Loading...
Lighting Spec3Catalog # :Project : Date :Prepared By : LSI Industries Inc. 10000 Alliance Rd. Cincinnati, OH 45242 • www.lsi-industries.com (513) 372-3200 • ©2020 LSI Industries Inc. All Rights Reserved. Specifications subject to change without notice. Page 1/4 Rev. 06/18/20 SPEC.1019.A.0420 Scottsdale VertexTM (SCV) Petroleum Canopy LED Luminaire FEATURES & SPECIFICATIONS Construction • Rugged low-profile die-cast aluminum housing, optical unit, and driver cover. • Below canopy access to optical chamber and driver housing for serviceability. • IP66 rated optical unit protects integral components from dust and water. • Fixtures are finished with LSI’s DuraGrip® polyester powder coat finishing process. The DuraGrip finish withstands extreme weather changes without cracking or peeling. • A single fastener secures access door to driver and key components and provides quick & easy access to the electrical compartment for servicing. • Shipping weight: 15 lbs in carton. Optical System • Proprietary silicone refractor optics provide exceptional coverage and uniformity in Symmetrical or Combination Forward Throw distributions. • State-of-the-art silicone optics deliver industry leading optical control with an integrated gasket to provide an IP66 rated sealed optical chamber in one component. • Silicone optical material does not yellow or crack with age and provides a minimum light transmittance of 93%. • Available in 5000K and 4000K (+/- 275K) color temperatures. • Minimum CRI of 70. Electrical • High-performance driver features over- voltage, under-voltage, short-circuit and over temperature protection. • 0-10V dimming (10% - 100%) standard. • Standard Universal Voltage (120-277 Vac) Input 50/60 Hz or optional High Voltage (347-480 Vac). • L80 Calculated Life: >100k Hours (See Lumen Maintenance on Page 2) • Total harmonic distortion: <20% • Operating temperature: -40°C to +50°C (-40°F to +122°F) when mounted to Steel/ Aluminum surfaces for 10L, 13L, & 15L Lumen Packages, +45°C for 20L Lumen Package, and +40°C for 23L Lumen Package. If mounted to a non-metallic surface, reduce ambient by 5°C. • Power factor: >0.90 • Field replaceable surge protection device meets a minimum Category C Low operation (per ANSI/IEEE C62.41.2). • High-efficacy LEDs are mounted to (4) circuit boards to maximize heat dissipation • Driver components are fully encased in potting material for moisture resistance. Driver complies with FCC standards. Hazardous Locaiton • Designed for lighter than air fuel applications. Product is suitable for Class 1 Division 2 with all lumen packages and distributions only when properly installed per LSI installation instructions. Models with optional controls are not approved for Class 1, Division 2 applications. T5 Temperature Classification – The surface temperature of this product will not rise above 100°C., within a 40°C ambient. Gas Groups A,B,C, and D – Group A: Acetylene / Group B: Hydrogen / Group C: Propane and Ethylene / Group D: Benzene, Butane, Methane & Propane. Installation • Installs in a 12” or 16” deck pan. • Four fasteners are provided with the fixture for using deck, metallic canopy substrates only when classified as suitable for use by installing professional otherwise suitable fasteners should be provided by others. • Unit is designed to quickly retrofit into existing Scottsdale (4”) hole. • Aluminum locking collar and gasket are included and required for complete seal and support of canopy deck. • Retrofit panels are available for existing Encores, Richmond, 2x2 Universal, and more. Warranty • LSI LED Fixtures carry a 5-year warranty or 10-year warranty with registration for petroleum applications only (contact your LSI representative for details). Listings • Listed to UL 1598 and UL 8750. • RoHS Compliant. • Meets Buy American Act requirements. • State of California Title 24 Compliant with IMSBT or ALSC/ALSCS option. • IP66 Rated Optical Unit per IEC 60598. • DesignLights Consortium® (DLC) qualified product. Not all versions of this product may be DLC qualified. Please check the DLC Qualified Products List at www.designlights. org/QPL to confirm which versions are qualified. OVERVIEW Lumen Package 9,000 - 24,000 Wattage Range 66 - 192 Efficacy Range (LPW)119 - 156 Weight lbs(kg)15 (6.8) QUICK LINKS Ordering Guide Performance Photometrics Dimensions LSI Industries Inc. 10000 Alliance Rd. Cincinnati, OH 45242 • www.lsi-industries.com (513) 372-3200 • ©2020 LSI Industries Inc. All Rights Reserved. Specifications subject to change without notice. Page 2/4 Rev. 06/18/20 SPEC.1019.A.0420 Scottsdale Vertex SCV Petroleum ORDERING GUIDE Back to Quick Links FOOTNOTES: 1 - Consult factory for HV with AirLink Synapse Wireless Control System. 2 - IMSBT is field configurable via the LSI app that can be downloaded from your smartphone’s native app store. Accessory Ordering Information Description Order Number Description Order Number Retrofit Panel Kit - EC / ECTA / SCF to SCV, for 16” Deck Panel with larger openings3 673425 26” X 32” Beauty Plate Kit (with 4” Center hole)564160WHT Retrofit Panel Kit - EC / ECTA / SCF to SCV, for 12” Deck Panel4 676011 Junction Box 687461 Retrofit Panel Kit - RECU Richmond to SCV 673426 Kit - Hole Plugs and Sealant (enough for 25 retrofits)1320540 Retrofit Panel Kit - UNV Universal 2x2 to SCV 673427 Rectangular Top Plate Kit (includes top plate and sealant)678291WHT Retrofit 2x2 Cover Panel Blank (no holes)357282 Surface Mount Box 673433 Retrofit RIC Cover Panel Blank (no holes)354702 Retrofit Kit - CRU/CRUS to SCV 687462 26” X 26” Beauty Plate Kit (with 4” Center hole)557193WHT TYPICAL ORDER EXAMPLE:SCV LED 13L SC UNV DIM 50 WHT IMSBT2 Family /Size LEDGen LumenPackage Distribution Voltage Driver ColorTemperature Finish Controls SCV - Petroleum Canopy Luminaire LED 10L - 10000 Lumens 13L - 13000 Lumens 15L - 15000 Lumens 20L - 20000 Lumens 23L - 23000 Lumens 23L - 23000 Lumens SC - Standard Symmetric SCFT - Combination Standard Symmetric and Forward Throw UNV - 120-277V HV - 347-480V DIM - Dims to 10% (0 to 10V dimming) 40 - 4000K 50 - 5000K WHT - White BLK - Black BRZ - Bronze Blank - NONE ALSC - AirLink Synapse Wireless Control System1 ALSCS - AirLink Synapse Wireless Control System with Sensor1 ALBCS1 - AirLink Blue Wireless Motion & Photo Sensor Controller (8-24’ mounting height)5 ALBCS2 - AirLink Blue Wireless Motion & Photo Sensor Controller (25-40’ mounting height)5 IMSBT1 - Integral Bluetooth™ Motion and Photocell Sensor 8 - 24’ mounting height 2, 5 IMSBT2 - Integral Bluetooth™ Motion and Photocell Sensor 25 - 40’ mounting height 2, 5 PERFORMANCE Back to Quick Links *LEDs are frequently updated therefore values are nominal. *Electrical data at 25°C (77°F) ELECTRICAL DATA* Lumen Level 120V 208V 240V 277V 347V 480V 10L 0.55 0.32 0.28 0.24 0.19 0.14 13L 0.70 0.41 0.35 0.30 0.24 0.18 15L 0.86 0.50 0.43 0.37 0.30 0.21 20L 1.09 0.63 0.54 0.47 0.38 0.27 23L (SC)1.27 0.73 0.64 0.55 0.44 0.32 23L (SCFT)1.60 0.92 0.80 0.69 0.55 0.40 SC DISTRIBUTION RECOMMENDED LUMEN MAINTENANCE1 Ambient Temperature C Lumen Multiplier 0 hrs.2 25K hrs.2 50K hrs.2 75K hrs.2 100K hrs.2 25 1.00 0.96 0.92 0.88 0.84 30 1.00 0.96 0.91 0.87 0.83 35 1.00 0.96 0.91 0.87 0.83 40 1.00 0.96 0.91 0.87 0.83 45 1.00 0.96 0.91 0.87 0.82 SCFT DISTRIBUTION RECOMMENDED LUMEN MAINTENANCE1 Ambient Temperature C Lumen Multiplier 0 hrs.2 25K hrs.2 50K hrs.2 75K hrs.2 100K hrs.2 25 1.00 1.00 1.00 0.99 0.99 30 1.00 1.00 0.99 0.99 0.99 35 1.00 1.00 0.99 0.99 0.99 40 1.00 1.00 0.99 0.99 0.99 1. Lumen maintenance values at 25˚C are calculated per TM-21 based on LM-80 data and in-situ luminaire testing. 2. In accordance with IESNA TM-21-11, Projected Values represent interpolated value based on time durations that are within six times (6X) the IESNA LM-80-08 total test duration (in hours) for the device under testing ((DUT) i.e. the packaged LED chip). 3. In accordance with IESNA TM-21-11, Calculated Values represent time durations that exceed six times NA LM-80-08 total test duration (in hours) for the device under testing ((DUT) i.e. the packaged LED chip). DELIVERED LUMENS Drive Current 3000K CCT 4000K CCT 5000K CCT WattageDelivered Lumens Efficiency BUG Ratings Delivered Lumens Efficiency BUG Ratings Delivered Lumens Efficiency BUG Ratings 10L 8723 132 B3-U0-G1 10218 156 B3-U0-G1 10306 156 B3-U0-G1 66 13L 10921 130 B3-U0-G1 12793 153 B3-U0-G1 12933 153 B3-U0-G1 84 15L 12984 125 B3-U0-G1 15209 150 B3-U0-G1 15411 150 B3-U0-G1 103 20L 17145 132 B3-U0-G1 20083 153 B4-U0-G2 20141 155 B4-U0-G2 130 23L 19338 126 B4-U0-G2 22652 149 B4-U0-G2 23150 152 B4-U0-G2 153 23L (SCFT)22778 119 B3-U0-G3 24581 128 B4-U0-G3 24361 127 B3-U0-G3 192 3 - Ideal for 9” to 12” openings. 4 - Ideal for 9” openings. 5 - Not available in HV. LSI Industries Inc. 10000 Alliance Rd. Cincinnati, OH 45242 • www.lsi-industries.com (513) 372-3200 • ©2020 LSI Industries Inc. All Rights Reserved. Specifications subject to change without notice. Page 3/4 Rev. 06/18/20 SPEC.1019.A.0420 Scottsdale Vertex SCV Petroleum Back to Quick Links Luminaire photometry has been conducted by an accredited testing laboratory in accordance with IESNA LM-79-08. As specified by IESNA LM-79-08 the entire luminaire is tested as the source resulting in a luminaire efficiency of 100%. See http://www.lsi-industries.com/products/led-lighting-solutions.aspx for detailed photometric data. PHOTOMETRICS LUMINAIRE DATA Wide Distribution Description 5000 Kelvin, 70 CRI Delivered Lumens 15,410 Watts 103 Efficacy 150 IES Type Type VS - Very Short BUG Rating B3-U0-G1 LUMINAIRE DATA Wide Distribution Description 5000 Kelvin, 70 CRI Delivered Lumens 24,361 Watts 191.5 Efficacy 127 IES Type Type IV - Short BUG Rating B3-U0-G3 Zonal Lumen Summary Zone Lumens %Luminaire Low (0-30)°4101.6 26.6% Medium (30-60)°8386.4 54.4% High (60-80)°2748.8 17.8% Very High (80-90)°173.4 1.1% Uplight (90-180)°0.0 0.0% Total Flux 15410.2 100% Zonal Lumen Summary Zone Lumens %Luminaire Low (0-30)°4368.4 17.9% Medium (30-60)°12592.5 51.7% High (60-80)°6960.6 28.6% Very High (80-90)°439.5 1.8% Uplight (90-180)°0.0 0.0% Total Flux 24361.0 100% 1262 2524 3786 5048 2625 5260 7875 10500 ISOFOOT CANDLE PLOT ISOFOOT CANDLE PLOT POLAR CURVE POLAR CURVE SCV-LED-15L-SC-50 SCV-LED-23L-SCFT-50 15’ Mounting Height / 10’ Grid Spacing 10 FC 5 FC 2 FC 1 FC 15’ Mounting Height / 10’ Grid Spacing 10 FC 5 FC 2 FC 1 FC CANOPY COMPARISON Fixture Fixture Lumens Fixture Watts Lumens/ Watts Canopy/ Watts *Canopy/ Avg.*Transition Area Avg. Canopy Watts/Sq. Ft.QTY SCV-LED-13L-SC-50 18 12,933 84.3 153 1,717 0.39 35.41 3.43 SCV-LED-10L-SC-50 12 10,306 66.1 156 1,942 0.50 34.34 9.58 SCV-LED-23L-SCFT-50 6 24,361 191.5 127 SCV-LED-13L-SC-50 12 12,933 84.3 153 2,161 0.56 39.43 9.70 SCV-LED-23L-SCFT-50 6 24,361 191.5 127 SCV-LED-15L-SC-50 12 15,410 103.0 150 2,385 0.62 44.23 9.80 SCV-LED-23L-SCFT-50 6 24,361 191.5 127 SCV-LED-20L-SC-50 12 20,141 130.3 155 2,713 0.70 53.38 10.03 SCV-LED-23L-SCFT-50 6 24,361 191.5 127 SCV-LED-23L-SC-50 12 23,150 152.5 152 2,979 0.77 59.22 10.16 SCV-LED-23L-SCFT-50 6 24,361 191.5 127 Canopy Layout 1 2 3 4 5 6 (18) 13L Symmetrical Fixtures *Initial foot-candle values at grade. (12) Symmetrical AND (6) Combo FT Fixtures Transition Area50 ft.Canopy Transition Area Canopy50 ft. LSI Industries Inc. 10000 Alliance Rd. Cincinnati, OH 45242 • www.lsi-industries.com (513) 372-3200 • ©2020 LSI Industries Inc. All Rights Reserved. Specifications subject to change without notice. Page 4/4 Rev. 06/18/20 SPEC.1019.A.0420 Scottsdale Vertex SCV Petroleum PRODUCT DIMENSIONS Back to Quick Links CONTROLS AirLink Wireless Lighting Controller The AirLink integrated controller is a California Title 24 compliant lighting controller that provides real-time light monitoring and control with utility-grade power monitoring. It includes a 24V sensor input and power supply to connect a sensor into the outdoor AirLink wireless lighting system. The wireless integrated controller is compatible with this fixture. Click the link below to learn more details about AirLink. https://www.lsi-industries.com/documents/datasheets/airlink-outdoor-specsheet.pdf Integral Bluetooth™ Motion and Photocell Sensor (IMSBT) Slim low profile sensor provides multi-level control based on motion and/or daylight. Sensor controls 0-10 VDC LED drivers and is rated for cold and wet locations (-30° C to 70° C). Two unique PIR lenses are available and used based on fixture mounting height. All control parameters are adjustable via an iOS or Android App capable of storing and transmitting sensor profiles. Click the link below to learn more details about IMSBT. https://www.lsi-industries.com/documents/datasheets/imsbt-specsheet.pdf AirLink™ Blue Wireless Bluetooth Mesh Outdoor Lighting Control System that provides energy savings, code compliance and enhanced safety/security for parking lots and parking garages. Three key components; Bluetooth wireless radio/sensor controller, Time Keeper and an iOS App. Capable of grouping multiple fixtures and sensors as well as scheduling time-based events by zone. Radio/Sensor Controller is factory integrated into Area/Site, Wall Mounted, Parking Garage and Canopy luminaires. Click the link below to learn more details about AirLink Blue. https://www.lsi-airlink.com/airlink-blue/ RETROFIT KITS LSI Industries offers a full line of Retrofit Kits for existing Encore, Richmond, 2x2 Universal and many more older canopy luminaires. Click the link below to see more details on all our Retrofit Kits. https://www.lsi-industries.com/documents/datasheets/scv-petro-retrofit-specsheet.pdf 2.1” (54mm) 15.9” (403mm) 13.5” (343mm) 13.5” (343mm) 2.9” (74mm) 1.0” (25mm) 9.75” (248mm) gasket 3/4” NPS Luminaire Shown with IMSBT Option IMSBT