Loading...
PZ - Landscape Plans F E 0 ao COMMON EARTHWORK NOTES IRRIGATION NOTES PLANTING NOTES: z L_ a) 3 1. VERIFICATION OF CONDITIONS: 7. DELIVERY, STORAGE,AND HANDLING: ao u N 1. BEFORE PROCEEDING WITH WORK, CHECK AND VERIFY o A. FORTY-EIGHT(48) HOURS MINIMUM BEFORE DIMENSIONS AND QUANTITIES. REPORT VARIATIONS A. DELIVERY AND ACCEPTANCE REQUIREMENTS: 10. PLANTING: 1. FURNISH AND INSTALL LANDSCAPE IRRIGATION SYSTEM AS 6. REGULATORY REQUIREMENTS: 15.INSTALLATION OF PIPE: � -E- � PERFORMING ANY WORK ON SITE, CONTACT THE BETWEEN DRAWINGS AND SITE TO LANDSCAPE ARCHITECT 1. DELIVER TREES, SHRUBS, GROUND COVERS,AND 1. REMOVING BINDERS AND CONTAINERS: DESCRIBED IN CONTRACT DOCUMENTS COMPLETE WITH A. WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH A. INSTALL PIPE IN MANNER TO PROVIDE FOR EXPANSION Im 3 •2 S PLANTS AFTER PREPARATIONS FOR PLANTING HAVE A. REMOVE TOP ONE/THIRD OF WIRE BASKET AND APPROPRIATE UNDERGROUND UTILITY SERVICE ACCESSORIES NECESSARY FOR PROPER FUNCTION. LATEST RULES AND REGULATIONS,AND OTHER AND CONTRACTION AS RECOMMENDED BY BEFORE PROCEEDING. c E u BEEN COMPLETED AND INSTALL IMMEDIATELY. BURLAP BINDERS. � � ECa AGENCY TO ARRANGE FOR UTILITY LOCATION APPLICABLE STATE OR LOCAL LAWS. MANUFACTURER. � L SERVICES. 2. PLANT TOTALS ARE FOR CONVENIENCE ONLY AND ARE NOT 2. DO NOT PRUNE BEFORE DELIVERY, EXCEPT AS B. REMOVE PLASTIC AND TWINE BINDERS FROM 2. FIELD TESTS AND INSPECTIONS: B. NOTHING IN CONTRACT DOCUMENTS IS TO BE B. UNLESS OTHERWISE INDICATED ON CONTRACT � o � B. PERFORM MINOR, INVESTIGATIVE EXCAVATIONS TO GUARANTEED. VERIFY AMOUNTS SHOWN ON CONTRACT APPROVED BY LANDSCAPE ARCHITECT. AROUND ROOT BALLANDTREE TRUNK. o 0 A. IRRIGATION SYSTEM: CONSTRUED TO PERMIT WORK NOT CONFORMING TO DRAWINGS, INSTALL MAIN LINES WITH MINIMUM COVER C VERIFY LOCATION OF VARIOUS EXISTING 1. SYSTEM PRESSURE TEST: THESE CODES. OF 18 INCHES (450 MM) BASED ON FINISHED GRADE. DOCUMENTS. ALL PLANTING INDICATED ON CONTRACT 3. PROTECT BARK, BRANCHES,AND ROOT SYSTEMS C. REMOVE PLASTIC CONTAINERS. r � p. '� FROM SUN SCALD, DRYING, WHIPPING,AND OTHER D. REMOVE WOOD BOXES FROM AROUND ROOT BALL. `n UNDERGROUND FACILITIES AT SUFFICIENT LOCATIONS a) NOTIFY LANDSCAPE ARCHITECT TWO (2)WORKING INSTALL LATERAL LINES, INCLUDING THOSE CONNECTING DOCUMENTS IS REQUIRED UNLESS INDICATED OTHERWISE. c N TO ASSURE THAT NO CONFLICT WITH THE PROPOSED DAYS MINIMUM BEFORE CONDUCTING TEST. 7. QUALIFICATIONS: DRIP TUBING, WITH MINIMUM OF 12 INCHES (300 MM)OF HANDLING AND TYING DAMAGE. REMOVE BOX BOTTOMS BEFORE POSITIONING PLANT o 4. DO NOT BEND OR BIND-TIE TREES OR SHRUBS IN IN HOLE. AFTER PLANT IS PARTIALLY PLANTED, V) C)WORK EXISTS AND SUFFICIENT CLEARANCE IS b) IN PRESENCE OF LANDSCAPE ARCHITECT, A. IRRIGATION SUBCONTRACTOR: COVER BASED ON FINISH GRADE. 3. LAYOUT INDIVIDUAL TREE AND SHRUB LOCATIONS AND ao C N SUCH A MANNER AS TO DESTROY NATURAL SHAPE. REMOVE REMAINDER OF BOX WITHOUT INJURING AVAILABLE TO AVOID DAMAGE TO EXISTING FACILITIES. PRESSURE TEST MAIN LINE WITH ALL VALVES 1. COMPANY SPECIALIZING IN PERFORMING WORK OF C. INSTALL PIPE AND WIRES UNDER DRIVEWAYS OR PARKING AREAS FOR MULTIPLE PLANTINGS: `0 INSTALLED. THIS SECTION. AREAS IN SPECIFIED SLEEVES 18 INCHES 450 MM BELOW 5. PROVIDE PROTECTIVE COVERING DURING DELIVERY. ROOT BALL. o ro J 'C C. PERFORM INVESTIGATIVE EXCAVATING TEN (10) DAYS ( ) A.STAKE LOCATIONS AND OUTLINE AREAS. 0_B. STORAGE AND HANDLING REQUIREMENTS; 2. PLANT IMMEDIATELY AFTER REMOVING BINDING C _ MINIMUM IN ADVANCE OF PERFORMING ANY c) TEST PRESSURE AT 100 PSI (690 KPA) MINIMUM FOR 2. MINIMUM FIVE (5)YEARS EXPERIENCE IN IRRIGATION FINISH GRADE OR AS SHOWN ON CONTRACT DRAWINGS. B.SECURE LANDSCAPE ARCHITECT'S APPROVAL BEFORE TWO (2) HOURS MINIMUM. w dS to EXCAVATION OR UNDERGROUND WORK. PLANTING. 1. HANDLE BALLED STOCK BY ROOT BALL OR MATERIALAND CONTAINERS: SPRINKLER INSTALLATIONS. D. LOCATE PIPE SO NO SPRINKLER HEAD WILL BE CLOSER J CONTAINER. DO NOT DROP TREES AND SHRUBS A. PLACE TREE AND SHRUB ROOT BALLS ON D. UPON DISCOVERY OF CONFLICTS OR PROBLEMS WITH d) VERIFY THERE ARE NO LEAKS. 3. MINIMUM FIVE (5)SATISFACTORILY COMPLETED THAN 12 INCHES (300 MM) FROM BUILDING FOUNDATION. C.MAKE MINOR ADJUSTMENTS AS MAY BE REQUESTED. N ;3 c • DURING DELIVERY. UNDISTURBED SOIL. v EXISTING FACILITIES, NOTIFYARCHITECT BY PHONE OR e) RECEIVE LANDSCAPE ARCHITECT APPROVAL TO IRRIGATION SPRINKLER INSTALLATIONS IN PAST E. CUT PLASTIC PIPE SQUARE. REMOVE BURRS AT CUT 0 r:+ PROCEED PRIOR TO BACKFILLING. THREE 3 YEARS OF PROJECTS SIMILAR IN SIZE, ENDS BEFORE INSTALLATION SO UNOBSTRUCTED FLOW 2. IF PLANTING IS DELAYED MORE THAN SIX HOURS B. AFTER WATERING AND SETTLING,TOP OF TREE ROOT bJD r FAX WITHIN TWENTY-FOUR (24) HOURS. FOLLOW ( ) 4. MAINTENANCE: AFTER DELIVERY, SET PLANTING MATERIALS IN BALLS SHALL BE APPROXIMATELY TWO INCHES (50 E ,__ TELEPHONE OR FAX NOTIFICATION WITH LETTER AND 2. TEST REPORT: SCOPE,AND COMPLEXITY REQUIRED FOR THIS WILL RESULT. A.GENERAL: M c SHADE AND PROTECT FROM WEATHER AND MM) HIGHER THAN FINISHED GRADE AND TRUNK L DIAGRAMS INDICATING CONFLICT OR PROBLEM AND a) FOLLOWING PRESSURE TEST, CREATE PRESSURE PROJECT BEFORE BIDDING. F. MAKE SOLVENT WELD JOINTS AS FOLLOWS: 1. BEFORE BEGINNING MAINTENANCE PERIOD, PLANTS c cn MECHANICAL DAMAGE. FLARE IS VISIBLE. SUFFICIENT MEASUREMENTS AND DETAILS TO TEST REPORT. DOCUMENT PRESSURE TEST 4. USE TRAINED PERSONNEL FAMILIAR WITH 1. DO NOT MAKE SOLVENT WELD JOINTS IF AMBIENT SHALL BE IN AT LEAST AS SOUND, HEALTHY, mi " o V 3. SET BALLED STOCK ON GROUND AND COVER BALL C. SHRUB ROOT BALLS SHALL BE APPROXIMATELY ONE EVALUATE PROBLEM. RESULTS THROUGH PROVIDING PHOTOS, LISTING REQUIRED IRRIGATION SPRINKLER PROCEDURES TEMPERATURE IS BELOW 35 DEG F (2 DEG C). VIGOROUS,AND IN APPROVED CONDITION AS WHEN cn N • PROCESSES USED, ISSUES ENCOUNTERED,AND AND WITH CONTRACT DOCUMENTS. 2. CLEAN MATING PIPE AND FITTING WITH CLEAN, DRY WITH SOIL, SAW DUST, OR OTHER ACCEPTABLE INCH (25 MM) HIGHER THAN FINISHED GRADE. 'dp DELIVERED TO SITE, UNLESS ACCEPTED BY MATERIAL APPROVED BY LANDSCAPE ARCHITECT. 3. PROPERLY CUT OFF BROKEN OR FRAYED ROOTS. MEASURES TAKEN TO CORRECT PROBLEMS. 5. FOREMAN OR SUPERVISOR REQUIRED TO ATTEND CLOTH AND APPLY ONE (1)COAT OF PRIMER TO EACH ARCHITECT IN WRITING AT FINAL LANDSCAPE W c bQ 2. PROTECTION: B. SUBSTANTIAL COMPLETION WALKTHROUGH: SITE MEETINGS. SURFACE. 4. DO NOT REMOVE CONTAINER-GROWN STOCK FROM 4. CENTER PLANT IN HOLE, REMOVE REMAINING WIRE u cn = W INSPECTION. A. SPILLAGE: CONTAINERS BEFORE TIME OF PLANTING. BASKET AND BURLAP TAKING CARE NOT DO DAMAGE 'L � 1. LANDSCAPE ARCHITECT OR DESIGNATED F. UPON REQUEST, SUBMIT DOCUMENTATION. 3. APPLY UNIFORM COAT OF SOLVENT CEMENT TO 2. MAINTAIN LANDSCAPING FOR THIRTY(30) L 1. AVOID SPILLAGE BY COVERING AND SECURING 5. DO NOT STORE PLANT MATERIAL ON PAVEMENT. ROOT BALL: E 4)REPRESENTATIVES)WILL INSPECT SITE AND CREATE B. IRRIGATION INSTALLER: OUTSIDE OF PIPE. CONTINUOUS DAYS MINIMUM AFTER SUBSTANTIAL ° jw LOADS WHEN HAULING ON OR ADJACENT TO PUBLIC 6. WATER ROOT SYSTEMS OF TREES AND SHRUBS A. REPLACE DAMAGED MATERIAL. c J LIST OF NON-CONFORMING ITEMS TO BE RESOLVED 1. PERFORM INSTALLATION UNDER DIRECTION OF 4. APPLY SOLVENT CEMENT TO FITTING IN SIMILAR COMPLETION. IF MAINTENANCE PERIOD IS o C U STREETS OR HIGHWAYS. PRIOR TO LANDSCAPE FINAL ACCEPTANCE. DATE ON FOREMAN OR SUPERVISOR. MANNER. STORED ON SITE WITH FINE SPRAY. WATER AS B. BACKFILL WITH SPECIFIED PLANTING MIX. w 2. REMOVE SPILLAGE AND SWEEP, WASH, OR INTERRUPTED BY NON-GROWING SEASON OR �r- THIS LIST WILL ACT AS DATE OF LANDSCAPE 2. MINIMUM THREE 3 YEARS EXPERIENCE IN IRRIGATION 5. INSERT PIPE COMPLETELY INTO FITTING. OFTEN AS NECESSARY TO MAINTAIN ROOT SYSTEMS C. EXCEPT IN HEAVY CLAY SOILS, MAKE RING OF 0 = OTHERWISE CLEAN PROJECT, STREETS,AND ( ) IRRIGATION WINTER SHUT-DOWN, BEGIN v SUBSTANTIAL COMPLETION. SPRINKLER INSTALLATIONS SIMILAR IN SIZE, SCOPE, 6. GIVE PIPE OR FITTING QUARTER TURN TO INSURE IN MOIST CONDITION. DO NOT ALLOW PLANT MOUNDED SOIL AROUND HOLE PERIMETER TO FORM c W HIGHWAYS. MAINTENANCE PERIOD AFTER START OF GROWING � _ Vf 2. INSTALLATIONS COMPLETED AFTER WATER SOURCE AND COMPLEXITY. EVEN DISTRIBUTION OF SOLVENT AND MAKE SURE SEASON AS AGREED WITH ARCHITECT,AND FOLIAGE TO DRY OUT. WATERING BASIN. cn B. DUST CONTROL: HAS BEEN TURNED OFF FOR SEASON,AS DETERMINED PIPE IS INSERTED TO FULL DEPTH OF FITTING SOCKET. CONTINUE ONE (1)CONTINUOUS MONTH 5. ADD FERTILIZER IN PLANT PIT AS PER `TOPSOIL TESTING � �> 1. TAKE PRECAUTIONS NECESSARY TO PREVENT DUST 8. PLANT MATERIAL: REPORT'AND DURING PROPER SEASON. BY LANDSCAPE ARCHITECT,WILL BE INSPECTED 8. WARRANTY: 7. ALLOW JOINTS TO SET AT LEAST TWENTY-FOUR(24) THEREFROM. 0 V NUISANCE, BOTH ON-SITE AND ADJACENT TO FOLLOWING SPRING AFTER SYSTEM CAN BE CHECKED WARRANTY IRRIGATION SYSTEM FOR PERIOD OF ONE 1 HOURS BEFORE APPLYING PRESSURE TO PVC PIPE. A. CONFORM TO REQUIREMENTS OF PLANT LIST AND KEY 6. FILL LANDSCAPE EXCAVATIONS WITH TAMPED PLANTING PUBLIC AND PRIVATE PROPERTIES. ( ) 3. REPLACE LANDSCAPING THAT IS DEAD OR APPEARS ON CONTRACT DOCUMENTS AND TO ANLA/ANSI Z60.1. MIX AND RECOMMENDED FERTILIZER: FOR PROPER OPERATION. YEAR FROM DATE OF SUBSTANTIAL COMPLETION. AS PART G. TAPE THREADED CONNECTIONS WITH TEFLON TAPE. UNHEALTHY OR NON-VIGOROUS AS DIRECTED BY 10 2. CORRECT OR REPAIR DAMAGE CAUSED BY DUST. B. PLANT NAMES USED IN PLANT LIST CONFORM TO A. COMPACT IN 6 INCH (150 MM)LIFTS. ao C. IRRIGATION APPROVAL: OF WARRANTY, INSTALLER SHALL PERFORM FOLLOWING: H. IF PIPE IS LARGER THAN 3 INCHES (75 MM), INSTALL JOINT ARCHITECT BEFORE END OF MAINTENANCE PERIOD.C. EXISTING PLANTS AND FEATURES: 1. IRRIGATION WILL BE APPROVED WHEN ALL 1) FILLING AND REPAIRING DEPRESSIONS AND RESTRAINTS WHEREVER CHANGE OF DIRECTION OCCURS MAKE REPLACEMENTS WITHIN TEN (10) DAYS OF 'STANDARDIZED PLANT NAMES'BY AMERICAN JOINT B. SETTLE BY WATERING TO ENSURE TOP OF ROOT 1. DO NOT DAMAGE TOPS,TRUNKS,AND ROOTS OF NON-CONFORMING WORK IS BROUGHT INTO REPLACING PLANTINGS DUE TO SETTLEMENT OF ON PVC MAIN LINES. NOTIFICATION. LAWN BEING REPLACED SHALL BE COMMITTEE ON HORTICULTURAL NOMENCLATURE BALL IS 2 INCHES (50 MM) HIGHER FOR TREES AND EXISTING TREES AND SHRUBS ON SITE THAT ARE CONFORMANCE. IRRIGATION SYSTEM TRENCHES. GUARANTEED AND MAINTAINED AN ADDITIONAL EXCEPT IN CASES NOT COVERED. IN THESE ONE INCH (25 MM) HIGHER FOR SHRUBS THAN INTENDED TO REMAIN. INSTANCES, FOLLOW CUSTOM OF NURSERY TRADE. SURROUNDING SOIL FOLLOWING COMPACTION AND 2. CORRECT ANY WORK FOUND DEFECTIVE OR NOT 2) REPAIRING FAULTY EQUIPMENT, WIRING AND PIPE 16.CONTROL VALVES AND CONTROL VALVE WIRING: THIRTY(30) DAYS FROM DATE OF REPLACEMENT.2. DO NOT USE HEAVY EQUIPMENT WITHIN BRANCH COMPLYING WITH CONTRACT DOCUMENT INSTALLATIONS. A. INSTALL VALVES IN PLASTIC BOXES WITH REINFORCED B. SEEDED LAWN: PLANTS SHALL BEAR TAG SHOWING GENUS, SPECIES, SETTLING. SPREAD. REQUIREMENTS AT NO ADDITIONAL COST TO OWNER. 3) REPAIRING EQUIPMENTAND PIPE NOT PROPERLY HEAVY-DUTY PLASTIC COVERS. LOCATE VALVE BOXES 1. SEEDED LAWN AREAS WILL NOT BE ACCEPTED AS AND VARIETY OF AT LEAST 10 PERCENT OF EACH 7. DO NOT USE MUDDY SOIL FOR BACKFILLING. 3. INTERFERING BRANCHES MAY BE REMOVED ONLY WINTERIZED. WITHIN 12 INCHES (300 MM)TO 24 INCHES (600 MM)OF COMPLETE AND THIRTY(30) DAY MAINTENANCE SPECIES DELIVERED TO SITE. 8. MAKE ADJUSTMENTS IN POSITIONS OF PLANTS AS WITH PERMISSION OF ARCHITECT. 3. WINTERIZATION AND SPRING START-UP: SIDEWALKS AND SHRUB BED EDGES WITH TOPS AT FINISH C. QUALITY: DIRECTED BY LANDSCAPE ARCHITECT. 4. DO NOT DAMAGE OTHER PLANTS AND FEATURES PERIOD WILL NOT BEGIN UNTIL UNIFORM STAND OF 1. PLANTS SHALL BE SOUND, HEALTHY,VIGOROUS, 9. THOROUGHLY WATER TREES AND SHRUBS IMMEDIATELY DURING FIRST YEAR OF OPERATION, INSTALLER SHALL 9. VERIFICATION OF CONDITIONS: GRADE. DO NOT INSTALL MORE THAN ONE (1)VALVE IN GRASS AT LEAST 3 INCHES (75 MM)TALL HAS BEEN THAT ARE TO REMAIN. SHUT-DOWN IRRIGATION SYSTEM PRIOR TO FREEZING A. PERFORM SOURCE PRESSURE TEST AT STUB-OUT ON SINGLE BOX. OBTAINED. FREE FROM PLANT DISEASE, INSECT PESTS OR AFTER PLANTING. 5. PROTECT UTILITIES AND SITE ELEMENTS FROM MAIN WATER LINE PROVIDED FOR IRRIGATION SYSTEM, B. INSTALL EQUIPMENT FOR EASE OF REMOVAL. THEIR EGGS, NOXIOUS WEEDS,AND HAVE 10.AT BASE OF EACH TREE, LEAVE 36 INCH (900 MM) A DAMAGE. TEMPERATURES AND RE-START IRRIGATION SYSTEM AT 2. AFTER GRASS IS ESTABLISHED AND 3 INCHES ( MM) HEALTHY, NORMAL ROOT SYSTEMS. CONTAINER DIAMETER CIRCLE FREE OF ANY GRASS. OR AT NEAR-BY FIRE HYDRANT. C. PLACE 3 INCHES (75 MM)MINIMUM OF PEA GRAVEL BELOW TALL, MOW LAWN AREAS AT LEAST WEEKLY TO A 6. LIMIT USE OF HEAVY EQUIPMENT TO AREAS NO BEGINNING OF GROWING SEASON: B. NOTIFY ARCHITECT IF PRESSURES OVER 70 PSI480 KPA . STOCK SHALL BE WELL ESTABLISHED AND FREE CLOSER THAN 6 FEET(1.80 METER) FROM BUILDING ( ) BRICKS SUPPORTING VALVE BOXES TO DRAIN BOX SET HEIGHT OF 2 INCHES (50 DURING THIS PERIOD, OF EXCESSIVE ROOT-BOUND CONDITIONS. A. WINTER SHUT-DOWN IS INTENDED TO REMOVE ALL OR UNDER 55 PSI (379 KPA)ARE FOUND TO DETERMINE IF VALVE BOXES OVER VALVE SO ALL PARTS OF VALVE CAN PERFORM WORK NECESSARY Y TO MAINTAIN A FULL, DO NOT PRUNE PLANTS OR TOP TREES PRIOR TO OR OTHER PERMANENT STRUCTURES. POTENTIALLY DAMAGING WATER FROM IRRIGATION SOME RE-DESIGN OF SYSTEM IS NECESSARY BEFORE BE REACHED FOR SERVICE. SET COVER OF VALVE BOX EVEN STAND OF GRASS. 2• DELIVERY. SYSTEM. PERFORM FOLLOWING AS WELL AS ANY BEGINNING WORK ON SYSTEM. EVEN WITH FINISH GRADE. VALVE BOX CAVITY SHALL BE 3. AT END OF THIRTY(30) DAYS OF MAINTENANCE 3. PLANT MATERIALS SHALL BE SUBJECT TO 3. REPAIR/RESTORATION: OTHER EFFORTS NECESSARY TO PROPERLY REASONABLY FREE FROM DIRTAND DEBRIS. PERIOD, FERTILIZE LAWNS. A. ADJUST EXISTING COVERS, BOXES,AND VAULTS TO WINTERIZE SYSTEM: 10. PROTECTION: D. WIRING: 4. APPLY HERBICIDES AS NECESSARY IN ORDER TO APPROVAL BY LANDSCAPE ARCHITECT AS TO SIZE, GRADE. 1) TURN OFF WATER SOURCE AT POINT OF A. REPAIR OR REPLACE WORK DAMAGED DURING COURSE 1. USE WATERPROOF WIRE CONNECTORS CONSISTING OBTAIN WEED FREE LAWN. APPLY HERBICIDE IN HEALTH, QUALITY,AND CHARACTER. B. REPLACE BROKEN OR DAMAGED COVERS, BOXES,AND CONNECTION. OF WORK AT NO ADDITIONAL COST TO OWNER. IF OF PROPERLY-SIZED WIRE NUT AND GREASE CAP AT ACCORDANCE WITH MANUFACTURER'S 4. BARE ROOT TREES ARE NOT ACCEPTABLE. VAULTS. 2) BLOW OUT SYSTEM WITH PRESSURIZED AIR, DAMAGED WORK IS NEW, INSTALLER OF ORIGINAL WORK SPLICES AND LOCATE ALL SPLICES WITHIN VALVE INSTRUCTIONS DURING CALM WEATHER WHEN AIR 5. PROVIDE PLANT MATERIALS FROM LICENSED C. INDEPENDENTLY CONFIRM SIZE, LOCATION,AND TURNING ON EACH VALVE UNTIL WATER IS CLEARED SHALL PERFORM REPAIR OR REPLACEMENT. BOXES. TEMPERATURE IS BETWEEN 50 AND 80 DEG F (10 AND NURSERY OR GROWER. NUMBER OF COVERS, BOXES,AND VAULTS THAT B. DO NOT CUT EXISTING TREE ROOTS MEASURING OVER 2 a) WIRE LENGTH FROM ANY DECODER TO THE D. MEASUREMENTS: OUT OF SYSTEM. RUN THROUGH SYSTEM TWICE. 27 DEG C). REQUIRE ADJUSTMENT. ONLY BLOW OUT COMPONENTS SUITABLE TO INCHES (50 MM) IN DIAMETER IN ORDER TO INSTALL CONTROLLER SHALL BE NO MORE THAN 8,500 FT(2 C. SODDED LAWN: 1. MEASURE HEIGHTAND SPREAD OF SPECIMEN PLANT RECEIVE PRESSURIZED AIR. HYDROMETERS, FOR IRRIGATION LINES. 590 M). 1. MAINTAIN SODDED LAWN AREAS UNTIL LAWN MATERIALS WITH BRANCHES IN THEIR NORMAL 4. NON-CONFORMING WORK: b DO NOT LOOP WIRING. POSITION AS INDICATED ON CONTRACT DOCUMENTS INSTANCE, SHOULD NOT BE BLOWN OUT. DO NOT ) COMPLIES WITH SPECIFIED REQUIREMENTS AND A. IF SPECIFIED PROTECTION PRECAUTIONS ARE NOT 11. LAYOUT OF IRRIGATION SYSTEM: c) INSTALL LIGHTNING ARRESTOR(S)AS PER OR PLANT LIST. Q USE EXCESSIVE AIR PRESSURE THAT WILL DAMAGE THROUGHOUT MAINTENANCE PERIOD. TAKEN OR CORRECTIONS AND REPAIRS NOT MADE A. LOCATION OF IRRIGATION EQUIPMENT SHOWN ON MANUFACTURER'S RECOMMENDATIONS. 2. MEASUREMENT SHOULD BE AVERAGE OF PLANT, NOT PIPES AND PARTS. 2. WATER SODDED AREAS IN SUFFICIENT QUANTITIES PROMPTLY, OWNER MAY TAKE SUCH STEPS AS MAY BE CONTRACT DRAWINGS IS APPROXIMATE. ACTUAL d FOLLOW ALL OTHER MANUFACTURER GREATEST DIAMETER. FOR EXAMPLE, PLANT 3) TURN CONTROLLER OFF OR IF AVAILABLE TURN TO ) AND AT REQUIRED FREQUENCY TO MAINTAIN DEEMED NECESSARY AND DEDUCT COSTS OF SUCH PLACEMENT MAY VARY SLIGHTLY AS IS REQUIRED TO RECOMMENDATIONS WHEN INSTALLING WIRE. MEASURING 15 INCHES (375 MM) IN WIDEST PERTINENT WINTERIZATION. SUB-SOIL IMMEDIATELY UNDER SOD CONTINUOUSLY FROM MONIES DUE TO CONTRACTOR. SUCH ACTION OR ACHIEVE FULL, EVEN COVERAGE WITHOUT SPRAYING 2. TRADITIONAL WIRING: DIRECTION AND 9 INCHES (225 MM) IN NARROWEST O 4) OPEN ALL MANUAL DRAIN VALVES. MOIST 3 TO 4 INCHES (75 TO 100 MM)DEEP. LACK OF ACTION ON OWNER'S PART DOES NOT RELIEVE ONTO BUILDINGS, SIDEWALKS, FENCES, ETC. a) TAPE CONTROL WIRE TO SIDE OF MAIN LINE EVERY WOULD BE CLASSIFIED AS 12 INCH (300 MM)STOCK. Q 5) DRAIN,WRAP, PROTECT, OR REMOVE ANY 3. CUT GRASS FIRST TIME WHEN IT REACHES 3 INCHES CONTRACTOR FROM RESPONSIBILITY FOR PROPER B. DURING LAYOUT, CONSULT WITH ARCHITECT TO VERIFY 10 FEET(3.050 M WHERE CONTROL WIRE LEAVES 3. PLANTS PROPERLY TRIMMED AND TRANSPLANTED BACKFLOW DEVICE EXPOSED TO FREEZING ( � )� (75 MM) HIGH. CONTINUE TO MOW AT LEAST ONCE PROTECTION OF THE WORK. PROPER PLACEMENTAND MAKE RECOMMENDATIONS, MAIN OR LATERAL LINE, ENCLOSE IT IN GRAY SHOULD MEASURE SAME IN EVERY DIRECTION. TEMPERATURES USING MANUFACTURER'S EACH WEEK THROUGHOUT MAINTENANCE PERIOD. MEASURE CALIPER OF TREES 6 INCHES (150 MM) RECOMMENDATIONS AND BEST PRACTICES. WHERE REVISIONS ARE ADVISABLE. CONDUIT. REMOVE CLIPPINGS. 4. ABOVE SURFACE OF GROUND. COORDINATE METHOD WITH OWNER'S C. MINOR ADJUSTMENTS IN SYSTEM LAYOUT WILL BE b) USE WHITE OR GRAY COLOR FOR COMMON WIRE 4. APPLY HERBICIDE AS NECESSARY TO MAINTAIN 5. WHERE CALIPER OR OTHER DIMENSIONS OF PLANT REPRESENTATIVE. PERMITTED TO AVOID EXISTING FIXED OBSTRUCTIONS. AND OTHER COLORS FOR ALL OTHER WIRE. EACH WEED-FREE LAWN. APPLY HERBICIDE IN 6) DRAIN AND REMOVE PUMPS FOR OWNER'S D. MAKE CERTAIN CHANGES FROM CONTRACT DOCUMENTS COMMON WIRE MAY SERVE ONLY ONE (1) ACCORDANCE WITH MANUFACTURER'S MATERIALS ARE OMITTED FROM PLANT LIST, PLANT Q REPRESENTATIVE STORAGE. ARE SHOWN ON RECORD DRAWINGS. CONTROLLER. INSTRUCTIONS DURING CALM WEATHER WHEN AIR MATERIALS SHALL BE NORMAL STOCK FOR TYPE - c) RUN ONE (1)SPARE CONTROL WIRE FROM PANEL TEMPERATURE IS BETWEEN 50 AND 80 DEG F 10 AND LISTED. O 7) DRAIN FILTERS USING MANUFACTURER'S ( 6. PLANT MATERIALS LARGER THAN THOSE SPECIFIED .. RECOMMENDATIONS. 12.TRENCHING AND BACKFILLING: CONTINUOUSLY FROM VALVE TO VALVE 27 DEG C). 8) CHECK SPRINKLER HEADS TO MAKE SURE THEY WITH PRIOR WRITTEN APPROVAL z �A. PULLING OF PIPE IS NOT PERMITTED. THROUGHOUT SYSTEM SIMILAR TO COMMON WIRE 5. AT END OF THIRTY(30) DAY MAINTENANCE PERIOD, MAY BE SUPPLIED, Z TOPSOIL & GRADING NOTES OF LANDSCAPE ARCHITECT,AND:B. EXCAVATE TRENCHES TO SPECIFIED DEPTH. REMOVE FOR USE AS REPLACEMENT IF WIRE FAILS: FERTILIZE LAWNS.ARE BELOW SIDEWALK AND CURB LEVELS AND NOT � ) 1 VULNERABLE TO SNOWPLOW DAMAGE. LOWER ROCKS LARGER THAN 1-1/2 INCH (38 MM) IN ANY 1) RUN SPARE WIRE TO EACH BRANCH OF SYSTEM. D. TREES, SHRUBS,AND PLANTS: REQUIREMENTS IN ALL OTHER RESPECTS.a) IF COMPLYING WITH CONTRACT DOCUMENT �J v 1. IMPORTAND INSTALL TOPSOIL AS NEEDED TO FILL ALL HEADS TO PROPER ELEVATION. DIRECTION FROM BOTTOM OF TRENCH. SEPARATE OUT 2) SPARE WIRE SHALL BE DIFFERENT COLOR THAN 1. MAINTAIN BY PRUNING, CULTIVATING,AND WEEDING Q PLANTING AREAS. SUBMIT TEST BY LICENSED LABORATORY 9) NOTIFY OWNER'S REPRESENTATIVE WHEN SYSTEM ROCKS LARGER THAN 1-1/2 INCH (38 MM) IN ANY OTHER WIRES. USE OF GREEN WIRE IS NOT AS REQUIRED FOR HEALTHY GROWTH. b) IF AT NO ADDITIONAL COST TO OWNER. TO LANDSCAPE ARCHITECT FOR APPROVAL PRIOR TO DIRECTION UNCOVERED IN TRENCHING OPERATION FROM ACCEPTABLE. c) IF SIZES OF ROOTS OR BALLS ARE INCREASED INSTALLATION.TOPSOIL USED IN LANDSCAPED AREAS SHALL HAS BEEN TURNED OFF. 2. RESTORE PLANTING BASINS. PROPORTIONATELY. B. SPRING START-UP SHALL INCLUDE FOLLOWING: EXCAVATED MATERIAL AND REMOVE FROM AREAS TO 3) MARK SPARE CONTROL WIRE VISIBLY WITHIN 3. TIGHTEN AND REPAIR STAKE AND GUY SUPPORTS BE WEED FREE, FERTILE, LOOSE, FRIABLE SOIL MEETING THE RECEIVE LANDSCAPING. VALVE BOX AS AN 'UN-CONNECTED WIRE'. E. SHAPE AND FORM: 1) CLOSE ALL MANUAL VALVES. AND RESET TREES AND SHRUBS TO PROPER GRADES FOLLOWING CRITERIA: C. COVER PIPE BOTH TOP AND SIDES WITH 2 INCHES 50 MM EXTEND SPARE CONTROL WIRES 24 INCHES 600 1. PLANT MATERIALS SHALL BE SYMMETRICAL OR W 2) CLEAN PUMP FILTERS AND REPLACE IF NECESSARY. ( ) ( OR VERTICAL POSITIONS AS REQUIRED. � �^ 3) REMOVE FREEZE PROTECTION AS REQUIRED. OF ROCK-FREE SOIL OR SAND. REMAINDER OF BACKFILL MM)AND LEAVE COILED IN EACH VALVE BOX. 4. SPRAY AS REQUIRED TO KEEP TREES AND SHRUBS TYPICAL FOR VARIETY AND SPECIES AND CONFORM `/J 1) CHEMICAL CHARACTERISTICS: TO TOPSOIL DEPTH USING NATIVE MATERIAL. MARK SPARE WIRE VISIBLY WITHIN CONTROLLER TO MEASUREMENTS SPECIFIED IN PLANT LIST. a) SOLUBLE SALTS: LESS THAN 3.0 MMHOS/CM. 4) TURN ON WATER SOURCE AT POINT OF CONNECTION. FREE OF INSECTS AND DISEASE.R 2. WELL GROWN MATERIAL WILL GENERALLY HAVE M 5) VERIFY THAT CONTROLLER(S)AND RAIN SENSOR ARE D. DO NOT COVER PRESSURE MAIN, IRRIGATION PIPE, OR AS `UN-CONNECTED WIRE'. 5. PROVIDE SUPPLEMENTAL WATER BY HAND AS W b) PH 5.5 TO 8.0. FITTINGS UNTIL LANDSCAPE ARCHITECT HAS INSPECTED E. ARRANGE VALVE STATIONS TO OPERATE IN AN HEIGHT EQUAL TO OR GREATER THAN SPREAD. PROPERLY OPERATING. CHANGE BATTERY IN NEEDED IN ADDITION TO WATER FROM SPRINKLING c) SODIUM ABSORPTION RATIO (SAR): LESS THAN 6.0. AND APPROVED SYSTEM. EASY-TO-VIEW PROGRESSIVE SEQUENCE AROUND HOWEVER, SPREAD SHALL NOT BE LESS THAN 2/3'S LIJ CONTROLLER(S)AND SENSOR(S)AS REQUIRED. SYSTEM. d) ORGANIC MATTER: GREATER THAN ONE PERCENT. 6) FLUSH ENTIRE SYSTEM. RUN EACH VALVE FOR TWO (2) BUILDING. TAG VALVES WITH WATERPROOF LABELS OF HEIGHT. 2) PHYSICAL CHARACTERISTICS: MINUTES TO CHECK FOR DAMAGE, LEAKS,AND 13. SLEEVING: SHOWING FINAL SEQUENCE STATION ASSIGNMENTS. 5. PROTECTION: O a) GRADATION AS DEFINED BY USDA TRIANGLE OF A. SLEEVE WATER LINES AND CONTROL WIRES UNDER 9. EXCAVATION: COVERAGE. A. PROTECT PLANTED AREAS AGAINST TRAFFIC OR OTHER PHYSICAL CHARACTERISTICS AS MEASURED BY WALKS AND PAVING. EXTEND SLEEVES 6 INCHES (150 MM) 17.SPRINKLER HEADS AND ROTOR POP-UPS: A.IF UNDERGROUND CONSTRUCTION WORK OR u , 7) REPAIR AND ADJUST SYSTEM AS NEEDED. FINE TUNE USE IMMEDIATELY AFTER PLANTING IS COMPLETED BY � HYDROMETER. HEADS FOR EFFICIENT COVERAGE. MINIMUM BEYOND WALK OR PAVEMENT EDGE. COVER A. SET SPRINKLER HEADS AND QUICK-COUPLING VALVES PLACING ADEQUATE WARNING SIGNS AND BARRICADES. OBSTRUCTIONS ARE ENCOUNTERED IN EXCAVATION OF (1)SAND: 15 TO 60 PERCENT. 8) NOTIFY OWNER'S REPRESENTATIVE WHEN SYSTEM SLEEVE ENDS UNTIL PIPES AND WIRES ARE INSTALLED TO PERPENDICULAR TO FINISH GRADE. B. PROVIDE ADEQUATE PROTECTION OF PLANTED AREAS ^ ' PLANTING HOLES, LANDSCAPE ARCHITECT WILL SELECT ` V (2)SILT: 10 TO 60 PERCENT. KEEP SLEEVE CLEAN AND FREE OF DIRT AND DEBRIS. B. DO NOT INSTALL SPRINKLERS USING SIDE INLETS. ALTERNATE LOCATIONS. /� M 3 CLAY: 5 TO 30 PERCENT. HAS BEEN CHARGED AND IS IN FULL REPAIR. AGAINST TRESPASSING, EROSION,AND DAMAGE OF ANY B.PLANT EXCAVATION SIZE: v J ` ' ( ) B. POSITION SLEEVES WITH RESPECT TO BUILDINGS AND INSTALL USING BASE INLETS ONLY. KIND. REMOVE THIS PROTECTION AFTER ARCHITECT 1. DIAMETER: TWICE DIAMETER OF ROOT BALL OR b) CLEAN AND FREE FROM TOXIC MINERALS AND 4. SUBMIT MANUFACTURER'S CUT SHEETS FOR EACH ELEMENT OTHER OBSTRUCTIONS SO PIPE CAN BE EASILY C. HEADS IMMEDIATELY ADJACENT TO MOW STRIPS, WALKS, HAS ACCEPTED PLANTED AREAS. CHEMICALS, NOXIOUS WEEDS, ROCKS LARGER THAN REMOVED. OR CURBS SHALL BE CONTAINER MINIMUM. OR EQUAL TO 1-1/2 INCH 38 MM IN ANY DIMENSION, OF SYSTEM TO THE LANDSCAPE ARCHITECT OR DESIGNATED C. TAKE CARE IN PERFORMING LANDSCAPING WORK TO 2. DEPTH: EQUAL TO CONTAINER OR ROOTBALL DEPTH. ( ) REPRESENTATIVE(S) FOR REVIEW AND APPROVAL PRIOR TO C. INSTALL SLEEVES AND CONDUIT BEFORE INSTALLATION AVOID CONDITIONS THAT WILL CREATE HAZARDS. POST AND OTHER OBJECTIONABLE MATERIALS. BEGINNING INSTALLATION. OF CAST-IN-PLACE CONCRETE SITE ELEMENTS AND SIGNS OR BARRIERS AS REQUIRED. C.UNLESS EXCAVATED MATERIAL MEETS TOPSOIL c)SOIL: PAVING. COORDINATE WITH APPROPRIATE REQUIREMENTS AS SPECIFIED IN "TOPSOIL& GRADING (1)SOIL SHALL NOT CONTAIN MORE THAN FIVE (5) D. PROVIDE ADEQUATE MEANS FOR PROTECTION FROM NOTES", REMOVE FROM LANDSCAPE AREAS AND DO NOT 5. CLOSEOUT SUBMITTALS: SUB-CONTRACTOR AS NEEDED FOR TIMELY DAMAGE THROUGH EXCESSIVE EROSION, FLOODING, PERCENT BY VOLUME OF ROCKS MEASURING A. SUBMITTAL FORMAT: DIGITAL FORMAT ONLY. INSTALLATION. HEAVY RAINS, ETC. REPAIR OR REPLACE DAMAGED USE FOR LANDSCAPING PURPOSES. OVER 1/4 INCH (6 MM) IN LARGEST SIZE. B. OPERATIONS AND MAINTENANCE DATA: AREAS. D.ROUGHEN SIDES AND BOTTOMS OF EXCAVATIONS. (2)SOIL SHALL BE TOPSOIL IN NATURE. 1) PROVIDE IRRIGATION SYSTEM OPERATION AND 14. GRADES AND DRAINING: E. KEEP SITE WELL DRAINED AND LANDSCAPE E.WITH APPROVAL OF LANDSCAPE ARCHITECT, SELECT FIVE (3)SOIL RESEMBLING ROAD BASE OR OTHER LIKE MAINTENANCE RECOMMENDATIONS. IN LOCALITIES WHERE WINTERIZATION IS REQUIRED, EXCAVATIONS DRY. (5)TYPICAL PLANTING EXCAVATIONS THROUGHOUT SITE MATERIALS ARE NOT ACCEPTABLE. GRADE PIPING SO SYSTEM CAN BE COMPLETELY FOR DRAINAGE TESTING. 2) PROVIDE IRRIGATION SYSTEM OPERATION AND AT WATER DRAINS AWAYAT RATE OF 3 INCHES (75 THAT MAINTENANCE RECOMMENDATIONS FROM DRAINED OR BLOWN OUT WITH COMPRESSED AIR. IF 6. WARRANTY: 1. TH PER HOUR MINIMUM. INFORM LANDSCAPE 2. INSTALLA MINIMUM DEPTH OF 5 INCHES TOPSOIL IN LAWN SYSTEM IS NOT DESIGNED TO BE BLOWN OUT WITH ) AND GROUND COVER PLANTING AREAS. NO TOPSOIL MANUFACTURERS. 1. PROVIDE WRITTEN WARRANTIES AS FOLLOWS: ARCHITECT IN WRITING OF EXCAVATIONS WHERE 3) PROVIDE IRRIGATION SYSTEM WINTERIZATION COMPRESSED AIR: A. WARRANTY WILL EXTEND THIRTY(30)CONTINUOUS REQUIRED IN TREE AND SHRUB PLANTING AREAS OR INSTRUCTIONS. 1. SLOPE PIPE TO DRAIN TO CONTROL VALVE BOX WHERE DAYS MINIMUM AFTER SUBSTANTIAL COMPLETION. IF WATER DOES NOT DRAIN PROPERLY. NATIVE GRASS, SHRUB, OR TREE AREAS AS LONG AS WHAT IS POSSIBLE. 2. SELECT THREE (3) EXCAVATIONS APPROXIMATELY 5 Z 4) PROVIDE PLANT ESTABLISHMENT PERIOD WATERING A CONTINUOUS FIRST THIRTY(30) DAYS OF THE O IN PLACE IS NOT EXCESSIVELY ROCKY OR OTHERWISE SCHEDULE. 2. WHERE THIS IS NOT POSSIBLE, SLOPE PIPE TO FEET(1 500 MM)AWAY FROM EACH NON-DRAINING WARRANTY PERIOD IS INTERRUPTED BY EXCAVATION AND REPEAT TESTS. CONTINUE TESTING UNFAVORABLE TO HEALTHY PLANT GROWTH. IF IT IS 5) PROVIDE POST PLANT ESTABLISHMENT PERIOD MINIMUM NUMBER OF LOW POINTS. AT THESE LOW NON-GROWING SEASON OR IRRIGATION WINTER 0- UNFAVORABLE, INSTALLA MINIMUM DEPTH OF 12 INCHES. POINTS, INSTALL: PROCESS UNTIL NON-DRAINING AREAS HAVE BEEN Z WATERING SCHEDULE. SHUT-DOWN, BEGIN WARRANTY PERIOD AFTER O U PROVIDE NO LESS THAN QUANTITY REQUIRED TO ACHIEVE a) 3/4 INCH (19 MM) BRASS BALL VALVE FOR MANUAL IDENTIFIED. C. IRRIGATION SYSTEM WARRANTY DOCUMENTATION. START OF GROWING SEASON AS AGREED ON WITH TOLERANCES OUTLINED IN PLANTING NOTE 5. INSTALLER OF DRAIN. DO NOT USE AUTOMATIC DRAIN VALVES. 3. IN EXCAVATIONS LOCATED IN IDENTIFIED NON-DRAINING U) D. RECORD DOCUMENTATION: ARCHITECT.THEREAFTER, CONTINUE WARRANTY THIS SECTION IS RESPONSIBLE FOR PROVIDING SUFFICIENT b) INSTALL 2 INCH 50 MM AREAS,AUGER 6 INCH (150 MM) DIAMETER HOLE 4 FEET (I) w TOPSOIL MATERIAL. 1) PROVIDE MANUFACTURER'S PRINTED LITERATURE AND ( )CLASS 200 PVC PIPE OVER PER THE PERIOD DESCRIBED HEREIN. (1 200 MM) DEEP IN LOW POINT OF EACH EXCAVATION \ CUT SHEETS FOR EACH ELEMENT OF SYSTEM. TOP OF DRAIN AND CUTAT FINISH GRADE. B. WARRANTY SHRUBS, GROUND COVERS,AND VINES AND FILL WITH TAMPED PLANTING MIX. 2) TESTING AND INSPECTION REPORTS c) PROVIDE RUBBER VALVE CAP MARKER. TO LIVE AND REMAIN IN STRONG,VIGOROUS,AND 4. DO NOT PLANT TREES OR SHRUBS IN HOLES THAT DO W 3. FINISH TOPSOIL GRADE PLANTING AREAS BEFORE 3) IRRIGATION RECORD DRAWINGS. AS INSTALLATION d) PROVIDE ONE CU FT(0.03 CU M) PEA GRAVEL SUMP HEALTHY CONDITION FOR 90 DAYS MINIMUM FROM PLANTING AND AFTER ADDITION OF SOIL ADDITIVES SHALL OCCURS, PREPARE ACCURATE RECORD DRAWING TO AT OUTLET OF EACH DRAIN. DATE OF SUBSTANTIAL COMPLETION. NOT PROPERLY DRAIN. BE SPECIFIED DISTANCES BELOW TOP OF ADJACENT BE SUBMITTED BEFORE FINAL INSPECTION, 3. SLOPE PIPES UNDER PARKING AREAS OR DRIVEWAYS C. WARRANTY TREES TO LIVE AND REMAIN IN Lu PAVEMENT OF ANY KIND: INCLUDING: TO DRAIN OUTSIDE THESE AREAS. STRONG,VIGOROUS,AND HEALTHY CONDITION FOR H a) GROUND COVER AREAS: 2 INCHES BELOW. A) DETAILAND DIMENSION CHANGES MADE DURING 4. PROVIDE AND INSTALL QUICK-COUPLING VALVE OR ONE YEAR FROM DATE OF SUBSTANTIAL Q b) SEEDED AREAS: ONE INCH BELOW. CONSTRUCTION. RECORD AT TIME OF VALVES IN LOCATION FOR EASY BLOWOUT OF ENTIRE COMPLETION. c) SODDED AREAS: 2 INCHES BELOW. INSTALLATION. SYSTEM. INSTALL QUICK COUPLER VALVES WITH 2 D. WHEN TREES ARE COMPLETELY ACCEPTED AT END a a a a a a a d) TREE AND SHRUB AREAS (NOT INDIVIDUAL TREES): 4 B) SIGNIFICANT DETAILS AND DIMENSIONS NOT LINEAL FEET(0.60 M) MINIMUM OF GALVANIZED PIPE OF WARRANTY PERIOD, REMOVE STAKING. INCHES BELOW. SHOWN IN ORIGINAL CONTRACT DOCUMENTS. BETWEEN VALVE AND MAIN LINE. 4. RAKE THE FINISH GRADE OF THE TOPSOIL WITHIN THE C) FIELD DIMENSIONED LOCATIONS OF VALVE BOXES, PROJECT NO: 21070 PLANTING AREAS TO REMOVE CLODS, ROCKS, WEEDS, MANUAL DRAINS, QUICK-COUPLER VALVES, DRAWN BY: TG ROOTS, DEBRIS OR OTHER MATERIAL 1-1/2" OR MORE IN ANY CONTROL WIRE RUNS NOT IN MAINLINE DITCH AND DRAWING INDEX DIMENSION. GRADE AND SHAPE LANDSCAPE AREA TO BRING BOTH ENDS OF SLEEVES. CHECKED BY: SS SURFACE TO TRUE UNIFORM PLANES FREE FROM D) TAKE DIMENSIONS FROM PERMANENTSHEET DESCRIPTION CONSTRUCTED SURFACES OR EDGES LOCATED AT IRREGULARITIES AND TO PROVIDE PROPER SLOPE FOR CO STRUBOVE FINISH GRADE. DATE: SEPTEMBER 2021 DRAINAGE. E) TAKE AND RECORD DIMENSIONS AT TIME OF L0.01 LANDSCAPE NOTES &SPECIFICATIONS PROPERTY NO: INSTALLATION. 4) PROVIDE PHOTOGRAPHS PRIOR TO BURIAL OF KEY L2.01 LANDSCAPE PLANTING PLAN ELEMENTS. L3.01 LANDSCAPE IRRIGATION PLAN LANDSCAPE E. FINAL PAYMENT FOR SYSTEM WILL NOT BE AUTHORIZED NOTES & UNTIL CLOSEOUT SUBMITTALS ARE RECEIVED AND L5.01 LANDSCAPE DETAILS SPECIFICATIONS ACCEPTED BY ARCHITECT AND LANDSCAPE ARCHITECT.. L5.02 LANDSCAPE DETAILS L5.03 LANDSCAPE DETAILS L0m0l F E I ALTA H ILLS LANE (' ° , LANDSCAPE SCHEDULE it u! u! u! :...... m! bW L N Z SYMBOL QTY. COMMON NAME BOTANICAL NAME SIZE DETAIL - .................................................................................................................................................................................................................................................................. _ 4 DECIDUOUS TREES \ 3 u S \ ............................................ ........................................... ............................................ 0° c E € 4 to :::::::::::::::::::::::::::::::::::::::::r' CD W � was • ............................................ - ■ 12 ROCKY MOUNTAIN GLOW MAPLE ACER GRANDIDENTATUM'SCHMIDT' 2"CAL. D/L5.01 ed CA O .. ............................................ ........................................... ............................................ I -- -- � • ... CL ............................................................................................... ca 00 ed Sao twJ ... ............................................ ........................................... ....... • FUTURE F o � •• 1 ACE OF HEARTS REDBUD CERCIS CANADENSIS'ACE OF HEARTS' 8'-10'CLUMP D/L5.01 r; ❑j/�� _ i BUILDING ; W T c ................................................ € - 4,550 S.F. I ....................................... o _ L i � _ V c (14 ............................................ ........................................... ............................................ •c --- SEE INGELWOOD SUBDIVISION NO. 2 = W LLI LANDSCAPE PLAN SET FOR STRET ............................................... ` •L r FRONTAGE AND OVERALL OPEN ............................................ ........................................... ............................................ E.... L SPACE PLANS z o : Vs cd .... 1 • 6 ALLEE LACEBARK ELM ULMUS PARVIFLORA'ELMER II' 2"CAL. D/L5.01 -- ................................................ ; T =................................................ i Z II W N s „............................................... ................................................Q ` •> ........................................... .... W CD............................................ J J � u �� 00 EVERGREEN TREES �I ....................................... CEDRUSALANTICA'HORSTMANN' ----------------------- ---- ---------___-----_-----__-----_-----___--19 HORSTMANN BLUE ATLAS CEDAR a ; p ORNAMENTAL GRASSES I J .•-•.-•.••-•.-•.••-•.-•.••-•.-•.••-•.-•.•-• ' 0 ' 45r 202 BLONDE AMBITION BLUE GRAMA GRASS BOUTELOUA GRACILIS'BLONDE AMBITION' 5 GAL. A/L5.01 '- i I.L ............................................ I I I + 182 FOERSTER'S FEATHER REED GRASS CALAMAGROSTIS XACUTIFLORA'KARL FOERSTER' 5 GAL. A/L5.01M*o*Q a; ............................................ I `'••. •-. '?dam?dam-%,di'„�..°,;<c � I 63 SAPPHIRE BLUE OAT GRASS HELICTOTRICHON SEMPERVIRENS'SAPHIRSPRUDEL' 5 GAL. A/L5.01 I SHRUBS .. I ............................................ � 3 BLUE JEAN BABY RUSSIAN SAGE PEROVSKIAATRIPLICIFOLIA'BLUE JEAN BABY' 5 GAL. B/L5.01 ............................................ I I II I � I • � I i is 55 DWARF JAPANESE GARDEN JUNIPER JUNIPERUS PROCUM BENS'NANA' 5 GAL. B/L5.01 I ETEN ON I : BAS I n ❑ PROPOSED Q�.a i ,`�•.,` ...............:4�...................... I � _ BUILDING ` O 35 GRO-LOW FRAGRANT SUMAC RHUSAROMATICA'GRO-LOW' 5 GAL. B/1-5.01 Q I FFE = 2691.00' , 0 2,365 SQ.FT. ,' -..,, i � ........................................... ❑ �. E �Q- S 16 JAKOBSEN MUGO PINE PINUS MUGO'JAKOBSEN' 5 GAL. B/L5.01 WJ /� I =Qv L Q V _ i V Q O - 4 I 7 • } 5 NEW MEXICO PRIVET FORESTIERA NEOMEXICANA 5 GAL. B/L5.01 W • i Z U) U - SYMBOL QTY. DESCRIPTION SOURCE SIZE INSTRUCTIONS DETAIL LAWN TYP. U W 286 S.F. LAWN INSTALL OVER MINIMUM 5" F/L5.01 �+ TOPSOIL LAYER ,: ! REQUIRED OPEN SPAC ROCK, MULCH &BOULDERS ? ;; - - LLI =5%Y = ` 1,789 S.F. : :.. ................ 0 INSTALLED A MINIMUM 3" �l , i RETENTION � �" ` -• ••��--�-��-•� ........... - .. ......... .... DEEP. INSTALL OVER DEWITTS _RETENTIO IDAHO MATERIALS&CONSTRUCTION (208)853-8600 3/4" 4.1 WEED BARRIER FABRIC. i ; BASIN �� .......:...................................................... ........... 22,029 S.F. CHIP ROCK G/L5.01 � .................. ......... _ .............................. OR APPROVED EQUAL DIAMETER CRUSHED ROCK SHALL BE " "� "` """""""'sl„ .................................................. FREE OF DIRT&OTHER z ...................................... :' .......... ............................................................ M FOREIGN DEBRIS. C♦ -------------- BURY 1/3 THE DEPTH OF THE BOULDER INTO FINISH --------- - GRADE. DO NOT USE IDAHO MATERIALS&CONSTRUCTION (208)853-8600 BOULDERS THATARE LESS 28 WINDRIFT" BOULDERS 2'-4' H/L5.01 "°` ------- AL 4 DI OR APPROVED EQUAL THAN 2 DIAMETER. --•--- _____________:::__:_:_:_ - - - - __ ---- : ____ BOULDER SHALL BE WASHED - AND FREE OF DIRT AND OTHER FOREIGN DEBRIS o VICTORY ROAD 0 0 SITE AMENITY SCHEDULE z 0 SYMBOL QTY. MANURFACTURER DESCRIPTION SIZE COLOR REFERENCE NOTES MERIDIAN CITY DATA z a 1. CAST-IN-PLACE CONCRETE SEAT WALL, 18"W.X 18" H. CITY CODE-TITLE 11 CH. 2&3 p U DETAIL I/L5.01 ZONED AS C-C(COMMUNITY BUSINESS DISTRICT) 0 20 40 60 FT — cn 35 COLLECTION- MINGLE (R), (n W 3 LANDSCAPE FORMS, INC. OUTDOOR TABLE W/4 82" DIAM.X 29" HT. SILVER 2. 12' DIAMETER TREE CUTOUT TOTAL SITE AREA 36,146 S.F. BACKLESS SEATS 3. 4' DIAM.TREE CUTOUT PERCENTAGE OF SITE IN LANDSCAPE AREA 14,778 S.F. =41% W 4. PRE-CAST PAVERS REQUIRED PROVIDED CENTRAL PARK GENERAL: W Q 2 LANDSCAPE FORMS, INC. CONSERVANCY, WASTE RECEPTACLE, 8.5" DIAMETER 30 GAL., 25"W X 35" H 1 GREY, 1 GREEN 40% TOP-OPENING" PLANT COVERAGE (MIN. FOR WATER 50% GENERAL NOTE CONSERVING DESIGN) W a a a a a a a OPEN SPACE 5%OF TOTAL AREA 1,698 S.F. =5% 1. REFER TO COMMON EARTHWORK AND PLANTING NOTES ON STREET BUFFER: PROJECT NO: 21070 SHEET LO.01 1 CAST-IN-PLACE CURVED 18"W X 18" H X 30' L REQUIRED TREES- 1 TREE PER 35 L.F. DRAWN BY: TG CONCRETE SEATWALL EAGLE ROAD (EXCL. EASEMENT) 158'/35=5 5 CHECKED BY: SS AVOID CUTTING UNDERGROUND VICTORY ROAD 228'/35=7 7 UTILITIES. ITS COSTLY. NOTICE! NORTH DATE: SEPTEMBER 2021 PERIMETER PARKING LOT/DRIVE LANDSCAPE: Call PROPERTY NO: THE CONTRACTOR SHALL BE 5'WIDE LANDSCAPE BUFFER ADJACENT TO PARKING YES RESPONSIBLE FOR THE LOCATION, 0 2 CAST-IN-PLACE CONCRETE 18"W X 18" H X 10' L BEFORE YOU PROTECTION,AND RESTORATION LANDSCAPE SEATWALL REQUIRED TREES- 1 PER 35 L.F. 264'/35=8 8 OF ALL BURIED OR ABOVE PLANTING Dig INTERIOR PARKING LOT LANDSCAPE: GROUND UTILITIES,SHOWN OR NOT SHOWN ON THE PLANS. 1> PLAN LANDSCAPE PLANTERS (50 S.F. MIN.)- 1 PER 12 STALLS 19 STALLS/ 12 =2 2 1-800-662-4111 REQUIRED TREES- 1 PER PLANTER 2 X 1 TREE=2 3 L2m01 F E I ALTA HILLS LANE (' i' N L N Y d Y YYYi YYY! �W! b'W L N E 4J IRRIGATION SCHEDULE bO4J. . .................................................................................................................................................................................................................................................................................. '��� — ........... SYMBOL DESCRIPTION MANUFACTURER MODEL NOZZLE DETAIL E 3 S 2 \ ` u OUTLETSi ! O ............................................ ........................................... ............................................ O ! W E ica 4"POP-UP SPRAY HEAD RAIN BIRD 1804-SAM-PRS 12H A/L5.02 ::::::..................:::::::::::::::: o bA \\ \\ is LLI d 4"POP-UP SPRAY HEAD RAIN BIRD 1804-SAM-PRS 15H A/L5.02Ln ...............................................\ . I O N ii O 4"POP-UP SPRAY HEAD RAIN BIRD 1804-SAM-PRS 15Q A/L5.02 ............................................ ........................................... ............................................ I n C) II�III E i 00 c N ............................................... L ^o J 'C d 4"POP-UP SPRAY HEAD RAIN BIRD 1804-SAM-PRS 15VAN A/L5.02CL o C 00 ................................................................................................. .....................................?i c tw d 4"POP-UP SPRAY HEAD RAIN BIRD 1804-SAM-PRS 18VAN A/L5.02 z N FUTURE ; L...................................... f �+ DRIPbJD VALVEs BUILDING ........................................... W ....;.... .... I 4,550 S.F. t ................................................................................................. .................................................€ XCZ-100-PRB-COM DRIP ZONE KIT WITH 100-PEB CONTROL DRIP CIRCUIT CONTROL VALVE RAIN BIRD F/L5.02 VALVE AND BASKET FILTER :............................................... V) o • .0 WITH BUILT-IN PRV N � ......................................................... �; C, W W ............................................... _ N i ` V E LAWN CIRCUIT CONTROL VALVE RAIN BIRD 100-PESB E/L5.02 € : :................................................ :t ) c� L ���� E '•€ ............................................... I� Vu T �_� U w a ............................................ .................................... i c ............................................... € Z _ Vf! LU s ............................................................................................... ............................................ _ IRRIGATION CONTROLLER Rain Bird(R) ESP-LXME Controllers G/L5.03 \ O :............................................... J N V cn Lu oC a ............................................ I 000 .................................... W > II '�I - - _ Z 0 -- --- .-.-.-.-.- �...-.- -- --- -- ---- -- -- --__ - -----------------------------------------; p a !CONCRETE PAD FOR BACKFLOW C/L5.03 PREVENTER ..................... ........................ 1 2 © J I! Q ......::.: 6.9 gpm 6.7 gpm ' L i POC QD Poc POINT OF CONNECTION A/L5.03 € € O i ............................................... I I •I. — — - - - - - ............................................ TYPE MATERIAL DETAIL PIPE I. ............................................ i i SCHEDULE 40 PVC PIPE WITH i [ SCHEDULE 40 PVC FTTINGS.1/2" 1"DRIP SUPPLY LINE RIGID DISTRIBUTION TUBING AND C/1-5.02 — O i ................................................ EMITTERS NOT SHOWN ON PLAN FOR GRAPHIC CLARITY. , — ............................................ • f SCHEDULE 40 PVC PIPE WITH 1"LATERAL LINE C/L5.02 I SCHEDULE 40 PVC FTTINGS. or IIETENT! N BASIN PROPOSED .4... ................. I Q Q BUILDING ! O 1"MAIN LINE SCHEDULE 40 PVC PPE WITH C/L5.02 FIFE = 2691.00' �_� ( B.O. I SCHEDULE 80 PVC FTTINGS 2,365 SQ.FT. I El �c DC 1 ., ! ; ............ - - W 3 o PIPE SLEEVE UNDER NEW PAVING SCHEDULE 40 PVC D/L5.02 J — F — i O L W f: .......... ..�, I 4 I Z C� U_ M i o U W ;i 5 0 :...................... RI \`.:':. Lu ::::::::... .. \\ .............................................................................................. s . _ ...... __ \ >. ........... .....—....—.............T........ .. RETENTION , , ................................./\-/ \ ......................................................................... ....................................................... BASIN s .RETENTION BASIN �� V f.. L. . .....................,_ ...................................... .. ...................... \.EMITTER SCHEDULE \\ \\ ....... ................................................................................................... _ �................ PLANT NAME DRIP EMISSION DEVICE DETAIL \ \ .................................................................................................. s M ACE OF HEARTS REDBUD TREE DRIP RING H/L5.02 ',• `�/ ` — 1— ————— T- : ! ALLEE LACEBARK ELM TREE DRIP RING H/L5.02 `•, � _ ---- — — __ _ _ .: _ �� HORSTMANN BLUE ATLAS CEDAR TREE DRIP RING H/L5.02 `---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- ----- ------------------------------------------------------------------------------------------------------ ROCKY MOUNTAIN GLOW MAPLE TREE DRIP RING H/L5.02 BLONDE AMBITION BLUE GRAMA GRASS 1 2-GPH EMITTER G/L5.02 - BLUE JEAN BABY RUSSIAN SAGE 1 2-GPH EMITTER G/L5.02 :::___::::___:::___::::___::____:::__:_:____::_::___:::_____:_:::__:_::_:_::_:__:_:_:___:::::___::::____:__::___:::____:_:__:___:___:::::___:::_____:__::___:::____:::__:_______:::::___: _ DWARF JAPANESE GARDEN JUNIPER 1 2-GPH EMITTER G/L5.02 FOERSTER'S FEATHER REED GRASS (1)2-GPH EMITTER G/L5.02 o VICTORY ROAD GRO-LOW FRAGRANT SUMAC 1 2-GPH EMITTER G/L5.02 JAKOBSEN MUGO PINE 1 2-GPH EMITTER G/L5.02 0 NEW MEXICO PRIVET (1)6-GPH EMITTER G/L5.02 SAPPHIRE BLUE OAT GRASS 1 2-GPH EMITTER G/L5.02 0 r i Z � O Z a OL) U) ) W 0 w W a 0 waaaaaaa PROJECT NO: 21070 DRAWN BY: TG CHECKED BY: SS AVOID CUTTING UNDERGROUND NORTH UTILITIES. ITS COSTLY. NOTICE! DATE: SEPTEMBER 2021 CallTHE CONTRACTOR SHALL BE 0 20 40 60 FT PROPERTY NO: RESPONSIBLE FOR THE LOCATION, BEFORE YOU PROTECTION,AND RESTORATION LANDSCAPE DIg OF ALL BURIED OR ABOVE GROUND UTILITIES,SHOWN OR <1 > IRRIGATION NOT SHOWN ON THE PLANS. PLAN 1-800-662-4111 L3m01 F TREE NOTES: NOTES: STAKES ROOFING NAIL 1. REFER TO"PLANTING ON SLOPE"DETAIL IF 1. REFER TO"PLANTING ON SLOPE"DETAIL IF NECESSARY. NECESSARY. z bO 7 2. AMENDED BACKFILL SHALL BE A BLENDED MIXTURE OF 2. AMENDED BACKFILL SHALL BE A BLENDED v 4 THREE(3)PARTS EXCAVATED SOIL OR IMPORTED TOPSOIL TREE MIXTURE OF THREE(3)PARTS EXCAVATED 3 wc s = AND ONE(1)PART WELL ROTTED COMPOSTED MANURE, SOIL OR IMPORTED TOPSOIL AND ONE(1) 0 E u ca NOTE: APPROVED COMMERCIAL MIX,OR OTHER AMENDMENT PART WELL ROTTED COMPOSTED MANURE, W �z Q RECOMMENDED IN TOPSOIL TESTING REPORT. FLEXIBLE STRAP APPROVED COMMERCIAL MIX,OR OTHER o CD 1.REFER TO"PLANTING ON O O o ° ° TREE TIE 1 (ONE) AMENDMENT RECOMMENDED IN TOPSOIL rLfi p_ 3,SLOPE"DETAIL IF NECESSARY. O 3. DO NOT PLANT IN HOLES THAT DO NOT DRAIN OR ° CONTINUOUS PIECE TESTING REPORT. tt Ln u PERCOLATE PROPERLY. o `V EXISTING SLOPE ° ° 3. DO NOT PLANT IN HOLES THAT DO NOT co 0 ° ° ° co DRAIN OR PERCOLATE PROPERLY. ° ° N o ° MULCH HOLD BACK 3"FROM o ro J O o BASE OF TRUNK `0 4. AT BASE OF EACH TREE WITHIN LAWN CL V, ca to 0 O � AREAS,LEAVE 36 INCH DIAMETER CIRCLE aq ° ° ° FREE OF ANY GRASS. • WATER RETENTION BERM 8'TREE STAKES 0 5. CONTRACTOR RESPONSIBLE TO REMOVE W .c MULCH.HOLD BACK MULCH.HOLD BACK o SET TOP OF ROOT BALL 2" STAKES AND TIES AT END OF ONE YEAR C L 3"FROM BASE OF PLANT 3"FROM BASE OF TRUNK ABOVE FINISH GRADE, o C WARRANTY PERIOD. � �� V O 2:1 TRANSITION SLOPE �; " o TRUNK FLARE MUST BE , _ SET TOP OF ROOT BALL 2" SET TOP OF ROOT BALL 2 VISIBLE ABOVE MULCH MULCH TAPER TO TRUNK � 0 •� M FINISH GRADE FINISH GRADE 0 W ABOVE FINISH GRADE ABOVE FINISH GRADE W FINISH GRADE AMENDED BACKFILL u N = PLANT PIT WITH ANGLED E � SIDES z jw AMENDED BACKFILL r_ J AMENDED BACKFILL ' PLANT PIT WITH ANGLED SIDES AMENDED BACKFILL PLANT PIT WITH ANGLED � c u O L REMOVE TOP 1/3 OF WIRE SIDES.ROUGHEN SIDES AND UNDISTURBED SOIL ROOT BALL BASKETAND BURLAP - w v ._ 4j BOTTOM OF EXCAVATION. PLANT PIT WITH ANGLED SIDES AND z W N SLOPED BOTTOM.ROUGHEN SIDES '> = V UNDISTURBED SOIL ROOT BALL UNDISTURBED SOIL ROOT BALL PLACED ON 2X ROOTBALL FOR CLAY SOIL-AUGER HOLE _ AND BOTTOM OF PIT. N UNDISTURBED SOIL 4'DEPTH AND BACKFILL WITH q SET TREE STAKE 12"INTO 2X ROOTBALL 2X ROOTBALL AMENDED TOP SOIL(AT NO UNDISTURBED SOIL,MINIMUM `O ADDITIONAL COST TO OWNER). J� i 00 2X ROOTBALL UNDISTURBED SOIL GRASSES AND PERENNIALS SHRUB PLANTING PLANTING ON SLOPE DECIDUOUS TREE A NO SCALE NO SCALE NO SCALE D N�OSCALE NOTES: FLEXIBLE STRAP NOTES: TREE TIE-1 (ONE) 1. REFER TO"PLANTING ON SLOPE"DETAIL IF NOTES: CONTINUOUS PIECE NECESSARY. A. LAYING OF SOD: 1. LAY SOD DURING GROWING SEASON AND WITHIN 48 HOURS OF BEING LIFTED. 1. APPLY PRE EMERGENT HERBICIDE TO SHRUB AND TREE 2. AMENDED BACKFILL SHALL BE A BLENDED 2. LAY SOD WHILE TOP 6 INCHES OF SOIL IS DAMP,BUT NOT MUDDY. SODDING DURING FREEZING TEMPERATURES OR OVER STAKES ROOFING NAIL GROUND COVER PLANTING AREAS AND GRASS-FREE MIXTURE OF THREE(3)PARTS EXCAVATED SOIL FROZEN SOIL IS NOT ACCEPTABLE. AREAS AT TREES IN LAWN PRIOR TO PLACEMENT OF OR IMPORTED TOPSOIL AND ONE(1)PART WELL 3. LAY SOD IN ROWS PERPENDICULAR TO SLOPE WITH JOINTS STAGGERED. BUTT SECTIONS CLOSELY WITHOUT WEED BARRIER FABRIC AND MULCH. ROTTED COMPOSTED MANURE,APPROVED OVERLAPPING OR LEAVING GAPS BETWEEN SECTIONS. CUT OUT IRREGULAR OR THIN SECTIONS WITH A SHARP KNIFE. COMMERCIAL MIX,OR OTHER AMENDMENT 4. LAY SOD FLUSH WITH ADJOINING EXISTING SODDED SURFACES. 2. PRE-EMERGENT SHALL BE"SURFLAN AS"(LIQUID)BY RECOMMENDED IN TOPSOIL TESTING REPORT. 5. DO NOT SOD SLOPES STEEPER THAN 3:1. CONSULT WITH ARCHITECT FOR ALTERNATE TREATMENT. UNITED PHOSPHORUS INC,TRENTON,NJ,OR TREE B. AFTER LAYING OF SOD IS COMPLETE: APPROVED EQUAL. 3. DO NOT PLANT IN HOLES THAT DO NOT DRAIN 1. ROLL HORIZONTAL SURFACE AREAS IN TWO DIRECTIONS PERPENDICULAR TO EACH OTHER. OR PERCOLATE PROPERLY. 2. REPAIR AND RE-ROLL AREAS WITH DEPRESSIONS,LUMPS,OR OTHER IRREGULARITIES. HEAVY ROLLING TO CORRECT I 3. INSTALL MULCH TO UNIFORM DEPTH AND RAKE TO IRREGULARITIES IN GRADE WILL NOT BE PERMITTED. o Q NEAT FINISHED APPEARANCE FREE OF HUMPS AND w 4. AT BASE OF EACH TREE WITHIN LAWN AREAS, 3. WATER SODDED AREAS IMMEDIATELY AFTER LAYING SOD TO OBTAIN MOISTURE PENETRATION THROUGH SOD INTO TOP 6 c NCHES OF TOPSOIL. DEPRESSIONS. o LEAVE 36 INCH DIAMETER CIRCLE FREE OF ANY X GRASS. a 8'TREE STAKES C) O 5. CONTRACTOR RESPONSIBLE TO REMOVE o MULCH SET TOP OF ROOT BALL 2" STAKES AND TIES AT END OF ONE YEAR M 0L ABOVE FINISH GRADE, q WARRANTY PERIOD. N FINISH GRADE TRUNK FLARE MUST BE "' VISIBLE ABOVE MULCH CONCRETE PAVING MULCH TAPER TO TRUNK CONCRETE PAVING I.J. m FINISH GRADE R STONE MULCH(SEE AMENDED BACKFILL SOD PLANT BARK OSCHEDULE FOR TYPE).HOLD O - - Z d DOWN 1"FROM TOP OF WALLS, m REMOVE TOP 1/3 OF WIRE - a - WALKS,AND CONCRETE PADS o ^ r , BASKET AND BURLAP PLANT PIT WITH ANGLED SIDES AND �J, V Q SLOPED BOTTOM. ROUGHEN SIDES TIGHT BEVELED JOINTS —W-Z5 _ co �e > AND BOTTOM OF PIT. WEED BARRIER FABRIC(REFER TO FOR CLAY SOIL AUGER HOLE r , SET TREE STAKE 12"INTO AMENDED TOPSOIL, PLANT SCHEDULE FOR TYPE) w V - _ �, 4'DEPTH AND BACKFILL WITH _ UNDISTURBED SOIL,MINIMUM 5"MIN.LAYER COMPACTED OR AMENDED TOP SOIL(AT NO UNNDIS URBED SUB GRADE ADDITIONAL COST TO OWNER). Q 2X ROOTBALL W UNDISTURBED SOIL EVERGREEN TREE SOD INSTALLATION MULCH BOULDER Q � E NO SCALE F NO SCALE G NO SCALE H NO SCALE N V / NOTES: 1.TOP OF WALL TO BE SET LEVEL AND NOT SLOPE WITH GRADE. 3/4"CHAMFER ON ALL 2.USE MASONITE FORMS TO PROVIDE SIDES OF TOP SMOOTH FINISH FREE OF WOOD CONTINUOUS GRAINS. 18" 3.DO NOT USE FORM TIES. PROVIDE EXTERIOR BRACING TO FORMS AS NEEDED. <-2%SLOPE ALL FACES OF CONCRETE ABOVE - - - - - - -° FINISH GRADE TO HAVE SMOOTH I #4 HORIZ.BARS CONT. Z ARCHITECTURAL FINISH FREE OF I- I AND#4 VERT.BARS @ 0 FORM LINES,WOOD GRAIN,AND I I 16"O.C.(ALL SIDES) vi Z a HONEY-COMBING I d - 4 a I 4 I 2"MIN.COVER FINISH GRADE O N 52 o I I' uj 1' I UNDISTURBED SOIL H I� OR COMPACTED FILL Q CD— a 12"DIAMETER W H<Haaa CONCRETE PIER W/ a I SONOTUBE @ 4'O.C. MAX. PROJECT NO: 21070 1 DRAWN BY: TG I (3)#4 J-BARS PER PIER CHECKED BY: SS 1 I DATE: SEPTEMBER 2021 PROPERTY NO: LANDSCAPE PLANTING CONCRETE SEATWALL DETAILS I SCALE: 1"=1' L5mOl F E NOTES: ° NOTES: NOTES: ao a. LOCATION OF HEADS AND PIPING SHOWN ON CONTRACT DRAWINGS IS APPROXIMATE. ACTUAL PLACEMENT MAY VARY SLIGHTLY z 1. SLEEVE WATER LINES AND CONTROL WIRES UNDER WALKS L i AS IS REQUIRED TO ACHIEVE FULL,EVEN COVERAGE WITHOUT SPRAYING ONTO BUILDINGS,SIDEWALKS,FENCES,ETC. 1. PULLING OF PIPE IS NOT PERMITTED. L a) 3 b. DURING LAYOUT,CONSULT WITH ARCHITECT TO VERIFY PROPER PLACEMENTAND MAKE RECOMMENDATIONS,WHERE AND PAVING. EXTEND SLEEVES 6 INCHES MINIMUM BEYOND b WALK OR PAVEMENT EDGE. COVER SLEEVE ENDS UNTIL v u N REVISIONS ARE ADVISABLE. 2. EXCAVATE TRENCHES TO SPECIFIED DEPTH. REMOVE ROCKS v c. MINOR ADJUSTMENTS IN SYSTEM LAYOUT WILL BE PERMITTED TO AVOID EXISTING FIXED OBSTRUCTIONS. LARGER THAN 1 1/2 INCH IN ANY DIRECTION FROM BOTTOM PIPES AND WIRES ARE INSTALLED TO KEEP SLEEVE CLEAN — 41 � AND FREE OF DIRT AND DEBRIS. 3 = !E = d. MAKE CERTAIN CHANGES FROM CONTRACT DOCUMENTS ARE SHOWN ON RECORD DRAWINGS. OF TRENCH. SEPARATE OUT ROCKS LARGER THAN 1-1/2 INCH IN 0 E u Ca e. LOCATE PIPE SO NO SPRINKLER HEAD WILL BE CLOSER THAN 12 INCHES(300 MM)FROM BUILDING FOUNDATION. ANY DIRECTION UNCOVERED IN TRENCHING OPERATION W � f. SET SPRINKLER HEADS PERPENDICULAR TO FINISH GRADE. FROM EXCAVATED MATERIAL AND REMOVE FROM AREAS TO 2. POSITION SLEEVES WITH RESPECT TO BUILDINGS AND Q OTHER OBSTRUCTIONS SO PIPE CAN BE EASILY REMOVED. o o g. DO NOT INSTALL SPRINKLERS USING SIDE INLETS. INSTALL USING BASE INLETS ONLY. RECEIVE LANDSCAPING. uj NEW PAVEMENT �- — h. HEADS IMMEDIATELY ADJACENT TO MOW STRIPS,WALKS,OR CURBS SHALL BE ONE INCH BELOW TOP OF MOW STRIP,WALK,OR � Ln W y CURB AND HAVE ONE INCH TO 3 INCH CLEARANCE BETWEEN HEAD AND MOW STRIP,WALK,OR CURB. 3. INSTALLA 2"MIN.LAYER OF ROCK-FREE SOIL OR SAND UNDER THE z o �`! PIPE AND ON ALL SIDES. REMAINDER OF BACKFILL TO THE TOPSOIL V) o 5"DEEP MIN.TOPSOIL LAYER SHALL BE SOIL NATIVE TO THE PROJECT SITE FREE OF WOOD ' N LAYER IN LAWN AREAS AND OTHER DELETERIOUS MATERIALS AND ROCKS OVER 1-1/2 _ o J = COMPACTED SOILAROUND INCHES IN ANY DIRECTION. o 0 0 00 c J POP-UP SPRAY HEAD HEAD AND FLEX PIPE 2"HORIZONTAL SEPARATION by CONCRETE 4. DO NOT COVER PRESSURE MAIN, IRRIGATION PIPE,OR FITTINGS OQ �� OQD QD ) QOQO AGGREGATE BASE c, • FINISH 1"MIN FINISH UNTIL ARCHITECT HAS INSPECTED AND APPROVED SYSTEM. o 0 0 0 0 0 0 0 0 o p TbiD GRADE GRADE FINISHGRADE ,i z � 1/2" MARLEX = 3 V) STREET ELL COMPACTED BACKFILL .- • •d� N 1/2"BARBED ELL COMPACTED W — bQ W SPRINKLER HEAD � 0 � � BACKFILL o O SLEEVE-SIZE SHALL " PVC LATERAL LINE E (18"DEEP FOR ROTOR AND BE 2 TIMES DIAMETER o OF PIPE o C u IMPACT HEAD INSTALLATIONS) V ,y � ' PVC MAINLINE - L j 4j CONTROL WIRES TAPED - - CONDUIT FOR CONTROL ,� N TOGETHER AT 10'O.C.MAXIMUM. MAINLINE OR LATERAL LINE WIRES IN SEPARATE DO NOT TAPE TO MAINLINE PIPE SLEEVE-SIZE AS •> PVC LATERAL LINE 1/2"BARBED ELL AND INSTALL UNDER AND TO NEEDED. L ° V SCH.40 PVC W/1/2" 2"MIN.LAYER OF SAND THE SIDE OF THE MAINLINE 21"MIN. n BELOW AND ON ALL LINEAR LOW DENSITY THREADED OUTLET OR ROCK FREE SOIL PIPE. �I S o POLYETHYLENE PIPE TRENCH WIDTH 21" / 14"LONG MINIMUM SIDES OF PIPE MINIMUM TO ALLOW FOR 24"LONG MAXIMUM COMPACTION TO 95% SPRAY HEAD ASSEMBLY SPRINKLER HEAD NEXT TO PAVING TRENCH TRENCH UNDER NEW PAVEMENT A BfNOC D �NO SCALE SCALE NOTES: NOTES: 1. LIMIT(2) 1"VALVES PER VALVE BOX AND(1) 1. LIMIT(1)DRIP VALVE ASSEMBLY PER BOX 1-1/2"OR 2"VALVE PER BOX 2. INSTALL GREEN COLORED VALVE BOXES AND WATERPROOF WIRE CONNECTIONS 2. INSTALL GREEN COLORED VALVE BOXES AND LIDS IN THE LAWN AREAS AND TAN COLORED LIDS IN THE LAWN AREAS AND TAN COLORED BOXES AND LIDS IN THE PLANTING BEDS 24"LINEAR LENGTH OF WIRE,COILED BOXES AND LIDS IN THE PLANTING BEDS AUTOMATIC VALVE-SEE IRRIGATION LEGEND FOR TYPE AND SIZE 3. ALL FITTINGS WITHIN VALVE BOX SHALL BE DRIP CIRCUIT CONTROL VALVE-SEE 3. ALL FITTINGS WITHIN VALVE BOX SHALL BE SCH.80 PVC AND SAME SIZE AS THE VALVE ID TAGS IRRIGATION LEGEND SCH.80 PVC AND SAME SIZE AS THE VALVE ID TAGS SCH.80 PVC"ACTION"FITTING UNION ON BOTH SIDES OF CONTROL VALVE. INSTALL 4. CONTRACTOR TO REPLACE EXISTING 200 SCH.80 PVC"ACTION"FITTING UNION ON BOTH FINISH GRADE TRANSITION FITTINGS AS NEEDED MESH(WHITE)SCREEN WITH ANEW 100 SIDES OF CONTROL VALVE AND PRV/FILTER MESH(RED)SCREEN FINISH GRADE NIBCO BRASS GATE VALVE WITH NIBCO BRASS GATE VALVE WITH HANDWHEEL Q WATERPROOF WIRE CONNECTIONS HANDWHEEL TOP-SAME SIZE AS MAINLINE TOP M PLASTIC VALVE BOX 12" < < 24"LINEAR LENGTH OF WIRE,COILED SCH.80 PVC NIPPLE-LENGTH AS DEEP STANDARD SCH.80 PVC NIPPLE-LENGTH AS O NEEDED NEEDED Q PLASTIC VALVE BOX 12"DEEP STANDARD 0 PRESSURE REGULATOR AND SCH.80 PVC FEMALE ADAPTER QUICK-CHECK BASKET FILTER SCH.40 PVC LATERAL LINE � 0 < 0 SCH.80 PVC THREADED ELBOW SCH.40 PVC LATERAL � FLOW 0 0 SCH.80 PVC THREADED ELBOW w � Q LINE PRECAST CONCRETE PAVER, M O ( PRECAST CONCRETE PAVER STANDARD MSCH.80 SCH.80 PVC NIPPLE-LENGTH AS NEEDED BRICK SIZE) o o NEE EDPVC NIPPLE LENGTH AS (STANDARD BRICK SIZE) o 0 0 0 o z Q 3/4"WASHED GRAVEL,6"MINIMUM DEPTH 3 CLEARANCE BETWEEN 3/4"WASHED GRAVEL,6"MINIMUM DEPTH " U 3"CLEARANCE BETWEEN GRAVEL AND � � � � o 0 0 BOTTOM OF VALVE SCH.80 PVC THREADED GRAVEL AND BOTTOM OF VALVE SCH.80 PVC THREADED Q ELBOW ELBOW TAPE CONTROL WIRES TO MAINLINE SCH.80 PVC NIPPLE INTO MAINLINE SCH.40 PVC MAIN LINE SCH.T PVC NIPPLE INTO MAINLINE FITTING, r , w EVERY 10' FITTING-LENGTH AS NEEDED LENGTH AS NEEDED v �^ 5 SCH.40 PVC MAINLINE SCH.80 PVC FITTING WITH THREADED OUTLET SCH.80 PVC FITTING WITH THREADED OUTLET D V J G TAPE CONTROL WIRES TO MAIN LINE ry W EVERY 10' CONTROL VALVE - LAWN CIRCUIT CONTROL VALVE - DRIP CIRCUIT Q � E F NO SCALE ` V U) co NOTES: NOTE: FITTINGS TO INLINE DRIP TUBING TO BE INSERT FITTINGS. USE OETICKER CLAMPS FOR NON-NETAFIM FITTINGS. 1. THREADED EMITTER SHALL BE FROM GPH IRRIGATION PRODUCTS MODEL GPSTCV SPEC-CHECK PC"DESERT CAMO"COLOR FOR ROCK AREAS AND"MULCH / CAMO"COLOR FOR BARK MULCH AREAS. / \ / ADDITIONAL IN-LINE EMITTER TUBING IF USED 2. SEE EMITTER SCHEDULE ON IRRIGATION PLAN FOR QUANTITY AND SIZE OF EMITTERS PER PLANT. / FOR LARGE NEW TREES OR EXISTING TREES. � PLACE DRIP LINES AT 2'-0" INTERVALS TO EDGE OF DRIP LINE OF TREE 3. INSTALL MAX.OF(6)EMITTERS PER PVC CONNECTION. __— T=_;— \ 4. DISTRIBUTION TUBING SHALL BE INSTALLED A MINIMUM OF 12"BELOW FINISHED GRADE AND ONLY BE BROUGHT TO THE SURFACE AT EACH PLANT. THREADED EMITTER-SEE NOTES 1 &2 ABOVE. o o 0 i i I I \ \ O BOTTOM OF EMITTER TO BE FLUSH WITH TOP 0i i I I vi H OF MULCH. 2411 �� 24" 12lo II �� TREE Z 0- o o _ _ _ THREADED EMITTER-SEE i I 1 FR /�' \� /�I \� /�I \ NOTES 1 &2 ABOVE.INSTALL 6" Il ROOT BALL IN-LINE EMITTER TUBING STAPLED ON TOP O L) 1/2"BARBED FITTING WITH BLACK MALE PLANT \ \ \ MAX. FROM CENTER OF PLANT OF FINISH GRADE. INSTALL IN-LINE EMITTER LLI ADAPTER o PLANT / (� 1 1 1 1�11 I TUBING UNDER WEED BARRIER FABRIC WITH D p �``,I 1 I I MULCH PLACED ON TOP. NO KINKS IN LINE. IUJI 1/2"FUNNY PIPE DISTRIBUTION I I I I I I NOTE: FOR EVERGREEN TREES, LOCATE 1 / FINISH GRADE OF SOIL MULCH �� i/ i/ i _ TUBING(14"-48"LONG) I 1 1 GPH 1 1 �i� I ( ) ��� ��/ INDICATOR EMITTER ON OUTSIDE OF OUTER INDICATOR DRIP RING.) W 1/2"FUNNY PIPE DISTRIBUTION / \ \ / — \ EMITTER INTO TUBING AS NEEDED TO SUPPLY 1 1 Q ROOTBALL I � I IN-LINE EMITTER �� MULTIPLE PLANTS ROOTBALL J ' 1 �— ' 1 / I TUBING AT BASE OR TREE 1/2"BARBED COUPLER 1/2"BARBED COUPLER 1/2"BARBED FITTING WITH __ PVC TO PE PIPE PROJECT NO: 21070 BLACK MALE ADAPTER,TYP. \ —-—1 I=—— / CONNECTION II DRAWN BY: TG SxSxTH SCH.40 PVC TEE 1#2"BARBED TEE,TYP. \ I I CHECKED BY: SS TURNED ON ITS SIDE-SEE 1/2"FUNNY PIPE SxSxTH SCH.40 PVC TEE I I PVC LATER�kL LINE (12" NOTE 3 DISTRIBUTION TUBING TURNED ON ITS SIDE-SEE \ I I DEEP) / DATE: SEPTEMBER 2021 1/2"BARBED FITTINGS (14"-48"LONG)-SEE NOTE 3 PVC DRIP SYSTEM SECTION VIEW NOTE 4 PLAN SUPPLY LINE INSTALL IN-LINE \ I I PROPERTY NO: A NEEDED EMITTER TUBING WITH VIEW EMITTERS SPACED i ' LANDSCAPE EVENLY ON TOP OF — — — — ROOT BALL IRRIGATION DRIP EMITTER — DETAILS H TREE DRIP SYSTEM PLAN VIEW G NO SCALE NO SCALE L5mO2 F E 0 WILKI NOTE: ALUMINUM ENCLOSURE FROM ALLSPEC NOTE: ENCLOSURES INC.APPLY POWDER PREVENTION MODEL REDUCING THEFT ENCLOSURE INDEXG v L. THE POINT OF CONNECTION DETAIL IS FINISH GRADE INSTALL GREEN COLORED VALVE COATED COLOR AS FOLLOWS: PRESSURE PRINCIPLE L °' 3 SCHEMATIC ONLYAND MEANT TO CONVEY THE BOXES AND LIDS IN LAWN AREAS ASSEMBLY BACKFLOW ENCLOSURE AGE-SETTER ONCRETE s 40 o b ORDER OF THE COMPONENTS.ACTUAL LAYOUT AND TAN COLORED BOXES AND WITHIN BARK MULCH PLANTING BEDS=BROWN PREVENTER SIZE MODEL NUMBER MODEL NUMBER PAD SIZE v Q MAY VARYAND SHOULD BE COORDINATED AS LIDS IN PLANTING BEDS. WITHIN ROCK MULCH PLANTING BEDS=TAN /4" BFESD-AL-2424 SSS-2424 4"W x 36"L 3 -T 41 s = WITHIN LAWN AREAS=DARK GREEN BRASS NIPPLE ON 1" BFESD-AL-3024 SSS-3024 4"W x 42"L 0 E NEEDED PRIOR TO INSTALLATION. ° BOTH SIDES c E i Ca B o 0 10"ROUND VALVE BOX 1-1/4" BFESD-AL-3630 SSS-3630 0"W x 48"L � Q 1"STOP&WASTE VALVE L5.03 3/4"WASHED GRAVEL BRASS 90'ELBOW ON 1-1/2" BFESD-AL-4230 SSS-4230 0"W x 54"L W C. 4) WITHIN BOX AND O BOTH SIDES '� 0 0 2"SCH.40 PVC PIPE BFESD-AL-4230 SSS-4230 0"W x 54"L Ln UNDER BLOCKS z m c Ln NOTCHED OVER MAINLINE � ,I\ c ci BRASS � ONCRETE DEPTH o _ us 1"BACKFLOW PREVENTION C SC.80 MALE ADAPTER FITTING SEALANT NIPPLE MARKER NOTCH � N L5.03 ASSEMBLY PRECAST CONCRETE PAVERI. O O -1 ° ro J '� / / _ (STANDARD BRICK SIZE) SCH.40 PIPE WITH SCH. LOCKING DEVICE BRASS \ - ca E 80 PVC FITTINGS TO FINISH GRADE UNION / \ / \ tw J CONNECT INTO THE ISOLATION VALVE FILTER ASSEMBLY HINGE z EXISTING BUILDING L5.03 FLOW I — — — \ L SUPPLY LINE ON THE I �T � - - -� L - - - 1T� I � •L C OUTLET SIDE OF THE BRASS STOP AND WASTE BRASS ELL - , n 4 CONCRETE PAD LJ / \ LJ / N C WATER METER AS PER ALL POC VALVE-PLUMB TO 40"DEEP IF CONCRETE PAD SURFACE \ \ o V APPLICABLE PLUMBING BF D MAINLINE TO REMOTE WATER SUPPLY LINE IS DEEPER — \ / \ / �„ CA CODES AND REGULATIONS CONTROL VALVESbiD N W BRASS ELL I I BRASS ELL V D D E L5.03 MANUAL DRAIN VALVE BRASS NIPPLE- L5.03 PVC SLEEVE PVC SLEEVE o CONCRETE PAD o ° LENGTH AS REQUIRED O BRASS NIPPLE 6" 6" 6" \ \ V o c u 0 0 o BRASS NIPPLE,8"MIN. MANUAL DRAIN VALVE AS BRASS 6 w T �= i WATER SUPPLY LINE O LENGTH NEEDED IF MAINLINE NIPPLE - - - _-- ___ _________________________________ __ _ MANUAL DRAIN VALVE � \ t c W 0 0 o CANNOT BE DRAINED BACK � _ricn — N FILTER FABRIC TO STOP AND WASTE VALVE / D —— —— > 3/4"WASHED GRAVEL SUMP, F 12 Wx12 Wx24 D \_�/ FLOl�1 FL \_// L5.03 END VIEW SIDE VIEW QUICK COUPLER FOR BLOW OUT L5.03 � PIPE, FITTINGS& LINE FROM i 00 NECESSARY ADAPTERS WATER SOURCE FROM STOP AND WASTE BRASS 90'ELBOW CAGE - SETTER VALVE(LENGTH AS POC SCHEMATIC LAYOUT STOP & WASTE VALVE REQUIRED) BACKFLOW PREVENTER (A � C NO SCALE FINISH GRADE NOTE: NOTES: NOTE: INSTALL GREEN COLORED VALVE 1. ALL PVC FITTINGS AND PIPE SHALL BE INSTALL GREEN COLORED VALVE BOXES AND LIDS IN LAWN AREAS SCH.80 PVC AND THE SAME SIZE AS BOXES AND LIDS IN LAWN AREAS AND TAN COLORED BOXES AND THE MAINLINE. AND TAN COLORED BOXES AND 0 LIDS IN PLANTING BEDS. LIDS IN PLANTING BEDS. 3/4"WASHED GRAVEL 2. INSTALL 2"CLASS 200 PVC SLEEVE OVER FINISH GRADE WITHIN BOX AND BRASS ISOLATION VALVE WHEN BRASS BRASS SWIVEL HOSE ELL UNDER BLOCKS 10"ROUND VALVE BOX VALVE IS AT DEPTH OF 18"OR DEEPER. Q RUBBER COVER 0 0 0 BRASS KEY PRECAST CONCRETE PAVER(STANDARD o PRECAST CONCRETE PAVER 10"ROUND VALVE BOX FINISH GRADE BRICK SIZE) (STANDARD BRICK SIZE) Q BRASS TWO PIECE BODY DESIGN 2"SCH.40 PVC PIPE SCH.80 PVC FEMALE ADAPTOR ON QUICK COUPLER VALVE NOTCHED OVER DRAIN VALVE BOTH SIDES OF ISOLATION VALVE NIBCO BRASS GATE VALVE Q O AS NEEDED MATCH MAINLINE SIZE WITH HANDWHEEL TOP(MATCH 10"ROUND VALVE BOX FILTER FABRIC MAINLINE SIZE) 3/4"WASHED GRAVEL WITHIN WITH EXTENSIONS BOX AND UNDER BLOCKS 3/4"GALVANIZED 3/4"WASHED GRAVEL WITHIN STREET ELL BOX AND UNDER BLOCKS. GALVANIZED ELL GALVANIZED STEEL NIPPLE � � Q O o o WATER SUPPLY LINE O 3/4"MARLEX STREET ELL 3/4"MARLEX STREET ELL LENGTH AS NEEDED PVC MAINLINE OR NIPPLE O 0 0 0 0 3/4"GALVANIZED NIPPLE AS NEEEDED o o PRECAST CONCRETE PAVER 7 4"MIN.LENGTH SCH.80 PVC THREADED NIPPLES (STANDARD BRICK SIZE) Z 2"SCH.40 PVC PIPE BOTH SIDES OF UNION-MATCH SCH.80 PVC UNION-NIPPLE o U^ (v) Q 3/4"BRASS DRAIN VALVE NOTCHED OVER DRAIN MAINLINE SIZE LENGTH AS NEEDED TO �J, SCH.80 PVC FITTING WITH REMOVE UNION NUT oQ THREADED OUTLET O O 3/4"WASHED GRAVEL AND W/SLOTTED TOP VALVE GALVANIZED STREET ELL 0 0 0 0 0 o SCH.80 PVC UNION-NIPPLE SUMP(SUMP SIZE 12"xl2"xl2") LENGTH AS NEEDED TO THREADED END03/4"GALVANIZED REMOVE UNION NUT CONNECTIONS(BOTH SIDES) SCH.40 PVC MAIN LINE GALVANIZED STREET ELL w STREET ELL o o o o GALVANIZED NIPPLE �J� ) LENGTH AS REQUIRED SCH.80 PVC FITTING W/ M Q SECTION VIEW TOP VIEW THREADED OUTLET ry w MAINLINE DRAIN VALVE ISOLATION VALVE - THREADED QUICK COUPLER VALVE Q V) D E F N U IRRIGATION CONTROLLER METAL ELECTRICAL FIRMLY SECURE JUNCTION BOX CONTROLLER TO WALL THREADED CONNECTOR TO Z SURGE BOTTOM OF CONTROLLER 0 H SUPPRESSOR Z OL) U) W q RIGID STEEL CONDUIT LOCATED NEXT TO WALL AND SECURELY FASTENED W W Q 0 FINISH GRADE FLOOR Lu a a a a a a a PROJECT NO: 21070 RIGID STEEL CONDUIT SWEEP DRAWN BY: TG ELBOW, 12"RADIUS MIN. CHECKED BY: SS DATE: SEPTEMBER 2021 PROPERTY NO: LANDSCAPE IRRIGATION CONTROLLER DETAILS G L5mO3