ACHD Transmittal (A-2021-0112)Applicant name:DANA KAUFFMAN, INSIGHTARCHITECTS Phone:208
Applicant address:2238 BROADWAY AVE, BOISE, ID 83706 Email:Dana@insightarchitects.com
Owner name:LYNN MALLORY, MALLORY HOLDINGS LLC Phone:Fax:
Owner address:
2280 E. COMMERCIAL ST., MERIDIAN, IA
83642 Email:lynn.mallory@rrsc.com
Administrative
Applicant Information
Type of Review Requested
File number:A-2021-0112
Assigned Planner:Cameron Scott
Related Files:
Subject Property Information
Location/street address:711 N TOUCHMARK AVE
Assessor's parcel number(s):R7138500030
Township, range, section:
Agent name (e.g. architect, engineer, developer, representative):DANA KAUFFMAN
Firm name:INSIGHT ARCHITECTS Phone:Fax:
Address:2238 BROADWAY AVE Email:dana@insightarchitects.com
Contact name:DANA KAUFFMAN Phone:208 Fax:
Contact address:2238 BROADWAY AVE Email:Dana@insightarchitects.com
Project/Application Name:Roto Rooter Office - DES, CZC
Description of Work:Single story 3,340 sf. Commercial Office Building with related site work.
Project Description
Planning Division
ADMINISTRATIVE APPLICATION
33 E Broadway Avenue, Suite 102ƔMeridian, Idaho 83642
Phone: (208)884-5533ƔFacsimile: (208) 888-6854ƔWebsite: www.meridaincity.org
1
APPLICATION TYPES
Is this application exempt from fees?:No
Certificate of Zoning Compliance - CZC:CHECKED
Does project have prior approval?:No
Does your project contain new construction and/or modifications to an existing
building or the site?:
Yes
Design Review - DES:CHECKED
ADDRESS VERIFICATION
Address Verification Permit Number:LDAV-2021-0373
TYPE OF USE PROPOSED
Commercial:CHECKED
PUBLIC WORKS INFRASTRUCTURE
Does this project require the extension of public infrastructure?:No
PROPERTY INFORMATION
General Location:South of the intersection of E. Pine and N.
Touchmark Ave.
Current Land Use:Light Industrial
Total Acreage:1.38
Prior Approvals (File Numbers):n/A
ZONING DISTRICT(S)
I-L:CHECKED
PROJECT INFORMATION
Site Plan Date (MM/DD/YYYY):4/12/2021
Landscape Plan Date (MM/DD/YYYY):4/12/2021
Elevations Date (MM/DD/YYYY):4/12/2021
Percentage of Site Devoted to Building:18.9
Percentage of Site Devoted to Landscaping:21.2
Percentage of Site Devoted to Paving:59.9
Who will own and Maintain the Pressurized Irrigation System in this Development:Owner
Irrigation District:Settler's
Primary Irrigation Source:Pressurized
Secondary Irrigation Source:City Water
Square Footage of Landscaped Areas to be Irrigated by City Water Connection:19,943 sf
Proposed Building Height:17 ft.
Existing Floor Area (If Applicable):0
Gross Floor Area Proposed:3,347 sf
Number of Standard Parking Spaces Provided:14
Number of Compact Parking Spaces Provided:0
Number of Employees:9
Application Information
33 E Broadway Avenue, Suite 102ƔMeridian, Idaho 83642
Phone: (208)884-5533ƔFacsimile: (208) 888-6854ƔWebsite: www.meridaincity.org
2
In Reclaimed Water Buffer:No
TIME EXTENSION INFORMATION
Number of months extension:24
APPLICATION DISCLAIMER
I have read and accept the above terms:CHECKED
Your signature:Dana Kauffman
33 E Broadway Avenue, Suite 102ƔMeridian, Idaho 83642
Phone: (208)884-5533ƔFacsimile: (208) 888-6854ƔWebsite: www.meridaincity.org
3
Roto-Rooter Zoning Narrative
May 18, 2021
Site
The site is zoned “I-L” Light Industrial. The proposed use of a plumbing contractor’s office and
warehouse is an allowed use. Adjacent properties are zoned “I-L”. The site area is 1.38 acres.
The required building setbacks are:
o Front/Side/Rear: 0 ft. - Proposed: 10 feet
o Streets: 35 ft. from street R.O.W. - Proposed 66 ft.
o Landscape buffers abutting streets:
Local: 10 ft. - Proposed 10 ft.
Collector: 20 ft. - N/A
A 10-foot landscape buffer is proposed along the north, west, and south property lines.
Maximum Building Height: 50 feet - Proposed 20 ft.
Building Site Area Requirements: None
Building Density Formula: None
The site is vacant. Street improvement have been completed. No new work in the R.O.W. is
proposed.
Street access is existing with a shared access drive with the adjoining property to the north.
All utilities have been installed to the site.
Parking Requirements:
o Office: 1 per 500 gross floor area = 7 required
o Warehouse: 1 per 2,000 sq. ft. of gross floor area = 4 required
o Required parking = 11 - Provided parking = 14
A bicycle rack is proposed at the office entrance.
A concrete walkway connects the front of the office with the public sidewalk along the street.
A fenced-in yard is proposed behind the two new buildings.
A concrete block trash enclosure with painted steel gates encloses the trash and recycle
dumpsters. The proposed location has been approved by Republic Services.
There are recorded CC&R’s.
There is a 45 ft. canal easement along the southern edge of the property. According to the canal
district, paving and landscaping can be installed in the northerly 25 ft. of the easement.
Buildings
The proposed office is a single-story 3,347 sq. ft. steel framed building. Exterior materials
include metal paneling, fiber-cement panels, concrete block, painted steel canopies, and
aluminum storefront doors and windows. Space has been provided for a future 3,033 sq. ft.
addition to the back of the building.
The proposed warehouse is a single-story 8,040 sq. ft. steel-framed building. Exterior materials
include metal paneling, fiber-cement paneling, painted hollow-metal doors and frames, and pre-
finished sectional roll-up doors.