Loading...
Landscape PlanRI S E R T E L ECONCONCONCONCONCONCONCONCONCONCONCON T T T T TTTTT TTTTTTTTTTTTELEC ELEC ELEC ELEC KEY NOTES PROTECT EXISTING TREE IN PLACE. SEE CIVIL FOR DETENSION BASIN ROCK REQUIREMENTS. EXISTING UTILITY, SEE CIVIL FOR MORE INFORMATION. 1 01SITE LANDSCAPE PLAN SCALE: 1" = 30'-0" 15'30'60' 1.SEE SHEET EM-G-0002 FOR GENERAL CONSTRUCTION NOTES 2.ALL LANDSCAPE AND PLANT MATERIALS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE AMERICAN STANDARDS FOR NURSERY STOCK, ANSI Z60.1. PROVIDE HEALTHY PLANT MATERIALS AS SPECIFIED. 3.GRADING SHALL BE ACCEPTED PRIOR TO PLANT INSTALLATION. CONTRACTOR SHALL AMEND PLANT BED SOIL AND SHAPE GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DISPOSING OF ALL DEBRIS AND EXCESS SOIL OCCASIONED BY THIS PROJECT IN THE PLANT BED AREA. 4.PRIOR TO PLANTING, IRRIGATION SYSTEM SHALL BE FULLY OPERATIONAL. CONTRACTOR SHALL INSTALL IRRIGATION SYSTEM TO PROVIDE A COMPLETE SYSTEM WITH UNIFORM COVER TO ALL NEW PLANTINGS. THOROUGHLY WATER ALL PLANTED AREAS IMMEDIATELY AFTER PLANTING. 5.ADJUST PLANTING LOCATIONS IF THEY CONFLICT WITH EXISTING UTILITIES. CONTRACTOR SHALL BE RESPONSIBLE FOR UTILITY LOCATIONS AND PROTECTION DURING INSTALLATION OF PLANT MATERIALS AND IRRIGATION SYSTEM. 6.REFER TO ENGINEERING DRAWINGS FOR FURTHER INFORMATION REGARDING CIVIL MATTERS. 7.DISCREPANCIES BETWEEN PLANS AND SITE CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER PRIOR TO PROCEEDING. GENERAL NOTES LANDSCAPE PLANEM-L-1001 0 CARIZMENDEZREVDESCRIPTIONDATEBOISEFACILITIESENGINEERINGPROJECT COORD: ENG. COORD: OWNER: DRAWN BY: LID: TOOL ETI: TOOL MICAP: NOTE THIS DOCUMENT IS THE PROPERTY OF MICRON TECHNOLOGY, INC. AND CONTAINS CONFIDENTIAL INFORMATION THAT IS PROTECTED BY A CONFIDENTIALITY OR NON DISCLOSURE AGREEMENT EXECUTED BY THE RECIPIENT, AND STATE AND FEDERAL LAW. UNAUTHORIZED DISCLOSURE MAY RESULT IN CIVIL OR CRIMINAL LIABILITY. ISSUED FOR CONSTRUCTION SIGNATURE REVISION SHEET PROJECT / WO:DOCUMENTPROJECTC39982 CRUCIAL EXTERIOR MODIFICATIONS - FINISHED GOODS TO R&D SUPPORT SSCHELLER PCHRISTENSEN JFIESELMAN APPROVED FOR CONSTRUCTION (APPROVER)(DATE)0ISSUE FOR CONSTRUCTION2/6/2020A99% BID SET1/24/2020PLANT LEGEND SYMBOL COMMON NAME BOTANICAL NAMEQUANTITY LANDSCAPE LEGEND SYMBOL DESCRIPTION NOTESQUANTITY 13,500 SQUARE FEET DECORATIVE ROCK COLOR: BLACK AND TAN SIZE: 1" - 1 1 2" (NO FINES) 12 19 8 4 6 CANADA RED CHOKECHERRY HOT WINGS TATARIAN MAPLE CRIMSON SPIRE OAK VANDERWOLF'S PYRAMID LIMBER PINE SKYROCKET JUNIPER SIZE 2" CALIPER SINGLE STEM 2" CALIPER SINGLE STEM 2" CALIPER 6' HEIGHT 6' HEIGHT 1 TREE QUANTITY WEST PROPERTY LINE 145' LENGTH 4 TREES REQUIRED 4 TREES PROVIDED SOUTH PROPERTY LINE 645' LENGTH 18 TREES REQUIRED 18 TREES PROVIDED (INCLUDES EXISTING TREE) EAST PROPERTY LINE 145' LENGTH 4 TREES REQUIRED 4 TREES PROVIDED PARKING LOT ISLANDS 24 TREES REQUIRED (2 PER ISLAND SERVING DOUBLE PARKING STALLS) 24 TREES PROVIDED 57 52 SUMMER WINE NINEBARK WINE & ROSES WEIGELA 2 GALLON CONTAINER 2 GALLON CONTAINER TREE SHRUB 3" DEPTH PROPERTY LINE BUFFER & PARKING ISLANDS CITY OF MERIDIAN LANDSCAPE BUFFER (PARKING LOT) REQUIREMENTS SHRUB QUANTITY AS NEEDED TO PROVIDE 70% COVERAGE AT MATURITY IN REQUIRED LANDSCAPE PARKING LOT AND BUFFER AREAS PRUNUS VIRGINIANA 'CANADA RED' ACER TATARICUM 'HOT WINGS' QUERCUS ROBUR X ALBA 'CRIMSHMIDT' PINUS FLEXIS 'VANDERWOLF'S PYRAMID' JUNIPERUS SCOPULORUM 'SKYROCKET' PHYSOCARPUS OPULIFOLIUS 'SEWARD' WEIGELA FLORIDA 'ALEXANDRA' NOTES PRUNE TO MINIMUM CLEAR BRANCH HEIGHT OF 6' AT INSTALL. PRUNE TO MINIMUM CLEAR BRANCH HEIGHT OF 8' AT MATURITY PRUNE TO MINIMUM CLEAR BRANCH HEIGHT OF 6' AT INSTALL. PRUNE TO MINIMUM CLEAR BRANCH HEIGHT OF 8' AT MATURITY GROUNDCOVER 48 PANCHITO MANZANITA 2 GALLON CONTAINERARCTOSTAPHYLOS X COLORADENSIS ' PANCHITO' 2 2 2 3 3 X 5' TYP. BUFFER A.C.A.C.A.C. ELEC ELEC ELEC ELEC 0.771 1" 1.302 1" 0.873 1" 1.324 1" EC SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY SHRUB IRRIGATOR ASSEMBLY (2) 0.5 GPH DRIP EMITTERS PER SHRUB 157 TREE IRRIGATOR ASSEMBLY (4) 0.5 GPH DRIP EMITTERS 49 SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY RAIN BIRD PESB VALVE 1". LOW FLOW OPERATING CAPABILITY, GLOBE CONFIGURATION, SCRUBBER TECHNOLOGY, AND INLINE FILTER. 4 EXISTING BACKFLOW PREVENTER (FEBCO 825Y) 1" EXISTING REDUCED PRESSURE BACKFLOW PREVENTER - RAIN BIRD ESP8LXME-LXMM 8 STATION CAPABLE COMMERCIAL CONTROLLER. MOUNTED ON A POWDER COATED GRAY METAL CABINET. 1 EXISTING POINT OF CONNECTION 3/4"- IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21 4,450 L.F. IRRIGATION MAINLINE: PVC SCHEDULE 40 CONTROL WIRE CONDUIT: PVC SCHEDULE 40 300 L.F. PIPE SLEEVE: PVC SCHEDULE 40 WIRE SLEEVE: PVC SCHEDULE 40 550 L.F. EACH AIR RELIEF VALVE SEE DETAIL MANUAL DRAIN VALVE SEE DETAIL 4 4 IRRIGATION SCHEDULE EXISTING MAINLINE - 1,100 L.F. EC EXISTING CONTROLLER - 01SITE IRRIGATION PLAN SCALE: 1" = 30'-0" 15'30'60' KEY NOTES CONNECT TO EXISTING MAINLINE INSTALL NEW CONTROLLER ADJACENT TO THE EXISTING CONTROLLER. APPROXIMATE EXISTING CONTROLLER LOCATION. APPROXIMATE EXISTING MAINLINE. EXISTING P.O.C. AND BACKFLOW ASSEMBLY. NEW CONTROL WIRE FROM NEW CONTROLLER TO FOLLOW EXISTING MAINLINE. PROTECT EXISTING TREE. 1 1.SEE SHEET EM-G-0002 FOR GENERAL CONSTRUCTION NOTES. 2.CONTRACTOR TO VERIFY EXISTING IRRIGATION SYSTEM LAYOUT, PRESSURES, AND FLOW. NOTIFY OWNER IF DISCREPANCY FOUND. 3.EXISTING IRRIGATION MANUFACTURER AND SIZES PROVIDED BY OWNER - SEE TABLE. 4.THE PROPOSED IRRIGATION DESIGN ASSUMES THE EXISTING MAINLINE IS LOCATED NEAR THE SOUTH END OF THE BUILDING ON BOTH SIDES FOR A NEW MAINLINE CONNECTION. 5.SIZE IRRIGATION PIPES TO RESTRICT WATER FLOW TO A MAXIMUM OF 5 FEET PER SECOND. 6.CONTRACTOR TO LOCATE UTILITIES PRIOR TO DIGGING. 7.NO ROCKS, BOULDERS, OR OTHER EXTRANEOUS MATERIALS TO BE USED IN BACKFILLING OF TRENCHES. 8.ALL PIPE AND PIPE CONNECTIONS TO BE INSTALLED AS PER MANUFACTURER'S SPECIFICATIONS. 9.ALL EQUIPMENT NOT SPECIFIED ON THE LEGEND SHALL BE DETERMINED, SUBMITTED IN SHOP DRAWING SUBMITTALS, AND FURNISHED BY THE CONTRACTOR. 10.VALVE CONTROL WIRES SHALL BE COLOR CODED; COMMON-WHITE, CONTROL-RED. 11.IRRIGATION DESIGN SHOWN ON THIS PLAN IS SCHMEMATIC. PLACE ALL IRRIGATION EQUIPMENT WITHIN PLANTER BEDS. GENERAL NOTES SITE IRRIGATION PLANEM-L-1002 0 CARIZMENDEZREVDESCRIPTIONDATEBOISEFACILITIESENGINEERINGPROJECT COORD: ENG. COORD: OWNER: DRAWN BY: LID: TOOL ETI: TOOL MICAP: NOTE THIS DOCUMENT IS THE PROPERTY OF MICRON TECHNOLOGY, INC. AND CONTAINS CONFIDENTIAL INFORMATION THAT IS PROTECTED BY A CONFIDENTIALITY OR NON DISCLOSURE AGREEMENT EXECUTED BY THE RECIPIENT, AND STATE AND FEDERAL LAW. UNAUTHORIZED DISCLOSURE MAY RESULT IN CIVIL OR CRIMINAL LIABILITY. ISSUED FOR CONSTRUCTION SIGNATURE REVISION SHEET PROJECT / WO:DOCUMENTPROJECTC39982 CRUCIAL EXTERIOR MODIFICATIONS - FINISHED GOODS TO R&D SUPPORT SSCHELLER PCHRISTENSEN JFIESELMAN APPROVED FOR CONSTRUCTION (APPROVER)(DATE)0ISSUE FOR CONSTRUCTION2/6/2020A99% BID SET1/24/20201 1 2 2 3 3 4 4 6 4 6 5 4 5 6 7 X 7 MAINLINE: 1" SCHEDULE 40 PVC LATERALS: CLASS 200 WATER METER: 3/4" SIZE STATIC PSI: 40 PSI BACKFLOW PREVENTER: WILKINS 1 1/2" CONTROLLER: LOCATED AT NORTH SIDE OF BUILDING VALVE OPERATION: ONE VALVE AT A TIME EXISTING IRRIGATION ASSUMPTIONS PLANTING DETAILSEM-L-3001 0 CARIZMENDEZREVDESCRIPTIONDATEBOISEFACILITIESENGINEERINGPROJECT COORD: ENG. COORD: OWNER: DRAWN BY: LID: TOOL ETI: TOOL MICAP: NOTE THIS DOCUMENT IS THE PROPERTY OF MICRON TECHNOLOGY, INC. AND CONTAINS CONFIDENTIAL INFORMATION THAT IS PROTECTED BY A CONFIDENTIALITY OR NON DISCLOSURE AGREEMENT EXECUTED BY THE RECIPIENT, AND STATE AND FEDERAL LAW. UNAUTHORIZED DISCLOSURE MAY RESULT IN CIVIL OR CRIMINAL LIABILITY. ISSUED FOR CONSTRUCTION SIGNATURE REVISION SHEET PROJECT / WO:DOCUMENTPROJECTC39982 CRUCIAL EXTERIOR MODIFICATIONS - FINISHED GOODS TO R&D SUPPORT SSCHELLER PCHRISTENSEN JFIESELMAN APPROVED FOR CONSTRUCTION (APPROVER)(DATE)0ISSUE FOR CONSTRUCTION2/6/2020A99% BID SET1/24/2020SCALE: NONE 6TREE PLANTING SCALE: NONE 3SHRUB PLANTING WOOD STAKES DO NOT DRIVE INTO ROOTBALL REMOVE AT END OF PLANT ESTABLISHMENT PERIOD. RAINWATER BASIN FORMED AS 4"-6" DEPTH DEPRESSION AROUND TREE EXISTING GRADE FLOW TOPSOIL DO NOT INSTALL ROOTBOUND PLANTS. PULL MULCH MATERIAL AWAY FROM TRUNK 3" DEPTH DECORATIVE ROCK GENTLY LOOSEN ROOTS AROUND EXTERIOR OF ROOTBALL.. SET ROOTBALL ON UNDISTURBED OR FIRMLY PACKED SOIL PLANTING PIT 5' MIN. DIAMETER FLOW PLANTING PIT. 24" MIN. DIAMETER 18" MIN. PULL MULCH MATERIAL AWAY FROM TRUNK 3" DEPTH DECORATIVE ROCK MULCH SIDES OF PIT SHALL BE RAKED TO LOOSEN PRIOR TO SETTING PLANTS IN PLACE GENTLY LOOSEN ROOTS AROUND EXTERIOR OF ROOTBALL. DO NOT PRUNE PLANTS WITHOUT LANDSCAPE ARCHITECT APPROVAL DIRECTION. SET ROOTBALL ON UNDISTURBED OR FIRMLY PACKED SOIL DO NOT INSTALL ROOTBOUND PLANS TOPSOIL RAINWATER BASIN FORMED AS 4"-6" DEPTH DEPRESSION AROUND SHRUB SIDES OF PIT SHALL BE RAKED TO LOOSEN PRIOR TO SETTING PLANTS IN PLACE 8.5" X 11" SIGN LAMINATED IN PLASTIC SPACED EVERY 50' ALONG THE FENCE 4'-0"TREE PROTECTION FENCE: HIGH DENSITY POLYETHYLENE FENCING WITH 3.5" X 1.5" OPENINGS; COLOR-ORANGE. STEEL POSTS INSTALLED AT 8' O.C. 2" X 6' STEEL POSTS OR APPROVED EQUAL 5" THICK LAYER OF ORGANIC MULCH MAINTAIN EXISTING GRADE WITH THE TREE PROTECTION FENCE UNLESS OTHERWISE INDICATED ON THE PLANS KEEP OUT TREE PROTECTION AREA CROWN DRIP LINE OR OTHER LIMIT OF TREE PROTECTION AREA. NOTES: 1.NO PRUNING SHALL BE PERFORMED EXCEPT BY APPROVED ARBORIST. 2.NO EQUIPMENT SHALL OPERATE INSIDE THE PROTECTIVE FENCING INCLUDING DURING FENCE INSTALLATION AND REMOVAL. 3.DEEP WATER TREE PRIOR TO FENCE INSTALLATION. WATER AS NECESSARY DURING CONSTRUCTION. SCALE: NONE 2TREE PROTECTIONFENCING CURB 18" DEEP LINEAR ROOT BARRIER. (SEE SPECIFICATIONS). TAMP SOIL ADJACENT TO ROOT BARRIERS TO STABILIZE. 8' MIN. TOP OF ROOT BARRIER FLUSH WITH FINISHED GRADE. CURB FINISHED GRADE 2" BELOW ADJACENT PAVEMENT EXISTING SOIL PLAN VIEW 18" DEEP LINEAR ROOT BARRIER NOTES: 1.ROOT BARRIERS SHALL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS. SCALE: NONE 1ROOT BARRIERS -PARKING LOT ISLANDS SCALE: NONE 5 TREE PLANTING - WOOD STAKES DO NOT DRIVE INTO ROOTBALL REMOVE AT END OF PLANT ESTABLISHMENT PERIOD. CURB TOPSOIL DO NOT INSTALL ROOTBOUND PLANTS. PULL MULCH MATERIAL AWAY FROM TRUNK 3" DEPTH DECORATIVE ROCK MULCH GENTLY LOOSEN ROOTS AROUND EXTERIOR OF ROOTBALL.. SET ROOTBALL ON UNDISTURBED OR FIRMLY PACKED SOIL PLANTING PIT 5' MIN. DIAMETER 24" MIN. SIDES OF PIT SHALL BE RAKED TO LOOSEN PRIOR TO SETTING PLANTS IN PLACE PARKING ISLAND CURB FENCE3" DEPTH DECORATIVE ROCK MULCH 24" MIN. TREE STAKES PLACED 2" BELOW SURFACE SUBGRADE UNDER ROOTBALL TO BE KEPT UNDISTURBED TO REDUCE SETTLING OR COMPACT TOPSOIL TO PROVIDE A FIRM BASE TO PREVENT SETTLEMENT1/2 HEIGHT OF TREEREMOVE WIRE BASKET AND/OR BURLAP COMPLETELY GUY WIRE SCALE: NONE 4 TREE PLANTING -EVERGREEN TREE AT TIME OF PLANTING TRIM ONLY DEAD, BROKEN AND DOUBLE LEADER BRANCHES REMOVE ALL TREE WRAP FLAGGING 10" SQ MIN. ROOT FLARE SHALL BE 1" TO 2" ABOVE FINISH GRADE. REMOVE EXCESS SOIL FROM ROOT BALL AS REQUIRED TO EXPOSE ORIGINAL ROOT FLARE 3" DEPTH DECORATIVE ROCK MULCH - KEEP BACK FROM TRUNK BACKFILL WITH TOP SOIL - WATER IN 6" LAYERS, DO NOT TAMP PLANTING PIT 5' MIN. DIAMETER