Loading...
Z - Signed Order BEFORE THE MERIDIAN CITY COUNCIL HEARING DATE: OCTOBER 5, 2021 ORDER APPROVAL DATE: OCTOBER 19, 2021 IN THE MATTER OF THE ) REQUEST FOR FINAL PLAT ) CONSISTING OF THREE (3) ) CASE NO. FP-2021-0037 BUILDING LOTS ON 2.88 ACRES ) OF LAND IN THE C-C ZONING ) ORDER OF CONDITIONAL DISTRICT FOR INGLEWOOD ) APPROVAL OF FINAL PLAT SUBDIVISION NO. 2. ) BY: MCNEIL ENGINEERING ) APPLICANT ) This matter coming before the City Council on October 5, 2021 for final plat approval pursuant to Unified Development Code (UDC) I 1-613-3 and the Council finding that the Administrative Review is complete by the Planning and Development Services Divisions of the Community Development Department, to the Mayor and Council, and the Council having considered the requirements of the preliminary plat, the Council takes the following action: IT IS HEREBY ORDERED THAT: 1. The Final Plat of"PLAT SHOWING INGLEWOOD SUBDIVISION NO. 2, LOCATED IN THE SW 1/4 OF THE SW 1/4 OF SECTION 21, TOWNSHIP 3 NORTH, RANGE I EAST, BOISE MERIDIAN, CITY OF MERIDIAN, ADA COUNTY, IDAHO, APRIL 2021, HANDWRITTEN DATE: 09/28/2021, by ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT FOR INGLEWOOD SUBDIVISION NO. 2 FP-2021-0037 Page I of 3 Page 95 Michael D. Hoffman, PLS, SHEET I OF 2," is conditionally approved subject to those conditions of Staff as set forth in the staff report to the Mayor and City Council from the Planning and Development Services divisions of the Community Development Department dated October 5, 2021, a true and correct copy of which is attached hereto marked"Exhibit A" and by this reference incorporated herein. 2. The final plat upon which there is contained the certification and signature of the City Clerk and the City Engineer verifying that the plat meets the City's requirements shall be signed only at such time as: 2.1 The plat dimensions are approved by the City Engineer; and 2.2 The City Engineer has verified that all off-site improvements are completed and/or the appropriate letter of credit or cash surety has been issued guaranteeing the completion of off-site and required on-site improvements. NOTICE OF FINAL ACTION AND RIGHT TO REGULATORY TAKINGS ANALYSIS The Applicant is hereby notified that pursuant to Idaho Code § 67-8003, the Owner may request a regulatory taking analysis. Such request must be in writing, and must be filed with the City Clerk not more than twenty-eight(28) days after the final decision concerning the matter at issue. A request for a regulatory takings analysis will toll the time period within which a Petition for Judicial Review may be filed. ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT FOR INGLEWOOD SUBDIVISION NO. 2 FP-2021-0037 Page 2 of 3 Page 96 Please take notice that this is a final action of the governing body of the City of Meridian,pursuant to Idaho Code § 67-6521. An affected person being a person who has an interest in real property which may be adversely affected by this decision may, within twenty- eight(28) days after the date of this decision and order, seek a judicial review pursuant to Idaho Code§ 67-52. By action of the City Council at its regular meeting held on the 19th day of October , 2021. By: Robert E. Simison - - 2021 Mayor, City of Meridian Attest: Chris Johnson 10-19-2021 City Clerk Copy served upon the Applicant,Planning and Development Services Divisions of the Community Development Department and City Attorney. By: Dated: 10-19-2021 ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT FOR INGLEWOOD SUBDIVISION NO. 2 FP-2021-0037 Page 3 of 3 Page 97 EXHIBIT A STAFF REPORTC�WE COMMUNITY DEVELOPMENTDEVELOPMENT DEPARTMENT f D A H 0 HEARING 10/5/2021 Legend - 1� DATE: ff I i�cofl��, TO: Mayor&City Council FROM: Sonya Allen,Associate Planner 208-884-5533 SUBJECT: FP-2021-0037 ' Inglewood No. 2—FP LOCATION: 3220 E.Victory Rd., in the SW 1/4 of Section 21,T.3N.,R.1E. CM I. PROJECT DESCRIPTION Final plat consisting of three(3)buildable lots on 2.88 acres of land in the C-C zoning district. This is the second of two phases of development for this project. II. APPLICANT INFORMATION A. Applicant/Owner: Cody Williams,McNeil Engineering—8610 Sandy Parkway, Ste. 200, Sandy,UT 84070 B. Owner: Jim Petersen,Gold Stream, LLC— 197 West 4860 South, Salt Lake City,UT 84107 C. Representative: Same as Applicant III. STAFF ANALYSIS Staff has reviewed the proposed final plat for substantial compliance with the preliminary plat and associated conditions of approval as required by UDC 11-6B-3C.2. There are six(6)buildable lots shown on the approved preliminary plat vs. three(3)buildable lots shown on the proposed final plat. Because the number of buildable lots did not increase, Staff finds the proposed final plat is in substantial compliance with the approved preliminary plat as required. Page 1 Page 98 IV. DECISION A. Staff- Staff recommends approval of the proposed final plat with the conditions of approval in Section VI of this report. V. EXHIBITS A. Preliminary Plat(date: 8/27/2019) IM PRELIMINARY PLAT FOR -. 7{' INGLEWOOD PLACE SUBDIVISION JU 5 *; HIPt k1W MNff r-OSDISE VEDIRN tram . `" 'PRQIEGT$VTE .71 7-1 4 sITE oaTn I - oa"" d v»r..>� cwa�xsmer� LL" vim•• .�rvluux�urnx &$ _._.. ei.®.. SNEET INOE% cv. E. �.v'..1Y e.eL e.Poox oiAsm[[r urnnmo — �mwm mmxn nrm.i ura.mv .. � r �.e aawse��os � o ....��.... •• r „ TM PHASING R Z LGNING 1a-VMPP Bi 0 06 ME MDLOTS MMPRY usuirto - \`\\��`` ��"� SI.I Z LU � EL O _ ����x�� .x..�:. ,.�. m„�„ .®..� ,�� .,,.:e,,. ,..,� loop xu ra�l`ffl''ueov.�• _ LU CO.O Page 2 Page 99 B. Final Plat(date: 4/6/2021) n� e Y II 2 il ------------------- �� LIIhTCr o N � ■r:�arra4 ----- " I I � t.L I I ' II . I I I I I� I h , I m \f• � I v ��� Si!'1Nm'e Ynh' M��■f I - 79s Z I �'Jr Us• 1 F fa e PEI 1 ' r� I P$ s 4 ►Y}Y 5 � III �,� �y t I IIlm I .i ' PL4 �+ � Iwrll 1y�� M1�'^eiYAr[II I � I k lsj Its ------------------- Fi !Al m a ------—-- ----- -—..a.'------- - - --- - ! R i l-w E ticTT1Nf Im >s pr�n�PncPop Page 3 Page 100 INGLEWOOD SUBDIVISION NO.2 _ 0 SURVEYORS CERTIFI CATE SURVEY NARRATIVE crxucxa BOUNDARY DESCRIPTION APPROVAL OF THE CITY ENGINEER -- �:ro�x ur�r amsxe x�x uewoux rove arm ere ex vcme�orvxe reeen mr�.evnr. ,ri xi APPROVALOF THE CITY COUNCIL NOTES - -_ exnwti un caunx, Imo�xno„. xE �nm x Pu. a. 13889 - -r r>srvs een'A s - 9.ssrrsa= -- - cnruerx-xunoux,ioano wm Q - sao cry.n I A oisr�a®nmr�mm s -c, ec,. ,,sr .osr nr CERTIFICATE OF COUNTY SURVEYOR . mxrNns.xas.msa H,oxzx-eA:,rees. 1— o,vocxsexo-+OWNERS CERTIFICATE ACKNOWLEDGEMENT orrawococensunrwm mewxnaxowmers. m xe sveovoeo xro eroarsnxo�ms.Nom eenex_n..ex aoxx u. - - - _ _ CERTIFICATE OF COUNTY TREASURER A H7=son o1F=rxcn,r ---- cEo,o xE„w,ms,soz­XE rev�rFn.cor.m mFwsureexxrxo rax,xE mux..of rrw s,.,m rax­x. a xca+�rExrs or rc.So- mixoccrnc _En x , r•..s,r. ..n,nv..•� .,erer ram emuEww.rzx- xrruwo wxo nn,ko ur sexm�s cexnr unox svAuo mx ms xexrix rv�soFwrsor�r. o IN •uc.,6 -- ___- -- - _-_- r+E.vxxcx, RECORDERS CERTIFICATE uHEALTH CERTIFICATE �xnn x,ur misw=,xr.rsxr mexwusl�n ws reell11 ar mxx corms nne m r rwrere 11 rvve ixeoo a a-aursns nnse �~ IN sccmx xirsy noww oewm t�,ar':ncw rscae ---- ---- - - - - - - - mca.iss,w,ceorncexnrium orocwvu ADA COUNTY HIGHWAY DISTRICT COMMISSIONERS ACCEPTANCE s,Rc• GOLD STREAM PARTNERS LLe. rnuxirmrvrw.risxoxexs ox rrc_oare a: rme — 41*M NEIL ENGINEERING' SHEET sew,sxa rr.-...wm ms w„w yr xx.n«rx...eex.sr z OF �'•Clxil EnSnm V•CmuuIftZIr..1mg.ArWrY- z Sbueda�i En�neafhr('L.W SurveyIrq A HDS Page 4 Page 101 C. Landscape Plan(date: 8/17/2021) f e �... •�LANDSCAPE SCHEDULE mew .•w.......• e ...• REFERENCE NOTES Z E e z Lora Z. i at,EwiuccvE: °< I••uvE m mwn..w »bwwu w . d • ®�.m. .w.m o® Z ❑ LOT.2 z mr� .,,m.• ... Qw�..w� �.n.w�w. a ..�w..•. m. _O �❑ ff@ in Ua SITE AMENITY SCHEDULE . � 0 _ 0 0 • . v,..awrc.0 ®ua'�..m •.�ywx..° .exv,°za rLj C) MERMI CrtY DATA rc e VICTORY Roan d nCallaI M�,PE — L2.00 Page 5 Page 102 VI. CITY/AGENCY COMMENTS & CONDITIONS A. Planning Division Site Specific Conditions: 1. Applicant shall comply with all previous conditions of approval associated with this development [H-2019-0090(DA#2019-124424)]. 2. The applicant shall obtain the City Engineer's signature on the final plat within two(2)years of the City Engineer's signature on the previous phase final plat(by May 4, 2023)in accord with UDC 11-6B-7 in order for the preliminary plat to remain valid; or,a time extension may be requested. 3. Prior to submittal for the City Engineer's signature,have the Certificate of Owners and the accompanying acknowledgement signed and notarized. 4. The final plat shown in Section V.B prepared by Rob O'Malley,T-O Engineers, stamped on 2/18/2020 by, shall be revised as follows: a. Note #6: ". . . at the time of issuance of an individual building permits or- as-spay approved and/or-required, or-as shovi%en this p!W' b. Note#9: "Lots 1, 2, &4 3 are subject to a 41.00' foot right of way . . ." (there is no Lot 4 -replace 4 with 3) c. Note#10: "Lots 1 2;& 3-,,&-4 are subject to a 30.00 foot wide perpetual ingress/egress . . d. Note #11: "Access to E. Victory Road and S. Eagleis prohibited unless approved by Ada County Highway District and the City of Meridian." e. Note #12: "Lots shall not be reduced in size without prior approval from the health authority and the City of Meridian." f. Depict 25-foot wide street buffers along S.Eagle Rd.&E.Victory Rd. on a common lot(s) or on a permanent dedicated buffer(s), maintained by the property owner or business owner's association in accord with UDC 11-3B-7C. g. Remove the two (2)private streets (i.e. E. Alta Hills Ln., S. Falconers Ln. and E. Shergar Ln.)from the face of the plat.Private streets are not allowed to connect to an arterial street per UDC 11-3F-4A.2; these can be drive aisles. The private streets shown were not previously approved. h. Remove the parcel numbers from the face of the plat and all other non-survey related depictions/notes. See Final Plat checklist for items that need to be depicted on the plat. Please submit an electronic copy of the revised final plat with the application for City Engineer signature on the final plat. 5. The landscape plan shown in Section V.C, dated 8/17/21, prepared by McNeil Engineering, shall be revised as follows: a. Remove all trees&bushes from the street buffer along S.Eagle Rd.that are depicted within the 15-foot wide ingress-egress easement along the northern boundary of the site. b. Remove the private street names and the non-street buffer landscaping from the plan. Please submit an electronic copy of the revised landscape plan with the application for City Engineer signature on the final plat. Page 6 Page 103 6. Staff s failure to cite specific ordinance provisions or conditions from the preliminary plat and/or development agreement does not relieve the Applicant of responsibility for compliance. B. Public Works Site Specific Conditions: 1. A Street Light Plan will be required with the submittal of the civil construction plans and reviewed by the Transportation Coordinator prior to construction plan approval. 2. All water service lines require a meter setter. 3. Services should not cross lots other than those they serve,to avoid this from happening a water main may be required in Falconers Lane with services tapped for each lot off that main. 4. A water main stub should be provided to the north for a future service or fire line. General Conditions: 5. Sanitary sewer service to this development is available via extension of existing mains adjacent to the development. The applicant shall install mains to and through this subdivision; applicant shall coordinate main size and routing with the Public Works Department,and execute standard forms of easements for any mains that are required to provide service. Minimum cover over sewer mains is three feet, if cover from top of pipe to sub-grade is less than three feet than alternate materials shall be used in conformance of City of Meridian Public Works Departments Standard Specifications. 6. Water service to this site is available via extension of existing mains adjacent to the development. The applicant shall be responsible to install water mains to and through this development, coordinate main size and routing with Public Works. 7. All improvements related to public life,safety and health shall be completed prior to occupancy of the structures. Where approved by the City Engineer, an owner may post a performance surety for such improvements in order to obtain City Engineer signature on the final plat as set forth in UDC 11-5C-3B. 8. Upon installation of the landscaping and prior to inspection by Planning Department staff,the applicant shall provide a written certificate of completion as set forth in UDC 11-3B-14A. 9. A letter of credit or cash surety in the amount of 110% will be required for all incomplete fencing, landscaping, amenities,pressurized irrigation,prior to signature on the final plat. 10. The City of Meridian requires that the owner post with the City a performance surety in the amount of 125% of the total construction cost for all incomplete sewer, water infrastructure prior to final plat signature. This surety will be verified by a line item cost estimate provided by the owner to the City. The applicant shall be required to enter into a Development Surety Agreement with the City of Meridian. The surety can be posted in the form of an irrevocable letter of credit, cash deposit or bond. Applicant must file an application for surety, which can be found on the Community Development Department website. Please contact Land Development Service for more information at 887-2211. 11. The City of Meridian requires that the owner post to the City a warranty surety in the amount of 20% of the total construction cost for all completed sewer, and water infrastructure for a duration of two years. This surety amount will be verified by a line item final cost invoicing provided by the owner to the City.The surety can be posted in the form of an irrevocable letter of credit, cash deposit or bond. Applicant must file an application for surety, which can be Page 7 Page 104 found on the Community Development Department website. Please contact Land Development Service for more information at 887-2211. 12. In the event that an applicant and/or owner cannot complete non-life,non-safety and non-health improvements, prior to City Engineer signature on the final plat and/or prior to occupancy, a surety agreement may be approved as set forth in UDC 11-5C-3C. 13. Applicant shall be required to pay Public Works development plan review, and construction inspection fees, as determined during the plan review process, prior to the issuance of a plan approval letter. 14. It shall be the responsibility of the applicant to ensure that all development features comply with the Americans with Disabilities Act and the Fair Housing Act. 15. Applicant shall be responsible for application and compliance with any Section 404 Permitting that may be required by the Army Corps of Engineers. 16. Developer shall coordinate mailbox locations with the Meridian Post Office. 17. All grading of the site shall be performed in conformance with MCC 11-1-4B. 18. Compaction test results shall be submitted to the Meridian Building Department for all building pads receiving engineered backfill,where footing would sit atop fill material. 19. The engineer shall be required to certify that the street centerline elevations are set a minimum of 3-feet above the highest established peak groundwater elevation. This is to ensure that the bottom elevation of the crawl spaces of homes is at least 1-foot above. 20. The applicants design engineer shall be responsible for inspection of all irrigation and/or drainage facility within this project that do not fall under the jurisdiction of an irrigation district or ACHD.The design engineer shall provide certification that the facilities have been installed in accordance with the approved design plans. This certification will be required before a certificate of occupancy is issued for any structures within the project. 21. At the completion of the project,the applicant shall be responsible to submit record drawings per the City of Meridian AutoCAD standards. These record drawings must be received and approved prior to the issuance of a certification of occupancy for any structures within the project. 22. Street light plan requirements are listed in section 6-7 of the Improvement Standards for Street Lighting (http://www.meridiancity.org/public_works.aspx?id=272). All street lights shall be installed at developer's expense. Final design shall be submitted as part of the development plan set for approval, which must include the location of any existing street lights. The contractor's work and materials shall conform to the ISPWC and the City of Meridian Supplemental Specifications to the ISPWC. Contact the City of Meridian Transportation and Utility Coordinator at 898-5500 for information on the locations of existing street lighting. 23. The applicant shall provide easement(s)for all public water/sewer mains outside of public right of way (include all water services and hydrants). The easement widths shall be 20-feet wide for a single utility, or 30-feet wide for two. The easements shall not be dedicated via the plat, but rather dedicated outside the plat process using the City of Meridian's standard forms. The easement shall be graphically depicted on the plat for reference purposes. Submit an executed easement(on the form available from Public Works), a legal description prepared by an Idaho Licensed Professional Land Surveyor, which must include the area of the easement (marked EXHIBIT A) and an 81/2" x 11" map with bearings and distances (marked EXHIBIT B) for review. Both exhibits must be sealed, signed and dated by a Professional Land Surveyor. DO NOT RECORD. Add a note to the plat referencing this document. All easements must be Page 8 Page 105 submitted,reviewed, and approved prior to signature of the final plat by the City Engineer. 24. Applicant shall be responsible for application and compliance with and NPDES permitting that may be required by the Environmental Protection Agency. 25. Any wells that will not continue to be used must be properly abandoned according to Idaho Well Construction Standards Rules administered by the Idaho Department of Water Resources. The Developer's Engineer shall provide a statement addressing whether there are any existing wells in the development, and if so,how they will continue to be used, or provide record of their abandonment. 26. Any existing septic systems within this project shall be removed from service per City Ordinance Section 9-1-4 and 9 4 8. Contact the Central District Health Department for abandonment procedures and inspections. 27. The City of Meridian requires that pressurized irrigation systems be supplied by a year-round source of water(MCC 9-1-28.C.1).The applicant should be required to use any existing surface or well water for the primary source. If a surface or well source is not available,a single-point connection to the culinary water system shall be required. If a single-point connection is utilized,the developer will be responsible for the payment of assessments for the common areas prior to development plan approval. 28. All irrigation ditches, canals, laterals, or drains, exclusive of natural waterways, intersecting, crossing or laying adjacent and contiguous to the area being subdivided shall be addressed per UDC 11-3A-6. In performing such work,the applicant shall comply with Idaho Code 42-1207 and any other applicable law or regulation. Page 9 Page 106