11-Discovery Park Ph 2 Sewer PlansHORIZ. SCALE: 1" = 50' VERT. SCALE: 1" = 5'SEWER LINE A (STA 1+15 TO 16+65) 2722 2724 2728 2732 2736 2740 2744 2748 2752 2756 2760 2722 2724 2728 2732 2736 2740 2744 2748 2752 2756 2760 0+80 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00 13+00 14+00 15+00 16+00 16+65 0+80 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00 13+00 14+00 15+00 16+00 16+65 367.46' OF 8" SDR 35 PVC @ 0.442% 114.52' OF 8" SDR 35 PVC @ 0.427% 379.56' OF 8" SDR 35 PVC @ 0.422% 291.86' OF 8" SDR 35 PVC @ 0.423% 342.90' OF 8" SDR 35 PVC @ 0.422% FINISHED GRADE @ PIPE C/L APPROXIMATE EXISTING GRADE @ PIPE C/L FINISHED GRADE @ PIPE C/L APPROXIMATE EXISTING GRADE @ PIPE C/L 78.06' WILLIAMS PIPELINE EASEMENT 22" GAS24" GAS2' MIN. SEPARATION2' MIN. SEPARATION3" W8" W48" SSMH-11+15.00, 0.00RIM: 2743.938" IE IN: 2725.97 (NE)8" IE OUT: 2725.87 (W)48" SSMH-24+86.45, 0.00RIM: 2743.898" IE IN: 2727.69 (E)8" IE OUT: 2727.59 (SW)48" SSMH-36+04.97, 0.00RIM: 2744.218" IE IN: 2728.28 (E)8" IE IN: 2728.28 (N)8" IE OUT: 2728.18 (W)4" IE IN: 2729.01 (S)48_ SSMH-49+88.53, 0.00RIM: 2746.638" IE IN: 2729.98 (SE)8" IE OUT: 2729.88 (W)48" SSMH-512+84.39, 0.00RIM: 2748.028" IE IN: 2731.31 (NE)8" IE OUT: 2731.21 (NW)48" SSMH-616+31.29, 0.00RIM: 2749.138" IE IN: 2732.86 (N)8" IE OUT: 2732.76 (SW)VANVANVANVANV A NSTOPSTOP ST O P STOP1+00 2+003+004+005+00 6+00 7+00 8+00 9+00 1 0 + 0 0 1 1 + 0 0 1 2 + 0 0 13+0 0 14+0 0 15+0 0 16+0 0 17+0048" SSMH-1 1+15.00, 0.00 RIM: 2743.93 8" IE IN: 2725.97 (NE) 8" IE OUT: 2725.87 (W) 48" SSMH-2 4+86.45, 0.00 RIM: 2743.89 8" IE IN: 2727.69 (E) 8" IE OUT: 2727.59 (SW)367.46' OF 8" SDR 35 PVC @ 0.442 % 48" SSMH-3 6+04.97, 0.00 RIM: 2744.21 8" IE IN: 2728.28 (E) 8" IE IN: 2728.28 (N) 8" IE OUT: 2728.18 (W) 4" IE IN: 2728.61 (S) 114.52' OF 8" SDR 35 PVC @ 0.427% 48_ SSMH-4 9+88.53, 0.00 RIM: 2746.63 8" IE IN: 2729.98 (SE) 8" IE OUT: 2729.88 (W) 379.56' OF 8" SDR 35 PVC @ 0.422% 48" SSMH-5 12+84.39, 0.00 RIM: 2748.02 8" IE IN: 2731.31 (NE) 8" IE OUT: 2731.21 (NW) 2 9 1 . 8 6 ' O F 8 " S D R 3 5 P V C @ 0 . 4 2 3 % 48" SSMH-6 16+31.29, 0.00 RIM: 2749.13 8" IE IN: 2732.86 (N) 8" IE OUT: 2732.76 (SW) 342.90' OF 8" SDR 35 PVC @ 0.422% 299.78' OF 8" SDR 35 PVC @ 0.426% 342.9 0' O F 8" S D R 3 5 P V C @ 0. 4 2 2 % N: 84359.17 E: 461052.46 8" IE: 2727.03 4" IE: 2727.69 N: 84413.24 E: 460968.22 4" IE: 2739.36 31.41 LF 4" @ 2% N: 84416.87 E: 460999.63 4" IE: 2738.66 78.23 LF 4" @ 15.8% N: 84131.54 E: 461351.41 4" IE: 2741.59 SEE PLUMBING FOR CONTINUATION 5.49 LF 4" @ 2%83.71 LF 4 " @ 2%80.00 LF 4" @ 2%80.00 LF 4" @ 2%82.00 LF 4" @ 9.76%N: 84136.56 E: 461353.63 4" IE: 2741.48 N: 84208.79 E: 461311.32 4" IE: 2739.81 N: 84287.40 E: 461296.51 4" IE: 2738.21 N: 84366.02 E: 461281.70 4" IE: 2736.61 13+74.83 8" IE: 2731.68 14+52.89 8" IE: 2732.01 13+95.64 EG: 2748.88 22" GAS TOP: 2745.55± 14+16.46 EG: 2748.62 24" GAS TOP: 2743.12± 4+75.68 9+43.21 17+33.42 N: 84416.86 E: 460968.21 4" IE: 2739.29 3.62 LF 4" @ 2%6213 N. Cloverdale Rd.Suite 125Boise, Idaho 83704t.208.846.8955f.208.846.8956c.208.867.3954ross@ericksoncivil.comericksoncivilPROFESSIO N AL E OHADIFOETA T S E R IC K SONKSSO R 1 0 8 1 3 NGIN E E RRE G I STERE D DATENO.REVISIONPREPARED BY:PROJECT MANAGER:JOB NUMBER:PH: (208) 846-8955FAX:(208) 846-8956DRAWN BY:ERICKSON CIVIL, INC.-RKESHEET NUMBER:SHEET TITLE:DATE:6-22-21 IDB19075OWNER:PROJECT TITLE:DISCOVERY PARK PHASE 2MERIDIAN, IDCITY OF MERIDIAN---Plans Are Accepted For PublicStreet Construction--ORIGINAL SIGNED PLAN SET ON FILE AT ERICKSON CIVIL, INC.CZC SUBMITTAL (PRELIMINARY NOT FOR CONSTRUCTION)APPROVED FORCONSTRUCTIONIDAHO--ORIGINAL SIGNED PLAN SET ON FILE AT ERICKSON CIVIL, INC.6-22-21 C.UT.2 FEET 0 50 100 SEWER LINE A (STA 1+15 TO 16+65)SEE SHEET C.UT.3 SEWER LI NE A SEWER LINE A S EW E R L I N E A SEW E R LI N E ASEWER LINE BSEE SHEET C.UT.4 139° 10 1 °99°79°136° 105° 127° 15.75'129.54'RESTROOM / CONCESSIONS FINISHED FLOOR EL: 2748.13 WATER SEE SHEET C.UT.1 WATER SEE SHEET C.UT.1 WATER SEE SHEET C.UT.1 WATER SEE SHEET C.UT.1 WATER SEE SHEET C.UT.1 WATER SEE SHEET C.UT.178.06' S T E E L CASI N G W/8" S E W E R 1.MAINTAIN 18" OF VERTICAL SEPARATION BETWEEN WATER LINE AND NON-POTABLE LINE. SEE WATER NOTES 2 & 3 ON SHEET C1.1 AND DETAIL 1/C.UT.4. 2.TRAFFIC RATED CLEANOUT PER ISPWC SD-506A WITH CONCRETE COLLAR. (NO CONCRETE COLLAR WHEN CLEANOUT IS LOCATED IN PORTLAND CEMENT CONCRETE AREA) 3.SEWER SERVICE - 4" DIAMETER TYPE "B" PER ISPWC SD-511. 4.POTHOLE EXISTING GAS LINE AND DETERMINE EXACT HORIZONTAL AND BOTTOM OF PIPE ELEVATION PRIOR TO START OF CONSTRUCTION. COORDINATE POTHOLING WITH WILLIAMS PIPE LINE. 5.INSTALL 78.06 LF OF STEEL CASING, CARRIER PIPE, PLASTIC SKIDS, WATER TIGHT BOOTS, AND APPURTENANT MATERIALS AS PER CITY OF MERIDIAN STD. DWG. SW1 & SW2 AND THE CURRENT EDITION OF THE WILLIAMS DEVELOPER'S HANDBOOK. 1 1.ALL WORK, INCLUDING TRENCHING AND BACKFILL WITHIN THE WILLIAMS PIPE LINE EASEMENT SHALL BE COMPETED IN ACCORDANCE WITH THE "WILLIAMS DEVELOPER'S HANDBOOK". 2.WITHIN THE WILLIAMS PIPELINE EASEMENT TRENCH BACKFILL MATERIAL FROM THE TOP OF PIPE BEDDING TO SUBGRADE SHALL BE TYPE-1 BEDDING CHIPS PER ISPWC SECTION 305. 3.SEWER SERVICES SHALL BE 4" DIAMETER TYPE "B" PER ISPWC SD-511. 4.8" GRAVITY SEWER MAIN SHALL BE PVC SDR 35, ASTM D3034 PER THE CITY OF MERIDIAN STANDARDS. 5.ADDITIONAL FITTINGS MAY BE REQUIRED FROM THOSE SHOWN ON THE PLANS - IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ALL NECESSARY FITTINGS REQUIRED TO CONSTRUCT THE PROJECT AND INCLUDE ALL WORK AND MATERIALS IN THE PROJECT BID - NO SEPARATE PAYMENT SHALL BE MADE. 6.ALL SEWER MANHOLES (SSMH) SHALL BE 48" DIAMETER AS INDICATED ON THE PLANS, AND BE PROVIDED AN INSTALLED IN ACCORDANCE WITH THE CITY OF MERIDIAN STANDARDS AND SPECIFICATIONS. 7.CONTRACTOR SHALL ASSESS THE PROJECT SCOPE OF WORK AND ALL EXISTING CONDITIONS PRIOR TO BID, AND INCLUDE ALL WORK (INCLUDING SURFACE RESTORATION) IN THE BID. 8.PROVIDE ALL TEMPORARY IRRIGATION DITCHES AND PIPES AS REQUIRED TO COMPLETE THE NEW IMPROVEMENTS. ALL EXISTING DITCHES SHALL HAVE TEMPORARY REROUTING PROVISIONS SUCH THAT THE FLOW OF IRRIGATION WATER, AND DRAINAGE OF SURFACE WATER ACROSS THE SITE REMAIN UNINTERRUPTED THROUGHOUT THE DURATION OF CONSTRUCTION. 9.SEE "RD" SHEETS FOR ROADWAY IMPROVEMENT PLANS. 10.SEE "GI" SHEETS FOR GRAVITY IRRIGATION IMPROVEMENT PLANS. 11.RETAIN & PROTECT ALL EXISTING UNDERGROUND UTILITIES - PROVIDE TEMPORARY SHORING AND SUPPORT AS NEEDED TO RETAIN AND PROTECT WITHOUT DISRUPTION - NO SEPARATE PAYMENT SHALL BE MADE. 12.ALL WORK, INCLUDING TRENCHING AND BACKFILL WITHIN THE WILLIAMS PIPE LINE EASEMENT SHALL BE COMPETED IN ACCORDANCE WITH THE "WILLIAMS DEVELOPER'S HANDBOOK". MATERIAL FOR TRENCH BACKFILL FROM THE TOP OF PIPE BEDDING TO SUBGRADE SHALL BE TYPE-1 BEDDING CHIPS PER ISPWC SECTION 305. 13.ALL SURFACE RESTORATION INCLUDING BUT NOT LIMITED TO ASPHALT PAVEMENT, CONCRETE PAVEMENT, SIDEWALK, AND CURB AND GUTTER ARE INCIDENTAL TO UTILITY WORK. CONTRACTOR SHALL ASSESS JOB CONDITIONS, AND SCOPE OF WORK, AND INCLUDE ALL SURFACE RESTORATION AS REQUIRED TO COMPLETE THE WORK IN THE BID - NO SEPARATE PAYMENT SHALL BE MADE. 14.PLUMBING CONTRACTOR SHALL PROVIDE TERMINATIONS FROM THE SITE UTILITY STUBS SHOWN, AND MAKE CONNECTIONS TO BUILDING. 1 1 1 1 RETAIN & PROTECT EXISTING WILLIAMS GAS PIPES - PROVIDE WILLIAMS PIPELINE 48-HOURS NOTICE PRIOR TO PERFORMING ANY WORK WITHIN THE WILLIAMS PIPELINE EASEMENT A REPRESENTATIVE FROM WILLIAMS PIPELINE SHALL BE ONSITE AT ALL TIMES WHILE WORK IS BEING PERFORMED WITHIN SAID EASEMENT 75.00'WILLIAMS PIPELINEEASEMENT20.00'35.00'20.00'2 2 2 2 2 3 3 4 5EXISTING MAINTENANCE SHOP FINISHED FLOOR EL: 2746.46 5 61.00' ROW 76.50' ROW 8" SEWER BY OTHERS 138° REMOVE EXISTING CLEANOUT CONNECT TO EXISTING 8" PVC SEWER 1 1 2 FIELD LOCATE EXISTING SEWER STUB AND CONNECT SHOP TO NEW SEWER SERVICE 1 SEWER LINE A STA 16+65 TO 25+03.06 2722 2724 2728 2732 2736 2740 2744 2748 2752 2756 2760 2764 2722 2724 2728 2732 2736 2740 2744 2748 2752 2756 2760 2764 16+65 17+00 18+00 19+00 20+00 21+00 22+00 23+00 24+00 25+00 25+40 16+65 17+00 18+00 19+00 20+00 21+00 22+00 23+00 24+00 25+00 25+40 299.78' OF 8" SDR 35 PVC @ 0.426% 396.00' OF 8" SDR 35 PVC @ 0.424% 166.01' OF 8" SDR 35 PVC @ 0.425% 25+03.06 8" IE: 2736.73 HORIZ. SCALE: 1" = 50' VERT. SCALE: 1" = 5' FINISHED GRADE @ PIPE C/L APPROXIMATE EXISTING GRADE @ PIPE C/L 6" W12" SD12" SD18" GI48" SSMH-719+35.06, 0.00RIM: 2747.888" IE IN: 2734.24 (N)8" IE IN: 2734.24 (E)8" IE OUT: 2734.14 (S)48" SSMH-823+35.06, 0.00RIM: 2748.848" IE IN: 2736.02 (N)8" IE OUT: 2735.92 (S)15+0016+0017+00 18+00 19+00 20+00 21+00 22+00 23+00 24+00 25+00 48" SSMH-6 16+31.29, 0.00 RIM: 2749.13 8" IE IN: 2732.86 (N) 8" IE OUT: 2732.76 (SW) 48" SSMH-7 19+35.06, 0.00 RIM: 2747.88 8" IE IN: 2734.24 (N) 8" IE IN: 2734.24 (E) 8" IE OUT: 2734.14 (S) 299.78' OF 8" SDR 35 PVC @ 0.426% 48" SSMH-8 23+35.06, 0.00 RIM: 2748.84 8" IE IN: 2736.02 (N) 8" IE OUT: 2735.92 (S) 396.00' OF 8" SDR 35 PVC @ 0.424% 166.01' OF 8" SDR 35 PVC @ 0.425%342.90 ' OF 8 " SDR 3 5 PVC @ 0 .422% 46.00' OF 8" SDR 35 PVC @ 0.438% N: 84727.2210 E: 462227.7857 8" IE: 2734.44 17+33.42 20+46.7820+26.78 1+001+48N: 85127.2210 E: 462180.0005 8" IE: 2736.73 STA: 25+03.06, 0.00 22+35.20 SEWER LINE C STA 1+00 TO 1+48 2728 2732 2736 2740 2744 2748 2752 2756 2760 2728 2732 2736 2740 2744 2748 2752 2756 2760 0+00 1+00 2+00 3+00 0+00 1+00 2+00 3+00 46.00' OF 8" SDR 35 PVC @ 0.438% 1+48.00 8" IE: 2734.44 8" W48" SSMH-719+35.06, 0.00RIM: 2747.888" IE IN: 2734.24 (N)8" IE IN: 2734.24 (E)8" IE OUT: 2734.14 (S)6213 N. Cloverdale Rd.Suite 125Boise, Idaho 83704t.208.846.8955f.208.846.8956c.208.867.3954ross@ericksoncivil.comericksoncivilPROFESSIO N AL E OHADIFOETA T S E R IC K SONKSSO R 1 0 8 1 3 NGIN E E RRE G I STERE D DATENO.REVISIONPREPARED BY:PROJECT MANAGER:JOB NUMBER:PH: (208) 846-8955FAX:(208) 846-8956DRAWN BY:ERICKSON CIVIL, INC.-RKESHEET NUMBER:SHEET TITLE:DATE:6-22-21 IDB19075OWNER:PROJECT TITLE:DISCOVERY PARK PHASE 2MERIDIAN, IDCITY OF MERIDIAN---Plans Are Accepted For PublicStreet Construction--ORIGINAL SIGNED PLAN SET ON FILE AT ERICKSON CIVIL, INC.CZC SUBMITTAL (PRELIMINARY NOT FOR CONSTRUCTION)APPROVED FORCONSTRUCTIONIDAHO--ORIGINAL SIGNED PLAN SET ON FILE AT ERICKSON CIVIL, INC.6-22-21 SEWER LINE A (STA 16+65 TO 25+03.06)C.UT.3 FEET 0 50 100SEE SHEET C.UT.2(SEWER)SEE SHEET C.UT.1(WATER)SEWER LINE ASEWER L INE A90°1 2 7 °5.00'20.00' 12" DIA. STEEL CASING W/8" SEWER PER SW1 & SW2 1.MAINTAIN 18" OF VERTICAL SEPARATION BETWEEN WATER LINE AND NON-POTABLE LINE. SEE WATER NOTES 2 & 3 ON SHEET C1.1 AND DETAIL 1/C.UT.4. 2.T-TYPE CLEANOUT PER STD. DWG. S1. 3.INSTALL 20 LF OF STEEL CASING, CARRIER PIPE, PLASTIC SKIDS, WATER TIGHT BOOTS, AND APPURTENANT MATERIALS AS PER CITY OF MERIDIAN STD. DWG. SW1 & SW2 AND THE CURRENT EDITION OF THE WILLIAMS DEVELOPER'S HANDBOOK. 1 1.ALL WORK WITHIN THE WILLIAMS PIPE LINE EASEMENT SHALL BE PERFORMED IN ACCORDANCE WITH THE CURRENT EDITION OF THE WILLIAMS DEVELOPER'S HANDBOOK. 2.SEWER SERVICES SHALL BE 4" DIAMETER TYPE "B" PER ISPWC SD-511. 3.8" GRAVITY SEWER MAIN SHALL BE PVC SDR 35, ASTM D3034 PER THE CITY OF MERIDIAN STANDARDS. 4.ADDITIONAL FITTINGS MAY BE REQUIRED FROM THOSE SHOWN ON THE PLANS - IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ALL NECESSARY FITTINGS REQUIRED TO CONSTRUCT THE PROJECT AND INCLUDE ALL WORK AND MATERIALS IN THE PROJECT BID - NO SEPARATE PAYMENT SHALL BE MADE. 5.ALL SEWER MANHOLES (SSMH) SHALL BE 48" DIAMETER AS INDICATED ON THE PLANS, AND BE PROVIDED AN INSTALLED IN ACCORDANCE WITH THE CITY OF MERIDIAN STANDARDS AND SPECIFICATIONS. 6.CONTRACTOR SHALL ASSESS THE PROJECT SCOPE OF WORK AND ALL EXISTING CONDITIONS PRIOR TO BID, AND INCLUDE ALL WORK (INCLUDING SURFACE RESTORATION) IN THE BID. 7.PROVIDE ALL TEMPORARY IRRIGATION DITCHES AND PIPES AS REQUIRED TO COMPLETE THE NEW IMPROVEMENTS. ALL EXISTING DITCHES SHALL HAVE TEMPORARY REROUTING PROVISIONS SUCH THAT THE FLOW OF IRRIGATION WATER, AND DRAINAGE OF SURFACE WATER ACROSS THE SITE REMAIN UNINTERRUPTED THROUGHOUT THE DURATION OF CONSTRUCTION. 8.SEE "RD" SHEETS FOR ROADWAY IMPROVEMENT PLANS. 9.SEE "GI" SHEETS FOR GRAVITY IRRIGATION IMPROVEMENT PLANS. 10.RETAIN & PROTECT ALL EXISTING UNDERGROUND UTILITIES - PROVIDE TEMPORARY SHORING AND SUPPORT AS NEEDED TO RETAIN AND PROTECT WITHOUT DISRUPTION - NO SEPARATE PAYMENT SHALL BE MADE. 11.ALL WORK, INCLUDING TRENCHING AND BACKFILL WITHIN THE WILLIAMS PIPE LINE EASEMENT SHALL BE COMPETED IN ACCORDANCE WITH THE "WILLIAMS DEVELOPER'S HANDBOOK". MATERIAL FOR TRENCH BACKFILL FROM THE TOP OF PIPE BEDDING TO SUBGRADE SHALL BE TYPE-1 BEDDING CHIPS PER ISPWC SECTION 305. 12.ALL SURFACE RESTORATION INCLUDING BUT NOT LIMITED TO ASPHALT PAVEMENT, CONCRETE PAVEMENT, SIDEWALK, AND CURB AND GUTTER ARE INCIDENTAL TO UTILITY WORK. CONTRACTOR SHALL ASSESS JOB CONDITIONS, AND SCOPE OF WORK, AND INCLUDE ALL SURFACE RESTORATION AS REQUIRED TO COMPLETE THE WORK IN THE BID - NO SEPARATE PAYMENT SHALL BE MADE. 13.PLUMBING CONTRACTOR SHALL PROVIDE TERMINATIONS FROM THE SITE UTILITY STUBS SHOWN, AND MAKE CONNECTIONS TO BUILDING. 1 DISCOVERY PARK PHASE 1 WATER SEE SHEET C.UT.1 2 3 MERIDIAN RURAL FIRE 9 4 ° 1 7 6 ° 180° 1 1 2 15.64' - VARIES(10' MIN.)2 3 2 SEWER LINE C 15.00'65.00' ROWROW VARIESSEWER LINE C (STA 1+00 TO 1+48) SEWER LINE B STA 1+00 TO 5+58.44 2722 2724 2728 2732 2736 2740 2744 2748 2752 2756 2760 2764 2722 2724 2728 2732 2736 2740 2744 2748 2752 2756 2760 2764 0+80 1+00 2+00 3+00 4+00 5+00 5+90 0+80 1+00 2+00 3+00 4+00 5+00 5+90 96.16' OF 8" SDR 35 PVC @ 1.020% 259.50' OF 8" SDR 35 P V C @ 0 . 9 6 0 % HORIZ. SCALE: 1" = 50' VERT. SCALE: 1" = 5' FINISHED GRADE @ PIPE C/L APPROXIMATE EXISTING GRADE @ PIPE C/L 22" GAS24" GAS2' MIN. SEPARATION2' MIN. SEPARATION75.13' WILLIAMS PIPELINE EASEMENT 15" GI90.81' OF 8" SDR 35 PVC @ 1.905% EXISTING 8" SEWER @ 2.36% (FROM EXISTING RESTROOMS)48" SSMH-31+00.00, 0.00 (LINE B)6+04.97, 0.00 (LINE A)RIM: 2744.218" IE IN: 2728.28 (E)8" IE IN: 2728.28 (N)8" IE OUT: 2728.18 (W)4" IE IN: 2730.74 (S)SSMH-103+63.49, 0.00RIM: 2743.318" IE IN: 2730.87 (NE)8" IE OUT: 2730.77 (S)SSMH-114+63.64, 0.00RIM: 2744.028" IE IN: 2731.95 (NE)8" IE OUT: 2731.85 (SW)SSMH-12 (EXISTING)5+58.44, 0.00RIM: 2743.558" IE OUT: 2733.68 (SW)8" IE IN: 2733.78 (E)VAN VAN FIN I S H ST A R T 1 2 VANVAN1+00 2+00 3+00 4+0 0 5+ 0 0 SSMH-10 3+63.49, 0.00 RIM: 2743.31 8" IE IN: 2730.87 (NE) 8" IE OUT: 2730.77 (S) 259.50' OF 8" SDR 35 PVC @ 0.960% SSMH-12 (EXISTING) 5+58.44, 0.00 RIM: 2743.55 8" IE IN: 2733.78 (E) 8" IE OUT: 2733.68 (SW) 96.16' OF 8" SDR 35 PVC @ 1.020% 48" SSMH-3 1+00.00 OFF: 0.00 (LINE B) 6+04.97, 0.00 (LINE A) RIM: 2744.21 8" IE IN: 2728.28 (E) 8" IE IN: 2728.28 (N) 8" IE OUT: 2728.18 (W) 4" IE IN: 2729.01 (S) 8.75± LF 4" @ 2% MIN. 4+82.20 5+57.33 5+02.23 EG: 2743.47 22" GAS IE: 2740.72± 5+22.27 EG: 2743.43 24" GAS TOP: 2738.26± 4+75.68 SSMH-11 4+63.64, 0.00 RIM: 2744.02 8" IE IN: 2731.95 (NE) 8" IE OUT: 2731.85 (SW) 21.27± LF 4" @ 2% MIN.6213 N. Cloverdale Rd.Suite 125Boise, Idaho 83704t.208.846.8955f.208.846.8956c.208.867.3954ross@ericksoncivil.comericksoncivilPROFESSIO N AL E OHADIFOETA T S E R IC K SONKSSO R 1 0 8 1 3 NGIN E E RRE G I STERE D DATENO.REVISIONPREPARED BY:PROJECT MANAGER:JOB NUMBER:PH: (208) 846-8955FAX:(208) 846-8956DRAWN BY:ERICKSON CIVIL, INC.-RKESHEET NUMBER:SHEET TITLE:DATE:6-22-21 IDB19075OWNER:PROJECT TITLE:DISCOVERY PARK PHASE 2MERIDIAN, IDCITY OF MERIDIAN---Plans Are Accepted For PublicStreet Construction--ORIGINAL SIGNED PLAN SET ON FILE AT ERICKSON CIVIL, INC.CZC SUBMITTAL (PRELIMINARY NOT FOR CONSTRUCTION)APPROVED FORCONSTRUCTIONIDAHO--ORIGINAL SIGNED PLAN SET ON FILE AT ERICKSON CIVIL, INC.6-22-21 SEWER LINE B (STA 1+00 TO 5+58.44)C.UT.4 FEET 0 50 100SEWER LINE AS E W E R L I N E A SEWER LINE B SE W E R L I N E BSEE SHEET C.UT.2SEE SHEET C.UT.2 87 . 0 9 ' O F 1 2 " D I A . S T E E L C A S I N G W / 8 " S E W E R81°79 °101°DISCOVERY PARK PHASE 1 1 1.MAINTAIN 18" OF VERTICAL SEPARATION BETWEEN WATER LINE AND NON-POTABLE LINE. SEE WATER NOTES 2 & 3 ON SHEET C1.1 AND DETAIL 1/C.UT.4. 2.POTHOLE EXISTING GAS LINE AND DETERMINE EXACT HORIZONTAL AND BOTTOM OF PIPE ELEVATION PRIOR TO START OF CONSTRUCTION. COORDINATE POTHOLING WITH WILLIAMS PIPE LINE. 3.INSTALL 87.09 LF OF STEEL CASING, CARRIER PIPE, PLASTIC SKIDS, WATER TIGHT BOOTS, AND APPURTENANT MATERIALS AS PER CITY OF MERIDIAN STD. DWG. SW1 & SW2 AND THE CURRENT EDITION OF THE WILLIAMS DEVELOPER'S HANDBOOK. 4.TRAFFIC RATED CLEANOUT PER ISPWC SD-506A WITH CONCRETE COLLAR. 5.FIELD LOCATE AND CONNECT TO EXISTING 4" SEWER. 6.FIELD LOCATE AND CONNECT TO EXISTING 6" SEWER. 7.SAWCUT AT EXISTING JOINTS AND REMOVE EXISTING CONCRETE AS NEEDED FOR SEWER SERVICE CONNECTIONS. PROVIDE CONCRETE SURFACE RESTORATION TO MATCH EXISTING CONCRETE SURFACE TEXTURE AND JOINT PATTERN PER ISPWC SD-709. 8.CUT AND CAP EXISTING 4" SEWER AT TANK. 9.REMOVE EXISTING SEWER AND CLEANOUT. 10.ADJUST TANK FRAMES AND COVER TO MATCH FINISHED GRADE ELEVATION AND SLOPE. 11.RETAIN & PROTECT EXISTING CONCRETE - DAMAGED, OR CRACKED CONCRETE SHALL BE REPLACED AT CONTRACTOR'S EXPENSE. 1 1.ALL WORK WITHIN THE WILLIAMS PIPE LINE EASEMENT SHALL BE PERFORMED IN ACCORDANCE WITH THE CURRENT EDITION OF THE WILLIAMS DEVELOPER'S HANDBOOK. 2.SEWER SERVICES SHALL BE 4" DIAMETER TYPE "B" PER ISPWC SD-511. 3.8" GRAVITY SEWER MAIN SHALL BE PVC SDR 35, ASTM D3034 PER THE CITY OF MERIDIAN STANDARDS. 4.ADDITIONAL FITTINGS MAY BE REQUIRED FROM THOSE SHOWN ON THE PLANS - IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ALL NECESSARY FITTINGS REQUIRED TO CONSTRUCT THE PROJECT AND INCLUDE ALL WORK AND MATERIALS IN THE PROJECT BID - NO SEPARATE PAYMENT SHALL BE MADE. 5.ALL SEWER MANHOLES (SSMH) SHALL BE 48" DIAMETER AS INDICATED ON THE PLANS, AND BE PROVIDED AN INSTALLED IN ACCORDANCE WITH THE CITY OF MERIDIAN STANDARDS AND SPECIFICATIONS. 6.CONTRACTOR SHALL ASSESS THE PROJECT SCOPE OF WORK AND ALL EXISTING CONDITIONS PRIOR TO BID, AND INCLUDE ALL WORK (INCLUDING SURFACE RESTORATION) IN THE BID. 7.PROVIDE ALL TEMPORARY IRRIGATION DITCHES AND PIPES AS REQUIRED TO COMPLETE THE NEW IMPROVEMENTS. ALL EXISTING DITCHES SHALL HAVE TEMPORARY REROUTING PROVISIONS SUCH THAT THE FLOW OF IRRIGATION WATER, AND DRAINAGE OF SURFACE WATER ACROSS THE SITE REMAIN UNINTERRUPTED THROUGHOUT THE DURATION OF CONSTRUCTION. 8.SEE "RD" SHEETS FOR ROADWAY IMPROVEMENT PLANS. 9.SEE "GI" SHEETS FOR GRAVITY IRRIGATION IMPROVEMENT PLANS. 10.RETAIN & PROTECT ALL EXISTING UNDERGROUND UTILITIES - PROVIDE TEMPORARY SHORING AND SUPPORT AS NEEDED TO RETAIN AND PROTECT WITHOUT DISRUPTION - NO SEPARATE PAYMENT SHALL BE MADE. 11.ALL WORK, INCLUDING TRENCHING AND BACKFILL WITHIN THE WILLIAMS PIPE LINE EASEMENT SHALL BE COMPETED IN ACCORDANCE WITH THE "WILLIAMS DEVELOPER'S HANDBOOK". MATERIAL FOR TRENCH BACKFILL FROM THE TOP OF PIPE BEDDING TO SUBGRADE SHALL BE TYPE-1 BEDDING CHIPS PER ISPWC SECTION 305. 12.ALL SURFACE RESTORATION INCLUDING BUT NOT LIMITED TO ASPHALT PAVEMENT, CONCRETE PAVEMENT, SIDEWALK, AND CURB AND GUTTER ARE INCIDENTAL TO UTILITY WORK. CONTRACTOR SHALL ASSESS JOB CONDITIONS, AND SCOPE OF WORK, AND INCLUDE ALL SURFACE RESTORATION AS REQUIRED TO COMPLETE THE WORK IN THE BID - NO SEPARATE PAYMENT SHALL BE MADE. 13.PLUMBING CONTRACTOR SHALL PROVIDE TERMINATIONS FROM THE SITE UTILITY STUBS SHOWN, AND MAKE CONNECTIONS TO BUILDING. RETAIN & PROTECT EXISTING WILLIAMS GAS PIPES - PROVIDE WILLIAMS PIPELINE 48-HOURS NOTICE PRIOR TO PERFORMING ANY WORK WITHIN THE WILLIAMS PIPELINE EASEMENT A REPRESENTATIVE FROM WILLIAMS PIPELINE SHALL BE ONSITE AT ALL TIMES WHILE WORK IS BEING PERFORMED WITHIN SAID EASEMENT 20 . 0 0 ' 35 . 0 0 ' 20 . 0 0 ' 75 . 0 0 ' WI L L I A M S P I P E L I N E E A S E M E N T 2 3 4 4 4 EXISTING 6" SEWER @ 2.27%± EXISTING 4" SEWER @ 2.0%± EXISTING 4" SEWER @3.07%± 5 5 6 7 89 10 11 11 11 EXISTING PHASE 1 RESTROOM/CONCESSIONS WATER SEE SHEET C.UT.1 WATER SEE SHEET C.UT.1 EXISTING RESTROOM CONNECTION TO SEWERWATER SEE SHEET C.UT.1 3 10 ' 165 °135° 158° TYPICAL WATER & NON POTABLE PIPE CROSSING UT.4 1 NON POTABLE PIPE PROVIDE TEMPORARY PIPE SUPPORT AND SHORING AS REQUIRED WATER LINE 45° BEND 45° BEND 45° BEND 45° BEND AS REQUIRED TO ACHIEVE CLEARANCE AS REQUIRED TO ACHIEVE CLEARANCE USE CHIPS TO BACKFILL TO SPRING LINE OF THE PIPE THAT IS ABOVE THE WATER PIPE (SERVICE OR MAIN)18" MIN10'10' NOTES: 1.WATER SERVICE AND MAIN PIPING SHALL HAVE A MINIMUM OF 48" COVER. 2.CONTRACTOR SHALL CONSTRUCT WATER UNDER NON-POTABLE PIPE IF 18" OF CLEAR VERTICAL SEPARATION CANNOT BE ACHIEVED. 3.CONTRACTOR SHALL ASSESS CROSSINGS PRIOR TO BID AND INCLUDE ALL WORK AND MATERIALS IN THE BID - NO SEPARATE PAYMENT SHALL BE MADE. 4.PROVIDE JOINT RESTRAINTS ON ALL FITTINGS. 5.PROVIDE THRUST BLOCKS PER ISPWC. 6.PROVIDE CASINGS PER CITY OF MERIDIAN STANDARDS WHERE SHOWN.