Loading...
Photometric PlanELECTRICAL CONTRACTOR SHALL COORDINATE EXACT ROUTING AND ELEVATION OF UNDERGROUND DUCTBANKS AND CONDUITS WITH ALL OTHER TRADES ON SITE PRIOR TO EXCAVATION AND INSTALLATION. ALL TRENCHING, BACKFILL, PATCHING, ETC., SHALL BE BY THE ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. ALL PRIMARY UTILITY CABLING SHALL BE INSTALLED BY THE RESPECTIVE UTILITY COMPANIES.COORDINATION OF UNDERGROUND WORKDO ALL EXCAVATION AND BACKFILLING NECESSARY FOR INSTALLATION OF WORK. PRIOR TO OPENING AN EXCAVATION, EFFORT SHALL BE MADE TO DETERMINE WHETHER UNDERGROUND INSTALLATIONS WILL BE ENCOUNTERED (I.E., TELE-COMMUNICATIONS, SEWER, WATER, FUEL, ELECTRIC LINES, ETC.), AND WHERE SUCH UNDERGROUND INSTALLATIONS ARE LOCATED. WHEN THE EXCAVATION APPROACHES THE ESTIMATED LOCATION OF SUCH INSTALLATIONS, THE EXACT LOCATION SHALL BE DETERMINED. WHEN IT IS UNCOVERED, PROPER SUPPORTS SHALL BE PROVIDED FOR THE EXISTING INSTALLATION. UTILITY COMPANIES SHALL BE CONTACTED AND ADVISED OF THE PROPOSED WORK PRIOR TO THE START OF ACTUAL EXCAVATION. CONTACT THE IDAHO UTILITIES PROTECTION SERVICE 48 HOURS PRIOR TO STARTING WORK. TELEPHONE AT 1-800-342-1585. EXCAVATION AND BACKFILLUTILITY COMPANY CONTACTSPOWER COMPANY: IDAHO POWER REPRESENTATIVE: TYLER MOGENSEN (208) 871-5370 PHONE:©PROFESSIONALENG INEERLICENSED STATEOFIDAHOF RANKA.EISENHOWERP-17537ISSUEDate:Scale:Sheet:DATE1468 West 9th Street, Suite 400, Cleveland,OH 44113 p. 216.687.1555 | f. 216.687.1558 |www.kaczarch.comProject Team:PROJECT:OWNER:Consultant Project #Drawn by:Checked by:As indicated\\bkainc.local\View\Users\mwright\Documents\2020-7055_MEPT_CENTRAL_mwrightMVS2S.rvt7/19/2021 11:59:51 AMNEW HOLIDAY INN EXPRESSHOTEL2920 East Freeway DriveMeridian, IdahoES10207/16/21HLE, Inc.PO BOX 866,800 W Judicial StreetBlackfoot, ID 83221p: 208-785-2977Thorson Baker + Associates3030 West Streetsboro Rd.Richfield, OH 44286p: 330.659.6688ELECTRICAL SITE PHOTOMETRIC PLANCIVIL ENGINEERSTRUCTURAL ENGINEERKarpinski Engineering1274 Hunt RoadAshville, New York 14710P: 716.484.9191MECHANICAL / ELECTRICAL ENGINEERMaurer Construction LLC2621 Connery WayMissoula, MT 59808p: 406.542.6565 fax: 406.542.2848CONSTRUCTION MANAGERInnTrusted, LLC3640 S. Yellowstone HwyIdaho Falls, ID 834022020-7055ALKMPLAN NOTES1 PROVIDE WIRING FOR THE HOTEL SIGN, 2#10AWG, 1 #10GND, IN 1" CONDUIT. ALSO PROVIDE ANOTHER 1" CONDUIT WITH PULLWIRE FOR DATA INSTALLATION. INSTALL A QUAZITE BOX 12" X 18" WITH BOLTED COVER WITH "ELECTRIC" WRITING ON IT. THEJUNCTION BOX SHALL HAVE A SEPARATOR BETWEEN POWER AND DATA. APPROVED EQUALS ARE ACCEPTABLE. COORDINATEWITH ARCHITECT AND OWNER FOR THE EXACT LOCATION OF THE SIGN. COORDINATE CONTROLS WITH OWNER AND SIGNPROVIDER PRIOR TO ROUGH-IN.2 TYPICAL FOR ALL ELECTRIC VEHICLE CHARGING STATIONS. ELECTRIC VEHICLE CHARGING STATIONS MANUFACTURED BY SEMACONNECT MODEL 620 DUAL PEDESTAL. CHARGING STATION PROVIDED BY OWNER, INSTALLED AND WIRED BY EC. PROVIDEWIRING 2#8AWG (EACH STATION, SO 4 #8AWG TOTAL), 1#10GND, IN 1" CONDUIT. DATA REQUIRES CELLULAR COMMUNICATION, NOWIRING IS REQUIRED. COORDINATE WITH ARCHITECT AND OWNER FOR THE EXACT LOCATION OF THE CHARGING STATION.INSTALL BASE AS REQUIRED BY MANUFACTURER, REFER TO MANUAL FOR INSTALLATION DETAILS.3 TYPICAL FOR ALL SITE LIGHTS. PROVIDE A HAND HOLE IN-GROUND JUNCTION BOX FOR THE INSTALLATION OF THE FEEDERS OFSITE LIGHTING. INSTALL A QUAZITE BOX 12" X 18" WITH BOLTED COVER WITH "ELECTRIC" WRITING ON IT. APPROVED EQUALS AREACCEPTABLE. PROVIDE MEANS OF DISCONNECT FOR THE POLE.4 APPROXIMATE LOCATION OF TELECOMMUNICATIONS SERVICE PEDESTAL - PROVIDE (2) 4" CONDUITS FROM PEDESTAL TO FIRSTFLOOR SERVER ROOM FOR TELE/DATA SERVICE PROVIDER CABLING. CONDUITS SHALL STUB UP INTO SERVER ROOM ASINDICATED ON ENLARGED TELECOMMUNICATIONS ROOM PLANS. COORDINATE EXACT LOCATION OF SERVICE PEDESTALCONDUIT STUB WITH UTILITY SERVICE PROVIDER.5 APPROXIMATE LOCATION OF FIRST FLOOR SERVER ROOM.6 PROVIDE AN IN-GRADE HANDHOLE WITH ENGRAVED LID FOR STREET LIGHTING. COORDINATE THE CONNECTIONS TO THE IDAHOPOWER TRANSFORMER. INCLUDE THE OVERCURRENT PROTECTION AND ANY LABELING. REFER TO CITY OF MERIDIANSUPPLEMENT SPECIFICATION, STANDARD DRAWING NO. T2 & T3 FOR ADDITIONAL INSTALLATION REQUIREMENTS.7 PROVIDE THE STREET LIGHT WIRING TO THE POLES PER THE CITY OF MERIDIAN REQUIREMENTS. #8 AWG MINIMUM IN A 2"CONDUIT.8 PROVIDE THE HANDHOLE ADJACENT TO EACH POLE BASE INCLUDING THE ENGRAVED LID PER THE CITY OF MERIDIANREQUIREMENTS.9 PROVIDE THE POLE BASE WITH THE APPROPRIATE BREAKAWAY FITTINGS PER THE CITY OF MERIDIAN REQUIREMENTS.10 PROVIDE THE CITY APPROVED STREET LIGHT TO BE ONE OF THE LISTED LIGHTS WITH COLOR, CONTROL AND SPECIFICATIONSPER THE CITY OF MERIDIAN. THE BASIS OF DESIGN IS A 25' POLE, 54 WATTS, 4K CCT, 208VOLT, LED, WITH INTEGRAL PHOTOCELLCONTROL.PERMIT SET07/16/210.71.71.51.52.53.12.51.92.53.64.14.03.52.92.46.47.35.35.44.03.02.12.24.36.55.75.54.43.83.02.00.92.13.75.05.55.24.13.73.22.31.50.90.82.13.53.95.34.54.03.62.92.01.31.12.23.13.53.63.84.03.42.61.81.11.11.83.03.33.23.23.13.23.02.31.52.33.23.83.93.63.22.82.52.31.91.34.65.95.25.34.13.52.92.31.91.84.07.56.55.65.04.13.52.61.91.41.43.14.85.65.74.84.13.93.02.11.51.01.43.13.75.25.34.43.93.52.72.01.41.01.21.72.63.13.54.14.03.73.22.41.71.21.71.92.32.62.82.93.23.32.72.01.61.12.12.52.62.72.72.52.32.32.21.71.31.20.51.82.83.13.33.43.02.21.81.61.41.00.91.31.33.43.84.14.13.32.31.61.20.90.70.91.70.93.14.65.34.33.82.61.71.10.80.51.12.52.75.05.64.94.03.12.01.30.80.61.53.23.22.82.32.46.06.25.74.23.62.61.71.00.91.93.64.13.63.01.90.95.77.45.74.84.13.22.31.41.32.84.75.54.03.41.90.92.44.85.25.34.03.52.71.91.94.16.05.54.13.31.90.92.64.24.23.73.12.72.22.35.97.65.74.23.42.00.91.03.13.63.32.92.62.22.34.96.75.74.23.32.00.91.43.02.92.82.62.12.03.45.25.64.13.42.00.90.81.92.52.62.62.12.02.84.35.03.83.22.00.91.22.22.62.72.42.02.74.03.63.12.61.70.90.72.02.83.12.92.52.63.53.02.51.91.30.81.83.13.53.43.33.13.12.51.91.41.00.71.23.63.94.34.03.63.02.21.61.20.90.62.84.65.54.44.03.22.21.51.10.92.34.95.65.34.23.72.61.81.41.21.11.00.90.90.90.90.80.90.75.66.85.94.64.13.12.31.91.92.12.01.91.91.91.91.91.61.34.77.65.85.54.53.93.02.62.73.23.53.33.33.33.33.22.51.84.45.25.84.54.23.63.33.43.84.14.14.14.14.03.73.02.42.24.04.24.13.83.63.73.84.35.55.65.75.65.54.93.32.70.92.63.63.63.43.33.63.94.04.95.97.36.55.04.03.42.71.12.62.72.52.32.32.42.53.10.61.31.91.91.81.61.51.41.50.61.31.61.71.81.71.51.31.30.40.81.51.82.12.12.01.81.40.51.32.12.52.52.42.11.50.80.40.92.52.93.13.02.61.80.90.72.53.53.73.73.62.31.20.60.61.73.65.24.43.92.91.70.81.43.65.25.54.13.52.21.20.51.23.47.05.74.83.82.81.60.82.76.86.35.54.13.52.21.20.51.63.65.45.54.53.62.61.52.13.74.23.93.22.41.50.81.22.03.83.42.92.11.41.31.41.42.62.92.41.81.01.91.81.41.52.21.81.42.22.72.31.71.41.51.41.11.73.53.22.72.01.41.11.03.63.93.73.02.21.40.94.25.15.64.23.42.41.40.87.45.95.44.03.42.11.14.66.95.64.53.72.71.50.71.74.35.35.33.93.22.01.02.43.95.34.13.62.51.40.61.03.03.43.73.63.11.80.91.42.52.82.82.82.21.20.61.82.12.01.81.40.8SL1SL1SL1SL1SL1SL1SL1SL1SL1SL1SL1