ElevationsFIXTURE
ORANGE LIGHT
LX-1
EP-1
EP-1
EP-3
19'-2" AFF
T.O. PARAPET
21'-10" AFF
T.O. PARAPET
EP-1
EP-4
20'-6" AFF.
T.O. PARAPET
TO BE PAINTED
EIFS
SIGNAGE TO BE
BE PAINTED
CORNICE TO
EP-1
EP-1
EP-1
FLAT CANOPY
EP-6
THIN BRICK
EB-1
SIDING
VERTICAL WOOD PANEL
PAINTED
1" EIFS BAND TO BE
EQ.EQ.
FIXTURE
ORANGE LIGHT
EB-1
ASSEMBLY
STOREFRONT
EIFS TO BE PAINTED
TO BE PAINTED
EIFS ACCENT BAND
THIN BRICK VENEER
CANOPY
EP-6
ORANGE FINISH
MANUFACTURER IN
PURCHASED FROM
DOORS ARE TO BE
THIN BRICK
EB-1
EF-1EP-3 EP-3
LX-1
S-1 S-2
3"3"LX-1 EQ.EQ.EP-1
EP-1
EP-2 (BROWN)2'-9 1/2 "8"EB-1
Rear Elevation
Scale: 1/4" = 1'-0"
Front Elevation
Scale: 1/4" = 1'-0"
A3.0
Exterior Elevations
POPEYES
C
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
B
A
C
D
E
F
G
H
I
J
K
L
M
N
O
B
C
D
E
F
G
H
I
J
K
L
M
N
O
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Mark Description Date
Building Design & Documentation 2021-2022 Jeffrey Parker Architects Inc.
04/15/21
03/11/21
FOR SITE PLAN APPROVAL
Building for:
MERIDIAN, ID
SPECIFICATIONS:
PROTECTION
DIVISION 7: THERMAL AND MOISTURE
SECTION 7C: SHEET METAL WORK
PROVISION
GENERAL
DOWNSPOUTS, AND GUTTERS.
1. SCOPE: FURNISH AND INSTALL GRAVEL STOPS, FLASHING, PARAPET CAP,
7B: MEMBRANE ROOFING.
A. ROOFING MEMBRANE FLASHING IS INCLUDED IN SECTION
MATERIALS
1. MATERIALS SHEET METAL: .032 ALUMINUM.
CONCEALED ONLY.
ALUMINUM ROOFING NAILS MAY BE USED FOR FASTENERS INTO WOOD WHEN
2. NAIL FASTENERS: 1 3/4" X 11 GAUGE GALVANIZED, STAINLESS STEEL, OR
3. WASHERS: NEOPRENE
SEALING WASHER FOR EXPOSED FASTENING.
MINIMUM INTO WOOD OR 1/2" MINIMUM INTO STEEL. PROVIDE NEOPRENE
SCREW, 1/4" MINIMUM DIAMETER WITH SUFFICIENT LENGTH TO PENETRATE 1"
4. SCREW FASTENERS: CORROSION-RESISTANT, SELF-TAPPING, HEX HEAD
PERFORMANCE
ADJACENT MATERIALS. VERIFY WITH POPEYES' CONSTRUCTION MANAGER.
1. INSTALLATION: EXPOSED FLASHINGS SHALL BE PAINTED TO MATCH
DIVISION 9: FINISHES
SECTION 9G: EIFS
PART 1 GENERAL
1.01 DESCRIPTION
CODE REQUIREMENTS.
ALLOWABLE DEFLECTION CRITERIA AND APPLICABLE BUILDING
TO WHICH THE EIFS IS ATTACHED SHALL MEET L/240 MAXIMUM
A. DESIGN REQUIREMENTS: THE STRUCTURAL WALL SYSTEM
1.02 SUBMITTALS
A. SUBMIT SAMPLES FOR APPROVAL AS DIRECTED BY OWNER.
HANDLING
1.03 DELIVERY, STORAGE AND
HAZARD, AND SAFETY DATA.
APPLICATION INSTRUCTIONS AND APPROPRIATE HEALTH,
NAME AND IDENTIFICATION OF PRODUCT WITH WRITTEN
ORIGINAL SEALED CONTAINERS BEARING MANUFACTURER'S
A. ALL EIFS MATERIALS SHALL BE DELIVERED IN THEIR
THE GROUND AND PROTECTED FROM MOISTURE.
PROPORTIONED BAGGED MATERIALS SHALL BE STORED OFF
FROM EXTREME HEAT, SUN AND FROST. FACTORY
B. ALL EIFS READY-MIXED MATERIALS SHALL BE PROTECTED
1.04 JOB CONDITIONS
UNTIL DRY.
BE PROTECTED FROM EXPOSURE TO RAIN AND FREEZING
SHALL BE PROVIDED. THE INSTALLED EIFS MATERIALS SHALL
IN TEMPERATURES LESS THAN 40° F SUPPLEMENTARY HEAT
DURING APPLICATION AND DRYING PERIOD. FOR INSTALLATION
AND SURFACE TEMPERATURES CANNOT BE KEPT ABOVE 40° F
A. ALL EIFS MATERIALS SHALL NEVER BE APPLIED IF AMBIENT
MANUFACTURER'S INSTRUCTIONS.
REQUIREMENTS, THE EIFS INSTALLATION MAY BEGIN PER
CORRECTION OF ANY DEVIATIONS FROM SPECIFICATION
C. AFTER SATISFACTORY INSPECTION OF SURFACES AND
MATERIAL A MINIMUM OF 1/4" TO FORM AN ISOLATION JOINT.
HAVE THE INSULATION BOARD CUT BACK FROM THE ADJOINING
TERMINATES (FOR EXAMPLE, WINDOW AND DOOR FRAMES) SHALL
ALL AREAS WHERE THE EIFS MEETS DISSIMILAR MATERIAL OR
DETAILS (EXAMPLE-WINDOW AND DOOR HEADS AND JAMBS).
FOLLOWED AT ALL EXPOSED BOARD EDGES IN ACCORDANCE WITH
SURFACE OF THE BOARD. THIS "BACKWRAP" PROCEDURE SHALL BE
BOARD EDGE AND COVER APPROXIMATELY 4" ON THE OUTSIDE
ADHERE 4" OF MESH ONTO THE WALL, BE ABLE TO WRAP AROUND THE
D. THE STARTER STRIP OF MESH SHALL BE WIDE ENOUGH TO
WITH SLIVERS OF INSULATION OR AN APPROVED SPRAY FOAM.
ALL OPEN JOINTS IN THE INSULATION BOARD LAYER SHALL BE FILLED
ANY ADHESIVE FROM GETTING BETWEEN THE JOINTS OF THE BOARDS.
THERMAL BREAKS IN THE EIFS. CARE MUST BE TAKEN TO PREVENT
JOINTS SHALL BE BUTTED TIGHTLY TOGETHER TO ELIMINATE ANY
SHALL BRIDGE SHEATHING JOINTS BY A MINIMUM OF 8". ALL BOARD
SURFACE OF THE BOARDS TO INSURE UNIFORM CONTACT. BOARDS
AND OUTSIDE CORNERS. APPLY FIRM PRESSURE OVER ENTIRE
STAGGER VERTICAL JOINTS AND INTERLOCK BOARDS AT ALL INSIDE
E. APPLY THE ADHESIVE TO THE BACK OF THE INSULATION BOARD.
MECHANICAL FASTENER SHALL NOT BE USED.
F. NAILS, SCREWS, OR ANY OTHER TYPE OF NONTHERMAL
WATER FORM GETTING INTO OR BEHIND THE SYSTEM.
INSTALLED AFTER GROUND COAT IS FULLY DRY TO PREVENT ANY
PROCEDURE. APPROPRIATE SEALANT/PRIMER AND BACKER SHALL BE
AND MESH IN ACCORDANCE WITH STANDARD "BACKWRAPPING"
BOARD EDGES SHALL BE COATED WITH APPROPRIATE GROUND COAT
JOINT TO PROVIDE APPROPRIATE JOINT SIZE (SEE DETAILS) AND ALL
CONSTRUCTION. THE EIFS SHALL TERMINATE AT THE EXPANSION
CONSTRUCTION, AND AT FLOOR LINES IN MULTILEVEL WOOD FRAME
EXIST IN THE SUBSTRATE, WHERE THE EIFS ADJOINS DISSIMILAR
G. EXPANSION JOINTS ARE REQUIRED IN THE EIFS WHERE THEY
FORBIDDEN.
H. USE OF PLASTIC OR METAL CORNER BEADS, STOPBEADS, ETC., IS
THOROUGHLY DRY BEFORE APPLYING PRIMER OR FINISH.
SUCH THAT THE MESH IS FULLY EMBEDDED. ALLOW GROUND COAT TO
IN THE MESH. THE FINISH THICKNESS OF THE GROUND COAT SHALL BE
OVERLAPPED NOT LESS THAN 2-1/2" AT MESH JOINTS.AVOID WRINKLES
THE MESH SHALL BE DOUBLE WRAPPED AT ALL CORNERS AND
EMBED STANDARD REINFORCING MESH INTO THE WET GROUND COAT.
HORIZONTALLY OR VERTICALLY IN STRIPS OF 40", AND IMMEDIATELY
A UNIFORM THICKNESS OF APPROXIMATELY 1/16". WORK
WITH PROPER SPRAY EQUIPMENT OR A STAINLESS STEEL TROWEL TO
I. APPLY APPROPRIATE GROUND COAT OVER THE INSULATION BOARD
STO PRIMER (OPTIONAL) OR STO FINISH.
IMPACT RESISTANCE. ALLOW TO DRY BEFORE APPLICATION OF EITHER
STANDARD MESH CREATING SECOND MESH LAYER AND ADDITIONAL
J. DUPLICATE INSTALLATION PROCESS NOTED IN 3.01 M USING
GENERAL RULES FOR APPLICATION OF FINISHES ARE AS FOLLOWS:
WITH A STAINLESS STEEL TROWEL, DEPENDING ON FINISH SPECIFIED.
FINISH SHALL BE APPLIED BY SPRAYING, ROLLING OR TROWELING
AFTER THE GROUND COAT/PRIMER HAS THOROUGHLY DRIED. THE
DIRECTLY OVER THE GROUND COAT (OR PRIMED GROUND COAT) ONLY
DRY THOROUGHLY BEFORE APPLYING FINISH. P. APPLY FINISH
SPRAY EQUIPMENT OVER CLEAN, DRY GROUND COAT AND ALLOW TO
K. IF A PRIMER IS USED, APPLY WITH BRUSH, ROLLER OR PROPER
WORKABILITY).
(SMALL AMOUNTS OF CLEAN WATER MAY BE ADDED TO AID
THOROUGHLY STIR THE FINISH TO A UNIFORM CONSISTENCY
1. USE A CLEAN, RUST-FREE, HIGH-SPEED MIXER TO
2. AVOID APPLICATION IN DIRECT SUNLIGHT.
WORKING TO A WET EDGE.
3. APPLY FINISH IN A CONTINUOUS APPLICATION, ALWAYS
AGAINST WIND, DUST, DIRT, RAIN AND FREEZING.
DRYING AND MAY REQUIRE ADDED MEASURES OF PROTECTION
OR DAMP CONDITIONS EXTEND WORKING TIME AND RETARD
SCHEDULING OF WORK TO ACHIEVE DESIRED RESULTS; COOL
ACCELERATE DRYING AND MAY REQUIRE ADJUSTMENTS IN THE
TIME. HOT OR DRY CONDITIONS LIMIT WORKING TIME AND
4. WEATHER CONDITIONS AFFECT APPLICATION AND DRYING
LEFT AFTER ANY GROOVES ARE CUT).
SYSTEM. (A MINIMUM OF 3/4" INSULATION BOARD MUST BE
5. AESTHETIC "U"-GROOVES MAY BE DESIGNED INTO THE
PLASTIC TROWEL TO ACHIEVE THEIR RILLED TEXTURE.
6. "R" (RILLED TEXTURE) FINISHES MUST BE FLOATED WITH A
SIDE.
7. AVOID INSTALLING SEPARATE BATCHES OF FINISH SIDE-BY-
COLOR TO MATCH EXTERIOR FINISH SCHEDULE COLORS.
8 . APPLY FINISH COLOR TO EIFS MIX AND APPLY TO WALL.
SYSTEM SPECIFICATIONS AT ALL OTHER LOCATIONS.
RESISTANCE, USING INTERMEDIATE MESH. USE THE STANDARD
IMPACT SYSTEM ADJACENT TO DOORS FOR ADDITIONAL IMPACT
L. EXTERIOR INSULATION AND FINISH TEXTURE SYSTEM: APPLY HIGH
MATERIAL WARRANTY.
A. PROVIDE MANUFACTURERE'S STANDARD LABOR AND
1.11 WARRANTY
PART 2 PRODUCTS
2.01 MANUFACTURERS
A. DRYVIT SYSTEMS, INC.
2.02 ADHESIVES
BASED ADHESIVE.
A. DISPERSION ADHESIVE - NONCEMENTITIOUS, ACRYLIC
INSULATION BOARD.
SPECIFICATION FOR EXPANDED POLYSTYRENE (EPS)
ASTM C 578 TYPE I REQUIREMENTS, AND EIMA GUIDELINE
POLYSTYRENE (EPS) INSULATION BOARD IN COMPLIANCE WITH
A. NOMINAL 1.0 lb/cubic feet (16 kg/cubic meter) EXPANDED
2.03 INSULATION BOARD
2.04 BASECOAT
PORTLAND CEMENT CONTENT BY WEIGHT.
BASE COAT WITH FIBER REINFORCEMENT AND LESS THAN 33%
A. ONE-COMPONENT POLYMER MODIFIED CEMENTITIOUS
2.05 REINFORCING MESHES
DRYVIT MATERIALS.
ALKALINE RESISTANT COATING FOR COMPATIBILITY WITH
FABRIC MADE WITH MINIMUM 25 PERCENT BY WEIGHT
SYMMETRICAL, INTERLACED OPEN-WEAVE GLASS FIBER
1. MESH - NOMINAL 4.5 oz/sq.yd. (163 g/sq.meter),
A. STANDARD MESH
COMPATIBILITY WITH DRYVIT MATERIALS.
FABRIC WITH ALKALINE RESISTANT COATING FOR
HIGH IMPACT, INTERWOVEN, OPEN WEAVE GLASS FIBER
1. INTERMEDIATE MESH (MESH C) - NOMINAL 11.0 oz/sq.yd.
B. HIGH IMPACT MESH
2.06 PRIMER
ACRYLIC BASED PRIMER (FOR ACRYLIC BASED FINISHES)
A. PRIMER
B. WATER: CLEAN AND POTABLE.
2.08 JOB MIXED INGREDIENTS
A. PORTLAND CEMENT: ASTM C 150, TYPE I.
FORMULAS FOR FINISH COLOR.
A. ACRYLIC BASED TEXTURED WALL COATING. SEE E.I.F.S.
2.07 FINISH COAT
PRIOR TO INSTALLATION OF THE EIFS.
SHALL BE CORRECTED PER MANUFACT. RECOMMENDATIONS
OTHER CONTAMINANT. ANY SURFACES NOT IN COMPLIANCE
MILDEW, FUNGUS, LATENCY, PAINT, EFFLORESCENCE AND ANY
PROPERLY CURED AND FREE OF DIRT, DUST, OIL, GREASE,
2. CONCRETE, MASONRY OR PLASTER SURFACES SHALL BE
THE EIFS.
SPECIFICATION REQUIREMENTS PRIOR TO INSTALLATION OF
NOT IN COMPLIANCE SHALL BE REPLACED TO CONFORM WITH
HANDLING, INSTALLATION AND PROTECTION. ANY SHEATHING
SHALL BE FOLLOWED FOR STORAGE, HANDLING, STORAGE,
PUBLISHED RECOMMENDATIONS SHALL BE FOLLOWED FOR
STORAGE, HANDLING AND INSTALLATION. MANUFACTURER'S
CONSTRUCTION GUIDELINES SHALL BE FOLLOWED FOR
EXPOSURE 1 CLASSIFICATION. APA DESIGN AND
PLYWOOD ASSOCIATION) REQUIREMENTS FOR EXTERIOR OR
1. PLYWOOD SHEATHING SHALL MEET A.P.A. (AMERICAN
PRIOR TO INSTALLATION OF THE EIFS:
INSPECTED FOR COMPLIANCE WITH THE FOLLOWING REQUIREMENTS
IRREGULARITIES GREATER THAN 1/8" in 4'-0". SURFACES SHALL BE
DAMAGE FROM MOISTURE. SURFACES SHALL BE UNIFORM, WITH NO
SOUND, CLEAN, DRY AND FREE OF WARPAGE, RESIDUAL MOISTURE OR
B. THE SURFACE TO RECEIVE THE EIFS SHALL BE STRUCTURALLY
ACCELERATORS, RAPID BINDERS, ETC., ARE FORBIDDEN.
OF CLEAN WATER AS DIRECTED ON LABEL. ANTIFREEZE,
ALTERED BY ADDING ANY ADDITIVES, EXCEPT FOR SMALL AMOUNTS
A. UNDER NO CIRCUMSTANCES SHALL ANY OF THE PRODUCTS BE
PART 3 EXECUTION
Outsulation LCMD option1 as manuf by Dryvit
TYP. EIFS DETAIL
NTS
(SYSTEM 1)
DRAINAGE MAT
DRYVIT FINISH
BASE COAT DRYVIT GENESIS
FASTENER
WITH CORROSION RESISTANT
DRYVIT APPROVED WASHER
BASE COAT ®DRYVIT GENESIS
EPS INSULATION BOARD
DRYVIT REINFORCING MESH
DRYVIT DRAINAGE MAT
BY OTHERS
RESISTIVE BARRIER,
CODE APPROVED WATER
SUBSTRATE
FRAMING
A9
3
A8
2
SPECIFICATIONS
FOR SIGN MANUFACTURERS AND
REFER TO MASTER FINISH SCHEDULE
FOR SHUTTER MANUFACTURERS
REFER TO MASTER FINISH SCHEDULE
FOR EXTERIOR FINISHES
REFER TO MASTER FINISH SCHEDULE
FIXTURE SPECIFICATIONS
SCHEDULE FOR EXTERIOR LIGHT
REFER TO MASTER LIGHT FIXTURE
LX-1
PAINTED
EIFS TO BE
PAINTED
DOOR TO BE
PAINTED
CANOPY TO BE
BE PAINTED
CORNICE TO PAINTED
CORNICE TO BE
LEADER
GUTTER AND
BE PAINTED
GAS METER TO
EP-1
EP-2
EP-5
EP-1
PT-2
EB-1
THIN BRICK
VENEER
THIN BRICK
EB-1
EP-1
20'-6" AFF
T.O. PARAPET
21'-10" AFF
T.O. PARAPET
9'-4" AFF
CANOPYB.O.
6'-2" AFF
T.O. WINDOW
0'-0" AFF.
FINISHED FLOOR
8'-0" AFF.
T.O. WALL
EP-3
EP-2
19'-2" AFF
T.O. PARAPET
EIFS TO BE PAINTED
WALL WITH EIFS FINISH
COOLER TO HAVE FRAMED
EP-2
EF-3 3"3"PAINTED
TO BE
CORNICE
EP-2
FIXTURE
ORANGE LIGHT
THIN BRICK
PROVIDE NEW
0'-0" AFF.
FINISHED FLOOR
9'-4" AFF.
B.O. AWNING
PAINTED
CANOPY TO BE
EP-5
FIXTURE
ORANGE LIGHT
EP-1