Second Floor PlanF.E.C.F.E.C.1t WINDOW FRAME TYPE - SEE SHEET A3.00
#VAT TUBE IDENTIFICATION.
CONFIRM WITH OWNER PRIOR TO
INSTALLATION
DOOR WITH HANDICAP ACTUATOR*
WALL TYPE - SEE SHEET A3.101i
BRICK VENEER CONTROL JOINT LOCATION,
SEE DETAIL A1/A5.1.
CJ
ELEV
11,300 SF SECOND LEVEL
3' - 0"
3' - 0"
B1
A4.10
B1
A4.10
C1
A4.10
C1
A4.10
D1
A4.10
D1
A4.10
AA
BB
CC
DD
EE
FF
GG
1
1
2
2
3
3 4
4
5
5 6
6
7
7
8
8
159' - 7"
A9.10
B4
A9.20
B4
STAIR #1
200
HALL
201
HALL
203
MENS
204
WOMENS
205
JANITOR
206
ELEC.
207
HALL
208
STAIR #2
210
ROOF
BELOW
ROOF
BELOW
ROOF
BELOW
11' - 4"31' - 4"8' - 11" 27' - 1"20' - 0"29' - 7"31' - 4"
11' - 4" 6' - 0" 13' - 4" 12' - 0" 3' - 1" 5' - 10" 27' - 1" 7' - 9" 12' - 3"29' - 7"31' - 4"100' - 0"10' - 8" 19' - 2"28' - 0"12' - 10" 15' - 2" 14' - 2"
11' - 4"31' - 4"8' - 11" 27' - 1"20' - 0"29' - 7"31' - 4"
159' - 7"
11' - 4" 9"39' - 6"21' - 1" 6' - 0" 20' - 0"29' - 7"31' - 4"100' - 0"10' - 8" 19' - 2"28' - 0"12' - 10" 15' - 2" 14' - 2"11" 9' - 9" 19' - 2"28' - 0"12' - 10" 1 1/2" 15' - 0 1/2" 2' - 11 3/8" 11' - 2 5/8"
A6.00
D3
C4
A4.10
D1
A9.10
A9.30
C5
D3
A5.00
128" 230"336"154" 182" 170"
136"376"107" 325"240"355"376"56' - 0"4830 SF
TENANT 1
202
3741 SF
TENANT 2
209
202A
209A
204
205
206 207
209B
202B
210
104413.A2
104413.A2
13' - 2"5' - 2"12' - 10"17' - 11"10' - 1"1' - 9"4' - 4" 4' - 7" 16' - 9" 3' - 2"
17' - 7"
1' - 7"
65123
B
C
4
A
D
651234
JOB N0.:
CHECKED BY:
SHEET NO.
DRAWN BY:
DATE:
PHASE:
CONSULTANT:
COPYRIGHT All rights reserved. Reproduction or use in any form
or by any means -- graphic, electronic, mechanical, etc. -- without
written permission of LOMBARD - CONRAD ARCHITECTS, P.C.
is unlawful and subject to criminal prosecution.
STAMP:
TEN MILE
BRANCH
SECOND FLOOR
PLAN
A2.11
19230.01
Author
Checker
05/29/20
IDAHO CENTRAL
CREDIT UNION
N1/8" = 1'-0"D1 SECOND FLOOR PLAN MRKDATEDESCRIPTION1. EXTERIOR DIMENSIONS ARE TO GRID, FACE OF FOUNDATION,
CENTERLINE OF COLUMN OR ROUGH OPENING UNLESS OTHERWISE
NOTED. SEE WALL SECTIONS FOR RELATIONSHIP OF
FRAMING/FINISHES TO FACE OF FOUNDATION.
2. INTERIOR DIMENSIONS ARE TO CENTERLINE OF COLUMN OR
CENTERLINE OF WALL STUD UNLESS OTHERWISE NOTED.
3. ALL INTERIOR WALLS SHALL EXTEND FROM FINISH FLOOR TO
BOTTOM OF STRUCTURE UNLESS NOTED OTHERWISE.
4. FOR ALL SHEAR WALLS, THE SIDE OF THE WALL ON WHICH THE WALL
TAG IS LOCATED IS THE SIDE OF THE WALL ON WHICH THE
SHEATHING IT SO BE APPLIED.
5. SEE SHEET A3.00 FOR DOOR AND WINDOW ELEVATIONS.
6. BLOCKING AT ALL WALLS SHALL BE AT 10'-0" A.F.F., CEILING LINES
AND AS PER 2015 IBC AS REQUIRED.
7. ALL SILL PLATES SHALL BE PRESSURE TREATED.
8. SEE ROOM FINISH SCHEDULE SHEET A2.12 FOR FLOOR FINISH
INFORMATION.
9. SEE CIVIL AND LANDSCAPE DRAWINGS FOR RELATIONSHIP OF SITE
WORK TO BUILDING.
10. PROVIDE SOUND ATTENUATION INSULATION (092900) AT ALL
INTERIOR WALLS FROM FLOORS TO DECK U.O.N.
11. REFER TO WALL SECTIONS FOR EXTERIOR WALL REQUIREMENTS.
SEE DETAILS B1/A8.0 FOR TYPICAL FIXTURE MOUNTING AND ADA
REQUIREMENTS.
GENERAL NOTES
KEYNOTES#
LEGEND
104413.A2 SEMI-RECESSED FIRE-PROTECTION CABINET.
1. JANITOR'S SINK AND MOP SHELF. SEE MECHANICAL FOR SINK
INSTALLATION.
CONDOC