Loading...
Elevation (1)1 2 3 4 5 6 7 8 9 CORNICE TO BE PAINTED EP-2 CORNICE TO ORANGE LIGHT EIFS TO BE PAINTED EP 1AINTED �FIXTURE EP 1rillOO6ApARApET 0 N M L T.O. WALL 8,_0„ Al EQ . EQ EQ i D.T. WINDOW ju "5 A10 K COOLER TO HAVE FRAMED t1. EIFS TO BE EIFS ACCENT SHUTTERS EIFS SHUTTER THIN BRICK EB-1 CANOPY EP-5 EF-3 WALL WITH EIFS FINISH PAINTED EP-3 BAND LIGHT GREYED SURROUND PAINTED EP-1 DT Side Elevation 10 11 EIFS TO BE ORANGE LIGHT PAINTED FIXTURE 1" EIFS BAND TO BE PAINTED EP 1 12 13 CORNICE CORNICE TO BE TO BE PAINTED EP-1 PAINTED —AIEW EP-1 SIGNAGE - REFER TO SIGNAGE PACKAGE T.O. PARAPET 21'-10" AFF IIIIll 7 1 i RAILING TO BE PAINTED EP-2 EIFS ACCENT BAND TO BE PAINTED EP-3 19'-2" AFF ORANGE LIGHT FIXTURE UC 1 NEW SIGNAGE - REFER TO SIGNAGE PACKAGE CANOPY EP-6 9'-4" AFF NEW VERTICAL WOOD PANEL SIDING EF-1 FINISHED FLOOR AL 0'-0" Al 8'-0" Al VERTICAL WOO tlr5 AUUl 1 1" EIFS TO BE Eo-5 I U BE J L)UUKS AKE I U BE J I HIV tlKIURJ tlr5 I U BE PANEL SIDING EF-1 BAND TO BE PAINTED EP-3 PAINTED EP_1 PURCHASED FROM VENEER EB-1 PAINTED EP-1 SHUTTERS 1" EIFS TO BE EIFS TRIM TO BE PAINTED EP-3 PAINTED GAS METER COOLER TO HAVE FRAMED WALL WITH EIFS FINISH EP-3 PAINTED EP 3 MANUFACTURER IN EP-1 ORANGE FINISH Entry Side Elevation F Scale: 1/4" = 1'-0" SPECIFICATIONS SECTION TITLE 2.5. DEFLECTION: MAXIMUM ALLOWABLE DEFLECTION IN ANY MEMBER QUALITYASSURANCE ALUMINUM - FRAMED ENTRANCES AND STOREFRONTS YKKAP PRODUCT WHEN TESTED IN ACCORDANCE WITH ASTM E 330 WITH 1. QUALIFICATIONS: 3. SHIM AND BRACE ALUMINUM SYSTEM BEFORE ANCHORING TO SERIES YKKAP YES 45 FS/FI SERIES ALLOWABLE STRESS IN ACCORDANCE WITH AA SPECIFICATIONS FOR 1.1. INSTALLER QUALIFICATIONS: INSTALLER EXPERIENCED (AS STRUCTURE. PART 1 GENERAL ALUMINUM STRUCTURES. DETERMINED BY CONTRACTOR) TO PERFORM WORK OF THIS 4. PROVIDE SILL FLASHING AT EXTERIOR STOREFRONT SYSTEMS. EXTEND 1. SECTION INCLUDES: ALUMINUM STOREFRONT, INCLUDING: 2.6. THERMAL MOVEMENT: PROVIDE FOR THERMAL MOVEMENT CAUSED SECTION WHO HAS SPECIALIZED IN THE INSTALLATION OF WORK EXTRUDED FLASHING CONTINUOUS WITH SPLICE JOINTS; SET IN E 1.1. YKKAP SERIES YES 45 FI STOREFRONT SYSTEM (INSULATING BY 180 DEGREES F. (82.2 DEGREES C.) SURFACE SIMILAR TO THAT REQUIRED FOR THIS PROJECT. IF REQUESTED BY CONTINUOUS BEADS OF SEALANT. GLAZING) TEMPERATURE, WITHOUT CAUSING BUCKLING STRESSES ON GLASS, OWNER, SUBMIT REFERENCE LIST OF COMPLETED PROJECTS. 5. VERIFY STOREFRONT SYSTEM ALLOWS WATER ENTERING SYSTEM TO BE 1. RELATED SECTIONS: JOINT SEAL FAILURE, UNDUE STRESS ON STRUCTURAL ELEMENTS, 2.2. PRE -INSTALLATION MEETINGS: CONDUCT PRE -INSTALLATION COLLECTED IN GUTTERS AND WEPT TO EXTERIOR. VERIFY METAL JOINTS 1.1. SINGLE SOURCE REQUIREMENT: ALL PRODUCTS LISTED BELOW DAMAGING LOADS ON FASTENERS, REDUCTION OF PERFORMANCE, MEETING TO VERIFY PROJECT REQUIREMENTS, SUBSTRATE ARE SEALED IN ACCORDANCE WITH MANUFACTURERS INSTALLATION SHALL BE BY THE SAME MANUFACTURER. OR DETRIMENTAL EFFECTS. CONDITIONS, MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND INSTRUCTIONS. 2.7. THERMAL PERFORMANCE: WHEN TESTED IN ACCORDANCE WITH MANUFACTURER'S WARRANTY REQUIREMENTS. SECTION 8D: GLAZING 2. SYSTEM PERFORMANCE DESCRIPTION AAMA 1503.1 AND NFRC 100: 3. PROJECT CONDITIONS / SITE CONDITIONS. 2.1. PERFORMANCE REQUIREMENTS: PROVIDEALUMINUM 2.7.1. CONDENSATION RESISTANCE FACTOR (CRF F ): A MINIMUM OF 44 FOR 3.1. FIELD MEASUREMENTS: VERIFYACTUAL MEASUREMENTS / GENERAL PROVISIONS STOREFRONT SYSTEMS THAT COMPLY WITH PERFORMANCE YES 45 FI SYSTEMS. OPENINGS BY FIELD MEASUREMENTS BEFORE FABRICATION; RETAIN 1. SCOPE: FURNISH AND INSTALL GLASS IN STOREFRONT AND DRIVE-THRU REQUIREMENTS INDICATED, AS DEMONSTRATED BY TESTING 2.7.2. THERMAL TRANSMITTANCE U VALUE: 0.51 BTU/HR/FT'/"F OR LESS FOR RECORDED MEASUREMENTS ON SHOP DRAWINGS. COORDINATE D MANUFACTURER'S ASSEMBLIES IN ACCORDANCE WITH TEST YES 45 FI SYSTEMS. FIELD MEASUREMENTS, FABRICATION SCHEDULE WITH SERVICE WINDOW. METHOD INDICATED. NOTE: THERMAL PERFORMANCE FOR THE GLAZED SYSTEM AS A WHOLE CONSTRUCTION PROGRESS TO AVOID CONSTRUCTION DELAYS. MATERIALS 2.2. AIR INFILTRATION: WHEN TESTED IN ACCORDANCE WITH ASTM E WILL BE AFFECTED BY THE CHARACTERISTICS OF THE GLASS 4. WARRANTY 283 AT DIFFERENTIAL STATIC PRESSURE OF 6.24 PSF (299 PA), SPECIFIED. 4.1. PROJECT WARRANTY: REFER TO "CONDITIONS OF THE CONTRACT' 1. TYPE: SOLAR CONTROL LOW-E CLEAR INSULATING GLASS COMPLETED STOREFRONT SYSTEMS SHALL HAVE MAXIMUM SUBMITTALS FOR PROJECT WARRANTY PROVISIONS. "SOLARBAN 60 (2) CLEAR + CLEAR BY VITRO ARCHITECTURAL GLASS. ALLOWABLE INFILTRATION OF: 2.1. GENERAL: PREPARE, REVIEW, APPROVE, AND SUBMIT SPECIFIED 4.2. MANUFACTURER'S WARRANTY: SUBMIT, FOR OWNER'S ACCEPTANCE, 1.1. OUTDOOR LITE: CLEAR GLASS, SPUTTER COATED ON SECOND 2.2.1. 0.06 Cl (1.10 M - /H • M-) FOR YES 45 FI SYSTEMS. SUBMITTALS IN ACCORDANCE WITH "CONDITIONS OF THE CONTRACT' MANUFACTURER'S STANDARD WARRANTY DOCUMENT EXECUTED BY SURFACE (2) 2.3. WATER INFILTRATION: NO UNCONTROLLED WATER WHEN TESTED AND DIVISION 1 SUBMITTALS SECTIONS. PRODUCT DATA, SHOP AN AUTHORIZED COMPANY OFFICIAL. 1.2. INDOOR LITE: CLEAR (TRANSPARENT) FLOAT GLASS. IN ACCORDANCE WITH ASTM E 331 AT TEST PRESSURE DRAWINGS, SAMPLES, AND SIMILAR SUBMITTALS ARE DEFINED IN 4.3. WARRANT( PERIOD: MANUFACTURER'S ONE (1) YEAR STANDARD 1.3. LOW-E COATING: "SOLARBAW 60 SOLAR CONTROL (SPUTTERED) BY DIFFERENTIAL OF: "CONDITIONS OF THE CONTRACT." WARRANTY COMMENCING ON THE SUBSTANTIAL DATE OF VITRO ARCHITECTURAL GLASS 0 2.3.1. 10 PSF (479 PA) FOR YES 45 FI SYSTEMS. (OR WHEN REQUIRED, 2.2. PRODUCT DATA: SUBMIT PRODUCT DATA FOR EACH TYPE COMPLETION FOR THE PROJECT PROVIDED THAT THE WARRANTY, IN LOCATION: SECOND SURFACE (2) FIELD TESTED IN ACCORDANCE WITH AAMA 503). FASTENER STOREFRONT SERIES SPECIFIED AS REQUIRED BY THE ARCHITECT OF NO EVENT, SHALL START LATER THAN SIX (6) MONTHS FROM THE HEADS MUST BE SEATED AND SEALED AGAINST SILL RECORD. DATE OF SHIPMENT BY YKK AP AMERICA INC. EDITOR NOTE: LONGER 2• PERFORMANCE VALUES: FLASHING ON ANY FASTENERS THAT PENETRATE THROUGH 2.3. SUBSTITUTIONS: WHENEVER SUBSTITUTE PRODUCTS ARE TO BE WARRANTY PERIODS ARE AVAILABLE ATADDITIONAL COST. 2.1. VISIBLE LIGHT TRANSMITTANCE: 70% THE SILL FLASHING. CONSIDERED, SUPPORTING TECHNICAL DATA, SAMPLES, AND TEST 5. PART 2 PRODUCTS 2.2. U-VALUE WINTER: 0.29 2.4. WIND LOADS: COMPLETED STOREFRONT SYSTEM SHALL REPORTS MUST BE SUBMITTED TEN (10) WORKING DAYS PRIOR TO BID 5.1. MANUFACTURERS (ACCEPTABLE MANUFACTURERS/PRODUCTS) 2.3. U-VALUE SUMMER: 0.27 WITHSTAND WIND PRESSURE LOADS NORMAL TO WALL PLANE DATE IN ORDER TO MAKE AVALID COMPARISON. 5.2. ACCEPTABLE MANUFACTURERS: YKKAP AMERICA INC. 2.4. SHGC: 0.39 INDICATED: 2.4. SHOP DRAWINGS: PROVIDE TO THE ARCHITECT OF RECORD IF 5.3. STOREFRONT SYSTEM: YKKAP YES 45 FI STOREFRONT SYSTEM. 2.5. SHADING COEFFICIENT: 0.45 2.4.1. EXTERIOR WALLS: REQUESTED. SHOP DRAWINGS SHOWING LAYOUT, PROFILES, AND 6. COLORS: AS SPECIFIED BY POPEYES LOUISIANA KITCHEN: 2.6. OUTDOOR VISIBLE LIGHT REFLECTANCE: 11 % 6 2.4.1.1. POSITIVE PRESSURE: PER LOCAL CODE. PRODUCT COMPONENTS, INCLUDING ANCHORAGE, ACCESSORIES, 2.4.1.2. NEGATIVE PRESSURE: PER LOCAL CODE. FINISH COLORS AND TEXTURES. INSTALLATION APPROVED MANUFACTURERS: 2.4.1.3. INTERIOR WALLS (PRESSURE ACTING IN EITHER 2.5. QUALITY ASSURANCE / CONTROL SUBMITTALS: 1. GENERAL: INSTALL MANUFACTURER'S SYSTEM IN ACCORDANCE WITH VITRO CERTIFIED FABRICATOR REQUIRED DIRECTION): PER LOCAL CODE. 2.5.1. TEST REPORTS: SUBMIT CERTIFIED TEST REPORTS SHOWING SHOP DRAWINGS, AND WITHIN SPECIFIED TOLERANCES. CERTIFICATION: BOTH LITES TO BE CRADLE TO CRADLE CERTIFIEDTM' MINIMUM 2.5. DEFLECTION: MAXIMUM ALLOWABLE DEFLECTION IN ANY MEMBER COMPLIANCE WITH SPECIFIED PERFORMANCE CHARACTERISTICS 1. PROTECTALUMINUM MEMBERS IN CONTACT WITH MASONRY, STEEL, BRONZE LEVEL, BY CRADLE TO CRADLE PRODUCT INNOVATION INSTITUTE WHEN TESTED IN ACCORDANCE WITH ASTM E 330 WITH AND PHYSICAL PROPERTIES IF REQUIRED BY THE LOCAL PERMITTING CONCRETE, OR DISSIMILAR MATERIALS USING NYLON PADS WWW.C2CCERTIFIED.ORG). ALLOWABLE STRESS IN ACCORDANCE WITH AA SPECIFICATIONS AUTHORITY. OR BITUMINOUS COATING. FORALUMINUM STRUCTURES. 2.6. CLOSEOUT SUBMITTALS: 2. SHIM AND BRACE ALUMINUM SYSTEM BEFORE ANCHORING TO OUTDOOR APPEARANCE: CLEAR 2.6.1. WARRANTY: SUBMIT WARRANTY DOCUMENTS SPECIFIED HEREIN. STRUCTURE. INSULATING UNIT CONSTRUCTION: 1/4" (6MM) GLASS + 1/2" (13MM) AIR SPACE + 1/4" (6MM) GLASS A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 DRIVE THRU SPECIFICATIONS DRIVE THRU WINDOW - QUIKSERV MODEL # BP-7241 E - STANDARD INSTALLATION MODEL # BP-7241 E-IP - HIGH WIND ZONE AS DETERMINED BY THE LOCAL BUILDING CODE GENERAL NOTES: ACTUAL DIMENSIONS: 72" (W) x 27" (H) ROUGH OPENING 72 1/2" (W) x 41 112" (H) 1) EYE SET TO BE MOUNTED DIRECTLY BELOW THE SERVICE OPENIN BAR TO BE MOUNTED ON THE WALL. 2) ANCHOR SCREWS TO BE SUPPLIED BY THE CONTRACTOR. 3) JUNCTION BOX TO BE SUPPLIED BY CONTRACTOR. INSTALLATION: 1) QUIKSERV WINDOWS MUST BE INSTALLED LEVEL AND SQUARE TO I FORK PROPERLY. 2) ANCHOR ACCORDING TO THE LOCAL BUILDING CODE ANCHOR SCHEDULE. 3) 115V/15 AMP. DEDICATED CIRCUIT FEATURE. 4) RECOMMENDED HEIGHT FROM FLOOR TO SERVCE OPENING TO BE 6". (CHECK FOR ANY LOCAL CODES OR CITY CODES) 5) SILICONE ALL EXTERIOR AND INTERIOR JOINTS. 6) ALL OTHER TYPES OF ANCHORING TO BE APPROVED BY CERTIFIED ENGINEER. 14 61 (2) DOUBLE LOUVER VINYL SHUTTER 1" SPACE GAP EIFS FRAME, PAINTED EP-1 15 ' Mark Description 4/Date ' FOR SITE PLAN APPROVAL 015/21 Building Design & Documentation 2022 Jeffrey Parker Architects Jeffrey Parker architects ARCHITECTURE PLANNING ENGINEERING 855 28thStreet SE Phone: 616-241-OD90 Grand Rapios MI 49508 Fax: 616-241-OD98 Building for. POPEYES MERIDIAN, ID Exterior Elevations Issued Drawing No. 03/11/21 Project No. All M L K J E 11