Loading...
Application MaterialsApplicant name:JACKSON CLEVERLEY Phone: Applicant address: 2775 W NAVIGATOR DRIVE SUITE 220, MERIDIAN, ID 83642 Email:jackson@bvadev.com Owner name:BRAD MILLER, ADLER AB OWNER 1, LLC Phone:Fax: Owner address: 8666 W EMERALD ST SUITE 200, BOISE, ID 83704 Email: Administrative Applicant Information Type of Review Requested File number:A-2021-0122 Assigned Planner:Joseph Dodson Related Files: Subject Property Information Location/street address:2640 E LANARK ST Assessor's parcel number(s):R6510590050 Township, range, section:3N1E8 Agent name (e.g. architect, engineer, developer, representative):JACKSON CLEVERLEY Firm name:Phone:Fax: Address:2775 W NAVIGATOR DRIVE SUITE 220 Email:jackson@bvadev.com Contact name:Phone:Fax: Contact address:Email: Project/Application Name:Advanced Heating and Cooling - DES, CZC Description of Work:Approximately a 17,500 square foot building on just under 2 acres with a yard, warehouse and distribution center Project Description Planning Division ADMINISTRATIVE APPLICATION 33 E Broadway Avenue, Suite 102ƔMeridian, Idaho 83642 Phone: (208)884-5533ƔFacsimile: (208) 888-6854ƔWebsite: www.meridaincity.org 1 APPLICATION TYPES Is this application exempt from fees?:No Certificate of Zoning Compliance - CZC:CHECKED Does project have prior approval?:No Does your project contain new construction and/or modifications to an existing building or the site?: Yes Design Review - DES:CHECKED ADDRESS VERIFICATION Address Verification Permit Number:LDAV-2021-0408 TYPE OF USE PROPOSED Office:CHECKED Industrial:CHECKED PUBLIC WORKS INFRASTRUCTURE Does this project require the extension of public infrastructure?:No PROPERTY INFORMATION General Location:Northwest of Eagle and Franklin intersection Current Land Use:Vacant Total Acreage:1.96 Prior Approvals (File Numbers):Ord. 731 (Olsen & Bush No. 2, 1996) ZONING DISTRICT(S) I-L:CHECKED PROJECT INFORMATION Site Plan Date (MM/DD/YYYY):6/30/2021 Landscape Plan Date (MM/DD/YYYY):6/25/2021 Elevations Date (MM/DD/YYYY):6/28/2021 Percentage of Site Devoted to Building:20.9 Percentage of Site Devoted to Landscaping:15.1 Percentage of Site Devoted to Paving:64 Who will own and Maintain the Pressurized Irrigation System in this Development:Advanced Heating and Cooling Irrigation District:Nampa Meridian Primary Irrigation Source:PI System Secondary Irrigation Source:City Water Square Footage of Landscaped Areas to be Irrigated by City Water Connection:0 Proposed Building Height:30' Number of Standard Parking Spaces Provided:47 Number of Compact Parking Spaces Provided:0 In Reclaimed Water Buffer:No Application Information 33 E Broadway Avenue, Suite 102ƔMeridian, Idaho 83642 Phone: (208)884-5533ƔFacsimile: (208) 888-6854ƔWebsite: www.meridaincity.org 2 TIME EXTENSION INFORMATION Number of months extension:24 APPLICATION DISCLAIMER I have read and accept the above terms:CHECKED Your signature:Jackson Cleverley 33 E Broadway Avenue, Suite 102ƔMeridian, Idaho 83642 Phone: (208)884-5533ƔFacsimile: (208) 888-6854ƔWebsite: www.meridaincity.org 3 BVA Development 2775 Navigator Dr. Suite 220 Meridian, ID 83642 June 25, 2021 City of Meridian Attn: Planning Department 33 East Broadway Avenue Meridian, Idaho 83642 Re: Design Review Narrative – Advanced Heating and Cooling Building Dear Planning Staff: Thank you for the opportunity to submit our proposal for Advanced Heating and Cooling. The proposed building will be located on E. Lanark Street blending with the surrounding commercial uses. The building is a two story approximately 20,300 sf building that contains warehouse space for distribution of products and office, conference rooms to support the business. The building is articulated with different colors of metal panels that reflect the massing of the building. The southern and east elevations predominantly visible from the street have two different colors of metal panels that breaks up the elevation and provides an accent for the 2-story office building that has storefront windows to provide good wayfinding for guests. The norther and west elevations are for the warehouse area of the building and doors and warehouse roll-up doors for ease of access for distribution of products. Mechanical systems will be internal to the building and not be visible on the exterior. The roof will be a slopped metal that will blend with the metal wall panels. The trash enclosure is a concrete masonry unit structure, and the enclosure is on the southwest side of the building outside of the secure gate. Thank you for the consideration and we look forward to your approval of our proposal. Please contact our office if you have any further questions. Sincerely, Jared Schmidt Architect BVA Development swstvwetoetoetoetoetoetoetoetoetoetoetoetoetoetoetoetoetoetoetoetoeTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPtoetoetoetoetoetoetoe toetoetoetoetoetoetoetoetoetoetoetoetoetoetoetoetoetoetoeTOPTOPTOPTOPTOPTOPTOPTOPTO P TO PtoetoetoetoetoetoetoetoetoetoetoetoetoetoeTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPtoetoetoetoetoetoetoetoetoetoetoetoe25' LANDSCAPE BUFFERALONG RESIDENTIAL10' LANDSCAPE BUFFERALONG LOCAL ROAD8'82'25'28'37'29.1'19'9'TYP.17' TYP. 19.1' 90'14.6'89.1' 35.7' 88.5' 87.4'176.5'29'28'312.9'E LANARK STZONED R1ZONED ILZONED ILZONED ILADVANCED HEATING AND COOLING19'TYP.9' TYP.27.7'R50'R15'R3 0 '69'10' PUID EASEMENT60' EVANS DRAINEASEMENT40' SNYDER LATERALEASEMENT54'25'25'54'32.8'22.1' 7'7'77'53.9'57'89.5'STORM WATERSEEPAGE BED 1STORM WATERSEEPAGE BED 2OIL AND SANDINTERCEPTORTYP.OIL AND SANDINTERCEPTORTYP.CATCH BASINTYP.CATCH BASINTYP.2" SERVICE CONNECTIONAND METER6" FIRE LINE CONNECTION4" SEWER LINE CONNECTIONFIRE HYDRANTCONNECT TO EXISTINGWATER MAINCONNECT TO EXISTINGSEWER MAINFENCETYP.EXISTING IRRIGATION STRUCTURETYP.FENCETYP.ADA STALLAND RAMPTYP.EXISTING FIRE HYDRANTEXISTING IRRIGATION STRUCTURETYP.PROPERTY LINETYP.EXISTING POWER POLEEXISTING POWER POLEPROPERTY LINETYP.PROPERTY LINETYP.PROPERTY LINETYP.20' ACHD STORMDRAIN EASMENT20' MERIDIANSEWER EASEMENTHEAVY DUTY ASPHALTTYP.HEAVY DUTYASPHALTTYP.HEAVY DUTY ASPHALTTYP.LIGHT DUTYASPHALTTYP.LIGHT DUTYASPHALTTYP.TRASH ENCLOSURESEE DETAILONE (1) BICYCLE RACKTWO (2) BICYCLE STALLSBENCH020'40'PLAN SCALE: 1" = 20'ADVANCED HEATING AND COOLINGDATE: 06.30.2021DESIGNED: HEHE012640 E LANARK ST, MERIDIAN, IDAHO 83642SITE PLANBALL VENTURES AHLQUIST208.616.1050WWW.BVADEV.COMNSITE INFORMATION:PARCEL R6510590050LOT: 1.96 ACRES (85,567 SF)LOD: 1.96 ACRES (85,567 SF)ZONE INFORMATIONZONE: IL (LIGHT INDUSTRIAL)SETBACKS FROM ROW:·FRONT: 0'·REAR: 0'·INTERIOR SIDE: 0'·STREET: 35'LANDSCAPE BUFFERS:·LOCAL ROAD: 10'·RESIDENTIAL: 25'·NON RESIDENTIAL: 0'BUILDING INFORMATION:TOTAL BUILDING FOOTPRINT: 17,518 SFTOTAL BUILDING AREA: 20,320 SFMAX BUILDING HEIGHT: 30'MAXIMUM ALLOWABLE HEIGHT: 50'PARKING INFORMATION:PARKING STALLS:·41 STALLS REQUIRED·47 STALLS PROVIDEDADA STALLS:·2 ADA STALLS REQUIRED·2 ADA STALLS PROVIDED··1 VAN PARKING ONLYBICYCLE STALLS:·2 STALLS REQUIRED·2 STALLS PROVIDEDNOTE: DIMENSIONS ARE TO BACK OFCURB UNLESS OTHERWISE NOTED.DEVELOPER:BALL VENTURES AHLQUIST2775 W NAVIGATOR DR.MERIDIAN, ID 83642CONTACT:JACKSON CLEVERLEY(208) 616 - 1050ENGINEER:BALL VENTURES AHLQUIST2775 W NAVIGATOR DR.MERIDIAN, ID 83642CONTACT:HALLIE HART(208) 761 - 7191DESIGN REVIEW AND CZCNOTES:1. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.2. ALL DIMENSIONS ARE CONSIDERED TRUE AND REFLECT MANUFACTURER'S SPECIFICATIONS.BOLT PATTERNFRONT ELEVATIONMAKE/MODEL: ANOVA BRS2 SURFACE MOUNT BIKE RACK OR APPROVED EQUAL.COLOR: STAINLESS STEEL REMAINS CLEAN AND RUST FREE WITHOUT PAINT OR ALTERNATIVE FINISHFINISH: 316/316L STAINLESS STEEL IS HIGHLY RESISTANT TO SALT CORROSION, RUSTING, PITTING, AND CRACKING.MATERIAL: 2.38" O.D. SCHEDULE 10, 316/316L STAINLESS STEEL PIPE SUPPORT SECTIONS.LEGS: 7.75" X 5.5" PLATE WITH THREE .5" DIAMETER HOLE PER PLATE FOR SURFACE MOUNTINGBICYCLES: 24.25"4.00".25"32.25"Ø 35.88"Ø.50"BIKE RACK24"EDGE OF CONCRETELANDSCAPE/BUILDINGPLAN VIEW3/8"x3" STAINLESS STEELCONCRETE ANCHOR BOLTAND WASHER (TYP. OF 6)0.3'0.8'0.9'1.2'0.9'0.8'4.5'2.2'0.1'CONC. APRON1/4"/FT. SLOPE MIN.6 YRD DUMPSTEROR BIN2"x2"x1/4" TUBE STEELGATE FRAME W/ 1-1/2"CORRUGATED METALB-DECK BACKINGPANEL (PAINTED)2'-0" DIA. CONCRETEHOLD BACK FOOTINGAT WALL END TOALLOW FOR BOLLARDLOCATE OIL ZERKS ATFRONT OF COLLARS (WITHGATE CLOSED) FOROUTSIDE GATE POSTS6" DIA. SCHEDULE 40 STEELPIPE BOLLARD FILLEDW/ CONC. (PAINTED)8x8x16 HONED FACECONCRETE MASONRY UNITWALL, COLOR AS SELECT.BY ARCH. - COORDINATEWITH STRUCTURALREINFORCED CONC.FOUNDATION & FOOTING6" DIA. x1/4" PIPE BOLLARDFILLED W/ CONC.6 YRD DUMPSTEROR BIN swstvwetoetoetoetoetoetoetoetoetoetoeTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPtoetoetoetoetoetoetoe toe toetoetoetoetoetoetoetoetoetoetoetoetoetoetoetoetoetoeTOPTOPTOPTOPTOPTOPTOPTOPTOP TOPtoetoetoetoetoetoetoetoetoetoetoetoetoetoeTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPTOPtoetoetoetoetoetoetoetoetoetoetoetoe19.3'12.7'E LANARK STADVANCED HEATING AND COOLING2640 E LANARKTRASH ENCLOSURE50'020'40'PLAN SCALE: 1" = 20'ADVANCED HEATING AND COOLINGDATE: 06.25.2021DESIGNED: HEHE012640 E LANARK ST, MERIDIAN, IDAHO 83642SITE PLANBALL VENTURES AHLQUIST208.616.1050WWW.BVADEV.COMNREPUBLIC SERVICES APPROVAL . . 1 1 2 2 3 3 4 4 5 5 6 6 BB CC 7 7 8 8 AA WOMENS 129 MENS 128 BREAK 132 OFFICE 117 OFFICE 116 OFFICE 115 RECEPTION 118 OFFICE 120 ELEC / IT 127 OFFICE 112 MECH 125 OFFICE 102 OFFICE 103 CONFERENCE 108 MENS 110 OFFICE 113 OFFICE 114 JANITOR 123 CONFERENCE 119 COPY 122 SERVICE STORAGE STAGING 111 OFFICE 106 OFFICE 107 WOMENS 109 FLEX 104 DD 9 9 178' - 4" 25' - 0"25' - 0"25' - 0"25' - 0"25' - 0"25' - 0"25' - 0"3' - 4"2' - 8"96' - 0"20' - 0"118' - 8"Date Project Number 2775 W. Navigator Drive Suite #220 Meridian, ID 83642 208.616.1050 CONSULTANT STAMP SHEET TITLE SHEET NUMBER COPYRIGHT © 2019 6/29/2021 11:32:38 AMP101 FLOOR PLAN LEVEL ONE2640 E. LanarkADVANCED HEATING AND COOLING06.28.2021 Project Number Project Status No. Description Date 1/8" = 1'-0"1 FLOOR PLAN LEVEL ONE - PRESENTATION 1 1 2 2 3 3 4 4 5 5 6 6 BB CC 7 7 8 8 AA DD 9 9 OFFICE 211 OPEN OFFICE 201 STORAGE 210 COPY 209 OFFICE 208 OFFICE 207 OFFICE 206 OFFICE 205 OFFICE 204 OFFICE 203 OFFICE 202 25' - 0"25' - 0"25' - 0"25' - 0"25' - 0"25' - 0"25' - 0"3' - 4" 178' - 4"2' - 8"96' - 0"20' - 0"118' - 8"Date Project Number 2775 W. Navigator Drive Suite #220 Meridian, ID 83642 208.616.1050 CONSULTANT STAMP SHEET TITLE SHEET NUMBER COPYRIGHT © 2019 6/29/2021 11:32:38 AMP102 FLOOR PLAN LEVEL TWO2640 E. LanarkADVANCED HEATING AND COOLING06.28.2021 Project Number Project Status No. Description Date 1/8" = 1'-0"1 FLOOR PLAN LEVEL TWO - PRESENTATION swstvweUPE.LANARK ST.LANDSCAPE ARCHITECTDEVELOPERLANDSCAPE MATERIALSLANDSCAPE LEGENDPLANT SCHEDULEgreg@baerdg.comPh. 208.859.19806.25.2021L1.0City of Boise DR Landscape Plan Advanced Heating and Air Boise IdahoScale 1" = 20'-0"CZC LANDSCAPE PLAN02040#KEYNOTES1234 greg@baerdg.comPh. 208.859.19806.25.2021L1.1City of Boise DR Landscape Details Advanced Heating and Air Boise Idaho1CONIFER TREE DETAIL2TREE PLANTING DETAIL7EDGING DETAIL4TRASH RECEPTICLE (WITH ASH PAN)3BENCH6SHRUB PLANTING DETAIL5BOULDER PLACEMENT DETAILGENERAL IRRIGATION NOTES - AGENCY SUBMITTALGENERAL LANDSCAPE NOTES - AGENCY SUBMITTAL Statistics Description Symbol Avg Max Min Max/Min Avg/Min SITE - CALCULATION ZONE 1 2.3 fc 15.7 fc 0.0 fc N/A N/A Schedule Symbol Label Image Quantity Manufacturer Catalog Number Description Number Lamps Lumens Per Lamp Light Loss Factor Wattage Plot A12 1 COOPER LIGHTING SOLUTIONS - McGRAW- EDISON (FORMERLY EATON) GALN-SA2C-740-U-T2 GALLEON AREA AND ROADWAY LUMINAIRE (2) 70 CRI, 4000K, 1050mA LIGHTSQUARES WITH 16 LEDS EACH AND TYPE II OPTICS 32 444 1 108 A13 4 COOPER LIGHTING SOLUTIONS - McGRAW- EDISON (FORMERLY EATON) GALN-SA2C-740-U-T3 GALLEON AREA AND ROADWAY LUMINAIRE (2) 70 CRI, 4000K, 1050mA LIGHTSQUARES WITH 16 LEDS EACH AND TYPE III OPTICS 32 438 0.95 108 SMC 3 COOPER LIGHTING SOLUTIONS - LUMARK (FORMERLY EATON) RPGC25S - POSITION 1 ROUND PARKING GARAGE LUMEN SELECT 1 6124 1 48.72 WP1 4 COOPER LIGHTING SOLUTIONS - LUMARK (FORMERLY EATON) XTOR6B-W CROSSTOUR 58W WALL MOUNT LED 1 6036 0.95 58 WP2 11 COOPER LIGHTING SOLUTIONS - LUMARK (FORMERLY EATON) XTOR8B-W CROSSTOUR 81W WALL MOUNT LED 1 8371 1 81 FLOW FLOW 1 1 2 2 3 3 4 4 5 5 6 6 B B C C 7 7 8 8 D D 9 9 SEWER STORM DRAIN STORM DRAIN STORM DRAIN STORM DRAIN CO WATER 0.3 0.3 0.3 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.1 0.1 0.2 0.4 0.5 0.6 0.6 0.5 0.2 0.1 0.1 0.3 0.6 0.6 0.6 0.6 0.5 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.3 0.5 0.8 1.0 1.1 0.9 0.4 0.1 0.1 0.1 0.5 1.0 1.1 1.1 1.0 0.7 0.6 0.5 0.4 0.4 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.3 0.7 1.2 1.6 1.8 1.5 0.5 0.1 0.1 0.2 0.9 1.7 1.8 1.7 1.4 1.1 1.0 0.9 1.0 0.9 0.9 0.8 0.8 0.8 0.7 0.6 0.5 0.4 0.3 0.5 0.9 1.5 2.1 2.4 2.1 0.7 0.2 0.3 0.4 1.3 2.4 2.5 2.2 1.8 1.7 1.7 1.7 1.8 1.8 1.7 1.5 1.6 1.6 1.3 1.1 0.9 0.6 0.4 0.5 1.0 1.6 2.3 3.0 2.7 1.2 0.3 0.4 0.8 2.0 3.2 2.9 2.4 1.9 2.1 3.5 4.1 3.7 3.3 3.5 3.4 3.0 2.8 3.1 2.8 1.9 0.8 0.5 0.6 1.0 1.6 2.3 3.0 2.8 1.9 0.3 0.5 1.2 2.7 3.2 3.0 2.4 2.0 2.5 6.5 10.2 7.3 4.6 8.0 8.8 5.1 4.5 7.8 7.3 3.2 0.9 0.4 0.6 1.0 1.7 2.3 3.0 2.9 2.1 0.3 0.6 1.4 2.9 3.3 3.2 2.6 2.0 2.3 6.0 12.0 6.9 4.0 9.7 11.8 5.0 4.7 11.2 10.5 3.5 0.9 0.4 0.6 1.1 1.7 2.3 3.3 2.7 1.4 0.3 0.5 1.0 2.5 3.7 3.4 2.8 2.0 1.4 0.2 0.3 0.4 0.7 1.1 1.7 2.3 2.6 2.1 0.7 0.2 0.4 0.6 2.0 3.3 3.5 3.5 3.0 2.6 0.9 1.0 1.0 1.0 1.2 1.5 1.9 2.1 1.6 0.4 0.2 0.2 0.4 1.5 2.9 3.4 4.0 5.7 7.8 4.0 4.0 2.4 1.5 1.2 1.2 1.3 1.3 1.0 0.3 0.2 0.2 0.3 1.1 2.3 3.0 3.8 7.3 13.8 11.9 8.6 3.5 1.8 1.2 0.9 0.8 0.7 0.6 0.2 0.1 0.2 0.2 0.3 0.9 2.0 2.8 3.5 6.1 9.2 11.9 9.3 4.3 2.1 1.2 0.7 0.5 0.4 0.3 0.1 0.2 0.2 0.3 0.4 0.7 1.9 2.5 2.9 3.2 3.3 10.9 9.2 4.6 2.3 1.3 0.6 0.4 0.3 0.2 0.1 0.2 0.2 0.3 0.5 0.8 2.0 2.4 2.9 3.1 3.0 14.1 9.6 4.2 2.2 1.2 0.6 0.3 0.2 0.1 0.1 0.2 0.3 0.4 0.7 1.0 2.1 2.4 3.4 6.2 8.2 11.0 9.1 4.6 2.3 1.3 0.5 0.3 0.2 0.1 0.1 0.2 0.3 0.5 0.9 1.1 1.9 2.2 3.7 8.4 13.8 14.1 9.3 4.3 2.2 1.2 0.5 0.3 0.2 0.1 0.1 0.2 0.3 0.6 0.9 1.1 1.9 2.3 3.5 6.4 8.4 13.1 9.0 4.4 2.2 1.2 0.6 0.3 0.2 0.1 0.1 0.2 0.3 0.5 0.7 1.0 2.0 2.2 2.6 2.9 2.8 12.4 9.0 4.6 2.4 1.3 0.6 0.4 0.3 0.2 0.1 0.2 0.2 0.3 0.5 0.9 1.9 2.1 2.6 2.6 2.2 15.7 9.7 4.6 2.4 1.4 0.8 0.5 0.4 0.3 0.2 0.2 0.3 0.4 0.8 1.9 2.3 3.4 7.0 7.9 10.8 9.1 5.1 2.6 1.6 1.0 0.8 0.6 0.4 0.1 0.2 0.2 0.4 1.0 2.0 2.5 3.7 10.0 15.5 6.5 7.0 4.8 2.7 1.7 1.3 1.2 1.1 0.7 0.1 0.2 0.2 0.5 1.4 2.3 3.0 3.9 5.3 4.3 5.6 6.2 4.3 2.6 1.9 1.8 1.9 1.7 1.1 0.2 0.2 0.3 0.6 2.0 2.9 3.5 4.4 6.7 4.4 5.5 6.2 4.1 2.5 2.0 2.2 2.4 2.5 1.5 0.2 0.3 0.5 0.9 2.5 3.3 3.6 4.6 11.4 12.2 5.3 5.7 3.8 2.3 2.0 2.3 2.8 3.1 2.0 0.3 0.4 0.7 1.7 3.1 3.8 3.5 4.0 6.1 3.8 4.6 4.9 3.1 2.0 1.9 2.3 2.8 3.0 2.6 0.3 0.4 0.9 2.3 3.2 3.5 3.1 2.7 2.8 6.5 11.1 7.0 4.8 15.6 14.6 13.4 10.4 7.7 12.8 11.8 5.9 3.5 2.2 1.6 1.8 2.2 2.9 3.0 2.7 0.3 0.4 0.9 2.2 3.1 3.4 2.7 2.2 2.1 3.4 4.4 3.6 3.5 5.8 7.2 6.2 5.7 5.4 6.3 6.0 3.5 1.9 1.3 1.3 1.6 2.2 2.9 3.1 2.2 0.2 0.4 0.6 1.4 3.0 3.2 2.6 2.0 1.6 1.6 1.5 1.6 1.9 2.2 2.9 2.7 2.8 2.9 2.6 2.4 1.9 1.2 0.9 1.0 1.5 2.1 2.5 2.6 1.4 0.2 0.2 0.3 0.9 2.3 2.6 2.3 1.7 1.2 0.9 0.7 0.8 0.9 1.0 1.2 1.2 1.4 1.4 1.2 1.1 0.9 0.7 0.6 0.8 1.3 1.7 2.1 1.9 0.9 0.1 0.1 0.2 0.7 1.6 1.9 1.7 1.3 0.9 0.5 0.3 0.3 0.3 0.3 0.4 0.5 0.6 0.6 0.6 0.5 0.5 0.4 0.4 0.6 0.9 1.2 1.3 1.2 0.6 0.1 0.1 0.1 0.5 1.0 1.2 1.1 1.0 0.7 0.4 0.2 0.2 0.2 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.5 0.6 0.7 0.8 0.7 0.4 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.3 0.4 0.4 0.4 0.4 0.2 A13 @ 25' A13 @ 25' A13 @ 25' A13 @ 25' WP2 @ 16' WP2 @ 16'WP2 @ 16'WP2 @ 16'WP2 @ 16' WP2 @ 16' WP2 @ 16' WP2 @ 16'WP2 @ 16'WP1 @ 12'WP1 @ 12' WP1 @ 12' WP1 @ 12' WP2 @ 16' WP2 @ 16' SMC @ 13'SMC @ 13'SMC @ 13' A12 @ 25' 1040 N 2200 WEST SALT LAKE CITY UTAH T:801.359.3158 www.pve-ut.com Date Project Number 2775 W. Navigator Drive Suite #220 Meridian, ID 83642 208.616.1050 CONSULTANT STAMP SHEET TITLE SHEET NUMBER COPYRIGHT © 2021 NOT FOR CONSTRUCTION 6/29/2021 8:37:03 AME102 PHOTOMETRIC SITE PLAN2640 E. LanarkADVANCED HEATING AND COOLING06.29.2021 21078.01 PRELIMINARY No. Description Date 0'8'16'32'64' SCALE: 1/16" = 1'-0"E102 1 SITE PHOTOMETRICS N S EW LEVEL 1 0' -0" LEVEL 1 0' -0" LEVEL 2 12' -0" LEVEL 2 12' -0" BC AD METAL PANEL FIELD COLORSTOREFRONT METAL PANEL ACCENT COLOR METAL ROOOF PANEL ACCENT COLOR METAL ROOOF PANEL ACCENT COLOR LEVEL 1 0' -0" LEVEL 1 0' -0" LEVEL 2 12' -0" LEVEL 2 12' -0" B C D METAL PANEL FIELD COLORSTOREFRONT METAL PANEL ROOF ACCENT COLOR HOLLOW METAL DOOR LEVEL 1 0' -0" LEVEL 1 0' -0" LEVEL 2 12' -0" LEVEL 2 12' -0" 123456789 METAL PANEL FIELD COLOR STOREFRONT METAL ROOF PANEL ACCENT COLOR OVERHEAD COILING DOOR HOLLOW METAL DOORSTOREFRONTHOLLOW METAL DOOR BOLLARD LEVEL 1 0' -0" LEVEL 1 0' -0" LEVEL 2 12' -0" LEVEL 2 12' -0" 1 2 3 4 5 6 7 8 9 METAL PANEL ACCENT COLOR METAL ROOF PANEL ACCENT COLOR STOREFRONT STOREFRONT ENTRANCEMETAL PANEL FIELD COLORBOLLARDOVERHEAD COILING DOORHOLLOW METAL DOOR Date Project Number 2775 W. Navigator Drive Suite #220 Meridian, ID 83642 208.616.1050 CONSULTANT STAMP SHEET TITLE SHEET NUMBER COPYRIGHT © 2019 6/29/2021 11:34:02 AMP201 EXTERIOR ELEVATIONS2640 E. LanarkADVANCED HEATING AND COOLING06.28.2021 Project Number Project Status No. Description Date 1/8" = 1'-0"1 EAST ELEVATION 1/8" = 1'-0"2 WEST ELEVATION 1/8" = 1'-0"3 NORTH ELEVATION 1/8" = 1'-0"4 SOUTH ELEVATION 5 FRONT PERSPECTIVE 6 BIRDS EYE PERSPECTIVE †QUESTIONS? Contact the Planning Division at 33 E Broadway Ave, Suite 102, Meridian ID 83642, or 208.884.5533, or https://meridiancity.org/design, or planning@meridiancity.org. Last Modified: 11/25/19 Architectural Standards D esign R eview C heCklist | n on -R esi Dential Page | 1 Cohesive Design, non -ResiDential stanDaRDs (CDs) If a “N” or “N/A” is checked, must explain in comments. Design standard exceptions require seperate narrative. Y N N/A ID #Description Comments Intent 1.00 Promote visually aesthetic building designs that incorporate quality architectural characteristics and establish built environments that are compatible with existing, planned, and anticipated adjacent land uses. Goal 1.10 Articulate building designs to frame and accentuate public spaces with pedestrian scale elements and details. Goal 1.11 Building design should address building scale, mass, form, and use a variety of materials and architectural features to ensure an aesthetic contribution compatible with surrounding buildings. 1.1A Maintain consistent and contiguous pedestrian environments across developments. Limit circuitous connections and maintain clear visibility. 1.1B Provide pedestrian connections to non-private public spaces. 1.1C Incorporate architectural features on all sides of a building façade facing: the primary entrance(s) of an adjacent building, public roadways, interior site amenities, and façades that are visible from public spaces. See Architectural Elements, Building Form, and Materials sections. 1.1D Buildings must orient, frame, and/or direct pedestrian views to adjacent cultural buildings, parks, and plazas. 1.1E Design and orient buildings not to impede access. The build- ing should enhance the appeal of open space and pedestrian environments Note: For a complete list of all Standards, along with photo examples, see the City of Meridian Architectural Standards Manual. Project Name: Applicant/Agent: File # Date:OFFICIAL USE †NON-RESIDENTIAL STANDARDS | COMMERCIAL DISTRICTS †PROJECT INFORMATION †QUESTIONS? Contact the Planning Division at 33 E Broadway Ave, Suite 102, Meridian ID 83642, or 208.884.5533, or https://meridiancity.org/design, or planning@meridiancity.org. Last Modified: 11/25/19 Architectural Standards D esign R eview C heCklist | n on -R esi Dential Page | 2 Cohesive Design, non -ResiDential stanDaRDs (CDs) If a “N” or “N/A” is checked, must explain in comments. Design standard exceptions require seperate narrative. Y N N/A ID #Description Comments Goal 1.20 Design building façades to express architectural character and incorporate the use of design principles to unify developments and buildings, and relate to adjacent and surrounding uses. 1.2A Comply and adhere with all previously required building design elements that were included as part of a Development Agree- ment, Conditional Use Permit, and/or other requirements as part of prior approval. Goal 1.30 Incorporate design principles to include rhythm, repetition, framing, and/or proportion. Applies to all sides of a building façade facing public roadways, that are visible from residential neighborhoods or public spaces, or facing the public entry of an adjacent building. 1.3A Integrate at least one material change, color variation, or horizontal reveal for every 12-vertical feet of building façade; vertical spacing may be averaged over façade. 1.3B Integrate at least one material change, color variation, or vertical reveal every 50-horizontal feet of building façade; horizontal spacing may be averaged over façade elevation. Note: For a complete list of all Standards, along with photo examples, see the City of Meridian Architectural Standards Manual. BuilDing sCale, non -ResiDential stanDaRDs (Bss) If a “N” or “N/A” is checked, must explain in comments. Design standard exceptions require seperate narrative. Y N N/A ID #Description Comments Intent 2.00 Promote building designs that use appropriate architectural and pedestrian scales to establish compatible physical and visual relationships with adjacent and surrounding developments and reinforce a cohesive built environment. Goal 2.10 Development should consider the scale of surrounding buildings, including relationships to existing residential areas, as well as an appropriate height, mass, and form scaled for the built environment. Applies to façades of development along public roads, public spaces, and adjacent to residential areas. 2.1A Buildings with rooflines 50-feet in length or greater must incor- porate roofline and parapet variations. Variations may include step-downs, step-backs, other modulation, or architectural features such as cornices, ledges, or columns, and must occur in total combination for at least 20% of the façade length. May be averaged over entire façade, but may not exceed 75-feet without a break. Note: For a complete list of all Standards, along with photo examples, see the City of Meridian Architectural Standards Manual. †COMMERCIAL DISTRICTS | CONTINUED †QUESTIONS? Contact the Planning Division at 33 E Broadway Ave, Suite 102, Meridian ID 83642, or 208.884.5533, or https://meridiancity.org/design, or planning@meridiancity.org. Last Modified: 11/25/19 Architectural Standards D esign R eview C heCklist | n on -R esi Dential Page | 3 BuilDing sCale, non -ResiDential stanDaRDs (Bss) If a “N” or “N/A” is checked, must explain in comments. Design standard exceptions require seperate narrative. Y N N/A ID #Description Comments 2.1B For buildings with façades longer than 200-feet, reduce massing of buildings by grouping or incorporating smaller tenant spaces along the commercial façade, or by incorporating at least one significant modulation with depth at least 3% of the total façade length or 10-feet, and a width in combination at least 20% of the façade length. 2.1D Within mixed use areas and for all developments along arterial roadways, buildings over 1,000 sqft must provide a minimum 20-foot building elevation to include average parapet height, ridge of a pitched roof, or tower/turret type elements at least 20% in total of overall façade width. Goal 2.20 Physically configure building designs to reduce disproportioned architectural scale relative to adjacent uses. Applies to façades of development along public roads, public spaces, and residential areas. 2.2A For adjacent buildings with greater than 1-story height disparity (i.e. – two or more stories difference) and within 30-feet of each other, integrate and align parapet designs, material changes, fenestration alignment, material reveals, or other architectural elements and horizontal articulation, to relate varying building heights to one another. Aligned features do not have to be the same type (i.e. window pattern on one could align with parapet on another). 2.2B Use pedestrian scale and landscape design elements such as specialty lighting, awnings, trees or other site elements to visu - ally relate and transition multi-story buildings (or equivalent) to the ground plane. Goal 2.30 Incorporate pedestrian-scale architectural features to support an aesthetic character that contributes to the quality of the build- ing design and connectivity with the surrounding environment. Applies to façades in developments: visible from arterial or collector roadways, adjacent to residential developments facing roadways, facing an adjacent building's primary building entries, and adjacent to public spaces. 2.3A Consistently incorporate at least two (2) architectural features into the building design that are pedestrian scale, to include: fenestration patterns; architectural elements such as ledges, lighting, or canopies; material or pattern banding; or detailing (see Pedestrian Scale definition). Note: For a complete list of all Standards, along with photo examples, see the City of Meridian Architectural Standards Manual. †COMMERCIAL DISTRICTS | CONTINUED †QUESTIONS? Contact the Planning Division at 33 E Broadway Ave, Suite 102, Meridian ID 83642, or 208.884.5533, or https://meridiancity.org/design, or planning@meridiancity.org. Last Modified: 11/25/19 Architectural Standards D esign R eview C heCklist | n on -R esi Dential Page | 4 BuilDing FoRm, non-ResiDential stanDaRDs (BFs) If a “N” or “N/A” is checked, must explain in comments. Design standard exceptions require seperate narrative. Y N N/A ID #Description Comments Intent 3.00 Promote building designs that articulate and define appropriate building forms with visual interest and enhance the character of the built environment. Goal 3.10 Articulate building forms, including but not limited to massing, walls, and roofs, with appropriately scaled modulations that contribute to the development of aesthetic building designs. Applies to façades in developments: along arterial and collector roadways, adjacent to residential developments facing roadways, facing public entries of adjacent buildings, and visible from public spaces. 3.1A Incorporate at least one type of the following modulations in the façade plane, including but not limited to projections, recesses, and step backs that articulate wall planes and break up building mass. Examples include but are not limited to columns with trim or accent materials, change in finished material depths, building overhangs, and inset features and materials such as false windows or fenestration with architectural accents. 3.1B Qualifying modulation must be at least 6-inches in depth, be at least 8-inches in width or height (whichever is narrowest), and occur in total for 20% of overall façade elevation. For buildings with façades less than 150-feet, horizontal modulation must occur no less than every 30-feet. For buildings with façades greater than or equal to 150-feet, horizontal modulation must occur no less than every 50-feet. 3.1C Design parking structure façades as site integrated buildings, meeting applicable Manual standards for Architectural Elements and Material sections. Goal 3.20 Incorporate visual and physical distinctions in the building design that enhance building forms, articulate façades, identify entries, integrate pedestrian scale, and visually anchor the building to the ground or street level. Applies to building façades visible from a public street or public space, and to façades with public entries. 3.2A For at least 30% of applicable façades use any combination of concrete, masonry, stone, or unique variation of color, texture, or material, at least 10-inches in height, around the base of the building. May alternatively incorporate other architectural features such as ledges, façade reveals, ground level fenestra- tion, raised planters, or landscaping elements within 3-feet of finished grade. Note: For a complete list of all Standards, along with photo examples, see the City of Meridian Architectural Standards Manual. †COMMERCIAL DISTRICTS | CONTINUED †QUESTIONS? Contact the Planning Division at 33 E Broadway Ave, Suite 102, Meridian ID 83642, or 208.884.5533, or https://meridiancity.org/design, or planning@meridiancity.org. Last Modified: 11/25/19 Architectural Standards D esign R eview C heCklist | n on -R esi Dential Page | 5 BuilDing FoRm, non-ResiDential stanDaRDs (BFs) If a “N” or “N/A” is checked, must explain in comments. Design standard exceptions require seperate narrative. Y N N/A ID #Description Comments 3.2B Where building designs incorporate multiple stories, or multiple floor height equivalents, integrate at least one field or accent color, material, or architectural feature used on lower stories, on the upper stories. 3.2C Building designs with multiple stories must provide proportion- ally taller ground-level façades adjacent to public roadways and public spaces. Provide floor-to-ceiling heights, or floor-to-floor from 10 to 16 feet. 3.2D In mixed-use areas and for structures greater than four stories, design the uppermost story or façade wall plane to include material changes, horizontal articulation, and modulation meeting first story requirements, or include a patio, rooftop garden, penthouse, or strong architectural feature such as a tower element. Goal 3.30 Building design should establish visual connections that relate internal spaces at ground- or street-level with facades adjacent to public roadways, public spaces, and along primary building entries, and that add visual interest and complexity to the first floor building design. 3.3A Use horizontal and/or vertical divisions in wall planes, such as ledges, awnings, recesses, stringcourse, molding, joint lines, or other material types, to frame and accent 30% or more of total fenestration. 3.3D Average 30% fenestration for applicable first floor façade, unless specified elsewhere. May also meet fenestration alternative (see 3.3E). Big box and buildings in industrial districts may limit applicable façade area to 30-feet around public entries. 3.3E Fenestration Alternative: Incorporate doors and windows for at least 30% of applicable first floor façade, or suggest their inclu- sion using faux treatments that incorporate at least two of the following: material changes, reveals in conjunction with color or material change, qualifying modulation such as recessed areas, architectural trellis, awnings and canopies over access areas, detached structures such as pergola, or similar architectural features and details. Goal 3.40 Building roof types, forms, and elements should provide variation and interest to building profiles and contribute to the architectural identity of the buildings, without creating an imposing scale on adjacent uses. Applies to façades: in development along arterial roadways, visible from residential development, adjacent to public spaces, facing public entries of adjacent buildings. Note: For a complete list of all Standards, along with photo examples, see the City of Meridian Architectural Standards Manual. †COMMERCIAL DISTRICTS | CONTINUED †QUESTIONS? Contact the Planning Division at 33 E Broadway Ave, Suite 102, Meridian ID 83642, or 208.884.5533, or https://meridiancity.org/design, or planning@meridiancity.org. Last Modified: 11/25/19 Architectural Standards D esign R eview C heCklist | n on -R esi Dential Page | 6 BuilDing FoRm, non-ResiDential stanDaRDs (BFs) If a “N” or “N/A” is checked, must explain in comments. Design standard exceptions require seperate narrative. Y N N/A ID #Description Comments 3.4A For flat roofs, incorporate primary and secondary roof elements including but not limited to: multiple material types along para - pets, multiple parapet elevations with at least 1-foot change in elevation, or modulation of at least 2-feet in the parapet, such as along entryway overhangs. Qualifying elements must exist for at least 20% the length of applicable façades. May also incorporate secondary roof types, such as hip roofs along overhangs. 3.4B For sloped roofs, incorporate at least two of any one roof element, including but not limited to: valleys, ridges, or gables. Qualifying elements in total must exist for at least 20% of applicable façade roof area and be visible from the same façade elevation. May also incorporate other roof styles, such as parapet walls over entryway features. 3.4C Provide variation in roof profile over façade modulation and/ or articulation over façade material/color transitions. Options include, but are not limited to: varying parapet heights; two or more roof planes; continuation of façade modulation through roof lines; dormers; lookouts; overhang eaves; sloped roofs; or cornice work. Note: For a complete list of all Standards, along with photo examples, see the City of Meridian Architectural Standards Manual. aRChiteCtuRal elements, non-ResiDential stanDaRDs (ase) If a “N” or “N/A” is checked, must explain in comments. Design standard exceptions require seperate narrative. Y N N/A ID #Description Comments Intent 4.00 Promote integrated architectural elements and details as compo- nents of cohesive building designs that enhance the visual interest of building façades, support activity at and/or near ground level, and provide pedestrian scale. Goal 4.10 Use proportional architectural elements and detailing to articulate façades, and contribute to an aesthetic building character with a high level of pedestrian design. Applies to façades: in development along public roadways, visible from residential development, adjacent to public spaces, facing public entries of adjacent buildings. Goal 4.11 Design and articulate architectural elements using proportions, divisions, detailing, materials, textures, and colors and appropriately integrate these elements into the building design. Applies to façades: in development along public roadways, visible from residential development, adjacent to public spaces, facing public entries of adjacent buildings. Note: For a complete list of all Standards, along with photo examples, see the City of Meridian Architectural Standards Manual. †COMMERCIAL DISTRICTS | CONTINUED †QUESTIONS? Contact the Planning Division at 33 E Broadway Ave, Suite 102, Meridian ID 83642, or 208.884.5533, or https://meridiancity.org/design, or planning@meridiancity.org. Last Modified: 11/25/19 Architectural Standards D esign R eview C heCklist | n on -R esi Dential Page | 7 aRChiteCtuRal elements, non-ResiDential stanDaRDs (ase) If a “N” or “N/A” is checked, must explain in comments. Design standard exceptions require seperate narrative. Y N N/A ID #Description Comments 4.1A Provide at least three detailing elements that transition façade material changes or integrate pedestrian scale elements, such as doorways, windows, or material banding, at the base of the building. Examples include but are not limited to: cornice work around primary entries, decorative caps on brick or stone banding, architectural canopies over entries, or decorative lintels above the first floor windows. 4.1B Provide building overhangs or other projections such as canopies which articulate the building façade and provide temporary relief from inclement weather. At a minimum, an overhang or projection is required within 20-feet of all public entryways, must be at least 3-feet in depth from the point of entry, and be least 6-feet in length. Entryways with vestibules or other permanent enclosed transition space are exempt. 4.1C Provide details that emphasize focal elements such as public entries, building corners, or public spaces. Examples include but are not limited to: columns, quoin or rustication, canopies over entries, lintels, transom windows, or modulation of the roof plane. At least one focal element is required and must be accented with a unique combination of color, texture, materials, or modulation in the wall or roof plane. Goal 4.20 Building designs must not create blank wall segments when visible from a public street or public spaces. Consider the treatment at the base, middle, and top of the façade. 4.2A Use any combination of standards from Building Form, Architec - tural Elements, or Material sections to provide pattern, color, or material variation on all wall segments. Must not exceed 30-feet horizontally or vertically without building variation. Goal 4.30 Organize building service equipment, including, but not limited to, utility, service, and mechanical, away from building entries, roadways, public spaces, and, where appropriate, from adjacent buildings. 4.3A Use and integrate standards from the Architectural Standards Manual to screen and conceal service and mechanical equipment. Landscaping meeting the same intent may also be considered for utility meters and connections. 4.3B All ground level mechanical equipment must be screened to the height of the unit as viewed from the property line. Note: For a complete list of all Standards, along with photo examples, see the City of Meridian Architectural Standards Manual. †COMMERCIAL DISTRICTS | CONTINUED †QUESTIONS? Contact the Planning Division at 33 E Broadway Ave, Suite 102, Meridian ID 83642, or 208.884.5533, or https://meridiancity.org/design, or planning@meridiancity.org. Last Modified: 11/25/19 Architectural Standards D esign R eview C heCklist | n on -R esi Dential Page | 8 aRChiteCtuRal elements, non-ResiDential stanDaRDs (ase) If a “N” or “N/A” is checked, must explain in comments. Design standard exceptions require seperate narrative. Y N N/A ID #Description Comments 4.3C All rooftop mechanical equipment shall be screened as viewed from the farthest edge of the adjoining right of way. Note: For a complete list of all Standards, along with photo examples, see the City of Meridian Architectural Standards Manual. mateRials, non-ResiDential stanDaRDs (mas) If a “N” or “N/A” is checked, must explain in comments. Design standard exceptions require seperate narrative. Y N N/A ID #Description Comments Intent 5.00 Use quality materials and colors that promote aesthetic building designs and contribute to the development of a timeless com- munity character. Goal 5.10 Use complementary material combinations that contribute to a cohesive building design. Use materials from the following basic groups: wood, masonry, concrete, stucco, metal, and glazing. 5.1A For buildings with façades that face multiple public roadways and/or public spaces, use consistent material combinations, material quality, and architectural detailing. 5.1B For all façade elevations visible from public roads, public spaces, primary entrance(s) of an adjacent building, and facing residential districts, use at least two distinct field materials, colors, or material-color combinations on the building façade (see also Material definitions). 5.1D For façade elevations visible from public roadways and along primary building entryways, incorporate an accent material on the first story. 5.1E Distinguish field materials from accent materials through pat- tern, texture, or additional detail visible from edge of nearest roadway. Alternate masonry or material courses with relief from primary plane may count toward this. 5.1F Where materials transition or terminate, provide detailing to express the natural appearance of the material. For example, wrap stone or stone-like products around visible corners to convey the appearance of mass, and not as a thin veneer. Note: For a complete list of all Standards, along with photo examples, see the City of Meridian Architectural Standards Manual. †COMMERCIAL DISTRICTS | CONTINUED †QUESTIONS? Contact the Planning Division at 33 E Broadway Ave, Suite 102, Meridian ID 83642, or 208.884.5533, or https://meridiancity.org/design, or planning@meridiancity.org. Last Modified: 11/25/19 Architectural Standards D esign R eview C heCklist | n on -R esi Dential Page | 9 mateRials, non-ResiDential stanDaRDs (mas) If a “N” or “N/A” is checked, must explain in comments. Design standard exceptions require seperate narrative. Y N N/A ID #Description Comments 5.1G Non-durable materials, treatments, and finishes that deteriorate quickly with weather, ultra-violet light, and that are more suscep - tible to wear and tear are prohibited on permanent structures. 5.1H The use of vinyl and ordinary smooth face block, unfinished, colored, or painted, are prohibited as a field materials for building façades along public roadways, adjacent to public spaces, and when visible from residential neighborhoods. Smooth face block may be used as an accent material. 5.1I Untextured concrete panels and prefabricated steel panels are prohibited as field materials for building façades, except when used with a minimum of two other qualifying field materials and meeting all other standard fenestration and material requirements. Goal 5.20 Use colors that complement building materials and support innova- tive and good design practices. Applies to building façades visible from a public street, public spaces, and pedestrian environments. 5.2A Use of subtle, neutral, or natural tones must be integrated with at least one accent or field material. 5.2B Use of intensely saturated colors or fluorescence is prohibited as a primary material. May be used as an accent material. 5.2C Materials or colors with high reflectance, such as some metals or reflective glazing, must not redirect light towards roadways, public spaces, or adjacent uses in a way which constitutes a public nuisance or safety hazard. Goal 5.30 Integrate roll-up doors, will-call doors, drive-through doors, and loading docks into the building design, and locate them in a manner which does not create pedestrian, drive aisle, or roadway conflicts. Applies to façades along arterial and collector roadways, and façades facing public spaces. 5.3A For commercial and traditional neighborhood districts, roll-up and drive-through doors are allowed when integrated into the building design, but will-call doors with roll-ups and loading docks are prohibited. Consider material variation and transitions, modulation, and other architectural features and standards for the design. Note: For a complete list of all Standards, along with photo examples, see the City of Meridian Architectural Standards Manual. †COMMERCIAL DISTRICTS | CONTINUED †QUESTIONS? Contact the Planning Division at 33 E Broadway Ave, Suite 102, Meridian ID 83642, or 208.884.5533, or https://meridiancity.org/design, or planning@meridiancity.org. Last Modified: 11/25/19 Architectural Standards D esign R eview C heCklist | n on -R esi Dential Page | 10 signs & lighting, non -ResiDential stanDaRDs (sls) If a “N” or “N/A” is checked, must explain in comments. Design standard exceptions require seperate narrative. Y N N/A ID #Description Comments Intent 6.00 Integrate signs and architectural lighting as cohesive elements of building designs that contribute to the atmosphere of the built environment and enhance safety. Goal 6.10 Use lighting on building exteriors to promote safe pedestrian environments along roadways, at intersections, and in public spaces. 6.1A Lighting fixture spacing and height along streetscapes and roadways must be placed to avoid conflicts with tree plantings. 6.1B Use energy-efficient architectural lighting. 6.1C Use lighting fixtures that are consistent with other decorative hardware on the building. For example, select lighting hardware with similar color and shape as other building hardware, use recessed lighting, incorporate uniform spacing, integrate with other accents and reveals, and coordinate specialty lights with predominate architectural features. Note: For a complete list of all Standards, along with photo examples, see the City of Meridian Architectural Standards Manual. †COMMERCIAL DISTRICTS | CONTINUED