SITE PLAN -1250 W. Ustick6/14/21 FINAL CD'S NP 839612 CM IDL01003 IDL01003 1250 WEST USTICK ROAD MERIDIAN, ID 83646 161 Inverness Drive West 2nd floor Englewood, Colorado 80112 PREPARED FOR: REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: BU NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Tower Owner: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: A&E: at&t 2055 SOUTH STEARMAN DRIVE CHANDLER, AZ 85286 B RAD CENTER CHANGE04/23/21 A 4/07/21 PRELIMINARY CD'S C RAD CENTER CHANGE06/01/21 0 SUBMITTAL CD'S06/03/21 0A 6/14/21 SUBMITTAL CD'S TIM ALEX A N D E RSIGNED, EXPIRES, 28 FEB 2023 SHEET INDEX PROJECT INFORMATION APPROVALS APPROVED BY:INITIALS:DATE: VENDOR: LEASING / LANDLORD: R.F.: ZONING: CONSTRUCTION: POWER / TELCO: PG&E: CODE COMPLIANCE PROJECT DESCRIPTION PROJECT TEAM GENERAL CONTRACTOR NOTES DO NOT SCALE DRAWINGS THESE DRAWINGS ARE FORMATTED TO BE FULL SIZE AT 24" x 36". CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOBSITE AND SHALL IMMEDIATELY NOTIFY THE ARCHITECT/ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR MATERIAL ORDERS OR BE RESPONSIBLE FOR THE SAME. DIRECTIONS FROM AT&T Property Information: Site Name: MERIDIAN RELO 2 Site Number: IDL01003 FA#: 15468575 Site Address: 1250 WEST USTICK ROAD MERIDIAN, ID 83646 A.P.N. Number: R9532190560 Current Use: UNMANNED TELECOMMUNICATIONS SITE Proposed Use: UNMANNED TELECOMMUNICATIONS SITE Jurisdiction: CITY OF MERIDIAN Latitude: ƒƍƎ1 ƒ Longitude: ƒƍƎ:ƒ Ground Elevation: 2,733.7' FT. AMSL DISABLED ACCESS REQUIREMENTS FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION, ACCESSIBILITY ACCESS IS NOT REQUIRED, IN ACCORDANCE WITH CALIFORNIA BUILDING CODE, CODE OF REGULATIONS, TITLE 24, PART 2, VOLUME 1, CHAPTER 11B, DIVISION 2, SECTION 11B-203.5 OCCUPANCY AND CONSTRUCTION TYPE OCCUPANCY : U (UNMANNED) CONSTRUCTION TYPE: V-B AT&T:TITLE SHEET T-1 VICINITY MAP 1. ANCHOR BOLTS WET-SET INTO CONCRETE 2. EXPANSION BOLTS INTO EXISTING CONCRETE 3. HIGH STRENGTH BOLTING 4. WELDING 5. STEEL REINFORCEMENT / REBAR PLACEMENT 6. STEEL MATERIAL VERIFICATION SOILS ENGINEER TO INSPECT DRILLED PIERS SPECIAL INSPECTIONS REV SITE TYPE: MONOPOLE / WIC at&t SITE NUMBER: IDL01003 SITE NAME: MERIDIAN RELO 2 1250 WEST USTICK ROAD MERIDIAN, ID 83646 JURISDICTION: CITY OF MERIDIAN FA#: 15468575 USID: 300903 PACE#: MRUTH044492 USID: 300903 Project: NSB RFDS ID: 4375498 PROJECTS LTE 1C LTE 2C LTE 3C LTE 4C LTE 5C TITLE SHEETT-1 OVERALL SITE PLAN - EXTERIOR EQUIPMENT WICA-1 MONOPOLE NORTH ELEVATIONSA-4.1 A-4.2 EXISTING COMPOUND PLAN - EXTERIOR EQUIPMENT WICA-2 ANTENNA PLAN & DETAILS - MONOPOLEA-3 0A MONOPOLE WEST ELEVATIONS PROPOSED COMPOUND PLAN - EXTERIOR EQUIPMENT WICA-2.1 INTERIOR WIC LAYOUT - INTERIOR EQUIPMENT WICA-2.2 GENERAL NOTESGN-1 GENERAL NOTESGN-2 GENERAL NOTESGN-3 GENERAL NOTESGN-4 GENERAL NOTESGN-5 GENERAL NOTESGN-6 SITE SIGNAGEGN-7 A-5 DETAILS A-5.1 DETAILS S-1 STRUCTURAL PLAN & DETAILS E-1 GENERAL ELECTRICAL/GROUNDING NOTES E-2 UTILITY SITE PLAN E-3 POWER ONE-LINE DIAGRAM E-4 BATTERY DETAILS & SPECIFICATIONS G-1 GROUNDING PLAN G-2 GROUNDING DETAILS G-3 GROUNDING DETAILS G-4 GROUNDING DETAILS ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES. 1.2015 INTERNATIONAL BUILDING CODE (IBC) 2.2015 INTERNATIONAL FIRE CODE (IFC) 3.2015 INTERNATIONAL MECHANICAL CODE (IMC) 4.2015 INTERNATIONAL PLUMBING CODE (IPC) 5.2014 NATIONAL ELECTRICAL CODE (NEC) 6.ICC/ANSI A117.1, CRS 9-5-101, AS AMENDED 7.2015 NFPA 101, LIFE SAFETY CODE 8.2016 NFPA 72, NATIONAL FIRE ALARM CODE 9.2016 NFPA 13, FIRE SPRINKLER CODE Power Agency: IDAHO POWER ph: 1-800-488-6151 Telephone Agency: PENDING ph: PENDING Property Owner: CROWN CASTLE TOWERS 09 LL POST OFFICE BOX 203469 C/O CROWN CASTLE INVESTMENT CORP SOLE HOUSTON, TX 77216-3469 NEW SITE BUILD UNMANNED TELECOMMUNICATIONS FACILITY. 1.BRING POWER / FIBER TO SITE LOCATION 2.ADD AT&T APPROVED WALK IN CABINET (WIC) AND ASSOCIATED INTERIOR EQUIPMENT 3.ADD (1) 30KW AC DIESEL GENERATOR 4.ADD (1) NEW GPS UNIT 5.ADD (3) VFA12-HD-WLL SECTOR MOUNTS ON (E) MONOPOLE 6.ADD (6) ANTENNAS, (2) PER SECTOR 7.ADD (15) RRHs, (5) PER SECTOR 8.ADD (3) DC6 SURGE SUPPRESSORS, (1) PER SECTOR 9.ADD (6) DC TRUNKS 10.ADD (3) FIBER TRUNKS DIRECTIONS FROM AT&T's OFFICE AT 161 INVERNESS DR W, ENGLEWOOD, CO 80112: 1.TAKE I-84 TO EXIT 44. HEAD NORTH ON S MERIDIAN RD 1.9 MILES TURN LEFT ON W USTICK RD 0.8 MILES. SITE IS ON YOUR RIGHT BEHIND HOUSE. SITE S-2 STRUCTURAL PLAN & DETAILS S-3 GENERATOR DETAILS LTE 6C ARCHITECT / ENGINEER: TELCYTE INFRASTRUCTURE SERVICES ADDRESS: 3450 N HIGLEY RD - SUITE 102 CITY, STATE ZIP: MESA, AZ 85215 CONTACT: CHRISTIAN MUELLER EMAIL: cmueller@telcyte.com PH: (720) 244-6013 CONSTRUCTION MANAGER: AT&T MOBILITY CORP. ADDRESS: 161 INVERNESS DRIVE W 2ND FLOOR CITY, STATE ZIP: ENGLEWOOD, CO 80112 CONTACT: REID POST EMAIL: RP836C@ATT.COM PH: (720) 838-4228 RF ENGINEER: AT&T MOBILITY CORP. ADDRESS: 161 INVERNESS DRIVE W 2ND FLOOR CITY, STATE ZIP: ENGLEWOOD, CO 80112 CONTACT: SHAD RYDALCH EMAIL: JR129E@US.ATT.COM PH: (208) 317-0011 APPLICANT / LESSEE: PROJECT MANAGER AT&T MOBILITY CORP. ADDRESS: 161 INVERNESS DRIVE W 2ND FLOOR CITY, STATE ZIP: ENGLEWOOD, CO 80112 CONTACT: JAN ROBINETTE EMAIL: jr103n@att.com PH: (801) 201-4173 TOWER OWNER: CROWN CASTLE ADDRESS: 2055 STEARMAN DR. CITY, STATE ZIP: CHANDLER, AZ 85286 CONTACT: KRISTEN LEONARD EMAIL: Kristen.Leonard@crowncastle.com PH: (412) 952-1614 SURVEY & WIC ATTACHMENT DETAILS ADDED AS ADDENDUM 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 6/14/21 FINAL CD'S NP 839612 CM IDL01003 IDL01003 1250 WEST USTICK ROAD MERIDIAN, ID 83646 161 Inverness Drive West 2nd floor Englewood, Colorado 80112 PREPARED FOR: REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: BU NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Tower Owner: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: A&E: at&t 2055 SOUTH STEARMAN DRIVE CHANDLER, AZ 85286 B RAD CENTER CHANGE04/23/21 A 4/07/21 PRELIMINARY CD'S C RAD CENTER CHANGE06/01/21 0 SUBMITTAL CD'S06/03/21 0A 6/14/21 SUBMITTAL CD'S TIM ALEX A N D E RSIGNED, EXPIRES, 28 FEB 2023 GENERAL NOTES GN-1 GENERAL CONSTRUCTION NOTES: GENERAL CONSTRUCTION 1. FOR THE PURPOSE OF CONSTRUCTION DRAWINGS, THE FOLLOWING DEFINITIONS SHALL APPLY: GENERAL CONTRACTOR: T.B.D. CONTRACTOR: T.B.D. OWNER: AT&T 2. ALL SITE WORK SHALL BE COMPLETED AS INDICATED ON THE DRAWINGS AND AT&T PROJECT SPECIFICATIONS. 3.GENERAL CONTRACTOR SHALL VISIT THE SITE AND SHALL FAMILIARIZE HIMSELF WITH ALL CONDITIONS AFFECTING THE PROPOSED WORK AND SHALL MAKE PROVISIONS. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH ALL CONTRACT DOCUMENTS, FIELD CONDITIONS, DIMENSIONS, AND CONFIRMING THAT THE WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK. 4. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. GENERAL CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS, AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF WORK. 5.ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES, AND APPLICABLE REGULATIONS. 6. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES, AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 7. PLANS ARE NOT TO BE SCALED. THESE PLANS ARE INTENDED TO BE A DIAGRAMMATIC OUTLINE ONLY UNLESS OTHERWISE NOTED. DIMENSIONS SHOWN ARE TO FINISH SURFACES UNLESS OTHERWISE NOTED. SPACING BETWEEN EQUIPMENT IS THE MINIMUM REQUIRED CLEARANCE. THEREFORE, IT IS CRITICAL TO FIELD VERIFY DIMENSIONS, SHOULD THERE BE ANY QUESTIONS REGARDING THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A CLARIFICATION FROM THE ENGINEER PRIOR TO PROCEEDING WITH THE WORK. DETAILS ARE INTENDED TO SHOW DESIGN INTENT. MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF WORK AND PREPARED BY THE ENGINEER PRIOR TO PROCEEDING WITH WORK. 8. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 9. IF THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION SPACE FOR APPROVAL BY THE ENGINEER PRIOR TO PROCEEDING. 10. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF WORK AREA, ADJACENT AREAS AND BUILDING OCCUPANTS THAT ARE LIKELY TO BE AFFECTED BY THE WORK UNDER THIS CONTRACT. WORK SHALL CONFIRM TO ALL OSHA REQUIREMENTS AND THE LOCAL JURISDICTION. 11. GENERAL CONTRACTOR SHALL COORDINATE WORK AND SCHEDULE WORK ACTIVITIES WITH OTHER DISCIPLINES. 12. ERECTION SHALL BE DONE IN A WORKMANLIKE MANNER BY COMPETENT EXPERIENCED WORKMAN IN ACCORDANCE WITH APPLICABLE CODES AND THE BEST ACCEPTED PRACTICE. ALL MEMBERS SHALL BE LAID PLUMB AND TRUE AS INDICATED ON THE DRAWINGS. 13. SEAL PENETRATIONS THROUGH FIRE RATED AREAS WITH UL LISTED MATERIALS APPROVED BY LOCAL JURISDICTION. CONTRACTOR SHALL KEEP AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DEBRIS. 14. WORK PREVIOUSLY COMPLETED IS REPRESENTED BY LIGHT SHADED LINES AND NOTES. THE SCOPE OF WORK FOR THIS PROJECT IS REPRESENTED BY DARK SHADED LINES AND NOTES. CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR OF ANY EXISTING CONDITIONS THAT DEVIATE FROM THE DRAWINGS PRIOR TO BEGINNING CONSTRUCTION. 15. CONTRACTOR SHALL PROVIDE WRITTEN NOTICE TO THE CONSTRUCTION MANAGER 48 HOURS PRIOR TO COMMENCEMENT OF WORK. 16. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF THE OWNER. 17. THE CONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES PRIOR TO THE START OF CONSTRUCTION. 18. GENERAL CONTRACTOR SHALL COORDINATE AND MAINTAIN ACCESS FOR ALL TRADES AND CONTRACTORS TO THE SITE AND/OR BUILDING. 19. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SECURITY OF THE SITE FOR THE DURATION OF CONSTRUCTION UNTIL JOB COMPLETION. 20. THE GENERAL CONTRACTOR SHALL MAINTAIN IN GOOD CONDITION ONE COMPLETE SET OF PLANS WITH ALL REVISIONS, ADDENDA, AND CHANGE ORDERS ON THE PREMISES AT ALL TIMES. 21. THE GENERAL CONTRACTOR SHALL PROVIDE PORTABLE FIRE EXTINGUISHERS WITH A RATING OF NOT LESS THAN 2-A OT 2-A:10-B:C AND SHALL BE WITHIN 25 FEET OF TRAVEL DISTANCE TO ALL PORTIONS OF WHERE THE WORK IS BEING COMPLETED DURING CONSTRUCTION. 22. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES SHALL BE PROTECTED AT ALL TIMES, AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED AS DIRECTED BY THE ENGINEER AND RF. EXTREME CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING OR DRILLING PIERS AROUND OR NEAR UTILITIES. CONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW. THIS SHALL INCLUDE BUT NOT BE LIMITED TO A) FALL PROTECTION, B) CONFINED SPACE, C) ELECTRICAL SAFETY, AND D) TRENCHING & EXCAVATION. 23. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED, CAPPED, PLUGGED OR OTHERWISE DISCONNECTED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, AS DIRECTED BY THE RESPONSIBLE ENGINEER, AND SUBJECT TO THE APPROVAL OF THE OWNER AND/OR LOCAL UTILITIES. 24. THE AREAS OF THE OWNER'S PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THE TOWER, EQUIPMENT OR DRIVEWAY, SHALL BE GRADED TO A UNIFORM SLOPE, AND STABILIZED TO PREVENT EROSION. 25. CONTRACTOR SHALL MINIMIZE DISTURBANCE TO THE EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL MEASURES, IF REQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE FEDERAL AND LOCAL JURISDICTION FOR EROSION AND SEDIMENT CONTROL. 26. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUNDING. FROZEN MATERIALS, SNOW OR ICE SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT. 27. THE SUBGRADE SHALL BE BROUGHT TO A SMOOTH UNIFORM GRADE AND COMPACTED TO 95 PERCENT STANDARD PROCTOR DENSITY UNDER PAVEMENT AND STRUCTURES AND 80 PERCENT STANDARD PROCTOR DENSITY IN OPEN SPACE. ALL TRENCHES IN PUBLIC RIGHT OF WAY SHALL BE BACKFILLED WITH FLOWABLE FILL OR OTHER MATERIAL PRE-APPROVED BY THE LOCAL JURISDICTION. 28. ALL NECESSARY RUBBISH, STUMPS, DEBRIS, STICKS, STONES, AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF IN A LAWFUL MANNER. 29. ALL BROCHURES, OPERATING AND MAINTENANCE MANUALS, CATALOGS, SHOP DRAWINGS, AND OTHER DOCUMENTS SHALL BE TURNED OVER TO THE GENERAL CONTRACTOR AT COMPLETION OF CONSTRUCTION AND PRIOR TO PAYMENT. 30. CONTRACTOR SHALL SUBMIT A COMPLETE SET OF AS-BUILT REDLINES TO THE GENERAL CONTRACTOR UPON COMPLETION OF PROJECT AND PRIOR TO FINAL PAYMENT. 31. CONTRACTOR SHALL LEAVE PREMISES IN A CLEAN CONDITION. 32. THE PROPOSED FACILITY WILL BE UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SEWER SERVICE, AND IS NOT FOR HUMAN HABITAT (NO HANDICAP ACCESS REQUIRED). 33. OCCUPANCY IS LIMITED TO PERIODIC MAINTENANCE AND INSPECTION, APPROXIMATELY 2 TIMES PER MONTH, BY AT&T TECHNICIANS. 34. NO OUTDOOR STORAGE OR SOLID WASTE CONTAINERS ARE PROPOSED. 35. ALL MATERIAL SHALL BE FURNISHED AND WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST REVISION AT&T MOBILITY GROUNDING STANDARD "TECHNICAL SPECIFICATION FOR CONSTRUCTION OF GSM/GPRS WIRELESS SITES" AND "TECHNICAL SPECIFICATION FOR FACILITY GROUNDING". IN CASE OF A CONFLICT BETWEEN THE CONSTRUCTION SPECIFICATION AND THE DRAWINGS, THE DRAWINGS SHALL GOVERN. 36. CONTRACTORS SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS REQUIRED FOR CONSTRUCTION. IF CONTRACTOR CANNOT OBTAIN A PERMIT, THEY MUST NOTIFY THE GENERAL CONTRACTOR IMMEDIATELY. 37. CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE SITE ON A DAILY BASIS. 38. INFORMATION SHOWN ON THESE DRAWINGS WAS OBTAINED FROM SITE VISITS AND/OR DRAWINGS PROVIDED BY THE SITE OWNER. CONTRACTORS SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCIES PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION. 39. NO WHITE STROBE LIGHTS ARE PERMITTED. LIGHTING IF REQUIRED, WILL MEET FAA STANDARDS AND REQUIREMENTS. 40. ALL COAXIAL CABLE INSTALLATIONS TO FOLLOW MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. ANTENNA MOUNTING 41. DESIGN AND CONSTRUCTION OF ANTENNA SUPPORTS SHALL CONFORM TO CURRENT ANSI/TIA-222 OR APPLICABLE LOCAL CODES. 42. ALL STEEL MATERIALS SHALL BE GALVANIZED AFTER FABRICATION IN ACCORDANCE WITH ASTM A123 "ZINC (HOT-DIP GALVANIZED) COATINGS ON IRON AND STEEL PRODUCTS", UNLESS NOTED OTHERWISE. 43. ALL BOLTS, ANCHORS AND MISCELLANEOUS HARDWARE SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A153 "ZINC-COATING (HOT-DIP) ON IRON AND STEEL HARDWARE", UNLESS NOTED OTHERWISE. 44. DAMAGED GALVANIZED SURFACES SHALL BE REPAIRED BY COLD GALVANIZING IN ACCORDANCE WITH ASTM A780. 45. ALL ANTENNA MOUNTS SHALL BE INSTALLED WITH LOCK NUTS, DOUBLE NUTS AND SHALL BE TORQUED TO MANUFACTURER'S RECOMMENDATIONS. 56. ALL GROUNDING HARDWARE SHALL BE TIGHTENED UNTIL THE LOCK WASHER COLLAPSES AND THE GROUNDING HARDWARE IS NO LONGER LOOSE. 57. ALL DIN TYPE CONNECTIONS SHALL BE TIGHTENED TO 18-22 LB-FT (24.4 - 29.8 NM). 58. ALL N TYPE CONNECTIONS SHALL BE TIGHTENED TO 15-20 LB-IN (1.7 - 2.3 NM). FIBER & POWER CABLE MOUNTING 46. CONTRACTOR SHALL INSTALL ANTENNA PER MANUFACTURER'S RECOMMENDATION FOR INSTALLATION AND GROUNDING. 47. ALL UNUSED PORTS ON ANY ANTENNA SHALL BE COVERED WITH CONCEALOR &$3:,7+3523(5:($7+(53522),1*25%(7(50,1$7(':,7+$ȍ/2$' 48. PRIOR TO SETTING ANTENNA AZIMUTHS AND DOWNTILTS, ANTENNA CONTRACTOR SHALL CHECK THE ANTENNA MOUNT FOR TIGHTNESS AND ENSURE THAT THEY ARE PLUMB. ANTENNA AZIMUTHS SHALL BE SET FROM TRUE NORTH $1'%(25,(17(':,7+,1ƒ$6'(),1('%<7+(5)'6$17(11$'2:17,/76 6+$//%(:,7+,1ƒ$6'(),1('%<7+(5)'65()(5721' 49. JUMPERS WHERE REQUIRED MUST TERMINATE TO OPPOSITE POLARIZATION'S IN EACH SECTOR. 50. CONTRACTOR SHALL RECORD THE SERIAL #, SECTOR, AND POSITION OF EACH AT&T COMPONENT 51. TMA'S SHALL BE MOUNTED ON PIPE DIRECTLY BEHIND ANTENNAS AS CLOSE TO ANTENNA AS FEASIBLE IN A VERTICAL POSITION (IF REQUIRED). TORQUE REQUIREMENTS 52. ALL RF CONNECTIONS SHALL BE TIGHTENED BY A TORQUE WRENCH. 53. ALL RF CONNECTIONS, GROUNDING HARDWARE AND ANTENNA HARDWARE SHALL HAVE A TORQUE MARK INSTALLED IN A CONTINUOUS STRAIGHT LINE FROM BOTH SIDES OF THE CONNECTION. A. RF CONNECTION BOTH SIDES OF THE CONNECTOR. B. GROUNDING AND ANTENNA HARDWARE ON THE NUT SIDE STARTING FROM THE THREADS TO THE SOLID SURFACE. EXAMPLE OF SOLID SURFACE: GROUND BAR, ANTENNA BRACKET METAL. 54. ALL 8M ANTENNA HARDWARE SHALL BE TIGHTENED TO 9 LB-FT (12 NM). 55. ALL 12M ANTENNA HARDWARE SHALL BE TIGHTENED TO 43 LB-FT (58 NM). 61.WHEN INSTALLING OPTIC FIBER TRUNK CABLES OR TYPE TC-ER CABLES INTO CONDUITS, NFPA 70 (NEC) ARTICLE 300 RULES SHALL APPLY. 60.THE TYPE TC-ER CABLES SHALL BE INSTALLED INTO CONDUITS, CHANNEL CABLE TRAYS, OR CABLE TRAY AND SHALL BE SECURED AT INTERVALS NOT EXCEEDING (6) SIX FEET. AN EXCEPTION; WHERE TYPE TC-ER CABLES ARE NOT SUBJECT TO PHYSICAL DAMAGE, CABLES SHALL BE PERMITTED TO MAKE A TRANSITION BETWEEN CONDUITS, CHANNEL CABLE TRAYS, OR CABLE TRAY WHICH ARE SERVING UTILIZATION EQUIPMENT OR DEVICES, A DISTANCE (6) SIX FEET SHALL NOT BE EXCEEDED WITHOUT CONTINUOUS SUPPORTING. NFPA 70 (NEC) ARTICLES 336 AND 392 RULES SHALL APPLY. 59.THE FIBER OPTIC TRUNK CABLES SHALL BE INSTALLED INTO CONDUITS, CHANNEL CABLE TRAYS, OR CABLE TRAY. WHEN INSTALLING FIBER OPTIC TRUNK CABLES INTO A CABLE TRAY SYSTEM, THEY SHALL BE INSTALLED INTO AN INTER DUCT AND A PARTITION BARRIER SHALL BE INSTALLED BETWEEN THE 600 VOLT CABLES AND THE INTER DUCT IN ORDER TO SEGREGATE CABLE TYPES. OPTIC FIBER TRUNK CABLES SHALL HAVE APPROVED CABLE RESTRAINTS EVERY (6) SIX FEET AND SECURELY FASTENED TO THE CABLE TRAY SYSTEM. NFPA 70 (NEC) ARTICLE 770 RULES SHALL APPLY. 6/14/21 FINAL CD'S NP 839612 CM IDL01003 IDL01003 1250 WEST USTICK ROAD MERIDIAN, ID 83646 161 Inverness Drive West 2nd floor Englewood, Colorado 80112 PREPARED FOR: REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: BU NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Tower Owner: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: A&E: at&t 2055 SOUTH STEARMAN DRIVE CHANDLER, AZ 85286 B RAD CENTER CHANGE04/23/21 A 4/07/21 PRELIMINARY CD'S C RAD CENTER CHANGE06/01/21 0 SUBMITTAL CD'S06/03/21 0A 6/14/21 SUBMITTAL CD'S TIM ALEX A N D E RSIGNED, EXPIRES, 28 FEB 2023 GENERAL NOTES GN-2 DRAWING ABBREVIATIONS AFF AGL APPROX APPROXIMATELY AZ BLDG CM CAB CL CLG CLR CO CONC COND CONST CONT D/C DEMO AZIMUTH BUILDING CONSTRUCTION MANAGER CABINET CENTERLINE CEILING CLEAR COPPER CONCRETE CONDUIT CONSTRUCTION CONTINUOUS DRAFTER/CHECKER DEMOLISH ',$25‘',$0(7(5 DIM DN DTL DWG EA ELECT ELEV EQ EQUIP EXT FIN FLR FRP FT GA GALV GC GLB GWB GR GRND HVAC HORIZ HT IBC ID IN INSUL INT JBOX DETAIL DRAWING EACH ELECTRICAL ELEVATION EQUAL EQUIPMENT EXTERIOR FINISH FLOOR FIBERGLASS REINFORCED POLYMER FOOT, FEET GAUGE GALVANIZED GENERAL CONTRACTOR GLULAM BEAM GYPSUM WALL BOARD GRADE GROUND DIMENSION DOWN AWG AC ABOVE FINISH FLOOR ABOVE GRADE LEVEL AMERICAN WIRE GAUGE AIR CONDITIONING LF MAX MECH MFR MGR MIN MISC MTL MW NEC NIC NTS N/A OC OD OP OT OPP PL PM PROJ PROP PT RF RO ROW RRU REQ SBTC SF SHT SPEC SQ SS STL LINEAR FEET MAXIMUM MECHANICAL MANUFACTURER MANAGER MINIMUM MISCELLANEOUS METAL MICROWAVE NATIONAL ELECTRICAL CODE NOT IN CONTRACT NOT TO SCALE NOT APPLICABLE ON CENTER OUTSIDE DIAMETER OVERHEAD POWER OVERHEAD FIBER OPPOSITE PROPERTY LINE PLYWD PLYWOOD PROJECT MANAGER PROJECT PROPERTY PRESSURE TREATED RADIO-FREQUENCY ROUGH OPENING RIGHT OF WAY REMOTE RADIO UNIT REQUIRED SOLID BARE TINNED COPPER SQUARE FEET SHEET SPECIFICATION SQUARE STAINLESS STEEL STEEL STRUCT STRUCTURE, STRUCTURAL TOC TOM THRU TYP HEATING/VENTING/AIR CONDITIONING UBC HORIZONTAL HEIGHT UG UNO INTERNATIONAL BUILDING CODE INSIDE DIAMETER INCH INSULATION INTERIOR JUNCTION BOX LB(S) OR # POUND(S) UP UF VIF VERT WP W/ W/O TOP OF CONCRETE TOP OF MASONRY THROUGH TYPICAL UNIFORM BUILDING CODE UNDERGROUND UNLESS NOTED OTHERWISE UNDERGROUND POWER UNDERGROUND FIBER VERIFY IN FIELD VERTICAL WATERPROOF WITH WITHOUT CHAIN LINK FENCE WOOD/WROUGHT IRON FENCE WALL STRUCTURE LEASE AREA PROPERTY LINE (PL) SETBACKS ICE BRIDGE CABLE TRAY WATER LINE UNDERGROUND POWER UNDERGROUND TELCO OVERHEAD POWER OVERHEAD TELCO UNDERGROUND TELCO/POWER ABOVE GROUND POWER ABOVE GROUND TELCO ABOVE GROUND TELCO/POWER UG-P UG-T OH-P OH-T UG-P UG-T OH-P OH-T CHEMICAL ELECTROLYTIC GROUNDING SYSTEM TEST CHEMICAL ELECTROLYTIC GROUNDING SYSTEM EXOTHERMIC WITH INSPECTION SLEEVE GROUNDING BAR GROUND ROD TEST GROUND ROD WITH INSPECTION SLEEVE SINGLE POLE SWITCH DUPLEX RECEPTACLE DUPLEX GFCI RECEPTACLE FLUORESCENT LIGHTING FIXTURE SMOKE DETECTION (DC) EMERGENCY LIGHTING (DC) SECURITY LIGHT W/PHOTOCELL EXOTHERMIC CONNECTION MECHANICAL CONNECTION GENERAL CONSTRUCTION NOTES CONTINUED: COAXIAL CABLE NOTES GENERAL CABLE AND EQUIPMENT NOTES 74. IF REQUIRED TO PAINT ANTENNAS AND/OR COAX: $7(03(5$785(6+$//%($%29(ƒ) B. PAINT COLOR MUST BE APPROVED BY BUILDING OWNER/LANDLORD. C. FOR REGULATED TOWERS, FAA/FCC APPROVED PAINT IS REQUIRED. D. DO NOT PAINT OVER COLOR CODING OR ON EQUIPMENT MODEL NUMBERS. 76.ALL PROPOSED GROUND BAR DOWNLEADS ARE TO BE TERMINATED TO THE EXISTING ADJACENT GROUND BAR DOWNLEADS A MINIMUM DISTANCE OF 4'-0" BELOW GROUND BAR. TERMINATIONS MAY BE EXOTHERMIC OR COMPRESSION. 77.THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE ANTENNA AND THE COAX CONFIGURATION IS THE CORRECT MAKE AND MODELS, PRIOR TO INSTALLATION. 78.ALL CONNECTIONS FOR HANGERS, SUPPORTS, BRACING, ETC. SHALL BE INSTALLED PER TOWER MANUFACTURER'S SPECIFICATION & RECOMMENDATIONS. 79.ANTENNA CONTRACTOR SHALL FURNISH AND INSTALL A 12'-0" T-BOOM SECTOR ANTENNA MOUNT, IF APPLICABLE, INCLUDING ALL HARDWARE. 73.ALL OUTDOOR RF CONNECTORS/CONNECTIONS SHALL BE WEATHERPROOFED, EXCEPT THE RET CONNECTORS, USING BUTYL TAPE AFTER INSTALLATION AND FINAL CONNECTIONS ARE MADE. BUTYL TAPE SHALL HAVE A MINIMUM OF ONE-HALF TAPE WIDTH OVERLAP ON EACH TURN AND EACH LAYER SHALL BE WRAPPED THREE TIMES. WEATHERPROOFING SHALL BE SMOOTH WITHOUT BUCKLING. BUTYL BLEEDING IS NOT ALLOWED. SELF BONDING TAPE AND PLASTIC ENCLOSURES ALSO PERMITTED PER ATT-002-290-041 SECTION 7. 72.CONTRACTOR SHALL REFERENCE THE TOWER STRUCTURAL ANALYSIS/DESIGN DRAWINGS FOR DIRECTIONS ON CABLE DISTRIBUTION/ROUTING. 71.ALL CONNECTIONS FOR HANGERS, SUPPORTS, BRACING, ETC. SHALL BE INSTALLED PER TOWER MANUFACTURER'S RECOMMENDATIONS. 70.CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY ANTENNA, TMAS, DIPLEXERS, AND COAX CONFIGURATION, MAKE AND MODELS PRIOR TO INSTALLATION. 62.TYPES AND SIZES OF THE ANTENNA CABLE ARE BASED ON ESTIMATED LENGTHS. PRIOR TO ORDERING CABLE, CONTRACTOR SHALL VERIFY ACTUAL LENGTH BASED ON CONSTRUCTION LAYOUT AND NOTIFY THE PROJECT MANAGER IF ACTUAL LENGTHS EXCEED ESTIMATED LENGTHS. 63.CONTRACTOR SHALL VERIFY THE DOWN-TILT OF EACH ANTENNA WITH A DIGITAL LEVEL. 64.CONTRACTOR SHALL CONFIRM COAX COLOR CODING PRIOR TO CONSTRUCTION. REFER TO "ANTENNA SYSTEM LABELING STANDARD" ND-00027 LATEST VERSION. 65.CONTRACTOR SHALL FOLLOW ALL MANUFACTURER'S RECOMMENDATIONS REGARDING BOTH THE INSTALLATION AND GROUNDING OF ALL COAXIAL CABLES, CONNECTORS, ANTENNAS, AND ALL OTHER EQUIPMENT. 66.CONTRACTOR SHALL WEATHERPROOF ALL ANTENNA CONNECTORS WITH SELF AMALGAMATING TAPE WEATHERPROOFING SHALL BE COMPLETED IN STRICT ACCORDANCE WITH AT&T STANDARDS.. 6/14/21 FINAL CD'S NP 839612 CM IDL01003 IDL01003 1250 WEST USTICK ROAD MERIDIAN, ID 83646 161 Inverness Drive West 2nd floor Englewood, Colorado 80112 PREPARED FOR: REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: BU NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Tower Owner: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: A&E: at&t 2055 SOUTH STEARMAN DRIVE CHANDLER, AZ 85286 B RAD CENTER CHANGE04/23/21 A 4/07/21 PRELIMINARY CD'S C RAD CENTER CHANGE06/01/21 0 SUBMITTAL CD'S06/03/21 0A 6/14/21 SUBMITTAL CD'S TIM ALEX A N D E RSIGNED, EXPIRES, 28 FEB 2023 GENERAL NOTES GN-3 GENERAL SITE WORK & DRAINAGE NOTES: PART 1 - GENERAL CLEARING, GRUBBING, STRIPPING, EROSION CONTROL, SURVEY, LAYOUT, SUBGRADE PREPARATION AND FINISH GRADING AS REQUIRED TO COMPLETE THE PROPOSED WORK SHOWN IN THESE PLANS. 1.1 REFERENCES: A. DOT (STATE DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS FOR HIGHWAY CONSTRUCTION-CURRENT EDITION). B. ASTM (AMERICAN SOCIETY FOR TESTING AND MATERIALS). C. OSHA (OCCUPATION SAFETY AND HEALTH ADMINISTRATION). 1.2 INSPECTION AND TESTING: A. FIELD TESTING OF EARTHWORK COMPACTION AND CONCRETE CYLINDERS SHALL BE PERFORMED BY SUBCONTRACTORS INDEPENDENT TESTING LAB. THIS WORK TO BE COORDINATED BY THE SUBCONTRACTOR. B. ALL WORK SHALL BE INSPECTED AND RELEASED BY THE GENERAL CONTRACTOR WHO SHALL CARRY OUT THE GENERAL INSPECTION OF THE WORK WITH SPECIFIC CONCERN TO PROPER PERFORMANCE OF THE WORK AS SPECIFIED AND/OR CALLED FOR ON THE DRAWINGS. IT IS THE SUBCONTRACTOR'S RESPONSIBILITY TO REQUEST TIMELY INSPECTIONS PRIOR TO PROCEEDING WITH FURTHER WORK THAT WOULD MAKE PARTS OF WORK INACCESSIBLE OR DIFFICULT TO INSPECT. 1.3 SITE MAINTENANCE AND PROTECTION: A. PROVIDE ALL NECESSARY JOB SITE MAINTENANCE FROM COMMENCEMENT OF WORK UNTIL COMPLETION OF THE SUBCONTRACT. B. AVOID DAMAGE TO THE SITE AND TO EXISTING FACILITIES, STRUCTURES, TREES, AND SHRUBS DESIGNATED TO REMAIN. TAKE PROTECTIVE MEASURES TO PREVENT EXISTING FACILITIES THAT ARE NOT DESIGNATED FOR REMOVAL FROM BEING DAMAGED BY THE WORK. C. KEEP SITE FREE OF ALL PONDING WATER. D. PROVIDE EROSION CONTROL MEASURES IN ACCORDANCE WITH STATE DOT AND EPA REQUIREMENTS. E. PROVIDE AND MAINTAIN ALL TEMPORARY FENCING, BARRICADES, WARNING SIGNALS AND SIMILAR DEVICES NECESSARY TO PROTECT AGAINST THEFT FROM PROPERTY DURING THE ENTIRE PERIOD OF CONSTRUCTION. REMOVE ALL SUCH DEVICES UPON COMPLETION OF THE WORK. F. EXISTING UTILITIES: DO NOT INTERRUPT EXISTING UTILITIES SERVING FACILITIES OCCUPIED BY THE OWNER OR OTHERS, EXCEPT WHEN PERMITTED IN WRITING BY THE ENGINEER AND THEN ONLY AFTER ACCEPTABLE TEMPORARY UTILITY SERVICES HAVE BEEN PROVIDED. 1. PROVIDE A MINIMUM 48-HOUR NOTICE TO THE ENGINEER AND RECEIVE WRITTEN NOTICE TO PROCEED BEFORE INTERRUPTING ANY UTILITY SERVICE. PART 2 - PRODUCTS 2.1 SUITABLE BACKFILL: ASTM D2321 (CLASS I, II, III OR IVA) FREE FROM FROZEN LUMPS, REFUSE, STONES OR ROCKS LARGER THAN 3 INCHES IN ANY DIMENSION OR OTHER MATERIAL THAT MAY MAKE THE INORGANIC MATERIAL UNSUITABLE FOR BACKFILL. 2.2 NON-POROUS GRANULAR EMBANKMENT AND BACKFILL: ASTM D2321 (CLASS III, IVA OR IVB) COARSE AGGREGATE. FREE FROM FROZEN LUMPS, REFUSE, STONES OR ROCKS LARGER THAN 3 INCHES IN ANY DIMENSION OR OTHER MATERIAL THAT MAY MAKE THE INORGANIC MATERIAL UNSUITABLE FOR BACKFILL. 2.3 POROUS GRANULAR EMBANKMENT AND BACKFILL: ASTM D2321 (CLASS IA, IB OR II) COARSE AGGREGATE FREE FROM FROZEN LUMPS, REFUSE, STONES OR ROCKS LARGER THAN 3 INCHES IN ANY DIMENSION OR OTHER MATERIAL THAT MAY MAKE THE INORGANIC MATERIAL UNSUITABLE FOR BACKFILL. 2.4 SELECT STRUCTURAL FILL: GRANULAR FILL MATERIAL MEETING THE REQUIREMENTS OF ASTM E850-95. FOR USE AROUND AND UNDER STRUCTURES WHERE STRUCTURAL FILL MATERIAL ARE REQUIRED. 2.5 GRANULAR BEDDING AND TRENCH BACKFILL: WELL-GRADED SAND MEETING THE GRADATION REQUIREMENTS OF ASTM D2487 (SE OR SW-SM). 2.6 COARSE AGGREGATE FOR ACCESS ROAD SUBBASE COURSE SHALL CONFORM TO ASTM D2940. 2.7 UNSUITABLE MATERIAL: HIGH AND MODERATELY PLASTIC SILTS AND CLAYS (LL>45). MATERIAL CONTAINING REFUSE, FROZEN LUMPS, DEMOLISHED BITUMINOUS MATERIAL, VEGETATIVE MATTER, WOOD, STONES IN EXCESS OF 3 INCHES IN ANY DIMENSION, AND DEBRIS AS DETERMINED BY THE CONSTRUCTION MANAGER. TYPICAL THESE WILL BE SOILS CLASSIFIED BY ASTM AS PT, MH, CH, OH, ML, AND OL. 2.8 GEOTEXTILE FABRIC: MIRAFI 500X OR ENGINEERED APPROVED EQUAL. A. UTILITY TRENCHES SHALL BE EXCAVATED TO THE LINES AND GRADES SHOWN ON THE DRAWINGS OR AS DIRECTED BY THE GENERAL CONTRACTOR. PROVIDE SHORING, SHEETING AND BRACING AS REQUIRED TO PREVENT CAVING OR SLOUGHING OF THE TRENCH WALLS. B. EXTEND THE TRENCH WIDTH A MINIMUM OF 6 INCHES BEYOND THE OUTSIDE EDGE OF THE OUTERMOST CONDUIT. C. WHEN SOFT YIELDING, OR OTHERWISE UNSTABLE SOIL CONDITIONS ARE ENCOUNTERED, BACKFILL AT THE REQUIRED TRENCH TO A DEPTH OF NO LESS THAN 12 INCHES BELOW THE REQUIRED ELEVATION AND BACKFILL WITH GRANULAR BEDDING MATERIAL. 2.9 PLASTIC MARKING TAPE: SHALL BE ACID AND ALKALI RESISTANT POLYETHYLENE FILM SPECIFICALLY MANUFACTURED FOR MARKING AND LOCATING UNDERGROUND UTILITIES, 6 INCHES WIDE WITH A MINIMUM THICKNESS OF 0.004 INCH. TAPE SHALL HAVE MINIMUM STRENGTH OF 1500 PSI IN BOTH DIRECTIONS AND MANUFACTURED WITH INTEGRAL CONDUCTORS, FOIL BACKING OR OTHER MEANS TO ENABLE DETECTION BY A METAL DETECTOR WHEN BURIED UP TO 3 FEET DEEP. THE METALLIC CORE OF THE TAPE SHALL BE ENCASED IN A PROTECTIVE JACKET OR PROVIDED WITH OTHER MEANS TO PROTECT IT FROM CORROSION. TAPE COLOR SHALL BE RED FOR ELECTRIC UTILITIES AND ORANGE FOR TELECOMMUNICATION UTILITIES. PART 3 - EXECUTION 3.1 GENERAL: A. BEFORE STARTING GENERAL SITE PREPARATION ACTIVITIES, INSTALL EROSION AND SEDIMENT CONTROL MEASURES. THE WORK AREA SHALL BE CONSTRUCTED AND MAINTAINED IN SUCH CONDITION THAT IN THE EVENT OF RAIN THE SITE WILL BE DRAINED AT ANY TIME. B. BEFORE ALL SURVEY, LAYOUT, STAKING, AND MARKING, ESTABLISH AND MAINTAIN ALL LINES, GRADES, ELEVATIONS AND BENCHMARKS NEEDED FOR EXECUTION OF THE WORK. C. CLEAR AND GRUB THE AREA WITHIN THE LIMITS OF THE SITE. REMOVE TREES, BRUSH, STUMPS, RUBBISH AND OTHER DEBRIS AND VEGETATION RESTING ON OR PROTRUDING THROUGH THE SURFACE OF THE SITE AREA TO BE CLEARED. 1. REMOVE THE FOLLOWING MATERIALS TO A DEPTH OF NO LESS THAN 12 INCHES BELOW THE ORIGINAL GROUND SURFACE: ROOTS, STUMPS, AND OTHER DEBRIS, BRUSH, AND REFUSE EMBEDDED IN OR PROTRUDING THROUGH THE GROUND SURFACE, RAKE, DISK OR PLOW THE AREA TO A DEPTH OF NO LESS THAN 6 INCHES, AND REMOVE TO A DEPTH OF 12 INCHES ALL ROOTS AND OTHER DEBRIS THEREBY EXPOSED. 2. REMOVE TOPSOIL MATERIAL COMPLETELY FROM THE SURFACE UNTIL THE SOIL NO LONGER MEETS THE DEFINITION OF TOPSOIL. AVOID MIXING TOPSOIL WITH SUBSOIL OR OTHER UNDESIRABLE MATERIALS. 3. EXCEPT WHERE EXCAVATION TO GREATER DEPTH IS INDICATED, FILL DEPRESSIONS RESULTING FROM CLEARING, GRUBBING AND DEMOLITION WORK COMPLETELY WITH SUITABLE FILL. A. REMOVE FROM THE SITE AND DISPOSE IN AN AUTHORIZED LANDFILL ALL DEBRIS RESULTING FROM CLEARING AND GRUBBING OPERATIONS. BURNING WILL NOT BE PERMITTED. B. PRIOR TO EXCAVATING, THOROUGHLY EXAMINE THE AREA TO BE EXCAVATED AND/OR TRENCHED TO VERIFY THE LOCATIONS OF FEATURES INDICATED ON THE DRAWINGS AND TO ASCERTAIN THE EXISTENCE AND LOCATION OF ANY STRUCTURE, UNDERGROUND STRUCTURE, OR OTHER ITEM NOT SHOWN THAT MIGHT INTERFERE WITH THE PROPOSED CONSTRUCTION. NOTIFY THE CONSTRUCTION MANAGER OF ANY OBSTRUCTIONS THAT WILL PREVENT ACCOMPLISHMENT OF THE WORK AS INDICATED ON THE DRAWINGS. C. SEPARATE AND STOCK PILE ALL EXCAVATED MATERIALS SUITABLE FOR BACKFILL. ALL EXCESS EXCAVATED AND UNSUITABLE MATERIALS SHALL BE DISPOSED OF OFF-SITE IN A LEGAL MANNER. 3.2 BACKFILL: A. AS SOON AS PRACTICAL, AFTER COMPLETING CONSTRUCTION OF THE RELATED STRUCTURE, INCLUDING EXPIRATION OF THE SPECIFIED MINIMUM CURING PERIOD FOR CAST-IN-PLACE CONCRETE, BACKFILL THE EXCAVATION WITH APPROVED MATERIAL TO RESTORE THE REQUIRED FINISHED GRADE. 1. PRIOR TO PLACING BACKFILL AROUND STRUCTURES, ALL FORMS SHALL BE REMOVED AND THE EXCAVATION CLEANED OF ALL TRASH, DEBRIS, AND UNSUITABLE MATERIALS. 2. BACKFILL BY PLACING AND COMPACTING SUITABLE BACKFILL MATERIAL OR SELECT GRANULAR BACKFILL MATERIAL WHEN REQUIRED IN UNIFORM HORIZONTAL LAYERS OF NO GREATER THAN 8-INCHES LOOSE THICKNESS AND COMPACTED. WHERE HAND OPERATED COMPACTORS ARE USED, THE FILL MATERIAL SHALL BE PLACED IN LIFTS NOT TO EXCEED 4 INCHES IN LOOSE DEPTH AND COMPACTED. 3. WHENEVER THE DENSITY TESTING INDICATES THAT THE CONTRACTOR HAS NOT OBTAINED THE SPECIFIED DENSITY, THE SUCCEEDING LAYER SHALL NOT BE PLACED UNTIL THE SPECIFICATION REQUIREMENTS ARE MET UNLESS OTHERWISE AUTHORIZED BY THE GEOTECHNICAL ENGINEER. THE CONTRACTOR SHALL TAKE WHATEVER APPROPRIATE ACTION IS NECESSARY, SUCH AS DISKING AND DRYING, ADDING WATER, OR INCREASING THE COMPACTIVE EFFORT TO MEET THE MINIMUM COMPACTION REQUIREMENTS. B. THOROUGHLY COMPACT EACH LAYER OF BACKFILL TO A MINIMUM OF 95 PERCENT OF THE MAXIMUM DRY DENSITY AS PROVIDED BY THE STANDARD PROCTOR TEST, ASTM D 698. 3.3 TRENCH EXCAVATION: 3.4 TRENCH BACKFILL: A. PROVIDE GRANULAR BEDDING MATERIAL IN ACCORDANCE WITH THE DRAWINGS AND THE UTILITY REQUIREMENTS. B. NOTIFY THE GENERAL CONTRACTOR 24 HOURS IN ADVANCE OF BACKFILLING. C. CONDUCT UTILITY CHECK TESTS BEFORE BACKFILLING. BACKFILL AND COMPACT TRENCH BEFORE ACCEPTANCE TESTING. D. PLACE GRANULAR TRENCH BACKFILL UNIFORMLY ON BOTH SIDES OF THE CONDUITS IN 6-INCH UNCOMPACTED LIFTS UNTIL 12 INCHES OVER THE CONDUITS. SOLIDLY RAM AND TAMP BACKFILL INTO SPACE AROUND CONDUITS. E. PROTECT CONDUIT FROM LATERAL MOVEMENT, IMPACT DAMAGE, OR UNBALANCED LOADING. F. ABOVE THE CONDUIT EMBEDMENT ZONE, PLACE AND COMPACT SATISFACTORY BACKFILL MATERIAL IN 8-INCH MAXIMUM LOOSE THICKNESS LIFTS TO RESTORE THE REQUIRED FINISHED SURFACE GRADE. G. COMPACT FINAL TRENCH BACKFILL TO A DENSITY EQUAL TO OR GREATER THAN THAT OF THE EXISTING UNDISTURBED MATERIAL IMMEDIATELY ADJACENT TO THE TRENCH BUT NO LESS THAN A MINIMUM OF 95 PERCENT OF THE MAXIMUM DRY DENSITY AS PROVIDED BY THE STANDARD PROCTOR TEST, ASTM D 698. 3.5 AGGREGATE ACCESS ROAD: A. CLEAR, GRUB, STRIP AND EXCAVATE FOR THE ACCESS ROAD TO THE LINES AND GRADES INDICATED ON THE DRAWINGS. SCARIFY TO A DEPTH OF 6 INCHES AND PROOF-ROLL. ALL HOLES, RUTS, SOFT PLACES AND OTHER DEFECTS SHALL BE CORRECTED. B. THE ENTIRE SUBGRADE SHALL BE COMPACTED TO NOT LESS THAN 95 PERCENT OF THE MAXIMUM DRY DENSITY AS PROVIDED BY THE MODIFIED PROCTOR TEST, ASTM D 1557. C. AFTER PREPARATION OF THE SUBGRADE IS COMPLETE THE GEOTEXTILE FABRIC (MIRAFI 500Xi) SHALL BE INSTALLED TO THE LIMITS INDICATED ON THE DRAWINGS BY ROLLING THE FABRIC OUT LONGITUDINALLY ALONG THE ROADWAY. THE FABRIC SHALL NOT BE DRAGGED ACROSS THE SUBGRADE. PLACE THE ENTIRE ROLL IN A SINGLE OPERATION, ROLLING OUT AS SMOOTHLY AS POSSIBLE. 1. OVERLAPS PARALLEL TO THE ROADWAY WILL BE PERMITTED AT THE CENTERLINE AND AT LOCATIONS BEYOND THE ROADWAY SURFACE WIDTH (I.E. WITHIN THE SHOULDER WIDTH) ONLY. NO LONGITUDINAL OVERLAPS SHALL BE LOCATED BETWEEN THE CENTERLINE AND THE SHOULDER. PARALLEL OVERLAPS SHALL BE A MINIMUM OF 3 FEET WIDE. 2. TRANSVERSE (PERPENDICULAR TO THE ROADWAY) OVERLAPS AT THE END OF A ROLL SHALL OVERLAP IN THE DIRECTION OF THE AGGREGATE PLACEMENT (PREVIOUS ROLL ON TOP) AND SHALL HAVE A MINIMUM LENGTH OF 3 FEET. 3. ALL OVERLAPS SHALL BE PINNED WITH STAPLES OR NAILS A MINIMUM OF 10 INCHES LONG TO INSURE POSITIONING DURING PLACEMENT OF AGGREGATE. PIN LONGITUDINAL SEAMS AT 25 FOOT CENTERS AND TRANSVERSE SEAMS EVERY 5 FEET. D. THE AGGREGATE BASE AND SURFACE COURSES SHALL BE CONSTRUCTED IN LAYERS NOT MORE THAN 4 INCH (COMPACTED) THICKNESS. AGGREGATE TO BE PLACED ON GEOTEXTILE FABRIC SHALL BE END-DUMPED ON THE FABRIC FROM THE FREE END OF THE FABRIC OR OVER PREVIOUSLY PLACED AGGREGATE. THE FIRST LIFT SHALL BE BLADED DOWN TO A THICKNESS OF 8 INCHES PRIOR TO COMPACTION. AT NO TIME SHALL EQUIPMENT, EITHER TRANSPORTING THE AGGREGATE OR GRADING THE AGGREGATE, BE PERMITTED ON THE ROADWAY WITH LESS THAN 4 INCHES OF MATERIAL COVERING THE FABRIC. E. THE AGGREGATE SHALL BE IMMEDIATELY COMPACTED TO NOT LESS THAN 95 PERCENT OF THE MAXIMUM DRY DENSITY AS PROVIDED BY THE MODIFIED PROCTOR TEST, ASTM D 1557 WITH A TAMPING ROLLER, OR WITH A PNEUMATIC-TIRED ROLLER, OR WITH A VIBRATORY MACHINE OR ANY COMBINATION OF THE ABOVE. THE TOP LAYER SHALL BE GIVEN A FINAL ROLLING WITH A THREE-WHEEL OR TANDEM ROLLER. 3.6 FINISH GRADING: A. PERFORM ALL GRADING TO PROVIDE POSITIVE DRAINAGE AWAY FROM STRUCTURES AND SMOOTH, EVEN SURFACE DRAINAGE OF THE ENTIRE AREA WITHIN THE LIMITS OF CONSTRUCTION. GRADING SHALL BE COMPATIBLE WITH ALL SURROUNDING TOPOGRAPHY AND STRUCTURES. B. UTILIZE SATISFACTORY FILL MATERIAL RESULTING FROM THE EXCAVATION WORK IN THE CONSTRUCTION OF FILLS, EMBANKMENTS AND FOR REPLACEMENT OF REMOVED UNSUITABLE MATERIALS. C. ACHIEVE FINISHED GRADE BY PLACING A MINIMUM OF 4 INCHES OF 1/2" - 3/4" CRUSHED STONE ON TOP SOIL STABILIZER FABRIC. D. REPAIR ALL ACCESS ROADS AND SURROUNDING AREAS USED DURING THE COURSE OF THIS WORK TO THEIR ORIGINAL CONDITION. 6/14/21 FINAL CD'S NP 839612 CM IDL01003 IDL01003 1250 WEST USTICK ROAD MERIDIAN, ID 83646 161 Inverness Drive West 2nd floor Englewood, Colorado 80112 PREPARED FOR: REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: BU NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Tower Owner: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: A&E: at&t 2055 SOUTH STEARMAN DRIVE CHANDLER, AZ 85286 B RAD CENTER CHANGE04/23/21 A 4/07/21 PRELIMINARY CD'S C RAD CENTER CHANGE06/01/21 0 SUBMITTAL CD'S06/03/21 0A 6/14/21 SUBMITTAL CD'S TIM ALEX A N D E RSIGNED, EXPIRES, 28 FEB 2023 GENERAL NOTES GN-4 GENERAL CONCRETE WORK NOTES: PART 1 - GENERAL 1.1 SCOPE: A. 1.2REFERENCES: A. FORM WORK, REINFORCING STEEL, ACCESSORIES, CAST-IN PLACE CONCRETE, FINISHING, CURING AND TESTING FOR STRUCTURAL CONCRETE FOUNDATIONS. PART 3 - EXECUTION 3.1 GENERAL: A. B. C. ACI (AMERICAN CONCRETE INSTITUTE) 1. ACI 301 SPECIFICATION FOR STRUCTURAL CONCRETE FOR BUILDINGS. 2. ACI 304 RECOMMENDED PRACTICE FOR MEASURING, MIXING, TRANSPORTING AND PLACING CONCRETE. 3. ACI 305 RECOMMENDED PRACTICE FOR HOT WEATHER CONCRETING. 4. ACI 306 RECOMMENDED PRACTICE FOR COLD WEATHER CONCRETING. 5. ACI 308 STANDARD PRACTICE FOR CURING CONCRETING. 6. ACI 309 STANDARD PRACTICE FOR CONSOLIDATION OF CONCRETE. 7. ACI 318 BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE. 8. ACI 347 RECOMMENDED PRACTICE FOR CONCRETE FORMWORK. B. B. C. D. 3.2 INSERTS, EMBEDDED COMPONENTS AND OPENINGS: A. B. CONTRACTOR SHALL CHECK ALL CIVIL, ARCHITECTURAL, STRUCTURAL AND ELECTRICAL DRAWINGS FOR OPENINGS, SLEEVES, ANCHOR BOLTS, INSERTS AND OTHER ITEMS TO BE BUILT INTO THE CONCRETE WORK. 1. COORDINATE THE WORK OF OTHER SECTION IN FORMING AND SETTING OPENINGS. RECESSES, SLOTS, CHASES, ANCHORS, INSERTS AND OTHER ITEMS TO BE EMBEDDED. EMBEDDED ITEMS SHALL BE SET ACCURATELY IN LOCATION, ALIGNMENT, ELEVATION AND PLUMBNESS, LOCATE AND MEASURE FROM ESTABLISHED SURVEYED REFERENCE BENCHMARKS. EMBEDDED ITEMS SHALL BE ANCHORED INTO PLACE IN A MANNER TO PREVENT MOVEMENT DURING CONCRETE PLACEMENT AND CONSOLIDATION. COMPONENTS FORMING A PART OF A COMPLETE ASSEMBLY SHALL BE ALIGNED BEFORE ANCHORING INTO PLACE. PROVIDE TEMPORARY BRACING, ANCHORAGE, AND TEMPLATES AS REQUIRED TO MAINTAIN THE SETTING AND ALIGNMENT. ASTM (AMERICAN SOCIETY FOR TESTING AND MATERIALS). THE APPLICABLE STANDARDS OF THE AMERICAN SOCIETY FOR TESTING AND MATERIALS ARE LISTED IN THE ACI STANDARDS AND ARE A PART OF THIS SPECIFICATION. PART 2 - PRODUCTS 2.1REINFORCING MATERIALS: A. B. 3.3 REINFORCEMENT PLACEMENT: A. B. REINFORCING BARS: ASTM A615, GRADE 60, PROPOSED DEFORMED BILLET-STEEL BARS, PLAIN FINISH. C. FURNISH CHAIRS, BOLSTERS, BAR SUPPORTS, SPACERS AS REQUIRED FOR SUPPORT OF REINFORCING STEEL AND WIRE FABRIC. 2.2 CONCRETE MATERIALS: A. B. D. PORTLAND CEMENT SHALL BE TYPE II, CONFORMING TO ASTM C-150. E. AGGREGATE SHALL CONFORM TO ASTM C-33. 1. FINE AGGREGATE SHALL BE UNIFORMLY GRADED, CLEAN SHARP, WASHED NATURAL, OR CRUSHED SAND, FREE FROM ORGANIC IMPURITIES. 2. COARSE AGGREGATE SHALL BE NATURAL WASHED GRAVEL OR WASHED CRUSHED ROCK HAVING HARD, STRONG, DURABLE PIECES, FREE FROM ADHERENT COATINGS. 3. MAXIMUM SIZE OF COARSE AGGREGATE SHALL BE 3/4 INCH IN ACCORDANCE WITH THE REQUIREMENTS OF ASTM C-33 GRADATION SIZE NO. 67. C. D. WATER USED IN CONCRETE MIX SHALL BE POTABLE, CLEAN, AND FREE FROM OILS, ACIDS, SALTS, CHLORIDES, ALKALI, SUGAR, VEGETABLE, OR OTHER INJURIOUS SUBSTANCES. THE CONCRETE SHALL CONTAIN AN AIR-ENTRAINING ADMIXTURE COMPLYING WITH THE REQUIREMENTS OF ASTM C-260 AND ACI 212. 1R AND A WATER- REDUCING ADMIXTURE COMPLYING WITH THE REQUIREMENTS OF ASTM C-494 AND ACI 212. 1R. ADMIXTURES SHALL BE PURCHASED AND BATCHED IN LIQUID SOLUTION. THE USE OF CALCIUM CHLORIDE OR AN ADMIXTURE CONTAINING CALCIUM CHLORIDE IS PROHIBITED. ADMIXTURES SHALL BE OF THE SAME MANUFACTURER TO ASSURE COMPATIBILITY. ACCEPTABLE MANUFACTURERS ARE: 1. W.R. GRACE 2. SIKA CORP. 3. MASTER BUILDERS 4. EUCLID CHEMICAL CO. E. 2.3CONCRETE MIX: A. B. WELDING OF AND TO ANY REINFORCING MATERIALS INCLUDING TACK WELDING OF CROSSING BARS IS STRICTLY PROHIBITED. 3.4 CONCRETE PLACEMENT: A. 2. 3. 4. 5. 6. C. PLACE REINFORCEMENT ACCORDING TO CHECKED AND RELEASED DRAWINGS AND IN ACCORDANCE WITH ACI 301 AND ACI 318. ACCURATELY POSITION, SUPPORT AND SECURE REINFORCEMENT AGAINST DISPLACEMENT FROM FORM WORK CONSTRUCTION OR CONCRETE PLACEMENT AND CONSOLIDATION. SUPPORT REINFORCING ON METAL CHAIRS, RUNNERS, BOLSTERS, SPACERS AND HANGERS. SPLICES OF REINFORCING BARS SHALL BE CLASS B UNLESS SHOWN OTHERWISE ON THE DRAWINGS. SPLICES SHALL BE STAGGERED. FULL DEVELOPMENT LENGTH SHALL BE PROVIDED ACROSS JOINTS. LOCATE REINFORCING TO PROVIDE CONCRETE COVER AND SPACING SHOWN ON THE DRAWINGS. MINIMUM COVER SHALL BE AS REQUIRED BY ACI 318. PRIOR TO PLACING CONCRETE, THE FORMS AND REINFORCEMENT SHALL BE THOROUGHLY INSPECTED; ALL TEMPORARY BRACING, TIES AND CLEATS REMOVED; ALL OPENINGS FOR UTILITIES PROPERLY BOXED; ALL FORMS PROPERLY SECURED IN THERE CORRECT POSITION AND MADE TIGHT. ALL REINFORCEMENT AND EMBEDDED ITEMS SHALL BE SECURED IN THEIR PROPER LOCATIONS. ALL OLD AND DRY CONCRETE AND DIRT SHALL BE CLEANED OFF AND ALL STANDING WATER AND OTHER FOREIGN MATERIAL REMOVED. PLACING CONCRETE SHALL BE IN ACCORDANCE WITH ACI 301 AND ACI 304 AND SHALL BE CARRIED OUT AT SUCH A RATE THAT THE CONCRETE PREVIOUSLY PLACED IS STILL PLASTIC AND INTEGRATED WITH THE FRESHLY PLACED CONCRETE. CONCRETING ONCE STARTED, SHALL BE CARRIED ON AS A CONTINUOUS OPERATION UNTIL THE SECTION IS COMPLETED. NO COLD JOINTS SHALL BE ALLOWED. C.ALL CONCRETE SHALL BE THOROUGHLY CONSOLIDATED AND COMPACTED BY VIBRATION SPACING, RODDING, OR FORKING DURING THE OPERATION OF PLACING AND DEPOSITING IN ACCORDANCE WITH ACI 309. THE CONCRETE SHALL BE THOROUGHLY WORKED AROUND REINFORCEMENT, EMBEDDED ITEMS, AND INTO THE CORNER OF THE FORMS SO AS TO ELIMINATE ALL AIR AND STONE POCKETS. 3.5 FINISHING: A. CURING COMPOUND SHALL CONFORM TO ASTM C309, TYPE I, ID, CLASS A AND B AND ASTM C171 AS APPLICABLE. B. C. PROPORTION CONCRETE MIX IN ACCORDANCE WITH REQUIREMENTS OF ACI 301. THE STRENGTH OF CONCRETE SHALL BE AS INDICATED ON THE DRAWINGS. WHERE STRENGTH IS NOT CLEARLY INDICATED, CONCRETE OF MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 4000 P.S.I. SHALL BE USED. B.THE CONCRETE MIX SHALL BE DESIGNED FOR A MAXIMUM SLUMP OF THREE INCHES AT THE POINT OF DISCHARGE. MIXES OF THE STIFFEST CONSISTENCY THAT CAN BE EFFICIENTLY PLACED SHALL BE USED. C. D. ALL CONCRETE SHALL HAVE (3) TO FIVE (5) PERCENT ENTRAINED AIR. ALL STRUCTURAL CONCRETE SHALL CONTAIN A WATER-REDUCING AGENT. FINISHING OF THE FLOOR SLABS SHALL BE IN ACCORDANCE WITH ACI 302.1 SECTION 7.2 WITH A MINIMUM OF THREE TROWELINGS. THE SLAB FINISH TOLERANCE AS MEASURED IN ACCORDANCE WITH ASTM E 1155 SHALL HAVE AN OVERALL TEST NUMBER FOR FLATNESS, FF= 20 AND FOR LEVEL. FL=15. THE MINIMUM LOCAL NUMBER FOR FLATNESS, FF= 15 AND FOR LEVEL FL=10. SURFACE OF FLOOR SLAB SHALL RECEIVE TWO COATS OF CLEAR SEALER/HARDNER. ABOVE GRADE WALL SURFACES SHALL HAVE A SMOOTH FORM FINISH AS DEFINED IN CHAPTER 10 OF ACI 301. CONCRETE SHALL BE KEPT CONTINUOUSLY MOIST AT LEAST OVERNIGHT, IMMEDIATELY FOLLOWING THE INITIAL CURING. BEFORE THE CONCRETE HAS DRIED. ADDITIONAL CURING SHALL BE ACCOMPLISHED BY ONE OF THE FOLLOWING MATERIALS OR METHODS: PONDING OR CONTINUOUS SPRINKLING. ABSORPTIVE MAT OR FABRIC KEPT CONTINUOUSLY WET. NON-ABSORPTIVE FILM (POLYETHYLENE) OVER PREVIOUSLY SPRINKLED SURFACE. SAND OR OTHER COVERING KEPT CONTINUOUSLY WET. CONTINUOUS STEAM (NOT EXCEEDING 150 F) OR VAPOR MIST BATH. SPRAYED- ON CURING COMPOUND APPLIED IN TWO COATS, SPRAYED IN PERPENDICULAR DIRECTION THE FINAL CURING SHALL CONTINUE UNTIL THE CUMULATIVE NUMBER OF DAYS OR FRACTION THEREOF, NOT NECESSARILY CONSECUTIVE, DURING WHICH TEMPERATURE OF THE AIR IN CONTACT WITH CONCRETE IS ABOVE 50F HAS TOTALED SEVEN (7) DAYS. CONCRETE SHALL NOT BE PERMITTED TO FREEZE DURING THE CURING PERIOD. RAPID DRYING AT THE END OF THE CURING PERIOD SHALL BE PREVENTED. CONSTRUCT AND ERECT THE FORM WORK IN ACCORDANCE WITH ACI 301 AND ACI 347. COLD-WEATHER CONCRETING SHALL BE IN ACCORDANCE WITH ACI 306. HOT-WEATHER CONCRETING SHALL BE IN ACCORDANCE WITH ACI 305. 3.6 CURING: A.FRESHLY DEPOSITED CONCRETE SHALL BE PROTECTED FROM PREMATURE DRYING AND EXCESSIVELY HOT AND COLD TEMPERATURES AND SHALL BE MAINTAINED WITH MINIMUM MOISTURE LOSS AT A RELATIVELY CONSTANT TEMPERATURE FOR A PERIOD OF TIME NECESSARY FOR THE HYDRATION OF THE CEMENT AND PROPER HARDENING OF THE CONCRETE. 6/14/21 FINAL CD'S NP 839612 CM IDL01003 IDL01003 1250 WEST USTICK ROAD MERIDIAN, ID 83646 161 Inverness Drive West 2nd floor Englewood, Colorado 80112 PREPARED FOR: REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: BU NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Tower Owner: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: A&E: at&t 2055 SOUTH STEARMAN DRIVE CHANDLER, AZ 85286 B RAD CENTER CHANGE04/23/21 A 4/07/21 PRELIMINARY CD'S C RAD CENTER CHANGE06/01/21 0 SUBMITTAL CD'S06/03/21 0A 6/14/21 SUBMITTAL CD'S TIM ALEX A N D E RSIGNED, EXPIRES, 28 FEB 2023 GENERAL NOTES GN-5 PART 1 - GENERAL 1.1 SCOPE: PART 3 - EXECUTION 3.1 FABRICATION: A. SHOP FABRICATE AND ASSEMBLY MATERIALS AS SPECIFIED HEREIN. A. PROVIDE FABRICATION AND ERECTION OF STRUCTURAL STEEL AND OTHER ITEMS AS SHOWN ON THE DRAWINGS OR REQUIRED BY OTHER SECTIONS OF THESE SPECIFICATIONS. 1.2 REFERENCES: 2. ALL EXPOSED STRUCTURAL STEEL SHALL BE HOT DIP GALVANIZED PER ASTM. A. AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC). MANUAL OF STEEL CONSTRUCTION, ALLOWABLE STRESS DESIGN (ASD). B. AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM). ASTM A36: STRUCTURAL STEEL ASTM A53: PIPE, STEEL BLACK AND HOT DIPPED, ZINC-COATED WELDED AND SEAMLESS. ASTM A108: STEEL BARS, CARBON, COLD FINISHED, STANDARD QUALITY. ASTM A123: ZINC (HOT-DIPPED GALVANIZED) COATING ON IRON AND STEEL PRODUCTS. ASTM A307: CARBON STEEL BOLTS AND STUDS, 60,000 P.S.I. TENSILE STRENGTH. ASTM A325: HIGH-STRENGTH BOLT FOR STRUCTURAL STEEL JOINTS. ASTM A490: HEAT-TREATED, STRUCTURAL STEEL BOLTS, 150 (KSI) (1035MPA) TENSILE STRENGTH. ASTM A500: COLD-FORMED WELDED AND SEAMLESS CARBON STEEL STRUCTURAL TUBING IN ROUNDS AND SHAPES. ASTM A563: CARBON AND ALLOY STEEL NUTS. ASTM B695: COATINGS OF ZINC MECHANICALLY DEPOSITED ON IRON AND STEEL. ASTM F436: HARDENED STEEL WASHERS. ASTM F959: COMPRESSIBLE-WASHER-TYPE DIRECT TENSION INDICATOR FOR USE WITH STRUCTURAL FASTENERS. C. AMERICAN WELDING SOCIETY (AWS): AWS A5.1: COVERED CARBON STEEL ARC WELDING ELECTRODES. AWS A5.5: LOW ALLOY STEEL COVERED ARC WELDING ELECTRODES. AWS D1.1: STRUCTURAL WELDING CODE - STEEL. D. RESEARCH COUNCIL ON STRUCTURAL CONNECTIONS (RCSC): "SPECIFICATIONS FOR STRUCTURAL JOINTS USING ASTM A325 BOLTS OR ASTM A490 BOLTS." AS ENDORSED BY AISC. E. STEEL STRUCTURES PAINTING COUNCIL (SSPC): SSPC-SP3: POWER TOOL CLEANING. SSPC-PAINT 11: RED IRON OXIDE, ZINC CHROME, RAW LINSEED OIL OR ALKYD PAINT. 1.3 SUBMITTALS: A.SUBMIT THE FOLLOWING FOR APPROVAL: 1. FABRICATION AND ERECTION DRAWINGS SHOWING ALL DETAILS, CONNECTIONS, MATERIAL DESIGNATIONS, AND ALL TOP STEEL ELEVATIONS. B. WELDERS SHALL BE QUALIFIED AS PRESCRIBED IN AWS D1.1. PART 2 - PRODUCTS 2.1 STRUCTURAL STEEL: A. SHAPES, PLATES AND BARS SHALL CONFIRM TO ASTM A36. B. STRUCTURAL TUBING SHALL CONFIRM TO ASTM A500, GRADE B. STEEL PIPE SHALL CONFIRM TO ASTM A53, TYPE E OR S, GRADE B. 2.2 ANCHOR BOLTS: A. ANCHOR BOLTS SHALL CONFIRM TO ASTM A307 WITH HEAVY HEXAGONAL NUTS. 2.3 BOLTS: A. COMMON (MACHINE) BOLTS SHALL CONFIRM TO ASTM A307 GRADE A AND NUTS TO ASTM A563. ONE COMMON BOLT ASSEMBLY SHALL CONSIST OF A BOLT. A HEAVY HEX NUT AND A HARDENED WASHER. B. HIGH-STRENGTH BOLTS SHALL CONFORM TO ASTM A325; ONE HIGH STRENGTH BOLT ASSEMBLY SHALL CONSIST OF A HEAVY HEX STRUCTURAL BOLT, A HEAVY HEX NUT, A HARDENED WASHER CONFORMING TO ASTM F436. THE HARDENED WASHER SHALL BE INSTALLED AGAINST THE ELEMENT TURNED IN TIGHTENING. UNLESS NOTED OTHERWISE ON THE DRAWINGS, ALL CONNECTIONS SHALL BE BEARING TYPE CONNECTIONS. 2.4 WELDING ELECTRODES: 3.3 INSTALLATION: A. WELDING ELECTRODES SHALL COMPLY WITH AWS D1.1 USING A5.1 OR A5.5 E70XX AND SHALL BE COMPATIBLE WITH THE WELDING PROCESS SELECTED. 2.5 PRIMER: A. PRIMER SHALL BE RED OXIDE-CHROMATE PRIMER COMPLYING WITH SSPC PAINT SPECIFICATION NO. 11. B. STRUCTURAL FIELD WELDING SHALL BE DONE BY THE ELECTRIC SUBMERGED OR SHIELDED METAL ARC PROCESS. WELDED CONSTRUCTION SHALL COMPLY WITH AWS D1.1. A. INSTALLATION OF STRUCTURAL STEEL SHALL COMPLY WITH AISC "CODE OF STANDARD PRACTICE." G. PRIMER SHALL BE UNIFORMLY APPLIED WITHOUT RUNS, SAGS, SOLVENT BLISTERS, DRY SPRAY OR OTHER BLEMISHES. ALL BLEMISHES AND OTHER IRREGULARITIES SHALL BE REPAIRED OR REMOVED AND THE AREA RE-COATED. SPECIAL ATTENTION SHALL BE PAID TO CREVICES, WELD LINES, BOLT HEADS, CORNERS, EDGES, ETC., TO OBTAIN THE REQUIRED NOMINAL FILM THICKNESS. H. THE DRY FILM THICKNESS OF THE PRIMER SHALL BE 2.0 MILS. I.IF THE PRIMER IS DAMAGED BY WELDING OR PHYSICAL ABUSE, THE AREA SHALL BE TOUCHED UP AND REPAIRED. THE TOUCHUP PAINT SHALL BE COMPATIBLE WITH THE APPLIES PRIMER WITH MINIMUM DRY FILM THICKNESS OF 1.5 MILS. 1. PROVIDE BOLTS AND WASHERS OF TYPES AND SIZE REQUIRED FOR COMPLETION OF FIELD ERECTION. USE 3/4 INCH DIAMETER A325 BOLTS UNLESS NOTED OTHERWISE. 2. INSTALL HIGH STRENGTH THREADED FASTENERS IN ACCORDANCE WITH RCSC "SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR ASTM A490 BOLTS." 3. WELDED CONSTRUCTION SHALL COMPLY WITH AWS D1.1 FOR PROCEDURES, APPEARANCE, QUALITY OF WELD, AND METHODS USED IN CORRECTING WELDED WORK. 4. THE FABRICATOR SHALL FURNISH AND INSTALL ERECTION CLIPS FOR FIT-UP OF WELDED CONNECTIONS. 5. DOUBLE ANGLE MEMBERS SHALL HAVE WELDED FILLERS SPACED IN ACCORDANCE WITH CHAPTER E4 OF THE AISC-ASD SPECIFICATION. 6. GUSSET AND STIFFENER PLATES SHALL BE 3/8 INCH THICK MINIMUM. 3.2 PRIMING: A. STRUCTURAL STEEL SHALL BE PRIMED AS SPECIFIED HEREIN, UNLESS SHOWN OTHERWISE ON THE DRAWINGS. B. STRUCTURAL STEEL SURFACE PREPARATION SHALL CONFIRM TO SSPC-SP3, "POWER TOOL CLEANING." C. SURFACE PREPARATION AND PRIMER SHALL BE IN ACCORDANCE WITH AISC CODE OF STANDARD PRACTICE AS INCLUDED IN THE ASD MANUAL OF STEEL CONSTRUCTION. D. MATERIALS SHALL REMAIN CLOSED UNTIL REQUIRED FOR USE, MANUFACTURER'S POT-LIFE REQUIREMENTS SHALL BE STRICTLY ADHERED TO. E. PRIMER SHALL BE APPLIED TO DRY, CLEAN, PREPARED SURFACE AND UNDER FAVORABLE CONDITIONS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. UNLESS OTHERWISE RECOMMENDED BY THE MANUFACTURER PRIMING SHALL NOT BE DONE WHEN AMBIENT TEMPERATURE IS LESS THAN 50 DEGREE F. THE RELATIVE HUMIDITY IS MORE THAN 90 PERCENT, OR THE SURFACE TEMPERATURE IS LESS THAN 5 DEGREE F ABOVE THE DEW POINT. F. GENERALLY ALL PRIMER SHALL BE SPRAY APPLIED. BRUSH OR ROLLER APPLICATION SHALL BE RESTRICTED TO TOUCHUP AND TO AREAS NOT ACCESSIBLE BY SPRAY GUN. STRUCTURAL NOTES 1.0 GENERAL CONDITIONS 1.1 DESIGN AND CONSTRUCTION OF ALL WORK SHALL CONFORM TO THE IBC 2006 EDITION AND ALL OTHER APPLICABLE STATE CODES, ORDINANCES, AND REGULATIONS. IN CASE OF CONFLICT BETWEEN THE CODES, STANDARDS, AND REGULATIONS. SPECIFICATIONS, GENERAL NOTES AND/OR MANUFACTURER'S REQUIREMENTS. USE THE MOST STRINGENT PROVISION. 1.2 IT IS THE EXPRESS INTENT OF THE PARTIES INVOLVED IN THIS PROJECT THAT THE CONTRACTOR OR SUBCONTRACTOR OR INDEPENDENT CONTRACTOR OR THEIR RESPECTIVE EMPLOYEES SHALL EXCULPATE THE ARCHITECT, THE ENGINEER, THE CONSTRUCTION MANAGER, THE OWNER, AND THEIR AGENTS, FROM ANY LIABILITY WHATSOEVER AND HOLD THEM HARMLESS AGAINST LOSS, DAMAGES, LIABILITY OR ANY EXPENSE ARISING IN ANY MATTER FROM THE WRONGFUL OR NEGLIGENT ACT, OR FAILURE TO CARRY OUT THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS, OR THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES OR FAILURE TO CONFORM TO THE STATE SCAFFOLDING ACT IN CONNECTION WITH THE WORK. 1.3 DO NOT SCALE DRAWINGS. 1.4 VERIFY ALL EQUIPMENT MOUNTING DIMENSIONS PER MANUFACTURER DRAWINGS. 1.5 SUBMIT ONE SEPIA AND TWO PRINTS OF ALL STRUCTURAL SHOP DRAWINGS. MARKED UP SEPIA SHALL BE RETURNED. 1.6 DESIGN LOADS ARE: WIND SPEED SEISMIC ZONE SBC & UBC - 4 AND IBC - E SHELTER WEIGHT:WITHOUT EQUIPMENT WITH EQUIPMENT 2.0 STEEL 2.1 MEET OR EXCEED THE FOLLOWING CODES & STANDARDS (LATEST EDITION) EXCEPT AS NOTED: A. STRUCTURAL STEEL...AISC SPECIFICATION & CODE OF STANDARD PRACTICE -SHAPES AND PLATES...ASTM A572 -PLATES BENT OR COLD FORMED...ASTM A 283, GRADE C -PIPES...ASTM A 53, GRADE B -STRUCTURAL SHEETS, HOT ROLLED...ASTM A 510 -COLD FORMED STEEL TUBING...ASTM A 500 GRADE B -BOLTS, NUTS & WASHERS FOR ANCHOR BOLTS AND SECONDARY CONNECTIONS...ASTM A307 -ALL STEEL SHALL BE HOT-DIPPED GALVANIZED. B. WELDS...AWS E 70XX EXCEPTION IS TAKEN TO AISC CODE OF STANDARD PRACTICE PARAGRAPH 4.2.1 REGARDING OWNERS AND FABRICATOR'S RESPONSIBILITY FOR CONNECTION DESIGN AND DETAILING IS THE CONTRACTORS RESPONSIBILITY. ENGINEER'S REVIEW OF SHOP DRAWINGS IS FOR GENERAL CONSIDERATIONS ONLY AND DOES NOT CONSTITUTE AN ACCEPTANCE OF THESE RESPONSIBILITIES BY THE OWNER AND/OR ENGINEER. 3.0 FIBER REINFORCED PLASTIC 3.1 ALL FRP MATERIAL SHALL BE EXTREN SERIES 500 OR EQUIV. 3.2 ALL ADHESIVE SHALL BE PLEXUS METHACRYLATE ADHESIVE OR EQUIV. 3.3 ALL FRP CONNECTIONS SHALL BE FULL BONDED EACH SIDE WITH 3 8" PLATE AND MINIMUM (2) 3 3.4 ALL PANELS SHALL BE FULL BONDED W/ 3 8" PAN HEAD FRP SCREWS PER MEMBER. 8" PAN HEAD FRP SCREWS AT 12" O.C. 5,500lbs 7,500lbs 115 MPH 3 SEC EXP C 3. PROPERLY MARK AND MATCH-MARK MATERIALS FOR FIELD ASSEMBLY AND FOR IDENTIFICATION AS TO LOCATION FOR WHICH INTENDED. 4. FABRICATE AND DELIVER IN A SEQUENCE WHICH WILL EXPEDITE ERECTION AND MINIMIZE FIELD HANDLING OF MATERIALS. 5. WHERE FINISHING IS REQUIRED, COMPLETE THE ASSEMBLY, INCLUDING THE WELDING OF UNITS, BEFORE START OF FINISHING OPERATIONS. 6. PROVIDE FINISH SURFACE OF MEMBERS EXPOSED IN THE FINAL STRUCTURE FREE FROM MARKINGS, BURNS, AND OTHER DEFECTS. B. PROVIDE CONNECTIONS AS SPECIFIED HEREIN: F. PROVIDE TEMPORARY SHORING BRACING WITH CONNECTIONS OF SUFFICIENT STRENGTH TO BEAR IMPOSED LOADS. REMOVE TEMPORARY CONNECTIONS AND MEMBERS WHEN PERMANENT MEMBERS ARE IN PLACE AND THE FINAL CONNECTIONS HAVE BEEN MADE. G. ALIGN AND ADJUST MEMBERS, AND OTHER SURFACES WHICH WILL BE IN THE PERMANENT CONTACT, BEFORE ASSEMBLY. H. HIGH-STRENGTH BOLTS AS A MINIMUM, SHALL BE TIGHTENED TO A "SNUG TIGHT" CONDITION AS DEFINED IN THE LATEST AISC SPECIFICATION. ALL HIGH-STRENGTH BOLTS SPECIFIED ON THE DESIGN DRAWINGS TO BE USED IN PRETENSIONED OR SLIP-CRITICAL JOINTS SHALL BE TIGHTENED TO A BOLT TENSION NOT LESS THAN THAT GIVEN IN AISC TABLE J3.1. INSTALLATION SHALL BE BY ANY OF THE FOLLOWING METHODS: TURN-OF NUT METHOD, A DIRECT-TENSION-INDICATOR, TWIST-OFF-TYPE TENSION-CONTROL BOLT, CALIBRATED WRENCH, OR ALTERNATIVE DESIGN BOLT. 1. FABRICATE ITEMS OF STRUCTURAL STEEL IN ACCORDANCE WITH THE AISC-ASD SPECIFICATION, AND AS INDICATED ON THE APPROVED SHOP DRAWINGS. C. PROVIDE ANCHOR BOLTS AND OTHER CONNECTORS REQUIRED FOR SECURING STRUCTURAL STEEL TO ELEVATOR SHAFT WALLS AND OTHER IN-PLACE WORK. PROVIDE TEMPLATES AND OTHER DEVICES NECESSARY FOR PRESETTING BOLTS AND ANCHORS TO ACCURATE LOCATIONS. D. SPLICE MEMBERS ONLY WHERE INDICATED ON THE DRAWINGS. E. ANY GAS CUTTING TORCHES HAVE TO BE APPROVED IN WRITING BY THE PROJECT STRUCTURAL ENGINEER. GENERAL STEEL WORK NOTES: SNOW LOAD 300 PSF 6/14/21 FINAL CD'S NP 839612 CM IDL01003 IDL01003 1250 WEST USTICK ROAD MERIDIAN, ID 83646 161 Inverness Drive West 2nd floor Englewood, Colorado 80112 PREPARED FOR: REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: BU NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Tower Owner: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: A&E: at&t 2055 SOUTH STEARMAN DRIVE CHANDLER, AZ 85286 B RAD CENTER CHANGE04/23/21 A 4/07/21 PRELIMINARY CD'S C RAD CENTER CHANGE06/01/21 0 SUBMITTAL CD'S06/03/21 0A 6/14/21 SUBMITTAL CD'S TIM ALEX A N D E RSIGNED, EXPIRES, 28 FEB 2023 GENERAL NOTES GN-6 GENERAL ELECTRICAL NOTES: PART 1 - GENERAL 1.1 GENERAL CONDITIONS: D. CHEMICAL ELECTROLYTIC GROUNDING SYSTEM: A. CONTRACTOR SHALL INSPECT THE EXISTING SITE CONDITIONS PRIOR TO SUBMITTING BID. ANY QUESTIONS ARISING DURING THE BID PERIOD IN REGARDS TO THE CONTRACTORS FUNCTIONS, THE SCOPE OF WORK, OR ANY OTHER ISSUE RELATED TO THIS PROJECT SHALL BE BROUGHT UP DURING THE BID PERIOD WITH THE PROJECT MANAGER FOR CLARIFICATION, NOT AFTER THE CONTRACT HAS BEEN AWARDED. B. THE CONTRACTOR SHALL OBTAIN PERMITS, LICENSES, MAKE ALL DEPOSITS, AND PAY ALL FEES REQUIRED FOR THE CONSTRUCTION PERFORMANCE FOR THE WORK UNDER THIS SECTION. C. DRAWINGS SHOW THE GENERAL ARRANGEMENT OF ALL SYSTEMS AND COMPONENTS COVERED UNDER THIS SECTION. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS. DRAWING SHALL NOT BE SCALED TO DETERMINE DIMENSIONS. 1.2 LAWS, REGULATIONS, ORDINANCES, STATUTES AND CODES. A. ALL WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE, AND ALL APPLICABLE LOCAL LAWS, REGULATIONS, ORDINANCES, STATUTES AND CODES. CONDUIT BENDS SHALL BE THE RADIUS BEND FOR THE TRADE SIZE OF CONDUIT IN COMPLIANCE WITH THE LATEST EDITIONS OF NEC. 1.3 REFERENCES: A. THE PUBLICATIONS LISTED BELOW ARE PART OF THIS SPECIFICATION. EACH PUBLICATION SHALL BE THE LATEST REVISION AND ADDENDUM IN EFFECT ON THE DATE. THIS SPECIFICATION IS ISSUED FOR CONSTRUCTION UNLESS OTHERWISE NOTED. EXCEPT AS MODIFIED BY THE REQUIREMENT SPECIFIED HEREIN OR THE DETAILS OF THE DRAWINGS, WORK INCLUDED IN THIS SPECIFICATION SHALL CONFORM TO THE APPLICABLE PROVISION OF THESE PUBLICATIONS. 1. ANSI/IEEE (AMERICAN NATIONAL STANDARDS INSTITUTE) 2. ASTM (AMERICAN SOCIETY FOR TESTING AND MATERIALS) 3. ICE (INSULATED CABLE ENGINEERS ASSOCIATION) 4. NEMA (NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION) 5. NFPA (NATIONAL FIRE PROTECTION ASSOCIATION) 6. OSHA (OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION) 7. UL (UNDERWRITERS LABORATORIES. INC.) 8. AT&T GROUNDING AND BONDING STANDARDS TP-76416 1.4 SCOPE OF WORK: A. WORK UNDER THIS SECTION SHALL CONSIST OF FURNISHING ALL LABOR, MATERIAL, AND ASSOCIATED SERVICES REQUIRED TO COMPLETE REQUIRED CONSTRUCTION AND BE OPERATIONAL. B. ALL ELECTRICAL EQUIPMENT UNDER THIS CONTRACT SHALL BE PROPERLY TESTED, ADJUSTED, AND ALIGNED BY THE CONTRACTOR. C. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL EXCAVATING, DRAINING, TRENCHES, BACKFILLING, AND REMOVAL OF EXCESS DIRT. D. THE CONTRACTOR SHALL FURNISH TO THE OWNER WITH CERTIFICATES OF A FINAL INSPECTION AND APPROVAL FROM THE INSPECTION AUTHORITIES HAVING JURISDICTION. E. THE CONTRACTOR SHALL PREPARE A COMPLETE SET OF AS-BUILT DRAWINGS, DOCUMENT ALL WIRING EQUIPMENT CONDITIONS, AND CHANGES WHILE COMPLETING THIS CONTRACT. THE AS-BUILT DRAWINGS SHALL BE SUBMITTED AT COMPLETION OF THE PROJECT. PART 2 - PRODUCTS 2.1 GENERAL: A. ALL MATERIALS AND EQUIPMENT SHALL BE UL LISTED, NEW, AND FREE FROM DEFECTS. B. ALL ITEMS OF MATERIALS AND EQUIPMENT SHALL BE ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION AS SUITABLE FOR THE USE INTENDED. C. ALL EQUIPMENT SHALL BEAR THE UNDERWRITERS LABORATORIES LABEL OF APPROVAL, AND SHALL CONFORM TO REQUIREMENT OF THE NATIONAL ELECTRICAL CODE. D. ALL OVERCURRENT DEVICES SHALL HAVE AN INTERRUPTING CURRENT RATING THAT SHALL BE GREATER THAN THE SHORT CIRCUIT CURRENT TO WHICH THEY ARE SUBJECTED, 10,000 AIC MINIMUM. VERIFY AVAILABLE SHORT CIRCUIT CURRENT DOES NOT EXCEED THE RATING OF ELECTRICAL EQUIPMENT IN ACCORDANCE WITH ARTICLE 110.24 NEC OR THE MOST CURRENT ADOPTED CODE PER THE GOVERNING JURISDICTION. 2.2 MATERIALS AND EQUIPMENT: A. CONDUIT: 1. RIGID METAL CONDUIT (RMC) SHALL BE HOT-DIPPED GALVANIZED INSIDE AND OUTSIDE INCLUDING ENDS AND THREADS AND ENAMELED OR LACQUERED INSIDE IN ADDITION TO GALVANIZING. 2. LIQUIDTIGHT FLEXIBLE METAL CONDUIT SHALL BE UL LISTED. 3. CONDUIT CLAMPS, STRAPS AND SUPPORTS SHALL BE STEEL OR MALLEABLE IRON. ALL FITTINGS SHALL BE COMPRESSION AND CONCRETE TIGHT TYPE. GROUNDING BUSHINGS WITH INSULATED THROATS SHALL BE INSTALLED ON ALL CONDUIT TERMINATIONS. 4. NONMETALLIC CONDUIT AND FITTINGS SHALL BE SCHEDULE 40 PVC. INSTALL USING SOLVENT-CEMENT-TYPE JOINTS AS RECOMMENDED BY THE MANUFACTURER. B. CONDUCTORS AND CABLE: 1. CONDUCTORS AND CABLE SHALL BE FLAME-RETARDANT, MOISTURE AND HEAT RESISTANT THERMOPLASTIC, SINGLE CONDUCTOR, COPPER, TYPE THHN/THWN-2, 600 VOLT, SIZE AS INDICATED, #12 AWG SHALL BE THE MINIMUM SIZE CONDUCTOR USED. 2. #10 AWG AND SMALLER CONDUCTOR SHALL BE SOLID OR STRANDED AND #8 AWG AND LARGER CONDUCTORS SHALL BE STRANDED. 3. SOLDERLESS, COMPRESSION-TYPE CONNECTORS SHALL BE USED FOR TERMINATION OF ALL STRANDED CONDUCTORS. 4. STRAIN-RELIEF SUPPORTS GRIPS SHALL BE HUBBELL KELLEMS OR APPROVED EQUAL. CABLES SHALL BE SUPPORTED IN ACCORDANCE WITH THE NEC AND CABLE MANUFACTURER'S RECOMMENDATIONS. ALL CONDUCTORS SHALL BE TAGGED AT BOTH ENDS OF THE CONDUCTOR, AT ALL PULL 5. BOXES, J-BOXES, EQUIPMENT AND CABINETS AND SHALL BE IDENTIFIED WITH APPROVED PLASTIC TAGS (ACTION CRAFT, BRADY, OR APPROVED EQUAL). C. DISCONNECT SWITCHES: 1. DISCONNECT SWITCHES SHALL BE HEAVY DUTY, DEAD-FRONT, QUICK-MAKE, QUICK-BREAK, EXTERNALLY OPERABLE, HANDLE LOCKABLE AND INTERLOCK WITH COVER IN CLOSED POSITION, RATING AS INDICATED, UL LABELED FURNISHED IN NEMA 3R ENCLOSURE, SQUARE-D OR ENGINEERED APPROVED EQUAL. 2. PROVIDE RIGID PVC SCHEDULE 80 CONDUITS FOR ALL RISERS, RMC OTHERWISE NOTED. EMT MAY BE INSTALLED FOR EXTERIOR CONDUITS WHERE NOT SUBJECT TO PHYSICAL DAMAGE. 3. INSTALL SCH. 40 PVC CONDUIT WITH A MINIMUM COVER OF 24" UNDER ROADWAYS, PARKING LOTS, STREETS, AND ALLEYS. CONDUIT SHALL HAVE A MINIMUM COVER OF 18" IN ALL OTHER NON-TRAFFIC APPLICATIONS (REFER TO 2011 NEC, TABLE 300.5). 4. USE GALVANIZED FLEXIBLE STEEL CONDUIT WHERE DIRECT CONNECTION TO EQUIPMENT WITH MOVEMENT, VIBRATION, OR FOR EASE OF MAINTENANCE. USE LIQUID TIGHT, FLEXIBLE METAL CONDUIT FOR OUTDOOR APPLICATIONS. INSTALL GALVANIZED FLEXIBLE STEEL CONDUIT AT ALL POINTS OF CONNECTION TO EQUIPMENT MOUNTED ON SUPPORT TO ALLOW FOR EXPANSION AND CONTRACTION. 5. A RUN OF CONDUIT BETWEEN BOXES OR EQUIPMENT SHALL NOT CONTAIN MORE THAN THE EQUIVALENT OF THREE QUARTER-BENDS. CONDUIT BEND SHALL BE MADE WITH THE UL LISTED BENDER OR FACTORY 90 DEGREE ELBOWS MAY BE USED. 6. FIELD FABRICATED CONDUITS SHALL BE CUT SQUARE WITH A CONDUIT CUTTING TOOL AND REAMED TO PROVIDE A SMOOTH INSIDE SURFACE. 7. PROVIDE INSULATED GROUNDING BUSHING FOR ALL CONDUITS. 8. CONTRACTOR IS RESPONSIBLE FOR PROTECTING ALL CONDUITS DURING CONSTRUCTION. TEMPORARY OPENINGS IN THE CONDUIT SYSTEM SHALL BE PLUGGED OR CAPPED TO PREVENT ENTRANCE OF MOISTURE OR FOREIGN MATTER. CONTRACTOR SHALL REPLACE ANY CONDUITS CONTAINING FOREIGN MATERIALS THAT CANNOT BE REMOVED. 9. ALL CONDUITS SHALL BE SWABBED CLEAN BY PULLING AN APPROPRIATE SIZE MANDREL THROUGH THE CONDUIT BEFORE INSTALLATION OF CONDUCTORS OR CABLES. CONDUIT SHALL BE FREE OF DIRT AND DEBRIS. 10. INSTALL PULL STRINGS IN ALL CLEAN EMPTY CONDUITS. IDENTIFY PULL STRINGS AT EACH END. 11. INSTALL 2" HIGHLY VISIBLE AND DETECTABLE TAPE 12" ABOVE ALL UNDERGROUND CONDUITS AND CONDUCTORS. 12. CONDUITS SHALL BE INSTALLED IN SUCH A MANNER AS TO INSURE AGAINST COLLECTION OF TRAPPED CONDENSATION. 13. PROVIDE CORE DRILLING AS NECESSARY FOR PENETRATIONS TO ALLOW FOR RACEWAYS AND CABLES TO BE ROUTED THROUGH THE BUILDING. DO NOT PENETRATE STRUCTURAL MEMBERS. SLEEVES AND/OR PENETRATIONS IN FIRE RATED CONSTRUCTION SHALL BE EFFECTIVELY SEALED WITH FIRE RATED MATERIAL WHICH SHALL MAINTAIN THE FIRE RATING OF THE WALL OR STRUCTURE. FIRE STOPS AT FLOOR PENETRATIONS SHALL PREVENT PASSAGE OF WATER, SMOKE, FIRE, AND FUMES. ALL MATERIAL SHALL BE UL APPROVED FOR THIS PURPOSE. 1. THE CONTRACTOR SHALL PROVIDE OTHER MATERIALS, THOUGH NOT SPECIFICALLY DESCRIBED, WHICH ARE REQUIRED FOR A COMPLETELY OPERATIONAL SYSTEM AND PROPER INSTALLATION OF THE WORK. 2. PROVIDE PULL BOXES AND JUNCTION BOXES WHERE SHOWN OR REQUIRED BY NEC. G. PANELS AND LOAD CENTERS: 1. ALL PANEL DIRECTORIES SHALL BE TYPEWRITTEN. PART 3 - EXECUTION 3.1 GENERAL: A. ALL MATERIAL AND EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. B. B. EQUIPMENT SHALL BE TIGHTLY COVERED AND PROTECTED AGAINST DIRT OR WATER, AND AGAINST CHEMICAL OR MECHANICAL INJURY DURING INSTALLATION AND CONSTRUCTION PERIODS. 3.2 LABOR AND WORKMANSHIP: A. ALL LABOR FOR THE INSTALLATION OF MATERIALS AND EQUIPMENT FURNISHED FOR THE ELECTRICAL SYSTEM SHALL BE INSTALLED BY EXPERIENCED WIREMEN, IN A NEAT AND WORKMAN-LIKE MANNER. B. ALL ELECTRICAL EQUIPMENT SHALL BE ADJUSTED, ALIGNED AND TESTED BY THE CONTRACTOR AS REQUIRED TO PRODUCE THE INTENDED PERFORMANCE. C. UPON COMPLETION OF WORK, THE CONTRACTOR SHALL THOROUGHLY CLEAN ALL EXPOSED EQUIPMENT, REMOVE ALL LABELS AND ANY DEBRIS, CRATING OR CARTONS AND LEAVE THE INSTALLATION FINISHED AND READY FOR OPERATION. 3.3 COORDINATION: A. THE CONTRACTOR SHALL COORDINATE THE INSTALLATION OF ELECTRICAL ITEMS WITH THE OWNER-FURNISHED EQUIPMENT DELIVERY SCHEDULE TO PREVENT UNNECESSARY DELAYS IN THE TOTAL WORK. 3.4 INSTALLATION: A. CONDUIT: 1. ALL ELECTRICAL WIRING SHALL BE INSTALLED IN CONDUIT AS SPECIFIED. NO CONDUIT OR TUBING OF LESS THAN 3/4 INCH TRADE SIZE. 1. INSTALL CHEMICAL GROUNDING AS REQUIRED. THE SYSTEM SHALL BE ELECTROLYTIC MAINTENANCE FREE ELECTRODE CONSISTING OF RODS WITH A MINIMUM #2 AWG CU EXOTHERMALLY WELDED PIGTAIL, PROTECTIVE BOXES, AND BACKFILL MATERIAL. MANUFACTURER SHALL BE LYNCOLE XIT GROUNDING ROD TYPES K2-(*)CS OR K2L-(*)CS (*) LENGTH AS REQUIRED. 2. GROUND ACCESS BOX SHALL BE A POLYPLASTIC BOX FOR NON-TRAFFIC APPLICATIONS, INCLUDING BOLT DOWN FLUSH COVER WITH "BREATHER" HOLES, XIT MODEL #XB-22. ALL DISCONNECT SWITCHES AND CONTROLLING DEVICES SHALL BE PROVIDED WITH ENGRAVED LAMICOID NAMEPLATES INDICATING EQUIPMENT CONTROLLED, BRANCH CIRCUITS ID NUMBERING, AND THE ELECTRICAL POWER SOURCE. 3. BACKFILL MATERIAL SHALL BE LYNCONITE AND LYNCOLE GROUNDING GRAVEL. E. SYSTEM GROUNDING: 1. ALL GROUNDING COMPONENTS SHALL BE TINNED AND GROUNDING CONDUCTOR SHALL BE #2 AWG BARE, SOLID, TINNED, COPPER. ABOVE GRADE GROUNDING CONDUCTORS SHALL BE INSULATED WHERE NOTED. 2. GROUNDING BUSES SHALL BE BARE, TINNED, ANNEALED COPPER BARS OF RECTANGULAR CROSS SECTION. STANDARD BUS BARS MGB, SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR. THEY SHALL NOT BE FABRICATED OR MODIFIED IN THE FIELD. ALL GROUNDING BUSES SHALL BE IDENTIFIED WITH MINIMUM 3/4" LETTERS BY WAY OF STENCILING OR DESIGNATION PLATE. 3. CONNECTORS SHALL BE HIGH-CONDUCTIVITY, HEAVY DUTY, LISTED AND LABELED AS GROUNDING CONNECTORS FOR THE MATERIALS USED. USE TWO-HOLE COMPRESSION LUGS WITH CLEAR HEAT SHRINK FOR MECHANICAL CONNECTIONS. USE TWO-HOLE COMPRESSION LUGS WITH INSPECTION WINDOW AND CLEAR HEAT SHRINK. 4. EXOTHERMIC WELDED CONNECTIONS SHALL BE PROVIDED IN KIT FORM AND SELECTED FOR THE SPECIFIC TYPES, SIZES, AND COMBINATIONS OF CONDUCTORS AND OTHER ITEMS TO BE CONNECTED. 5. GROUND RODS SHALL BE ERICO #615800, COPPER-CLAD STEEL WITH HIGH-STRENGTH STEEL CORE AND ELECTROLYTIC-GRADE COPPER OUTER SHEATH, MOLTEN WELDED TO CORE, 5/8"x10'-0". ALL GROUNDING RODS SHALL BE INSTALLED WITH INSPECTION SLEEVES. 6. INSTALL AN EQUIPMENT GROUNDING CONDUCTOR IN ALL CONDUITS IN COMPLIANCE WITH THE AT&T SPECIFICATIONS AND NEC. THE EQUIPMENT GROUNDING CONDUCTORS SHALL BE BONDED AT ALL JUNCTION BOXES, PULLBOXES, DISCONNECT SWITCHES, STARTERS, AND EQUIPMENT CABINETS. F. OTHER MATERIALS: B.CONDUCTORS AND CABLE: 1. ALL POWER WIRING SHALL BE COLOR CODED AS FOLLOWS: DESCRIPTION PHASE A PHASE B PHASE C NEUTRAL GROUNDING BLACK RED BLUE WHITE GREEN 2. SPLICES SHALL BE MADE ONLY AT OUTLETS, JUNCTION BOXES, OR ACCESSIBLE RACEWAY CONDUITS APPROVED FOR THIS PURPOSE. 3. PULLING LUBRICANTS SHALL BE UL APPROVED. CONTRACTOR SHALL USE NYLON OR HEMP ROPE FOR PULLING CONDUCTOR OR CABLES INTO THE CONDUIT. 4. CABLES SHALL BE NEATLY TRAINED, WITHOUT INTERLACING, AND BE OF SUFFICIENT LENGTH IN ALL BOXES & EQUIPMENT TO PERMIT MAKING A NEAT ARRANGEMENT. CABLES SHALL BE SECURED IN A MANNER TO AVOID TENSION ON CONDUCTORS OR TERMINALS. CONDUCTORS SHALL BE PROTECTED FROM MECHANICAL INJURY AND MOISTURE. SHARP BENDS OVER CONDUIT BUSHINGS IS PROHIBITED. DAMAGED CABLES SHALL BE REMOVED AND REPLACED AT THE CONTRACTOR'S EXPENSE. C.DISCONNECT SWITCHES: 1. INSTALL DISCONNECT SWITCHES LEVEL AND PLUMB. CONNECT TO WIRING SYSTEM AND GROUNDING SYSTEM AS INDICATED. D.GROUNDING: 1. ALL METALLIC PARTS OF ELECTRICAL EQUIPMENT WHICH DO NOT CARRY CURRENT SHALL BE GROUNDED IN ACCORDANCE WITH THE REQUIREMENTS OF THE BUILDING MANUFACTURER, AT&T GROUNDING AND BONDING STANDARDS TP-76416, ND-00135, AND THE NATIONAL ELECTRICAL CODE. 2. PROVIDE ELECTRICAL GROUNDING AND BONDING SYSTEM INDICATED WITH ASSEMBLY OF MATERIALS, INCLUDING GROUNDING ELECTRODES, BONDING JUMPERS AND ADDITIONAL ACCESSORIES AS REQUIRED FOR A COMPLETE INSTALLATION. 3. ALL GROUNDING CONDUCTORS SHALL PROVIDE A STRAIGHT DOWNWARD PATH TO GROUND WITH GRADUAL BEND AS REQUIRED. GROUNDING CONDUCTORS SHALL NOT BE LOOPED OR SHARPLY BENT. ROUTE GROUNDING CONNECTIONS AND CONDUCTORS TO GROUND IN THE SHORTEST AND STRAIGHTEST PATHS POSSIBLE TO MINIMIZE TRANSIENT VOLTAGE RISES. BUILDINGS AND/OR NEW TOWERS GREATER THAN 75 FEET IN HEIGHT AND WHERE THE MAIN 4. GROUNDING CONDUCTORS ARE REQUIRED TO BE ROUTED TO GRADE, THE CONTRACTOR SHALL ROUTE TWO GROUNDING CONDUCTORS FROM THE ROOFTOP, TOWERS, AND WATER TOWERS GROUND RING, TO THE EXISTING GROUNDING SYSTEM, THE GROUNDING CONDUCTORS SHALL NOT BE SMALLER THAN #2 AWG COPPER. ROOFTOP GROUND RING SHALL BE BONDED TO THE EXISTING GROUNDING SYSTEM, THE BUILDING STEEL COLUMNS, LIGHTNING PROTECTION SYSTEM, AND BUILDING MAIN WATER LINE (FERROUS OR NONFERROUS METAL PIPING ONLY). SEE STANDARD 6.3.2.2. 5. TIGHTEN GROUNDING AND BONDING CONNECTORS, INCLUDING SCREWS AND BOLTS, IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED TORQUE TIGHTENING VALUES FOR CONNECTORS AND BOLTS. WHERE MANUFACTURER'S TORQUING REQUIREMENTS ARE NOT AVAILABLE, TIGHTEN CONNECTIONS TO COMPLY WITH TIGHTENING TORQUE VALUES SPECIFIED IN UL TO ASSURE PERMANENT AND EFFECTIVE GROUNDING. CONTRACTOR SHALL VERIFY THE LOCATIONS OF GROUNDING TIE-IN-POINTS TO THE EXISTING 6. ALL UNDERGROUND GROUNDING CONNECTIONS SHALL BE MADE BY THE GROUNDING SYSTEM. EXOTHERMIC WELD PROCESS AND INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. 7. ALL GROUNDING CONNECTIONS SHALL BE INSPECTED FOR TIGHTNESS. EXOTHERMIC WELDED CONNECTIONS SHALL BE APPROVED BY THE INSPECTOR HAVING JURISDICTION BEFORE BEING PERMANENTLY CONCEALED. 8. APPLY CORROSION-RESISTANCE FINISH TO FIELD CONNECTIONS AND PLACES WHERE FACTORY APPLIED PROTECTIVE COATINGS HAVE BEEN DESTROYED. 9. A SEPARATE, CONTINUOUS, INSULATED EQUIPMENT GROUNDING CONDUCTOR SHALL BE INSTALLED IN ALL FEEDER AND BRANCH CIRCUITS. 10. BOND ALL INSULATED GROUNDING BUSHINGS WITH A BARE 6 AWG GROUNDING CONDUCTOR TO A GROUND BUS. 11. DIRECT BURIED GROUNDING CONDUCTORS SHALL BE INSTALLED AT A NOMINAL DEPTH OF 36" MINIMUM BELOW GRADE, OR 6" BELOW THE FROST LINE, USE THE GREATER OF THE TWO DISTANCES. 12. ALL GROUNDING CONDUCTORS EMBEDDED IN OR PENETRATING CONCRETE SHALL BE INSTALLED IN SCHEDULE 40 PVC CONDUIT. 13. THE INSTALLATION OF CHEMICAL ELECTROLYTIC GROUNDING SYSTEM IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. REMOVE SEALING TAPE FROM LEACHING AND BREATHER HOLES. INSTALL PROTECTIVE BOX FLUSH WITH GRADE. 14. DRIVE GROUND RODS UNTIL TOPS ARE A MINIMUM DISTANCE OF 36" DEPTH OR 6" BELOW FROST LINE, USING THE GREATER OF THE TWO DISTANCES. 15. IF COAX ON THE ICE BRIDGE IS MORE THAN 6 FT. FROM THE GROUND BAR AT THE BASE OF THE TOWER, A SECOND GROUND BAR WILL BE NEEDED AT THE END OF THE ICE BRIDGE, TO GROUND THE COAX CABLE GROUNDING KITS AND IN-LINE ARRESTORS 16. CONTRACTOR SHALL REPAIR, AND/OR REPLACE, EXISTING GROUNDING SYSTEM COMPONENTS DAMAGED DURING CONSTRUCTION AT THE CONTRACTORS EXPENSE. 3.5 ACCEPTANCE TESTING A. CERTIFIED PERSONNEL USING CERTIFIED EQUIPMENT SHALL PERFORM REQUIRED TESTS AND SUBMIT WRITTEN TEST REPORTS UPON COMPLETION. B. WHEN MATERIAL AND/OR WORKMANSHIP IS FOUND NOT TO COMPLY WITH THE SPECIFIED REQUIREMENTS, THE NON-COMPLYING ITEMS SHALL BE REMOVED FROM THE PROJECT SITE AND REPLACED WITH ITEMS COMPLYING WITH THE SPECIFIED REQUIREMENTS PROMPTLY AFTER RECEIPT OF NOTICE FOR NON-COMPLIANCE. C. TEST PROCEDURES; 1. ALL FEEDERS SHALL HAVE INSULATION TESTED AFTER INSTALLATION, BEFORE CONNECTION TO DEVICES. THE CONDUCTORS SHALL TEST FREE FROM SHORT CIRCUITS AND GROUNDS. TESTING SHALL BE FOR ONE MINUTE USING 1000V DC. PROVIDE WRITTEN DOCUMENTATION FOR ALL TEST RESULTS. 2. PRIOR TO ENERGIZING CIRCUITRY, TEST WIRING DEVICES FOR ELECTRICAL CONTINUITY AND PROPER POLARITY CONNECTIONS. 3. MEASURE AND RECORD VOLTAGES BETWEEN PHASES AND BETWEEN PHASE CONDUCTORS AND NEUTRALS. SUBMIT A REPORT OF MAXIMUM AND MINIMUM VOLTAGES 4. PERFORM GROUNDING TEST TO MEASURE GROUNDING RESISTANCE OF GROUNDING SYSTEM USING THE IEEE STANDARD 3-POINT "FALL-OF-POTENTIAL" METHOD. PROVIDE PLOTTED TEST VALUES AND LOCATION SKETCH. NOTIFY THE ENGINEER IMMEDIATELY IF MEASURED VALUE IS OVER 5 OHMS. 208/240/120 VOLT SYSTEMS 6/14/21 FINAL CD'S NP 839612 CM IDL01003 IDL01003 1250 WEST USTICK ROAD MERIDIAN, ID 83646 161 Inverness Drive West 2nd floor Englewood, Colorado 80112 PREPARED FOR: REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: BU NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Tower Owner: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: A&E: at&t 2055 SOUTH STEARMAN DRIVE CHANDLER, AZ 85286 B RAD CENTER CHANGE04/23/21 A 4/07/21 PRELIMINARY CD'S C RAD CENTER CHANGE06/01/21 0 SUBMITTAL CD'S06/03/21 0A 6/14/21 SUBMITTAL CD'S TIM ALEX A N D E RSIGNED, EXPIRES, 28 FEB 2023 SITE SIGNAGE GN-72GATE SIGN 1 RADIO FREQUENCY INFORMATION SIGN 6 DOOR SIGN INFORMATION Contact AT&T Mobility at _____________ and follow their instructions prior to performing any maintenance or repairs closer than 3 feet from the antennas. This is AT&T Mobility site _____________ AT&T Mobility INFORMATION INFORMACION COMBUSTIBLE FLAMMABLE NO SMOKING 1 2 0DIESEL 1 4 0 PROPANE Posted in accordance with Federal Communications Commission rules on antenna tower registration 47CFR 17.4 (g). NO TRESPASSING 5 FUEL STORAGE SIGN 4 FCC TOWER REG. (ASRN)3 NO TRESPASSING SIGN X X XXXXXXXX X XXX 6/14/21 FINAL CD'S NP 839612 CM IDL01003 IDL01003 1250 WEST USTICK ROAD MERIDIAN, ID 83646 161 Inverness Drive West 2nd floor Englewood, Colorado 80112 PREPARED FOR: REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: BU NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Tower Owner: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: A&E: at&t 2055 SOUTH STEARMAN DRIVE CHANDLER, AZ 85286 B RAD CENTER CHANGE04/23/21 A 4/07/21 PRELIMINARY CD'S C RAD CENTER CHANGE06/01/21 0 SUBMITTAL CD'S06/03/21 0A 6/14/21 SUBMITTAL CD'S TIM ALEX A N D E RSIGNED, EXPIRES, 28 FEB 2023 OVERALL SITE PLAN A-1 ALL PROPERTY BOUNDARIES, ORIENTATION OF TRUE NORTH AND STREET HALF-WIDTHS HAVE BEEN OBTAINED FROM A TAX PARCEL MAP AND EXISTING DRAWINGS AND ARE APPROXIMATE. THIS IS NOT A SITE SURVEY SITE TYPE: MONOPOLE/WIC A-2 1 SCALE: OVERALL SITE PLAN 1 1"=30'-0" (FULL SIZE) 1"=60'-0" (11x17)30'15'0 30' A.P.N. R9532190560 SECTOR " "AC B A-4.1 1/2 A-4.2 1/2 (P) AT&T EQUIPMENT LEASE AREA: 15'-0"X20'-0" (E) BUILDING (TYP.) W USTICK RD (E) PARKING AREA X X X X X X X X X X X X X X X X XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX X X X X X X X X X X XXXXXX X X X X X X X X X 6/14/21 FINAL CD'S NP 839612 CM IDL01003 IDL01003 1250 WEST USTICK ROAD MERIDIAN, ID 83646 161 Inverness Drive West 2nd floor Englewood, Colorado 80112 PREPARED FOR: REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: BU NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Tower Owner: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: A&E: at&t 2055 SOUTH STEARMAN DRIVE CHANDLER, AZ 85286 B RAD CENTER CHANGE04/23/21 A 4/07/21 PRELIMINARY CD'S C RAD CENTER CHANGE06/01/21 0 SUBMITTAL CD'S06/03/21 0A 6/14/21 SUBMITTAL CD'S TIM ALEX A N D E RSIGNED, EXPIRES, 28 FEB 2023 EXISTING COMPOUND PLAN A-2 SITE TYPE: MONOPOLE/WIC SCALE: EXISTING COMPOUND PLAN1 1/4"=1'-0" (FULL SIZE) 1/8"=1'-0" (11x17)4'3'2'1'0 4' (E) 150'-0" MONOPOLE (E) FENCE (E) FENCE GATE (E) UTILITY FRAME BY OTHERS (E) LEASE AREA BY OTHERS (E) ICE BRIDGE BY OTHERS (E) EQUIPMENT SHELTER BY OTHERS (E) ICE BRIDGE BY OTHERS 19'-0" (E) 20'X20' CONCRETE PAD (E) UTILITY VAULT (E) PAD MOUNTED TRANSFORMER 20'-0"20'-0"29'-0"29'-0" X X X X X X X X X X X X X X X X XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX X X X X X X X X X X XXXXXX X X X X X X X X X XXXXXXXXXXXXXXXXX X X X X X X X X 6/14/21 FINAL CD'S NP 839612 CM IDL01003 IDL01003 1250 WEST USTICK ROAD MERIDIAN, ID 83646 161 Inverness Drive West 2nd floor Englewood, Colorado 80112 PREPARED FOR: REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: BU NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Tower Owner: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: A&E: at&t 2055 SOUTH STEARMAN DRIVE CHANDLER, AZ 85286 B RAD CENTER CHANGE04/23/21 A 4/07/21 PRELIMINARY CD'S C RAD CENTER CHANGE06/01/21 0 SUBMITTAL CD'S06/03/21 0A 6/14/21 SUBMITTAL CD'S TIM ALEX A N D E RSIGNED, EXPIRES, 28 FEB 2023 PROPOSED COMPOUND PLAN A-2.1 SITE TYPE: MONOPOLE/WIC SCALE: PROPOSED COMPOUND PLAN1 1/4"=1'-0" (FULL SIZE) 1/8"=1'-0" (11x17)4'3'2'1'0 4' (P) AT&T 8'-0"x8'-0" WALK-IN CABINET (SEE SHEET A-2.2 FOR DETAILS) (P) AT&T 30KW AC DIESEL GENERATOR ON 4'-0"X9'-0" CONCRETE PAD (P) AT&T UTILITY FRAME W/ ELECTRICAL EQUIPMENT (P) AT&T 19'-0" ICE BRIDGE (P) AT&T 15'-0"X20'-0" LEASE AREA (E) 150'-0" MONOPOLE (E) FENCE (E) FENCE GATE (E) UTILITY FRAME BY OTHERS (E) LEASE AREA BY OTHERS (E) ICE BRIDGE BY OTHERS (E) EQUIPMENT SHELTER BY OTHERS (E) ICE BRIDGE BY OTHERS 19'-0" (E) 20'X20' CONCRETE PAD (E) UTILITY VAULT (E) PAD MOUNTED TRANSFORMER 20'-0"20'-0"29'-0"29'-0"15'-0"20'-0" XXXXX X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 6/14/21 FINAL CD'S NP 839612 CM IDL01003 IDL01003 1250 WEST USTICK ROAD MERIDIAN, ID 83646 161 Inverness Drive West 2nd floor Englewood, Colorado 80112 PREPARED FOR: REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: BU NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Tower Owner: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: A&E: at&t 2055 SOUTH STEARMAN DRIVE CHANDLER, AZ 85286 B RAD CENTER CHANGE04/23/21 A 4/07/21 PRELIMINARY CD'S C RAD CENTER CHANGE06/01/21 0 SUBMITTAL CD'S06/03/21 0A 6/14/21 SUBMITTAL CD'S TIM ALEX A N D E RSIGNED, EXPIRES, 28 FEB 2023 INTERIOR WIC LAYOUT A-2.2 SITE TYPE: MONOPOLE/WIC SCALE: INTERIOR WIC LAYOUT1 1"=1'-0" (FULL SIZE) 1/2"=1'-0" (11x17)1'06"1' (P) (6) DC TRUNKS & (3) FIBER TRUNKS (P) 30KW AC DIESEL GENERATOR ON 4'-0"X9'-0" CONCRETE PAD (P) UTILITY H-FRAME (P) ELECTRICAL METER AND MAIN BREAKER W/ GFCI OUTLET (P) 19'-0" ICE BRIDGE (P) AT&T 8'-0" X 8'-0" WALK IN CABINET (P) RADIO RACK (P) TRANSPORT RACK (P) POWER PLANT RACK W/ (3) STRINGS OF BATTERIES (P) CIENA (P) CAMLOCK GENERATOR INTERFACE (P) 200A 30 CIRCUIT LOAD CENTER / AUTOMATIC TRANSFER SWITCH (P) HVAC (P) (2) DC12s 15'-0"16'-6"3'-0"6" 1'-0" (P) FENCING TO CONNECT TO EXISTING (MOVE SIGNAGE AS NEEDED) 3'-0"3'-0"3'-7"3'-2" 6/14/21 FINAL CD'S NP 839612 CM IDL01003 IDL01003 1250 WEST USTICK ROAD MERIDIAN, ID 83646 161 Inverness Drive West 2nd floor Englewood, Colorado 80112 PREPARED FOR: REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: BU NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Tower Owner: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: A&E: at&t 2055 SOUTH STEARMAN DRIVE CHANDLER, AZ 85286 B RAD CENTER CHANGE04/23/21 A 4/07/21 PRELIMINARY CD'S C RAD CENTER CHANGE06/01/21 0 SUBMITTAL CD'S06/03/21 0A 6/14/21 SUBMITTAL CD'S TIM ALEX A N D E RSIGNED, EXPIRES, 28 FEB 2023 ANTENNA PLAN & DETAILS A-3 SITE TYPE: MONOPOLE/WIC SCALE: RF SCHEDULE2NOT TO SCALESCALE: COMMSCOPE - NNH4-65C-R6-V34NOT TO SCALE RF CONNECTORS, TYP LENGTH:96.0" WIDTH:19.6" DEPTH:7.8" WEIGHT:102.1 lbs. SCALE: ANTENNA PLAN1 1/2"=1'-0" (FULL SIZE) 1/4"=1'-0" (11x17)2'2'1'0SCALE: SITEPRO1 VFA10-HD3L4NP ANTENNA FRAME DETAIL - ANT 159963NOT TO SCALE AC(P) 150'-0" MONOPOLE (P) (2) AT&T ANTENNAS PER SECTOR FOR A TOTAL OF (6) (P) (1) RAYCAP DC9 PER SECTOR FOR A TOTAL OF (3) (P) (5) AT&T RRHs PER SECTOR FOR A TOTAL OF (15) (STACKED) 3'-4" 10'-0" NOTE: OTHER SECTORS REMOVED FOR CLARITY. 12" TO 45" DIAMETER POLE 3" 4 1/8" 1 1/4" A B UPPER 3 1/8" 1 1/4" C A LOWER NOTES: 42 27/32" 31 21/32" 2. USE HOLE "A" IN UPPER BRACKET AND +2/(&,1/2:(5%5$&.(7)25ƒ 3. USE HOLE "B" IN UPPER BRACKET AND +2/(&,1/2:(5%5$&.(7)25ƒ 1. USE HOLE "A" IN UPPER AND LOWER BRACKETS FOR STRAIGHT LEGS. 40"40"40" 40"VARIABLE 40"C10'-6" (P) SITEPRO1 VFA10-HD3L4NP SECTOR FRAME (3) TOTAL POSITION TECHSECTOR ANTENNA RRH AZIMUTH 1ALPHA 2 3 4 ALPHA ALPHA ALPHA 1 2 3 BETA 4 BETA BETA BETA 1 2 3 GAMMA 4 GAMMA GAMMA GAMMA ANTENNA DIMS (HxWxD) - - - ---- ---- ---- 90 210 330 --96X19.6X7.8NNH4-65C-R6-V3 --96X19.6X7.8NNH4-65C-R6-V3- --96X19.6X7.8NNH4-65C-R6-V3 - - - ---- ---- ---- 90 210 330 --96X19.6X7.8NNH4-65C-R6-V3 --96X19.6X7.8NNH4-65C-R6-V3 --96X19.6X7.8NNH4-65C-R6-V3 *OR SIMILAR NOTE: CONFIRM THAT GENERAL CONTRACTOR IS USING LATEST VERSION OF RFDS. RAD CENTER 140'-0" 140'-0" 140'-0" 140'-0" 140'-0" 140'-0" 140'-0" 140'-0" 140'-0" 140'-0" 140'-0" 140'-0" 6/14/21 FINAL CD'S NP 839612 CM IDL01003 IDL01003 1250 WEST USTICK ROAD MERIDIAN, ID 83646 161 Inverness Drive West 2nd floor Englewood, Colorado 80112 PREPARED FOR: REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: BU NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Tower Owner: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: A&E: at&t 2055 SOUTH STEARMAN DRIVE CHANDLER, AZ 85286 B RAD CENTER CHANGE04/23/21 A 4/07/21 PRELIMINARY CD'S C RAD CENTER CHANGE06/01/21 0 SUBMITTAL CD'S06/03/21 0A 6/14/21 SUBMITTAL CD'S TIM ALEX A N D E RSIGNED, EXPIRES, 28 FEB 2023 PROPOSED MONOPOLE NORTH - ELEVATION A-4.1 SITE TYPE: MONOPOLE/WICSCALE: EXISTING SOUTH ELEVATION2 SCALE: PROPOSED SOUTH ELEVATION13/16"=1'-0" (FULL SIZE) 3/32"=1'-0" (11x17)4'2'0 4' 3/16"=1'-0" (FULL SIZE) 3/32"=1'-0" (11x17)4'2'0 4' (P) AT&T WALK IN CABINET (E) 6'-0" TALL COMPOUND FENCE (P) AT&T 30KW AC DIESEL GENERATOR (E) 150'-0" MONOPOLE (E) ANTENNAS BY OTHERS (TYP.)1'-4"(P) (5) AT&T RRHS PER FOR A TOTAL OF (15) (P) (2) AT&T ANTENNAS PER SECTOR FOR A TOTAL OF (6) (P) (6) DC TRUNKS & (3) FIBER TRUNKS (P) (1) RAYCAP DC6 SURGE SUPPRESSOR PER SECTOR FOR A TOTAL OF (3) TOP OF (E) MONOPOLE “150'-0" GRADE “  AT&T ANTENNA TIP HEIGHT “144'-0" AT&T ANTENNA RAD CENTER “140'-0" (E) PAD MOUNTED TRANSFORMER ANTENNA RAD CENTER (BY OTHERS) “  ANTENNA RAD CENTER (BY OTHERS) “  ANTENNA RAD CENTER (BY OTHERS) “  (E) 6'-0" TALL COMPOUND FENCE (E) 150'-0" MONOPOLE (E) ANTENNAS BY OTHERS (TYP.) TOP OF (E) MONOPOLE “150'-0" GRADE “  (E) PAD MOUNTED TRANSFORMER ANTENNA RAD CENTER (BY OTHERS) “  ANTENNA RAD CENTER (BY OTHERS) “  ANTENNA RAD CENTER (BY OTHERS) “  (P) SITEPRO1 VFA10-HD3L4NP SECTOR FRAME (3) TOTAL 6/14/21 FINAL CD'S NP 839612 CM IDL01003 IDL01003 1250 WEST USTICK ROAD MERIDIAN, ID 83646 161 Inverness Drive West 2nd floor Englewood, Colorado 80112 PREPARED FOR: REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: BU NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Tower Owner: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: A&E: at&t 2055 SOUTH STEARMAN DRIVE CHANDLER, AZ 85286 B RAD CENTER CHANGE04/23/21 A 4/07/21 PRELIMINARY CD'S C RAD CENTER CHANGE06/01/21 0 SUBMITTAL CD'S06/03/21 0A 6/14/21 SUBMITTAL CD'S TIM ALEX A N D E RSIGNED, EXPIRES, 28 FEB 2023 PROPOSED MONOPOLE WEST ELEVATION A-4.2 SITE TYPE: MONOPOLE/WICSCALE: EXISTING EAST ELEVATION2 SCALE: PROPOSED EAST ELEVATION13/16"=1'-0" (FULL SIZE) 3/32"=1'-0" (11x17)4'2'0 4' 3/16"=1'-0" (FULL SIZE) 3/32"=1'-0" (11x17)4'2'0 4' (E) 6'-0" TALL COMPOUND FENCE (E) 150'-0" MONOPOLE (E) ANTENNAS BY OTHERS (TYP.) TOP OF (E) MONOPOLE “150'-0" GRADE “  (E) PAD MOUNTED TRANSFORMER ANTENNA RAD CENTER (BY OTHERS) “  ANTENNA RAD CENTER (BY OTHERS) “  ANTENNA RAD CENTER (BY OTHERS) “  (E) 6'-0" TALL COMPOUND FENCE (E) 150'-0" MONOPOLE (E) ANTENNAS BY OTHERS (TYP.) TOP OF (E) MONOPOLE “150'-0" GRADE “  (E) PAD MOUNTED TRANSFORMER ANTENNA RAD CENTER (BY OTHERS) “  ANTENNA RAD CENTER (BY OTHERS) “  ANTENNA RAD CENTER (BY OTHERS) “  (P) AT&T WALK IN CABINET (P) AT&T 30KW AC DIESEL GENERATOR1'-4"(P) (5) AT&T RRHS PER FOR A TOTAL OF (15) (P) (2) AT&T ANTENNAS PER SECTOR FOR A TOTAL OF (6) (P) (1) RAYCAP DC6 SURGE SUPPRESSOR PER SECTOR FOR A TOTAL OF (3) AT&T ANTENNA TIP HEIGHT “144'-0" AT&T ANTENNA RAD CENTER “140'-0" (P) SITEPRO1 VFA10-HD3L4NP SECTOR FRAME (3) TOTAL 6/14/21 FINAL CD'S NP 839612 CM IDL01003 IDL01003 1250 WEST USTICK ROAD MERIDIAN, ID 83646 161 Inverness Drive West 2nd floor Englewood, Colorado 80112 PREPARED FOR: REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: BU NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Tower Owner: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: A&E: at&t 2055 SOUTH STEARMAN DRIVE CHANDLER, AZ 85286 B RAD CENTER CHANGE04/23/21 A 4/07/21 PRELIMINARY CD'S C RAD CENTER CHANGE06/01/21 0 SUBMITTAL CD'S06/03/21 0A 6/14/21 SUBMITTAL CD'S TIM ALEX A N D E RSIGNED, EXPIRES, 28 FEB 2023 DETAILS A-5 SITE TYPE: MONOPOLE/WIC 2 RRH DETAIL3 1 SURGE SUPPRESSOR DETAIL4RRH DETAIL RRH DETAIL 7 DUAL MOUNTING BRACKET 6 CABLE BLOCK DETAIL MOUNTING BRACKET BY MANUFACTURER MOUNTING PIPE RAYCAP DC SURGE PROTECTOR, "SQUID" MANUF:RAYCAP DESC:SURGE PROTECTOR "SQUID" (OR SIMILAR) MODEL:DC9-48-60-24-8C-EV WEIGHT:26.2 LBS MOUNTING ATTACHMENTS PER STRUCTURAL 5 RRH DETAIL PART #CABLE SIZE & TYPE U of M Weight/ 10 pk A B C CXB4 Fiber Kit (4-6mm)10 PACK 1.3 lb µµµ CXB14-2 µ&DEOH PP 10 PACK 0.20 lb µµµ CXB38 µ&DEOHV LMR400 (10-12 mm)10 PACK 0.30 lb µµµ CXB12 µ&RUUXJDWHG (15.5-17.5 mm)10 PACK 0.60 lb µµµ CXB78 µ&RUUXJDWHG (27-29 mm)10 PACK 1.0 lb µµµ CXB114 µ&RUUXJDWHG (39-42 mm)10 PACK 1.6 lb µµµ CXB158 µ&RUUXJDWHG (50-54 mm)10 PACK 2.5 lb µµµ CXB214 µ&RUUXJDWHG (60-65 mm)10 PACK 3.0 lb µµµ "A" "B' "C" MANUFACTURER: NOKIA MODEL:AIRSCALE RRH 4T4R B30 100W HEIGHT:16.83" (427mm) WIDTH:12.76" (326mm) DEPTH:7.22" (173mm) WEIGHT:39.02 LBS (17.7KG) MANUFACTURER: NOKIA MODEL: AIRSCALE RRH 4T4R B12/14/29 370W AHLBBA HEIGHT:24.01" (609mm) WIDTH:14.09" (357mm) DEPTH:7.83" (198mm) WEIGHT:101.4 LBS (46KG) W/MOUNTING MANUFACTURER: NOKIA MODEL:AIRSCALE RRH 4T4R B5 160W HEIGHT:13.26" (337mm) WIDTH:11.61" (295mm) DEPTH:6.49" (165mm) WEIGHT:36.82 LBS (16.7KG) 11.61" 13.26" 6.49" 26.57" MANUFACTURER: NOKIA MODEL:AIRSCALE RRH 4T4R B25/B66 320W HEIGHT:22.04" (560mm) WIDTH:12.12" (308mm) DEPTH:5.86" (149mm) WEIGHT:66.0 LBS (30.0KG) 6.4912.87 6/14/21 FINAL CD'S NP 839612 CM IDL01003 IDL01003 1250 WEST USTICK ROAD MERIDIAN, ID 83646 161 Inverness Drive West 2nd floor Englewood, Colorado 80112 PREPARED FOR: REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: BU NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Tower Owner: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: A&E: at&t 2055 SOUTH STEARMAN DRIVE CHANDLER, AZ 85286 B RAD CENTER CHANGE04/23/21 A 4/07/21 PRELIMINARY CD'S C RAD CENTER CHANGE06/01/21 0 SUBMITTAL CD'S06/03/21 0A 6/14/21 SUBMITTAL CD'S TIM ALEX A N D E RSIGNED, EXPIRES, 28 FEB 2023 DETAILS A-5.12 GPS MOUNTING DETAIL 1 ICE BRIDGE DETAIL 5 SITEPRO1 - ER105D H-FRAME DETAIL PULL BOXES AND CONDUIT INSTALLED PER LOCAL UTILITY REQUIREMENTS 6" (TYP.) MIN.6" G 4"TRENCH MIN3'-0"2'-0"FINISHED GRADE, AC PAVING MATCH SLOPE AND THICKNESS OF EXISTING UNDISTURBED COMPACTED BACKFILL PER SITEWORK SPECIFICATIONS BACKFILL (SAND OR NATIVE SOIL) PER GEOTEC/EARTHWORK SPECIFICATION UTILITY WARNING TAPE POWER CONDUIT -SEE PLANS FOR CONDUIT SIZE FIBER CONDUIT 4" MIN TO SECONDARY ELECTRIC 12" MIN TO PRIMARY ELECTRIC 4 CONDUIT TRENCHING DETAIL 3 ANTENNA MOUNTING DETAILS SITE TYPE: MONOPOLE/WIC 318113 55-2008-06 80-6845-00 94 55-9044-00 296 80-7072-00 319 U-BOLT 114 55-5001-14 319 U-BOLT 55-6025-06 297 55-6025-06 315 UNISTRUT-80 INCH 16 80-4941-00 316 21 55-5061-00 55-8002-06 16 21 94 113 114 296 297 315 316 318 319 4 80-4941-00 100 4 4 4 55-9044-00 55-2008-06 55-5001-14 80-7072-00 55-6025-06 4 4 4 80-7070-00 32 2 80-6845-00 4 GPS MOUNT 3/8-16 X 4.5 SS HHCS PAINTED UNISTRUT HHCS ZN 3/8-16 X 1 1/4 GPS PIPE MOUNT ANCHOR SHACKLE 7/8-14 ZN NYLOCK 7/8-14 X 5.00 HHCS LIFTING EYE Washer Flat SS 3/8 Parts List ITEM PART NUMBER DESCRIPTION QTY U-BOLT 55-5061-00 55-8002-06 (P) ANTENNA (P) ANTENNA MOUNTING BRACKET (P) ANTENNA MOUNTING BRACKET PARTS LIST ITEM QTY 1 2 1 4 PART NO. X-SP126 SWA585 PART DESCRIPTION BASE SHOE PLATE PIPE COLUMN 5/8" X 5" STAINLESS WEDGE ANCHOR UNIT WT. 89.00 0.64 NET WT. 89.00 2.55 TOTAL WT. # 91.55 2 1 2 4" DETAIL A 2 3/4" 5 1/2" 2 3/4"44" 5 1/2" BASE PLATE LAYOUT A 12" BASE PLATE FOOTING3" ‘4"4'-0"DIRECT BURIAL BASE SHOE PARTS LIST ITEM QTY PART NO. P3160 PC312 UNT10 1 2 3 4 5 6 7 8 3 2 1 4 5 6 7 2 2 10 20 40 40 40 20 X-UB3312 G38FW G38LW G38NUT UNICAP PART DESCRIPTION 3-1/2" X 160" SCH 40 GALVANIZED PIPE 3-1/2" FENCE POST CAP UNISTRUT 3/8" X 3-1/2" X 4-3/4" X 2" U-BOLT (HDG.) 3/8" HDG USS FLATWASHER 3/8" HDG LOCKWASHER 3/8'' HDG HEAVY 2H HEX NUT UNISTRUT END CAP LENGTH 160 in UNIT WT. 101.25 0.59 20.38 0.73 0.01 0.01 0.03 0.03 NET WT. 202.50 1.17 203.79 14.63 0.47 0.27 1.35 0.64 TOTAL WT. # 417.77 X2 X2 X2 DETAIL A A 12 0 1 / 1 6 " 159 7/8" 24.0 609.6 10'-0" 3048 1 B 6 2 8 7 9 DETAIL A SCALE 1 : 16 16 5 4 A 15 14 12 10 13 11 DETAIL B SCALE 1 : 16 NOTES: 1. ALL METRIC DIMENSIONS ARE IN BRACKETS.13'-4" 4064ITEM PART NO. 1 MF-130 DESCRIPTION QTY. WEIGHT 2 WB-CY210 3 WBK210BHK 3.5" O.D. X 13'-4" DIRECT BURIAL PIPE COLUMN 2 101.38 LBS SAFETY GRATING 24" X 10' HARDWARE KIT (ITEMS 4-16) 1/2" X 3-5/8" X 6" GALV U-BOLT KIT 1/2" J-BOLT 1/2" GALV FLAT WASHER 1/2" GALV LOCK WASHER 1/2" GALV HEX NUT 3/8" X 1" GALV BOLT KIT 3/8" X 2" GALV BOLT KIT 3/8" GALV FLAT WASHER ô3,3(&$3 VERTICAL TRAPEZE SECTION HORIZONTAL TRAPEZE SECTION 4 WBLB243.08 24" WAVEGUIDE BRIDGE SUPPORT BRACKET 2 7.14 LBS 5 GUB-4356 6 WBJB6 7 GWF-04 8 GWL-04 9 GN-04 10 WBT243.01 11 WBT243.02 12 MT-387 SQUARE WASHER, 1-1/2" X 1-5/8" W/ 7/16" HOLE 18 0.12 LBS 13 GB-03105 14 GB-03205 15 GWF-03 16 PC-034 4 0.83 LBS 4 0.41 LBS 4 0.01 LBS 4 0.01 LBS 4 0.04 LBS 3 2.53 LBS 9 2.81 LBS 18 0.04 LBS 9 0.04 LBS 9 0.01 LBS 2 0.28 LBS 1 111.00 LBS 1 6/14/21 FINAL CD'S NP 839612 CM IDL01003 IDL01003 1250 WEST USTICK ROAD MERIDIAN, ID 83646 161 Inverness Drive West 2nd floor Englewood, Colorado 80112 PREPARED FOR: REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: BU NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Tower Owner: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: A&E: at&t 2055 SOUTH STEARMAN DRIVE CHANDLER, AZ 85286 B RAD CENTER CHANGE04/23/21 A 4/07/21 PRELIMINARY CD'S C RAD CENTER CHANGE06/01/21 0 SUBMITTAL CD'S06/03/21 0A 6/14/21 SUBMITTAL CD'S TIM ALEX A N D E RSIGNED, EXPIRES, 28 FEB 2023 STRUCTURAL PLAN & DETAILS S-1 SITE TYPE: MONOPOLE/WIC 1 PROFILE VIEW OF CONCRETE STOOP 2 4 FOUNDATION DETAILS 3 FOUNDATION SECTION DETAIL TYPE I CONCRETE SLAB W/ 2" MIN. COVER WWF6X6XW2.9XW2.9 GRADE COMPACTED SUBGRADE PER SOILS REPORT, TYP. 1/2" EXPANSION JOINT 6" MAX.8"1.ALL DIMENSIONS OF SHELTER SHALL MATCH MANUFACTURER PROVIDED SPECIFICATIONS 2.ALL REQUIRED TIE DOWN PLATES, SHIMS, BOLTS, AND ANCHORS SHALL BE PLACED INSIDE SHELTER PRIOR TO SHIPMENT FROM MANUFACTURER 3.SLOPE GRADE AWAY FROM FOUNDATION. 4.SLAB DIMENSIONS, ORIENTATION, AND LOCATION OF STOOP TO MATCH CABINET MODEL AND DETAILS 5.GENERATOR CONCRETE PAD SHALL MATCH DETAILS AND DIMENSIONS OF THE PROVIDED GENERAC MODEL NOTES: 4'-0" PER MANUFACTURER SPECS 9'-0"PER MANUFACTURER SPECS8'-0" PER MANUFACTURER SPECS 8'-0"PER MANUFACTURER SPECSGENERATOR WIC NOT USED 2" MINIMUM 3" CLEAR TO END OF BARS 7" 2500 PSI CONCRETE SLAB (BROOM FINISHED) EXISTING GRADE TOOLED EDGE PERIMETER 4" COMPACTED, CRUSHED ROCK FILL ON UNDISTURBED SOIL #4 @ 6" O.C. TOP W/ OPTIONAL 2'-6" LAP O.C. NOTE: 1.VERIFY GENERATOR AND OR PROPANE TANK SPECS PRIOR TO CONSTRUCTION. 2.FROST DEPTH NOT CONSIDERED PER IBC 2013 SECTION 1809.5 EXCEPTION 2 (FREE STANDING BUILDINGS WITH 400 SQUARE FEET OR LESS FOR OTHER THAN LIGHT-FRAMED CONSTRUCTION) 3.INSTALL (4) HILTI HSL-3M12 ANCHOR BOLTS WITH AN EFFECTIVE EMBEDMENT DEPTH OF 3.15" (SURFACE FLATNESS MAX 1 4" IN 10'-0") 4.FIELD VERIFY EXISTING CONDITIONS. #4 @ 12" O.C. (3) #4 BARS CONT. W/ 3'-0" MIN LAPS @ 6" O.C. TYP ALL ENDS 3" CLEAR TO TOP AND BOTTOM OF BARS 3" CLEAR TO TOP AND BOTTOM OF BARS 6/14/21 FINAL CD'S NP 839612 CM IDL01003 IDL01003 1250 WEST USTICK ROAD MERIDIAN, ID 83646 161 Inverness Drive West 2nd floor Englewood, Colorado 80112 PREPARED FOR: REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: BU NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Tower Owner: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: A&E: at&t 2055 SOUTH STEARMAN DRIVE CHANDLER, AZ 85286 B RAD CENTER CHANGE04/23/21 A 4/07/21 PRELIMINARY CD'S C RAD CENTER CHANGE06/01/21 0 SUBMITTAL CD'S06/03/21 0A 6/14/21 SUBMITTAL CD'S TIM ALEX A N D E RSIGNED, EXPIRES, 28 FEB 2023 WIC DETAILS S-2 SITE TYPE: MONOPOLE/WIC1 WIC DETAILS 61 61 80-4879-00 132 58-0142-11 280 58-0058-02 313 ALARM BLOCK-ATT 71 58-0121-06 299 58-0121-02 80-4879-00 314 80-7075-00 269 2349062-LOUVER 321 SMOKE DETECTER 229 72-0631-00 339 58-0309-04 326 55-9304-03 328 58-0271-02 329 55-9383-01 236 58-9058-00 278 HVAC CONTROL BOX 267 80-7217-00 267 80-7217-00 267 80-7217-00 267 80-7217-00 RIGHT HAND WALL DETAIL 322 582127000zz041- NETSURE 158 80-6595-00 E 159 307 80-7073-00 299 310 23-0181-00 58-0121-02 71 58-0121-06 271 58-0309-05 315 80-7070-00 327 58-9008-03 276 2"X60 CONDUIT 233 CONTROLLER DOOR ALARM FRONT WALL DETAIL 71 265 545047-AM 58-0121-06 208 58-0218-00 327 58-9008-03 271 58-0309-05 SECTION E-E E 247 58-0142-17 BACK WALL DETAIL 314 314 80-7075-00 80-7075-00 269 2349062-LOUVER 265 545047-AM 328 58-0271-02 329 265 545047-AM 55-9383-01 326 55-9304-03 246 80680 245 80685 299 71 58-0121-02 58-0121-06 SECTION F-F Parts List ITEM QTY 1 7 8 9 1 1 1 1 10 11 12 13 16 17 18 19 20 21 22 24 25 28 32 39 45 46 47 48 52 59 61 71 76 79 86 87 88 89 94 98 99 105 113 114 120 126 132 158 159 179 203 204 208 209 211 212 213 214 217 218 219 220 221 222 223 224 225 226 228 229 233 236 237 238 240 241 242 243 244 245 246 247 253 254 265 267 268 269 271 276 277 278 280 281 282 288 289 290 293 296 297 298 299 302 306 307 310 313 314 315 316 318 319 320 321 322 326 327 328 329 335 337 338 339 340 341 343 344 345 346 347 348 349 350 351 352 353 354 355 356 PART NUMBER 50-2024-00 80-4919-00 80-7228-00 80-7223-00 13 55-6010-02 181 55-2002-03 1 1 4 72-0624-00 72-0625-00 80-4941-00 168 55-6010-03 9 55-2019-00 12 55-6006-06 1 55-6006-10 100 55-8002-06 45 55-2000-03 1 1 1 72-0634-00 72-0633-00 72-0626-00 1 TILE FLOOR-ATT 55-8001-00 80-7232-00 80-7235-00 55-2033-00 50-1809-00 30-0013-02 58-0049-05 80-4879-00 58-0121-06 80-7236-00 4 2 1 6 1 1 8 5 5 1 4 7 8 556731-LIGHT TRIM-1 80-4914-00 12 TRIM-3 4 4 1 1 8 4 4 1 4 1 1 TRIM-4 55-9044-00 80-7240-00 80-4896-NP 55-6009-01 55-2008-06 55-5001-14 72-0304-01 55-8001-09 58-0142-11 80-6595-00 1 DOOR ALARM 1 1 1 1 1 1 1 4 1 1 2 TRIM-16.725 80-7233-00 80-7234-00 58-0218-00 80-7222-00 80-7225-00 80-7224-00 80-7226-00 80-7227-00 80-7230-00 80-6941-00 32 12-24_CAGE_NUT 20 55-5104-00 2 4 1 1 1 2 4 1 58-0191-14 55-6006-03 72-0627-00 72-0628-00 72-0629-00 72-0630-00 55-2036-00 72-0631-00 1 CONTROLLER 1 58-9058-00 1 ECUA12ACA-AC 1 4 2 2 50-2017-00 80-7237-00 80-7238-00 80-7239-00 26 53-0012-00 1 1 1 2 1 2 50-2019-00 80685 80680 58-0142-17 58-0122-04 58-0224-07 2 545047-AM 80-7217-00 72-0632-00 5 2 1 2349062-LOUVER 2 58-0309-05 2 2"X60 CONDUIT 1 EXT WALL LOUVER 1 HVAC CONTROL BOX 2 58-0058-02 12 25-0005-00 1 GROUND LOOP 4 58-0057-02 1 1X3 CARFLEX 1 1X26 CARFLEX 2 INT-EXT GRD CABLE 80-7072-00 55-6025-06 55-2002-07 58-0121-02 58-0264-04 72-0635-00 80-7073-00 23-0181-00 4 4 4 3 2 1 2 2 1 ALARM BLOCK-ATT 3 4 80-7075-00 80-7070-00 32 55-5061-00 2 80-6845-00 4 U-BOLT 4 58-0049-32 1 SMOKE DETECTER 1 582127000zz041- NETSURE 1 4 2 2 9 9 9 1 7 5 2 1 55-9304-03 58-9008-03 58-0271-02 55-9383-01 55-6006-34 55-8001-12 80-6847-00 58-0309-04 58-0191-09 58-0264-03 80-7038-00 80-7039-00 1 LOAD CENTER 2 1 2 80-7035-00 80-7036-00 58-0027-00 16 55-2033-01 16 90-0017-00 16 55-9212-00 24 58-0049-44 16 58-0049-45 58-0049-46 58-0049-47 58-0049-48 4 2 1 2" x 7" PIPE NIPPLE 2" EMT BOX CONNECTOR 2" LOCK RING 2" PLASTIC PIPE BUSHING 1/2-13 X 2.5 SS HHCS .50 SS LOCK WASHER 1/2" ID X 2" OD SS WASHER SCE-24EL2408LP COMP LUG #2, 2 HOLE,STRNDED, 2 HOLE SHRT ROXTEC EZENTRY 16/16 SIDE AC SEAL TOP AC SEAL LIGHT MNT PLATE WALL SLEEVE RECEPTACLE BOX GFCI W/MOUNTING EARS 1/4-20 NUTSERT - CLOSED END 1/4-20 x 1.00 SS SECURITY BOLT 1/4" SEALING WASHER 2" CABLE RACK END CAPS WALL BRKT F/2" CABLE RACK LADDER RACK 2" X 57/58" SOLID LADDER RACK 2" X 47/48" SOLID LADDER RACK 2" X 25" SOLID GPS MOUNT 3/8-16 X 4.5 SS HHCS Nut Hex SS 3/8-16 COVER F/4" SQ BOX ROXTEC EZENTRY 4/4 MELAMINE PANEL COVER PLATE FLEXIBLE PLASTIC PLUG 1-1/2" RACK BRACE PAINTED UNISTRUT HHCS ZN 3/8-16 X 1 1/4 GPS PIPE MOUNT AUX CABLE RACK BRKT ANCHOR SHACKLE 36" THRESHOLD AWNING - SHELTER SCREW TEK SS #12 X 3/4 7/8-14 ZN NYLOCK 7/8-14 X 5.00 HHCS MELAMINE PANEL Washer Split Ring SS 3/8 .25 X 2 X 14 GRD BAR DOOR ALARM BRKT SHELTER CELING PANEL SHELTER CELING PANEL LIGHT SWITCH COVER 4" SQ SHELTER,WALL CORNER WALL CORNER SHELTER WALL PANEL CORNER SUPPORT WALL CORNER TOP DOOR SEAL CHNL SIDE DOOR SEAL CHNL 12-24 CAGE NUT SCREW FHPH SS 12-24 X 1" COMP LUG 10AWG, 2 HOLE, 10 STUD, 5/8 CTR Screw HHCS SS 1/4-20 x 3/4 MELAMINE HDR PANEL MELAMINE PANEL MELAMINE PANEL MELAMINE PANEL AHS4-616-150BS NUTSERT TELCO BOARD-WHITE FOLD DOWN DESK SLIMPAC 1 36" DOOR FRAME A/C WALL SUPPORT A/C WALL SUPPORT A/C WALL SUPPORT RIVET POP SS/SS .187 X .126-.250 CE 36" DOOR ASSEMBLY SUPPLY GRILL RETURN GRILL ROSENBERGER GRB-ATTG0424PUNI 1/2" RAISED GFCI COVER 4" SQ 20A RECEPT ROXTEC MNT PLATE MELAMINE PANEL FRAME: TOP & BOTTOM 12X12X4 PULL BOX 2" EMT EXT. LED MOTION LIGHT HALO STANDOFF CLAMPS - 1" 1" inch 90 degree liquidtight non-metallic fitting 80x80 BASE SHELTER WALL PANEL SHELTER WALL PANEL SHELTER WALL PANEL CARRIAGE BOLT SS 5/16-18 X 1 NUT HEX FLANGED SS 5/16 LH SUB FLOOR RH SUB FLOOR LIFTING EYE CARRIAGE BOLT SS 5/16-18 X 3/4 5/16-18 NUTSERT - SEALING 3/8-16 x 1.25 SS HHCS 3/8-16 x 1.00 SS HHCS Washer Flat SS 3/8 NYLOCK NUT SS 3/8-16 MELAMINE PANEL MELAMINE PANEL MELAMINE PANEL TILE FLOOR Washer Split Ring SS 1/4 CELING PANEL SHELTER CELING PANEL NUTSERT AHS4-420-165 80x80 ROOF ASSY LADDER RACK HORIZONTAL TEE LADDER RACK BRKT 4S BOX, DBL GANG, 2-1/8" DEEP W/DIMPLE SHELTER CELING PANEL 4 LED LIGHT ASSY SHELTER CORNER TRIM DESCRIPTION 6/14/21 FINAL CD'S NP 839612 CM IDL01003 IDL01003 1250 WEST USTICK ROAD MERIDIAN, ID 83646 161 Inverness Drive West 2nd floor Englewood, Colorado 80112 PREPARED FOR: REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: BU NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Tower Owner: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: A&E: at&t 2055 SOUTH STEARMAN DRIVE CHANDLER, AZ 85286 B RAD CENTER CHANGE04/23/21 A 4/07/21 PRELIMINARY CD'S C RAD CENTER CHANGE06/01/21 0 SUBMITTAL CD'S06/03/21 0A 6/14/21 SUBMITTAL CD'S TIM ALEX A N D E RSIGNED, EXPIRES, 28 FEB 2023 GENERATOR DETAILS S-3 SITE TYPE: MONOPOLE/WIC1 GENERATOR DETAILS 6/14/21 FINAL CD'S NP 839612 CM IDL01003 IDL01003 1250 WEST USTICK ROAD MERIDIAN, ID 83646 161 Inverness Drive West 2nd floor Englewood, Colorado 80112 PREPARED FOR: REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: BU NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Tower Owner: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: A&E: at&t 2055 SOUTH STEARMAN DRIVE CHANDLER, AZ 85286 B RAD CENTER CHANGE04/23/21 A 4/07/21 PRELIMINARY CD'S C RAD CENTER CHANGE06/01/21 0 SUBMITTAL CD'S06/03/21 0A 6/14/21 SUBMITTAL CD'S TIM ALEX A N D E RSIGNED, EXPIRES, 28 FEB 2023 GENERAL ELECTRICAL/ GROUNDING NOTES E-1 15.THE ENTIRE ELECTRICAL INSTALLATION SHALL BE GROUNDED AS REQUIRED BY ALL APPLICABLE CODES. 16.PATCH, REPAIR, AND PAINT ANY AREA THAT HAS BEEN DAMAGED IN THE COURSE OF THE ELECTRICAL WORK. 17.IN DRILLING HOLES INTO CONCRETE (WHETHER FOR FASTENING OR ANCHORING PURPOSES OR PENETRATIONS THROUGH THE FLOOR FOR CONDUIT RUNS, PIPE RUNS, ETC.) IT MUST BE CLEARLY UNDERSTOOD THAT TENDONS AND RE-BARS WILL NOT BE DRILLED INTO, CUT, OR DAMAGED UNDER ANY CIRCUMSTANCES. 18.LOCATION OF TENDONS AN RE-BARS ARE NOT DEFINITELY KNOWN AND THEREFORE MUST BE SEARCHED FOR BY APPROPRIATE METHODS AND EQUIPMENT VIA X-RAY, OR OTHER DEVICES THAT CAN ACCURATELY LOCATE THE REINFORCING STEEL TENDONS. 19.PENETRATIONS IN FIRE RATED WALLS SHALL BE FIRE STOPPED IN ACCORDANCE WITH APPLICABLE LOCAL BUILDING CODES. USING U.L. RATED MATERIALS. 20.ELECTRICAL CONTRACTOR IS TO COORDINATE WITH UTILITY COMPANY FOR CONNECTION OF TEMPORARY AND PERMANENT POWER TO THE SITE. THE TEMPORARY POWER AND ALL HOOK-UP COSTS SHALL BE PAID BY THE CONTRACTOR. 21.ELECTRICAL CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AND/OR CATALOG CUT-SHEETS ON ALL NON-SPECIFIED ORIGINAL MATERIALS AND EQUIPMENT, TO PROJECT MANAGER PRIOR TO COMMENCEMENT OF THE WORK. 22.UPON COMPLETION OF WORK, CONDUCT CONTINUITY AND SHORT CIRCUIT, AS WELL AS, GROUNDING TEST, GROUNDING TEST SHALL BE PREFORMED BY INDEPENDENT TESTING AGENCY, WITH WRITTEN REPORT SUBMITTED TO THE PROJECT MANAGER FOR REVIEW AND APPROVAL. 23.CLEAN PREMISES DAILY OF ALL DEBRIS RESULTING FROM WORK AND LEAVE WORK PREMISES IN A COMPLETE AND UNDAMAGED CONDITION. 24.ALL EXTERIOR WALL PENETRATIONS SHALL BE SEALED WITH POLYSEAM SEALANT. 25.ALL #2 TINNED BARE COPPER DOWNLEADS TO BE PROTECTED BY 1/2" P.V.C. PIPE AND SECURED. 26.COMPRESSION FITTINGS TO BE USED ON ALL CONDUITS (NO SET SCREWS). 27.ALL #6 STRANDED COPPER WITH GREEN INSULATION TO BE ATTACHED WITH CRIMPED DOUBLE LUG, ATTACHED WITH NUTS, BOLTS AND STAR WASHERS TYPICAL AND NO-OX GREASE BETWEEN LUG AND BUS BAR. 28.ALL ABOVE GROUND CONDUIT SHALL BE RIGID GALVANIZED CONDUIT WITH WEATHERPROOF FITTINGS. *DATE OF JOB COMPLETION SHALL BE THE DATE ON THE CONTRACTOR'S "NOTICE OF COMPLETION" SUBMITTED TO THE OWNER. ELECTRICAL NOTES AAV ALTERNATE ACCESS VENDOR AC ALTERNATING CURRENT AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AIC AMPERES INTERRUPT CURRENT AL ALUMINUM A/G ABOVE GROUND AGB ANTENNA GROUND BAR ATS AUTOMATIC TRANSFER SWITCH AWG AMERICAN WIRE GAUGE AWS ADVANCED WIRELESS SERVICES BATT BATTERY BBU BASEBAND UNIT BCW BARE COPPER WIRE BSCW BARE STRANDED COPPER WIRE BTCW BARE TINNED COPPER WIRE C CONDUIT CAB CABINET CGB COLLECTOR GROUND BAR CKT CIRCUIT CT CURRENT TRANSFORMER CU COPPER DC DIRECT CURRENT DEI DIGITAL EXPANSION INTERFACE DISC DISCONNECT EGB EXTERIOR GROUND BAR EMT ELECTRICAL METALLIC TUBING FMT FLEXIBLE METALLIC TUBING G GROUND GEN GENERATOR GFCI GROUND FAULT CURRENT INTERRUPTER GIP GENERATOR INTERFACE PANEL GND GROUND GPS GLOBAL POSITIONING SYSTEM GR GROWTH (CABINET) GRC GALVANIZED RIGID (STEEL) CONDUIT HVAC HEATING, VENTILATING, AND AIR CONDITIONING IPC IDAHO POWER COMPANY IGB INTERIOR GROUND BAR IGR INTERIOR GROUND RING (HALO) IMC INTERMEDIATE METALLIC CONDUIT ISCW INSULATED STRANDED COPPER WIRE KAIC KILOAMPERES INTERRUPT CURRENT LTE LONG TERM EVOLUTION MGB MAIN (OR MASTER) GROUND BAR MIN MINIMUM MTS MANUAL TRANSFER SWITCH MW MICROWAVE N NEUTRAL NEC NATIONAL ELECTRIC CODE NID NETWORK INTERFACE DEVICE OC ON CENTER O/H OVERHEAD PCS PERSONAL COMMUNICATION SERVICES PPC POWER PROTECTION CABINET PRC PRIMARY RADIO CABINET PT POTENTIAL TRANSFORMER PVC POLYVINYL CHLORIDE PWR POWER RAC RIGID ALUMINUM CONDUIT RECT RECTIFIER RET REMOTE ELECTRICAL TILT RGS RIGID GALVANIZED STEEL RMT RIGID METALLIC TUBING RRH REMOTE RADIO HEAD RRU REMOTE RADIO UNIT RU RACK UNIT SCA SHORT CIRCUIT AMPERES SCCR SHORT CIRCUIT CURRENT RATING SPD SURGE PROTECTIVE DEVICE S/S STAINLESS STEEL TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR TYP TYPICAL U/G UNDERGROUND UTP UNSHIELDED TWISTED PAIR VZW VERIZON WIRELESS WP WEATHERPROOF WW WIREWAY XFMR TRANSFORMER AGP PANEL A MOTOR S S S3 D DCP AGT UGT HFLEX GAS UGP UGW SD T METER @:# FE P UGF H2 J X X X X X X X X X X X X X X X X XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX X X X X X X X X X X XXXXXX X X X X X X X X X XXXXXXXXXXXXXXXXX X X X X X X X X 6/14/21 FINAL CD'S NP 839612 CM IDL01003 IDL01003 1250 WEST USTICK ROAD MERIDIAN, ID 83646 161 Inverness Drive West 2nd floor Englewood, Colorado 80112 PREPARED FOR: REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: BU NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Tower Owner: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: A&E: at&t 2055 SOUTH STEARMAN DRIVE CHANDLER, AZ 85286 B RAD CENTER CHANGE04/23/21 A 4/07/21 PRELIMINARY CD'S C RAD CENTER CHANGE06/01/21 0 SUBMITTAL CD'S06/03/21 0A 6/14/21 SUBMITTAL CD'S TIM ALEX A N D E RSIGNED, EXPIRES, 28 FEB 2023 UTILITY SITE PLAN E-2 SITE TYPE: MONOPOLE/WIC SCALE: PROPOSED UTILITY SITE PLAN13/8"=1'-0" (FULL SIZE) 3/16"=1'-0" (11x17)2'2'01' (P) UNDERGROUND POWER ROUTE FROM POWER SOURCE TO METER (2" CONDUIT) (POWER SOURCE LOCATION TO BE DETERMINED BY OTHERS) (PENDING UCR) (P) UNDERGROUND POWER FROM DISCONNECT TO LOAD CENTER (2" CONDUIT) (PENDING UCR) (P) UNDERGROUND FIBER FROM FIBER SOURCE TO TELCO DEMARCATION POINT (FIBER SOURCE LOCATION TO BE DETERMINED BY OTHERS) (PENDING UCR) (P) UNDERGROUND CONDUITS FROM GENERATOR TO WIC (ONE 2" & TWO 1" CONDUIT) (PENDING UCR) (P) AT&T 30KW AC DIESEL GENERATOR ON 4'-0"X9'-0" CONCRETE PAD (E) 150'-0" MONOPOLE (E) FENCE (E) FENCE GATE (E) UTILITY FRAME BY OTHERS (E) LEASE AREA BY OTHERS (E) ICE BRIDGE BY OTHERS (E) EQUIPMENT SHELTER BY OTHERS (E) ICE BRIDGE BY OTHERS 19'-0" (E) UTILITY VAULT (E) PAD MOUNTED TRANSFORMER 20'-0"20'-0"29'-0"29'-0"15'-0"20'-0"UGPUGPUGPUGPUGPUGPUGPUGPUGPUGP (P) AT&T 8'-0"x8'-0" WALK-IN CABINET (SEE SHEET A-2.2 FOR DETAILS) (P) AT&T UTILITY FRAME W/ ELECTRICAL EQUIPMENT (P) AT&T 19'-0" ICE BRIDGE (P) AT&T 15'-0"X20'-0" LEASE AREA (E) 20'X20' CONCRETE PAD UGFUGFUGFUGPUGPUGPUGPUGPUGPUGPUGPUGP POWER ONE-LINE DIAGRAM E-32ONE-LINE DIAGRAM SITE TYPE: MONOPOLE/WIC 6/14/21 FINAL CD'S NP 839612 CM IDL01003 IDL01003 1250 WEST USTICK ROAD MERIDIAN, ID 83646 161 Inverness Drive West 2nd floor Englewood, Colorado 80112 PREPARED FOR: REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: BU NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Tower Owner: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: A&E: at&t 2055 SOUTH STEARMAN DRIVE CHANDLER, AZ 85286 B RAD CENTER CHANGE04/23/21 A 4/07/21 PRELIMINARY CD'S C RAD CENTER CHANGE06/01/21 0 SUBMITTAL CD'S06/03/21 0A 6/14/21 SUBMITTAL CD'S TIM ALEX A N D E RSIGNED, EXPIRES, 28 FEB 2023 (N) IPC PAD MOUNTED XFMR, 25KVA, 120/240V, ݊: 1 3$1(/$9݊ 3W, NEMA 1, INTERSECT CAT. NO. AA-G-1220042-3S OR APPROVED EQUAL PANEL 'ATT' PT. #1 PT. #4 (N) SHELTER (N) 3#3/0 THWN + 1#6G IN 2" PVC (N) CAMLOCK GIP, $9݊ 3W, ROAM CAT. NO. MTC6001EC-2 CONTROL PANEL 2P150 HTR/BATT. CHARGER (N) GENERATOR, 15KVA/30KW, 9݊: DIESEL 2.4L, GENERAC SD030 OR APPROVED EQUAL (N) 1" PVC FOR CONTROLS & ALARMS (TYP) (N) 3#12 THWN + 1#12G IN 3 4" PVC (TYP) (N) 3#1/0 THWN + 1#6G IN 2" PVC (N) 3#3/0 THWN + 1#6G IN 2" EMT (N) 3#350 MCM THW IN 2" PVC SCH. 80 SHORT CIRCUIT CALCULATIONS BASED UPON POINT METHOD AS ILLUSTRATED IN BUSSMAN PUBLICATION SPD-90. FAULT VALUES SHOWN ARE FOR LINE-TO-LINE FAULT @ 208 VAC FAULT CURRENT AT TRANSFORMER SECONDARY PER LOCAL POWER COMPANY ISC1 =VP-UT/VS-UT x MUT x ISCP-UT =12175 A f1 = 2 x L x I SC1(L-L) =2 x 10 x 12175 =0.0515 C1 x n x VL-L 22737 x 1 x 208 M1 = 1 = 1 =0.9510 1 + f 1 1 + 0.0515 FAULT CURRENT AT METER BANK ISC2 =M1 x ISC1 =0.951 x 12175 =11579 A f 2 = 2 x L x I SC2(L-L) =2 x 3 x 11579 =0.0092 C2 x n x VL-L 36500 x 208 M2 = 1 = 1 =0.9909 1 + f 2 1 + 0.0092 FAULT CURRENT AT METER BANK BUSBAR ISC3 =M2 x ISC2 =0.9909 x 11579 =11474 A f 3 = 2 x L x I SC3(L-L) =2 x 50 x 11474 =0.3962 C3 x n x VL-L 13923 x 1 x 208 M3 = 1 = 1 =0.7162 1 + f 3 1 + 0.3962 FAULT CURRENT AT PANEL 'ATT' ISC4 =M3 x ISC3 =0.7162 x 11474 =8218 A (N) METER , 200A, 9݊: W/ (1) METER SOCKET, NEMA 3R PT. #2 PT. #3 NEW EMERSON 7100 DC POWER PLANT REATED @10 KAIC 1 FAULT CALCULATIONS 3 PANEL SCHEDULE 6/14/21 FINAL CD'S NP 839612 CM IDL01003 IDL01003 1250 WEST USTICK ROAD MERIDIAN, ID 83646 161 Inverness Drive West 2nd floor Englewood, Colorado 80112 PREPARED FOR: REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: BU NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Tower Owner: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: A&E: at&t 2055 SOUTH STEARMAN DRIVE CHANDLER, AZ 85286 B RAD CENTER CHANGE04/23/21 A 4/07/21 PRELIMINARY CD'S C RAD CENTER CHANGE06/01/21 0 SUBMITTAL CD'S06/03/21 0A 6/14/21 SUBMITTAL CD'S TIM ALEX A N D E RSIGNED, EXPIRES, 28 FEB 2023 BATTERY DETAILS & SPECIFICATIONS E-43 NOTES 2 MARATHON M12V180FT DETAILS 5 BATTERY ROOM SIGN DETAIL 4 MARATHON M12V180FT CODE REQUIREMENTS 1 MARATHON M12V180FT DETAILS 6/14/21 FINAL CD'S NP 839612 CM IDL01003 IDL01003 1250 WEST USTICK ROAD MERIDIAN, ID 83646 161 Inverness Drive West 2nd floor Englewood, Colorado 80112 PREPARED FOR: REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: BU NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Tower Owner: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: A&E: at&t 2055 SOUTH STEARMAN DRIVE CHANDLER, AZ 85286 B RAD CENTER CHANGE04/23/21 A 4/07/21 PRELIMINARY CD'S C RAD CENTER CHANGE06/01/21 0 SUBMITTAL CD'S06/03/21 0A 6/14/21 SUBMITTAL CD'S TIM ALEX A N D E RSIGNED, EXPIRES, 28 FEB 2023 ELECTRICAL DC & FIBER CABLE DIAGRAM E-5 NEW LTE RRH TYP1/2" JUMPER TO ANTENNA TYP. 5 3 2 1 3 3 4 4 5 5 6 6 FIBER TRAYS (ALPHA) (BETA) (GAMMA) INDOOR UNIT RECTIFIER 4 6 SIAD DC PANEL OD-DC-12 2 RECTIFIER RECTIFIERRECTIFIER 46 46 46 NEW LTE RRH TYP 1/2" JUMPER TO ANTENNA TYP. 4 466 4 6 46 46 46 1/2" JUMPER TO ANTENNA TYP. 4 466 4 6 46 46 46 NEW LTE RRH TYP NEW LTE RRH TYP NEW LTE RRH TYP FUTURE LTE RRH TYP NEW LTE RRH TYP NEW LTE RRH TYP NEW LTE RRH TYP NEW LTE RRH TYP FUTURE LTE RRH TYP NEW LTE RRH TYP NEW LTE RRH TYP NEW LTE RRH TYP NEW LTE RRH TYP FUTURE LTE RRH TYP NEW LTE RRH TYP NEW LTE RRH TYP 1.REFER TO FINAL RFDS FOR RF DESIGN AND PLUMBING. 2.REFER TO FINAL RFDS FOR FINAL RADIO HEAD COUNT. 3.REFER TO EQUIPMENT LAYOUT FOR RACK LOCATION. 4.WIRE LENGTH NOT TO EXCEED 15' FROM SURGE SUPPRESSOR TO RRH. 5.RRH & SQUID DESIGN TYPICAL PER SECTOR. 6.ROUTE TO THE NEAREST GROUND BAR TYP. 7.DAISY CHAIN RRHs ONLY WHEN REQUIRED BY SPECTRUM CONSTRAINTS. NOTES: RAYCAP SURGE SUPPRESSOR DC9-48-60-24-8C-EV CIRCUIT SCHEDULE 1 2 -48VDC 50A CIRCUIT (8-AWG) 18 PAIR FIBER OPTIC TRUNK CABLE 3 4 5 3 PAIR #8-AWG DC TRUNK CABLE #8-AWG DC JUMPER FIBER OPTIC JUMPER CABLE 6 -48VDC 50A CIRCUIT (8-AWG) CABLE LENGTH TABLE SECTOR PDF DISTANCE & CABLE TYPE DC-6 DISTANCE & CABLE TYPE SQUID DISTANCE & CABLE TYPE RRH TOTAL CABLE LENGTH FINAL VOLTAGE ALPHA 6'#8 AWG 126'(2) #8 AWG 6'#8 AWG 138'SEE CALCULATIONS BETA 6'#8 AWG 126'(2) #8 AWG 6'#8 AWG 138'SEE CALCULATIONS GAMMA 6'#8 AWG 126'(2) #8 AWG 6'#8 AWG 138'SEE CALCULATIONS RAYCAP SURGE SUPPRESSOR DC9-48-60-24-8C-EV RAYCAP SURGE SUPPRESSOR DC9-48-60-24-8C-EV X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X XXXXXXXXXXXXXXXXXXXXXXXXGROUNDING PLAN, NOTES & DETAILS G-1 SITE TYPE: MONOPOLE/WIC 6/14/21 FINAL CD'S NP 839612 CM IDL01003 IDL01003 1250 WEST USTICK ROAD MERIDIAN, ID 83646 161 Inverness Drive West 2nd floor Englewood, Colorado 80112 PREPARED FOR: REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: BU NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Tower Owner: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: A&E: at&t 2055 SOUTH STEARMAN DRIVE CHANDLER, AZ 85286 B RAD CENTER CHANGE04/23/21 A 4/07/21 PRELIMINARY CD'S C RAD CENTER CHANGE06/01/21 0 SUBMITTAL CD'S06/03/21 0A 6/14/21 SUBMITTAL CD'S TIM ALEX A N D E RSIGNED, EXPIRES, 28 FEB 2023 SCALE: EQUIPMENT GROUNDING PLAN13/4"=1'-0" (FULL SIZE) 3/8"=1'-0" (11x17)1'06"1' GENERAL GROUNDING NOTES: 1.GROUNDING SHALL BE INSTALLED 6" BELOW FROST DEPTH OR 30" BELOW GRADE, WHICHEVER IS GREATER. CONFIRM FROST DEPTH WITH JURISDICTION. 2.ALL DETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL INSTALLATION AND CONSTRUCTION MAY VARY DUE TO SITE SPECIFIC CONDITIONS. 3.GROUND ALL ANTENNA BASES, FRAMES, CABLE RUNS, AND OTHER METALLIC COMPONENTS USING GROUND WIRES AND CONNECT TO SURFACE MOUNTED BUS BARS. FOLLOW ANTENNA AND BTS MANUFACTURERS PRACTICES FOR GROUNDING REQUIREMENTS. GROUND COAX SHIELD AT BOTH ENDS AND EXIT FROM TOWER OR POLE USING MFR'S PRACTICES. 4.ALL GROUND CONNECTIONS SHALL BE CADWELD. ALL WIRES SHALL BE COPPER THHN/THWN. ALL GROUND WIRE SHALL BE GREEN INSULATED WIRE ABOVE GROUND. 5.CONTRACTOR TO VERIFY AND TEST GROUND TO SOURCE. GROUNDING AND OTHER OPERATIONAL TESTING WILL BE WITNESSED BY AT&T REPRESENTATIVE. 6.ELECTRICAL CONTRACTOR TO PROVIDE DETAILED DESIGN OF GROUNDING SYSTEM, AND RECEIVE APPROVAL OF DESIGN BY AUTHORIZED AT&T MOBILITY REPRESENTATIVE, PRIOR TO INSTALLATION OF GROUNDING SYSTEM. PHOTO DOCUMENT ALL CADWELDS AND GROUND RING 7.NOTIFY CONSTRUCTION MANAGER IF THERE ARE ANY DIFFICULTIES INSTALLING GROUNDING SYSTEM DUE TO SITE SOIL CONDITIONS. SCALE: ANTENNA GROUNDING PLAN1 1/2"=1'-0" (FULL SIZE) 1/4"=1'-0" (11x17)2'2'1'0 6/14/21 FINAL CD'S NP 839612 CM IDL01003 IDL01003 1250 WEST USTICK ROAD MERIDIAN, ID 83646 161 Inverness Drive West 2nd floor Englewood, Colorado 80112 PREPARED FOR: REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: BU NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Tower Owner: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: A&E: at&t 2055 SOUTH STEARMAN DRIVE CHANDLER, AZ 85286 B RAD CENTER CHANGE04/23/21 A 4/07/21 PRELIMINARY CD'S C RAD CENTER CHANGE06/01/21 0 SUBMITTAL CD'S06/03/21 0A 6/14/21 SUBMITTAL CD'S TIM ALEX A N D E RSIGNED, EXPIRES, 28 FEB 2023 GROUNDING DETAILS G-2 A EXTERIOR GROUND RING: #2 AWG SOLID COPPER, BURIED AT A DEPTH OF AT LEAST 30 INCHES BELOW GRADE, OR 6 INCHES BELOW THE FROST LINE AND APPROXIMATELY 24 INCHES FROM THE EXTERIOR WALL OR FOOTING. (ATT-TP-76416 2.2.3.5/7.5.1) TOWER GROUND RING: THE GROUND RING SYSTEM SHALL BE INSTALLED AROUND AN ANTENNA TOWER'S LEGS, AND/OR GUY ANCHORS. WHERE SEPARATE SYSTEMS HAVE BEEN PROVIDED FOR THE TOWER AND THE BUILDING, AT LEAST TWO BONDS SHALL BE MADE BETWEEN THE TOWER RING GROUND SYSTEM AND THE BUILDING RING GROUND SYSTEM USING MINIMUM #2 AWG SOLID COPPER CONDUCTORS. (ATT-TP-76416 7.5.1) INTERIOR GROUND RING: #2 AWG STRANDED GREEN INSULATED COPPER CONDUCTOR EXTENDED AROUND THE PERIMETER OF THE EQUIPMENT AREA. ALL NON-TELECOMMUNICATIONS RELATED METALLIC OBJECTS FOUND WITHIN A SITE SHALL BE GROUNDED TO THE INTERIOR GROUND RING WITH #6 AWG STRANDED GREEN INSULATED CONDUCTOR. (ATT-TP-76416 7.6.4) BOND TO INTERIOR GROUND RING: #2 AWG SOLID TINNED COPPER WIRE PRIMARY BONDS SHALL BE PROVIDED AT LEAST AT FOUR POINTS ON THE INTERIOR GROUND RING, LOCATED AT THE CORNERS OF THE BUILDING. (ATT-TP-76416 7.5.2.2) GROUND ROD:8//,67('&233(5&/$'67((/0,1,080´',$0(7(5%<(,*+7 FEET LONG. ALL GROUND RODS MAY BE INSTALLED WITH INSPECTION SLEEVES. GROUND RODS SHALL BE DRIVEN TO THE DEPTH OF GROUND RING CONDUCTOR. (ATT-TP-76416 1.4 / 2.2.3.10) CELL REFERENCE GROUND BAR: POINT OF GROUND REFERENCE FOR ALL COMMUNICATIONS EQUIPMENT FRAMES. ALL BONDS ARE MADE WITH #2 AWG STRANDED GREEN INSULATED COPPER CONDUCTORS. BOND TO GROUND RING WITH (2) #2 SOLID TINNED COPPER CONDUCTORS. (ATT-TP-76416 7.6.7) HATCH PLATE GROUND BAR: BOND TO THE INTERIOR GROUND RING WITH TWO #2 AWG STRANDED GREEN INSULATED COPPER CONDUCTORS. WHEN A HATCH-PLATE AND A CELL REFERENCE GROUND BAR ARE BOTH PRESENT, THE CRGB MUST BE CONNECTED TO THE HATCH-PLATE AND TO THE INTERIOR GROUND RING USING TWO #2 AWG STRANDED GREEN INSULATED COPPER CONDUCTORS. EXTERIOR CABLE ENTRY PORT GROUND BARS: LOCATED AT THE ENTRANCE TO THE CELL SITE BUILDING. BOND TO GROUND RING WITH A #2 AWG SOLID TINNED COPPER CONDUCTORS WITH AN EXOTHERMIC WELD AND INSPECTION SLEEVE. (ATT-TP-76416 7.6.7.2) TOWER EXIT GROUND BAR: #2 AWG SOLID TINNED COPPER BOND TO THE TOWER GROUND RING. (ATT-TP-76416 7.5.5) TELCO GROUND BAR: BOND TO BOTH CELL REFERENCE GROUND BAR AND EXTERIOR GROUND RING. (ATT-TP-76416 7.6.8) FRAME BONDING: THE BONDING POINT FOR TELECOM EQUIPMENT FRAMES SHALL BE THE GROUND BUS THAT IS NOT ISOLATED FROM THE EQUIPMENTS METAL FRAMEWORK. BOND THE FRAME GROUND BUS OR SUPPLEMENTARY CONDUCTOR 727+(³,´6(&7,212)7+(&(//5()(5(1&(*5281'%$5 $7773 AND 7.8) INTERIOR UNIT BONDS: METAL FRAMES, CABINETS AND INDIVIDUAL METALLIC UNITS LOCATED WITH THE AREA OF THE INTERIOR GROUND RING REQUIRE A #6 AWG STRANDED GREEN INSULATED COPPER BOND TO THE INTERIOR GROUND RING. (ATT-TP-76416 7.12.3.1) FENCE AND GATE GROUNDING: METAL FENCES WITHIN 7 FEET OF THE EXTERIOR GROUND RING OR OBJECTS BONDED TO THE EXTERIOR GROUND RING SHALL BE BONDED TO THE GROUND RING WITH A #2 AWG SOLID TINNED COPPER CONDUCTOR AT AN INTERVAL NOT EXCEEDING 25 FEET. BONDS SHALL BE MADE AT EACH GATE POST AND ACROSS GATE OPENINGS. (ATT-TP-76416 7.12.2.2) EXTERIOR UNIT BONDS: METALLIC OBJECTS, EXTERNAL TO OR MOUNTED TO THE BUILDING, SHALL BE BONDED TO THE EXTERIOR GROUND RING. (ATT-TP-76416 7.12.2) ICE BRIDGE SUPPORTS: EACH ICE BRIDGE LEG SHALL BE BONDED TO THE GROUND RING WITH #2 AWG BARE TINNED COPPER CONDUCTOR. PROVIDE EXOTHERMIC WELDS AT BOTH THE ICE BRIDGE LEG AND BURIED GROUND RING. (ATT-TP-76416 7.4.2.6) DURING ALL DC POWER SYSTEM CHANGES INCLUDING DC SYSTEM CHANGE OUTS, RECTIFIER REPLACEMENTS OR ADDITIONS, BREAKER DISTRIBUTION CHANGES, BATTERY ADDITIONS, BATTERY REPLACEMENTS AND INSTALLATIONS OR CHANGES TO DC CONVERTER SYSTEMS IT SHALL BE REQUIRED THAT SERVICES CONTRACTORS VERIFY ALL DC POWER SYSTEMS ARE EQUIPPED WITH A MASTER DC SYSTEM RETURN GROUND CONDUCTOR FROM THE DC POWER SYSTEM COMMON RETURN BUS DIRECTLY CONNECTED TO THE CELL SITE REFERENCE GROUND BAR (CRGB) PER TP76300 SECTION H 6 AND TP76416 FIGURE 7-11 REQUIREMENTS. B C D E F G H J K L M N P Q F D J C E NOTES 1.GROUNDING IS SHOWN DIAGRAMMATICALLY ONLY. 2.CONTRACTOR SHALL GROUND ALL EQUIPMENT AS A COMPLETE SYSTEM. GROUNDING SHALL BE IN COMPLIANCE WITH NEC SECTION 250 AND AT&T GROUNDING AND BONDING REQUIREMENTS (ATT-TP-76416) AND MANUFACTURER'S SPECIFICATIONS. 3.ALL GROUND CONDUCTORS SHALL BE COPPER; NO ALUMINUM CONDUCTORS SHALL BE USED. LEGEND R M B A R E #2 AWG T NEW GPS ANTENNA #6 AWG GROUND (PROVIDED WITH KIT) #2 AWG TO GROUND RING LL #2 AWG 1 TYPICAL GROUNDING SCHEMATIC 6/14/21 FINAL CD'S NP 839612 CM IDL01003 IDL01003 1250 WEST USTICK ROAD MERIDIAN, ID 83646 161 Inverness Drive West 2nd floor Englewood, Colorado 80112 PREPARED FOR: REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: BU NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Tower Owner: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: A&E: at&t 2055 SOUTH STEARMAN DRIVE CHANDLER, AZ 85286 B RAD CENTER CHANGE04/23/21 A 4/07/21 PRELIMINARY CD'S C RAD CENTER CHANGE06/01/21 0 SUBMITTAL CD'S06/03/21 0A 6/14/21 SUBMITTAL CD'S TIM ALEX A N D E RSIGNED, EXPIRES, 28 FEB 2023 GROUNDING DETAILS G-3 DC/FIBER TO RRH SURGE PROTECTOR & OR FIBER POWER CONNECTOR DC AND FIBER TO SURGE PROTECTOR(S) MOUNT GROUNDING BUS BAR TO TOWER AT GROUND LEVEL WITH ISOLATION. MOUNT GROUNDING BUS BAR NEAR ANTENNA ARRAY WITHOUT ISOLATION. (2) #2 AWG GROUND WIRE TO RRH, TYP RRH(S), TYP LTE ANTENNA BOND RF BUS BAR(S) TO "I" SECTION 4"x30"x1/4" THICK COPPER GALVANIZED GROUND BAR "A" SECTION BONDED TO: xINTERIOR GROUND RING xEXTERNAL EARTH GROUND (BURIED GROUND RING) xMETALLIC COLD WATER PIPE (IF AVAILABLE) xBUILDING STEEL (IF AVAILABLE) EXOTHERMICALLY WELD #2 AWG BARE TINNED SOLID COPPER WIRE CONDUCTOR TO GROUND BAR. ROUTE CONDUCTOR TO BURIED GROUND RING AND PROVIDE PARALLEL EXOTHERMIC WELD INTERIOR GROUND RING DOUBLE CRIMP CONNECTION, TYP ISOLATOR, TYP UTILIZE GROUND KITS WITH #2 AWG AND 2-HOLE COMPRESSION LUGS UNLESS SPECIFIED OTHERWISE BOND DC BUS BAR(S) & POTENTIAL SURGE PRODUCING EQUIPMENT TO "P" SECTION NOTE: COAT ALL MECHANICAL CONNECTIONS WITH "NO-OX" OR APPROVED. WALL MOUNTING BRACKET "X" ~ VARIES #2 SOLID BARE TINNED COPPER WIRE CADWELD (TYPE-GL) NOTE: COAT ALL MECHANICAL CONNECTIONS WITH "NO-OX" OR APPROVED. GROUND KITS WITH LONG BARREL COMPRESSION DOUBLE LUGS AND INSPECTION WINDOW, ATTACH TO GROUND BAR X"x4"x1/4" THICK COPPER GALVANIZED GROUND BAR ISOLATOR (WHEN APPLICABLE) TYPE TA TYPE VN TYPE NC TYPE SS TYPE W TYPE VS TYPE VB TYPE PT TYPE GT TYPE GY TYPE GR TYPE GL NOTE: CADWELD "TYPES" SHOWN ABOVE ARE EXAMPLES - CONSULT WITH PROJECT MANAGER FOR SPECIFIC TYPES OF CADWELDS TO BE USED. 2 GROUNDING DETAILS 1 CAD WELD EXAMPLES 4 EXOTHERMIC WELD AND GROUND ROD WITH INSPECTION SLEEVE 1'-0"6" BELOW FROSTLINE OR 36" MIN6" BELOW FROST LINEOR 36" MIN1" MAX6" BELOW FROST LINEOR 36" MIN3 NOT USED 6/14/21 FINAL CD'S NP 839612 CM IDL01003 IDL01003 1250 WEST USTICK ROAD MERIDIAN, ID 83646 161 Inverness Drive West 2nd floor Englewood, Colorado 80112 PREPARED FOR: REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: BU NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Tower Owner: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: A&E: at&t 2055 SOUTH STEARMAN DRIVE CHANDLER, AZ 85286 B RAD CENTER CHANGE04/23/21 A 4/07/21 PRELIMINARY CD'S C RAD CENTER CHANGE06/01/21 0 SUBMITTAL CD'S06/03/21 0A 6/14/21 SUBMITTAL CD'S TIM ALEX A N D E RSIGNED, EXPIRES, 28 FEB 2023 GROUNDING DETAILS G-4 3 EXTERIOR TWO-HOLE LUG S/S NUT S/S LOCK WASHER S/S FLAT WASHER ‘[ EXTERNAL TOOTHED INSPECTION WINDOW IN BARREL, REQUIRED FOR ALL INTERIOR TWO-HOLE CONNECTORS 2'-6" MIN.(TYP)2 HVAC GROUND CONNECTION 1 NOT USED 5 NOT USED 4 SHELTER GROUND DETAIL36" MIN1" MAX12" MAX6" BELOW FROSTLINE OR 36" MIN12"6 NOT USED 9 TEST GROUND ROD WITH INSPECTION SLEEVE 8 TYPICAL BURIED GROUND ROD 7 EXTERIOR RECEPTACLE GROUNDING36" MIN. OR 6" BELOWFROSTLINEMAX. = 2X ROD LENGTH 16'-0"