Loading...
ElevationsMAIN LEVEL 0' -0" T.O. PLATE -LOW 8' -1 1/8"8' - 1 1/8"GRADE RIDGE 12' - 11 1/2"T.O. PLATE -HIGH 11' -0 1/4" 4" METAL CORNER / DOOR TRIM POWER METER METAL DOOR WITH METAL FRAME 36" X 30" VENT MAIN LEVEL 0' -0" T.O. PLATE -LOW 8' -1 1/8" T.O. PLATE -HIGH 11' -0 1/4" 3 12 MAIN LEVEL 0' -0" T.O. PLATE -LOW 8' -1 1/8" 30 YR. ASPHALT SHINGLES (TYP. U.N.O.) REMOVABLE ROOF HATCH - SEE PLAN T.O. PLATE -HIGH 11' -0 1/4" MAIN LEVEL 0' -0" T.O. PLATE -LOW 8' -1 1/8" 4" METAL CORNER / DOOR TRIM (TYP.) REMOVABLE ROOF HATCH - SEE PLAN 8" HARDIE LAP SIDING (TYP.) BUILDING COLORS: BODY - ALPACA SW7022 TRIM/FASCIA - ELEPHANT EAR SW9168 DOOR - ELEPHANT EAR SW9168 VENTS - ALPACA SW7022 ROOFING - DK. CHARCOAL T.O. PLATE -HIGH 11' -0 1/4" 3 12 1X12 FASCIA W/ 2X10 SUB-FASCIA (TYP.) GENERAL NOTES 1. ALL SETBACKS AND EASEMENTS ARE TO BE LOCATED AND VERIFIED PRIOR TO CONSTRUCTION. 2. FINISH GRADE SHALL SLOPE AWAY FROM THE FND. 5% FOR THE FIRST 10-FT. AND 2% THEREAFTER. 2X10 SUB-FASCIA 2X10 ROOF JOISTS AT 24" O.C. T.O. PLATE SEE PLAN FOR DESIGNATED HEEL HEIGHTS 7/16" OSB SHEATHING W/ COMP. SHINGLES ON 15# FELT OR EQUIV. 8X16 SOFFIT VENT W/ 6X14 CUT (MIN.) 8'-0" O.C. 3/8" SMART SOFFIT H2.5A TIE OR SDWC-15450 SCREWS AS PER TRUSS CALC'S 1/2" (MIN.) GYPSUM WALLBOARD AT WALLS & CEILING 2X STUDS AT 16" O.C. MOISTURE BARRIER TO RUN BEHIND BLOCKING NOTCH ROOF JOIST TO SIT ON WALL TYP. 6" 2X PRESSURE TREATED PLATE W/ 1/2" DIA. X 10" ANCHOR BOLTS - SEE LATERAL PLAN FOR SPACING 4" CONCRETE SLAB ON 4" COMPACTED GRAVEL BASE APPROVED MOISTURE BARRIER OVER 7/16" OSB SHEATHING 2X4 STUDS AT 16" O.C. (2) #4 HORIZONTAL REBAR IN TOP & BTM. OF STEM WALL VERTICAL #4 REBAR AT 48" ON CENTER - CENTER IN WALL & EXTEND INTO SLAB 24" MIN. TRENCH FOOTING - SEE PLAN 2' - 0"(MIN.) 2' - 0" 14' - 0"12' - 0"12' - 0"14' - 0" 2 3 4 1 11 2 3068 S 1 1 8" 6' - 0"2' - 2"6' - 0"2' - 2"T.O. PLATE = 8'-1 1/8" T.O. PLATE = 8'-1 1/8" RAKE TOP OF WALL T.O. PLATE = 10'-10 1/4" RAKE TOP OF WALL T.O. PLATE = 10'-10 1/4" 14' - 0" 14' - 0"4' - 0"12' - 0"3 5 4' - 0"12' - 0"NO BOLTS 3' - 4"10 1/2" 4 5' - 0"9' - 0" TYP. 6" 6 1.0 1. DESIGN CRITERIA: 2018 IBC 2. THE CONTRACTOR SHALL REVIEW ALL THE INFORMATION IN THESE DRAWINGS AND REPORT ANY ERRORS OR DISCREPANCIES PRIOR TO START OF CONSTRUCTION. 3. THE CONTRACTOR SHALL REPORT ALL SITE CONDITIONS SUCH AS SOIL CONDITIONS, SITE PROFILES OR MATERIAL VARIANCES WHICH MAY EFFECT THE INTEGRITY OF THIS DESIGN. 4. SOIL BEARING PRESSURE 1500 PSF BASED ON IBC CODE MINIMUMS. OTHER CONDITIONS MAY REQUIRE SPECIAL PROVISIONS IN FOUNDATION DESIGN AND CONSTRUCTION. CONTRACTOR TO VERIFY W/ GEOTECHNICAL ENGINEER AS REQ'D PRIOR TO CONSTRUCTION. GENERAL NOTES:FOUNDATION NOTES: 1. ALL FOOTINGS ARE TO BE PLACED ON NATIVE SOIL 12" MINIMUM BELOW EXISTING GRADE OR ON STRUCTURAL FILL. ALL FOOTINGS SHALL HAVE A MINIMUM FROST DEPTH OF 24". NOTIFY ENGINEER OF ANY DISCREPANCIES. 2. SILL PLATE TO BE 2X4 PRESSURE TREATED D.F. WITH 1/2"Ø A.B. AT 6'-0" O.C. MAX. WITH 7" MIN. EMBEDMENT IN CONCRETE - TYPICAL EXCEPT AS REQUIRED BY SHEAR WALL PANELS - SEE PLANS FOR ADD'L INFO. 3. ALL WOOD WITHIN 1" OF CONC. OR 6" OF EXPOSED EARTH TO BE APPROVED TREATED WOOD OR REDWOOD AS REQUIRED. 4. CONTRACTOR SHALL VERIFY AND COORDINATE SIZES AND LOCATIONS OF ANY BLOCK-OUTS AS MAY BE REQUIRED FOR BUILDING SERVICES. 5. CONTRACTOR SHALL VERIFY ALL DETAILS, DIMENSIONS, AND SPECIFICATIONS AND NOTIFY DESIGNER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. FRAMING NOTES: 1. PLATE HEIGHT = 8'-1 1/8". 2. UNLESS OTHERWISE NOTED, PROVIDE (1) KINGSTUD AND (1) TRIMMER AT EA. SIDE OF ALL OPENINGS. 3. RAFTER-TO-RAFTER CONNECTIONS PROVIDED BY TRUSS MFR. TRUSS MFR. SHALL VERIFY ALL DIMENSIONS OFF OF FND. PLAN AND FLOOR PLAN PRIOR TO PLANNING. 4. FASTEN ALL RAFTERS TO DOUBLE TOP PLATE W/ H2.5 TIE OR SDWC-15450 SCREWS AS PER TRUSS CALC'S AT EA. END. 5. ROOF SHEATHING - 7/16" APA RATED OSB WITH 8d NAILS AT 6" O.C. ALONG EDGES AND DIAPHRAGM BOUNDARIES AND 12" O.C. IN THE FIELD. 6. PROVIDE ATTIC VENTILATION AS REQ'D BY CODE. DESIGN CRITERIA: 2018 IBC GRAVITY LOADS: SEISMIC LOADS: WIND LOADS: BLD'G ANALYSIS: ROOF SNOW LOAD ROOF DEAD LOAD SOIL SITE CLASS SHORT TERM SPECTRAL RESPONSE, Ss SITE COEFFICIENT, Fa DESIGN SPECTRAL RESPONSE, Sds SEISMIC IMPORTANCE FACTOR SEISMIC DESIGN CATEGORY RESPONSE MODIFICATION COEFFICIENT, R EXPOSURE B BASIC WIND SPEED GUST FACTOR, Kd IMPORTANCE FACTOR OCCUPANCY GROUP CONSTRUCTION TYPE 25 PSF 17 PSF D 0.34 1.52 I 1.0 C 6.5 115 MPH 0.85 1.0 U IV SHEARWALL SCHEDULE MARK SHEATHING 7/16" APA RATED OSB FASTENERS 16 GA. STAPLES EDGE NAILING FIELD NAILING 6" O.C.12" O.C. ANCHOR BOLTS SHEARWALL TAG NOTATIONS 1. SHEATH ENTIRE WALL ABOVE AND BELOW WINDOWS/DOOR AS PER SHEARWALL DESIGNATION. 2. SHEARWALL SHEATHING IS CONTINUOUS BEHIND ADJACENT WALL FRAMING. 1 BLK'G PANEL EDGES. 1/2" DIA. X 10" ANCHOR BOLTS AT 48" O.C. 3:12 ROOF PITCH (TYP.) 1X12 FASCIA W/ 2X10 SUB-FASCIA U.N.O. TYP. 1' - 0"1' - 0"NOTE: FASTEN ROOF JOISTS TO PLATE W/ SIMPSON H2.5A OR SDWC-15450 SCREWS VERIFY3' - 6"1' - 6"1 H1 AT 24" O.C. 2X10 ROOF RAFTERS 2' - 0"6' - 0"2' - 0" 6 (2) 2X4 (2) 2X4 (2) 2X4 (2) 2X4 B1B1B1 B1 7 7 TYP. PLAN NOTES:X 1. OUTLINE OF REMOVABLE ROOF HATCH - VERIFY SIZE / LOCATION W/ CONTRACTOR. 2. PUMP STATION AND WET WELL - VERIFY SIZE AND LOCATION. 3. 4" CONCRETE SLAB W/ 4" COMPACTED GRAVEL BASE - SLOPE SLAB AS REQ'D FOR DRAINAGE INTO WET WELL / DOOR OPENING (SLAB POURED OVER WET WELL WALLS.) 4. STEP STEM WALL DOWN BELOW CONCRETE SLAB (TYP. AT OPENINGS). 5. CONCRETE SLAB OUTLINE - VERIFY SIZE. 6. (2) 2X4 KINGSTUDS W/ (1) 2X4 TRIMMER. 7. SIMPSON IUS1.81/9.5 HANGER - TYP. AT NON-RAFTER "B1" BEAMS. SHEET TITLE: SHEET NUMBER: DRAWN BY: PLOT DATE: PROJECT INFO: MSTR DATE: LOT: BLOCK: GLD JOB #: ALL WORK TO BE COMPLETED BY LICENSED CONTRACTORS USING THE BEST PRACTICES OF TRADE INVOLVED. CONTRACTOR(S) TO VERIFY ALL DIMENSIONS AND CONDITIONS BEFORE PROCEEDING WITH CONSTRUCTION. ALL PLANS, DRAWINGS, AND DESIGNS ARE THE PROPERTY OF GUIDED LIGHT DRAFTING LLC AND SHALL NOT BE REPRODUCED OR COPIED WITHOUT WRITTEN CONSENT BY GUIDED LIGHT DRAFTING LLC. GUIDED LIGHT DRAFTING 5117 WESTON AVE. CALDWELL, ID. 83607 (208) 284-1687 1817 N. LAKES. PLACE #100, MERIDIAN, ID 83646 (208) 939-10457/27/2021 7:02:56 PM CONST. PLANS -IRRIG. PUMP STATION 1.0 RA DELANO SUB. #1 X CMG-210301 X 1/4" = 1'-0" FRONT ELEVATION2 1/4" = 1'-0" RIGHT ELEVATION3 1/4" = 1'-0" REAR ELEVATION4 1/4" = 1'-0" LEFT ELEVATION1 3/4" = 1'-0" TYP. O.H. EAVE5 3/4" = 1'-0" TYP. STEM WALL6 1/4" = 1'-0" FLR./SHEAR/ELEC. PLAN7 1/4" = 1'-0" FOUNDATION PLAN8 BEAM / HEADER SCHEDULE MARK TYPE COMMENTS QTY. B1 (1) 1 3/4" x 9 1/2" LVL ROOF RAFTER/BEAM 4 H1 (2) 2x4 DF #2 B.O. HEADER = T.O. R.O. 1 1/4" = 1'-0" ROOF FRAMING PLAN9 PROJECT DESIGNED FOR: CHALLENGER DEVELOPMENT INC. JDE JOB#: