Loading...
Awning Light FixtureLighting Systems Project Name/Location Part Number Notes# Date Multi-Application 1 HighLINER 2 LED lighting for Indoor & Outdoor HighLINER 2 is designed to replace fluorescent lighting in applications such as coolers, stock rooms, wall washes, soffits, and canopies. HighLINER 2 is easy to install and is a simple solution to save energy and reduce ongoing maintenance costs. Downlighting • Improves walkway and aisle visibility and building aesthetics • Fits easily into new or existing interior and exterior spaces • Saves up to 64% energy compared with typical fluorescent fixtures Co-extruded housing – Eliminates sealing surfaces by using two materials which are formed together—an opaque white for the back and a diffused lens material in the front. Wire channel – Powers lights by running a header wire above the housing to connect multiple luminaires while hiding the power source. Wire cover – Snaps onto the ends of HighLINER 2 to cover wire connections and/or bridge distances between lights. Electrical Input voltage 100-240 VAC, 50-60 Hz Output voltage 24 VDC, Class 2 low voltage Input power System1 Luminaire2 4′ 17 W 14.4 W 1′ 4 W 3.6 W System efficacy 5000 K 105 lm/W 3500 K 93 lm/W Lighting Light output (lumens)3 5000 K 3500 K 4′ 1792 1582 1′ 448 395 Light distribution Linear Color temperatures 5 000 K, 3500 K Color rendering (CRI) 5000 K 80 3500 K >70 Performance Ingress Protection IP66 & IP684 UL location rating Dry, damp, and wet locations Operating temperature -25 °C to 50 °C Life rating 100,000 hours (L70)5 Dimming Optional Motion Sensing (see Cold Series Dimming Control data sheet) Construction Housing Acrylic, impact modified with UV stabilization Body color White Mounting 4′ Mounting clips (3 incl.), Wire nut housing (2 incl.) 1′ Mounting clips (2 incl.), Wire nut housing (2 incl.) Documentation Warranty 5-year limited Agency listings UL, NSF/ANSI 2, ETL, CE, DesignLights Consortium® (DLC), RoHS Files available LM-79, LM-80, IES Specifications 1 For calculating the maximum number of luminaires that can be connected to a power supply, use the LUMINAIRE INPUT POWER. 2 For calculating the maximum number of luminaires that can be connected to the branch circuit, use the SYSTEM INPUT POWER. 3 Tolerance range for optical and electrical data: ±15%. 4 IP66 & IP68 ratings provide protection for extreme outdoor and wet applications (e.g., car wash) or harsh weather exposure. Do not mount in a submerged application. 5 Based on LED component manufacturer data. NSF/ANSI 2 5000 K only 5000 K only 5000 K only 5000 K only 5725 Olivas Park Drive, Ventura, CA 93003 805.676.3200 Fax 805.676.3206 info@SloanLED.com SloanLED.com 2 Ordering Information Product Part Number 4′ HighLINER 2 (5000 K)701912-C1I75 1′ HighLINER 2 (5000 K)701912-L1C1I75 4′ HighLINER 2 (3500 K)701912-35C2I75 1′ HighLINER 2 (3500 K)701912-L135C2I75 © 2016 SloanLED Rev E 2016-10-03 Description Part Number Dimming Controller 701890-PWR Occupancy Sensor, Standard2 400661 Occupancy Sensor, Wide Angle3 400964 Dimming Description Part Number 100 W 701895-24C Power Supplies1 Description Part Number Mounting Clip 400686 Wire Nut Housing 400860 Accessories (included) 1 Single power supply can drive up to six (6) lights. 2 May require an L-bracket (not included) for mounting. 3 Alternative for 400661. Cat 5 cabling to the sensor not included. Dimensions 4′ – 45.70″ × 2.38″ × 1.12″ 1′ – 11.98″ × 2.38″ × 1.12″ weight = 1.06 lbs (4′), 0.25 lbs (1′) Photometrics Polar Candela Curves 638 478 319 159 Polar Candela Curves 1' HighLINER 24' HighLINER 2 (2) Horizontal Cone(1) Vertical Plane(2) Horizontal Cone(1) Vertical Plane Polar Candela CurvesPolar Candela Curves