Loading...
Extended Stay America CZC, DES (A-2021-0153)CERTIFICATE OF ZONING COMPLIANCE REPORT COMMUNITY DEVELOPMENT DEPARTMENT DATE: 9/20/2021 TO: Brandon McDougald — Kimley Horn FROM: Joe Dodson, Associate Planner 208-884-5533 SUBJECT: A-2021-0153 Extended Stay America CZC, DES LOCATION: 3437 E. Pine Avenue I. PROJECT DESCRIPTION ( �/ WE I *-- �AHO Vicinity Map Legend _ It 4 The applicant, Brandon McDougald, requests Certificate of Zoning Compliance (CZC) and Administrative Design Review (DES) approval to construct a new 4-story, 56,000 square foot, hotel with 127 new parking stalls on 2.15 acres of land in the C-G zoning district. II. DECISION The applicant's request for Certificate of Zoning Compliance and Administrative Design Review is approved with the conditions listed in this report. Note: This is not a building permit. Please contact Building Services at (208) 887-2211 to verify if you need a building permit and/or inspection. If you do need a building permit, you must complete that process before you commence the use or construction. Please contact Building Services for additional details about building permits and inspections. Site Specific Conditions of Approval 1. As depicted on the submitted site plan (see Exhibit V.A), cross -access is required to be provided in the southeast corner of the subject property to the parcel to the east (Parcel # R7138490040; 3503 E. Pine Avenue) in perpetuity for future emergency, vehicular, and pedestrian access. 2. All ground -level mechanical equipment must be screened to the height of the unit as viewed from the property line; all rooftop mechanical equipment must be screened as viewed from the farthest edge of the adjoining right-of-way. 3. No signs are approved with this application. Prior to installing any signs on the property, the applicant shall submit a sign permit application consistent with the standards in UDC Chapter 3 Article D and receive approval for such signs. Page 1 4. The applicant shall complete all improvements related to public life, safety, and health as set forth in UDC 11-5C-3B. A surety agreement may be accepted for other improvements in accord with UDC 11-5C-3C. 5. Upon installation of the landscaping and prior to inspection by Planning Division staff, the applicant shall provide a written certificate of completion as set forth in UDC 11-313-14A. 6. The site plan prepared by Kimley Horn & Associates, Inc. on July 26, 2021, labeled Preliminary Site Plan, is approved by the City of Meridian Planning Division as shown in Exhibit A. 7. The site plan prepared by Kimley Horn & Associates, Inc. on July 26, 2021, labeled Preliminary Landscape Plan, is approved by the City of Meridian Planning Division as shown in Exhibit B. 8. The elevations prepared by Woolpert Architects on September 14, 2021, labeled Exterior Elevations, are approved by the City of Meridian Planning Division as shown in Exhibit C. 9. The approved site plan, landscape plan and/or elevations may not be altered without prior written approval of the City of Meridian Planning Division. 10. The applicant shall pay any applicable impact fees prior to the issuance of a building permit. 11. If any changes must be made to the site plan to accommodate ACHD requirements, the applicant shall submit a new site plan to the City of Meridian Planning Division for approval prior to issuance of the building permit. 12. The applicant shall complete all required improvements prior to issuance of a Certificate of Occupancy. It is unlawful to use or occupy any building or structure until the Building Official has issued a Certificate of Occupancy. General Conditions of Approval 1. The applicant and/or assigns shall have the continuing obligation to provide irrigation that meets the standards as set forth in UDC 11-3B-6 and to install and maintain all landscaping as set forth in UDC 11-3B-5, UDC 11-3B-13 and UDC 11-3B-14. 2. The project is subject to all current City of Meridian ordinances and previous conditions of approval associated with this site, including but not limited to: RZ-05-009 & PP-05-026 (Porky Park Subdivision); FP-05-066 (Porky Place No. 1). 3. The issuance of this CZC does not release the applicant from any previous requirements of the other permits issued for the site. 4. The applicant and/or property owner shall have an ongoing obligation to prune all trees to a minimum height of six feet above the ground or sidewalk surface to afford greater visibility of the area. 5. The applicant has a continuing obligation to comply with the outdoor lighting provisions as set forth in UDC 11-3A-11. 6. The applicant and/or property owner shall have an ongoing obligation to maintain all landscaping and constructed features within the clear vision triangle consistent with the standards in UDC 11- 3A-3. 7. The applicant and/or property owner shall have an ongoing obligation to comply with the specific use standards for the proposed hotel use: UDC 11-4-3-23. III. CITY COUNCIL REVIEW The applicant or a party of record may request City Council review of a decision of the Director. All requests for review shall be filed in writing with the Planning Division on or before October 5, 2021, Page 2 within fifteen (15) days after the written decision is issued, and contain the information listed in UDC 11-5A-6B. If City Council review of the decision is not requested, the action of the Director represents a final decision on a land use application. You have the right to request a regulatory taking analysis under Idaho Code 67-8003. IV. EXPIRATION The Certificate of Zoning Compliance shall expire if the construction, alteration or the use has not commenced within one year of the date of issuance of the Certificate of Zoning Compliance. In accord with the above provisions, the subject Certificate of Zoning Compliance is valid until September 20, 2022. Page 3 V. EXHIBITS A. Site Plan (date: 7/26/202 1) 12- i Rd WI)i UJOH0<A91 i �1L Pill W1 LEO z 0 5 1 IN Page 4 II Jr - E R E AVEE. ' ' li I'li FI'SI' 'I I'I i� I I i � .w w�.u..,uy f • L1 J— LSJ�J— 31_. � k o-. . . . I ' �;Fssbc I ' 7, I eT a 11 1j I' I) HNM f STOMM cl� xR I I I A ' 1 MI e n n I I' .l �Iry 14 1 3 li i I 9 —C Page 5 B. Landscape Plan (date: 7/26/2021) _r OLt H"W r �li L � v� � _ a a ��" �m - PRELIMINARY LANDSCAPE PLAN EXTENDED STAY AMERICA Kimley»>Horn Page 6 C. Elevations (9/14/2021) ILLUIdfNATM COLOR! MATERIAL LEGEND —NA-0DP1N3 MATCH sXAPEOE"A VINYL ADJACENT COLOR ACCENT CORNICE. TYP VANDOW—� STUCCO: PPG 1025-1 "COMMERCIAL WHITE" Tro PAFAPETP �L - STUCCO_ PPG 1025-3 "WHISKERS' PILASTERS r s PMarA -I �i - STUCCO: PPG 1025-4"SHARKSKIN" WALL-MOUNTEP LIGHT _ - STUCCO: PPG 14-13"OYSTER SHELL" FIXTURE-TYPICALiSTB LEVEL Hr - STUCCO. PPG 1021-G'CURLENl HORIZONTAL wnrraDL 6 - ICEYPLAN EXTERIOR TRIM: CP410"BRONZETONE" HORZONTAL FLAT � .3v - KINGSIZE DOVE GRAY BRICK BY ACME BRICK ElFs coawce Y _ ,RD FLE-TYPICAL iSrB A 3reo FLooR NHERE sIaWN _ LEVELS AIAIMINUM LOWER 3.2C- FOR AT LEAST 30'A OF APPLICABLE DOORS FRAME FREFABALU.INUMCANOPY FAGADF5 USE ANY OOMBI NOTION OF CONCRETE. MASONRY, STONE, OR UNIQUE WITH HANGER ROCC VARIATION OF COLOR TEXTURE, OR SIDE ELEVATION MATERIAL AT LEAST 1C-INCHES IN XEIOXT, AROUND THE BASE OF TX E BVIL 11 2 wALLHX0—D LIGHT FINDER- TYPICAL IST& SRN. SHAPED EIFS� FI%EDVINYL � ILUMINATED VERT ILALLONTROLJOIM ��� PFEFINISMEO METAL HORIZONTAL FLAT EIF6 CORNICE FLODRNNEFESFIfYMI ACCENT CORN CE\ IN J 1 �SGNAGE _ T COP NG TO MATCH TYP �CONTROLJDINT (O PARAPEF FLA.sERs \ -IT. RITE JncENT COLaR �TRuss BEARmG rr�i-•, STAY CA . -3 LEVEL t — PREFAB ALUMINUM CANOPY HORIZONTAL FLAT PREFAB ALUMINUM CANOPY ILL UMINATEDBIGNAGE WITH HANGER RODS EIFSCORNICE NTNI HANOER RODS O10-FORAT LEAST OF APPLICABLE WALL -MOUNTED LIGHT FACADES USE AR COMBINATION OF 5T S3R0L ALUMINUM SLIDING ENTRPNCEJ CONOR ETF. MASON RY. sroNF, Op uNIQUS FLOOR NAIEFE SHOWN 3.3E-FENESTRATIO NALTERXATIV E:INCORPORATEDOORSAHD DOORS MAR EA 'IADN OF LULOR10TEM�E,NH NIXDOVJS FOR AT LEAST90X OF APPLICABLE FIRST FLOOR BUILDING FACE. 2865 st - I L FACADE, ORSVOO£STTM]R NlCLUS10N VSlNO FA UX TREAiR1ENT5 GWZING: 3S5g AROUND TXE BASE OF TXE BUILDING,IGx THAT INCORPoRATEAT LEAST TWO OFTHEFOLLDWiN6:MATERIAL I TRELLIS 1BBtl CHANGE$ I'II REPEALS IN CONJUNCTION WITH CDLOR OR RfVfAL5l COLO0.. 3B2 d MATERIAL CHANGE, QUALIFYING MODULATION SUCH AE RELE85E0 f 1 iaa5 si-3f 9% AREAS,R]ARCHITECTU RILL TRELUs. ANTIINGS ANOISI CANCERS FRONT ELEVATION OVER ACC E88A0.EA6, DETACHE➢STRUCTURES SUCH AS PERDOLh OR 81MILAR ARCHITECTJRAL FEATURESAND DETAILS I I ^RREAF MERIDIAN HOLDINGS EXTENDED STAY AMERICA Page 7 \A.II W O OELNP E A T September 14. 2021 COLOR/ MATERIAL LEGEND SHAPED EIFS uuMlNAreo— wlwrL wlnoc;;—FREFINISHEO METAL ILL IAGE COPING TO MATCH ACJACENT COLOR, TVP STUCCO. PPG 1025-1 "COMMERCIAL WHITE" "WHISKERS' ACCENTCORNICE PILASTERS I Tro PARAPET 1 r STUCCO: PPG 10253 STUCCO', PPG 1025.4"SHARKSKIN" WALL LIGHT is - STUCCO'. PPG 14-13"OYSTER SHELL" -MOUNTED F3ixrua E-rrPlcaL V LEVEL RD FLOOR VAIERE 910VAi - STUCCO. PPG 1021-6'CURLEW HOR¢ONTALCONTRCL e - EXTERIOR TRIM'. CP410 "BRONZETONE" - KINGSIZE DOVE GRAY BRICK BY ACME BRICK PLHT Daw lUlg D WITH HANGER ROCS ALUMINUM wwER LEVEL3'p PY - _ KEYPLAN BUILDING FACE'. 610N GLAZING 23 TRELLIS: 108 �T WALL -MOUNTED LIGHTS -1VRICAL,STS _ _ _ LEVEL3 _ 3RU3RDF FLOOR VAIERE 310VN NO R IZONTAL FLAT LEVELI ---- EIFS CORNICE - 3o%0FAPrtUURLE VOOR& M FACADES USE ANY COMBINATION OF HAMF i CC NCRETE, MASONRY, STONEOR UNIOUE 3.9E-FENESTRATION ALTERNATNM INCORPOPATEDCCRSAND VARIATIONOF COLOR.TEXTURE OR 1 WINDOWS FORAT LEAST 3C%OF APPLICABLE MATERIAL, AT LEAST IOJNLHfSINHEIGH T, l FACADE OR SVOCEST iNE1R INC1U5lOH AROUND THE BASE O F TH E BUILDING Il TH TnvcowvoaaiF AitFASTTwo of CHANGES, III REVEALS IN CONJUNCTION MATERIAL CHANGE. DUALIFVING MODULATION SIDE ELEVATION AREAS,12IARCHITECTURALTRELU3AWNINGSANDI3ICANOMEB OVE R ACCESS AREAS, BETSCHED STRUCTU FIRST FLOOR USING FAYXTRE9_EN. ilfEwuornxc.- TERiuL W1TH COLOR ORMA SUCH AS RECESSED RES SUCH AS _ PERGOLA, OR SIMILAR ARCHITECTURAL FEATURESAND DETAILS WALL -MOUNTED LIGHT FIXTURE FIXEDVIN FLOORVNIEREEHOVUJ WINDOW SHAPED EIFS—. VERTICALOONTROL HORIZONTAL CONTROL ACC QJT CORNICE JOINT JOINT ILUMINATED ))��PREFINI5HE0 METAL �SIGN— -�COPINGTO MATCH FLAT EIFscoHNIL� ADJACENT COLOR,TYP Tl0 PARAPET _ _ PILASTERS rac CHICLE n�� - LEVELS ,LEVELS BE BE _ _ _ _ _BE b LEVELS $LEVELI T LPNOPY lMTH HANGER i EIFSCOR111 RODS WALL-MOUNT1 LIC11T HXrDHE-rYPicAL,sTa aRD AwIIINUM L"'I" HOLLOW 1-1-00—H.PME A W MINUM VJINOO Wf: PREFAB ALUMINUM LANOPV ALUMINUM VOOR WrtTI HANGER RODS "REAR ELEVATION LE 9,20 FOR AT LEAST ]O%` T""OF. FACADES USE A" COMBINATION OF CONCRETE. MASONRY. STONE OR RXICUE ArLEA.�;BTN�HESNHH , M GH FLOOR VNIERE EHONM UHAT, AROUNB THE BASE OF THE BUILgNO MERIDIAN RREAF HOLDINGS EXTENDED STAY A M E R I C A s e D Tembe r 14. 2021 Page 8