Elevations1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 L_ 0 N M L K J H G F E D C B SPECIFICATIONS: DIVISION 7: THERMALAND MOISTURE PROTECTION GENERAL SECTION 7C: SHEET METALWORK PROVISION 1. SCOPE: FURNISH AND INSTALL GRAVEL STOPS, FLASHING, PARAPET CAP, DOWNSPOUTS, AND GUTTERS. A. ROOFING MEMBRANE FLASHING IS INCLUDED IN SECTION 7B: MEMBRANE ROOFING. MATERIALS 1. MATERIALS SHEET METAL: .032 ALUMINUM. 2. NAIL FASTENERS: 1 3/4" X 11 GAUGE GALVANIZED, STAINLESS STEEL, OR ALUMINUM ROOFING NAILS MAY BE USED FOR FASTENERS INTO WOOD WHEN CONCEALED ONLY. 3. WASHERS: NEOPRENE 4. SCREW FASTENERS: CORROSION -RESISTANT, SELF -TAPPING, HEX HEAD SCREW, 1/4" MINIMUM DIAMETER WITH SUFFICIENT LENGTH TO PENETRATE 1" MINIMUM INTO WOOD OR 1/2" MINIMUM INTO STEEL. PROVIDE NEOPRENE SEALING WASHER FOR EXPOSED FASTENING. PERFORMANCE 1. INSTALLATION: EXPOSED FLASHINGS SHALL BE PAINTED TO MATCH ADJACENT MATERIALS. VERIFY WITH POPEYES' CONSTRUCTION MANAGER. DIVISION 9: FINISHES SECTION 9G: EIFS PART 1 GENERAL 1.01 DESCRIPTION A. DESIGN REQUIREMENTS: THE STRUCTURAL WALL SYSTEM TO WHICH THE EIFS IS ATTACHED SHALL MEET U240 MAXIMUM ALLOWABLE DEFLECTION CRITERIAAND APPLICABLE BUILDING CODE REQUIREMENTS. 1.02 SUBMITTALS A. SUBMIT SAMPLES FOR APPROVAL AS DIRECTED BY OWNER. 1.03 DELIVERY, STORAGE AND HANDLING A. ALL EIFS MATERIALS SHALL BE DELIVERED IN THEIR ORIGINAL SEALED CONTAINERS BEARING MANUFACTURER'S NAME AND IDENTIFICATION OF PRODUCT WITH WRITTEN APPLICATION INSTRUCTIONS AND APPROPRIATE HEALTH, HAZARD, AND SAFETY DATA. B. ALL EIFS READY -MIXED MATERIALS SHALL BE PROTECTED FROM EXTREME HEAT, SUN AND FROST. FACTORY PROPORTIONED BAGGED MATERIALS SHALL BE STORED OFF THE GROUND AND PROTECTED FROM MOISTURE. 1.04 JOB CONDITIONS A. ALL EIFS MATERIALS SHALL NEVER BE APPLIED IF AMBIENT AND SURFACE TEMPERATURES CANNOT BE KEPT ABOVE 40" F DURING APPLICATION AND DRYING PERIOD. FOR INSTALLATION IN TEMPERATURES LESS THAN 40° F SUPPLEMENTARY HEAT SHALL BE PROVIDED. THE INSTALLED EIFS MATERIALS SHALL BE PROTECTED FROM EXPOSURE TO RAIN AND FREEZING UNTIL DRY. 1.11 WARRANTY A. PROVIDE MAN U FACTU RERE'S STANDARD LABOR AND MATERIAL WARRANTY. PART 2 PRODUCTS 2.01 MANUFACTURERS A. DRYVIT SYSTEMS, INC. 2.02 ADHESIVES A. DISPERSION ADHESIVE - NONCEMENTITIOUS, ACRYLIC BASED ADHESIVE. 2.03 INSULATION BOARD A. NOMINAL 1.0 Ib/cubic feet (16 kg/cubic meter) EXPANDED POLYSTYRENE (EPS) INSULATION BOARD IN COMPLIANCE WITH ASTM C 578 TYPE I REQUIREMENTS, AND EIMA GUIDELINE SPECIFICATION FOR EXPANDED POLYSTYRENE (EPS) INSULATION BOARD. 2.04 BASECOAT A. ONE -COMPONENT POLYMER MODIFIED CEMENTITIOUS BASE COAT WITH FIBER REINFORCEMENT AND LESS THAN 33% PORTLAND CEMENT CONTENT BY WEIGHT. 2.05 REINFORCING MESHES A. STANDARD MESH 1. MESH -NOMINAL 4.5 oz/sq.yd. (163 g/sq.meter), SYMMETRICAL, INTERLACED OPEN -WEAVE GLASS FIBER FABRIC MADE WITH MINIMUM 25 PERCENT BY WEIGHT ALKALINE RESISTANT COATING FOR COMPATIBILITY WITH DRYVIT MATERIALS. B. HIGH IMPACT MESH 1. INTERMEDIATE MESH (MESH C) - NOMINAL 11.0 oz/sq.yd. HIGH IMPACT, INTERWOVEN, OPEN WEAVE GLASS FIBER FABRIC WITH ALKALINE RESISTANT COATING FOR COMPATIBILITY WITH DRYVIT MATERIALS. 2.06 PRIMER A. PRIMER ACRYLIC BASED PRIMER (FORACRYLIC BASED FINISHES) 2.07 FINISH COAT A. ACRYLIC BASED TEXTURED WALL COATING. SEE E.I.F.S. FORMULAS FOR FINISH COLOR. 2.08 JOB MIXED INGREDIENTS A. PORTLAND CEMENT: ASTM C 150, TYPE I. B. WATER: CLEAN AND POTABLE. PART 3 EXECUTION A. UNDER NO CIRCUMSTANCES SHALL ANY OF THE PRODUCTS BE ALTERED BY ADDING ANY ADDITIVES, EXCEPT FOR SMALL AMOUNTS OF CLEAN WATERAS DIRECTED ON LABEL. ANTIFREEZE, ACCELERATORS, RAPID BINDERS, ETC., ARE FORBIDDEN. B. THE SURFACE TO RECEIVE THE EIFS SHALL BE STRUCTURALLY SOUND, CLEAN, DRYAND FREE OF WARPAGE, RESIDUAL MOISTURE OR DAMAGE FROM MOISTURE. SURFACES SHALL BE UNIFORM, WITH NO IRREGULARITIES GREATER THAN 1/8" in 4'-0". SURFACES SHALL BE INSPECTED FOR COMPLIANCE WITH THE FOLLOWING REQUIREMENTS PRIOR TO INSTALLATION OF THE EIFS: 1. PLYWOOD SHEATHING SHALL MEET A.P.A. (AMERICAN PLYWOOD ASSOCIATION) REQUIREMENTS FOR EXTERIOR OR EXPOSURE 1 CLASSIFICATION. APA DESIGN AND CONSTRUCTION GUIDELINES SHALL BE FOLLOWED FOR STORAGE, HANDLING AND INSTALLATION. MANUFACTURER'S PUBLISHED RECOMMENDATIONS SHALL BE FOLLOWED FOR SHALL BE FOLLOWED FOR STORAGE, HANDLING, STORAGE, HANDLING, INSTALLATION AND PROTECTION. ANY SHEATHING NOT IN COMPLIANCE SHALL BE REPLACED TO CONFORM WITH SPECIFICATION REQUIREMENTS PRIOR TO INSTALLATION OF THE EIFS. 2. CONCRETE, MASONRY OR PLASTER SURFACES SHALL BE PROPERLY CURED AND FREE OF DIRT, DUST, OIL, GREASE, MILDEW, FUNGUS, LATENCY, PAINT, EFFLORESCENCE AND ANY OTHER CONTAMINANT. ANY SURFACES NOT IN COMPLIANCE SHALL BE CORRECTED PER MANUFACT. RECOMMENDATIONS PRIOR TO INSTALLATION OF THE EIFS. C. AFTER SATISFACTORY INSPECTION OF SURFACES AND CORRECTION OF ANY DEVIATIONS FROM SPECIFICATION REQUIREMENTS, THE EIFS INSTALLATION MAY BEGIN PER MANUFACTURER'S INSTRUCTIONS. D. THE STARTER STRIP OF MESH SHALL BE WIDE ENOUGH TO ADHERE 4" OF MESH ONTO THE WALL, BE ABLE TO WRAPAROUND THE BOARD EDGE AND COVER APPROXIMATELY 4" ON THE OUTSIDE SURFACE OF THE BOARD. THIS "BACKWRAP" PROCEDURE SHALL BE FOLLOWED AT ALL EXPOSED BOARD EDGES IN ACCORDANCE WITH DETAILS (EXAMPLE -WINDOW AND DOOR HEADS AND JAMBS). ALL AREAS WHERE THE EIFS MEETS DISSIMILAR MATERIAL OR TERMINATES (FOR EXAMPLE, WINDOW AND DOOR FRAMES) SHALL HAVE THE INSULATION BOARD CUT BACK FROM THE ADJOINING MATERIAL MINIMUM OF 1/4" TO FORM AN ISOLATION JOINT. E. APPLY THE ADHESIVE TO THE BACK OF THE INSULATION BOARD. STAGGER VERTICAL JOINTS AND INTERLOCK BOARDS AT ALL INSIDE AND OUTSIDE CORNERS. APPLY FIRM PRESSURE OVER ENTIRE SURFACE OF THE BOARDS TO INSURE UNIFORM CONTACT. BOARDS SHALL BRIDGE SHEATHING JOINTS BYA MINIMUM OF 8". ALL BOARD JOINTS SHALL BE BUTTED TIGHTLY TOGETHER TO ELIMINATE ANY THERMAL BREAKS IN THE EIFS. CARE MUST BE TAKEN TO PREVENT ANYADHESIVE FROM GETTING BETWEEN THE JOINTS OF THE BOARDS. ALL OPEN JOINTS IN THE INSULATION BOARD LAYER SHALL BE FILLED WITH SLIVERS OF INSULATION OR AN APPROVED SPRAY FOAM. F. NAILS, SCREWS, OR ANY OTHER TYPE OF NONTHERMAL MECHANICAL FASTENER SHALL NOT BE USED. G. EXPANSION JOINTS ARE REQUIRED IN THE EIFS WHERE THEY EXIST IN THE SUBSTRATE, WHERE THE EIFS ADJOINS DISSIMILAR CONSTRUCTION, AND AT FLOOR LINES IN MULTILEVEL WOOD FRAME CONSTRUCTION. THE EIFS SHALL TERMINATE AT THE EXPANSION JOINT TO PROVIDE APPROPRIATE JOINT SIZE (SEE DETAILS) AND ALL BOARD EDGES SHALL BE COATED WITH APPROPRIATE GROUND COAT AND MESH IN ACCORDANCE WITH STANDARD "BACKWRAPPING" PROCEDURE. APPROPRIATE SEALANT/PRIMER AND BACKER SHALL BE INSTALLED AFTER GROUND COAT IS FULLY DRY TO PREVENT ANY WATER FORM GETTING INTO OR BEHIND THE SYSTEM. H. USE OF PLASTIC OR METAL CORNER BEADS, STOPBEADS, ETC., IS FORBIDDEN. I. APPLY APPROPRIATE GROUND COAT OVER THE INSULATION BOARD WITH PROPER SPRAY EQUIPMENT ORA STAINLESS STEEL TROWEL TO A UNIFORM THICKNESS OF APPROXIMATELY 1/16". WORK HORIZONTALLY OR VERTICALLY IN STRIPS OF 40", AND IMMEDIATELY EMBED STANDARD REINFORCING MESH INTO THE WET GROUND COAT. THE MESH SHALL BE DOUBLE WRAPPED ATALL CORNERS AND OVERLAPPED NOT LESS THAN 2-1/2" AT MESH JOINTS.AVOID WRINKLES IN THE MESH. THE FINISH THICKNESS OF THE GROUND COAT SHALL BE SUCH THAT THE MESH IS FULLY EMBEDDED. ALLOW GROUND COAT TO THOROUGHLY DRY BEFORE APPLYING PRIMER OR FINISH. J. DUPLICATE INSTALLATION PROCESS NOTED IN 3.01 M USING STANDARD MESH CREATING SECOND MESH LAYER AND ADDITIONAL IMPACT RESISTANCE. ALLOW TO DRY BEFORE APPLICATION OF EITHER STO PRIMER (OPTIONAL) OR STO FINISH. K. IF A PRIMER IS USED, APPLY WITH BRUSH, ROLLER OR PROPER SPRAY EQUIPMENT OVER CLEAN, DRY GROUND COAT AND ALLOW TO DRY THOROUGHLY BEFORE APPLYING FINISH. P. APPLY FINISH DIRECTLY OVER THE GROUND COAT (OR PRIMED GROUND COAT) ONLY AFTER THE GROUND COAT/PRIMER HAS THOROUGHLY DRIED. THE FINISH SHALL BE APPLIED BY SPRAYING, ROLLING OR TROWELING WITH A STAINLESS STEEL TROWEL, DEPENDING ON FINISH SPECIFIED. GENERAL RULES FOR APPLICATION OF FINISHES ARE AS FOLLOWS: 1. USE A CLEAN, RUST -FREE, HIGH-SPEED MIXER TO THOROUGHLY STIR THE FINISH TO A UNIFORM CONSISTENCY (SMALL AMOUNTS OF CLEAN WATER MAYBE ADDED TO AID WORKABILITY). 2. AVOID APPLICATION INDIRECT SUNLIGHT. 3. APPLY FINISH IN A CONTINUOUS APPLICATION, ALWAYS WORKING TO A WET EDGE. 4. WEATHER CONDITIONS AFFECT APPLICATION AND DRYING TIME. HOT OR DRY CONDITIONS LIMIT WORKING TIME AND ACCELERATE DRYING AND MAY REQUIRE ADJUSTMENTS IN THE SCHEDULING OF WORK TO ACHIEVE DESIRED RESULTS; COOL OR DAMP CONDITIONS EXTEND WORKING TIME AND RETARD DRYING AND MAY REQUIRE ADDED MEASURES OF PROTECTION AGAINST WIND, DUST, DIRT, RAIN AND FREEZING. 5. AESTHETIC "U"-GROOVES MAYBE DESIGNED INTO THE SYSTEM. (A MINIMUM OF 3/4" INSULATION BOARD MUST BE LEFT AFTER ANY GROOVES ARE CUT). 6. "W (RILLED TEXTURE) FINISHES MUST BE FLOATED WITH A PLASTIC TROWEL TO ACHIEVE THEIR RILLED TEXTURE. 7. AVOID INSTALLING SEPARATE BATCHES OF FINISH SIDE -BY - SIDE. 8. APPLY FINISH COLOR TO EIFS MIX AND APPLY TO WALL. COLOR TO MATCH EXTERIOR FINISH SCHEDULE COLORS. L. EXTERIOR INSULATION AND FINISH TEXTURE SYSTEM: APPLY HIGH IMPACT SYSTEM ADJACENT TO DOORS FOR ADDITIONAL IMPACT RESISTANCE, USING INTERMEDIATE MESH. USE THE STANDARD SYSTEM SPECIFICATIONS ATALL OTHER LOCATIONS. CORNICE TO BE EIFS TO BE PAINTED PAINTED EP-1 CORNICE TO EP-1 EP-1 BE PAINTED GUTTER AND LEADER T.O. PARAPET EP-2 21'-10" AFF EP-1 2 T.O. PARAPET AS 20'-6" AFF T.O. PARAPET 19'-2" AFF M I I � � ORANGE LIGHT ORANGE LIGH { FIXTURE LX-1 FIXTURE LX-1 THIN BRICK EB-1 ❑ ❑ CANOPY TO BE PAINTED E B.O. CANOPY 9'-4" AFF T.O. WALL V-0" AFF. T.O. WINDOW 6-2" AFF THIN nn�TF n VENEER ICK Rear Elevation Scale: 1/4'' = 1'-0" REFER TO MASTER FINISH SCHEDULE FOR SIGN MANUFACTURERS AND SPECIFICATIONS ■ 11111101 FRAMING SUBSTRATE CODE APPROVED WATER RESISTIVE BARRIER, BY OTHERS ° N ° DRYVIT APPROVED WASHER WITH CORROSION RESISTANT FASTENER DRYVIT DRAINAGE MAT EPS INSULATION BOARD DRYVIT GENESIS@ BASE COAT DRYVIT REINFORCING MESH L DRYVIT GENESIS BASE COAT DRYVIT FINISH DRAINAGE MAT (SYSTEM 1) Outsulation LCMD option1 as manuf by Dryvit TYP. EIFS DETAIL NITS k REFER TO MASTER FINISH SCHEDULE FOR SHUTTER MANUFACTURERS REFER TO MASTER FINISH SCHEDULE FOR EXTERIOR FINISHES REFER TO MASTER LIGHT FIXTURE SCHEDULE FOR EXTERIOR LIGHT FIXTURE SPECIFICATIONS 2021 POPEYE'S FINISH SCHEDULE EXTERIOR MATERIALS & FINISH SCHEDULE "TO BE USED WITH FS-LEGACY (1846) 03.07.21 CODE MATERIAL LOCATION SOURCE PRODUCT COLOR DIMENSION ADDITIONAL INFORMATION 7 3/8" x 2 1/2" x NICHIHA FIBER VINTAGE BRICK ALEXANDRIA BUFF 3/4" CONTACT: MATT STEPHENSON M: CEMENT 770.789.8228 popeyes@nichiha.com EB-1 FACE BRICK ACCENT TOWER BRICK ALTERNATE OPTION: 8-1/8"x2-1/16"x CONTACT: CREATIVE ALTERNATEOPTION: THINBRICK FLAGSTAFF 5/8" popeyestile@creatiwmaterialscorp.com MATERIALS 1.800.207.2967 Ed 7797 CORPORATION FRONT FACADE NICHIHA FIBER 17-7/8" H x 119- CONTACT: MATT STEPHENSON M: EF-1 EXTERIOR WOOD SIDING EXTERIOR WALLS CEMENT VINTAGE WOOD AWP 3030 CEDAR 5/16" L 770.789.8228 popeyes@nichiha.com MAIN WALL SURFACE CONTACT: RODGER LIPPMAN C: EP-1 EXTERIOR PAINT ABOVE WAINSCOT BENJAMIN ULTRA SPEC 500 EGGSHELL WHITE OCA 25 MOONLIGHT WH TE 848.702.0239 ACCENT TRIM MOORE rodger.lippman@benjaminmoom.com CONTACT: RODGER LIPPMAN C: EP-2 EXTERIOR PAINT BRICK TOWER METAL BENJAMIN ROOT BEER CANDY 2105-20 848.702.0239 COPING MOORE rodger.lippman@benjam inmoore.com EXTERIOR WAINSCOT, BENJAMIN CONTACT: RODGER LIPPMAN C: EP-3 EXTERIOR PAINT SLL PAINT, AND MOORS ULTRA SPEC 500 EGGSHELL Y" "GRAHC-170 STONINGTON GREY 848.702.0239 DUMSPTER WALLS rodger.lippman@benjaminmoore.com BOLLARDS, PYLON POLE CONTACT: RODGER LIPPMAN C: EP-4 EXTERIOR PAINT AND DIRECTIONAL SIGN BENJAMIN SAFETY YELLOW 848.702.0239 POLES MOORS rodger.lippman@benjaminmoore.com DRIVE THRU WINDOW PROVIDED BY ORANGE. PANTONE #3564 C. EP-5 METAL/PAINT CANOPY MANUFACTURER PROVIDED BY MANUFACTURER PROVIDED BY MANUFACTURER PROVIDED BY MANUFACTURER PROVIDED BY TEAL. PANTONE #326 C. PROVIDED EP-6 METAL/PAINT BUILDING CANOPIES MANUFACTURER PROVIDED BY MANUFACTURER BY MANUFACTURER PROVIDED BY MANUFACTURER CONTACT: RODGER LIPPMAN C: EP-7 EXTERIOR PAINT DUMSPTER GATES BENJAMIN FACTORY FINISH BLACK 848.702.0239 MOORE rod g e r. l i p p m a n@ be n j a m i n m oo re. co m CONTACT: RODGER LIPPMAN C: EP-8 EXTERIOR PAINT ALL EXTERIOR WALLS BENJAMIN ALIPHATIC ACRYLICC URETHANE- GLOSS ANTI-GRAFFITTI COAT 848.702,0239 MOORE V500-00 rodger.lippman@benjaminmoore.com BE TOED EXTERIOR DOORS MAIN PROVIDED BY PURCHASED FROM ORANGE. PANTONE #3564 C. DP-1 DOOR ENTRANCE AND SIDE MANUFACTURER MANUFACTURER IN PROVIDED BY MANUFACTURER ENTRANCE ORANGE FINISH TO BE PROVIDED BY PURCHASED FROM TEAL. PANTONE #326 C. PROVIDED ES-1 SHUTTERS EXTERIOR WALLS MANUFACTURER MANUFACTURER IN BY MANUFACTURER PROVIDED BY MANUFACTURER TEAL FINISH ■= F Mark Description Date FOR SITE PLAN APPROVAL 04/15/21 E Building Design & Documentation ©2021-2022 Jeffrey Parker Architects Inc. ,In jeffre Y Parker architects ARCHITECTURE PLANNING ENGINEERING 855 28th Street SE Grand Rapids MI 49508 Building for: Phone: 616-241-0090 Fax: 616-241- 0098 POPEYES rtC MERIDIAN, ID E Exterior Elevations Issued Drawing No. 03/11/21 Project No. A300 A 2 3 4 5 i 7 I i 10 12 13 14 15