Rwshk5e_6ckooq_2qk.tmp ACHD PROJECT OVERALL SITE PLAN 1 C100 OVERALL SITE PLAN ACHD MORATORIUM NOTE: THERE ARE NO RESTRICTIONS AT THIS TIME. S. MERIDIAN RD. W. OVERLAND RD. DESCRIPTION EQUIPMENT VOLUME TABLE INCLUDES: VOLUME (CU.FT.) Site Plan_Pole Site Survey.pdfA9Rwshk5e_6ckooq_2qk.tmp 21.7' (AGL) GRADE/SIDEWALK 2621.5' 40.6' (AGL) TOP OF POLE 16.1' (AGL) 13.1' (AGL) 8.8' (AGL) 39.7' (AGL) 0.7' (AGL) 34.6' (AGL) 43.9' (AGL)CAMERA 38.0' (AGL)LIT C C C C C C C C C C C C P P P P P P P P P P P P P P P P P P P P P P P P P C C C C C C C C C C C C C C C C C C C C C C C C C P P P P P P P P P P P P P P P P P P P P P P P R/W R/W R/W R/W R/W R/W R/W R GS GS GS GS GS GS GS GS GS GS GS WALGREENS M 8' JB JBJB JB JB JB JB JB PEDESTRIAN POLE PEDESTRIAN POLE SIGNAL CONTROL BOXES C C C C C C C ACHD P P P P P P CCCCCCCCCCCCCC ACHD ACHD ACHD PPPPPPPPPPPPP ACHD ACHD C C C ACHD IDAHO POWER SD SD SD SD SD SD SD SD SD SD SD SD SD SD SDACHD C C C C C C C C C C C C C C C C C CCCC CENTURYLINK CENTURYLINK 1625 S MERIDIAN ROAD MERIDIAN, IDAHO 83642 FOR INFORMATIONAL PURPOSES ONLY ORIGINAL SIGNED BY: RONALD M. HODGE, PLS DATE ORIGINAL SIGNED: 01-23-2019 ORIGINAL ON FILE AT THE OFFICE OF FOX LAND SURVEYS, INC. SCALE 1"=20' (11x17) SCALE 1"=10' (22x34) AFIELD SURVEYED ON01-14-19JRRMH B1-A CERTIFICATION SURVEY WITHOUT UTILITY LOCATES01-18-19TRCRMH UTILITY LOCATION NOTE THE UTILITY LINES SHOWN ON THIS DRAWING WERE DEVELOPED FROM SURFACE EVIDENCE AND LOCATION MARKS. MAPS WERE PROVIDED BY THE UTILITY COMPANIES SHOWN. GEM STATE LOCATING, INC. WAS CONTRACTED TO PROVIDED LOCATION MARKS BASED UPON THOSE MAPS. THE SURVEYOR DOES NOT GUARANTY OR WARRANTY THAT ALL UTILITY LINES ARE SHOWN OR THEIR LOCATION DEFINATE. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION AND DEPTH PRIOR TO CONSTRUCTION. CALL DIGLINE, INC. PRIOR TO ANY EXCAVATION. LATITUDE: LONGITUDE: GROUND ELEVATION: STRUCTURE HEIGHT (AGL): TALLEST APPURTENANCE HEIGHT (AGL): FAA-FCC 1A GEODETIC COORDINATES (83/88) 43°35'23.70" N 116°23'38.42" W 2622' 799.2m 41' 44' BASIS OF GEODETIC COORDINATES: (1) THE GEODETIC COORDINATES SHOWN HEREON WERE DERIVED FROM THE NATIONAL GEODETIC SURVEY (OPUS) UTILITY VIA STATIC GPS OBSERVATIONS UPON THE PROJECT CONTROL POINT. ALL SUBSEQUENT OBSERVATIONS WERE PROCESSED USING THE MICRO-SURVEY STAR*NET-PRO UTILITY AND/OR OTHER SOFTWARE UTILITIES. (2) HORIZONTAL DATUM: THE NORTH AMERICAN DATUM OF 1983 (NAD83)(2011)(EPOCH 2010) IS EXPRESSED IN DEGREES (°) MINUTES (') AND SECONDS (") AND ARE SHOWN TO THE 100TH OF A SECOND. (3) VERTICAL DATUM: THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88) (GEOID 12B) IS EXPRESSED IN U.S. SURVEY FEET AND IN METERS. C100% FINAL SURVEY FOR CLIENT, FRANCHISEE & AGENCY APPROVALS01-25-19TRCRMH SHEET NAME POLE SITE SURVEY 5 0 10 20 DWG: 19009-01MSFLSI PROJ#: 19009-01 DATEBYCHK THESE DRAWINGS AND SURVEYS ARE COPYRIGHT PROTECTED AND THE SOLE PROPERTY OF FOX LAND SURVEYS INC. AND PRODUCED FOR THE USE OF OUR CLIENT. ANY REPRODUCTION OR USE OF THE INFORMATION CONTAINED WITHIN SAID DOCUMENTS IS PROHIBITED WITHOUT THE WRITTEN CONSENT BY FOX LAND SURVEYS INC. 1515 S. Shoshone Street, Boise, Idaho 83705 www.foxlandsurveys.com Tel: 208-342-7957 DESIGNED FOR: DESCRIPTION SU - 2 10" LIGHT POLE ON 2' DIA CONC BASE VALVEv FIRE HYDRANT IRRIGATION BOX TREE, TRUNK DIAMETER IN INCHES, CANOPY DRAWN TO SCALE CATCH BASIN MAIL BOX BOLLARD MB COMMUNICATIONS RISER EDGE OF PAVEMENTEP EP EP EP R/W RIGHT-OF-WAY WATER LINEW W W W C C C C COMMUNICATIONS LINE OVERHEAD POWER LINEOHP OHP OHP CENTER LINE POWER LINEP P P P EDGE OF GRASSGS GS GS GS EDGE OF GRAVELEG EG EG EG SD SD SD SD STORM DRAIN LINE S S S S SEWER LINE G G G G GAS LINE PAINT STRIPE EDGE OF DIRT ROADRD RD RD RD GEO-THERMO LINEGEO GEO GEO AS ASPHALTIC SURFACE BLD BUILDING CONC CONCRETE SURFACE GVL GRAVEL GRS GRASS PLT PLANTER NTS NOT TO SCALE UTILITY POLE SIGN P MANHOLE M METER UTILITY POLE (DIP POLE) UTILITY POLE WITH TRANSFORMERPx GUY ANCHOR JB JUNCTION BOX TRAFFIC SIGNAL ARM STREET LIGHT ARM Pd B SURVEYOR'S CERTIFICATION: I RONALD M. HODGE, IDAHO PLS 8575, HEREBY CERTIFY TO TECHNOLOGY ASSOCIATES EC AND VERIZON WIRELESS: THAT THIS "POLE SITE SURVEY" WAS PERFORMED BY ME OR UNDER MY DIRECT SUPERVISION, ON THE GROUND OF THE PROJECT AREA. THIS MAP DOES NOT CONSTITUTE A BOUNDARY SURVEY. NO TITLE REPORT WAS PROVIDED, AND NO ADDITIONAL EASEMENT RESEARCH WAS PREFORMED. THE PURPOSE OF THIS SURVEY IS TO SUPPORT THE PROPOSED COMMUNICATION FACILITIES. IT DEPICTS EXISTING, READILY VISIBLE IMPROVEMENTS, PUBLIC UTILITIES AND REPRESENTS THE PUBLIC RIGHT-OF-WAY SHOWN HERON FROM COUNTY GIS MAPPING OR RECORD INFORMATION. THE GEODETIC COORDINATES REPORTED HEREON ARE ACCURATE AND MEET FAA/FCC REPORTING REQUIREMENTS FOR A 1A CERTIFICATE OF: FIFTEEN FEET (15') HORIZONTALLY AND THREE FEET (3') VERTICALLY. ACHD MORATORIUM NOTE: THERE ARE NO RESTRICTIONS AT THIS TIME. R O N A L D M . H O D G E RECORD MAP FACILITY CONTACTS UTILITY COMPANY CONTACT EMAIL ADDRESS PHONE FACILITIES Ada County Highway District Steven Pecka specka@achdidaho.org (208) 387-6258 YES ACHD Conduits Brock Love Blove@achdidaho.org YES Cable One Brett Pike brett.pike@cableone.biz YES CenturyLink Shelline Williamson Shelline.williamson@centurylink.com YES City of Meridian Al Christy Achristy@meridiancity.org YES Idaho Power Company Ethan Morgan UtilityLocationMap@idahopower.com (208) 388-6510 YES Intermountain Gas Bryce Ostler Bryce.ostler@intgas.com (208) 377-6812 YES Syringa Networks GIS Department gis@syringanetworks.net (800) 454-7214 YES Site Plan_Project Notes.pdfA9Rwshk5e_6ckooq_2qk.tmp ACHD PROJECT C303 PROJECT NOTES Site Plan_Specifications.pdfA9Rwshk5e_6ckooq_2qk.tmp ACHD PROJECT RF2 SPECIFICATIONS Site Plan_Title Sheet, Vicinity Map, General Info.pdfA9Rwshk5e_6ckooq_2qk.tmp TITLE SHEET VICINITY MAP GENERAL INFORMATION T100 ACHD PROJECT R E V REV DATE SITE Vicinity Map_BOI Roaring Walowes SC.pdfFull page photo