10-Discovery Park Ph 2 Water PlansVANVANVANVANVANV A NVANSTOPSTOPSTOPSTOP ST O P STOPFINISHSTART12VAN VAN VAN9.98 LF 8" 95.41 LF 8"290.18LF8"11.83 LF 8" 9.07 LF 8" 351.57 LF8" 105.06 LF 8" 48.93 LF 8"68.25 LF 8" 13.11 LF 6" N: 84647.6042 E: 461670.2935 45° BEND N: 84646.4165 E: 461660.3806 45° BEND N: 84560.3320 E: 461619.2358 11.25° BEND 45° BEND N: 84548.8904 E: 461616.2444 8" X 6" TEE GV (W) N: 84552.2585 E: 461602.5372 FIRE HYDRANT 14.11 LF 6" N: 84411.5039 E: 461585.4880 2" METER & SETTER N: 84407.5214 E: 461585.8619 2" METER & SETTER 4.00 LF 4" 33.01 LF 4" 5.00 LF 4" 4" TEE 2" X 4" RED. 2" X 4" RED. 90° BEND 11.25° BEND N: 84439.4905 E: 461565.6316 90° BEND 11.25° BEND 4" X 2" TEE 2" G.V. (N) 220 LF 2" N: 84414.8549 E: 460973.6272 FIIELD LOCATE AND CONNECT SHOP TO NEW WATER SERVICE N: 84259.5669 E: 461655.6212 8" X 6" TEE GV (W) N: 84144.0099 E: 461472.3072 FIRE HYDRANT 216.5 3 L F 6" 8.50 LF 6" 90° BEND N: 84286.9652 E: 461618.7791 2" METER & SETTER N: 84284.2338 E: 461620.0480 2" METER & SETTER 11.25° BEND 40.04 LF 4"4.00 LF 4" 244.4 3 L F 4" 4" TEE 2" X 4" RED. 2" X 4" RED. 90° BEND 11.25° BEND N: 84242.2134 E: 461617.5327 90° BEND 11.25° BEND 11.25° BEND N: 84071.4012 E: 462099.7848 8" X 6" TEE GV (S) N: 84058.2888 E: 462099.7798 FIRE HYDRANT N: 84071.3754 E: 462168.0377 12" X 8" TEE GV (N, S, W)178.61 LF 12"N: 83892.7630 E: 462167.9701 2" BLOWOFF 76.85 LF 12"N: 84715.2154 E: 462194.7812 12"X8" TEE GV (N, S, E) 33.00 LF 8" N: 84715.2029 E: 462227.7812 2" BLOWOFF N: 84375.2697 E: 462171.3071 N: 84408.1937 E: 462172.9153 N: 84694.1868 E: 462194.7732 11.25° BEND EXISTING 8" WATER N: 84494.6678 E: 461096.0792 N: 84347.9164 E: 462116.6663 1" METER & SETTER N: 84120.0795 E: 461405.8060 N: 84125.4877 E: 461364.7060 41.45 LF 4" 21.03 LF 12"169.84 LF 12"N: 84346.7635 E: 462170.6989 N: 84224.7630 E: 462168.0957 N: 84524.8402 E: 462181.8304 12" x 6" TEE 6" GV (W) 33.18 LF 6" N: 84527.3687 E: 462148.7467 FIRE HYDRANT N: 85027.3684 E: 462162.8992 FIRE HYDRANT 235.29 LF 12"116.99 LF 12"32.97 LF 12" 28.51 LF 12"122.03 LF 12"153.39 LF 12"N: 84805.1219 E: 461192.3412 0+00 1+001+06.15 0+11.83 0+69.33 EG: 2747.20 24" GAS IE: 2739.87± 0+48.45 EG: 2746.93 22" GAS IE: 2742.10± 0+27.58 1+002+002+391+12.00 2+13.18 1+38.98 EG: 2750.69 22" GAS IE: 2747.77± 1+65.96 EG: 2750.65 24" GAS IE: 2745.32± N: 84494.6650 E: 461088.9518 N: 84769.8412 E: 461228.3102 N: 84035.4626 E: 461323.9384 N: 84051.0030 E: 461317.7538 N: 84389.5751 E: 461999.0661 N: 84408.2976 E: 462002.2969 N: 84056.6213 E: 461868.8442 1" METER & SETTER 4" X 2" TEE 4" X 2" RED (W) 2" G.V. (N) 374.54 LF 4" 45.00 LF 2"45.00 LF 2" N: 84500.6330 E: 461191.1190 2" TEE 1" X 2" RED (W) 1.5 X 2" RED (E) N: 84505.6409 E: 461186.1201 2" TEE 1.5" X 2" RED (E & W) 113 LF 1"114.28 LF 1"N: 84772.2882 E: 461234.6909 N: 84490.1799 E: 461040.9911 1.5" TEE 1.5" X 1" RED (NW & SW) 1" G.V. (NW & SW)) N: 84492.6912 E: 461034.0765 N: 84413.8530 E: 460955.9328 N: 84056.2250 E: 461840.8918 10.43 LF 1" 19.00 LF 1.5" 150 LF 1.5" N: 84418.6615 E: 461974.3603 N: 84028.8818 E: 461281.8664 N: 84009.4124 E: 461324.6442 41.05 LF 1.5" 5.95 LF 1.5" 69.24 LF 1.5" 1.5" TEE 45.89 LF 1"76.85 LF 12"N: 85027.3684 E: 462162.8992 FIRE HYDRANT 32.00 LF 6"267.86 LF 12"N: 85027.3563 E: 462194.8992 12"X6" TEE GV (W) N: 85295.2189 E: 462195.0005 2" BLOWOFF WATER-GAS CROSSING #2 PROFILE 2736 2740 2744 2748 2752 2756 2760 2736 2738 2740 2742 2744 2746 2748 2750 2752 2754 2756 2758 2760 0+40 0+60 0+80 1+00 1+20 1+40 1+60 1+80 2+00 2+20 2+40 2+60 0+40 0+60 0+80 1+00 1+20 1+40 1+60 1+80 2+00 2+20 2+40 2+6024" GAS2' MIN. SEPARATION22" GAS2' MIN. SEPARATION101.18' WILLIAMS PIPELINE EASEMENT FINISHED GRADE @ PIPE C/L APPROXIMATE EXISTING GRADE @ PIPE C/L WATER-GAS CROSSING #1 PROFILE 2730 2732 2736 2740 2744 2748 2752 2730 2732 2734 2736 2738 2740 2742 2744 2746 2748 2750 2752 2754 -0+80 -0+60 -0+40 -0+20 0+00 0+20 0+40 0+60 0+80 1+00 1+20 1+40 -0+80 -0+60 -0+40 -0+20 0+00 0+20 0+40 0+60 0+80 1+00 1+20 1+40 78.57' WILLIAMS PIPELINE EASEMENT 22" GAS24" GAS2' MIN. SEPARATION2' MIN. SEPARATION15" GI FINISHED GRADE @ PIPE C/L APPROXIMATE EXISTING GRADE @ PIPE C/L 6213 N. Cloverdale Rd.Suite 125Boise, Idaho 83704t.208.846.8955f.208.846.8956c.208.867.3954ross@ericksoncivil.comericksoncivilPROFESSIO N AL E OHADIFOETA T S E R IC K SONKSSO R 1 0 8 1 3 NGIN E E RRE G I STERE D DATENO.REVISIONPREPARED BY:PROJECT MANAGER:JOB NUMBER:PH: (208) 846-8955FAX:(208) 846-8956DRAWN BY:ERICKSON CIVIL, INC.-RKESHEET NUMBER:SHEET TITLE:DATE:6-22-21 IDB19075OWNER:PROJECT TITLE:DISCOVERY PARK PHASE 2MERIDIAN, IDCITY OF MERIDIAN---Plans Are Accepted For PublicStreet Construction--ORIGINAL SIGNED PLAN SET ON FILE AT ERICKSON CIVIL, INC.CZC SUBMITTAL (PRELIMINARY NOT FOR CONSTRUCTION)APPROVED FORCONSTRUCTIONIDAHO--ORIGINAL SIGNED PLAN SET ON FILE AT ERICKSON CIVIL, INC.6-22-21 WATER PLANC.UT.1 FEET 0 50 100 DISCOVERY PARK PHASE 1 PINNACLE SUB.SEE SHEET C.UT.1 R400.00'R400.00' SEE SHEET C.UT.1 12.00'20.00'R600.00'94.32' 12" DIA. STEELCASING W/8" WATERPER SW1 & SW2101.18' 12" DIA. STEELCASING W/8" WATERPER SW1 & SW220.00 LF OF 24" DIA. STEELCASING W/12" WATERPER SW1 & SW2 INSTALLED3' CLR. UNDER GI61.00' ROW SEWER - SEE SHEET C.UT.2 SEWER - SEE SHEET C.UT.2 SEWER - SEE SHEET C.UT.2 SEWER - SEE SHEET C.UT.2 SEWER SEE SHEET C.UT.2 EXISTING CONCESSIONS 1 1.ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH THE CITY OF MERIDIAN CURRENT SUPPLEMENTAL SPECIFICATIONS TO THE ISPWC. 2.SEE THE PROJECT GEOTECHNICAL REPORT AND SHEET C4.2 FOR EARTHWORK REQUIREMENTS. 3.SEE ELECTRICAL PLANS FOR TRANSFORMER LOCATION, SITE ELECTRICAL, AND STREET LIGHTS. 4.ALL TRAFFIC RATED SEWER CLEANOUTS SHALL HAVE CONCRETE COLLARS PER ISPWC SD-506A. 5.CONTRACTOR SHALL PROVIDE CONSTRUCTION STAKING FOR ALL UTILITY INSTALLATION. 6.CONTRACTOR SHALL PROVIDE ALL TRAFFIC CONTROL PLANS AND TRAFFIC CONTROL AS REQUIRED. 7.ALL TRENCHING AND BACKFILL FOR UTILITY INSTALLATION SHALL MEET STRUCTURAL FILL SPECIFICATIONS AS PROVIDED IN THE PROJECT GEOTECHNICAL REPORT. SEE SHEET C1.1 "WATER NOTES" FOR ADDITIONAL REQUIREMENTS. 8.PROVIDE CONCRETE COLLARS FOR ALL VALVES, MANHOLES, AND CLEANOUTS PER THE ISPWC. 9.ALL 4", 8" AND 12" WATER PIPE SHALL BE AWWA C-900 DR18. 10.ALL 2" WATER SERVICE LINES DOWNSTREAM OF THE METER SHALL BE POLYETHYLENE PIPE, 200 PSI, DR7, AWWA/ C906, PER ISPWC DIVISION 400 - PROVIDE ALL TRANSITION FITTINGS. 11.PLUMBING CONTRACTOR SHALL PROVIDE TERMINATIONS FROM THE SITE UTILITY STUBS SHOWN, AND MAKE CONNECTIONS TO BUILDING. 12.ALL SURFACE RESTORATION INCLUDING BUT NOT LIMITED TO ASPHALT PAVEMENT, CONCRETE PAVEMENT, SIDEWALK, AND CURB AND GUTTER ARE INCIDENTAL TO UTILITY WORK. CONTRACTOR SHALL ASSESS JOB CONDITIONS, AND SCOPE OF WORK, AND INCLUDE ALL SURFACE RESTORATION AS REQUIRED TO COMPLETE THE WORK IN THE BID - NO SEPARATE PAYMENT SHALL BE MADE. 13.SEE STORM DRAIN PLAN FOR STORM DRAIN PIPE INVERT ELEVATIONS AT WATER MAIN CROSSING LOCATIONS. AT CROSSING LOCATIONS, WATER MAIN SHALL BE INSTALLED TO PROVIDE VERTICAL SEPARATION BETWEEN THE WATER MAIN AND THE NON-POTABLE MAIN IN ACCORDANCE WITH 1/C.UT.1. CONTRACTOR SHALL INVESTIGATE CROSSING REQUIREMENTS AND INCLUDE ALL WORK IN THE BID - NO SEPARATE PAYMENT SHALL BE MADE. 14.RIM ELEVATIONS SHOWN ARE AT THE CENTER OF THE COVER - COVER SHALL SLOPE TO MATCH SURROUNDING GRADES. 15.THE SITE UTILITY CONTRACTOR SHALL CONSTRUCT THE DOMESTIC WATER SERVICE LINE FROM THE DOWNSTREAM SIDE OF THE METER TO THE BUILDING. 16.ADJUST WATER METER VALVES AND METER TILE LID TO MATCH FINISHED GRADE AND SLOPE. 17.ADDITIONAL FITTINGS MAY BE REQUIRED FROM THOSE SHOWN ON THE PLANS - IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ALL NECESSARY FITTINGS REQUIRED TO CONSTRUCT THE PROJECT AND INCLUDE ALL WORK AND MATERIALS IN THE PROJECT BID - NO SEPARATE PAYMENT SHALL BE MADE. 18.ALL WORK, INCLUDING TRENCHING AND BACKFILL WITHIN THE WILLIAMS PIPE LINE EASEMENT SHALL BE COMPETED IN ACCORDANCE WITH THE "WILLIAMS DEVELOPER'S HANDBOOK". MATERIAL FOR TRENCH BACKFILL FROM THE TOP OF PIPE BEDDING TO SUBGRADE SHALL BE TYPE-1 BEDDING CHIPS PER ISPWC SECTION 305. 19.NO WATER SYSTEM FITTINGS ARE ALLOWED WITHIN THE WILLIAMS PIPELINE EASEMENT. CONTRACTOR SHALL LOWER WATER LINE DEPTH TO PROVIDE A MINIMUM OF 2-FEET CLEAR BETWEEN THE BOTTOM OF THE LOWEST GAS LINE AND THE TOP OF THE WATER MAIN, OR WATER MAIN CASING AS APPLICABLE. ALL WORK SHALL BE INCLUDED IN THE BID, INCLUDING FITTINGS - NO SEPARATE PAYMENT SHALL BE MADE. 20.NO WATER MAIN JOINTS ARE ALLOWED WITHIN 5-FEET OF THE EXTERIOR WALL OF THE WILLIAMS PIPELINE GAS LINES. Notes 1.RETAIN & PROTECT EXISTING SEWER. 2.RETAIN & PROTECT EXISTING WATER. 3.EXISTING OVERHEAD POWER - SEE ELECTRICAL PLANS FOR RELOCATION REQUIREMENTS 4.RETAIN & PROTECT EXISTING TELEPHONE AND FIBER OPTICS - POTHOLE AND DETERMINE THE EXACT HORIZONTAL AND VERTICAL LOCATION OF EXISTING LINES WITHIN THE WORK AREA PRIOR TO START OF CONSTRUCTION. NOTIFY ENGINEER IMMEDIATELY IF EXISTING UTILITIES CONFLICT WITH ANY PLANNED IMPROVEMENTS. 5.MAINTAIN 18" OF VERTICAL SEPARATION BETWEEN WATER LINE AND NON POTABLE LINE. SEE WATER NOTES 2 & 3 ON SHEET C1.1, AND DETAIL 3/C.UT.5. 6.NEW 2" WATER SERVICE, METER, & SETTER PER STD. DWG. W4. 7.2.0" WATER SERVICE STUB - PROVIDE REDUCER/FITTINGS AS REQUIRED - SEE PLUMBING PLANS FOR CONTINUATION. 8.FIELD LOCATE AND CONNECT TO EXISTING 8" WATER. REMOVE EXISTING WATER AND BLOWOFF DOWNSTREAM OF NEW WATER CONNECTION. PROVIDE TYPE-P SURFACE RESTORATION. 9.DRINKING FOUNTAIN WATER SERVICE AND DRAIN - (SEE 3/C.UT.5). DRINKING FOUNTAIN BY OTHERS. 10.1" REDUCED PRESSURE BACK FLOW PREVENTER FOR SITE WATER SUPPLY - (SEE DETAIL 2/C.UT.5). 11.POTHOLE EXISTING GAS LINE AND DETERMINE EXACT BOTTOM OF PIPE ELEVATION PRIOR TO START OF CONSTRUCTION. COORDINATE POTHOLING WITH WILLIAMS PIPE LINE. 12.4.0" WATER SERVICE STUB - PROVIDE REDUCER/FITTINGS AS REQUIRED - SEE PLUMBING PLANS FOR CONTINUATION. 13.CONNECT TO 2" WATER STUB FROM BUILDING. 14.INSTALL STEEL CASING, WATER MAIN, PLASTIC SKIDS, WATER TIGHT BOOTS, AND APPURTENANT MATERIALS AS PER CITY OF MERIDIAN STD. DWG. SW1 & SW2 AND THE CURRENT EDITION OF THE WILLIAMS DEVELOPER'S HANDBOOK. 15.FIRE HYDRANT PER STD. DWGS. W8 & W9. 16.2" BLOW OFF ASSEMBLY PER STD. DWG. W12. 17.INSTALL STEEL CASING, WATER MAIN, PLASTIC SKIDS, WATER TIGHT BOOTS, AND APPURTENANT MATERIALS AS PER CITY OF MERIDIAN STD. DWG. SW1 & SW2. 18.DRINKING FOUNTAIN WATER SUPPLY VALVE BOX - (SEE 3/C.UT.5). LOCATE VALVE BOX IN PLANTER. 19.SINGLE WATER SERVICE PER W1 & W2 WITH 1" METER AND 1" SERVICE LINE SIZE. 20.2" REDUCED PRESSURE BACK FLOW PREVENTER FOR SITE WATER SUPPLY - (SEE DETAIL 2/C.UT.5). 21.FROST FREE YARD HYDRANT - (SEE 4/C.UT.5). 22.SITE WATER SUPPLY - (SEE 1/C.UT.5). 23.1" SITE DRINKING FOUNTAIN SUPPLY FROM BUILDING - SEE PLUMBING PLANS FOR CONTINUATION. 24.1.5" SITE WATER SERVICE SUPPLY FROM BUILDING - SEE PLUMBING PLANS FOR CONTINUATION. Keyed Notes 2 55 5 5 5 5 6 6 6 6 7 8 11 11 RETAIN & PROTECT EXISTING WILLIAMS GAS PIPES - PROVIDE WILLIAMS PIPELINE 48-HOURS NOTICE PRIOR TO PERFORMING ANY WORK WITHIN THE WILLIAMS PIPELINE EASEMENT A REPRESENTATIVE FROM WILLIAMS PIPELINE SHALL BE ONSITE AT ALL TIMES WHILE WORK IS BEING PERFORMED WITHIN SAID EASEMENT75.00'WILLIAMS PIPELINEEASEMENT20.00'35.00'20.00'75.00'WILLIAMS PIPELINEEASEMENT20.00'35.00'20.00'RETAIN & PROTECT EXISTING WILLIAMS GAS PIPES - PROVIDE WILLIAMS PIPELINE 48-HOURS NOTICE PRIOR TO PERFORMING ANY WORK WITHIN THE WILLIAMS PIPELINE EASEMENT A REPRESENTATIVE FROM WILLIAMS PIPELINE SHALL BE ONSITE AT ALL TIMES WHILE WORK IS BEING PERFORMED WITHIN SAID EASEMENT 12 14 17 15 15 15 5 19 10 16 16 16MERIDIAN RURAL FIRE 35.50' (25' MIN) 28.00' (25' MIN) 28.00' (25' MIN) 10.00' 15.00' 15.00' 10.00' 16.80' VARIES (10' MIN) 5 5 5 15.41' VARIES (10' MIN.) 9 SEWER - SEE SHEET C.UT.2 14 SEE WATER-GAS CROSSING #1 PROFILE ON THIS SHEET SEE WATER-GAS CROSSING #2 PROFILE ON THIS SHEET RESTROOM / CONCESSIONS FINISHED FLOOR EL: 2748.13 15 15 18 18 9 18 9 18 9 10 19 20 20 EXISTING MAINTENANCE SHOP FINISHED FLOOR EL: 2746.46 5 5 21 21 21 332 LF 1.5" 338 LF 1.5" 58 LF 1.5" SHELTER #1 SHELTER #2 22 22 22 22 23 24 10 133 LF 1.5" 184 LF 1.5"7.00'5