Loading...
#405 Meridian Remodel - Interior Permit Plans Set, Approved by Meridian City - C-TI-2021-0029_072021OWNER MAVERIK, INC 185 SOUTH STATE STREET #800 SALT LAKE CITY, UT 84111 PHONE 801.936.5557 ARCHITECT, STRUCTURAL/MECHANICAL/ELECTRICAL ENGINEE R GPD GROUP PROFESSIONAL CORPORATION 520 SOUTH MAIN STREET #2531 AKRON, OH 44311 CONTACT: ALISSA COBB EMAIL: acobb@gpdgroup.com PHONE: 678-781-5069 CITY MAP STREET MAP APPLICABLE CODE: 2018 INTERNATIONAL BUILDING CODE (IBC) 2018 INTERNATIONAL MECHANICAL CODE (IMC) 2017 IDAHO STATE PLUMBING CODE (ISPC) 2018 INTERNATIONAL FIRE CODE (IFC) 2018 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) 2018 INTERNATIONAL FUEL AND GAS CODE (IFGC) 2017 NATIONAL ELECTRIC CODE (NEC) OCCUPANCY CLASSIFICATION: M DESCRIPTION: GAS STATION/CONVENIENCE STORE CONSTRUCTION TYPE: V-B BUILDING HEIGHT: 28' - 7" RETAIL AREA: 2,834 S.F. BUILDING AREA: 3,987 S.F. FIRE SPRINKLERS: NOT REQUIRED (PER IBC 2018 SECTION 903.2.7) FIRE RESISTANCE RATINGS OF EXTERIOR WALLS TABLE 601 AND 602 - NON-RATED OCCUPANT LOAD: 44 OCCUPANTS MERCANTILE: 2,834 S.F. @ 1 OCC. PER 60 S.F. = 47 OC CUPANTS KITCHEN : 579 S.F. @ 1 OCC. PER 200 S.F. = 3 OCCUPA NTS STORAGE: 264 S.F. @ 1 OCC. PER 300 S.F. = 1 OCCUPAN TS OFFICES: 85 S.F. @ 1 OCC. PER 100 S.F. = 1 OCCUPANT S EGRESS WIDTH REQUIRED: 44 OCC. @ .2" PER OCC. = 9" EGRESS WIDTH PROVIDED: 9' - 0" (1) 6'-0" (3'-0" PAIR) SWINGING DOORS AT STOREFRONT (1) 36" EXIT DOOR NEAR RESTROOMS. PLUMBING FIXTURES REQUIRED: PLUMBING FIXTURES PROVID ED: (1) MEN'S TOILET (1) MEN'S TOILET, (2) URINAL (1) WOMEN'S TOILET (3) WOMEN'S TOILET (1) MEN'S SINK (1) MEN'S SINK (1) WOMEN'S SINK (1) WOMEN'S SINK (1) DRINKING FOUNTAIN DRINKING FOUNTAIN: NOT REQUIRED (PER IPC 2018 SECTION 410.1) (1) SERVICE SINK (1) SERVICE SINK TILE EMSER TILE RENEE ANDERSON (801) 573-6772 MAVERIK@EMSER.COM & RENEEANDERSON@EMSER.COM ACCOUNT #: 1380974 PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY:APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSIO N OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.3/11/2021 10:53:07 AMCOVER SHEET 2020020.47 FINAL DRAWINGS 07/10/20 MA AC TYPE B REMODEL G0.01MAVERIK, INC.3202 W. USTICK RD.MERIDIAN, ID 83646MAVERIK C-STORE #405MAVERIK, INC. 3202 W. USTICK RD. MERIDIAN, ID 83646 TYPE B REMODEL MAVERIK C -STORE #405 N VICINITY MAPS DRAWING INDEX PROJECT DIRECTORYCODE SUMMARY NATIONAL ACCOUNTS P0.01 PLUMBING DEMOLITION PLAN P1.01 PLUMBING WASTE AND VENT PLAN P1.02 PLUMBING WATER PLAN P2.00 PLUMBING SCHEDULES P2.01 PLUMBING DETAILS P2.02 PLUMBING ISOMETRICS MECHANICAL M0.01 MECHANICAL LEGENDS & NOTES M1.01 MECHANICAL FLOOR PLAN ELECTRICAL E0.01 ELECTRICAL NOTES & SCHEDULES E3.00 ELECTRICAL POWER PLAN E3.02 ELECTRICAL LIGHTING PLAN E3.03 ELECTRICAL ROOF PLAN E6.00 ELECTRICAL SCHEDULES E6.01 PANEL SCHEDULES GENERAL G0.01 COVER SHEET G0.02 GENERAL INFORMATION ARCHITECTURAL AD.01 DEMOLITION FLOOR PLAN AD.02 DEMOLITION REFLECTED CEILING PLAN A1.01 DIMENSION FLOOR PLAN A1.02 REFERENCE AND FINISH FLOOR PLAN A1.03 EQUIPMENT FLOOR PLAN A1.04 EQUIPMENT SCHEDULE A1.05 REFLECTED CEILING PLAN A2.51 INTERIOR ELEVATIONS & WALL TYPES A4.01 ENLARGED RESTROOM PLAN AND ELEVATIONS A4.02 ENLARGED RETAIL PLANS & ELEVATIONS A4.03 ENLARGED RETAIL PLANS & ELEVATIONS A5.11 DETAILS A6.03 FINISH & MATERIAL SCHEDULES STRUCTURAL S0.01 GEN. STRUCTURAL NOTES S0.02 GEN. STRUCTURAL NOTES & SPECIAL INSPECTIONS S0.03 SCHEDULE OF SPECIAL INSPECTIONS S1.11 PARTIAL ROOF FRAMING PLAN S5.10 FOUNDATION & FRAMING DETAILS PLUMBING P0.00 PLUMBING LEGENDS & NOTES GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 2 AHJ COMMENTS 3/15/21 2 2 03/15/21 4 1 2 3 A252 CLOUD INDICATES DRAWING REVISION AREA ROOM NAME ROOM NUMBER SHEET NUMBER SECTION NUMBER ELEVATION NUMBER REVISION NUMBER ELEVATION NUMBER SHEET WHERE DRAWN SHEET NUMBER DETAIL NUMBER SHEET NUMBER 00.00 BUILDING SECTION WALL SECTION EXTERIOR ELEVATION INTERIOR ELEVATION PARTITION TYPE A -222 A2 NUM ROOM NAME 101 A KEYED NOTE GLAZING TYPE DOOR TAG A1 A-101 A1 A-101 SHEET NUMBER SECTION NUMBER SHEET NUMBER DETAIL NUMBER DETAIL SECTION DETAIL ROOM TAG REVISION TAG A1 A-101 SHADE INDICATES ELEVATED WALL 1 A -222 A2 A 1i DIVISION NUMBER KEYNOTE NUMBER GYPSUM BOARD OR CONCRETE SURFACE HATCH PATTERN BELOW INDICATES REPRESENTATION OF BUILDING MATERIALS IN BUILDING SECTIONS, WALL SECTIONS AND DETAILS. CONCRETE STUD WALL GRAVEL COMPACTED FILL AND/OR EARTH CMU (CONCRETE MASONRY UNIT) BATT INSULATION RIGID INSULATION PAPER TOWEL DISPENSER SOAP DISPENSER FIRE EXTINGUISHER CABINET HIGHEST OPERABLE PARTS SANITARY NAPKIN DISPENSER TOILET PARTITION URINAL PARTITION12"48"12"58" U.N.O.BABY CHANGING STATION HAND DRYER MIRROR WITH FRAME MOP RACKSURFACE3'-4" MAXTO REFLECTIVE60"MAX.48"FLOOR LINE ACCESSIBLE WATER CLOSET FLOOR LINE ACCESSIBLE LAVATORY MIN. 15"9" MIN6" MAX (TOE CLEAR.)(KNEE CLEAR.) 8" MIN (TOE CLEAR. DEPTH) 17" - 25"2'-3" MINWALL NOTE: EXPOSED PIPE SHALL BE INSULATED (NO SHARP OR ABRASIVE SURFACES BELOW LAVATORY)TO REFLECTIVE SURFACE40" MAX34" MAXSANITARY NAPKIN DISPOSAL 2"FACE OF WALL FACE OF WALL 2"17"-19"7"-9" GRAB BAR 16" - 18" 33" - 36" MIN 18"33" - 36"44" MAX17"-19" 12" MIN. MAX. 1' - 0"42" MIN 24" MIN. 39" - 41"39" - 41" 34" MAX. 11" MIN. 54" MIN 15" MINWHERE SINGLE DOOR OCCURS, MOUNT SIGNS ALONG THE LATCH SIDE. REFER TO CHAPTER 7 OF 2010 ADA STANDARDS FOR ADDITIONAL REQUIREMENTS. WHERE OPENING WITH NO DOOR OCCURS, MOUNT SIGNS, WHERE SHOWN ON SHEET A1.02 REFERENCE AND FINISH FLOOR PLAN 9" MIN. WOMEN NAME RESTROOM SIGN ACCORDING TO THE CORRESPONDING ROOM TAG LOCATED ON SHEET A1.02 6" MIN. 48" MIN.LOCATION OF GENDER PICTOGRAM BRAILLE PER 2010 ADA STANDARDS SECTION 703.3, NAME ACCORDING TO CORRESPONDING ROOM TAGS ON SHEET A1.02 5/8"-2"PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY: APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSIO N OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.10/8/2020 11:29:38 AMGENERAL INFORMATION 2020020.47 FINAL DRAWINGS 07/10/20 MA AC TYPE B REMODEL G0.02MAVERIK, INC.3202 W. USTICK RD.MERIDIAN, ID 83646MAVERIK C-STORE #405GENERAL NOTES ABBREVIATIONSMATERIAL LEGEND SYMBOLS LEGEND 1. GENERAL: BASIC CONTRACT DEFINITIONS ARE INCLUDED IN THE CONDITIONS OF THE CONTRACT. 2. "APPROVED": WHEN USED TO CONVEY ARCHITECT'S ACTION ON CONTRACTOR'S SUBMITTALS, APPLICATIONS, AND REQUESTS, "APPROVED" IS LIMITED TO ARCHITECT'S DUTIES AND RESPONSIBILITIES AS STATED IN THE CONDITIONS OF THE CONTRACT. 3. "DIRECTED": A COMMAND OR INSTRUCTION BY ARCHITECT. OTHER TERMS INCLUDING "REQUESTED," "AUTHORIZED," "SELECTED," "REQUIRED," AND "PERMITTED" HAVE THE SAME MEANING AS "DIRECTED." 4. "INDICATED": REQUIREMENTS EXPRESSED BY GRAPHIC REPRESENTATIONS OR IN WRITTEN FORM ON DRAWINGS, IN SPECIFICATIONS, AND IN OTHER CONTRACT DOCUMENTS. OTHER TERMS INCLUDING "SHOWN," "NOTED," "SCHEDULED," AND "SPECIFIED" HAVE THE SAME MEANING AS "INDICATED." 5. "REGULATIONS": LAWS, ORDINANCES, STATUTES, AND LAWFUL ORDERS ISSUED BY AUTHORITIES HAVING JURISDICTION, AND RULES, CONVENTIONS, AND AGREEMENTS WITHIN THE CONSTRUCTION INDUSTRY THAT CONTROL PERFORMANCE OF THE WORK. 6. "FURNISH": SUPPLY AND DELIVER TO PROJECT SITE, READY FOR UNLOADING, UNPACKING, ASSEMBLY, INSTALLATION, AND SIMILAR OPERATIONS. 7. "INSTALL": UNLOAD, TEMPORARILY STORE, UNPACK, ASSEMBLE, ERECT, PLACE, ANCHOR, APPLY, WORK TO DIMENSION, FINISH, CURE, PROTECT, CLEAN, AND SIMILAR OPERATIONS AT PROJECT SITE. 8. "PROVIDE": FURNISH AND INSTALL, COMPLETE AND READY FOR THE INTENDED USE. 9. "PROJECT SITE": SPACE AVAILABLE FOR PERFORMING CONSTRUCTION ACTIVITIES. THE EXTENT OF PROJECT SITE IS SHOWN ON DRAWINGS AND MAY OR MAY NOT BE IDENTICAL WITH THE DESCRIPTION OF THE LAND ON WHICH PROJECT IS TO BE BUILT. DEFINITIONS TYPICAL MOUNTING HEIGHTS ADA AMERICANS WITH DISABILITIES ACT AFF ABOVE FINISH FLOOR B.O. BOTTOM OF CMU CONCRETE MASONRY UNIT CONC. CONCRETE CONT. CONTINUOUS D.O.T. DEPARTMENT OF TRANSPORTATION DIA DIAMETER EIFS EXTERIOR INSULATED FINISH SYSTEM EQ EQUAL FRP FIBERGLASS REINFORCED PANEL G.C. GENERAL CONTRACTOR IBC INTERNATIONAL BUILDING CODE MAX MAXIMUM MIN MINIMUM NIC NOT IN CONTRACT O.C. ON CENTER P.O.S. POINT OF SALE SIM SIMILAR SPEC SPECIFICATION SS STAINLESS STEEL T.O. TOP OF TYP TYPICAL U.N.O. UNLESS NOTED OTHERWISE W/ WITH 1. ALL INTERIOR WALLS TO WRAPPED WITH 5/8" GYPSUM WALL BOARD, TAPED, FILLED, AND FINISHED AS PER ROOM FINISH SCHEDULE AND OWNER. 2. ALL PRODUCTS ON THIS PROJECT SHALL BE INSTALLED PER MANUFACTURER'S REQUIREMENTS AND SPECIFICATIONS. ACCESSIBLE SIGNAGE GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 10/09/20 H H 33 2 2 1 1 E E D D C C A A B B F F 2.1 2.1 2.2 2.2 02.7202.03 02.03 02.03 02.08 02.05 02.08 TYP. 02.29 02.09 02.09 02.73 02.08 02.08 02.08 02.10 02.07 02.10 02.74 02.16 02.76 02.16 02.76 02.0702.07 02.11 02.11 103 MEN'S 102 WOMEN'S 113 ELECTRICAL ROOM 112 STORAGE 105 DELI PREP 101 RETAIL 111 35° BEVERAGE COOLER 110 30° BEER COOLER 109 OFFICE 106 KITCHEN SERVICE 107 35° STOR COOLER 108 -10° FREEZER 02.1102.1102.11 02.11 02.01 02.12 02.11 02.79 02.80 02.12 02.81 02.86 02.13 02.79 02.86 02.08 G G 02.01 02.01 02.09 02.01 02.16 02.79 02.91 02.13 02.91 02.86 02.79 02.09 02.01 02.06 02.82 115 STORAGE 104 EXIT HALLWAY 02.09 02.01 02.01 02.08 02.82 02.82 02.105 02.105 V.I.F. 2' - 0"V.I.F.10' - 0"02.85 02.12 15' - 9 7/8"2' - 8 1/2"8' - 1 5/8"7' - 1 1/2"4' - 2 1/2"2' - 8 1/2" 7' - 0"14' - 1 3/4" 6' - 4 3/4" 2' - 7 3/8" 8' - 2 3/8"3' - 2"6' - 0"02.09 02.10 02.78 02.80 02.01 02.02 02.78 02.78 02.07 02.07 02.12 02.74 02.16 02.12 02.82 02.82 02.03 02.78 4' - 4 3/8" 02.09 02.78 GENERAL NOTES 1. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS, MATERIALS, FINISHES, AND DIMENSIONS BEFORE AND AFTER DEMOLITION. 2. CONTRACTOR TO PROTECT ALL ITEMS TO REMAIN FROM DAMAGE. 3. SEE STRUCTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION. 4. AT WALL TRANSITION FROM NEW TO EXISTING WALLS PATCH, REPAIR AND/OR REPLACE GYP. BOARD AS REQUIRED TO PROVIDE FLUSH TRANSITION BETWEEN NEW AND EXISTING SURFACES. 5. PATCH / REPAIR / PREP WALLS AS NECESSARY TO RECEIVE NEW PAINT AT LOCATIONS WHERE EQUIPMENT WAS REMOVED. 6. ALL DIMENSIONS TO EXISTING WALLS ARE TO FACE OF FINISH, U.N.O. PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY: APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSIO N OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.10/8/2020 11:29:31 AMDEMOLITION FLOOR PLAN 2020020.47 FINAL DRAWINGS 07/10/20 MA AC TYPE B REMODEL AD.01MAVERIK, INC.3202 W. USTICK RD.MERIDIAN, ID 83646MAVERIK C-STORE #40502.81 REMOVE EXISTING COUNTER. BASE MILLWORK TO REMAIN. PREP FOR NEW COUNTERTOP 02.82 NO WORK IN THIS AREA 02.85 HATCHED AREA INDICATES APPROXIMATE CONCRETE SLAB TO BE SAW CUT AND REMOVED FOR NEW POWER FROM EXISTING J-BOX IN WALL TO NEW MILLWORK. GC TO FIELD VERIFY LOCATION OF J-BOX AND COORDINATE LOCATION OF TRENCHING. SEE STRUCTURAL DRAWINGS FOR SLAB PATCHING REQUIREMENTS 02.86 REMOVE EXISTING FLOORING AND ADHESIVES TO SLAB. PREP FOR NEW TILE INSTALLATION 02.91 REMOVE EXISTING VANITY AND SINK. MAINTAIN CONNECTION FOR NEW 02.105 REMOVE EXISTING DOOR, FRAME AND HARDWARE. PREP OPENING TO RECIEVE NEW FRAME. 02.72 REMOVE EXISTING DOOR, FRAME AND HARDWARE. INFILL WITH WALL STRUCTURE AND FINISH TO MATCH ADJACENT 02.73 EXISTING HOOD TO REMAIN 02.74 REMOVE WALL TILE IN RESTROOMS. REPAIR OR REPLACE SUBSTRATE AS REQUIRED. PREP WALLS TO RECEIVE NEW TILE AND GRAPHIC 02.76 EXISTING TOILETS/URINAL TO BE REUSED. DISCONNECT/TAKE DOWN AND PROTECT FOR NEW WALL AND FLOOR FINISH INSTALLS. RECONNECT/REINSTALL IN SAME PLACE 02.78 HATCHED AREA INDICATES APPROXIMATE CONCRETE SLAB TO BE SAW CUT AND REMOVED FOR NEW UTILITIES. FIELD VERIFY EXTENTS AND COORDINATE WITH PLUMBING DRAWINGS. SEE STRUCTURAL DRAWINGS FOR SLAB PATCHING REQUIREMENTS 02.79 REMOVE EXISTING BASE. CLEAN AND PREP FOR NEW 02.80 REMOVE EXISTING ROOF TOP ICEMAKER CONDENSER. PATCH AND REPAIR ROOF AS REQUIRED TO ENSURE WATER TIGHT 02.08 REMOVE EQUIPMENT. SEE PLUMBING & ELECTRICAL DRAWINGS FOR ADDITIONAL DEMO SCOPE. COORDINATE REMOVAL WITH OWNER 02.09 REMOVE MILLWORK IN ITS ENTIRETY AS WELL AS ALL EQUIPMENT/FIXTURES ATOP OR INSIDE MILLWORK. COORDINATE EQUIPMENT REMOVAL WITH OWNER. COORDINATE ELECTRICAL AND PLUMBING REMOVAL WITH NEW EQUIPMENT REQUIREMENTS 02.10 REMOVE PLUMBING FIXTURE. COORDINATE DRAIN AND WATER REMOVAL WITH NEW PLUMBING LOCATION(S) 02.11 EXISTING WALL TO REMAIN; PROTECT DURING CONSTRUCTION 02.12 REMOVE WALL GRAPHICS IN RETAIL AREA, BEER COOLER, RESTROOMS AND EXIT HALL; PREP WALLS FOR NEW GRAPHICS 02.13 REMOVE TOILET PARTITIONS AND ACCESSORIES 02.16 PREP FLOOR FOR NEW TILE INSTALLATION 02.29 REMOVE SHELVING FROM COOLER; COORDINATE WITH OWNER 02.01 SAW CUT AROUND EXISTING FLOOR SINK AND REMOVE EXISTING FLOOR SINK AND CAP BELOW SLAB. FIELD VERIFY EXTENTS AND PATCH WITH CONCRETE. SEE STRUCTURAL DRAWINGS FOR PATCHING REQUIREMENTS 02.02 SAW CUT AROUND EXISTING POWER/DATA CONDUIT AND REMOVE EXISTING POWER AND DATA AND CAP BELOW SLAB. FIELD VERIFY EXTENTS AND PATCH WITH CONCRETE. SEE STRUCTURAL DRAWINGS FOR PATCHING REQUIREMENTS 02.03 REMOVE GONDOLA. COORDINATE REMOVAL WITH OWNER 02.05 REMOVE COUNTERTOP AND CABINETS. COORDINATE POWER AND DATA REMOVAL WITH NEW CASH WRAP REQUIREMENTS 02.06 REMOVE CASH WRAP RAISED PLATFORM 02.07 REMOVE WALL IN ITS ENTIRETY. WHERE REMOVED WALL INTERSECTS EXISTING WALL TO REMAIN, PATCH REMAINING WALL TO MATCH ADJACENT WALL. RELOCATE ANY EXISTING PLUMBING/ELECTRICAL AS REQUIRED FOR NEW LAYOUT KEYED NOTES SCALE:1/4" = 1'-0"1 DEMOLITION FLOOR PLAN N GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 10/09/20 H H 33 2 2 1 1 E E D D C C A A B B F F 2.1 2.1 2.2 2.2 02.43 TYP. 02.43 TYP. 02.43 TYP. 02.43 TYP. 02.43 02.73 103 MEN'S 102 WOMEN'S 113 ELECTRICAL ROOM 112 STORAGE 105 DELI PREP 101 RETAIL 111 35° BEVERAGE COOLER 110 30° BEER COOLER 109 OFFICE 106 KITCHEN SERVICE 107 35° STOR COOLER 108 -10° FREEZER 02.43 TYP. 02.43 02.83 02.83 02.83 02.83 104 EXIT HALLWAY 02.88 TYP. 02.44 TYP. 02.44 G G 02.83 02.47 02.47 1' - 4 7/8"11 3/8"2' - 7 1/8"1' - 8 1/8" 02.77 02.44 02.44 115 STORAGE 02.83 02.83 02.83 02.83 02.44 08.01 TYP. 08.01 02.112 02.112 02.100 02.100 PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY: APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSIO N OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.10/8/2020 11:29:34 AMDEMOLITION REFLECTED CEILING PLAN 2020020.47 FINAL DRAWINGS 07/10/20 PR AC TYPE B REMODEL AD.02MAVERIK, INC.3202 W. USTICK RD.MERIDIAN, ID 83646MAVERIK C-STORE #405SCALE:1/4" = 1'-0"1 DEMOLITION REFLECTED CEILING PLAN GENERAL NOTES 02.100 REPAIR EXISTING CEILING AS REQUIRED AT DEMOLISHED WALL. 02.112 EXISTING DOOR HEADER TO REMAIN. SUPPORT AS NECESSARY FOR NEW OPENING LOCATION. 08.01 DASHED LINE REPRESENTS SKYLIGHT ABOVE, SEE REFLECTED CEILING PLAN 02.43 EXISTING LIGHT FIXTURE TO REMAIN; PROTECT DURING CONSTRUCTION 02.44 REMOVE LIGHT FIXTURE 02.47 EXISTING CEILING TO REMAIN 02.73 EXISTING HOOD TO REMAIN 02.77 HATCHED AREA INDICATES ACOUSTIC CEILING TILE AND GRID TO BE REPLACED 02.83 NO CEILING WORK IN THIS AREA 02.88 REMOVE EXISTING CEILING MOUNTED KAYAKS AND SNOW BOARDS COMPLETELY. EXISTING TREES TO REMAIN. PROTECT DURING DEMO AND CONSTRUCTION. 1. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS, MATERIALS, FINISHES, AND DIMENSIONS BEFORE AND AFTER DEMOLITION. 2. CONTRACTOR TO PROTECT ALL ITEMS TO REMAIN FROM DAMAGE. 3. SEE STRUCTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION. 4. AT WALL TRANSITION FROM NEW TO EXISTING WALLS PATCH, REPAIR AND/OR REPLACE GYP. BOARD AS REQUIRED TO PROVIDE FLUSH TRANSITION BETWEEN NEW AND EXISTING SURFACES. 5. PATCH / REPAIR / PREP WALLS AS NECESSARY TO RECEIVE NEW PAINT AT LOCATIONS WHERE EQUIPMENT WAS REMOVED. 6. ALL DIMENSIONS TO EXISTING WALLS ARE TO FACE OF FINISH, U.N.O. N KEYED NOTES GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 10/09/20 H H 33 2 2 1 1 E E D D C C A A B B F F 2.1 2.1 2.2 2.21' - 2 1/2"V.I.F.5' - 11"HOLD 19' - 8 1/8"4 3/4"3' - 0"6' - 9 5/8" D3 D3 E3 12' - 9 3/8" 06.29 05.72 103 MEN'S 102 WOMEN'S 113 ELECTRICAL ROOM 112 STORAGE 105 DELI PREP 101 RETAIL 111 35° BEVERAGE COOLER 110 30° BEER COOLER 109 OFFICE 106 KITCHEN SERVICE 107 35° STOR COOLER 108 -10° FREEZER 6' - 2 3/8"3' - 0 1/4"7' - 7 5/8"05.73 ALIGN G G 09.13 D62' - 9 5/8" E3 D3 3' - 9"9' - 7 3/4" C3 10' - 0"2' - 0"15' - 9 7/8"2' - 8 1/2"8' - 1 5/8"7' - 1 1/2"4' - 2 1/2"2' - 8 1/2"7' - 0"14' - 1 3/4"6' - 0"3' - 2"3' - 4 3/4" 2' - 7 3/8"1' - 10"8' - 3 1/4"5' - 10 1/8"05.63 05.63 05.63 03.14 TYP. 03.14 05.63 6' - 4 3/4"2' - 7 3/8"8' - 2 3/8" CLEAR 11' - 4" 4' - 4 5/8" 03.14 03.14 03.14 09.2509.2509.25 09.7009.70 09.2509.2509.25 09.70 05.72 05.72 03.14 03.14 6"10' - 0 3/8"2' - 0" 12' - 3 5/8"6"2' - 0"2' - 0"3' - 10"2' - 0"PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY:APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSIO N OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.10/8/2020 11:28:42 AMDIMENSION FLOOR PLAN 2020020.47 FINAL DRAWINGS 07/10/20 PR AC TYPE B REMODEL A1.01MAVERIK, INC.3202 W. USTICK RD.MERIDIAN, ID 83646MAVERIK C-STORE #405SCALE:1/4" = 1'-0"1 PROPOSED FLOOR PLAN GENERAL NOTESKEYED NOTES 06.29 PARTIAL HEIGHT WALL TO BE PROVIDED AND INSTALLED BY CABINET FABRICATOR 09.13 GYPSUM WALL BOARD WITH LEVEL 3 FINISH FOR SUEDE WALL GRAPHICS, PAINTED P-1 09.25 TOILET PARTITION, SEE SCHEDULE. ALL PANELS TO BE 58" TALL, MOUNT TO FLOOR/CEILING/WALL, PROVIDE BLOCKING AS REQUIRED. PARTITIONS ADJACENT TO THE URINAL TO BE MOUNTED WITH TOP AT 60" A.F.F. MINIMUM 09.70 TOILET PARTITION, SEE SCHEDULE. END PANELS TO BE 70" TALL MOUNTED AT 0'-0" AFF, MOUNT TO FLOOR/CEILING/WALL, PROVIDE BLOCKING AS REQUIRED 03.14 HATCHED AREA INDICATES NEW CONCRETE TO MATCH EXISTING, SEE DETAILS 8, 9 AND 10/S5.10 ON STRUCTURAL DRAWINGS. PROVIDE NEW TILE TO MATCH EXISTING. SEE AD.01 FOR DIMENSIONS. 05.63 PROVIDE STAINLESS STEEL SINK SURROUND IN CABINET AT FLOOR SINK LOCATION, SEE DETAIL 4/A5.11. SEE PLUMBING PLANS FOR FLOOR SINK LOCATIONS 05.72 INFILL WALL WHERE DOOR HAS BEEN REMOVED. MATCH EXISTING WALL STRUCTURE AND FINISH 05.73 PROVIDE STAINLESS STEEL PIPE APRON (PLATE) IN CABINET AT CONDUIT PENETRATION LOCATION. SEE DETAIL 2/A5.11. SEE PLUMBING PLANS FOR CONDUIT LOCATIONS GENERAL NOTES 9. ALL CORNER GUARDS TO BE MOUNTED ON THE FINISHED FLOORING. CONT. CAULK BETWEEN THE GUARD AND FLOORING AND THE GUARD AND THE RUBBER BASE. 10. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS. NOTIFY ARCHITECT IF VARIATIONS IN EXISTING CONDITIONS OCCUR. 11. CONTRACTOR TO VERIFY ALL CABINETRY COLORS WITH MAVERIK PROJECT MANAGER. 1. ALL PENETRATIONS IN CABINETRY TO BE CAULKED AND SEALED. 2. CONTRACTOR IS RESPONSIBLE FOR PROTECTING THE CONCRETE FLOOR AND GLASS DURING CONSTRUCTION. 3. SEE EQUIPMENT PLAN - SHEET A1.03, WALL TYPES AND PLAN ON SHEETS A1.01, A5.01. 4. ALL GRID LINES ARE INDICATED AT EDGE OF STUD. 5. ALL DIMENSIONS TO EXISTING WALLS ARE TO FACE OF FINISH, U.N.O. 6. ALL DIMENSIONS TO NEW WALLS ARE TO FACE OF STUD, U.N.O. 7. SEE SHEET A6.03 FOR FINISH SCHEDULE. 8. PROVIDE CRACK-SUPPRESSION MEMBRANE AT ALL TILE LOCATIONS. N GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 10/09/20 H H 33 2 2 1 1 E E D D C C A A A2.51 2 1 B B F F 2.1 2.1 2.2 2.2 4' - 0"4' - 0"4' - 0"35' - 5 7/8"5' - 10 1/2"14' - 0 7/8"23' - 9 5/8"5' - 8 3/8"13' - 0 1/8"3' - 4 1/8"4' - 0"21' - 8"21' - 7 1/4" 103 MEN'S CT-4 102 WOMEN'S CT-4 104 EXIT HALLWAY CT-4 101 RETAIL CT-4 112 STORAGE 113 ELECTRICAL ROOM 105 DELI PREP CT-2 107 35° STOR COOLER 108 -10° FREEZER 106 KITCHEN SERVICE CT-2 109 OFFICE 110 30° BEER COOLER CT-4 111 35° BEVERAGE COOLER 09.05 A4.02 1 A4.02 6 A4.02 10 A4.03 1 A4.03 10 A4.03 6 A4.03 15 ABOVE ABOVE ABOVE ABOVE ABOVE INFILL TO MATCH EXISTING 10.2410.24 10.24 10.22 12 A5.11 09.05 10.02 10.02 A4.03 9 10.5110.51 10.1910.1910.19 10.5210.52 10.51 A4.01 1 06.07 06.07 06.07 06.07 06.07 06.07 G G 10.19 10.19 115 STORAGE CT-2 10.5210.52 06.07 06.07 06.07 A4.02 9 06.0745°45°101 06.07 102 103 10.51 10.24 PREP WALL FOR LEVEL 4 FINISH FOR PRESSURE SENSITIVE WALL GRAPHICS, PAINTED P-1. PROVIDE CLEAR BRA PROTECTIVE COATING OVER GRAPHIC UP TO 30" IN EXIT HALLWAY ONLY FRP LOCATIONS WALL TILE LOCATIONS CORNER GUARD LOCATIONS PREP WALL FOR LEVEL 3 FINISH FOR SUEDE WALL GRAPHICS, PAINTED P-1 PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY: APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSIO N OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.10/8/2020 11:28:49 AMREFERENCE AND FINISH FLOOR PLAN 2020020.47 FINAL DRAWINGS 07/10/20 PR AC TYPE B REMODEL A1.02MAVERIK, INC.3202 W. USTICK RD.MERIDIAN, ID 83646MAVERIK C-STORE #405SCALE:1/4" = 1'-0"1 REFERENCE FLOOR PLAN GENERAL NOTESKEYED NOTES 10.51 CORNER GUARD, TO 10'-0" A.F.F. INSTALL CORNER BEADS OVER WALL MATERIAL. STOP RUBBER WALL BASE AT CORNER GUARD 10.52 CORNER GUARD, TO BOTTOM OF WALL CAP 06.07 CASEWORK PROVIDED AND INSTALLED BY OWNER'S VENDOR 09.05 SLOPED TRANSITION STRIP. SCHLUTER-RENO-RAMP OR EQUAL 10.02 ADA COMPLIANT WALL MOUNTED RESTROOM SIGN, SEE SHEET G0.02 FOR REQUIREMENTS 10.19 CORNER GUARD, TO UNDERSIDE OF SOFFIT. INSTALL CORNER GUARDS OVER WALL MATERIAL. STOP RUBBER WALL BASE AT CORNER GUARD 10.22 CORNER GUARD, TO 7'-6" A.F.F. INSTALL CORNER BEADS OVER WALL MATERIAL. STOP RUBBER WALL BASE AT CORNER GUARD 10.24 CORNER GUARD, TO TOP OF TILE OR FRP, INSTALL CORNER BEADS OVER WALL MATERIAL. STOP RUBBER WALL BASE AT CORNER GUARD GENERAL NOTES 9. ALL CORNER GUARDS TO BE MOUNTED ON THE FINISHED FLOORING. CONT. CAULK BETWEEN THE GUARD AND FLOORING AND THE GUARD AND THE RUBBER BASE. 10. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS. NOTIFY ARCHITECT IF VARIATIONS IN EXISTING CONDITIONS OCCUR. 11. CONTRACTOR TO VERIFY ALL CABINETRY COLORS WITH MAVERIK PROJECT MANAGER. 1. ALL PENETRATIONS IN CABINETRY TO BE CAULKED AND SEALED. 2. CONTRACTOR IS RESPONSIBLE FOR PROTECTING THE CONCRETE FLOOR AND GLASS DURING CONSTRUCTION. 3. SEE EQUIPMENT PLAN - SHEET A1.03, WALL TYPES AND PLAN ON SHEETS A1.01, A5.01. 4. ALL GRID LINES ARE INDICATED AT EDGE OF STUD. 5. ALL DIMENSIONS TO EXISTING WALLS ARE TO FACE OF FINISH, U.N.O. 6. ALL DIMENSIONS TO NEW WALLS ARE TO FACE OF STUD, U.N.O. 7. SEE SHEET A6.03 FOR FINISH SCHEDULE. 8. PROVIDE CRACK-SUPPRESSION MEMBRANE AT ALL TILE LOCATIONS. SYMBOL LEGEND N GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 10/09/20 H H 33 2 2 1 1 E E D D C C A A 103 MEN'S 109 OFFICE 104 EXIT HALLWAY 102 WOMEN'S112 STORAGE 101 RETAIL 105 DELI PREP 106 KITCHEN SERVICE 110 30° BEER COOLER 111 35° BEVERAGE COOLER 107 35° STOR COOLER 108 -10° FREEZER B B F F 2.1 2.1 2.2 2.2 33 33C 21 18 72.172.1 95 96 8 8 8 7 7 15 N49 13 14 16 110 N102 N102 4 51 N63A 113 ELECTRICAL ROOM 11.05 11.05 11.05 11.051' - 6"4' - 0"4' - 0"4' - 0"1' - 6"3' - 0"3' - 0"3' - 0"1' - 6"4' - 0"1' - 6"1' - 6"4' - 0"4' - 0"4' - 0"1' - 6"3' - 0"1' - 6"4' - 0"4' - 0"1' - 6"N31 N31 N31 N31 N31 N31 N31 TYP. 12.03 N106 N69 N71 N71 09.35 23 N69 N69 N69 N67N67 N67N67 42 42 N69 42 5151N63A 42 46 112 112 N69 N63A N65 N63D N66 N63D N63D N62 N63A N63D N66 N63D N63D N62 09.35 V.I.F.30' - 11 1/2"V.I.F. 9' - 1 3/4" P5 2' - 8"2' - 8" 48 N110 N110 G G 115 STORAGE 22 109 111 97 97 16 N101 N105 N109 22 20A N33 108 99 99 N95 N95 N95 N95 11 N9 N9 N9 9C 9C N9 N9 N9 514' - 0"1' - 6" N63A N50 N65 N62 N66 N50 P5 P3 P3 P2 P2 N66 N62 P2 P2 P2 N66 N62 N65 '8' N63C N63C SCALE:1/4" = 1'-0"1 EQUIPMENT FLOOR PLAN 09.35 SOLID SURFACE COUNTERTOP, SEE DETAIL ON 14/A4.02 AND SEE SCHEDULE ON SHEET A6.03 11.05 OWNER PROVIDED EQUIPMENT 12.03 TABLE/BAR SEATING KEYED NOTES GENERAL NOTES 1. REFER TO SHEET A1.04 FOR EQUIPMENT SCHEDULE 2. SEE MECHANICAL FOR ROOF MOUNTED EQUIPMENT. REFER TO DETAIL 13/A5.11 FOR CURB DETAIL. PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY: APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSIO N OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.10/8/2020 11:28:51 AMEQUIPMENT FLOOR PLAN 2020020.47 FINAL DRAWINGS 07/10/20 PR AC TYPE B REMODEL A1.03MAVERIK, INC.3202 W. USTICK RD.MERIDIAN, ID 83646MAVERIK C-STORE #405N GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 10/09/20 EQUIPMENT SCHEDULE ITEM CountDESCRIPTION LOCATION MODEL/MFG. DIMENSIONS SUPPLIEDINSTALLEDNOTES: ELECTRICAL PLUMBING NOTE:NOTES: 4 1 ICE/BEVERAGE DISPENSER DRINK WALL FLAVOR SELECT/ FS60 O V 7 2 DISPLAY WARMERS COFFEE/DRINK ISLAND HATCO GRSDS-36T 52"x24.29"x32.40"O GC 8 3 FRESH FOODS CASE HOT DOG COUNTER O GC 9C 2 BUNN DUAL THERMOFRESH COFFEE COUNTER DUAL THERMO-FRESH 21.8"x20.2"x35.7" O GC/O ELECTRICIAN TO SUPPLY AND INSTALL ELECTRICAL CORD AND CORD CAP 11 1 CAPPUCCINO MACHINE COFFEE COUNTER Bunn iMix-5S 19.3"x23.9"x34.36" O GC 13 1 CONDIMENT DROP-IN HOT DOG COUNTER RANDELL-9943SCA 43-3/8" x 26" x 27-1/2" O GC INTERNAL CONDENSER AND COMPRESSOR NEMA 5-15-PLUG REQUIRES VENTS; SEE DRAWINGS GC TO PROVIDE CUTOUT; SEE DWGS 14 1 MICROWAVE OVEN HOT DOG COUNTER SANASONIC-NE-1024 20-1/8" x 16-9/16" x 12" O GC NEMA .5-15 PORORNEMA .5-2 OR NEMA 5-15 PLUG 15 1 HOT DOG ROLLER GRILL HOT DOG COUNTER SILVERSTONE-8075S 35-1/2" x 25-3/4" x 7" O GC 16 2 NACHO MACHINE HOT DOG COUNTER GEHL DUO 18" x 17" x 35" O GC 18 1 QUIETQUBE ICE MAKER KITCHEN SERVICE HOSHIZAKI 30" x 24" x 32-7/8" O GC SITS ABOVE #4 ON SOFFIT ABOVE CONNECTED TO #18A-REMOTE CONDENSER 20A 1 OVEN/RACK COFFEE PREP NU-VU-OP-4/8M 30" X 35-1/2" X 78-1/4" O GC 21 1 ICE MAKER ( OVER BEV. DISP.) DRINK WALL N13 22R-32 SCOTSMAN PRODIGY PLUS O GC SITS ABOVE #4 (ON SOFFIT ABOVE0 CONNECTED TO #18A-REMOTE CONDENSER 22 2 FOOD PREP UNIT DELI PREP RANDELL O GC 23 1 SMART SAFE CASH WRAP SENTINAL SCD-XL & TUBE 24.25" x 24" x 40" O V NO CONNECTIONS BEHIND ONLY MOUNT CONNECTIONS TO SIDE OF UNIT (NOT BEHIND) 33 1 ICE CREAM MERCHANDISER RETAIL ZERO ZONE O GC REMOTE CONDENSER ON ROOF #33A 33C 1 ICE MAKER ( OVER BEV. DISP.) DRINK WALL N13 22R-32 SCOTSMAN PRODIGY PLUS O GC SITS ABOVE #4 (ON SOFFIT ABOVE CONNECTED TO #18A-REMOTE CONDENSER)ALWAYS ON CUSTOMERS LEFT 42 4 POS ARRAY PER PLAN O O 46 1 CIGARETTE CASE CASH WRAP VENDOR O GC 48 1 CREAMER DISPENSER COFFEE COUNTER CREAMISER MODEL400 21"x16"x29" O V 51 4 STAINLESS STEEL SINK (HAND OR BAR) PER PLAN FURNISHED BY MILLWORK GC GC SEE PLUMBING DRAWINGS 72.1 2 FROZEN CARBONATED BEV. DRINK WALL ICEE-VIPER 4 FLAV. 23" x 32.5" x 37" (or 43.7") O GC INTERNAL CONDENSER 95 1 F'REAL DRINK WALL O GC/O 96 1 F'REAL DRINK WALL 11-CSGF-X1-FRRL O GC/O 97 2 SPEED OVEN DELI PREP AREA O GC 99 2 PIZZA OVEN DELI PREP O GC SEE ELECTRICAL PLAN 108 1 PREP TABLE DELI PREP AREA O GC 109 1 TORTILLA TABLE DELI PREP O GC 110 1 TEA BREWER COFFEE PREP RSTB / CURTIS 34.250" x 13.16" x 20.875" O GC 111 1 TORTILLA TOASTER DELI PREP AREA O GC 112 2 HAND DRYER MEN'S AND WOMEN'S RESTROOMS COLUMBIA VORTEX 9" x 12 43/64" x 7 3/32" O GC N9 6 COFFEE CUP DISPENSER COFFEE COUNTER BUNN - 39550 MAVERIK CUSTOM O GC N31 7 WIRE SHELVING ISS (VARIOUS SIZES, SHAPES) O GC N33 1 OVERHEAD WIRE SHELF WITH BRACKET 48"x 18"x 2" O GC CONFIRM WITH OWNER'S REP. N49 1 SNEEZE GUARD HOT DOG COUNTER MAVERIK CUSTOM O GC PLACED ABOVE EQUIPMENT NUMBER 13 OR 13.2 N50 2 BABY CHANGING STATION MEN'S AND WOMEN'S RESTROOMS O GC N62 5 COAT HOOK MEN'S AND WOMEN'S RESTROOMS BOBRICK B-233 GC GC MOUNTED 46" AFF N63A 5 PAPER TOWEL DISPENSER RESTROOMS CORMATIC AUTO TOWEL DISP. 14.25" x 9.1" x 15.5" O GC N63D 6 GRAB BAR RESTROOMS BOBRICK B-6806 18", 36" OR 42" GC GC N65 3 SANITARY NAPKIN DISPOSAL WOMEN'S RESTROOMS O GC N66 5 TOILET PAPER DISPENSER MEN'S AND WOMEN'S RESTROOMS O GC N67 4 UNDER COUNTER BAG RACK CASH WRAP COUNTER OWNER CUSTOM O GC N69 6 UNDERCOUNTER CANDY RACKS SHOP CO 2" x 12" x 2" O GC N71 2 STAINLESS STEEL TRASH CHUTE HOT DOG COUNTER OWNER CUSTOM GC GC N95 4 SNEEZE GUARD DELI SERVICES GC GC N101 1 4' TABLE COFFEE PREP ISS (VARIOUS SIZES, SHAPES) O GC CONFIRM WITH OWNER'S REP. N102 2 TEA BREWER CONTAINER DRINK WALL O GC N105 1 WIRE SHELF DELI PREP N106 1 CONDIMENT RACK HOT DOG COUNTER N109 1 LABEL MAKER DELI PREP N110 2 FLAVOR SHOT RACK COFFEE COUNTER PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY: APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSIO N OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.10/8/2020 11:28:52 AMEQUIPMENT SCHEDULE 2020020.47 FINAL DRAWINGS 07/10/20 PR AC TYPE B REMODEL A1.04MAVERIK, INC.3202 W. USTICK RD.MERIDIAN, ID 83646MAVERIK C-STORE #405GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 10/09/20 H H 33 2 2 1 1 E E D D C C A A 103 MEN'S 109 OFFICE 104 EXIT HALLWAY 102 WOMEN'S 105 DELI PREP 106 KITCHEN SERVICE 110 30° BEER COOLER 111 35° BEVERAGE COOLER 101 RETAIL 112 STORAGE 108 -10° FREEZER 107 35° STOR COOLER 10.46 09.59 B B F F 2.1 2.1 2.2 2.2 113 ELECTRICAL ROOM TYP. 26.04 09.47 05.02 10.54 10.45 12 A5.11 09.60 09.60 09.60 3' - 0"10' - 6 3/8" BELOW 02.83 02.83 G G 09.60 115 STORAGE P-7 P-7 P-7 09.36 09.36 09.36 ACT-1 09.01 09.61 02.83 02.83 02.83 P-7 02.83 10.45 02.83 02.83 09.71 09.71 2x4 LAY-IN LIGHT FIXTURE; SEE ELECTRICAL 2x4 FIXTURE, EMERGENCY LIGHT; SEE ELECTRICAL LINEAR LIGHT FIXTURE, SEE ELECTRICAL RECESSED LIGHT FIXTURE WALL SCONCE: SEE ELECTRICAL 4'-0" SURFACE MOUNTED LIGHT FIXTURE COOLER VAPOR PROOF LIGHT; SEE ELECTRICAL SCHEDULE EXIT LIGHTING SUPPLY AND RETURN AIR VENTS SKYLIGHT; SEE ROOF PLAN 4'-0" SURFACE MOUNTED EMERGENCY LIGHT FIXTURE 4'-0" SURFACE MOUNTED LIGHT FIXTURE SCALE:1/4" = 1'-0"1 REFLECTED CEILING PLAN 09.71 PROVIDE NEW HEADER AT NEW DOOR LOCATION 10.45 43" MENU MONITORS, (BY OWNER) AND CEILING MOUNTED BRACKET; SEE DETAILS 8 & 9 ON SHEET A5.11 10.46 75" MONITOR, (PROVIDED BY OWNER) AND CEILING MOUNTED BRACKET; SEE DETAILS 10 & 11 ON SHEET A5.11 10.54 MONITOR, (BY OWNER) IN FOUNTAIN MACHINE 26.04 NEW LIGHT FIXTURE, SEE ELECTRICAL PLANS 02.83 NO CEILING WORK IN THIS AREA 05.02 METAL SOFFIT PANEL, COLOR C-2 BRITE RED. PROVIDE STRAPPING AS REQUIRED 09.01 SCHEDULED CEILING, INSTALL SUSPENDED CEILING BRACING SEE DETAIL 6/A5.11 09.36 PAINT EXISTING CEILING. SEE SCHEDULE ON SHEET A6.03 09.47 HEADER, PAINT P-7, SEE SCHEDULE ON SHEET A6.03 09.59 PAINT EXISTING OPEN CEILING (STRUCTURE, DECK, DUCTWORK). SEE SCHEDULE ON SHEET A6.03 09.60 REPAINT ANY AND ALL LIGHTS THAT HAVE PREVIOUSLY BEEN PAINTED TO MATCH CEILING. SEE SCHEDULE ON SHEET A6.03 FOR NEW PAINT COLOR 09.61 SEE DETAIL 5/A5.11 FOR SUSPENDED CEILING TILE AT WALL KEYED NOTES SYMBOLS (EXISTING, U.N.O.) PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY: APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSIO N OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.10/8/2020 11:28:55 AMREFLECTED CEILING PLAN 2020020.47 FINAL DRAWINGS 07/10/20 PR AC TYPE B REMODEL A1.05MAVERIK, INC.3202 W. USTICK RD.MERIDIAN, ID 83646MAVERIK C-STORE #405N GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 10/09/20 05.67 09.1310.45 09.20 10.11 09.35 10.11 OPEN BEYOND 10.45 06.07 09.5810.46 06.07 10.54 09.13 09.13 09.20 09.58 09.58 10.11 TYP. 09.16 10.11 09.20 26.09 PLAN VIEW 8 3 8 WALL TYPE STUD SIZE 3 5/8"5/8"5/8"D3 WALL WIDTH 4 7/8"StudSize1 5 TYP 2 SECTION VIEWTYP6" MIN.WALL WIDTH VARIES WITH STUD SIZE 3 9 88 Type - D Typical Metal Stud Wall 5 10 WALL TYPE STUD SIZE WALL WIDTH E3 3 5/8"4 7/8" 16 SECTION VIEW PLAN VIEW 6 178 14 6 17 18 13 12 1 1/2" 1 1/2"3" 3/16" 8 8 9" 13 14 Type - E Partial Height Wall WALL WIDTH VARIES WITH STUD SIZE 3/4" FOR WALL HEIGHTSEE FLOOR PLANAND INTERIOR ELEVATIONS10 3/4"2"3/4"4 4 3 PLAN VIEW 3 8 WALL TYPE STUD SIZE 3 5/8"5/8"C3 WALL WIDTH 4 1/4" 1 5 TYP 2 SECTION VIEWTYP6" MIN.WALL WIDTH VARIES WITH STUD SIZE 3 9 8 Type - C Typical Metal Stud Wall 5 4 4 6"D6 7 1/4"R.O.FIN. FLOOR DOOR FRAME BEYOND FIXED FLOOR ANCHOR IN JAMB BEYOND TILE FLOORING CONCRETE SLAB LEVEL, GROUTED TRANSITION BETWEEN TILES DOUBLE STUD ALL DOOR JAMBS (CONTINUE TO AND FASTEN TO JOIST OR UNISTRUT ABOVE VARIES COUNTER SUNK FLAT HEAD SCREWS 1/2"2" 5/8"R.O.PT. HARDWOOD SHIM AT PIN ASSEMBLY ATTACHMENT POINTS AS REQUIRED DOUBLE METAL FRAMING HEAD VARIES 1/2"2" 5/8"R.O.PT. HARDWOOD SHIM AT PIN ASSEMBLY ATTACHMENT POINTS AS REQUIRED STUD TRACK HEAVY GAUGE TRACK (18 GAUGE MINIMUM) DOOR FRAME SCALE:1/4" = 1'-0"1 RETAIL ELEVATION - RIGHT SCALE:1/4" = 1'-0"2 RETAIL ELEVATION - BACK WALL TYPE KEYED NOTES 05.67 STEEL AWNING, PAINTED TO MATCH BRITE RED, SEE DETAIL 12 ON SHEET A5.11 AND SCHEDULE ON SHEET A6.03 06.07 CASEWORK PROVIDED AND INSTALLED BY OWNER'S VENDOR 09.13 GYPSUM WALL BOARD WITH LEVEL 3 FINISH FOR SUEDE WALL GRAPHICS, PAINTED P-1 09.16 PLASTIC LAMINATE CABINET, SEE SCHEDULE ON SHEET A6.03 09.20 RUBBER BASE, SEE SCHEDULE ON SHEET A6.03 09.35 SOLID SURFACE COUNTERTOP, SEE DETAIL ON 14/A4.02 AND SEE SCHEDULE ON SHEET A6.03 09.58 HATCHED WALL INDICATES NEW WALL TO RECEIVE NEW PAINT / GRAPHICS AS INDICATED 10.11 SS CORNER GUARD, SEE SHEET A1.02 FOR LOCATIONS 10.45 43" MENU MONITORS, (BY OWNER) AND CEILING MOUNTED BRACKET; SEE DETAILS 8 & 9 ON SHEET A5.11 10.46 75" MONITOR, (PROVIDED BY OWNER) AND CEILING MOUNTED BRACKET; SEE DETAILS 10 & 11 ON SHEET A5.11 10.54 MONITOR, (BY OWNER) IN FOUNTAIN MACHINE 26.09 MICROPHONE, SEE ELECTRICAL PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY: APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSIO N OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.10/8/2020 11:29:00 AMINTERIOR ELEVATIONS & WALL TYPES 2020020.47 FINAL DRAWINGS 07/10/20 PR AC TYPE B REMODEL A2.51MAVERIK, INC.3202 W. USTICK RD.MERIDIAN, ID 83646MAVERIK C-STORE #4051. LINE OF ROOF DECK AS OCCURS. 2. TO ACCOMMODATE FOR STRUCTURE DEFLECTION, PROVIDE SLIP CONNECTION BETWEEN TOP RUNNER TRACK AND METAL STUD FRAMING. 3. METAL STUDS, 20 GA STRUCTURAL (33 MILS) AT 16" O.C, U.N.O. BASED ON WALL TYPES INDICATED IN FLOOR PLAN, PROVIDE STUD SIZE AS INDICATED IN WALL TYPES WITH TRACK RUNNERS AT TOP AND BOTTOM. FOR STUD FRAMING AROUND DOOR AND WINDOW OPENINGS. 4. EXTEND GYPSUM BOARD TO ROOF DECK IN PUBLIC AREAS WHERE THERE IS NO CEILING. CUT GYPSUM BOARD TO FILL FLUTES OF ROOF DECK, WHERE APPLICABLE. 5. LINE OF CEILING AS OCCURS SEE REFLECTED CEILING PLAN. 6. 3/8" THICK STEEL PLATE WITH 4-1/2" DIA. HILTI-HY200 EPOXY ANCHORS WITH 2-3/8" HILTI-HIT -Z ANCHORS. EMBED INTO CONCRETE 2-3/8" 7. NOT USED. 8. GYPSUM BOARD, 5/8" THICK, U.N.O, ATTACHED TO METAL STUD FRAMING. SEE GENERAL NOTE 'B'. 9. ANCHOR BASE TRACK TO CONCRETE FLOOR BELOW. 10. LINE OF FLOOR. 11. NOT USED. 12. METAL STUDS 16GA STRUCTURAL (35 MIL) AT 16" O.C. PROVIDE RUNNERS AT TOP AND BOTTOM. ATTACH TOP RUNNER TO PLYWOOD AND VERTICAL STEEL POST. 13. PROVIDE 1/4" RADIUS ROUNDED EDGE, CONTINOUS. 14. STOP STUD RUNNER AT BASE PLATES. 15. NOT USED. 16. WALL CAP. SOLID SURFACE MATERIAL ATTACHED TO WALL BELOW. 17. TUBE STEEL 3" x 3" x 3/16" AT 6'- 0" O.C. INTERIOR ELEVATIONS KEYED NOTES GENERAL NOTES A. CONTRACTOR SHALL VERIFY ITEMS LIKE SEMI OR FULLY RECESSED MISCELLANEOUS BOXES, PANELS, PLUMBING LINES, CONDUITS, PIPES, ETC. THAT ARE CONCEALED IN THE WALL. IF 3-5/8" METAL STUD ARE INADEQUATE, CONTRACTOR SHALL NOTIFY THAT ARCHITECT AND USE 6" STUDS. COORDINATE WITH ALL THE CONSULTANT DRAWINGS PRIOR TO WALL CONSTRUCTION AND USE 6" OR 8", 20 GAUGE METAL STUDS FOR FRAMING IN LIEU OF 3-5/8" METAL STUDS. B. USE 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD IF CERAMIC OR PORCELAIN WALL TILES ARE INDICATED IN THE FINISH SCHEDULES AS WALL FINISH. MOISTURE RESISTANT GYPSUM WALL BOARD SHALL EXTEND FROM FINISHED FLOOR TO HEIGHT OF TILE. 5/8" WATER RESISTANT GYPSUM BOARD TO BE USED ABOVE TILE HEIGHT IN RESTROOMS. C. PROVIDE CONTROL JOINT WHEN LENGTH OF GYPSUM BOARD EXCEEDS 50' IN ONE DIRECTION OR AS DIRECTED BY ARCHITECT. COORDINATE WITH ARCHITECT FOR CONTROL JOINT LOCATIONS. WHEN GYPSUM BOARD IS ATTACHED VERTICALLY, USE 1" LONG #6 DRYWALL SCREWS TO EACH STUD. SCREWS ARE 8" O.C. AT PERIMETER AND 12" AT INTERMEDIATE STUD. WHEN GYPSUM BOARD IS ATTACHED HORIZONTALLY TO STUDS, HORIZONTAL JOINTS SHALL BE STAGGERED WITH THOSE ON THE OPPOSITE SIDE. SCREWS FOR HORIZONTAL APPLICATION SHALL BE 8" O.C. AT VERTICAL EDGES AND 12" O.C. AT INTERMEDIATE STUDS. D. SEE DIMENSION FLOOR PLAN FOR WALL TYPES USED IN THIS PROJECT. GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 DOOR SCHEDULE DOOR NUMBE R ROOM DOORS FRAME HARDWARE GROUP COMMENTSWIDTH HEIGHT TYPE MATERIAL FINISH TYPE MATERIAL HEAD JAMB SILL 101 RETAIL 3' - 0" 7' - 0" ULTRA LITE SS STAINLESS STEEL STAINLESS STEEL ULTRA LITE SS WELDED HM 5/A2.51 4/A2.51 3/A2.51 BY MANUF PROVIDE SPRING GUARD, VISION PAINE, AND RUBBAIR DOOR STOP 102 WOMEN'S 3' - 0" 7' - 0" - - - - WELDED HM 5/A2.51 4/A2.51 3/A2.51 - IN EX. OPNG. 103 MEN'S 3' - 0" 7' - 0" - - - - WELDED HM 5/A2.51 4/A2.51 3/A2.51 - IN EX. OPNG. SCALE:1 1/2" = 1'-0"3 DOOR SILL - INTERIOR SCALE:1 1/2" = 1'-0"4 DOOR JAMB - INTERIOR SCALE:1 1/2" = 1'-0"5 DOOR HEAD - INTERIOR 10/09/20 103 MEN'S 104 EXIT HALLWAY 102 WOMEN'S 4' - 0" 10.05 10.47 A4.01 5 6 2 3 2' - 4"A4.01 7 8 9 10 A4.01 4 10.44 10.29 10.28 10.1410.14 10.144' - 0"CLEAR 4' - 10 5/8" 10.05 10.47 10.44 10.28 10.1410.14 10.14 1' - 10"1' - 10"22.06 6' - 4" 09.69 09.69 10.13 CLEAR 4' - 6 5/8" 10.13 22.06 CLEAR2' - 6"1' - 3"3' - 0" CLEAR 2' - 6" CLEAR 2' - 6" CLEAR 2' - 8" 2' - 7"2' - 8"6' - 3 7/8"V.I.F.8' - 2 7/8"3' - 6"4' - 7 7/8"2' - 8"2' - 0"2' - 6" 10.28 10.44 11.12 2' - 8"3' - 0" CLEAR 2' - 6" CLEAR 2' - 9" CLEAR 2' - 9" 11.12 10.29 10.28 10.44 2' - 8 1/2"2' - 10"6' - 0 3/8"4' - 8 1/2"3' - 6"V.I.F.8' - 3 3/4"3' - 0" MIN11.13 11.13 10.29 10.28 10.44 TYP. 10.29 TYP. 10.28 6"36" 09.13 10.1410.14 7' - 2"09.2509.2509.2509.70 2' - 10"11.13 11.12 09.02 OPEN 7" - 9" 12" MAX.42"40"18" MIN.40"10.1410.14 10.2910.287' - 2"10.13 3' - 7" 18"09.13 09.02 10.05 09.13 09.02 3' - 5 1/4"7' - 2"09.25 10.13 10.05 10.47 09.02 3' - 6"09.13 09.70 09.25 1/4" CLEAR 4' - 8 1/2"1" 10.28 10.29 09.25 1' - 0"09.25 10.05 09.02 09.13 7' - 2"3' - 5 1/4"10.13 11.12 42"12" 40"40"18" MIN.7" - 9" 10.1410.14 10.28 09.02 09.13 7' - 2"3' - 7"10.13 34"18"3' - 0"6" 10.1410.14 TYP. 10.28 09.13 34"7' - 2"09.02 09.2509.2509.25 09.70 OPEN 10.47 09.02 09.70 09.13 11.13 11.12 PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY: APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSIO N OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.10/8/2020 11:29:10 AMENLARGED RESTROOM PLAN AND ELEVATIONS 2020020.47 FINAL DRAWINGS 07/10/20 Author Approver TYPE B REMODEL A4.01MAVERIK, INC.3202 W. USTICK RD.MERIDIAN, ID 83646MAVERIK C-STORE #405SCALE:1/2" = 1'-0"1 ENLARGED RESTROOM PLAN SCALE:1/4" = 1'-0"2 WOMEN'S ELEVATION SCALE:1/4" = 1'-0"3 WOMEN'S ELEVATION SCALE:1/4" = 1'-0"5 WOMEN'S ELEVATION SCALE:1/4" = 1'-0"6 WOMEN'S ELEVATION SCALE:1/4" = 1'-0"4 TOILET STALL ELEVATION - NON ADA KEYED NOTES 09.02 WALL TILE, SEE SCHEDULE ON SHEET A6.03 09.13 GYPSUM WALL BOARD WITH LEVEL 3 FINISH FOR SUEDE WALL GRAPHICS, PAINTED P-1 09.25 TOILET PARTITION, SEE SCHEDULE. ALL PANELS TO BE 58" TALL, MOUNT TO FLOOR/CEILING/WALL, PROVIDE BLOCKING AS REQUIRED. PARTITIONS ADJACENT TO THE URINAL TO BE MOUNTED WITH TOP AT 60" A.F.F. MINIMUM 09.69 NEW FRAME TO BE PAINTED BLACK FOX, SW #7020 09.70 TOILET PARTITION, SEE SCHEDULE. END PANELS TO BE 70" TALL MOUNTED AT 0'-0" AFF, MOUNT TO FLOOR/CEILING/WALL, PROVIDE BLOCKING AS REQUIRED 10.05 ELECTRIC HAND DRYER. SEE EQUIPMENT PLAN & SCHEDULE 10.13 BABY CHANGING STATION, SURFACE MOUNT, PROVIDE BLOCKING AS REQUIRED 10.14 GRAB BARS, BLOCK AS REQUIRED 10.28 TOILET PAPER DISPENSER 10.29 SANITARY NAPKIN DISPOSAL 10.44 COAT HOOK 10.47 PAPER TOWEL DISPENSER, BY OWNER 11.12 SOAP DISPENSER 11.13 MIRROR 22.06 SINK, SEE PLUMBING DRAWINGS GENERAL NOTES 1. CAULKING AROUND FLOOR SINKS, TOILETS, URINALS, MOP SINKS, ETC. SHALL BE WHITE SILICON - BASE PLUMBING CAULK. 2. GENERAL CONTRACTOR RESPONSIBLE FOR WOOD BLOCKING FOR ALL PARTITIONS, GRAB BARS, MIRRORS, EQUIPMENT (PAPER TOWEL DISPENSER, SOAP, ETC.) AND PLUMBING FIXTURES. 3. SEE REFLECTED CEILING PLAN FOR CEILING HEIGHTS. 4. EQUIPMENT TO BE PROVIDED BY OWNER AND RECEIVED, STORED AND INSTALLED BY CONTRACTOR. 5. SEE EQUIPMENT PLAN AND SCHEDULE FOR SPECIFICATIONS. SCALE:1/4" = 1'-0"7 MEN'S ELEVATION SCALE:1/4" = 1'-0"8 MEN'S ELEVATION SCALE:1/4" = 1'-0"9 MEN'S ELEVATION SCALE:1/4" = 1'-0"10 MEN'S ELEVATION GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 10/09/20 2"1/2"1/2"1/2"1"1/2"3/4" 09.35 06.24 09.16 09.44 1 3/4"1"1/2"09.35 06.24 09.44 1/2" A4.02 A4.02 A4.02 2 2' - 10 1/8"1' - 11 1/4"8' - 7"1' - 11 1/4"2' - 7 1/2"2' - 3 3/8"3' - 6 7/8"1' - 4 1/2"3' - 5 3/4"3' - 6 7/8"10' - 10 1/2"3' - 5 3/4" 17' - 11 1/8"5' - 10 1/4"4' - 10 1/4"1' - 11 1/4"1' - 0"1' - 11 1/4"3 5 A4.02 4 11.09 TYP. 11.05 09.48 14 A4.02 26.09 2' - 7 1/2"ANGLED 2' - 1 1/2"1' - 0 7/8"2' - 2 3/4"1' - 0 7/8"2' - 1 1/2"ANGLED 2' - 7 1/4" 17' - 8 5/8" 11.1111.09 09.48 09.20 09.16 2' - 10"CASH DRAWERCASH DRAWER CASH DRAWER CASH DRAWER ANGLED ANGLED 4' - 6 3/8"2' - 10"11.05 09.48 09.16 09.20 2' - 1 1/2"ANGLED 5' - 7 3/8" 09.16 09.48 09.20 6"2' - 2 1/2"1 1/2"2' - 10"11.05 ANGLED6"4' - 1 1/2"1' - 7"4' - 1 1/2"6"ANGLED 17' - 8 5/8"2' - 10"11.05 11.0511.0511.05 09.48 09.16 09.20 11.0511.05 11.0511.05 11.0511.05 19' - 4"3' - 0"A4.02 7 10.47 09.35 15 A4.02 TYP. 2"1' - 8"1' - 8"1' - 8"1' - 11"1' - 8"1' - 8"1' - 8"1' - 8"1' - 9 1/2"1' - 9 1/2"1' - 10"2" 19' - 4" 09.35 09.16 09.20 TYP. 09.224"2"2' - 2"6"2' - 10"TRASH A4.0211 A4.02 12 6" 2' - 6"1' - 9"6' - 2 3/8"2' - 11"7' - 1 5/8"3' - 0"2' - 11" TRASH 09.24 09.24 09.20 09.20 1 1/2"2' - 2 1/2"6"2' - 10"09.16 09.35 TYP. 11.10 7' - 1 5/8"2' - 11"6' - 2 3/8" 09.3509.35 09.16 09.2009.20 09.16 09.63 09.37 4"1' - 8"6"1' - 2 5/8"1' - 1 7/8"1 1/2"3' - 7"1 1/2"1' - 0"3' - 8 1/2"09.20 09.16 09.3509.35 TYP. 11.10 16' - 2 7/8"4"1 1/2"2' - 2 1/2"6"2' - 10"2 3/4" 2' - 10 1/2" 2 3/4" 3' - 4" 09.63 09.16 09.20 A4.02 8 10.47 2' - 2"3' - 6" KEYED NOTES 06.24 PLYWOOD BACKING, BY COUNTERTOP FABRICATOR 09.16 PLASTIC LAMINATE CABINET, SEE SCHEDULE ON SHEET A6.03 09.20 RUBBER BASE, SEE SCHEDULE ON SHEET A6.03 09.22 PLASTIC LAMINATE PANEL, SEE SCHEDULE ON SHEET A6.03 09.24 FIBERGLASS REINFORCED PANEL (FRP-1), SEE SCHEDULE ON SHEET A6.03 09.35 SOLID SURFACE COUNTERTOP, SEE DETAIL ON 14/A4.02 AND SEE SCHEDULE ON SHEET A6.03 09.37 P-LAM ADJUSTABLE SHELF, SEE SCHEDULE ON SHEET A6.03 09.44 SOLID SURFACE EDGE (SS-1) WITH 1/8" FILLET ON TOP EDGES 09.48 SOLID SURFACE COUNTERTOP, SEE DETAIL ON 13/A4.02 AND SEE SCHEDULE ON SHEET A6.03 09.63 STAINLESS STEEL COUNTERTOP 10.47 PAPER TOWEL DISPENSER, BY OWNER 11.05 OWNER PROVIDED EQUIPMENT 11.09 SAFE #23, COORDINATE STUB UP TO BE NEXT TO EQUIPMENT (NOT BEHIND) SEE ELECTRICAL 11.10 SNEEZE GUARD, PROVIDED AND INSTALLED BY MILLWORK VENDOR 11.11 UNDERCOUNTER BAG DISPENSER PROVIDED BY OWNER, INSTALLED BY CONTRACTOR 26.09 MICROPHONE, SEE ELECTRICAL SCALE:6" = 1'-0"14 COUNTERTOP EDGE DETAIL PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY: APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSIO N OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.10/8/2020 11:29:15 AMENLARGED RETAIL PLANS & ELEVATIONS 2020020.47 FINAL DRAWINGS 07/10/20 PR AC TYPE B REMODEL A4.02MAVERIK, INC.3202 W. USTICK RD.MERIDIAN, ID 83646MAVERIK C-STORE #405SCALE:6" = 1'-0"15 SOLID SURFACE COUNTERTOP DETAIL GENERAL NOTES 1. ALL MILLWORK AT WET LOCATIONS TO BE CONSTRUCTED WITH STYLELITE PANELS (BOTTOM OF GARBAGE, BOTTOM OF CABINETS WITH PENETRATIONS, SINK CABINETS). SCALE:1/2" = 1'-0"1 CASH WRAP COUNTER PLAN SCALE:1/2" = 1'-0"2 CASH WRAP ELEVATION SCALE:1/2" = 1'-0"5 CASH WRAP ELEVATION SCALE:1/2" = 1'-0"3 CASH WRAP ELEVATION SCALE:1/2" = 1'-0"4 CASH WRAP ELEVATION SCALE:1/2" = 1'-0"6 DRINK WALL COUNTER PLAN SCALE:1/2" = 1'-0"7 DRINK WALL ELEVATION SCALE:1/2" = 1'-0"10 DELI COUNTER PLAN SCALE:1/2" = 1'-0"11 DELI ELEVATION SCALE:1/2" = 1'-0"12 DELI ELEVATION SCALE:1/2" = 1'-0"8 SINK ELEVATION SCALE:1/2" = 1'-0"9 KITCHEN SERVICE SINK PLAN GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 10/09/20 4 ' - 9 3 /8 "5' - 1 1/4"A4.03 16 A4.03 17 A4.03 18 09.48 TYP. 11.05 11.05 09.22 2' - 4 3/4"5"2' - 3"2"2' - 2"2' - 10"09.20 09.16 09.48 09.22 1' - 6 1/8"1' - 7 1/8"1' - 6 1/8" 4' - 7 3/8" TRASH2"2' - 3"5"2' - 10"09.20 09.16 09.48 09.22 5' - 1"5"2' - 3"2"2' - 10"09.20 09.16 09.48 09.22 1' - 6 1/8"1' - 7 1/8"1' - 6 1/8" 4' - 7 3/8" 1 ' - 6 " 8 ' - 1 1 " 1 ' - 6 " 1 1 ' - 1 1 "1' - 6"2' - 6"1' - 6"5' - 6"09.48 TYP. 11.05 A4.03 4 A4.03 5 A4.03 A4.03 7 8 A4.03 11 A4.03 A4.03 12 13 4' - 0"7' - 0"EQEQ5' - 0" 09.22 11.05 09.48 A4.03 2 A4.03 3 11.05 TYP. 11.05 TYP. 11.05 10.47 2' - 6"13' - 6"11.05 TRASH 6"2' - 2"6"2' - 2"2"4"2' - 10"1"1' - 6"1' - 8"1' - 8"1' - 8"1' - 9"1' - 8"1' - 8"1' - 9"1" 13' - 6" 09.35 10.47 09.206"2' - 4"4"10.47 09.20 09.35 09.16 2' - 5" 1' - 5 1/2"1' - 5 1/2"1' - 6 1/4"1' - 3"2' - 8 1/2"5"ANGLED1 1/2"2' - 2 1/2"6"2' - 10"09.2309.23 09.48 09.16 09.20 6"2' - 2 1/2"1 1/2"2' - 10"2' - 4 3/4" 09.48 09.16 09.20 11.05 09.23 ANGLED ANGLED 5' - 3" 8' - 9 3/4"6"2' - 2 1/2"1 1/2"2' - 10"09.16 09.48 09.20 11.05 ANGLED 11' - 8" ANGLED2' - 4 3/4" 11.05 6"2' - 2 1/2"1 1/2"2' - 10"ANGLED ANGLED 5' - 3" 09.48 09.16 09.20 09.23 6' - 10" 1' - 4"1' - 4"1' - 6"1' - 4"1' - 4"5"2' - 3"2"2' - 10"09.22 09.48 09.16 09.202' - 2"2"2' - 3"5"2' - 10"1' - 4"1' - 4"1' - 6"1' - 4"1' - 4" 6' - 10" 09.48 09.16 09.20 09.22 3' - 10"5"2' - 3"2"2' - 10"09.22 09.48 09.16 09.20 A4.0314 09.35 V.I.F. 2' - 7"V.I.F.6' - 7 5/8"02.87 09.35 KEYED NOTES 02.87 EXISTING MILLWORK TO REMAIN 09.16 PLASTIC LAMINATE CABINET, SEE SCHEDULE ON SHEET A6.03 09.20 RUBBER BASE, SEE SCHEDULE ON SHEET A6.03 09.22 PLASTIC LAMINATE PANEL, SEE SCHEDULE ON SHEET A6.03 09.23 PLASTIC LAMINATE FINISH CAP, SEE SCHEDULE ON SHEET A6.03 09.35 SOLID SURFACE COUNTERTOP, SEE DETAIL ON 14/A4.02 AND SEE SCHEDULE ON SHEET A6.03 09.48 SOLID SURFACE COUNTERTOP, SEE DETAIL ON 13/A4.02 AND SEE SCHEDULE ON SHEET A6.03 10.47 PAPER TOWEL DISPENSER, BY OWNER 11.05 OWNER PROVIDED EQUIPMENT PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY: APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSIO N OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.10/8/2020 11:29:20 AMENLARGED RETAIL PLANS & ELEVATIONS 2020020.47 FINAL DRAWINGS 07/10/20 PR AC TYPE B REMODEL A4.03MAVERIK, INC.3202 W. USTICK RD.MERIDIAN, ID 83646MAVERIK C-STORE #405GENERAL NOTES 1. ALL MILLWORK AT WET LOCATIONS TO BE CONSTRUCTED WITH STYLELITE PANELS (BOTTOM OF GARBAGE, BOTTOM OF CABINETS WITH PENETRATIONS, SINK CABINETS). SCALE:1/2" = 1'-0"15 WARMER ISLAND COUNTER PLAN SCALE:1/2" = 1'-0"16 WARMER ISLAND ELEVATION SCALE:1/2" = 1'-0"17 WARMER ISLAND ELEVATION SCALE:1/2" = 1'-0"18 WARMER ISLAND ELEVATION SCALE:1/2" = 1'-0"6 HOT DOG ISLAND COUNTER PLAN SCALE:1/2" = 1'-0"10 COFFEE ISLAND COUNTER PLAN SCALE:1/2" = 1'-0"1 COFFEE WALL COUNTER PLAN SCALE:1/2" = 1'-0"2 COFFEE WALL ELEVATION SCALE:1/2" = 1'-0"3 COFFEE WALL ELEVATION SCALE:1/2" = 1'-0"4 HOT DOG ISLAND ELEVATION SCALE:1/2" = 1'-0"5 HOT DOG ISLAND ELEVATION SCALE:1/2" = 1'-0"7 HOT DOG ISLAND ELEVATION SCALE:1/2" = 1'-0"8 HOT DOG ISLAND ELEVATION SCALE:1/2" = 1'-0"11 COFFEE ISLAND ELEVATION SCALE:1/2" = 1'-0"12 COFFEE ISLAND ELEVATION SCALE:1/2" = 1'-0"13 COFFEE ISLAND ELEVATION SCALE:1/2" = 1'-0"9 OFFICE COUNTER PLAN SCALE:1/2" = 1'-0"14 OFFICE COUNTER ELEVATION TRASH GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 10/09/20 STAINLESS STEEL CORNER GUARD CAULK AT DISSIMILAR MATERIALS (TYP.) 2" MIN.3"1/4" TO 1/2" SPACE CEILING SUSPENSION GRID WALL ANGLE; FASTEN TO WALL FINISHED WALL METAL 2X4 CEILING SUSPENSION SYSTEM. WITH VINYL COATED PANELS 3" MIN. 8" MAX. HANGER WIRE. 12'-0" TYP.1 2 '-0 " T Y P .6 '-0 " M A X .CRO SS RUN N ERSMAIN RUNNERS WALL ANGLE 8" MAX. CEILING AREAS OF 144 SQ. FT. OR LESS SURROUNDED BY WALLS WHICH CONNECT DIRECTLY TO THE STRUCTURE ABOVE SHALL NOT REQUIRE THE DIAGONAL BRACING WIRES. EACH VERTICAL WIRE SHALL BE ATTACHED EACH END WITH MIN. 3 TURNS. CEILING GRID SHALL BE INSTALLED LEVEL TO WITHIN 1/8 " IN 12'. ALL WIRE LOOPS SHALL BE TIGHTLY WRAPPED AND SHARPLY BENT. FOR CEILING AREAS EXCEEDING 1,000 S.F. HORIZONTAL R ESTRAINT OF THE CEILING TO THE STRUCTURE SHALL BE PROVIDED. CABLE TRAYS AND ELECTRICAL CONDUITS SHALL BE SUPPOR TED AND BRACED INDEPENDENTLY OF THE CEILING. SUSPENDED CEILING SHALL BE SUBJECT TO THE SPECIAL INSPECTION REQUIREMENTS OF SECTION 1704. CEILING AREAS OF 1000 SQ. FT. OR LESS SURROUNDED BY WALLS WHICH CONNECT DIRECTLY TO THE STRUCTURE ABOVE SHALL NOT REQUIRE THE DIAGONAL BRACING WIRES. LOCAL KINKS OR BENDS SHALL NOT BE MADE IN HANGER WIRES AS A MEANS OF LEVELING MAIN RUNNERS. A HEAVY DUTY T-BAR SYSTEM SHALL BE USED. THE WIDTH OF THE PERIMETER SUPPORTING CLOSURE ANGLE SHALL NOT BE LESS THAN 2 INCHES. IN EACH ORTHOGONAL HORIZONTAL DIRECTION, ONE END OF THE CEILING GRID SHALL BE ATTACHED TO THE CLOSURE ANGLE . THE OTHER END IN EACH HORIZONTAL DIRECTION SHALL HAVE A 0.75 INCH CLEARANCE FROM THE WALL AND SHALL REST UPON AN D BE FREE TO SLIDE ON THE CLOSURE ANGLE. A5.11 7 VERTICAL WIRES - 12 GA. 2" M AX. 2" M AX. MAIN RUNNERCROSS R U N N E R PROVIDE VERTICAL STRUT OF CONTINUOUS LENGTH OF CEILING GRID MATERIAL OR OTHER APPROVED LIGHT METAL FRAMING MATERIAL ATTACHED TO MAIN RUNNER AND TO STRUCTURE ABOVE TO COUNTERACT UPLIFTING FORCES OF SPLAYED WIRES.SPLAY WIRES - 12 G.A. @ 12'-0" O.C. IN PLANE OF EACH RUNNER. TIE BOTH ENDS W/ MIN. 3 TURNS IN 1" OF RUN TYPICAL. ALL CEILING MOUNTED LIGHT FIXTURES SHALL BE ATTACHED TO SUSPENDED CEILING GRID, IN ADDITION 12 GA. HANGER WIRES SHALL BE ATTACHED TO THE GRID WITHIN 3" OF EACH CORNER OF THE FIXTURE. TWO ADDITIONAL WIRES SHALL BE CONNECTED TO THE LIGHT HOUSING AND TO THE STRUCTURE ABOVE (THESE WIRES MAY BE SLACK). WIRES SHALL NOT ATTACH TO OR BEND AROUND INTERFERING MATERIAL OR EQUIPMENT, NOR SHALL THEY BE CLOSER THAN 5" FROM ANY UN-BRACED HORIZONTAL PIPING OR DUCTWORK. A TRAPEZE OR SIMILAR DEVICE SHALL BE USED WHERE OBSTRUCTIONS OCCUR. VERTICAL WIRES 12 GA. @ 4'-0" O.C. FASTEN WIRES TO BOTTOM OF TRUSS CORD WITH HILTI EYE LAG CEILING HANGER - 1/4" EL WS. OR APPROVED EQUAL. 4 5 ° M A X .45° MAX.45° MAX.45° M AX.3/4"MINUS 1/4"CLEAR LENGTHMINUS 1/4" CLEAR LENGTH 3/4" PLAN A 9"3/4"3"SECTION B SECTION C NOTE: ALL FLOOR SINKS SHALL BE SEALED WITH WHITE PLUMBERS CAULK AS REQUIRED. 3/4" 22.0822.08 NOTE: GOES IN BASE CABINET WITH FLOOR SINK (5 LOCATIONS). 7' - 9"05.41 10.26 05.35 7' - 9"1' - 1 1/2"4' - 5 3/8" 7 7/8"7 7/8"10.2310.23 3' - 3"8' - 6"05.41 10.18 05.35 8' - 6"2' - 0"2' - 6" 1' - 3 3/4"1' - 3 3/4"10.18 EXISTING DROP PARTITION. NEW WALL GRAPHIC, SEE SHEET A2.51 COORDINATE ATTACHMENT WITH STRUCTURAL SIGN, OWNER FURNISHED, CONTRACTOR INSTALLED STEEL AWNING PAINTED TO MATCH BRITE RED, SEE DETAIL 4 ON SHEET S5.10 AND SCHEDULE ON SHEET A6.03 METAL SOFFIT PANE, COLOR: C -2 GYPSUM BOARD SOFFIT, PAINTED P-7 9' - 0"1 3/4"1 3/4"1 3/4"A PLAN BASE OF CABINET FIELD VERIFY 1 3/4" B SECTION 07.19 07.18 6"3 1/2"FIELD VERIFY05.29 MECHANICAL EQUIPMENT -SEE MECHANICAL DRAWINGS SEE MECHANICAL FOR EQUIPMENT ATTACHMENT ROOFING TERMINATION BAR WITH APPROVED FASTENERS @ 6" O.C. TYP. EQUIPMENT CURB WITH PT. WOOD NAILER AT TOP OF CURB MEMBRANE FLASHING COMPATIBLE WITH EXISTING ROOF MEMBRANE PROVIDE CONTINUOUS SEALANT AT INTERSECTION OF WOOD BLOCKING TO CURB. -TYP. CONT. SEALANT TAPE AT TOP OF CURB -TYP. SEALANT, TYP. CONT. STEEL CHANNEL, SEE STRUCTURAL EXISTING ROOF MEMBRANE, PROTECT DURING CONSTRUCTION SEE STRUCTURAL CURB ATTACHMENT PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY: APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSIO N OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.10/8/2020 11:29:23 AMDETAILS 2020020.47 FINAL DRAWINGS 07/10/20 PR AC TYPE B REMODEL A5.11MAVERIK, INC.3202 W. USTICK RD.MERIDIAN, ID 83646MAVERIK C-STORE #405SCALE:1/4" = 1'-0"1 CORNER GUARD DETAIL SCALE:1 1/2" = 1'-0"5 ACOUST. TILE/WALL SCALE:1/8" = 1'-0"6 SUSPENDED CEILING BRACING SCALE:3/8" = 1'-0"7 SEISMIC BRACING SCALE:1 1/2" = 1'-0"4 STAINLESS STEEL SINK SURROUND SCALE:1/2" = 1'-0"8 FOOD AREA TV-SIDE VIEW SCALE:1/2" = 1'-0"9 FOOD AREA TV-FRONT VIEW SCALE:1/2" = 1'-0"10 CASHWRAP TV-SIDE VIEW SCALE:1/2" = 1'-0"11 CASHWRAP TV-FRONT VIEW SCALE:1/2" = 1'-0"12 BONFIRE CANOPY SCALE:3" = 1'-0"2 STAINLESS STEEL PIPE APRON (PLATE) KEYED NOTES 10.23 10" WIDE ACCESS FOR CABLE MANAGEMENT 10.26 (2) 43" TV PROVIDED BY OWNER 22.08 18 GAUGE STAINLESS STEEL SINK #6 SATIN FINISH W/ 3/4" CONTINUOUS FLANGE AND 3/8" DIAMETER CROSS BAR. FIELD VERIFY DIMENSIONS PRIOR TO FABRICATION 05.29 1/8" THICK STAINLESS STEEL PLATE WITH #6 SATIN FINISH AND BEVELED EDGES 05.35 STEEL BRACKET, PAINTED BLACK, COORDINATE WITH STRUCTURAL 05.41 STEEL PIPE, COORDINATE WITH STRUCTURAL 07.18 BACKER ROD 07.19 SILICONE SEALANT, CONTINUOUS. SEE SCHEDULE FOR COLOR 09.10 STAINLESS STEEL CORNER GUARD 09.12 CAULK AT DISSIMILAR MATERIALS (TYP.) 10.18 75" TV PROVIDED BY OWNER SCALE:3" = 1'-0"13 MECH CURB DETAIL 3 NOT USED GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 10/09/20 INTERIOR FINISH SCHEDULE Number Name Floor Finish Base Finish Wall - BK Wall - FT Wall - L Wall - R Ceiling Finish Ceiling Height NOTES 101 RETAIL CT-4 RB-1 GWB (P-7) GWB (P-7) GWB (P-7) GWB (P-7) EXPOSED (P-7) ALL HEADERS/SOFFITS TO BE P-7 U.N.O. 102 WOMEN'S CT-4 - CT-1/G-1, GWB (P-7) CT-1/G-1, GWB (P-7) CT-1/G-1, GWB (P-7) CT-1/G-1, GWB (P-7) GWB (P-7) EXIST ACCESS PANELS TO MATCH ADJACENT MATERIAL COLOR 103 MEN'S CT-4 - CT-1/G-1, GWB (P-7) CT-1/G-1, GWB (P-7)CT-1/G-1, GWB (P-7) CT-1/G-1, GWB (P-7) GWB (P-7) EXIST ACCESS PANELS TO MATCH ADJACENT MATERIAL COLOR 104 EXIT HALLWAY CT-4 RB-1 GWB (P-7) GWB (P-7) GWB (P-7) GWB (P-7) GWB (P-7) EXIST 105 DELI PREP CT-2 CT-2 - MATCH EXIST TILE MATCH EXIST FRP EXIST MATCH EXIST ACT MATCH EXIST SEE REFERENCE PLAN FOR FRP & TILE LOCATION. ALL HEADERS/SOFFITS TO BE P-7 U.N.O., MATCH EXISTING WALL TILE HEIGHT 106 KITCHEN SERVICE CT-2 CT-2 EXIST MATCH EXIST FRP MATCH EXIST FRP EXIST MATCH EXIST ACT MATCH EXIST 107 35° STOR COOLER MFG MFG MFG MFG MFG MFG MFG 108 -10° FREEZER MFG MFG MFG MFG MFG MFG MFG 110 30° BEER COOLER CT-4 - EXIST EXIST EXIST EXIST EXIST EXIST MATERIAL SCHEDULE CODE DESCRIPTION MFR. NAME COLOR/FINISH COMMENTS 1. TILE/GROUT CT-1 12" X 24" PORCELAIN TILE EMSER PERSPECTIVE BROWN W/ G-2 GROUT, W/ "A100 ABGB" (SCHLUTER-JOLLY TRIM).STAGGERED VERTICAL BRICKWORK PATTERN CT-2 6" X 6" CERAMIC TILE EMSER EQUARRY SMOKE W/ COVE BASE, W. G-1 GROUT CT-3 4" x 12" WALL TILE EMSER LOGIC WHITE WHITE MATTE W/ G-1 GROUT. STAGGERED HORIZONTAL BRICKWORK PATTERN. SEE SHEET A1.07 FOR SS CORNER GUARD LOCATIONS. CT-4 6" X 36" PORCELAIN TILE CONTEMPO CORTEX BROWN W/ G-1 GROUT @ 33% OFFSET, W/ BLACK RUBBER BASE (RB-1) G-1 GROUT CUSTOM BUILDING PRODUCTS -#540 TRUFFLE G-2 GROUT CUSTOM BUILDING PRODUCTS - #185 NEW TAUPE 2. RUBBER BASE RB-1 6" WALL BASE JOHNSONITE WALL BASE #40 BLACK 3. FIBERGLASS REINFORCED PANEL FRP-1 FIBERGLASS PANEL -- MANUFACTURER'S STANDARD WHITE NOTE: FRP SHOULD BE CUT FROM 12' PANELS ONLY. ALL INSIDE AND OUTSIDE CORNERS AND DIVIDERS SHOULD BE CUT ABOVE RUBBER BASE BY RUBBER BASE INSTALLER TO ENSURE TRIMS MEET BASE ELEVATIONS. NO RUBBER BASE OVER THE TOP OF ANY FRP TRIMS. CEILING SUB SHOULD CUT ALL FRP TRIMS AT CEILING ELEVATION. NO L METAL OVER THE TOP OF FRP TRIMS. 4. PAINTED SURFACES P-1 LATEX PAINT SHERWIN WILLIAMS #6120 BELIEVABLE BUFF P-2 LATEX PAINT SHERWIN WILLIAMS #6385 DOVER WHITE P-3 LATEX PAINT SHERWIN WILLIAMS #7043 WORLDLY GRAY P-4 PRIMER (EXTERIOR GRADE) -SW "SAFETY RED" P-5 PRIMER INTERIOR GRADE) SHERWIN WILLIAMS GRAY P-6 LATEX PAINT SHERWIN WILLIAMS #7019 GAUNTLET GRAY P-7 LATEX PAINT SHERWIN WILLIAMS #6225 SLEEPY BLUE P-8 LATEX PAINT SHERWIN WILLIAMS WHITE VERIFY COLOR WITH OWNER P-9 POWDER COAT SHERWIN WILLIAMS #7020 BLACK FOX 5. ACOUSTICAL TILE ACT-1 ACOUSTICAL TILE U.S.G.MANUF. STANDARD WHITE VINYL COATED 6. SOLID SURFACE SS-1 SOLID SURFACE CORIAN PINE GENERAL COUNTERTOPS, WINDOW SILLS, BONFIRE WALL CAP 8. BATHROOM PARTITIONS PT-1 BATHROOM PARTITION BOBRICK PARTITION SIERRA SERIES SC-02 DESERT BEIGE SOLID COLOR REINFORCED COMPOSITE. PARTITION LATCH BOBRICK MODEL 1002612 11. PLASTIC LAMINATE BASE CABINETS, COUNTERTOPS, AND SHELVES PL-1 PLASTIC LAMINATE WILSONART OLD MILL OAK 7973 GENERAL CABINETS PL-2 PLASTIC LAMINATE WILSONART RUSTIC SLATE 4888-38 BONFIRE GRILL WALL 12. ALUMINUM STOREFRONT SYSTEM AST-1 ALUMINUM STOREFRONT KWANEER ANODIZED DARK BRONZE NO SUBSTITUTION 13. SEALANTS SEL-2 SEALANT MATCH COLOR AST-1 MATCH COLOR AST-1 SEL-3 SEALANT BLACK BLACK SEE SPECIFICATIONS SEL-4 SEALANT MATCH COLOR P-1 MATCH COLOR P-1 SEE SPECIFICATIONS SEL-5 SEALANT MATCH COLOR SS-2 MATCH COLOR SS-2 SEL-6 SEALANT L&M (LATICRETE) SEAL HARD CLEAR 14. STANDING SEAM METAL ROOF C-2 METAL ROOF MBCI BRITE RED 15. EXTERIOR STONE VENEER WAINSCOT BR-1 MANUFACTURED STONE CULTURED STONE MATCH EXISTING MATCH EXISTING USE STONE RECEPTACLE BASES FOR ALL RECEPTACLES WITHIN THE STONE AREA FROM THE STONE VENEER MANUFACTURER. COLOR TO MATCH EXISTING. GROUT TO MATCH EXISTING STUCCO. BR-2 MANUFACTURED STONE CULTURED STONE CAP MATCH EXISTING MATCH EXISTING COLOR TO MATCH EXISTING PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY: APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSIO N OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.10/8/2020 11:29:24 AMFINISH & MATERIAL SCHEDULES 2020020.47 FINAL DRAWINGS 07/10/20 XX XX TYPE B REMODEL A6.03MAVERIK, INC.3202 W. USTICK RD.MERIDIAN, ID 83646MAVERIK C-STORE #405GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 10/09/20 DESIGN CRITERIA: STRUCTURAL DRAWINGS HAVE BEEN PREPARED IN ACCORDANC E WITH THE 2018 INTERNATIONAL BUILDING CODE WITH LOCAL AMENDMENTS. LIVE LOADS: ROOF LOAD = 20 PSF (REDUCIBLE AS PER CODE) FLOOR SLAB-ON-GRADE = 100 PSF DEAD LOADS: ROOF LOAD = 20 PSF WIND LOADS: ULTIMATE WIND SPEED, Vult (3 sec. GUST) = 105 MPH NOMINAL WIND SPEED, Vasd (3 sec. GUST) = 81 MPH WIND IMPORTANCE FACTOR ( I w) = 1.0 RISK CATEGORY: II WIND EXPOSURE = C ENCLOSED BUILDING INTERNAL PRESSURE COEFFICIENT = +0.18 or -0.18 SEISMIC LOADS: SEISMIC IMPORTANCE FACTOR: 1.0 RISK CATEGORY: II MAPPED ACCELERATIONS: Ss:0.291g S1:0.103g SITE CLASS DEFINITION: D (ASSUMED) SPECTRAL RESPONSE COEF: Sds:0.304 Sd1:0.163 SEISMIC DESIGN CATEGORY: C RESPONSE MODIFICATION FACTOR (R): 6 1/2 SEISMIC FORCE RESISTING SYSTEM: LIGHT FRAME (COLD FORMED STEEL) WALLS SHEATHED WITH WOOD STRUCTURAL PANEL RATED FOR SHEAR RESISTANCE. ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE SNOW LOADS: GROUND SNOW LOAD (Pg): 20 PSF SNOW EXPOSURE FACTOR (Ce): 1.0 THERMAL FACTOR (Ct): 1.0 SNOW IMPORTANCE FACTOR: 1.0 FLAT ROOF SNOW LOAD (Pf): 25 PSF (MIN. PER LOCAL COD E) CONCRETE NOTES: MINIMUM CONCRETE COMPRESSIVE STRENGTH, (f'c), AT 28 DAYS: 1. BUILDING SLAB: 4000 PSI (EXPOSURE CLASS F0) CONCRETE PROPORTIONS SHALL CONSIST OF THE FOLLOWING MATERIALS TO ACHIEVE A MIX THAT WILL YIELD A FINISHED PRODUCT THAT WILL PRODUCE THE REQUIRED COMPRESSIVE STRENGTHS LISTED ABOVE. A. CEMENTITIOUS MATERIALS: a. PORTLAND CEMENT, ASTM C150, TYPE 1. b. 20% MAXIMUM FLY ASH IS ALLOWED. (ASTM C618, CLA SS F) B. AGGREGATES: NORMAL WEIGHT ASTM C33 a. COMBINED AGGREGATE GRADATION FOR SLABS AND OTH ER DESIGNATED CONCRETE SHALL BE 8% - 18% FOR LARGE TOP SIZE AGGREG ATES (1 1/2") OR 8% - 22% FOR SMALLER TOP SIZE AGGREGATES (1" OR 3/4") RETAINED ON EACH SIEVE BELOW THE TOP SIZE AND ABOVE THE NO. 100. b. A GRADATION CHART OR TABLE SHALL BE SUBMITTED WITH MIX DESIGNS FOR SLAB ON GRADE. NOTIFY E.O.R. IF SPECIF IED GRADATION IS NOT LOCALLY AVAILABLE FOR AN ALTERNATE SPECIFICA TION. c. MAXIMUM AGGREGATE SIZE SHALL NOT BE LARGER THA N: 1. 1/5 THE NARROWEST DIMENSION OF THE FORMS. 2. 1/3 THE DEPTH OF THE SLAB. 3. 3/4 THE MINIMUM CLEAR SPACING BETWEEN BARS. C. WATER: ASTM C94, POTABLE. D. AIR ENTRAINMENT ADMIXTURE: ASTM C260. E. WATER REDUCING ADMIXTURE: ASTM C494, TYPE F OR G . F. CALCIUM CHLORIDE: ANY ADMIXTURE CONTAINING MORE THAN 0.1% CHLORIDE IONS, CONTENT BY WEIGHT, ARE NOT PERMITTED . CONCRETE MIX DESIGNS MUST BE SUBMITTED TO THE E.O.R . FOR HIS APPROVAL BEFORE CONSTRUCTION BEGINS. MIX DESIGNS MUST BE SU BMITTED WITH COMPRESSIVE STRENGTH INFORMATION, FOR THAT SPECIFIC MIX, AS PER THE REQUIREMENTS OF CHAPTER 5 OF ACI-318-14. SUBMISSIO NS WITHOUT THIS INFORMATION WILL BE STAMPED "REJECTED" & RETURNED T O THE CONTRACTOR WITHOUT E.O.R. REVIEW. TEST DATA SHALL BE NO OLDER THAN 12 MONTHS. ALL CONCRETE COMPRESSIVE STRENGTH TESTS SHALL BE AVAILA BLE ON THE JOB SITE FOR REVIEW BY THE INSPECTOR. STRUCTURAL MEMBERS OF REINFORCED CONCRETE SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CODE REFERENCED ACI 318-14. SLAB ON GRADE CONTROL OR CONSTRUCTION JOINTS SHALL BE LOCATED AT COLUMN LINES AND INTERMEDIATELY SO THAT NO JOINT SPACING SHALL EXCEED 12'-0", NOR SHALL THE LENGTH OF ANY PANEL EXCEED ON E AND A HALF, (1 1/2), TIMES THE WIDTH OF THAT PANEL. REFER TO TYPICAL DET AILS FOR SLAB JOINT CONSTRUCTION. FLOOR SLAB CONSTRUCTION JOINTS MUST BE DOWELED. REFER TO ARCHITECTURAL AND MECHANICAL DRAWINGS FOR SLAB FINISHES, SLOPES AND DEPRESSIONS OF INTERIOR SLABS. PROVIDE (2)#4 REINFORCING BARS, 3'-0" LONG, IN CONC RETE SLABS AT ALL RE- ENTRANT CORNERS. PLACE BARS AT MID DEPTH OF SLAB W ITH 2" MINIMUM HORIZONTAL CLEARANCE FROM SLAB CORNER. REINFORCING STEEL NOTES: SHALL BE DETAILED, FABRICATED AND PLACED ACCORDING TO THE LATEST STANDARDS OF THE AMERICAN CONCRETE INSTITUTE (ACI) AND THE CONCR ETE REINFORCING STEEL INSTITUTE (CRSI). MATERIALS: REINFORCING BARS SHALL COMPLY WITH ASTM A615 GRADE 60. WELDED WIRE FABRIC SHALL COMPLY WITH ASTM A82 AND A 1064, FLAT SHEETS ONLY. REINFORCING BARS FOR WELDING SHALL COMPLY WITH ASTM A706. CLEAR MINIMUM COVER OF CONCRETE OVER REINFORCING BA RS SHALL BE AS FOLLOWS: CONCRETE PLACED AGAINST EARTH .........................................3" FORMED SURFACES EXPOSED TO EARTH ............................ ......2" TOP OF SLABS ........................................................................... 3/4" ALL BARS DENOTED CONTINUOUS ON PLANS, SECTIONS AND DETAILS SHALL HAVE CLASS "B" TENSION SPLICE LAPS AND CORNER BARS AND HOOKS A T DISCONTINUOUS ENDS. SPLICED BARS SHALL BE SECURELY WIRED TOGETHER. SPL ICES OF ADJACENT REINFORCING BARS SHALL BE STAGGERED 24" WHEREVER PO SSIBLE. WELDED WIRE FABRIC, WHERE REQUIRED, SHALL BE PLACED IN THE CENTER OF THE SLAB UNLESS NOTED OTHERWISE. LAP JOINTS ONE WIRE SPACIN G PLUS 2" OR A MINIMUM OF 6". EXTEND FABRIC TO WITHIN 1" OF EDGES OF SLABS ON GRA DE. PROVIDE PRECAST DOBIES, WIRE OR PLASTIC CHAIRS, SUP PORT BARS, ETC. TO MAINTAIN SPECIFIED CLEARANCES FOR THE ENTIRE LENGTH OF ALL R EINFORCING BARS AND WELDED WIRE FABRIC. DO NOT USE REBAR STAKES TO SUPPORT REINFORCING. ALL REINFORCEMENT SHALL BE FASTENED AND SECURED TO PREV ENT DISPLACEMENT BY THE PLACING OF CONCRETE. ALL CONCRETE WALLS TO BE DETAILED IN ELEVATION ON S HOP DRAWINGS. NO MORE THAN 50% OF HORIZONTAL WALL REINFORCING SHALL LAP IN A S INGLE VERTICAL PLANE. PROVIDE (2) #4 REINFORCING BARS, 4'-0" LONG, IN CON CRETE SLABS AT ALL RE-ENTRANT CORNERS. PLACE BARS AT MID DEPTH OF SLAB WITH 2" M INIMUM HORIZONTAL CLEARANCE FROM SLAB CORNER. REBAR FOR WELDED CONNECTIONS MUST MEET ASTM A706. STANDARD ASTM A615 GRADE 60 REBARS ARE NOT ACCEPTABLE FOR WELDING. WELDING P ROCEDURE SHALL CONFORM TO ANSI/AWS D1.4 "STRUCTURAL WELDING CODE - REINFORC ING STEEL". DO NOT TACK WELD. REINFORCING DOWELS, WHERE REQUIRED, SHALL MATCH THE SIZE, SPACING AND QUANTITY OF MAIN REINFORCING, UNLESS NOTED OTHERWIS E. TYPICAL DETAILS AND GENERAL NOTES APPLY TO ALL PART S OF THE WORK EXCEPT WHERE SPECIFICALLY DETAILED OR UNLESS OTHERWISE NOT ED. DRAWINGS ARE NOT TO BE SCALED. FOR DIMENSIONS NOT SHOWN, COORDINATE WITH ARCHITECT URAL DRAWINGS. THE CONTRACTOR SHALL CAREFULLY REVIEW THE DRAWINGS TO IDENTIFY THE SCOPE OF WORK REQUIRED, VISIT THE SITE TO RELATE THE SCOPE OF WORK TO EXISTING CONDITIONS, AND DETERMINE THE EXTENT OF WHICH THOSE CONDITIONS AND PHYSICAL SURROUNDINGS WILL IMPACT THE WORK. EXISTING CONDITIONS, AS SHOWN ON THESE PLANS, ARE F OR REFERENCE ONLY. THE CONTRACTOR IS REQUIRED TO FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL ASSUME THE MOST STRINGENT REQU IREMENTS APPLY IN CASE OF CONFLICT AMONG SPECIFICATIONS, STANDARDS, C ODES AND DRAWINGS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER IMMEDIATELY TO RESOLVE THE CONFLICT. ANY DEVIATION, MODIFICATION, OR SUBSTITUTION FROM T HE BID SET OF STRUCTURAL DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT AND ENGINEER FOR REVIEW/APPROVAL PRIOR TO ITS USE OR INCLUSION O N THE SHOP DRAWINGS. WITHOUT SUCH PRIOR APPROVAL, DEVIATIONS, MODIFICATIONS, OR SUBSTITUTIONS WILL BE REJECTED. COSTS FOR DEMOLITION AND REWORK OF SUCH ITEMS WILL BE BORNE BY THE CONTRACTOR. THE STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE BUILDING IS FULLY COMPLETED FOR IN-SERVICE LOADS ON LY. THE MEANS, METHODS, PROCEDURES, AND SEQUENCES OF CONSTRUCTION ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR, WHICH INCLUDE THE DETERMINATION OF ALLOWABLE CONSTRUCTION LOADING OF THE STRUCTURE. T HE CONTRACTOR SHALL PROVIDE, DESIGN, MONITOR, AND MAINTAIN ALL NE CESSARY TEMPORARY AND PERMANENT SYSTEMS (SHORING, BRACING, GUYS, FALS EWORK, FORMWORK, SHEETING, ETC.) TO ENSURE THE INTEGRITY OF THE STRU CTURE AT ALL STAGES OF CONSTRUCTION. ANY SYSTEMS SHOWN ON THE DOCUMENTS A RE PARTIAL AND SCHEMATIC IN NATURE AND EXTENTS ARE NOT ALL INCLUSIVE. ALL WORK SHALL BE PERFORMED WITHOUT DAMAGE TO ADJACENT EXISTING WORK. SHORING SYSTEMS SHALL BE DESIGNED, SIGNED, AND SEALED BY A PROFESSIONAL ENGINEER LICENSED IN THE JURISDICTION WHERE THE PROJECT IS LOCATED. THE CONTRACTOR IS RESPONSIBLE FOR SITE SAFETY. THE CONTRACTOR AND ALL SUBCONTRACTORS SHALL REVIEW THE STRUCTURAL CONTRACT DOCUMENTS AND SHALL NOTIFY THE STRUCTURAL ENGINEER OF ANY CONFLIC TS BETWEEN THOSE DOCUMENTS AND ANY SAFETY REGULATIONS. SUCH REVIEW AND NOTIFICATION SHALL OCCUR PRIOR TO PRODUCTION OF SHOP DRAWINGS. THE CONTRACTOR SHALL PROTECT ALL WORK, MATERIALS, A ND EQUIPMENT FROM DAMAGE AND SHALL PROVIDE PROPER STORAGE FACILITIES FOR MATERIALS AND EQUIPMENT DURING CONSTRUCTION. SITE VISITS PERFORMED BY THE ARCHITECT/ENGINEER DO NOT INCLUDE INSPECTIONS OF MEANS AND METHODS OF CONSTRUCTION PE RFORMED BY THE CONTRACTOR. STRUCTURAL OBSERVATIONS PERFORMED BY THE ARCHITECT/ENGINEER DURING CONSTRUCTION ARE NOT THE CONTINUOUS AND SPECIAL INS PECTION SERVICES AND DO NOT WAIVE THE RESPONSIBILITY FOR THE INSPECT IONS REQUIRED OF THE BUILDING DEPARTMENT INSPECTOR OR THE TESTING AGENCY . ALSO, OBSERVATIONS DO NOT GUARANTEE THE CONTRACTOR'S PERF ORMANCE AND SHALL NOT BE CONSIDERED AS SUPERVISION OF CONSTRUCTION. ALL WALLS, FLOORS, AND ROOF MEMBERS SHALL BE SECURE LY SHORED AND BRACED AT ALL TIMES DURING CONSTRUCTION. NO PIPES OR DUCTS SHALL BE EMBEDDED INTO STRUCTURAL MEMBERS UNLESS SO SHOWN ON THE PLANS OR APPROVED BY THE ENGINEER. NO STRUCTURAL ELEMENTS ARE TO BE CUT UNLESS SPECIFICALLY APPROVED BY THE ENGINEER. GENERAL PROVISIONS: MATERIAL PROPERTIES: W SHAPES: ASTM A992 (Fy = 50 KSI) M,S,C SHAPES: ASTM A36 UNO PLATE, ANGLES: ASTM A36 UNO PIPE: ASTM A53, TYPE E OR S, GRADE B TUBE: ASTM A500, GRADE B (Fy = 46 KSI) DETAILING, FABRICATION, AND ERECTION SHALL CONFORM TO THE 2016 AISC SPECIFICATIONS. FIELD CONNECTIONS SHALL BE BOLTED, BEARING TYPE UNLESS NOTED OTHERWISE USING 3/4" HIGH STRENGTH BOLTS CONFORMING TO ASTM A325. ONE SIDED CONNECTIONS ARE NOT PERMITTED UNLESS DETAILED ON DRAWINGS GENERAL CONTRACTOR SHALL VERIFY ALL MECHANICAL EQUIPMENT LOCATIONS, OPENING DIMENSIONS AND WEIGHTS PRIOR TO STRUCTURAL STEEL FABRICATION. NOTIFY ENGINEER IF DIFFERENT FROM THAT SHOWN ON DRAWINGS. WHEN FORCES ARE NOT SHOWN, THE CONNECTION SHALL DEVELOP 1/2 OF THE ALLOWABLE UNIFORM LOAD AS SPECIFIED IN THE BEAM TABLES OF AISC (ASD). A MINIMUM OF 2 BOLTS SHALL BE USED. ALL WELDING SHALL BE DONE USING E-70XX ELECTRODES IN ACCORDANCE WITH THE LATEST AWS SPECIFICATIONS. FIELD VERIFY ALL CONDITIONS AT AND CONNECTIONS TO THE EXISTING CONSTRUCTION BEFORE FABRICATION. PRIME ALL STEEL NOT IN CONTACT WITH CONCRETE. DO NOT PRIME STEEL IN AREAS TO RECEIVE SLIP CRITICAL BOLTS (FRICTION BOLTS). DO NOT PRIME STEEL THAT IS TO RECEIVE FIREPROOFING. STRUCTURAL STEEL: COMPONENT AND CLADDING WALL PRESSSURE ZONES COMPONENT AND CLADDING ROOF PRESSSURE ZONES ELEVATION PLAN A A A = 9.5 FEET 45 5 A = 9.5 FEET 1 3 2 2 3 33 2 3 2 2 AAA AAAAA PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY:APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSIO N OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.4/15/2021 4:09:34 PMGEN. STRUCTURAL NOTES 2020020.47 FINAL DRAWINGS 07/10/20 Author Approver TYPE B REMODEL S0.01MAVERIK, INC.3202 W. USTICK RD.MERIDIAN, ID 83646MAVERIK C-STORE #405Notes: 1.TRIBUTARY PRESSURES ARE FOR THE SQUARE FOOT (SF) TRIBUTARY AREA SHOWN. FOR OTHER TRIBUTARY AREAS, LINEARLY INTERPOLATE BETWEEN VALUES SHOWN ABOVE. 2.POSITIVE PRESSURES ACT TOWARD THE BUILDING. NEGATIVE PRESSURES ACT AWAY FROM THE BUILDING. 3. ALL WIND PRESSURES IN THE TABLE ARE BASED ON ULTIMATE WINDSPEEDS. TO CONVERT TO NOMINAL WIND PRESSURES MULTIPLE VALUES BY 0.6. -23.9 psf -23.2 psf -22.2 psf 5 17.8 psf 17.5 psf 17.0 psf -19.4 psf -19.0 psf -18.5 psf 4 17.8 psf 17.5 psf 17.0 psf Walls: Zone:10 SF 50 SF 100 SF Overhang Zone 3 -50.1 psf -35.1 psf -16.5 psf Overhang Zone 2 -31.6 psf -30.9 psf -29.9 psf -50.1 psf -37.4 psf -21.5 psf 3 16.0 psf 16.0 psf 16.0 psf -33.3 psf -28.0 psf -21.5 psf 2 16.0 psf 16.0 psf 16.0 psf -19.8 psf -19.1 psf -18.2 psf Roof: 1 16.0 psf 16.0 psf 16.0 psf Zone: 10 SF 50 SF 100 SF C&C Wind Pressures (105 MPH) GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 3 AHJ COMMENTS 4/15/21 3 3 3 04/15/21 GENERAL: METAL STUD MANUFACTURER SHALL BE A MEMBER OF THE ST EEL STUD MANUFACTURER'S ASSOCIATION (SSMA) METAL STUDS AND ACCESSORIES SHALL HAVE A G60 GALVAN IZED COATING UNLESS NOTED OTHERWISE METAL STUD STRENGTH CRITERIA: A. GAUGES 20 THROUGH 18 - 33 KSI MIN. YIELD STRES S B. GAUGES 16 THROUGH 12 - 50 KSI MIN. YIELD STR ESS C. TRACK RUNNER - 33 KSI MIN. YIELD STRESS METAL STUD MEMBER DESIGNATION: 600 S 162 - 33 WEB DEPTH: 600 = 6" MEMBER TYPE: S = STUD FLANGE WIDTH: 162 = 1.625" (1 5/8") MINIMUM THICKNESS IN MILS FASTENERS: FASTENING: WALL OPENING FRAMING: ALL STUDS CUT TO CREATE WALL OPENING MUST BE REPLACED WITH EQUAL FULL HEIGHT KING STUDS ON EACH SIDE OF THE OPENING. CURTAIN WALL AND NON LOAD BEARING PARTITIONS: MECHANICAL BRACING OF STUDS IS NOT NECESSARY WHERE WALL SHEATHING IS ATTACHED ON BOTH SIDES OF THE STUDS. WHEN ONLY ONE FACE OF THE STUDS RECEIVE SHEATHING, PROVIDE BRACING BY ONE OF THE FOLLOWING METHODS: VERTICAL SPACING OF THE BRACING IS LIMITED TO A MAX IMUM OF 4'-0" THROUGHOUT THE HEIGHT OF THE WALL. PROVIDE ALL ACCESSORIES AS REQUIRED BY THE METAL ST UD MANUFACTURER. JOISTS SHALL BE FABRICATED TO PROVIDE 12" OF UNPUNC HED WEB AT BEARING ENDS. PROVIDE JOIST WEB STIFFENERS AT BEARING POINTS WHER E INDICATED ON THE PLANS. PROVIDE END BLOCKING WHERE JOISTS ARE NOT RESTRAINE D AGAINST ROTATION. NO LIGHT GAUGE MEMBER, THAT HAS BEEN TRIMMED OR CUT , SHALL BE INSTALLED SO THAT AN EDGE OF A WEB PUNCH OUT OCCURS WITHIN 10 " MINIMUM OF THE TRIMMED OR CUT MEMBER END. ALL MEMBER CUTTING MUST BE PERFORMED USING A SAW OR SHEAR. NO TORCH CUTTING IS ALLOWED AT ANY TIME. ALSO CUTTING OF AD DITIONAL HOLES, OTHER THAN THOSE PROVIDED BY THE MANUFACTURER, IN T HE MEMBER WEB IS NOT PERMITTED AT ANY TIME. SPLICING OF AXIALLY LOADED MEMBERS IS NOT ALLOWED A T ANY TIME. BUILT-UP LIGHT GAUGE HEADERS, CONSTRUCTED FOR EXTER IOR WALL CONDITIONS, SHALL HAVE INSULATION PLACED WITHIN THE M PRIOR TO THEIR INSTALLATION IN WALL SYSTEM. MILS GAUGE 33 20 43 18 54 16 68 14 97 12 SCREW CONNECTIONS FASTENING STUD TO STUD USE #10-16 TEKS/3 x 5/8" LONG BY ITW BUILDEX UNLESS OTHERWISE NOTED. MIN. EDGE DISTANCE = 3/4" MIN. SPACING BETWEEN FASTENERS = 3/4" POWDER ACTUATED FASTENERS (P.A.F.): FASTENING TO CONCRETE: USE 0.145" DIA. DOME HEAD NAIL BY HILTI, UNLESS NOTED OTHERWISE. MIN. EMBEDMENT = 1 1/4" MIN. EDGE DISTANCE = 2" MIN. SPACING BETWEEN FASTENERS = 3" FASTENING TO STEEL: USE 0.145" DIA. DOME HEAD KNURLED SHANK FASTENER BY HILTI, UNLESS NOTED OTHERWISE. MIN. EMBEDMENT = FULL PENETRATION MIN. EDGE DISTA NCE = 1/2" MIN. SPACING BETWEEN FASTENERS = 1" A. B. MINIMUM FASTENING REQUIREMENTS, UNLESS NOTED OTHERW ISE. TRACK TO CONCRETE: (2) FASTENERS AT 16" O.C. TYPICAL WITH ADDITIONAL F ASTENER 3" FROM END OF TRACK AND (2) FASTENERS MINIMUM AT JAMBS. TRACK TO STRUCTURAL STEEL: 12" O.C. TYPICAL WITH ADDITIONAL FASTENER 3" FROM E ND OF TRACK AND (2) FASTENERS MINIMUM AT JAMBS. STUD TO TRACK: (1) SCREW MINIMUM AT EACH FLANGE STUD TO STUD: (3) SCREWS MINIMUM STUD TO STEEL OR CONCRETE: USE POWDER ACTUATED FASTENERS REFERENCED ABOVE. SEE DETAILS FOR CONNECTIONS, MINIMUM 2 FASTENERS. A. COLD ROLLED CHANNEL, RUN HORIZONTALLY THROUGH STUD PUNCH OUTS AND ATTACHED AT EACH STUD. 2" WIDE, 18 GAUGE, STEEL STRAPS RUN HORIZONTALLY, O N BOTH SIDES OF THE STUDS, AND ATTACHED AT EACH STUD. A. B. PRE-ENGINEERED COLD-FORMED STEEL FRAMING: AB ABV ALT APPROX ARCH BLDG BLW BM B.N. BOT BRG BTWN CC. CC-x CGS C.J. COL CONC CONST CP-x CTR CW-x DB DBA DBE DBL DET DIA DIM DN DWG DWL EA E.N. E.F. E.J. ELEC ELEV E.O.D. E.O.S. EQUIP EQ E.W. EXP EXT FC-x F.D. FDN F.F. F.N. FR-x FS-x FT FTG FTS-x GA GALV GSN HB HORIZ HSA HT ICC IBC I.F. IN INT JT JST ANCHOR BOLT(S) ABOVE ALTERNATE APPROXIMATE ARCHITECT(URAL) BUILDING BELOW BEAM BOUNDARY NAILING BOTTOM BEARING BETWEEN CENTER-TO-CENTER CONCRETE COLUMN CENTER OF GROSS STEEL CONST/CONTROL JOINT COLUMN CONCRETE CONSTRUCTION CONCRETE PIER CENTER CONCRETE WALL DECK BEARING DEFORMED BAR ANCHOR DECK BEARING ELEVATION DOUBLE DETAIL DIAMETER DIMENSION DOWN DRAWING DOWEL EACH EDGE NAILING EACH FACE EXPANSION JOINT ELECTRICAL ELEVATION EDGE OF DECK EDGE OF SLAB EQUIPMENT EQUAL EACH WAY EXPANSION EXTERIOR CONTINUOUS FOOTING MARK FLOOR DRAIN FOUNDATION FINISHED FLOOR FIELD NAILING RECTANGULAR FOOTING SQUARE FOOTING MARK FOOT FOOTING THICKEN SLAB MARK GAUGE GALVANIZED GENERAL STRUCTURAL NOTES HORIZONTAL BRIDGING HORIZONTAL HEADED STUD ANCHOR HEIGHT INTERNATIONAL CODE COUNCIL INTERNATIONAL BUILDING CODE INSIDE FAVE INCH INTERIOR JOIST JOINT k KLF KSF LBS LF LLH LLV LSH LSV MAX MECH MF-x MFR MIN MISC NIC NTS O.C. O.F. OPNG OPP OWSJ PAF PCF PL PLF PNL PSF PSI PT REINF REQD R.D. RTU SBP-x SCW SC-x SCP-x SHT SI SIM SMU SOG SQ STAG STD STL STR STS T&B TEMP THDS T.O. TOC TOD TOF TOS TOW TYP UNO VERT W/ WT WWF WWM KIP(S) = 1000 POUNDS KIPS PER LINEAL FOOT KIPS PER SQUARE FOOT POUNDS LINEAL FOOT LONG LEG HORIZONTAL LONG LEG VERTICAL LONG SIDE HORIZONTAL LONG SIDE VERTICAL MAXIMUM MECHANICAL MOMENT FRAME MANUFACTURER MINIMUM MISCELLANEOUS NOT IN CONTRACT NOT TO SCALE ON CENTER OUTSIDE FACE OPENING OPPOSITE OPEN WEB STEEL JOIST POWER-ACTUATED FASTENER POUNDS PER CUBIC FOOT PLATE POUNDS PER LINEAL FOOT PANEL POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH POINT REINFORCING REQUIRED ROOF DRAIN ROOF TOP UNITS STEEL BASE PLATE MARK SEISMIC CRITICAL WELD STEEL COLUMN MARK STEEL CAP PLATE MARK SHEET SPECIAL INSPECTION SIMILAR SUSPENDED MECHANICAL UNITS SLAB-ON-GRADE SQUARE STAGGARD STANDARD STEEL STRUCTURAL SELF TAPPING SCREWS TOP AND BOTTOM TEMPERATURE THREADS TOP OF TOP OF CONCRETE TOP OF DECK TOP OF FOOTING TOP OF STEEL TOP OF WALL TYPICAL UNLESS NOTED OTHERWISE VERTICAL WITH WALL THICKNESS WELDED WIRE FABRIC WELDED WIRE MESH LEGEND OF MARKS AND ABBREVIATIONS REPRODUCTION OF THE STRUCTURAL DRAWINGS FOR USE IN PREPARATION OF SHOP DRAWINGS IS STRICTLY PROHIBITED WITHOUT THE WRITTEN CONSENT OF THE ENGINEER OF RECORD. SHOP DRAWINGS SUBMITTED WITH R EPRODUCED STRUCTURAL DRAWINGS AND/OR DETAILS WITHOUT CONSENT WILL BE REJECTED. SUBMIT SHOP DRAWINGS 15 BUSINESS DAYS (MINIMUM) PRIOR TO DATE THAT RETURNED SHOP DRAWINGS ARE REQUIRED. SHOP DRAWINGS SHALL BEAR THE CONTRACTORS STAMP OF A PPROVAL, WHICH SHALL CONSTITUTE CERTIFICATION THAT ALL FIELD MEASU REMENTS, CONSTRUCTION CRITERIA, AND MATERIALS SPECIFIED IN T HE CONTRACT DOCUMENTS HAVE BEEN VERIFIED AND EACH DRAWING HAS B EEN CHECKED FOR COMPLETENESS, COORDINATION, AND COMPLIANCE WITH THE CONTRACT DOCUMENTS. CONTRACTOR SHALL REFER TO ARCHITECTURAL, MECHANICAL, PLUMBING, ELECTRICAL, LAUNDRY AND FOOD SERVICE DRAWINGS FOR SIZE AND LOCATIONS OF OPENINGS, SLEEVES, CONCRETE HOUSEKEEPING PADS, INSE RTS, AND DEPRESSIONS DURING SHOP DRAWING PREPARATION. WHERE A DELEGATED DESIGN IS INDICATED ON THE DRAWIN GS, THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AND CALCULATIONS FOR EAC H ITEM, COMPONENT, AND CONNECTION NOT SPECIFICALLY DETAILED ON THE STR UCTURAL DRAWINGS. SHOP DRAWINGS AND DESIGN CALCULATIONS SHALL BE SIGN ED AND SEALED BY THE CONTRACTOR'S LICENSED ENGINEER (IN THE PROJECT'S JU RISDICTION). DRAWINGS AND CALCULATIONS SHALL SHOW LOCATIONS AND MAGNITUDE S OF LOADS IMPOSED ON THE STRUCTURE. THE ENGINEER OF RECORD RESERVES THE RIGHT TO MODIFY LOAD PATH SUGGESTED BY THE DELEGATED DESIGN ENGINEE R. SHOP DRAWINGS: SHOP DRAWING NOTES: CONTRACTOR SHALL FURNISH COMPLETE AND DETAILED SHOP DRAWINGS FOR THE FOLLOWING STRUCTURAL MATERIALS: STRUCTURAL STEEL OPEN-WEB STEEL JOIST & METAL ROOF DECK REINFORCING STEEL CONCRETE MIX DESIGN COLD FORMED STEEL FRAMING UNLESS NOTED, SUBMIT SHOP DRAWINGS FOR ALL FABRICAT ED MATERIALS. ALL SHOP DRAWINGS MUST BEAR THE REVIEW STAMP OF THE GENERAL CONTRACTOR. UNSTAMPED SHOP DRAWINGS WILL BE REJECTED WITHOUT RE VIEW. ELECTRONIC COPIES OF SHOP DRAWINGS SHALL BE SUBMITT ED TO ENGINEER OF RECORD. ELECTRONIC COPIES OF SHOP DRAWINGS WILL ONLY BE ACCEPTED WITH THE APPROVAL OF THE ENGINEER OF RECORD. REPRODUCTION O F ELECTRONIC COPIES WILL BE BILLED TO GENERAL CONTRACTOR FOR REIMBURSEM ENT OF PRINTING COSTS. DESIGN DRAWINGS SHALL NOT BE REPRODUCED FOR USE AS SHOP DRAWINGS. TWO SETS OF REVIEWED SHOP DRAWINGS WILL BE RETURNED TO THE GENERAL CONTRACTOR. ALLOW MINIMUM 10 WORKING DAYS FOR ARCHITECT/ENGINEE R REVIEW OF EACH SHOP DRAWING SUBMITTAL. ALLOW AN ADDITIONAL WORKING DAY FOR EVERY 5 DRAWINGS OVER 30. SHOP DRAWINGS FOR CONSTRUCTION OF EACH BUILDING COM PONENT NOT DESIGNED BY THE DESIGN ENGINEER OF RECORD AND NOT SPECIFIED IN THE CONSTRUCTION DOCUMENTS SHALL BE SIGNED & SEALED BY A PROFESSIONA L ENGINEER REGISTERED IN THE STATE OF THE PROJECT. COMPONENTS INCLUDE BU T ARE NOT LIMITED TO THE FOLLOWING: PRE-ENGINEERED TRUSSES, RAILINGS, LADDE RS, LIGHT GAUGE STUD FRAMING, RACK SYSTEMS, GLAZING SYSTEMS, AWNINGS AND ANY OTHER ITEM THAT IS DESIGNATED AS "DESIGNED BY OTHERS" OR "PRE-ENGINEER ED". THESE SHOP DRAWINGS SHALL BEAR CLEAR INDICATION THAT THEY HAVE BEEN REVIEWED AND APPROVED BY THE PROJECT ARCHITECT OR ENGINEER OF RE CORD. SHOP DRAWINGS SUBMITTED TO THE ENGINEER OF RECORD SHALL ADHERE TO THE FOLLOWING GUIDELINES OR THEY WILL BE REJECTED AND R ETURNED TO SENDER UNCHECKED: DETAILER SHALL COORDINATE WITH ARCHITECTURAL AND ME CHANICAL DRAWINGS FOR ALL ATTACHMENTS, CLIPS, OPENINGS OR DUCTWORK AF FECTING STRUCTURAL MEMBERS. ALL ITEMS SHALL BE SHOWN ON SHOP DRAWINGS . DIMENSIONAL COORDINATION SHALL BE PERFORMED BY THE GENERAL CONTRACTOR AND/OR HIS FABRICATOR. PROPOSED CHANGES TO THE CONSTRUCTION DOCUMENTS SHALL BE CLEARLY MARKED IN THE SHOP DRAWINGS AND SHALL INCLUDE SIGNED & SE ALED DRAWINGS AND CALCULATIONS BY AN ENGINEER REGISTERED IN THE STATE WHERE THE PROJECT IS LOCATED. THE ENGINEER OF RECORD WILL REVIEW THE PR OPOSED CHANGE FOR ACCEPTANCE. THE CONTRACTOR SHALL HAVE PROOF OF WELDER CERTIFICA TION AT THE JOBSITE AT ALL TIMES. APPROVED SHOP DRAWINGS SHALL BE AVAILABLE AT THE JO BSITE AT ALL TIMES. THE LATEST ISSUE DATE, IN THE DRAWING REVISION BOX, OF ANY SHEET IN THE STRUCTURAL DRAWING SET, SHALL BE CLEARLY SHO WN ON THE TOP SHEET OF THE SHOP DRAWINGS. NO PARTIAL SETS WILL BE ACCEPTED, UNLESS PREVIOUSLY APPROVED BY THE ENGINEER OF RECORD. STEEL JOIST SUBMITTALS SHALL HAVE JOB SPECIFIC DETA ILS IN ADDITION TO THE JOIST MANUFACTURER'S TYPICAL DETAILS. A. B. C. SPECIAL INSPECTION AND TESTING: THE SPECIAL INSPECTIONS & TESTING PROGRAM: THE SPECIAL INSPECTION AND TESTING PROGRAM IS A QUA LITY ASSURANCE PROGRAM INTENDED TO ENSURE THAT THE WORK IS PERFORM ED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. THESE INSP ECTIONS ARE IN ADDITION TO THE INSPECTIONS SPECIFIED IN IBC SEC TION 110. THE SPECIAL INSPECTION PROGRAM DOES NOT RELIEVE THE CON TRACTOR OF HIS OR HER RESPONSIBILITY TO COMPLY WITH THE OFFICIAL CONTRACT DOCUMENTS. FURTHER, IT IS NOT INTENDED THAT THE CO NTRACTOR'S CONTRACTUAL AND STATUTORY OBLIGATIONS ARE ANYWAY RE LIEVED OR FOREGONE BY THE PRESENCE OF THE SPECIAL INSPECTOR. THE CONTRACTOR HAS THE SOLE RESPONSIBILITY FOR ANY DEVIATIONS FROM THE OFFICIAL CONTRACT DOCUMENTS. THE SPECIAL INSPE CTOR DOES NOT REPLACE THE DUTIES OF THE BUILDING OFFICIAL NOR THE QUALITY CONTROL RESPONSIBILITIES AND PERSONNEL OF THE CONTR ACTOR. JOB SITE SAFETY AND MEANS AND METHODS OF CONSTRUCTION A RE SOLELY THE RESPONSIBILITY OF THE CONTRACTOR. THE PROJECT OWNER IS RESPONSIBLE FOR EMPLOYING SPEC IAL INSPECTION SERVICES. THE SPECIAL INSPECTOR/AGENCY SHALL NOT B E IN THE EMPLOY OF THE CONTRACTOR, SUBCONTRACTOR OR MATERIAL SUPPLIER, IBC SEC. 1704.1. IN THE CASE OF AN OWNER/CONTRACTOR, THE SP ECIAL INSPECTOR/AGENCY SHALL BE EMPLOYED AS SPECIFIED BY THE BUILDING OFFICIAL. THE SPECIAL INSPECTOR IS OBLIGATED TO BOTH THE OWNE R AND THE BUILDING OFFICIAL FOR OBSERVING THAT THE WORK IS EX ECUTED IN SUBSTANTIVE ACCORDANCE WITH THE OFFICIAL CONTRACT D OCUMENTS. THE OFFICIAL CONTRACT DOCUMENTS ARE DEFINED AS THE PERMITTED PLANS AND SPECIFICATIONS, ADDENDA, CHANGE ORDERS, I SSUED SKETCHES AND REVISION DRAWINGS, AND ALL DIRECTIVES ISSUED BY ARCHITECT/ENGINEER. THE INSPECTION AND TESTING AGENTS SHALL DISCLOSE AN Y PAST OR PRESENT BUSINESS RELATIONSHIP OR POTENTIAL CONFLICT OF INTEREST WITH THE CONTRACTOR OR ANY OF THE SUBCONTRACTORS WH OSE WORK IS TO BE INSPECTED OR TESTED. THE SPECIAL INSPECTORS MAY HAVE NO FINANCIAL INTEREST IN PROJECTS FOR WHICH THEY PROVIDE SPECIAL INSPECTION SERVICES. THIS PROJECT REQUIRES SPECIAL INSPECTION AND TESTIN G IN ACCORDANCE WITH CHAPTER 17 OF THE INTERNATIONA L BUILDING CODE. THESE NOTES AND THE STATEMENT OF SPECIAL INS PECTIONS PREPARED FOR THE PROJECT OWNER ARE INTENDE D TO INFORM THE CONTRACTOR OF THE QUALITY ASSURANCE PROG RAM AND THE EXTENT OF THE CONTRACTORS RESPONSIBILIT IES. SEE SHEET S0.03 FOR SCHEDULE OF SPECIAL INSPECTIONS . SPECIAL INSPECTION REPORT REQUIREMENTS: SPECIAL INSPECTION REPORTS AND A FINAL REPORT IN AC CORDANCE WITH SECTION 1704.2.4 SHALL BE SUBMITTED TO THE BUILDING OFFICIAL PRIOR TO THE TIME THAT PHASE OF THE WORK IS APPROVED FOR OCCUPANCY. REPORT REQUIREMENT: SPECIAL INSPECTORS SHALL KEEP RECORDS OF ALL INSPECTIONS. THE SPECIAL INSPECTOR SHALL FURNISH T HE INSPECTION REPORTS TO THE BUILDING OFFICIAL, AND TO THE REGIST ERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE. REPORTS SHALL INDICATE THAT THE WORK INSPECTED WAS OR WAS NOT COMPLETED IN CONF ORMANCE TO THE APPROVED CONSTRUCTION DOCUMENTS. DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTO R FOR CORRECTION. IF THEY ARE NOT CORRECTED, THE DISCREP ANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE BUILDING OFFICIAL A ND THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARG E PRIOR TO THE COMPLETION OF THAT PHASE OF THE WORK. A FINAL REPO RT DOCUMENTING THE REQUIRED SPECIAL INSPECTIONS AND CO RRECTION OF ANY OF THE DISCREPANCIES NOTED IN THE INSPECTIONS, SHALL BE SUBMITTED TO THE BUILDING OFFICIAL PRIOR TO THE TIM E THAT PHASE OF THE WORK IS APPROVED FOR OCCUPANCY. CONTRACTOR RESPONSIBILITIES: THE CONTRACTOR IS RESPONSIBLE FOR NOTIFYING THE SPE CIAL INSPECTOR IN ADVANCE OF CONSTRUCTION SCHEDULES AND PLANNED OPERA TIONS IN ORDER TO ASSURE TIMELY AND APPROPRIATE INSPECTION FOR THE IT EMS LISTED IN THE SCHEDULE OF SPECIAL INSPECTIONS. THE CONTRACTOR SH ALL PROVIDE ADEQUATE NOTICE TO THE SPECIAL INSPECTOR FOR ALL INSPECTIONS. THE CONTRACTOR SHALL COOPERATE WITH AND ASSIST THE SPECIAL INSPECTOR IN PERFORMING HIS INSPECTION DUTIES. THE SPECIAL INSP ECTOR SHALL HAVE FREE ACCESS TO THE PROJECT AT ALL TIMES. THE CONTRACTOR SHALL REVIEW THE SPECIAL INSPECTION PLAN AND COORDINATE THE SCHEDULE OF WORK TO ACCOMMODATE THE REQUIRED INSPECTIONS. PROVIDE ACCESS TO APPROVED PLANS: THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING THE SPECIAL INSPECTOR ACCESS TO APPROVED PLANS. THE CONTRACTOR SHALL MAINTAIN A CURRENT SET OF THE CONT RACT DOCUMENTS AT THE JOB SITE. CORRECT DISCREPANCIES AND DEVIATIONS: THE CONTRACTO R SHALL, UPON BEING INFORMED BY THE SPECIAL INSPECTOR, IMMEDIATELY CAUS E TO ELIMINATE SUCH DISCREPANCIES AND DEVIATIONS. WORK COMPLETED WITHOUT INSPECTION: WORK REQUIRING INSPECTION WHICH IS COMPLETED WITHOUT INSPECTION WILL BE REJECTED SOLELY ON THAT BASIS. RETAIN SPECIAL INSPECTION RECORDS: THE CONTRACTOR IS ALSO RESPONSIBLE FOR RETAINING AT THE JOB SITE ALL SPECIAL INSPECTIO N RECORDS COMPLETED BY THE SPECIAL INSPECTOR. COORDINATE AND SUBMIT. THE CONTRACTOR IS RESPONSIB LE FOR PREPARING AND SUBMITTING TO THE BUILDING OFFICIAL AND THE OWN ER A STATEMENT OF CONTRACTOR RESPONSIBILITY, IBC SECTION 1704.4, FOR THEMSELVES AND FOR SUBMITTING A STATEMENT OF CONTRACTOR RESPONSIBILITY FOR EACH STRUCTURAL COMPONENT SUBCONTRACTOR. THE STATEMENTS OF RESPONSIBILITY SHALL BE SUBMITTED PRIOR TO THE COMMENCEMENT OF WORK ON THE SYSTEM OR COMPONENT. A.THE STATEMENT OF CONTRACTOR RESPONSIBILITY SHALL CONTAIN THE FOLLOWING: 1. ACKNOWLEDGEMENT OF AWARENESS OF THE SPECIAL REQUIREMENTS CONTAINED IN THE QUALITY ASSU RANCE PLAN. 2. ACKNOWLEDGEMENT THAT CONTROL WILL BE EXERCISED T O OBTAIN CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS APPROVE D BY THE BUILDING OFFICIAL. 3. PROCEDURES FOR EXERCISING CONTROL WITHIN THE CON TRACTOR'S ORGANIZATION, THE METHOD AND FREQUENCY OF REPORTING AND THE DISTRIBUTION OF THE REPORTS. 4. IDENTIFICATION AND QUALIFICATIONS OF THE PERSON S EXERCISING SUCH CONTROL AND THEIR POSITIONS IN THE ORGANIZATIO N. B. STRUCTURAL COMPONENT SUBCONTRACTORS INCLUDE BUT ARE NOT LIMITED TO STRUCTURAL STEEL FABRICATORS AND ERECTOR S, COMPONENT FABRICATORS, SUCH AS STEEL JOISTS, METAL OR WOOD TRUSSES, CONCRETE AND MASONRY CONTRACTORS. C. AT THE COMPLETION OF STRUCTURAL COMPONENT FABRICA TION, THE FABRICATORS SHALL SUBMIT A CERTIFICATE OF COMP LIANCE STATING THAT THE WORK WAS PERFORMED IN ACCORDANCE WITH THE APPROVED CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COSTS OF: RETESTING AND REINSPECTION OF MATERIALS, WORK AND/O R PRODUCTS THAT DO NOT MEET THE REQUIREMENTS OF THE CONTRACT D OCUMENTS AND SHOP DRAWINGS/SUBMITTAL DATA. REVIEW OF PROPOSED REPAIR AND/OR REPLACEMENT PROCED URES BY THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARG E AND THE INSPECTORS AND TESTING AGENCIES. REPAIR OR REPLACEMENT OF WORK THAT DOES NOT MEET TH E REQUIREMENTS OF THE CONTRACT DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR THE TRAVEL COSTS OF THE SPECIAL INSPECTOR OR AGENTS WHEN SHOP INSPECTION IS REQUIRE D OF A NON APPROVED STRUCTURAL COMPONENT FABRICATOR. INSPECTION OF FABRICATION: WHERE FABRICATION OF STRUCTURAL MEMBERS AND ASSEMBLIES ARE PERFORMED ON THE PREMISES OF THE FABRICATOR, THE SHOP FABRICATION REQUIRES SPECIAL INSPECTION DURING THE FABRICATION OF ITEMS FOR THIS PROJECT. EXEMPTION: FABRICATORS APPROVED BY THE BUILDING OFFICIAL ARE E XEMPT FROM THE ON PREMISE INSPECTION. THE APPROVAL BY THE BUILDING OFFICIAL OF ANY FABRICATOR SHOULD BE PROPERLY DOCUM ENTED PRIOR TO THE COMMENCEMENT OF FABRICATION. EXEMPTIO N WILL BE PROVIDED TO FABRICATORS WHO PROVIDE PROOF OF CERTIF ICATION BY A NATIONALLY RECOGNIZED GOVERNING ASSOCIATION WHICH PERFORMS PERIODIC INSPECTIONS AND MAINTAINS QUALITY ASSURANCE CRITERIA. EXAMPLES ARE: AISC CERTIFICATION FOR A STEEL FABRICATOR, SJI CERTIFICATION FOR A STEEL JOIST MAN UFACTURER, WTC AND TPI CERTIFICATION FOR A PRE-ENGINEERED WOOD TRUSS MANUFACTURER. AT THE COMPLETION OF FABRICATION, THE FABRICATOR SHALL SUBMIT A CERTIFICATE OF COMPLIANCE TO THE BUILDING OFFICIAL STATING THAT THE WORK WAS PERFORMED IN ACCORDANCE WITH THE APPRO VED CONSTRUCTION DOCUMENTS. CONCRETE TESTING NOTES: CONCRETE TESTING AND INSPECTION SHALL BE PERFORMED IN ACCORDANCE WITH THE REQUIREMENTS OF ACI 318 AND THE SCHEDULE OF SPECIAL INSPECTIONS. SAMPLES FOR STRENGTH TESTS OF EACH CLASS OF CONCRETE PLACED EACH DAY SHALL BE TAKEN NOT LESS THAN ONCE A DAY, NOR LESS THAN ONCE FOR EACH 75 C.Y. OF CONCRETE USE D FOR FOOTINGS, NOR LESS THAN ONCE FOR EACH 5000 SQUARE FEET OF SUR FACE AREA FOR SLABS. TEST REPORTS INDICATING NON-COMPLIANCE SHALL BE PROVIDED TO THE OWNER, ARCHITECT & CONTRACTOR. A COPY OF TH E TEST REPORTS SHALL BE AVAILABLE AT THE JOBSITE. STEEL INSPECTION & TESTING NOTES: STRUCTURAL STEEL TESTING AND INSPECTION SHALL BE PE RFORMED IN ACCORDANCE WITH THE REQUIREMENTS OF THE REFERENCED STANDARDS AND THE SCHEDULE OF SPECIAL INSPECTIONS. FIELD BOLTED CONNECTIONS WILL BE TESTED AND INSPECT ED ACCORDING TO RCSC'S "SPECIFICATION FOR STRUCTURAL JOINTS USIN G ASTM A325 OR A490 BOLTS." FIELD WELDS SHALL BE INSPECTED AND TESTED ACCORDING TO AWS D1.1. IN ADDITION TO VISUAL INSPECTION, WELDED MOMENT CO NNECTIONS WILL BE TESTED BY ULTRASONIC, ASTM E164, OR OTHER AWS APPROVED METHOD. OTHER REQUIRED INSPECTIONS: THE REQUIREMENTS OF SPECIAL INSPECTIONS AND TESTING IN ACCORDANCE OF THE INTERNATIONAL BUILDING CODE ARE M INIMUM REQUIREMENTS AND DO NOT LIMIT THE REQUIREMENTS FOR THE CONTRACTOR TO PROVIDE OTHER QUALITY CONTROL INSPECT IONS AND TESTING REQUIRED BY THE OWNER, CONTRACT DOCUMENTS, OR OTHER GOVERNING AUTHORITIES HAVING JURISDICTION. PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY: APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSIO N OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.10/8/2020 8:23:18 AMGEN. STRUCTURAL NOTES & SPECIAL INSPECTIONS 2020020.47 FINAL DRAWINGS 07/10/20 Author Approver TYPE B REMODEL S0.02MAVERIK, INC.3202 W. USTICK RD.MERIDIAN, ID 83646MAVERIK C-STORE #405GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 10/09/20 SCHEDULE OF SPECIAL INSPECTIONS 1704.2.5 INSPECTION OF FABRICATORS MATERIAL/ACTIVITY SERVICE APPLICABLE TO PROJECT Y/N EXTENT 1705.2 STEEL CONSTRUCTION VERIFY FABRICATION/QUALITY CONTROL PROCEDURES IN-PLANT REVIEW (3) DURING FABRICATION Y SPECIAL INSPECTIONS ARE NOT REQUIRED WHERE THE FABRICATOR IS REGISTERED AND APPROVED IN ACCORDANCE WITH SECTION 1704.2.5.1. Y Y Y Y Y Y Y Y 1. FABRICATOR AND ERECTOR DOCUMENTS (VERIFY REPORTS AND CERTIFICATES AS LISTED IN AISC 360, CHAPTER N, SECTION N3, PARAGRAPH 2 FOR COMPLIANCE WITH CONSTRUCTION DOCUMENTS) 2. MATERIAL VERIFICATION OF STRUCTURAL STEEL HIGH- STENGTH BOLTS, NUTS, & WASHERS, & WELD FILLER MATERIALS. 3. EMBEDMENTS, VERIFY DIAMETER, GRADE, TYPE, LENGTH , & EMBEDMENT. (SEE 1705.3 FOR ANCHORS) 4. VERIFY MEMBERS LOCATIONS, BRACES, STIFFENERS, AN D APPLICATION OF JOINT DETAILS AT EACH CONNECTION COMPLY WITH CONSTRUCTION DOCUMENTS 5. STRUCTURAL STEEL WELDING a. INSPECTION TASKS PRIOR TO WELDING (OBSERVE, OR PERFORM FOR EACH WELDED JOINT OR MEMBER, THE QA TASKS LISTED IN AISC 360, TABLE N5.4-1) b. INSPECTION TASKS DURING WELDING (OBSERVE, OR PERFORM FOR EACH WELDED JOINT OR MEMBER, THE QA TASKS LISTED IN AISC 360, TABLE N5.4-2) c. INSPECTION TASKS AFTER WELDING (OBSERVE, OR PERFORM FOR EACH WELDED JOINT OR MEMBER, THE QA TASKS LISTED IN AISC 360, TABLE N5.4-3) d. NONDESTRUCTIVE (NDT) TESTING OF WELDED JOINTS: 1) NOT USED 2) COMPLETE PENETRATION GROOVE WELDS 5/16" OR GREATER IN RISK CATEGORY II 5) FABRICATORS NDT REPORTS WHEN FABRICATORS PERFORMS NDT 6. STRUCTURAL STEEL BOLTING: a. INSPECTION TASKS PRIOR TO BOLTING (OBSERVE, OR PERFORM TASKS FOR EACH BOLTED CONNECTION, IN ACCORDANCE WITH QA TASKS LISTED IN AISC 360, TABLE N5.6-1) b. INSPECTION TASKS DURING BOLTING (OBSERVE THE QA TASKS LISTED IN AISC 360, TABLE N5.6-2) 1) PRE-TENSIONED AND SLIP-CRITICAL JOINTS a) NOT USED b) DIRECT TENSION INDICATOR c) TWIST-OFF TYPE TENSION CONTROL BOLT 2) SNUG-TIGHT JOINTS c. INSPECTION TASKS AFTER BOLTING (PERFORM TASKS FOR EACH BOLTED CONNECTION IN ACCORDANCE WITH QA TASKS LISTED IN AISC 360, TABLE N5.6-3) SUBMITTAL REVIEW SHOP (3) AND FIELD INSPECTION FIELD INSPECTION SHOP (3) AND FIELD INSPECTION SHOP (3) AND FIELD INSPECTION SHOP (3) AND FIELD INSPECTION SHOP (3) OR FIELD ULTRASONIC TESTING - 10% OF WELDS MINIMUM VERIFY REPORTS SHOP (3) AND FIELD INSPECTION SHOP (3) AND FIELD INSPECTION AND TESTING EACH SUBMITTAL PERIODIC PERIODIC OBSERVE OR PERFORM AS NOTED (4) OBSERVE (4) OBSERVE OR PERFORM AS NOTED (4) PERIODIC EACH SUBMITTAL (5) OBSERVE OR PERFORM AS NOTED (4) OBSERVE (4) PERIODIC PERIODIC PERFORM (4) MATERIAL/ACTIVITY SERVICE APPLICABLE TO PROJECT Y/N EXTENT YFIELD INSPECTION PERIODIC PERIODIC Y Y Y Y 1. INSPECT REINFORCEMENT, INCLUDING PRESTRESSING TENDONS, AND VERIFY PLACEMENT. 2. REINFORCING BAR WELDING: a. VERIFY WELDABILITY OF REINFORCING BARS OTHER THAN ASTM A706 b. INSPECT SINGLE-PASS FILLET WELDS, MAX. 5/16" c. INSPECT ALL OTHER WELDS. 3. INSPECT ANCHORS CAST IN CONCRETE. 4. INSPECT ANCHORS POST-INSTALLED IN HARDENED CONCRETE MEMBERS. a. ADHESIVE ANCHORS INSTALLED IN HORIZONTALLY OR UPWARDLY INCLINED ORIENTATIONS TO RESIST SUSTAINED TENSION LOADS. b. MECHANICAL ANCHORS AND ADHESIVE ANCHORS NOT DEFINED IN 4.a. 5. VERIFY USE OF REQUIRED DESIGN MIX. 6. PRIOR TO CONCRETE PLACEMENT, FABRICATE SPECIMINS FOR STRENGTH TESTS, PREFORM SLUMP AND AIR CONTENT TESTS, AND DETERMINE THE TEMPERATURE OF THE CONCRETE. 7. INSPECT CONRETE AND SHOTCRETE PLACEMENT FOR PROPER APPLICATION TECHNIQUES 8. VERIFY MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND TECHNIQUES. 9. INSPECT PRESTRESSED CONCRETE FOR: a. APPLICATION OF PRESTRESSING FORCES b. GROUTING OF BONDED PRESTRESSING TENDONS. 10. INSPECT ERECTION OF PRECAST CONCRETE MEMBERS. 11. VERIFY IN-SITU CONCRETE STRENGTH, PRIOR TO STRESSING OF TENDONS IN POST-TENSIONED CONRETE AND PRIOR TO REMOVAL OF SHORES AND FORMS FROM BEAMS AND STRUCTURAL SLABS. 12. INSPECT FORMWORK FOR SHAPE, LOCATION AND DIMENSIONS OF THE CONCRETE MEMBER BEING FORMED. 13. CONRETE STRENGTH TESTING AND VERIFICATION OF COMPLIANCE WITH CONSTRUCTION DOCUMENTS. ACI 318 CH.20, 25.2, 25.3, 26.5.1.-26.5.3 1908.4 AWS D1.4 ACI 318: 26.5.4 ACI 318: 17.8.2 ACI 318: 17.8.2.4 ACI 318: 17.8.2 ACI 318: CH. 19. 26.4.5, 26.4.4 1904.1, 1904.2, 1908.2, 1908.3 ASTM C172 ASTM C31 ACI 318: 26.4.5, 26.12 1908.10 ACI 318: 26.4.5 1908.6, 1908.7, 1908.8 ACI 318: 26.4.7-26.4.9 1908.9 ACI 318: 26.9.2.1 ACI 318.26.9.2.3 ACI 318: CH 26.8 ACI 318: 26.10.2 ACI 318: 26.10.1[b] FOR SI: INCH = 25.4 mm. {a.} WHERE APPLICABLE, SEE ALSO SECTION 1705.12. SPECIAL INSPECTIONS FOR SEISMIC RESISTANCE. {b.} SPECIFIC REQUIREMENTS FOR SPECIAL INSPECTION SHALL BE INCLUDED IN THE RESEARCH REPORT FOR THE ANCHOR ISSUED BY AN APPROVED SOURCE IN ACCORDAN CE WITH 17.8.2 IN ACI 318, OR OTHER QUALIFICATION PROCEDURES. WHERE SPECIFIC REQUIREMEN TS ARE NOT PROVIDED, SPECIAL INSPECTION REQUIREMENTS SHALL BE SPECIFIED BY THE REGISTERED D ESIGN PROFFESIONAL AND SHALL BE APPROVED BY THE BUILDING OFFICIAL PRIOR TO THE COMMENCEMENT OF THE WORK. 1705.3 CONCRETE CONSTRUCTION REFERENCED STANDARD APPLICABLE TO PROJECT Y/N EXTENT MATERIAL/ACTIVITY REFERENCED STANDARD PERIODICY PERIODIC CONTINUOUS PERIODICY Y Y PERIODIC Y Y PERIODIC PERIODIC Y PERIODIC Y CONTINUOUS Y CONTINUOUS PERIODICY N N CONTINUOUS CONTINUOUS N PERIODIC N PERIODIC Y PERIODIC Y PERIODIC NOTES: 1. THE INSPECTION AND TESTING AGENT OR AGENTS, SHALL BE ENGAGED BY THE OWNER OR THE OWNER'S AGENT, AND NOT BY THE CONTRACT OR OR SUBCONTRACTOR WHOSE WORK IS TO BE INSPECTED OR TEST ED. ANY CONFLICT OF INTEREST MUST BE DISCLOSED TO THE BUILDING OFFICIAL PRIOR TO COMMENCING WORK. THE QUALIFICATIONS OF THE SPECIAL INSPECTOR AND/OR TESTING AGENCIES MAY BE SUBJECT TO THE APPROVAL OF THE BUIL DING OFFICIAL AND/OR THE DESIGN PROFESIONAL. 2. SUBMIT A LIST OF THE SPECIAL INSPECTORS ON A SEPARATE DOCUMENT TO THE BUILDING OFFICIAL AND THE DESIGN PROFESSIONAL. 3. SPECIAL INSPECTIONS AS REQUIRED BY SECTION 1704.2.5 ARE NOT REQUIRED WHERE THE FABRICATOR IS APPROVED IN ACCORDANCE WITH IBC SECTION 1704.2.5.1. 4. OBSERVE ON A RANDOM BASIS, OPERATIONS NEED NOT B E DELAYED PENDING THESE INSPECTIONS. PERFORM THESE TASKS FOR EACH WE LDED JOINT, BOLTED CONNECTION, OR STEEL ELEMENT. 5. NDT OF WELDS COMPLETED IN AN APPROVED FABRICATOR 'S SHOP MAY BE PERFORMED BY THAT FABRICATOR WHEN APPROVED BY THE A HJ. REFER TO AISC 360, N7. DEFINITIONS: 1. SPECIAL INSPECTION: INSPECTION OF CONSTRUCTION R EQUIRING THE EXPERTISE OF AN APPROVED SPECIAL INSPECTOR IN ORDER TO ENSURE COMPLIANCE WITH THE APPROVED CONSTRUCTION DOCUMENTS. 2. SPECIAL INSPECTOR: QUALIFIED FIRM OR INDIVIDUAL RESPONSIBLE FOR PERFORMING SPECIFIC TESTS OR INSPECTIONS AS PART OF THE SPECIAL INSPECTION PROGRAM. 3. PERIODIC SPECIAL INSPECTION: THE PART TIME OR IN TERMITTENT OBSERVATION OF WORK REQUIRING SPECIAL INSPECTION BY AN APPROVED SPECIAL INSPECTOR WHO IS PRESENT IN THE AREA WHERE THE WORK HAS BEEN OR IS BEING PERFORMED AND AT THE COMPLETION OF THE WORK. MAY BE ALLOWED WHEN COMPLIANCE OF THE WORK OR PRODUCT CAN BE DETERMINED AFTER BEING INCORPORATED INTO THE STRUCTURE. 4. CONTINUOUS SPECIAL INSPECTION: THE FULL TIME OBS ERVATION OF WORK REQUIRING SPECIAL INSPECTION BY AN APPROVED SPECIAL INSPECTOR WHO IS PRESENT IN THE AREA WHERE THE WORK IS BEING PERFORM ED. PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY: APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSIO N OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.10/8/2020 8:23:19 AMSCHEDULE OF SPECIAL INSPECTIONS 2020020.47 FINAL DRAWINGS 07/10/20 Author Approver TYPE B REMODEL S0.03MAVERIK, INC.3202 W. USTICK RD.MERIDIAN, ID 83646MAVERIK C-STORE #405GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 10/09/20 H 3 2 1 EDCA F.V. 98' - 11" +/- F.V. 8' - 10" +/- F.V. 8' - 0" +/- F.V. 15' - 7 1/2" +/- F.V. 18' - 6" +/- F.V. 13' - 10" +/- F.V. 18' - 6" +/- F.V. 15' - 7 1/2" +/-F.V.1' - 10" +/-F.V.8' - 2" +/-F.V.24' - 0" +/-F.V.15' - 11 1/4" +/-1 B F 2.1 2.2 EX. 36LHEX. 36LHEX. 36LHEX. 36LHEX. 36LHEX. 36LHEX. 36LHEX. 36LHEX. 36LHEX. 18KEX. 18KEX. W16x26 EX. W14x22 EX. W16x26 EX. W8x10F.V.49' - 11 1/4" +/-2 3 3 3 WT: 325# WT: 130# 4 5 4 5 6 6 7 8 S5.10 1 F.V. 5' - 1 1/2" +/- F.V. 5' - 1 1/2" +/- F.V. 6' - 9 5/8" +/- F.V. 6' - 4" +/- F.V. 6' - 9 5/8" +/- F.V. 6' - 9 5/8" +/- F.V. 6' - 4" +/- F.V. 6' - 9 5/8" +/- F.V. 6' - 9 5/8" +/- F.V. 6' - 4" +/- F.V. 6' - 9 5/8" +/- F.V. 6' - 9 7/8" +/- F.V. 6' - 9 5/8" +/- F.V. 6' - 5" +/- F.V. 4' - 5 1/2" +/- F.V. 4' - 4 1/4" +/- G EX. RTU EX. 36LHEX. 36LHEX. 36LHEX. 36LHEX. W8x10 3 1. THE CONTRACTOR SHALL VISIT THE SITE AND BECOME F AMILIAR WITH THE JOB CONDITIONS AND RESTRICTIONS. 2. EXISTING ROOF CONSTRUCTION, JOISTS, & JOIST SPAC ING IS BASED ON EXISTING STRUCTURAL DRAWINGS BY WCA PROJECT #: 13165, DATED 11/18/2013. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND ALL EXISTING CONSTRUCTION CONDITIONS PRIOR TO ORDERING MATERIALS AND COORDINATE ANY DISC REPANCIES WITH THE E.O.R. 3. VERIFY ALL ROOF OPENING SIZES AND LOCATIONS FOR MECHANICAL EQUIPMENT WITH ARCHITECTURAL AND MECHANICAL DRAWINGS. 4. DO NOT SCALE DRAWINGS. 5. GENERAL CONTRACTOR AND SUB-CONTRACTORS SHALL CAR EFULLY REVIEW THE CONSTRUCTION DOCUMENTS. INFORMATION REGARDING THE COMPLETE WORK IS DISPERSED THROUGHOUT THE DOCUMENT SET AND CANNOT BE ACCURATELY DETERMINED WITHOUT REFERENCE TO THE COMPLETE DOCUME NT SET. 6. FOR DIMENSIONS NOT SHOWN, SEE ARCHITECTURAL DRAW INGS. 7. SEE SHEETS S0.01 AND S0.02 FOR GENERAL STRUCTURA L NOTES. 8. SEE MECHANICAL DRAWINGS FOR SIZES AND LOCATIONS FOR ALL MECHANICAL EQUIPMENT. INDICATES METAL ROOF DECK PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY: APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSIO N OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.10/8/2020 8:23:19 AMPARTIAL ROOF FRAMING PLAN 2020020.47 FINAL DRAWINGS 07/10/20 Author Approver TYPE B REMODEL S1.11MAVERIK, INC.3202 W. USTICK RD.MERIDIAN, ID 83646MAVERIK C-STORE #405SCALE:1/4" = 1'-0"1 PARTIAL ROOF FRAMING PLAN KEYED NOTES GENERAL NOTESSYMBOL LEGEND 1 EXISTING 1.5" METAL DECK 2 EXISTING LT. GAUGE EXTERIOR WALL. 3 EXISTING STEEL COLUMN. 4 MC6x15.3 LAID FLAT WITH FLANGES TURNED DOWN BETWEEN THE DECK FLUTES TO SUPPORT MECHANICAL UNIT CURB. EXTEND MC6 CHANNEL 6" MIN. PAST BEARING END. SEE DETAIL 7/S5.10. 5 C6x8.2 LAID FLAT BENEATH ROOF CURB. 6 NEW CONDENSER PER MECHANICAL. SEE 7/S5.10 FOR SUPPORT DETAILS. 7 NEW TV. SEE 2/S5.10 FOR TV SUPPORT DETAILS. SEE ARCH'L DRAWINGS FOR LOCATION. 8 WALL FRAMING BELOW. N GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 10/09/20 NOTE: ALL METAL STUDS ARE 3 5/8"x20 GAUGE (362S137-33) AT 16" O.C. ATTACH NEW TRACK TO SOFFIT w/(2)-#10 SCREWS @ 16" O.C. SOFFIT FRAMING EX. METAL DECK PER PLAN (2)-#10 STS L3x3x1/4 BETWEEN HEADERS STEEL ANGLE, SEE PLAN. L3x3x1/4 BETWEEN JOISTS @ MAX 8'-0" O.C. 3/16 TYP. EA. END EX. STEEL JOIST PER PLAN 3/16 MC12 (3) SIDES OF CANOPY 362S137 -33 @ 16" O.C. 362T137-33 @ 16" O.C. w/(1)-# 10 SCREW AT EACH LEG BRIDGING CENTERED ON STUD LB362 STIFF CLIP WITH (3)-#12 STS INTO STUD AND (2) 3/16" DIA. P.A.F. INTO ANGLE SEE PLAN 3/16 3-12 CONT. L3x3x1/4 2"x2"x16 GAUGE CLIP AT EA. STUD TO ANGLE w/(2)-#10 SCREWS EA. LEG. 3/16 4 S5.10 MC12x10.6 (T/STL=10'-0") HSS3 1/2x3 1/2x5/16 HANGER 5 S5.10 HSS3 1/2x3 1/2x5/16 HANGER CENTERLINE HANGER/CHANNEL16' - 3"EQEQEQEQMC12x10.6 (T/STL=10'-0")MC12x10.6 (T/STL = 10'-0")L2x2x1/4 AT QUARTER POINTS w/(2) #10 STS SCREWS TO STUDS ROOF JOIST ABOVEROOF JOIST ABOVEROOF JOIST ABOVEEXISTING SOFFIT L3x3 (HIGH) BETWEEN JOIST TOP CHORD, TYP. L5x3x3/8 LLV (AT BOT. CHORD) L5x3x3/8 LLV (AT BOT. CHORD) L5x3x3/8 LLV (AT BOT. CHORD) L3x3 (LOW) BETWEEN JOIST TOP CHORD, TYP. L3x3 HEADER ANGLE (HIGH) L3x3 HEADER ANGLE (HIGH) 3' - 4" F.V. 4' - 6 5/8" +/- 3/8" STEEL PLATE WITH 1 1/2" RADIUS CORNERS, EACH END 3/8" DIA. ROD STEEL HANGER, SEE PLAN 3/16 3-12 3/16 3-12 1/4 1/4 L3x3x1/4 BETWEEN JOISTS PROVIDE JOIST REINFORCING PER DETAIL 6/S5.10 WHERE HANGER IS LOCATED BETWEEN PANEL POINTS EX. METAL DECK PER PLAN EX. STEEL JOIST PER PLAN #2 CLEVIS, EACH END 3/16 CHANNEL TO TUBE SEE PLAN MC12 (3) SIDES OF CANOPY SHEAR TAB (TYP.) SEE 3/S5.10 3/16 3/16 TYP. EA. END L5x3 (LLV) SEE PLAN 5" CONCRETE SLAB ON GRADE WITH #4 BARS @ 18" O.C. EACH WAY ON 10 MIL VAPOR RETARDER ON 8" COMPACTED #57 STONE. PROVIDE MIN. 6" LAP w/EX. VAPOR RETARDER. TAPE SEAMS SAW CUT LINEEX. CONC. SLAB NEW SLAB TO BE LEVEL AND FLUSH WITH ADJACENT SLAB #4x0'-8" DOWEL @ 12" O.C. w/HILTI HIT-HY 200 SAFESET ADHESIVE (4" EMBED.) UTILITY TRENCH SHEAR TAB SHALL BE 3/8" THICK. 5/16" FILLET WELD EACH SIDE OF SHEAR TAB. BOLT SPACING SHALL BE 3" TYP. HSS COLUMN SHALL HAVE A MINIMUM 1/4" THICKNESS. USE A SINGLE ANGLE CONNECTION WHERE STEEL TUBE WALL IS TOO THIN. BOLT EDGE DISTANCE, SHALL BE EQUAL TO TWICE THE BOLT DIAMETER FOR BOTH THE PLATE AND THE BEAM WEB. BOLT EDGE DISTANCE, SHALL BE 1-1/4" FOR BOLT DIAMETERS 7/8" OR LESS AND 1-3/4" FOR BOLT DIAMETERS GREATER THAN 7/8". ANGLE SIZE SHALL BE 3" FOR SHORT LEG AND 4 TIMES THE BOLT DIAMETER +1" FOR THE LONG LEG. "a" "b" "c" "e" "f" "g" A325 BOLT SCHEDULE MAXIMUM BEAM SIZE IN EACH BEAM DEPTH GROUP A-325N BOLTS No. PER BEAM SIZE MC12 3 3/4" DIA. 3" TRIM LEG IF WIDER THAN COLUMN STEEL COLUMN ANGLE "g" SEE NOTE "a" FOR THICKNESS 5/16 OR 5/16 3/4 5/16 SINGLE ANGLE CONNECTION WHERE REQUIRED BY NOTE "e" STEEL BEAM STEEL COLUMN SEE NOTE "e" TYP. 3/4" SHEAR TAB "a" "b" TYP.TYP."f"TYP."c""f" "f" NOTE: THIS DETAIL IS INTENDED TO BE USED WHERE LOADS OCCU R AT LOCATIONS OTHER THAN AT JOIST CHORD PANEL POINT LOC ATIONS. NOTE: WHEN A CONCENTRATED LOAD OCCURS BETWEEN CHORD PANEL POINTS, PROVIDE ANGLE REINFORCEMENT AS SHOWN IF THE APPLIED LOAD EXCEEDS 100#. IF MULTIPLE CONCENTRATED LOADS OCCUR BETWEEN CHORD PANEL POINTS, THE SUM OF THE CONCENTR ATED LOADS SHALL NOT EXCEED 100# L2x2x1/4 ANGLE STRUT AT JOISTS - PROVIDE ONE ANGLE ON EACH SIDE OF JOIST LOAD 3/16 3 SIDES EA. END PANEL POINT LOAD L2x2x1/4 EA. SIDE STEEL SHIMS @ 2'-0" O.C. (NOT REQ'D IF TAPERED CURBS ARE PROVIDED) 3/16 3 SIDES EA. END NOTE: WHEN A CONCENTRATED LOAD OCCURS BETWEEN CHORD PANEL POINTS, PROVIDE ANGLE REINFORCEMENT AS SHOWN IF THE APPLIED LOAD EXCEEDS 100 LBS. IF MULTIPLE CONCENTRATED LOADS OCCUR BETWEEN CHORD PANEL POINTS, THE SUM OF THE CONCENTRATED LOADS SHALL NOT EXCEED 100 LBS. C6 ALIGN w/CURB 1/4 MECH. UNIT MECH. UNIT CURB SEE MECH'L DWGS CONT. MC6 12 GAUGE STRAP w/(3)-# 12 SCREWS EA. END 1/2" DIA. SMOOTH DOWEL 18" LONG AT 12" O.C. - APPLY BOND BREAKER OR VISQUEEN WRAP TO FREE END CONSTRUCTION JOINT CONTROL JOINT VAPOR RETARDERCONC. SLAB, SEE PLAN CLEAN HARDENED CONCRETE AND APPLY BOND BREAKER PRIOR TO PLACING 2ND POUR 1/8" SAWCUT CONTROL JOINT TO BE 1/4 SLAB THICKNESS FILL SAW CUT w/JOINT SEALANT CONC. SLAB, SEE PLAN VAPOR RETARDER GRANULAR FILL (2)-#4 x 4'-0" LG. BARS WHERE CONTROL/CONSTRUCTION JOINTS INTERSECT BUT DO NOT CONTINIUE BEYOND INTERSECTION CONTROL OR CONSTRUCTION JOINT CONTROL OR CONSTRUCTION JOINTS (2)-#4 x 4'-0" LG. BARS AT EACH CORNER OF DEPRESSED SLAB OR RE-ENTRANT CORNER WHERE CONTROL/CONSTRUCTION JOINTS DO NOT EXTEND FROM CORNER DEPRESSED CONCRETE SLAB OR RE-ENTRANT CORNER METAL ROOF DECK EXISTING JOIST HSS4x4x3/16 WITH 1/8" CLOSURE PLATE EA. END 1/4 4'-0" MAX.HOUSING BOX(2)L3x3x1/4x0'-3" WITH 3/4" DIA. THREADED ROD AT EACH END, BOLTED TO THE JOIST BOTTOM CHORD 3/4" DIA. HOLE THROUGH TOP AND BOTTOM OF HSS FOR ELECTRICAL ACCESS 3" DIA. STD PIPE MITER TUBE AT TOP AS REQUIRED FOR ROOF SLOPE CENTER ON TUBE ABV A A SECTION A-A 1/4 TYP. 3 SIDES WHERE TUBE FALLS BETWEEN PANEL POINTS INSTALL JOIST REINFORCING PER DETAIL 6/S5.10 JOIST BOTTOM CHORD PLATE WASHER PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY: APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSIO N OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.10/8/2020 8:23:24 AMFOUNDATION & FRAMING DETAILS 2020020.47 FINAL DRAWINGS 07/10/20 Author Approver TYPE B REMODEL S5.10MAVERIK, INC.3202 W. USTICK RD.MERIDIAN, ID 83646MAVERIK C-STORE #405SCALE:3/4" = 1'-0"4 SECTION SCALE:1/4" = 1'-0"1 BON-FIRE GRILL CANOPY PLAN SCALE:3/4" = 1'-0"5 SECTION SCALE:3/4" = 1'-0"10 SECTION SCALE:3/4" = 1'-0"3 TYP. BOLTED SHEAR TAB CONN. SCHEDULE SCALE:3/4" = 1'-0"6 TYP. JOIST REINFORCING SCALE:3/4" = 1'-0"7 MECHANICAL ROOFTOP EQUIPMENT SUPPORT DETAIL SCALE:3/4" = 1'-0"8 TYP. FLOOR SLAB JOINT DETAILS SCALE:3/4" = 1'-0"9 TYP. RE-ENTRANT CORNER BAR DETAIL SCALE:3/4" = 1'-0"2 TYP. TV MOUNT DETAIL N GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 10/09/20 PLUMBING GENERAL NOTES 1. SLOPE BUILDING SANITARY WASTE LINES IN THE BUILDING AT 1/4”PER FOOT. THE P.C. MAY RUN 4”AND LARGER AT 1/8”PER FOOT IF PERMITTED BY THE AUTHORITY HAVING JURISDICTION. FIELD VERIFY EXTERIOR BUILDING SEWER INVERT PRIOR TO INSTALLATION OF INTERIOR PIPING. 2. PROVIDE WALL & FLOOR CLEANOUTS PER CODE REQUIREMENTS WITH (WALL) S.S. OR BRASS C.O. WALL COVERS, BRASS SCREWS, AND FLUSH WITH FINISHED WALL. SEE DETAIL 3/P2.02. 3. HANG ALL VENT PIPING AS SHOWN, WITH CLEVIS HANGERS, ALL THREAD ROD AND SIDE BEAM ATTACHMENTS OR EPOXY COATED UNISTRUT CHANNEL WITH CLAMPS. KEEP PIPING AS TIGHT AS POSSIBLE TO THE TRUSSES TO ENSURE NO OBSTRUCTIONS WITH OTHER TRADES, AND RAIN WATER LEADER/ROOF DRAIN PIPING. 4. PROVIDE DEEP SEAL P-TRAP AND TRAP PRIMER OR TRAP GUARD ON ALL FLOOR DRAINS/SINKS. TRAP SEAL DEVICE: J.R. SMITH 2692 OR PROSET TRAP GUARDS. INSTALL 1/2”SOFT “K”COPPER OR ENGLES METHOD PEX PIPE, ENCASED IN PLASTIC PIPE SLEEVE, TO EACH FLOOR DRAIN/SINK. TRAP SEAL DEVICES: NO PIPING REQUIRED. SEE DETAIL. 5. ALL FLOOR DRAINS/SINKS SHALL HAVE INDIVIDUAL P-TRAP AND SHALL BE VENTED BY THE BUILDING SANITARY VENT SYSTEM. 6. SEE CONVENIENCE STORE EQUIPMENT SCHEDULE ON SHEET P2.00 FOR KITCHEN EQUIPMENT INDIRECT WASTE REQUIREMENTS. PLUMBING CONTRACTOR SHALL ROUTE ALL KITCHEN EQUIPMENT, ICE BINS, AND OTHER EQUIPMENT INDIRECT WASTE LINES WITH AIR GAP TO NEAREST FLOOR SINK. COORDINATE ALL KITCHEN EQUIPMENT DRAINS WITH K.E. SUPPLIER AND INSTALLER. 7. ALL ICE MAKER AND ICE STORAGE BINS DRAIN LINES SHALL BE A MINIMUM OF 3/4”. NO EXCEPTIONS. 8. THE PLUMBING CONTRACTOR SHALL PROVIDE A FULL SIZE DRAIN ON ALL BACKFLOW PREVENTION DEVICES. ROUTE FULL SIZE DRAIN TO AN APPROVED DISCHARGE RECEPTOR, AND INSTALL WITH CODE COMPLIANT AIR GAP. 9. THE PLUMBING CONTRACTOR SHALL COORDINATE THE INSTALLATION OF ALL FLOOR DRAIN, FLOOR SINKS, AND TRAP PRIMERS. SEE ARCHITECTURAL SHEETS FOR DIMENSIONS AND EXACT LOCATIONS. CONTRACTOR SHALL CONTACT THE ARCHITECT IMMEDIATELY IF DISCREPANCIES EXIST. 10. CONNECT SEWER VENT PIPING AND ROUTE HORIZONTALLY WITHIN BUILDING. PENETRATE BUILDING WITH FULL SIZE VENT THROUGH ROOF WHERE SHOWN. INSTALL VTRS HEIGHT OF BUILDING PARAPET. SECURE ALL VENT PIPING. 11. HANG ALL VENT PIPING, AS SHOWN, WITH CLEVIS HANGERS, ALL THREADED ROD AND SIDE BEAM ATTACHMENTS OR EPOXY COATED UNISTRUT CHANNEL WITH CLAMPS. KEEP PIPING AS TIGHT AS POSSIBLE TO THE TRUSSES TO PROVIDE ROOM FOR OTHER TRADES, ROOF DRAINS AND STORM DRAIN PIPING. 12. PLUMBING CONTRACTOR SHALL PROVIDE PIPE TAG WITH EQUIPMENT NAME, FUNCTION AND BTUH LOAD. 13. PROVIDE TRUE-BRO INSULATION ITS, ON ALL SINKS WITH EXPOSED DRAINS AND SHUTOFF VALVES. 14. SEE THE KITCHEN EQUIPMENT SHEETS FOR REQUIREMENTS AND INSTALLATION HEIGHTS. EQUIPMENT IS OWNER FURNISHED, VENDOR INSTALLED. PLUMBING CONTRACTOR SHALL PROVIDE AND CONNECT WASTE, VENT AND WATER CONNECTIONS AND ALL ASSOCIATED MATERIALS. 15. MINIMUM CONDENSATE PIPING IS 3/4”. SEE PIPE SPECIFICATIONS FOR MATERIALS. 16. INDIRECT WASTE TO SINKS MAY BE PVC-DWV IF PERMITTED BY LOCAL CODE AND THE WATER SUPPLY TEMPERATURE TO SINKS IS 120°F OR LESS. IF WATER SUPPLY TEMPERATURE IS GREATER THAN 120°F, USE HARD DRAWN 'L' COPPER PIPE WITH WROUGHT FITTINGS. 17. ALL FLOOR DRAINS SHALL BE FLUSH WITH FINISHED FLOOR. 18. CABINETS CONTAINING FLOOR SINK SHALL BE OPEN TO THE FLOOR SINK FOR CLEANING AND ACCESS. 19. MAINTAIN CODE COMPLIANT SEPARATION BETWEEN SANITARY WASTES AND FOOD SERVICE WASTES. 20. ALL VENTS IN EXTERIOR WALLS SHALL BE INSTALLED ON THE WARM SIDE OF BUILDING INSULATION. 21. ALL UNDER FLOOR WATER PIPING SHALL BE WRAPPED IN MINIMUM OF 1/2”THICK ARMAFLEX INSULATION, OR AS REQUIRED PER LOCAL CODE, UNLESS PIPING IS LOCATED WITHIN A PIPE CHASE OR UNDERSLAB SLEEVE. 22. SEE PLUMBING PLANS FOR EXACT LOCATION OF ROOF DRAINS AND VENT PIPING THROUGH ROOF. 23. ALL GAS PIPING SHALL BE INSTALLED IN COMPLIANCE WITH ALL LOCAL CODES AND NFPA REQUIREMENTS. PROVIDE PERMITS, MATERIALS AND LABOR FOR A COMPLETE, FUNCTIONAL PIPING SYSTEM. PERFORM ALL TESTS TO MEET THESE CODES. 24. PLUMBING CONTRACTOR SHALL CONFIRM LOCATION OF ALL EQUIPMENT PRIOR TO PROVIDING PLUMBING ROUGH-IN. 25. ANY PENETRATIONS THROUGH FIRE RATED PARTITIONS SHALL BE SEALED WITH SCOTCH-3M #FS 195 WRAP AND CP #25 CAULK. 26. PLUMBING CONTRACTOR SHALL NOT INSTALL PIPING ABOVE OR WITHIN THE CODE REQUIRED WORKING CLEARANCES OF AN ELECTRICAL PANEL, SWITCH GEAR, OR CONDUITS. COORDINATE ALL WORK WITH THE ELECTRICAL CONTRACTOR. 27. THE PLUMBING CONTRACTOR SHALL MAKE ALL REQUIRED FINAL PLUMBING CONNECTIONS TO OWNER SUPPLIED EQUIPMENT. 28. VENTS OFFSETTING HORIZONTALLY MUST BE AT LEAST 6”ABOVE THE HIGHEST FIXTURE’S FLOOD RIM. 29. THE PLUMBING CONTRACTOR SHALL PROVIDE AND INSTALL ALL ‘P’PLUMBING FIXTURES AND EQUIPMENT SHOWN ON THE PLUMBING FIXTURE SCHEDULE. OWNER FURNISHED ITEMS SHALL BE CONNECTED TO BUILDING WASTE AND WATER SYSTEMS BY THE PLUMBING CONTRACTOR. 30. ONLY FULL PORT BALL VALVES ARE PERMITTED AND SHALL BE USED FOR ZONE OR AREA VALVES WITHIN THE BUILDING. 37. ALL HOT WATER, COLD WATER, ROOF DRAIN, OVERFLOW DRAIN, AND CONDENSATE PIPING WILL BE INSULATED WITH MINIMUM 1”THICK INSULATION. SEE INSULATION SCHEDULE IN THESE PLANS FOR INSULATION TYPE AND THICKNESS. 38. ALL WATER LINES SHALL BE HUNG USING COATED CLEVIS HANGERS, ALL THREAD ROD AND SIDE BEAM ATTACHMENTS OR EPOXY COATED UNISTRUT CHANNEL, ALL THREAD ROD AND SIDE BEAM ATTACHMENTS, SECURE PIPE WITH INSULATED CLAMPS. 39. ALL KITCHEN EQUIPMENT, OWNER PROVIDED EQUIPMENT, AND BAR SINKS INDIRECT WASTE DRAINS SHALL BE PIPED TO A FLOOR SINK W/PROPER AIR GAP. PROVIDE CLEAN OUT ACCESS TO THESE FLOOR SINKS LOCATED UNDER CABINETS. 40. INSTALL WATER BALL VALVE SHUT OFF VALVES TO ALL OWNER PROVIDED KITCHEN AND BEVERAGE EQUIPMENT. VALVES SHALL BE PARKER HANNIFIN, APOLLO FERGUSON OR NIBCO. MAY BE SUBSTITUTED WITH 10-DAY PRIOR APPROVAL BY OWNER AND ENGINEER. THESE VALVES SHALL BE LOCATED PER EQUIPMENT MANUFACTURERS RECOMMENDATION OR OWNERS DIRECTION. PROVIDE AND INSTALL ALL BACKFLOW PREVENTION AS REQUIRED PER STATE AND LOCAL PLUMBING CODES. 41. SEE SHEET P2.00, PLUMBING FIXTURE SCHEDULE FOR A LISTING OF ALL OF THE PLUMBING FIXTURES AND EACH FIXTURE’S TRIM. 42. ANY & ALL PENETRATIONS THROUGH THE BUILDING ROOF OR WALLS SHALL BE SEALED WITH “DECK-MATE”FLASHING FOR ROOF & WALL SYSTEMS. G.C. SHALL PROVIDE, INSTALL & PAINT TO MATCH BUILDING. PLUMBING CONTRACTOR SHALL COORDINATE WITH THE G.C. ALL PENETRATIONS AND SIZES. THE ARCHITECT SHALL HAVE THE FINAL INPUT ON HOW ALL PENETRATIONS SHALL BE SEALED. THE PLUMBING CONTRACTOR AND G.C. SHALL VERIFY WITH THE ARCHITECT ALL SEALING REQUIREMENTS. 43. THE PLUMBING CONTRACTOR SHALL PROVIDE A PERMANENTLY SECURED LAMINATED VALVE TAG (PRIOR TO FINAL WALK THRU), TO EACH OF THE COLD AND HOT WATER VALVES WHICH SERVE THE MAVERIK’S EQUIPMENT. 44. ALL WATER VALVES ABOVE HARD LID OR DROP-IN CEILING SHALL BE INSTALLED BETWEEN 1’-0”TO 1’-6”ABOVE THE CEILING FOR ACCESS VIA LADDER BY MAINTENANCE PERSONNEL. PROVIDE BIG ENOUGH ACCESS PANEL TO ACCESS EACH VALVE AT EACH LOCATION. 45. THE PLUMBING CONTRACTOR SHALL MEET ALL STATE, LOCAL AND HEALTH DEPARTMENT CODES RELATED TO BACKFLOW PROTECTION. EACH PIECE OF EQUIPMENT THAT IS PROVIDED BY THE P.C. AND THE OWNER SHALL HAVE THE PROPER BACKFLOW PREVENTION. FIELD VERIFY WITH STATE, CITY AND HEALTH DEPARTMENT BACKFLOW PROTECTION REQUIREMENTS FOR THE STORE AND EACH PIECE OF EQUIPMENT BEING INSTALLED. THE P.C. IS RESPONSIBLE TO PROVIDE ALL NECESSARY BACKFLOW PREVENTION DEVICES FOR EACH EQUIPMENT PIECE. PROVIDE FULL SIZE DRAINS TO AN APPROVED RECEPTOR WITH CODE COMPLIANT AIR GAP. PLUMBING GENERAL NOTES PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY: APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.10/9/2020 11:17:42 AMPLUMBING LEGENDS & NOTES 2020020.47 FINAL DRAWINGS 07/10/20 Author Approver TYPE B REMODEL P0.00MAVERIK, INC.3202 W. USTICK RD.MERIDIAN, ID 83646MAVERIK C-STORE #405NG(LP) LOW PRESSURE NATURAL GA... HB HOSE BIBB FPSC FROSTPROOF SILLCOCK AD ACCESS DOOR AFF ABOVE FINISHED FLOOR HD HUB DRAIN BFP BACKFLOW PREVENTER KEC KITCHEN EQUIPMENT... FS FLOOR SINK VTR VENT THRU ROOF SH SHOWER FD FLOOR DRAIN CO CLEANOUT COTG CLEANOUT TO GRADE FCO FLUSH WITH FLOOR CLEANOUT EWC ELECTRIC WATER COOLER MS MOP SINK S SINK LAV LAVATORY UR URINAL WC WATER CLOSET CD CONDENSATE DRAIN PIPING CA COMPRESSED AIR PIPNG FP FIRE PROTECTION PIPING NG NATURAL GAS PIPING HWR HOT WATER RETURN PIPING HW HOT WATER PIPING CW COLD WATER PIPING OFD OVERFLOW ROOF DRAIN... RD ROOF DRAIN PIPING V SANITARY VENT PIPING GW GREASE WASTE SAN SANITARY PIPING PLUMBING ABBREVIATIONS THIS PROJECT CONSISTS OF AN EXISTING CONVENIENCE STORE REFRESH OF STORE FIXTURES AND STORE EQUIPMENT. THERE WILL BE SEVERAL NEW WALLS INSTALLED TO FACILITATE THE REFRESH. THE EXISTING DRINK STATION AREA IS BEING RECONFIGURED. THE NEW DRINK EQUIPMENT WILL REQUIRE NEW INDIRECT WASTES TO THE NEW DRINK STATION FLOOR SINK. THE NEW DUMP SINK WILL HAVE AN INDIRECT WASTE DRAINING TO THE NEW FLOOR SINK, AND IT WILL CONNECT TO ADJACENT HOT AND COLD WATER BRANCHES. THERE ARE NEW DUMP SINKS LOCATED ON A NEW WALL, THEY WILL INDIRECTLY WASTE INTO A NEW FLOOR SINK AND THEY WILL CONNECT TO EXISTING ADJACENT HOT AND COLD WATER BRANCHES. THE EXISTING COFFEE AREA WILL BE SHORTENED, WITH AN EXISTING WING WALL REMOVED. THERE WILL BE NEW CABINETRY, COUNTER AND NEW EQUIPMENT. COFFEE AREA PLUMBING WILL BE MODIFIED TO ACCOMMODATE THE NEW LAYOUT, AND NEW FLOOR SINKS AND DUMP SINK WILL BE INSTALLED. CONTRACTOR WILL PROVIDE NEW CONNECTIONS TO EXISTING WATER, WASTE AND VENT BRANCH MAINS. THE RESTROOMS ARE BEING ENLARGED TO MAKE ROOM FOR AN ADDITIONAL WATER CLOSET OR URINAL. THE WASTE PIPING WILL BE MODIFIED TO CONNECT TO THE NEW FIXTURES. PLUMBING DESIGN INTENT GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 10/09/20 H 3 2 1 EDCAB F 2.1 2.2 G 4 4 (E)FS-1 (E)FS-1 (E)FS-1 7 7 4 4 4 3 9 9 9 9 (E)FS-1 (E) 4"ø GW(E) 4"ø GW (E)FS-1 8 (E)FS-1 7 7 8 4 (E)FS-1(E)FS-1 (E)FS-1 4 (E)FS-1 (E)FS-1 6 3 1 1 2 2 10 11 5 PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY: APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.10/9/2020 11:17:44 AMPLUMBING DEMOLITION PLAN 2020020.47 FINAL DRAWINGS 07/10/20 Author Approver TYPE B REMODEL P0.01MAVERIK, INC.3202 W. USTICK RD.MERIDIAN, ID 83646MAVERIK C-STORE #405KEY NOTES SCALE:1/4" = 1'-0"1 PLUMBING DEMOLITION PLAN 10 EXISTING SANITARY WASTE TO REMAIN. JET AND SCOPE ALL EXISTING PIPING BEING MODIFIED TO ENSURE NO OBSTRUCTIONS. NOTIFY OWNER IF DAMAGED OR OBSTRUCTED. 11 REMOVE EXISTING SANITARY WASTE UPSTREAM OF THE CONNECTION TO THE RESTROOM FLOOR DRAINS. PREPARE REMAINING PIPE FOR CONNECTION TO NEW PIPING. 1 REMOVE AND STORE EXISTING URINALS AND WATER CLOSETS FOR REINSTALLATION AFTER NEW RESTROOM FINISHES INSTALLED. 2 REMOVE EXISTING LAVATORY. 3 EXISTING FLOOR SINK TO REMAIN. RETAIN SANITARY VENT CONNECTIONS. 4 EXISTING FLOOR SINK TO BE REMOVED. CUT AND CAP WASTE AND VENT BELOW FLOOR. 5 REMOVE WASTE PIPING SERVING EXISTING URINAL FROM VENT CONNECTION TO MAIN AND PREPARE FOR THE INSTALLATION OF NEW WASTE AND VENT PIPING. REMOVE THE WATER LINE SERVING THE EXISTING URINAL BACK TO THE MAIN AND CAP. 6 RETAIN EXISTING BEVERAGE CONDUIT. 7 CUT AND CAP EXISTING BEVERAGE CONDUIT BELOW FLOOR. 8 RETAIN CONDUIT. SEE P1.01 FOR CONTUNUATION. 9 EXISTING GREASE WASTE TO REMAIN. JET AND SCOPE ALL EXISTING PIPING BEING MODIFIED TO ENSURE NO OBSTRUCTIONS. NOTIFY OWNER IF DAMAGED OR OBSTRUCTED. N GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 10/09/20 H 3 2 1 EDCAB F 2.1 2.2 2 51 51 110 51 1 2 2 3 72.1 72.1 N49 13 6 66 6 P7 P7 P7 P7 7 7 7 7 8 8 N106 N69 14 16 7 7 95 964 8 8 8 2 8 P5 P5 G 3"ø GW FS-1 FS-1 FS-1 FS-1 2 6 48 9C 9C N9 N9 11 N9 FS-1 (E)FS-1 51 4 49 5 (E) 4"ø SAN2"ø SAN1 1/2"ø V(E) 2"ø V (E) 2"ø V(E) 4"ø SAN4 PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY: APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.10/9/2020 11:17:47 AMPLUMBING WASTE AND VENT PLAN 2020020.47 FINAL DRAWINGS 07/10/20 Author Approver TYPE B REMODEL P1.01MAVERIK, INC.3202 W. USTICK RD.MERIDIAN, ID 83646MAVERIK C-STORE #405SCALE:1/4" = 1'-0"1 PLUMBING WASTE AND VENT PLAN KEY NOTES 7 EXISTING GREASE WASTE TO REMAIN. JET AND SCOPE ALL EXISTING PIPING BEING MODIFIED TO ENSURE NO OBSTRUCTIONS. NOTIFY OWNER IF DAMAGED OR OBSTRUCTED. 8 TIE NEW VENT INTO EXISTING VENT MAIN. FIELD VERIFY EXACT LOCATION AND HEIGHT OF EXISTING VENT MAIN PRIOR TO THE START OF ANY WORK. 9 CONNECT NEW SANITARY WASTE PIPING TO EXISTING PIPING. 1 EXTEND 4" PVC CONDUIT TO NEW GONDOLA. COORDINATE WITH ARCHITECTURAL FOR PENETRATION. 2 CONNECT NEW 3" FS-1 TO EXISTING 3" MINIMUM GREASE WASTE MAIN. ROUTE 1-1/2" VENT UP AND CONNECT TO EXISTING VENT. 3 CONTRACTOR SHALL REWORK EXISTING SODA CONDUIT SO IT IS ENCLOSED WITHIN NEW CABINETRY. COORDINATE WITH EXISTING CONDITIONS. 4 REINSTALL EXISTING URNIALS AND WATER CLOSETS AFTER NEW TILE INSTALLATION. 5 EXISTING SANITARY WASTE TO REMAIN. JET AND SCOPE ALL EXISTING PIPING BEING MODIFIED TO ENSURE NO OBSTRUCTIONS. NOTIFY OWNER IF DAMAGED OR OBSTRUCTED. 6 ROUTE 1-1/2" INDIRECT WASTE FROM DUMP SINK TO FLOOR SINK BELOW. SEE INDIRECT WASTE PIPING DETAILS FOR ADDITIONAL INFROMATION. N GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 10/09/20 H 3 2 1 EDCA 1 2 3 4 5 7 8 B F 2.1 2.2 P7 2 1821 72.1 72.1 9695 N102 51 5151 3 36 P7 P7 P7 8 8 15 P5 P5 G 9 9C 9C 11 N9 N9 48 7 7 8 (E) 1"ø CW (E) 1"ø CW (E) 1"ø CW (E) 1 1/2"ø CW 11 11 10 10 P3 P2 P2 P2 11 PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY: APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.10/9/2020 11:17:50 AMPLUMBING WATER PLAN 2020020.47 FINAL DRAWINGS 07/10/20 Author Approver TYPE B REMODEL P1.02MAVERIK, INC.3202 W. USTICK RD.MERIDIAN, ID 83646MAVERIK C-STORE #405SCALE:1/4" = 1'-0"1 PLUMBING WATER PLAN KEY NOTES 1 CONNECT TO EXISTING 1/2" FILTERED WATER FW-2. ROUTE LINE TO CAPPUCCINO MACHINE. PROVIDE CODE COMPLIANT BACKFLOW PREVENTER AS SCHEDULED ON SHEET P2.00. 2 CONNECT TO EXISTING 1/2" FILTERED WATER FW-1. ROUTE LINE TO COFFEE MAKER. PROVIDE CODE COMPLIANT BACKFLOW PREVENTOR AS SCHEDULED ON SHEET P2.00 3 CONNECT 1/2" HW & 1/2" CW TO SINK PROVIDE WITH ISOLATION SHUTOFF VALVES LOCATED ABOVE FIXTURE, IN CEILING ABOVE. 4 RETAIN EXISTING 4" UNDERGROUND PVC CONDUIT AND WATER LINES. 5 PROVIDE NEW 1/2" CW, 1/2" HW, 1/2" FW-1, & 1/2" FW-2 WATER LINES IN EXTENDED CONDUIT. CONNECT NEW PIPING TO EXISTING BRANCH MAINS. 6 ROUTE NEW 3/4" FW-1 FROM FILTERS TO ICE MACHINES. PROVIDE CODE COMPLIANT BACKFLOW PREVENTER AS SCHEDULED ON SHEET P2.00 FOR EACH ICE MACHINE. 7 ROUTE NEW 3/4" FW-2 FROM FILTERS DOWN IN WALL. PROVIDE 1/2" BRANCH TO EACH FROZEN CARBONATED BEVERAGE MACHINE WITH CODE COMPLIANT BACKFLOW PREVENTER SCHEDULED ON SHEET P2.00. 8 ROUTE NEW 1/2" FW-1 DOWN IN WALL. ROUTE TO TEA BREWER, PROVIDE CODE COMPLIANT BACKFLOW PREVENTER AS SCHEDULED ON SHEET P2.00. 9 CONNECT TO EXISTING 1/2" FILTERED WATER FW-1. ROUTE LINE TO F'REAL MACHINE. PROVIDE CODE COMPLIANT BACKFLOW PREVENTER AS SCHEDULED ON SHEET P2.00. 10 PROVIDE NEW LAVATORY IN NEW LOCATION. CONNECT TO EXISTING HOT AND COLD WATER PIPING. MODIFY/EXTEND PIPING AS NEEDED TO COMPLETE THE INSTALLATION. 11 REINSTALL EXISTING URINALS AND WATER CLOSETS AFTER NEW TILE INSTALLATION. N GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 10/09/20 SYMBOL WDESCRIPTIONVCWHW PLUMBING FIXTURE SCHEDULE EQUIPMENT AND INSTALLATION BY PLUMBING CONTRACTOR UNLESS NOTED OTHERWISE P7 IW1/2" 1/2" 1 1/2" BAR SINK - THE SINKS TO BE FURNISHED AND INSTALLED BY THE MILL WORK CONTRACTOR. THE P.C. SHALL TRIM THESE SINKS OUT AND CONNECT THEM TO THE WATER AND SEWER SYSTEMS. PROVIDE AND INSTALL KOHLER K 15888/K 15850-4M-CP "CORALAIS" TWO HANDLE BAR FAUCET, KOHLER K 8807-3 1/2" SINK STRAINER, LEONARD MODEL 20300 THERMOSTATIC MIXING VALVE (SET THE OUTLET HOT WATER TEMPERATURE AT 105 TO 110 DEGREES), BRASSCRAFT KTCR19X C STOPS, ESCUTCHEONS, STAINLESSSTEEL BRAIDED SUPPLIES, AND 1 1/2" INDORECT WASTE TO FLOOR SINK. POSITION FAUCET AS SHOWN ON THE DRAWINGS. P9 3/4"___ WATER FILTER -OWNER FURNISHED, P.C. INSTALLED. P.C. TO FURNISH WATER LINES TO UNIT WITH SHUT OFF VALVE AND RUN FILTERED WATER (FW1) TO FIXURES OR KITCHEN EQUIPMENT SHOWN ON THE DRAWINGS. P12 P11 2" 2" ___ ___ BACKFLOW PREVENTER -WATTS LF009MSQT-S REDUCED PRESSURE BACKFLOW PREVENTER, IN-LINE CHECK VALVES, TEST COCKS, 2 SHUT OFF VALVES AND BRONZE STRAINER. PIPING DRAIN TO FLOOR SINK IN THIS ROOM. INSTALL 48”A.F.F. PRESSURE REDUCING VALVE -WATTS LFU5B, WITH BYPASS FOR THERMAL EXPANSION. SET REGULATOR FOR MINIMUM OF 55.5 PSI AT THE OUTLET, PROVIDE 0-200 PSI 2-1/2”FACE-PRESSURE GAUGE, AND BALL VALVES ON BOTH INLET & OUTLET ENDS OF RPZ. INSTALL AT 48”A.F.F. SEE DETAIL 15/P2.01. FS2 FS1 _3" _ _1 1/2"2" 1 1/2"_ FLOOR SINK -J.R. SMITH MODEL #3140Y02-PDBS, 12-1/2”X12-1/2”X6”, 2”OUTLET WITH POLISHED ALUMINUM DOME STRAINER. PROVIDE DEEP SEAL P-TRAPS WITH TRAP PRIMERS. IF APPROVED BY AUTHORITY HAVING JURISDICTION, P.C. MAY USE PROSET TRAP GUARDS IN LIEU OF TRAP PRIMERS. SEE DETAIL 3/P2.01. FLOOR SINK -J.R. SMITH MODEL #3140Y02-PDBS, 12-1/2”X12-1/2”X6”, 2”OUTLET WITH POLISHED ALUMINUM DOME STRAINER. PROVIDE DEEP SEAL P-TRAPS WITH TRAP PRIMERS. IF APPROVED BY AUTHORITY HAVING JURISDICTION, P.C. MAY USE PROSET TRAP GUARDS IN LIEU OF TRAP PRIMERS. SEE DETAIL 3/P2.01. P5 1 1/2" 2" 1/2"1/2" LAVATORY (ADA) - ELKAY "LUSTERTONE" LLVR1916-1, STAINLESS STEEL SINGLE BOWL 19 5/8" X 16 11/16", SINGLE FAUCET HOLE, FULLY UNDERCOATED, LKF293 OVERFLOW ASSEMBLY, SELF-RIMMING, OVAL LAVATORY. PROVIDE & INSTALL ELKAY LK174 BRASS GRID STRAINER W/OVERFLOW OPENING, TOTO SELF-GENERATING "ECOPOWER" SENSOR THERMAL MIXING FAUCET-MODEL TEL101-D10ET WITH STANDARD SPOUT WITH THERMOSTATIC MIXING VALVE (SET AT 110°F TO 115°F HOT WATER), TOTO TES1ADC-05 #CP SOAP DISENSER, TSFB1 SOAP, BRASSCRAFT KTCR19X C STOPS, ESCUTCHEONS, AND TRUE-BRO 102W ADA INSULATION KIT. MOUNT LAVATORY IN THE VANITY COUNTERTOP BY OWNER. P3 P1 P2 2"_4" _2"4" 3/4"2"3" 1" 1" _ WATER CLOSET (ADA)-KOHLER K-96057-0 "HIGHCLIFF", 12" ROUGH-IN, ELONGATED BOWL, 16 7/8" BOWL HEIGHT, 1-1/2" SPUD, 1.6PGF, SIPHON JET OPERATING SYSTEM, WHITE VITRIOUS CHINA WATER CLOSET. PROVIDE KOHLER K-4670-C WHITE SEAT W/OPEN FRONT AND SLOAN MODEL 8111-1.6/1.1 "SOLIS" 1.6 OR 1.1 GPF, SOLAR POWERED DUAL FLUSH FLUSHOMETER, TOILET FLUSH CONTROLS TO BE LOCATED ON THE OPEN SIDE OF THE WATER CLOSET. WATER CLOSET -KOHLER K-96053-0 "WELLCOMME", 12" ROUGH-IN, ELONGATED BOWL, 15 1/4" BOWL HEIGHT, 1-1/2" SPUD, 1.6PGF, SIPHON JET OPERATING SYSTEM, WHITE VITRIOUS CHINA WATER CLOSET. PROVIDE KOHLER K-4670-C WHITE SEAT W/OPEN FRONT AND SLOAN MODEL 8111-1.6/1.1 "SOLIS" 1.6 OR 1.1 GPF, SOLAR POWERED DUAL FLUSH FLUSHOMETER, TOILET FLUSH CONTROLS TO BE LOCATED ON THE OPEN SIDE OF THE WATER CLOSET. URINAL (ADA)-KOHLER K-4991 ET-0, "BARDON", WALL HUNG, WHITE VITREOUS CHINA, 3/4" TO SPUD, "WATERSENSE COMPLIANT", 1.0 GPF, HIGH EFFICIENCY URINAL, PROVIDE SLOAN MODEL 8186-1 "SOLIS" 1.0 GPF SOLAR POWERED FLUSHOMETER AND A J.R. SMITH 0636 "OFF THE FLOOR" URINAL SUPPORT. MOUNT URINAL 17" FROM FINISHED FLOOR TO RIM OF URINAL. NOTE: FOR PIPE SIZES 1 1/4" & SMALLER, USE INSULATION SIZED FOR A 1/4" LARGER PIPE TO ALLOW ROOM FOR INSULATION OVER HEAT TRACE CABLE. NOTE: ALL UNDERGROUND AIR, HOT & COLD WATER, HOT WATER RETURN & SUPPLY, REFRIGERANT, STEAM & CONENSATE PIPING TO BE INSULATED, ALSO SEE SPECIFICATIONS. INSULATION SCHEDULE (° F) 40° -180° 40° -180° FLUID TEMP. RANGE 100° -140° 35° -140°REFRIGERANT DOMESTIC HOT & COLD WATER ABOVE FLOOR DOMESTIC HOT & COLD WATER BELOW SLAB HEAT TRACED DOMESTIC HOT WATER ABOVE FLOOR SYSTEM TYPE 1/2" ARMAFLEX OR IMCOA 1/2" -1" 2" 1 1/4" -1 1/2" PIPE SIZES 1" 1 1/2" 2" FIBERGLASS INS. THICKNESS 1/2" ARMAFLEX OR IMCOA INSULATION TYPE DOMESTIC HOT WATER ABOVE FLOOR WITH HEAT TRACE DOMESTIC COLD WATER ABOVE FLOOR ALL 1" ROOF DRAIN & OVERFLOW DRAIN ABOVE FLOOR ALL 1" FIBERGLASS w/ VAPOR BARRIER 2 1/2"2 1/2" 3" OR LARGER SAME SIZE AS PIPE 1/2" -1" 2" OR LARGER 1 1/4" -2" 1" 1 1/2" 2" DOMESTIC HOT WATER ABOVE FLOOR WITHOUT HEAT TRACE DISHWASHER - ON HOT & COLD WATER LINES (WATTS # LF288A), ASSE 1001. WATTS # LF26A 0-25 PSI VALVE 3/4" LIQUID FILLED GAUGE 0-100 PS1. 3 COMPARTMENT SINK - FAUCETS W/ VACUUM BREAKERS WITH NO HOSE CONNECTION. FILTERED WATER SYSTEM (R.O.), SODA / CARBONATOR SYSTEM - WATTS # LFSD-3, ASSE 1022. COFFEE MACHINES CAPPACCINO MACHINES - WATTS # 9BD, ASSE 1052. PIPE DRAIN TO NEAREST FLOOR SINK, ASSE 1052. ICE MACHINES - WATTS # LF7U2-2 DUAL CHECK, ASSE 1024. R.O. FILTER SYSTEM - WATTS # LF007M1QT-S, ASSE 1015. PLUMBER PROVIDED & INSTALLED BACKFLOW PROTECTION & PRESSURE REDUCING CONVENIENCE STORE EQUIPMENT SCHEDULE EQUIPMENT SUPPLIED & SET BY SUPPLIER INDICATED ON FACILITIES EQUIPMENT DRAWINGS (EQ). ALL PLUMBING ROUGH-IN & FINAL PLUMBING CONNECTIONS BY PLUMBING CONTRACTOR. REFER TO EQ. DRAWINGS FOR EXACT ROUGH-IN, CONNECTION REQUIREMENTS LOCATIONS & DIMENSIONS. ALL HOT & COLD WATER CONNECTIONS TO EQUIPMENT SHALL BE MADE THRU VALVES OR STOPS EQUAL TO THOSE SPECIFIED FOR PLUMBING FIXTURES AND BRAIDED STAINLESS STEEL CONNECTORS. 2. WASTE & VENT, 3. CONDENSATE DRAINS: RAIN WATER BELOW GRADE: 1. DOMESTIC WATER:TYPE 'K' SOFT COPPER BELOW FLOOR OR GRADE w/ WROUGHT COPPER FITTINGS (BRAZED). TYPE 'L' HARD DRAWN COPPER TUBING w/ WROUGHT COPPER (95/5 SOLDER). FITTINGS ABOVE FLOOR OR GRADE. 3/4" -2 1/2" TYPE "K" SOFT COPPER 3" + DUCTILE IRON OR PVC CONFORMING TO AWWA STANDARDS SERVICE WEIGHT NO-HUB CAST IRON w/ MG' OR 'IDEAL' FITTINGS. SCHEDULE 40 GALV. STEEL FOR EXPOSED VENT LINES. ALL DRAINS & TRAPS TO BE CAST BRASS, CAST IRON OR GALV, STEEL. PLASTIC PIPING CONFORMING TO IAPMO AND ASTM SPECIFICATIONS IS ACCEPTABLE WHERE PERMITTED BY LOCAL CODES. NO PLASTIC PIPE IS PERMITTED IN RETURN PLENUM ATTIC. TYPE 'L' HARD DRAWN COPPER w/ WROUGHT COPPER SOLDER JOINT FITTINGS. WALK-IN COOLERS/FREEZERS: MINIMUM OF TYPE M COPPER PIPE WITH 95/5 SOLDER FITTING AND MEET NSF STANDARDS. NO COMBUSTIBLE PIPING OR MATERIAL SHALL BE RUN IN RETURN AIR PLENUM SPACE ABOVE CEILING. ALL UNDERGROUND WATER PIPING SHALL BE WRAPPED &/OR INSULATED PER SPECIFICATIONS. PIPE SPECIFICATIONS 1. DOMESTIC WATER: PEX PIPING MAY BE INSTALLED IN ALL CONCEALED SPACES, ABOVE CEILING, AND IN BETWEEN WALLS IF APPROVED BY THE LOCAL PLUMBING CODE. THE P.C. SHALL USE THE FOLLOWING: PEX PIPE:UPONOR -PAX a (ENGLE-METHOD CROSSLINKED POLYETHYLENE). ASTM 876/877. FITTINGS:UPONOR -PROPEX ENGINEERED POLYMER (EP) FITTINGS. ASTM 1960 AND ANSI/NSF 14 & ANSI/NSF 61. CONNECTORS:UPONOR -PROPEX RINGS (ENGLE-METHOD CROSSLONKED POLYETHYLENE). ANSI/NSF 14 & ANSI/NSF 61. SUPPORTS:UPONOR -PAX a PIPE SUPPORT (CHANNEL). GALVANIZED STEEL CHANNEL. FOR ASTME 84 INSTALLATIONS. ALL PIPE MUST BE COVERED WITH A PEX a PIPE SUPPORT OR A MINIMUM 1/2" THICK RATED INSULATION. REFER TO UPONOR INSTALLATION INSTRUCTIONS. "ALL EXPOSED PIPING SHALL BE TYPE "K" COPPER WITH WROUGHT FITTINGS." (NO SUBSTITUTIONS) : WRONG MATERIALS WILL BE REMOVED AND REPLACED AT THE PLUMBING CONTRACTORS EXPENSE. PEX PIPE ALTERNATE SPECIFICATIONS PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY: APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.10/9/2020 11:17:51 AMPLUMBING SCHEDULES 2020020.47 FINAL DRAWINGS 07/10/20 Author Approver TYPE B REMODEL P2.00MAVERIK, INC.3202 W. USTICK RD.MERIDIAN, ID 83646MAVERIK C-STORE #405_ ITEM DESCRIPTION MODEL/MFG. FW CW HW V W IW NOTES: 4 ICE/BEVERAGE DISPENSER FLAVOR SELECT/ FS60 3/8" - - - 3/4" TO FLOOR SINK 11 CAPPUCCINO MACHINE Bunn iMix-5S 1/4" - - - - TO FLOOR SINK 18 QUIETQUBE ICE MAKER HOSHIZAKI 3/8" - - - 3/4" TO FLOOR SINK 20A OVEN/RACK NU-VU-OP-4/8 M 1/4" - - - - - 21 ICE MAKER ( OVER BEV. DISP.) N13 22R-32 SCOTSMAN PRODIGY PLUS 3/8" - - - - TO FLOOR SINK 33 ICE CREAM MERCHANDISER ZERO ZONE - - - - - TO FLOOR SINK 51 STAINLESS STEEL SINK (HAND OR BAR) FURNISHED BY MILLWORK - 1/2" 1/2" 1-1/2" 2" TO FLOOR SINK 72.1 FROZEN CARBONATED BEV. ICEE-VIPER 4 FLAV.3/8" - - - 1/2" TO FLOOR SINK 96 F'REAL 11-CSGF-X1-FR RL 1/4" - - - 3/4" TO FLOOR SINK GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 10/09/20 UNION COOLING COIL PIPING SUPPORTS AT 5' O.C. AND AT CHANGES IN DIRECTION. SLOPE MIN. 1/4"/FT. WALK-IN COOLER OR FREEZER RUN TO BACK WALL & ROUTE ALONG WALLS TO RECEPTOR VENT WHEN REQUIRED ESCUTCHEON AIR GAP FLOOR SINK 2X PIPE DIA. NOTE: PIPE MATERIAL TO BE MINIMUM OF TYPE M COPPER PIPE. INDIRECT WASTE SCHEDULE INDIRECT WASTE LINE TO RECEPTOR TYPICAL METHODS FOR RUNNING CONNECTION AT CASE LOCAL AUTHORITY. BELOW RIM IF APPROVED BY NOTE: I.W. LINE MAY TERMINATE ENDS OPEN VERTICAL TEE WITH BOTH DISCHARGE POINT OPEN TEE TO BE BELOW CASE FLOOR SINKDRAIN LINE SUPPORTED AS SHOWN VENT AS REQUIRED 2X PIPE SIZE OUTLET. LGR. THAN PIPE SIZE MIN. ONE 1/2" I.D. LESS THAN BUT NOT OUTLET SAME AS YES NO NO YES YES NO OVER 15' 5'-15' 0-5' SIZE PIPE REQ'D VENT REQ'D TRAP LENGTH PIPE 2X PIPE SIZE FLOOR SINK VENT AS REQUIRED TRAP TRAP CONNECTION AT CASE (MIN) 2X PIPE DIA.THE LOCAL HEALTH DEPT. REQUIREMENTS DIRECTION OF THE BUILDING CODE AND NOTE: INSTALL FLOOR SINK AS PER THE FLOOR SINK OUTLET TO P-TRAP ALUMINUM DOME STRAINER CONCRETEALL FLOOR SINKS SHALL HAVE A TRAP PRIMER OR A TRAP SEAL. FINISHED FLOOR MATERIALSFINISHED FLOOR MATERIALS INSTALL DEEP SEAL P-TRAPS ON ALL FLOOR SINKS. FLOOR CLEANOUT LONG SWEEP FITTINGS 2" PIPE SINK 2" OR 3" PIPE 2" WALL CLEANOUT FOOT VENT 45° FITTING SLOPE SLOPE 2" PIPE 2" PIPE 2" PIPE 2" VENT THRU ROOF WALL NOTE: RAISE RETURN VENT AS HIGH AS POSSIBLE UNDER THE DRAIN BOARD. USE 2(45°) FITTINGS AND ONE LONG RADIUS ELBOW TO MAKE LOOP. INSTALL LONG SWEEP FITTINGS BELOW FLOOR AND RUN HORIZONTALLY TO NEAREST PARTITION. USE 45° FITTINGS FOR EASY STOPPAGE CLEANING. F S 1 1/2"FW1 TOP VIEW KITCHEN SERVICE R E A R V IE WWALL IC E S O D A M A C H IN E O U T L E T DELI PREP DRINK YOGURT SLUSH A S P O S S IB L ECOUNTER. H O L D 1 " H OL E IN C L OS E T O U N IT D R A IN L IN E A S L IN E , M IN IM U M D R A IN3/4 "FLOOR CLEANOUT (FCO) CLEANOUT TO GRADE (COTG) WALL CLEANOUT (WCO) FLOOR LINE WALL WASTE LINE FLOOR LINE BALANCE OF PIPING SAME AS COTG BRASS C.O. PLUG W/ COUNTER-SUNK HEAD FINISHED GRADE 16" SQ. CONCRETE PAD. TROWEL SMOOTH AND BEVEL EDGES. CI WASTE LINE. LENGTH TO SUIT 1/8 CI BEND CLEANOUT AND ACCESS COVER. TOP OF COVER TO BE FLUSH W/ TOP OF FLOOR CHROME WALL COVER AND SCREW MAY EXTEND AS WASTE OR VENT CLEANOUT TEE W/ PLUG BALANCE OF PIPING SAME AS COTG 6" 1/8 CI BEND 1/8 CI BEND INSULATION (TYP.) HOT WATER LINE COLD WATER LINE UNISTRUT-LENGTH VARIES DEPENDING ON LINE SIZES AND NUMBER OF LINES BEING SUPPORTED. (USE P-4000 UNISTRUT) ATTACH 1/2" HANGER RODS TO MEMBER (TYP.) CONDUIT FOR ELECTRICAL WIRING OR OTHER PIPING NOTE: USE SIMILAR HANGERS FOR STEAM, CONDENSATE, AND AIR LINES 1 2 3 4 FEMALE x FEMALE LONG SWEEP BEND (TYP EACH END)COUPLER NOTES: EXTEND MIN. 7" THRU SLAB 100' MAX. SLAB A. B. PULL CORD PULL CORD CHASE SUPPLIED AND INSTALLED BY P.C. USE OF TEES, SHORT SWEEP 45° AND 90° ELLS IS NOT ALLOWED. CHASE SHALL BE LAID IN STRAIGHT RUNS BETWEEN RISER POINTS WITH THE USE OF ONLY TWO LONG SWEEP 90° ELLS (36" MINIMUM RADIUS) INTERIOR OF CHASE SHOULD BE SMOOTH WITH NO SHARP OR ROUGH JOINT EDGES TO RESTRICT OR CATCH BEVERAGE TUBING. 4"⌀MIN. PVC PIPE WITH PULL CORD ENTIRE RUN OF PIPE TO PULL BEVERAGE LINES. 2"⌀MIN. PVC PIPE FOR CO² LINE W/PULL CORD ALONG ENTIRE LENGTH OF PIPE. PROVIDE AND INSTALL TEMPORARY CAP OVER EACH RISER (USE NO CEMENT) 4"⌀X6" THICK FOAM CAP FOR BEVERAGE CHASE PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY: APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.10/9/2020 11:17:52 AMPLUMBING DETAILS 2020020.47 FINAL DRAWINGS 07/10/20 Author Approver TYPE B REMODEL P2.01MAVERIK, INC.3202 W. USTICK RD.MERIDIAN, ID 83646MAVERIK C-STORE #405SCALE:1/4" = 1'-0"1 REFRIGERATION CONDENSATE DRAIN DETAIL SCALE:1/8" = 1'-0"2 TYPICAL INDIRECT WASTE DRAIN DETAIL SCALE:1/4" = 1'-0"3 FLOOR SINK (FS1 & FS2) DETAIL SCALE:1/4" = 1'-0"7 ISLAND SINK INSTALLATION DETAIL SCALE:1/4" = 1'-0"8 ICE BIN DRAIN LINE DETAIL SCALE:1/8" = 1'-0"4 CLEANOUTS DETAIL SCALE:1/8" = 1'-0"5 TYPICAL PIPE HANGER SUPPORT DETAIL SCALE:1/8" = 1'-0"6 BEVERAGE & CO 2 SUPPLY CHASE DETAIL GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 10/09/20 TIE INTO EXISTING VENT MAIN, FIELD VERIFY LOCATION OF MAIN TIE INTO EXISTING VENT MAIN, FIELD VERIFY LOCATION OF MAIN EXISTING CLEANOUT EXISTING GREASE WASTE CAPPED AT FLOOR EXISTING GREASE WASTE CAPPED AT FLOOR EXISTING GREASE WASTE CAPPED AT FLOOR EXISTING GREASE WASTE CAPPED AT FLOOR (E) 3"ø G W (E) 2"ø G W(E ) 4 "ø G W FS-1 FS-1 FS-1 FS-1 (E)FS-1 P5 FS-1 3 "ø G W 3 "ø G W 2"ø V2"ø V2"ø V3"ø GW 3"ø GW (E ) 4 "ø S A N(E ) 2 "ø V (E ) 2 "ø V 4"ø SAN (E)FD-1 (E)FD-1 P5 P3 P2 P2 EXISTING 3" VTR. TIE INTO EXISTING VENT MAIN, FIELD VERIFY LOCATION OF MAIN WCO 1 1/2"ø V 2"ø SAN1/2"ø FW1/2"ø FW1/2"ø FW1/2"ø HW1/2"ø CWP7 P7 P7 P7 1/2"ø FW 1/2"ø HW 1/2"ø CW3/4"ø FW1/2"ø FW3/4"ø FW1/2"ø HW1/2"ø HW1/2"ø HW1/2"ø HW1/2"ø HW1/2"ø HWTIE WATER PIPING INTO EXISTING MAINS, FIELD VERIFY LOCATION OF MAINS TIE WATER PIPING INTO EXISTING MAINS, FIELD VERIFY LOCATION OF MAINS TIE WATER PIPING INTO EXISTING MAINS, FIELD VERIFY LOCATION OF MAINS TIE WATER PIPING INTO EXISTING MAINS, FIELD VERIFY LOCATION OF MAINS TIE WATER PIPING INTO EXISTING MAINS, FIELD VERIFY LOCATION OF MAINS TIE WATER PIPING INTO EXISTING MAINS, FIELD VERIFY LOCATION OF MAINS 72.1 18 21 96 95 11 9C 9C N102 1/2"ø FWTIE WATER PIPING INTO EXISTING MAINS, FIELD VERIFY LOCATION OF MAINS P5 P3 P3 P2 P5 P2 P2 (E) 2"ø CW 3/4"ø CW3/4"ø CW1/2"ø HW1/2"ø CW3/4"ø CW3/4"ø CW 1/2"ø HW1/2"ø CW(E ) 1 1 /2 "ø C W (E) 1"ø C W (E) 1"ø CW(E) 1"ø CWPROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY: APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.10/9/2020 11:17:55 AMPLUMBING ISOMETRICS 2020020.47 FINAL DRAWINGS 07/10/20 Author Approver TYPE B REMODEL P2.02MAVERIK, INC.3202 W. USTICK RD.MERIDIAN, ID 83646MAVERIK C-STORE #405SCALE:1 WASTE RISER SCALE:2 WATER ISOMETRIC GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 10/09/20 GENERAL NOTES 1. THE ARCHITECTURAL, STRUCTURAL, PLUMBING AND ELECTRICAL DRAWINGS AND OTHER RELATED DOCUMENTS SHALL BE CONSIDERED A PART OF THE MECHANICAL CONTRACT, AS FAR AS THEY APPLY TO THE MECHANICAL SYSTEMS, AS IF REFERRED TO IN FULL. 2. ALL FIELD CONDITIONS AND JOB SITE DIMENSIONS ARE TO BE VERIFIED PRIOR TO COMMENCEMENT OF WORK. 3. ALL CONSTRUCTION WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE BUILDING CODES. (IMC, UMC, IBC, UBC, STATE AND LOCAL CODES). 4. THE LOCATION OF ALL PENETRATIONS SHALL BE COORDINATED WITH ARCHITECTURAL AND STRUCTURAL DRAWINGS. 5. MECHANICAL CONTRACTOR SHALL PROVIDE LEVELING PLATFORM AND CURBS FOR ALL NECESSARY ROOF EQUIPMENT. COORDINATE WITH ROOF EQUIPMENT SUPPLIER. 6. ALL FIELD CONDITIONS AND DIMENSIONS SHOWN ON THE DRAWINGS SHALL BE VERIFIED PRIOR TO SUBMITTING BIDS, NO ALLOWANCE WILL BE MADE FOR NOT COMPLYING WITH THIS REQUIREMENT. 7. CONTRACTOR SHALL NEATLY LABEL ROOF MOUNTED EQUIPMENT WITH 4" MINIMUM LETTERING WITH PLAN EQUIPMENT NAME PLATE TAG #. I.E.: CU-18A, CU-21A 8. ALL EQUIPMENT SHALL BE FURNISHED WITH (THREE) MAINTENANCE MANUALS, EQUIPMENT SCHEDULES, TAGS AND LETTER OF GUARANTEE IN A BINDER(THREE) WITH TABS, AS PER PROJECT BOOK SPECIFICATION, SECTION 01700. 9. MAINTAIN 4'-0" SERVICE CLEARANCE BETWEEN PARAPET AND ROOF MOUNTED EQUIPMENT. 10. ALL REFRIGERATION PIPE SIZES SHALL BE PER MANUFACTURER'S RECOMMENDATIONS OR SPECIFICATIONS. USE 404A REFRIGERANT. 11. NO REFRIGERATION PIPE PENETRATIONS PERMITED IN RETAIL AREA. COORDINATE IN FIELD PRIOR TO PERFORMING WORK. 12. ICE MACHINES REQUIRE INSULATION ON BOTH LIQUID AND SUCTION LINES. ALL OTHER REFRIGERATION EQUIPMENT SHALL HAVE ONLY SUCTION LINES INSULATED. 13. ALL SITE ASSEMBLED REFRIGERATION PIPING SHALL BE SUBJECTED TO TESTING PER IMC SECTION 1108.1 PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY:APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.10/9/2020 11:17:39 AMMECHANICAL LEGENDS & NOTES 2020020.47 FINAL DRAWINGS 07/10/20 Author Approver TYPE B REMODEL M0.01MAVERIK, INC.3202 W. USTICK RD.MERIDIAN, ID 83646MAVERIK C-STORE #405WET BULB WB WEIGHT WT WATT W VOLUME VOL VALVE V THERMOSTAT T STAT TEMPERATURE DIFFERENCE TD TEMPERATURE TEMP SUPPLY AIR SA SUCTION SUCT STATIC PRESSURE SP STANDARD STD SQUARE SQ SPECIFICATION SPEC REFRIGERANT (12, 22, ECT.) R12, R22 PRESSURE, STATIC SP PRESSURE DROP PD PRESSURE PRES PSI GAGE PSIG POUNDS PER SQUARE INCH PSI POUNDS PER SQUARE FOOT PSF POUNDS LBS PHASE (ELECTRICAL) PH PERCENT % OUTSIDE AIR OA NUMBER NO. NOT TO SCALE NTS NOT IN CONTRACT NIC NORMALLY CLOSED N.C. NORMALLY OPEN N.O. NOISE CRITERIA NC MINIMUM MIN MILES PER HOUR MPH MAXIMUM MAX LIQUID LIQ LINEAR FEET LF LEAVING WATER TEMPERATURE LWT LEAVING AIR TEMPERATURE LAT LATENT HEAT LH KILOWATT KW FREQUENCY (ELECTRICAL) HZ DIAMETER DIA Ø DEW-POINT TEMPERATURE DPT BRAKE HORSEPOWER BHP AVERAGE AVG APPROXIMATE APPROX APPARATUS DEW POINT ADP AMPERE (AMP, AMPS) AMP AMBIENT AMB ALTERNATING CURRENT AC ABOVE FINISHED FLOOR AFF MECHANICAL ABBREVIATIONS CONNECT TO EXISTING PIPE RISING UP PIPE DROPPING DOWN REFRIGERANT LIQUID REFRIGERANT SUCTION EQUIPMENT DESIGNATION DESIGNATION NUMBER DIA. DIAMETER CD CONDENSATE SYMBOL & ABBREVIATION DESCRIPTION LEGEND MECHANICAL SYMBOLS RS RL CD 18, 18A THIS PROJECT CONSISTS OF AN EXISTING CONVENIENCE STORE REFRESH OF STORE FIXTURES AND STORE EQUIPMENT. THE EXISTING HVAC SYSTEMS, IE: RTUS, DUCTWORK, HOOD OR THERMOSTATS, ARE TO REMAIN WITH THE FOLLOWING MODIFICATIONS. AN EXISTING SALES AREA DIFFUSER MAY REQUIRE A MINOR ADJUSTMENT TO REDIRECT THE AIRFLOW AWAY FROM THE NEW BONFIRE GRILL CANOPY AND NEW HOT DOG GONDOLA TO PREVENT AIR FROM BLOWING DIRECTLY ONTO EITHER OF THEM. THE SUPPLY DIFFUSERS ON THE RTU SERVING THE BOH AND RESTROOM AREA WILL BE RE-BALANCED TO PROVIDE ADDITIONAL AIRFLOW TO THE RESTROOMS. THE EXISTING DRINK STATION AREA IS BEING RECONFIGURED AND THE EXISTING SODA/ICE DISPENSER IS BEING REPLACED WITH (2) TWO NEW SODA/ICE DISPENSERS WITH ROOF MOUNTED REMOTE CONDENSERS. THE INSULATED REFRIGERANT PIPING WILL ROUTE ON THE ROOF AND PENETRATE THE SPACE IN TO THE ADJACENT WALL. NO REFRIGERATE PIPING SHALL BE INSTALLED AND ROUTED THROUGH THE SALES AREA. THE EXISTING RESTROOM EXHAUST FAN IS BEING REPLACED. THE NEW FAN IS TO BE INSTALLED ON THE EXISTING ROOF CURB AND CONNECT TO THE EXISTING DUCTWORK. THE WALK-IN COOLER/FREEZER CONDENSERS ARE BEING REPLACED. THE NEW UNITS ARE TO BE INSTALLED ON THE EXISTING ROOF CURB. MECHANICAL DESIGN INTENT GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 10/09/20 1 1A 2A 5A 3A 4A 1A 2A 5A 3A 4A 2 3 1821 CONDENSING UNIT #18A (CUBE ICE MAKER) 325 LBS 18A CONDENSING UNIT #21A (CUBE ICE MAKER#2) 130 LBS 7A 7A 6A6A 8A 8A REFRIGERATION SCOPE OF WORK REFRIGERATION CONTRACTOR SHALL INSTALL ALL OWNER PROVIDED EQUIPMENT (CONDENSERS, EVAPORATORS, EXPANSION VALVES, SOLENOID VALVES, & CONTROL VALVES). FOLLOW MANUFACTURER'S INSTALLATION MANUALS & THESE REFRIGERATION PLANS & DETAILS. REFRIGERATION CONTRACTOR SHALL PROVIDE ALL PIPING EXCEPT FOR THE ICE MACHINES. PROVIDE 1/2" INSULATION ON ALL PIPING. CONTRACTOR SHALL CHARGE EACH SYSTEM WITH REFRIGERATE TO THE PROPER VOLUMES PER MANUFACTURER'S EQUIPMENT MANUALS. WALL LIQUID LINE UNISTRUT SUCTION LINE 1/2" INSULATION (R-3) BRASS COUPLER PIPE SUPPORT INSTALL GASKET OR TAPE TO ISOLATE PIPE. B-LINE "VIBRACLAMP" BUT SERIES PIPE CLAMP COUPLER ROOF NOTE: PAINT EXPOSED REFRIGERATION PIPE INSULATION WITH TWO COATS OF WHITE FINISH TO PROTECT FROM UV RAYS. SLEEVE PROVIDED & INSTALLED BY REFRIGERATION CONTRACTOR ROOF SEALANT AROUND ENTIRE PIPE OPENING. ALLOW WATER TO DRAIN AWAY FROM OPENING ON TO THE ROOF CONDENSER WEATHER PROOF DISCONNECT LIQUID & SUCTION LINES WITH INSULATION ELECTRICAL CONDUIT CURB (BY ROOFING CONTRACTOR) SEISMIC BRACING #10 SHEET METAL SCREW 12" ON CENTER SEE 7/S5.10 FOR CURB ANCHORING DETAIL CONDENSER MOUNTING ANGLE ROUTE DOWN TO EQUIPMENT REFRIGERATION EQUIPMENT SCHEDULE 18A 18 21A 21 ICE MAKER #1 HOSHIZAKI 60"X17"X30"325 HOSHIZAK KMS-2000MLH 115V/1∅2.5 30x24x33 2063/4"1/2"3/4"1/2" EQUIPMENT CONDENSER MANUFACTURER MODEL #VOLTAGE H.P.FLA MOPD WEIGHT EVAPORATOR MANUFACTURER MODEL #VOLTAGE H.P.MCA MOPD L x W x H DIMENSIONS WEIGHT L S LINE SIZES (LBS) LINE SIZES SRK-20H 15 CUBE ICE MAKER #2 SCOTSMAN ERC311-32 32"X34"X34"130 SCOTSMAN N1322R-32 208V/1∅13.9 23x24x27 2251/2"3/8"1/2"3/8"20 L SL x W x H DIMENSIONS R6 R1 R7 R2 WALK-IN COOLER WALK-IN FREEZER HEAT CRAFT HEAT CRAFT 208V/3∅ 208V/3∅MOHO10X63C MOHO25L63CFT 1/15 1/15 16.0 23.2 20 30 24x28x17 38x28x17 172 259 7/8"3/8" 7/8"3/8" HEAT CRAFT HEAT CRAFT SM090AEEF SME090BEE 208V/1∅ 120V/1∅2.0 1.6 54x29x9 76x27x9 146 190 7/8"3/8" 7/8"3/8"20 20 (DEFROST)208V/1∅13.1 (2400 W) (3) 1/15 POWERED BY #18 POWERED BY #21 PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY: APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.10/9/2020 11:17:41 AMMECHANICAL FLOOR PLAN 2020020.47 FINAL DRAWINGS 07/10/20 Author Approver TYPE B REMODEL M1.01MAVERIK, INC.3202 W. USTICK RD.MERIDIAN, ID 83646MAVERIK C-STORE #405SCALE:1/4" = 1'-0"1 MECHANICAL PLAN KEY NOTES 1 EXISTING TYPE II HOOD TO REMAIN. NO MODIFICATIONS REQUIRED. 2 EXISTING DUCTWORK TO REMAIN. NO MODIFICATIONS REQUIRED. 3 EXISTING DUCTWORK TO REMAIN. CONTRACTOR SHALL ADJUST DIFFUSER DIRECTIONAL THROW IF BLOWING ON NEW BONFIRE GRILL CANOPY. COORDINATE WITH STAFF TO ENSURE NO AIR BLOWS DIRECTLY ONTO PREPARED FOOD OR BEVERAGES. 1A INSTALL REFRIGERATION PIPING FROM ROOF CONDENSER TO EVAPORATOR, PROVIDE SWEEPING ELBOWS IN SUCTION LINES. INSTALL 1/2" THICK INSULATION ON SUCTION LIN. SEE ALL INSULATION JOINTS WITH TAPE. PAINT INSULATION EXPOSED ON THE ROOF WITH (2) TWO COATS WHITE FINISH TO PROTECT INSULATION FROM UV RAYS. SEE REFRIGERATION DETAIL ON THIS SHEET. 2A SEAL ALL ROOF & REFRIGERANT CASE WALL & CEILING WITH EXPANDABLE INSULATION. PROVIDE FLASHING AROUND EXPOSED PIPES. 3A SUPPORT REFRIGERATION PIPES EVERY 6 FEET. ISOLATE PIPING WITH GASKET OR TAPE FROM PIPE COUPLER. 4A CONDENSER & EVAPORATOR, CONDUIT & POWER BY ELECTRICAL CONTRACTOR. CONTROL CONDUIT BY ELECTRICAL CONTRACTOR. INSTRUCT ELECTRICAL CONTRACTOR ON ROUTING OF CONTROL CONDUIT. CONTROL WIRE BY ELECTRICAL CONTRACTOR. ALL FINAL CONDENSER, EVAPORATOR, SOLENOID & STAT. CONTROL WIRING BY ELECTRICAL CONTRACTOR. START UP BY REFRIGERATION CONTRACTOR. REFRIGERATION CONTRACTOR TO SEAL CONDUIT PENETRATIONS WITH EXPANDABLE FOAM INSULATION. 5A INSULATE BOTH REFRIGERATION PIPES. INSTALL 1/2" THICK INSULATION ON BOTH SUCTION AND LIQUID LINES. SEAL ALL INSULATION JOINTS WITH TAPE. PAINT INSULATION EXPOSED ON THE ROOF WITH TWO (2) COATS WIHTE FINISH TO PROTECT INSULATION FROM UV RAYS. SEE REFRIGATION DETAIL ON THIS PAGE 6A ROUTE REFRIGERATION PIPES DOWN WALL BEHIND ICE MAKERS. PENETRATE WALL AND CONNECT TO ICE MAKER. HIDE PIPING FROM VIEW. 7A INSTALL CONDENSER ON ROOF CURB AND ATTACH WITH #10 SHEET METAL SCREWS 12" ON CENTER. 8A CONTRACTOR SHALL RECLAIM REFRIGERANT FROM EXISTING ICE MACHINES PRIOR TO DEMOLITION IN ACCORDANCE WITH LOCAL AND NATIONAL CODE REQUIREMENTS.CONTRACTOR SHALL REMOVE CONDENSING UNITS FROM ROOF. SEE ARCHITECTURAL DEMOLITION SHEET FOR ADDITIONAL INFORMATION AND FOR COORDINATION PRIOR TO PERFORMING WORK. REFRIGERATION NOTES SCALE:1/8" = 1'-0"3 REFRIGERATION PIPING ON ROOF DETAIL SCALE:1/8" = 1'-0"2 REFRIGERANT PIPING DETAIL N GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 10/09/20 ELECTRICAL GENERAL NOTES GENERAL NOTES: 1. APPLICABLE CODES: 2015 IBC, 2017 NEC, 2015 IFC, LOCAL BUILDING CODES. 2. THE ELECTRICAL SYSTEMS DEFINED BY THESE PLANS AND THE SPECIFICATIONS ARE TO BE CONSTRUCTED AS COMPLETE AND OPERABLE SYSTEMS AND SHALL BE BID WITH THIS INTENT. THE CONTRACTOR SHALL VISIT THE SITE, READ ALL THE RELEVANT DOCUMENTS, AND BECOME FAMILIAR WITH THE TYPE OF CONSTRUCTION AND WORK TO BE ACCOMPLISHED. SHOULD ANY ERROR, OMISSION, OR CONFLICT EXIST IN EITHER THE PLANS OR SPECIFICATIONS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER IN WRITING BEFORE SUBMITTING THEIR BID PRICE SO A CHANGE CAN BE ISSUED IN A PRE-BID ADDENDUM. OTHERWISE, THE CONTRACTOR AND/OR EQUIPMENT SUPPLIERS SHALL SUPPLY THE PROPER MATERIALS AND LABOR TO INSTALL COMPLETE AND OPERABLE SYSTEMS INCLUSIVE OF THE ORIGINAL BID. WHEN EACH ELECTRICAL SYSTEM IS COMPLETE, THE CONTRACTOR SHALL TEST AND CONFIRM ITS PROPER OPERATION. ANY INCOMPLETE SYSTEM SHALL BE MADE COMPLETE AND OPERABLE PRIOR TO PROJECT CLOSEOUT. 3. THE ARCHITECTURAL AND MECHANICAL PLANS ARE CONSIDERED A PART OF THE ELECTRICAL DOCUMENTS SO FAR AS ANY ELECTRICAL ITEMS THEY MAY CONTAIN. THE ELECTRICAL CONTRACTOR SHALL REFER TO AND COORDINATE WITH THEM. NO EXTRA COST SHALL BE ALLOWED FOR FAILURE TO COORDINATE THE CONTRACT DOCUMENTS WITH OTHER TRADES AND/OR IF EQUIPMENT DIMENSIONS ARE GREATER THAN SPECIFIED AND/OR DIMENSIONED ON THE PLANS. 4. THE ELECTRICAL CONTRACTOR SHALL PROVIDE EQUIPMENT, MATERIALS, AND LABOR FOR THE CONNECTIONS OF ALL EQUIPMENT SHOWN ON THE PLANS - ARCHITECTURAL, MECHANICAL, ETC. 5. THIS PROJECT IS TO BE INSTALLED IN STRICT ACCORDANCE WITH THE MOST RECENT LOCAL, STATE, AND NATIONAL CODES. IF AT ANY TIME DURING OR AFTER CONSTRUCTION SOMETHING IS FOUND TO BE INSTALLED IN VIOLATION OF THESE CODES LISTED ABOVE, IT SHALL BE CORRECTED BY THE CONTRACTOR. 6. ALL EQUIPMENT PROVIDED BY THE EC SHALL BE LISTED AND LABELED BY A NATIONALLY RECOGNIZED TESTING AGENCY, ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION, AND BE PROPERLY INSTALLED FOR THE CONDITIONS AND SPACE THAT EQUIPMENT IS BEING INSTALLED WITHIN. 7. THE EC SHALL INSTALL A SEPARATE EQUIPMENT GROUNDING CONDUCTOR IN EACH CONDUIT RUN. CONDUIT SHALL NOT BE USED AS AN EQUIPMENT GROUNDING CONDUCTOR. THE EC SHALL GROUND THE ELECTRICAL SYSTEM IN ACCORDANCE WITH LOCAL AND NATIONAL CODES. 8. CONDUIT LAYOUTS SHOWN ON THE PLANS ARE DIAGRAMMATIC, NOT INDICATING THE ROUTING REQUIRED. THE EC SHALL ROUTE THE CONDUITS AS REQUIRED BY THE CONDITIONS OF THE INSTALLATION AND SHALL COORDINATE WITH DUCTWORK, PIPING, EQUIPMENT, BUILDING STRUCTURE, AND OTHER POTENTIAL OBSTRUCTIONS. 9. THE CONTRACTOR SHALL ALLOW THE MOVEMENT, BEFORE ROUGH-IN, OF ANY ELECTRICAL PANEL, DEVICE, LUMINAIRE, ETC. A DISTANCE OF 10 FEET WITHOUT REQUIRING ADDITIONAL COST TO THE PROJECT. 10. THE EC SHALL SECURE ALL CONDUIT TO THE STRUCTURE AS IT IS SET IN PLACE USING INDUSTRY STANDARD METHODS AND PRACTICES. TO ASSURE ALL DEVICES ARE RIGIDLY SET, THE ELECTRICAL CONTRACTOR SHALL SECURE ALL DEVICE BOXES WITH BRACKETS, HANGERS, ETC. DESIGNED FOR THE APPLICATION. 11. MINIMUM SIZE CONDUIT SHALL BE 3/4" UNO. CONDUIT INSTALLED WITHIN THE BUILDING IN DRY LOCATIONS WITHIN WALL, CEILINGS, OR EXPOSED NOT SUBJECT TO PHYSICAL DAMAGE SHALL BE EMT WITH STEEL SET SCREW FITTINGS. IN EXTERIOR LOCATIONS (EXCEPT FOR THE SERVICE ENTRANCE) THE CONDUIT SHALL BE EMT WITH COMPRESSION GLAND TYPE FITTINGS. UNDERGROUND CONDUIT SHALL BE PVC (SCH. 40) WITH GRC ELBOWS AND RISERS WRAPPED IN CORROSION RESISTANT MATERIALS WHERE IN DIRECT CONTACT WITH THE SOIL. 12. FLEXIBLE CONDUIT SHALL BE LIMITED TO CONNECTIONS TO LIGHT FIXTURES AND FINAL CONNECTIONS TO MOTORS OR OTHER EQUIPMENT SUBJECT TO VIBRATION. LENGTHS OF FLEXIBLE OR SEAL-TITE CONDUIT SHALL NOT BE GREATER THAN 72 INCHES. 13. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL EMPTY CONDUITS WITH 200LB RATED NYLON PULL CORD. 14. BEFORE ANY ELECTRICAL CONDUIT, BOXES, ETC. ARE COVERED (FLOOR, CEILINGS, WALLS, ETC.), THEY SHALL BE APPROVED BY THE INSPECTING OFFICER (INSPECTOR). 15. WHERE WIRE SIZE IS NOT SHOWN ON THE DRAWINGS FOR 20A, 120VAC BRANCH CIRCUITS, THE CIRCUIT SHALL CONSIST OF 2#12 (CU,THWN) + 1#12 (CU,THWN) GND IN 3/4" EMT CONDUIT. THIS WIRE SIZE SHALL BE INCREASED TO #10 (CU,THWN) FOR BRANCH CIRCUITS WITH OVERALL LENGTHS EXCEEDING 125' TO ACCOMMODATE FOR VOLTAGE DROP. REFER TO EQUIPMENT SCHEDULES, FEEDER SCHEDULES, AND NOTES ON DRAWINGS FOR ALL OTHER BRANCH CIRCUIT AND FEEDER WIRE/CONDUIT SIZING. 16. CONDUCTORS SHALL BE COPPER, 600VAC RATED, TYPE THHN/THWN-2 UNO. CONDUCTORS UP TO #10AWG SHALL BE SOLID AND CONDUCTORS #8AWG OR LARGER SHALL BE STRANDED. 17. METAL CLAD CABLING MAY BE USED BETWEEN DEVICES SUCH AS LIGHTING, RECEPTACLES, SWITCHES, ETC. UNLESS OTHERWISE REQUIRED BY THE NEC. HOME RUNS SHALL BE INSTALLED IN CONDUIT. MC CABLE SHALL NOT BE INSTALLED EXPOSED. 18. EC SHALL CLEAN THE ENTIRE ELECTRICAL SYSTEM AFTER COMPLETION OF THE INSTALLATION. REMOVE ALL FINGER PRINTS, FOREIGN MATTER, PAINT, DIRT, GREASE, AND UN-NEEDED LABELS OR STICKERS FROM FIXTURES AND EQUIPMENT. REMOVE ALL RUBBISH AND DEBRIS ACCUMULATED DURING INSTALLATION FROM THE PREMISES. 19. IT IS THE INTENT OF THE CONSTRUCTION DOCUMENTS FOR ALL DEVICES TO BE FLUSH MOUNTED AND CONDUIT/CABLING INSTALLED CONCEALED WITHIN WALLS/CEILINGS. IN AREAS WHERE CONDUIT MUST BE INSTALLED EXPOSED IT SHALL BE COORDINATED WITH THE ARCHITECT AND/OR ENGINEER. ALL EFFORTS SHALL BE MADE TO CONCEAL WIRING METHODS. 20. ALL PENETRATIONS THROUGH FIRE RATED ASSEMBLIES SHALL BE SEALED WITH FIRE STOPPING, IE. 3M BRAND CAULK, PUTTY, STRIP AND SHEET FORMS, DOW CORNING 3-6548 SILICONE RTV FOAM. 21. COORDINATE LOCATION OF WALL MOUNTED DEVICES WITH CABINETRY AND OTHER WALL OBSTRUCTIONS. COORDINATE CEILING MOUNTED DEVICES WITH CEILING OBSTRUCTIONS. ANY DEVICES THAT NEED TO BE RELOCATED MUST BE BROUGHT TO THE ATTENTION OF THE ELECTRICAL ENGINEER PRIOR TO ROUGH-IN FOR NEW LOCATION. 22. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO COORDINATE PLACEMENT OF ALL DEVICES INSTALLED WITHIN THE CEILING SUCH AS LIGHTING, SPEAKERS, FIRE SPRINKLERS, SMOKE/HEAT DETECTORS, ETC. 23. PRIOR TO TRENCHING IN ANY AREA, THE CONTRACTOR SHALL COORDINATE WITH COMMUNICATIONS/DATA, CABLE TV, GAS, AND WATER UTILITY PROVIDERS (BLUE STAKES), AND HAVE ALL UTILITIES IN THE AREA IDENTIFIED. IN ADDITION, THE CONTRACTOR SHALL OBTAIN THE SERVICES OF A SUBCONTRACTOR SPECIALIZING IN THE LOCATION OF UNDERGROUND STRUCTURES TO IDENTIFY ANY OBSTACLES IN THE PATH OF TRENCHING PRIOR TO COMMENCING WORK. DAMAGE TO ANY UNDERGROUND STRUCTURES SHALL BE REPAIRED BY THE CONTRACTOR. LIGHTING NOTES: 24. ALL BATTERY POWERED OR CONTINUOUS BURN LUMINAIRES SHOWN ON THE PLANS, SUCH AS EXIT LIGHTS, NIGHT LIGHTS, OR EMERGENCY LIGHTS, SHALL BE CONNECTED TO THE UN-SWITCHED LEG OF THE LIGHTING CIRCUIT FEEDING THAT AREA. 25. ALL LUMINAIRES SHALL BE SUPPORTED FROM THE BUILDING STRUCTURE AND NOT THE CEILING GRID OR OTHER NONSTRUCTURAL MEMBERS. 26. TO MAINTAIN CONSISTENT LIGHT QUALITY, FOR ANY ONE LAMP TYPE SUPPLIED, LAMPS SHALL BE OF THE SAME MANUFACTURER, SURFACE TEMPERATURE, COLOR RENDERING INDEX, LAMP EFFICACY, LUMEN OUTPUT, AND STARTING CHARACTERISTICS FOR ALL INSTALLED. 27. LIGHT FIXTURES INSTALLED IN DAMP OR WET LOCATIONS SHALL BE UL LISTED FOR INSTALLATION IN THE PROPER ENVIRONMENT. CARE SHOULD BE TAKEN TO ENSURE THAT DIFFUSERS AND LENSES ARE APPROPRIATE FOR THEIR INSTALLED USE AND PREMATURE DISCOLORATION WILL NOT RESULT DUE TO EXPOSURE TO UV LIGHT, CHEMICALS, OR OTHER CONDITIONS. POWER NOTES: 28. ELECTRICAL CONTRACTOR SHALL CONFIRM MINIMUM CODE (NEC) WORKING CLEARANCE BEFORE INSTALLING ANY ELECTRICAL PANELS OR CABINETS AND SHALL MOVE THE PANELS IF REJECTED BY AN INSPECTOR. IF CLEARANCE IS NOT POSSIBLE, THE ENGINEER SHALL BE NOTIFIED IMMEDIATELY IN WRITING. 29. WIRING DEVICES SHALL BE WHITE IN COLOR WITH NYLON COVER PLATES. EXTERIOR OUTLETS SHALL HAVE CAST COVERS WITH FLIP TYPE LIDS UNO. 30. THE EC SHALL MAINTAIN ELECTRICAL CONTINUITY TO REMAINING EQUIPMENT WHEN ANY EXISTING ELECTRICAL EQUIPMENT IS REMOVED. 31. EC SHALL COORDINATE WITH EQUIPMENT SUPPLIERS ON THE EXACT LOCATIONS OF ALL EQUIPMENT AND ELECTRICAL CONNECTIONS PRIOR TO ROUGH-IN. THE EC SHALL MAKE THE FINAL CONNECTION TO ALL EQUIPMENT UNLESS OTHERWISE DIRECTED BY THE EQUIPMENT SUPPLIER. OBTAIN FROM SUPPLIERS ALL WIRING DIAGRAMS FOR EQUIPMENT PRIOR TO ANY ROUGH-IN. TO ASSURE THAT PROPER CHARACTERISTICS ARE PROVIDED, ANY INCORRECT WIRING OR DEVICES INSTALLED BY THE EC WITHOUT THE WIRING DIAGRAM SHALL BE CORRECTED AT THE EC'S EXPENSE. PROVIDE COPIES OF WIRING DIAGRAMS WITHIN EACH PIECE OF EQUIPMENT AND ADDITIONAL COPIES WITH THE OPERATION AND MAINTENANCE MANUALS. 32. EC SHALL COORDINATE WITH THE MECHANICAL CONTRACTOR TO PROVIDE CONDUIT AND DEVICE MOUNTING BOXES FOR THERMOSTATS AND OTHER MECHANICAL CONTROLS. REFER TO MECHANICAL DRAWINGS FOR THE LOCATION OF THERMOSTATS. 33. PROVIDE A 20AMP, 120VAC RECEPTACLE INSTALLED AT AN ACCESSIBLE LOCATION FOR THE SERVICING OF HEATING, AIR CONDITIONING, AND REFRIGERATION EQUIPMENT PER NEC 210.63. RECEPTACLE SHALL BE OF THE GROUND FAULT CIRCUIT INTERRUPTING TYPE, INSTALLED WITHIN A CAST METAL BOX, AND WITHIN 25' OF ALL REQUIRED EQUIPMENT. DATA/TELECOM NOTES: 34. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ROUGH-IN ONLY FOR THE TELECOM/CATV SYSTEMS. THIS SHALL CONSIST OF A FOUR SQUARE DEVICE MOUNTING BOX WITH CONDUIT TO ABOVE ACCESSIBLE CEILING SPACE OR TO THE CEILING SPACE ABOVE IF OPEN. CABLING, JACKS, FACEPLATES, TESTING AND TERMINATIONS SHALL BE PROVIDED AND INSTALLED BY OTHERS. ROOF NOTES: 35. ELECTRICAL CONTRACTOR TO INSTALL A ROOF JACK (BOOT) FOR ALL CONDUIT PENETRATIONS THROUGH THE ROOF. ALL ROOF PENETRATION SEALS SHALL BE IN ACCORDANCE WITH THE ROOF WARRANTY AND BE COMPLETELY SEALED WITH ROOF ADHESIVE. UTILIZE PROPER CLAMPING METHODS TO SEAL BOOT AROUND CONDUIT. ELECTRICAL SYMBOL SCHEDULE SYMBOL DESCRIPTION MOUNTING NOTES CO AR MM F FIRE ALARM HORN 7' - 6" FIRE ALARM STROBE 7' - 6" FIRE ALARM HORN STROBE 7' - 6" FIRE ALARM GONG 7' - 6" FIRE ALARM DUAL ACTION MANUAL PULL STATION 4' - 0" FIRE ALARM ADDRESSABLE CONTROL RELAY FIRE ALARM MONITOR MODULE FIRE ALARM CONTROL PANEL 6' - 6" TO TOP FIRE ALARM ANNUNCIATOR PANEL 4' - 0" PHOTOELECTRIC SMOKE DETECTOR RATE OF RISE/HEAT DETECTOR CARBON MONOXIDE DETECTOR DUCT SMOKE DETECTOR 6 FIRE SMOKE DAMPER FIRE RISER TAMPER SWITCH FIRE RISER FLOW SWITCH ELECTROMAGNETIC DOOR HOLDER 2' - 0" F T SURFACE SURFACE SURFACE DUCT S S S S S S S LIGHT FIXTURE - SURFACE OR RECESSED SEE DRAWINGS 1 EMERGENCY LIGHT FIXTURE - SURFACE OR RECESSED SEE DRAWINGS 1, 2 EMERGENCY LIGHT FIXTURE - OPEN STRIP LIGHT FIXTURE - CEILING MOUNTED CEILING 1 LIGHT FIXTURE - PENDANT/CHANDELIER CEILING 1 LIGHT FIXTURE - DOWNLIGHT CEILING 1 LIGHT FIXTURE - WALL WASH DOWNLIGHT CEILING 1 LIGHT FIXTURE - WALL MOUNTED WALL 1 LIGHT FIXTURE - WALL BRACKET WALL 1 LIGHT TRACK WITH FIXTURES SURFACE 1 EXIT FIXTURE - WALL MOUNT WALL EXIT FIXTURE - CEILING MOUNT CEILING EXIT FIXTURE W/ EMERGENCY HEADS - WALL MOUNT WALL EXIT FIXTURE W/ EMERGENCY HEADS - CEILING MOUNT CEILING DUAL HEAD EMERGENCY LIGHT FIXTURE WALL 1, 2 AREA LIGHT FIXTURE - POLE MOUNTED POLE 1 PHOTO-ELECTRIC CELL WITH RELAY SURFACE 1 OCCUPANCY SENSOR - CEILING MOUNT CEILING 1 LIGHTING RELAY/POWER PACK SURFACE 1 TIME CLOCK - 7 DAY 5' - 0" WALL OCCUPANCY SENSOR SWITCH 4' - 0" SINGLE POLE SWITCH 4' - 0" DOUBLE POLE SWITCH 4' - 0" THREE WAY SWITCH 4' - 0" FOUR WAY SWITCH 4' - 0" DIMMER SWITCH 4' - 0" LOW VOLTAGE SWITCH 4' - 0" OS 2 3 4 D LV 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 LIGHT FIXTURE - OPEN STRIP 1 1, 2 SEE DRAWINGS SEE DRAWINGS EMERGENCY LIGHT FIXTURE - WALL MOUNTED WALL 1, 2 EMERGENCY LIGHT FIXTURE - WALL BRACKET WALL 1, 2 EMERGENCY LIGHT FIXTURE - DOWNLIGHT CEILING 1, 2 TC PP PC EM JUNCTION BOX SURFACE WALL JUNCTION BOX 1' - 6" UNO FLOOR JUNCTION BOX FLOOR DISCONNECT SWITCH - NON-FUSED 5' - 0" UNO 4 DISCONNECT SWITCH - FUSED 5' - 0" UNO 4 COMBINATION MAGNETIC STARTER/DISCONNECT 5' - 0" UNO MOTOR STARTER 5' - 0" UNO CONTACTOR 5' - 0" UNO MOTOR SURFACE METER - PLAN VIEW PUSH BUTTON SWITCH 4' - 0" EMERGENCY POWER SHUTOFF SWITCH 4' - 0" PANELBOARD - SURFACE MOUNTED 6' - 6" TO TOP PANELBOARD - RECESSED 6' - 6" TO TOP TRANSFORMER - PLAN VIEW TELEPHONE TERMINAL BOARD WALL WALL PAD/FLOOR DISCONNECT SWITCH - SHUNT TRIP F J J J 5' - 0" UNO 4 LPNR CIRCUIT BREAKER MCB PANEL - ONE-LINE MLO PANEL - ONE-LINE CURRENT TRANSFORMER CT ENCLOSURE - ONE-LINE TRANSFORMER - ONE-LINE PAD MOUNT XFMR - ONE-LINE METER - ONE-LINE FUSED SWITCH GROUND OH RISER CABLE/WIRE SIZE TAGXXX XXXA XXXAXP AUTOMATIC TRANSFER SWITCH GROUND SLEEVE - ONE-LINE FUSED DISCONNECT - ONE-LINE M S S XX X X KEYED NOTE TAG MECHANICAL/ELECTRICAL EQUIPMENT TAG OTHER EQUIPMENT TAG X ABBREVIATIONS NOTES WIRING / CONDUIT UNDERGROUND/FLOOR WIRING CONDUIT TURNED UP CONDUIT TURNED DOWN CIRCUIT HOME RUN TO PANEL: # OF ARROWHEADS INDICATE # OF CIRCUITS (SEPARATE NEUTRAL PER CIRCUIT). BOTH EX. INCLUDE AN EQUIP. GROUND. 1.SEE LIGHTING FIXTURE SCHEDULE FOR TYPE, MOUNTING, AND OTHER SPECIFICS. 2.CONNECT EMERGENCY AND/OR EXIT LIGHTS TO THE UNSWITCHED SIDE OF THE AREA LIGHTING BRANCH CIRCUIT. 3.ARROW DENOTES EXIT DIRECTION. 4.USE HEAVY DUTY FOR 480 VOLT. 5.MOUNT SWITCH AT DOOR JAM PER MANUFACTURER'S INSTRUCTIONS. 6.PROVIDE UL LISTED DEVICE TO BE USED WITH THE FIRE ALARM PANEL/SYSTEM OR PROVIDE A MONITOR MODULE TO CONNECT INTO FIRE ALARM SYSTEM. 7.PROVIDE RACEWAY WITH OUTLETS 12" ON CENTER UNO. MCB - MAIN CIRCUIT BREAKER MCC - MOTOR CONTROL CENTER MDP - MAIN DISTRIBUTION PANEL MLO - MAIN LUGS ONLY (N) - NEW NIC - NOT IN CONTRACT NEC - NATIONAL ELECTRICAL CODE NFPA - NATIONAL FIRE PROT. ASSN. NL - NIGHT LIGHT NR - NOT REQUIRED NTS - NOT TO SCALE PC - PLUMBING CONTRACTOR PNL - PANEL POC - POINT OF CONNECTION POS - POINT OF SALE (R) - RELOCATED REC - RECEPTACLES RMC - RIGID METAL CONDUIT SCA - SHORT CIRCUIT AMPERES SES - SERVICE ENTRANCE SWITCHGEAR SPD - SURGE PROTECTIVE DEVICE TTB - TELEPHONE TERMINAL BOARD TR - TAMPER RESISTANT TYP - TYPICAL UNO - UNLESS NOTED OTHERWISE VA - VOLT/AMPS VIF - VERIFY IN FIELD VR - VANDAL RESISTANT WP - WEATHERPROOF/NEMA 3R WU - WITH UNIT XFMR - TRANSFORMER AFCI - ARC FAULT CKT INTERRUPTER AFF - ABOVE FINISHED FLOOR AFG - ABOVE FINISHED GRADE AIC - AMPS INTERRUPTING CAPACITY AL - ALUMINUM ATS - AUTOMATIC TRANSFER SWITCH BC - BARE COPPER BFC - BELOW FINISHED CEILING BFG - BELOW FINISHED GRADE CKT - CIRCUIT CND. OR C. - CONDUIT CLG - INSTALLED IN CEILING C.R. - CORD REEL CT - CURRENT TRANSDUCER CU - COPPER (E) - EXISTING TO REMAIN EC - ELECTRICAL CONTRACTOR EM - EMERGENCY (F) - FUTURE FACP - FIRE ALARM CONTROL PANEL FLA - FULL LOAD AMPS FVNR - FULL VOLTAGE NON REVERSING GC - GENERAL CONTRACTOR GFCI - GROUND FAULT CKT INTERRUPTER GND - GROUND IG - ISOLATED GROUND LCP - LIGHTING CONTROL PANEL LTG - LIGHTING LV - LOW VOLTAGE MC - MECHANICAL CONTRACTOR MCA - MINIMUM CIRCUIT AMPS THERMAL OVERLOAD SWITCH 4' - 0" UNO PILOT LIGHT SWITCH 4' - 0" DUPLEX OUTLET, 20A, 120VAC 1' - 6" UNO DUPLEX OUTLET, 20A, 120VAC - GFCI DUPLEX OUTLET - SPLIT WIRED DUPLEX OUTLET - ISOLATED GROUND DUPLEX OUTLET WITH USB PORTS DUPLEX OUTLET - OCCUPANCY SENSOR CONTROLLED DUPLEX OUTLET, 20A, 120VAC - CEILING CEILING DUPLEX OUTLET, 20A, 120VAC - FLOOR FLOOR FOURPLEX OUTLET, 20A, 120VAC FOURPLEX OUTLET, 20A, 120VAC - GFCI FOURPLEX OUTLET - ISOLATED GROUND APPLIANCE OUTLET - 208/240V SINGLE PHASE 18" OR 48" APPLIANCE OUTLET - 208/480V 3-PHASE 18" OR 48" TELEPHONE OUTLET DATA OUTLET DUAL TELEPHONE/DATA OUTLET CABLE TELEVISION OUTLET DUAL TELEPHONE/DATA OUTLET - FLOOR FLOOR TH P OS CEILING DATA OUTLET/ WIRELESS ACCESS POINT CEILING DATA OUTLET - FLOOR FLOOR 1' - 6" UNO 1' - 6" UNO 1' - 6" UNO 1' - 6" UNO 1' - 6" UNO 1' - 6" UNO 1' - 6" UNO 1' - 6" UNO 1' - 6" UNO 1' - 6" UNO 1' - 6" UNO 1' - 6" UNO SPEAKER CEILING SECURITY CAMERA CEILING S APPLIANCE OUTLET - 208/240V SINGLE PHASE - GFCI 18" OR 48" APPLIANCE OUTLET - 208/480V 3-PHASE - GFCI 18" OR 48" 8.FOR ALL GFCI RECEPTACLES THAT ARE INACCESSIBLE, CONTRACTOR SHALL USE GFCI BREAKERS. PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY: APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.10/8/2020 4:51:02 PMELECTRICAL NOTES & SCHEDULES 2020020.47 FINAL DRAWINGS 07/10/20 Author Approver TYPE B REMODEL E0.01MAVERIK, INC.3202 W. USTICK RD.MERIDIAN, ID 83646MAVERIK C-STORE #405GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 10/09/20 J J JJJ SS J J J J J 8 8 8 7 7 15 16 13 'A' 42 42 42 42 23 33 72.1 72.1 4 9695 14 20D 110 1 1 1 1 1 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 3 3 3 1 1 1 CLG CLG CLGCLG 7 7 77 21 4 'M1' 112 112 8 8 9 46 1 6 6 22 111 99 99 'B' B-13 B-15 B-2,4 B-31,33 B-26,28 A-61 A-53 48 5 B-22 18 'D' 9C 9C 11 1 (4) 3/4"C. (9) 3/4"C. 11 11 (2) 3/4"C. '8' 97 16 20A 22 5 5 5 48 5 5 9C 9C 11 (2) 3/4"C. 1 A-49,51 A-54,56 11 11 PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY: APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.10/8/2020 4:51:08 PMELECTRICAL POWER PLAN 2020020.47 FINAL DRAWINGS 07/10/20 Author Approver TYPE B REMODEL E3.00MAVERIK, INC.3202 W. USTICK RD.MERIDIAN, ID 83646MAVERIK C-STORE #405SCALE:1/4" = 1'-0"1 ELECTRICAL POWER PLAN KEYED NOTES GENERAL NOTESKEYED NOTES 1. COORDINATE WITH OWNER ALL DATA OUTLET REQUIREMENTS. LOCATE ON PLAN AND PROVIDE NECESSARY. 2. ALL SINGLE PHASE RECEPTACLES 50A AND LESS AND THREE PHASE RECEPTACLES 100A AND LESS THAT ARE 150V TO GROUND OR LESS IN THE KITCHEN, FOOD PREP AREAS, FOOD SERVICE AREAS AND BAR AREAS AND AREAS WHERE RECEPTACLES ARE INACCESSIBLE TO BE GFCI PROTECTED BY GFCI BREAKER. REFER TO EQUIPMENT CONNECTION SCHEDULE NOTES FOR GFCI BREAKER REQUIREMENTS. 3. PROVIDE AND MAINTAIN REQUIRED WORKSPACE, ADEQUATE ILLUMINATION, ACCESS TO WORK SPACE AND HEAD ROOM FOR AND ABOVE ELECTRICAL EQUIPMENT. NO PIPING, DUCTS OR EQUIPPMENT FOREIGN TO ELECTRICAL EQUIPMENT SHALL BE PERMITTED TO BE LOCATED WITHIN A SPACE EXTENDING FROM THE FLOOR TO A HEIGHT OF 6' ABOVE THE EQUIPMENT. PROVIDE PROTECTION FROM PHYSICAL DAMAGE FOR SWITCHBOARDS, PANEL BOARDS, AND OTHER ELECTRICAL EQUIPMENT. NEC 110.27(B). 7 RELOCATE EXISTING DATA, SPEAKERS AND CAMERAS FOR CASHWRAP TO NEW LOCATIONS. COORDINATE EXACT LOCATIONS OF SPEAKERS AND CAMERS WITH OWNER. 8 NEW HAND DRYER. COORDINATE EXACT LOCATION WITH ARCH. 9 EXISTING J-BOX IN WALL.VERIFY AND COORDINATE LOCATION AND TRENCH FROM J-BOX TO NEW POS EQUIPMENT. 11 1 NEW EQUIPMENT TO REPLACE EXISTING EQUIPMENT. E.C. SHALL RUN NEW WIRE AND CONDUIT BACK TO EXISTING CIRCUIT, E.C. SHALL REPLACE BREAKER WITH CORRECT SIZE AS REQUIRED. 2 EXISTING TO REMAIN 3 PROVIDE DATA AND POWER OUTLET IN WALL FOR TV. COORDINATE EXACT LOCATION WITH OWNER. PROVIDE AND INSTALL ONE (1) 1" CONDUIT WITH FOUR (4) CAT-6 CABLES FROM JACK TO NETWORK RACK. LEAVE 18" OF SLACK CABLE AT JACK AND 3 FT OF SLACK CABLE AT RACK. FINAL TERMINATION TO BE COMPLETED BY THE OWNER/SECURITY CONSULTANT. 4 ICE MACHINES(18,20). ROUTE WIRING TO CONDENSER ON ROOF. COORDINATE WITH EQUIPMENT SUPPLIER. 5 VERIFY EXISTING CIRCUIT AND EXTEND TO NEW LOCATION. ENSURE ALL ELECTRICAL REQUIREMENTS MATCH EQUIPMENT SCHEDULE. PROVIDE NEW IF NECESSARY. 6 PROVIDE DATA AND POWER OUTLET FOR FUTURE EQUIPMENT.COORDINATE EXACT LOCATIONS WITH ARCH. AND OWNER. N GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 10/09/20 Sp109 OFFICE 105 DELI PREP 106 KITCHEN SERVICE 101 RETAIL NOT IN SCOPE NOT IN SCOPE T9 T9 T9 2 2 3 3 3 3 3 1 2 1 1 1 1 11 3 PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY: APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.10/8/2020 4:51:10 PMELECTRICAL LIGHTING PLAN 2020020.47 FINAL DRAWINGS 07/10/20 Author Approver TYPE B REMODEL E3.02MAVERIK, INC.3202 W. USTICK RD.MERIDIAN, ID 83646MAVERIK C-STORE #405SCALE:1/4" = 1'-0"1 ELECTRICAL LIGHTING PLAN KEYED NOTES 1 SEE DEMOLITION REFLECTED CEILING PLAN FOR LIGHTS BEING REMOVED IN AREA. 2 NEW LIGHT FIXTURE. SPLICE AND EXTEND EXISTING LIGHT CIRCUIT AND CONTROLS IN AREA TO NEW FIXTURES. 3 EXISTING TO REMAIN UNLESS OTHERWISE NOTED. N GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 10/09/20 CONDENSING UNIT 21A (CUBE ICE MAKER #2) 340 LBS CONDENSING UNIT 18A (ICE MAKER #1) 325 LBS 1 2 3 3 4 PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY: APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.10/8/2020 4:51:10 PMELECTRICAL ROOF PLAN 2020020.47 FINAL DRAWINGS 07/10/20 Author Approver TYPE B REMODEL E3.03MAVERIK, INC.3202 W. USTICK RD.MERIDIAN, ID 83646MAVERIK C-STORE #4051 EXTEND REMOVED CONDENSING UNIT CIRCUIT TO NEW CONDENSER LOCATION. VERIFY EXISTING WIRING AND BREAKER AND REPLACE AS NEEDED TO MATCH EQUIPMENT SCHEDULE. 2 CONDENSER (21A) POWERED VIA ICE MACHINE (21). ROUTE REMOVED ICE MACHINE CIRCUIT TO NEW LOCATION AND REPLACE WIRING, CONDUIT, AND CIRCUIT BREAKER AS NEEDED TO MATCH SCHDULE. 3 EXISTING CONDENSER TO REMAIN 4 NEW GFI RECEPTACLE. SPLICE AND EXTEND EXISTING ROOFTOP RECEPTACLE CIRCUIT TO NEW RECEPTACLE. KEYED NOTES SCALE:1/4" = 1'-0"1 ELECTRICAL ROOF PLAN N GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 10/09/20 PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY: APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.10/8/2020 4:51:11 PMELECTRICAL SCHEDULES 2020020.47 FINAL DRAWINGS 07/10/20 Author Approver TYPE B REMODEL E6.00MAVERIK, INC.3202 W. USTICK RD.MERIDIAN, ID 83646MAVERIK C-STORE #405ELECTRICAL EQUIPMENT CONNECTION SCHEDULE DEVICE NAME Count DESCRIPTION VOLTAGE EQUIPMENT LOAD APPARENT POWER Panel Circuit Number CIRCUIT BREAKE R SIZE WIRE SIZE BASE OFFSET 4 1 ICE/BEVERAGE DISPENSOR 120 V 15.0A 1800 VA 20A/1P #12, #12 GND, IN A 3/4" CONDUIT 4' - 0" 7 2 DISPLAY WARMER 208 V 15A 1400 VA 20A/2P #12, #12 GND, IN A 3/4" CONDUIT 3' - 1" 8 1 DELI CASE 208 V 20.0A 4200 VA 20A/2P #12, #12 GND, IN A 3/4" CONDUIT 3' - 0" 8 1 DELI CASE 208 V 20.0A 4200 VA B 26,28 20A/2P #12, #12 GND, IN A 3/4" CONDUIT 3' - 0" 8 1 DELI CASE 208 V 20.0A 4200 VA B 31,33 20A/2P #12, #12 GND, IN A 3/4" CONDUIT 3' - 0" 9C 2 FOR THERMOFRESH 208 V 27.5A 5720 VA 35A/2P #8, #10 GND, IN A 3/4" CONDUIT 1' - 6" 11 1 CAPPUCCINO MACHINE 120 V 15A 1800 VA 20A/1P #12, #12 GND, IN A 3/4" CONDUIT 3' - 1" 13 1 CONDIMENT DROP IN 120 V 5.0A 600 VA 20A/1P #12, #12 GND, IN A 3/4" CONDUIT 3' - 0" 14 1 FOR MICROWAVE OVEN 120 V 13.4A 1000 VA 20A/1P #12, #12 GND, IN A 3/4" CONDUIT 3' - 0" 15 1 HOT DOG ROLLER GRILL 120 V 15A 1800 VA 20A/1P #12, #12 GND, IN A 3/4" CONDUIT 3' - 0" 16 1 NACHO MACHINE 120 V 2.5A 300 VA 20A/1P #12, #12 GND, IN A 3/4" CONDUIT 3' - 0" 16 1 NACHO MACHINE 120 V 2.5A 300 VA B 13 20A/1P #12, #12 GND, IN A 3/4" CONDUIT 3' - 0" 18 1 ICE MAKER 120 V 2.5A 300 VA 15A/1P #12, #12 GND, IN A 3/4" CONDUIT 1' - 6" 18A 1 ICE MAKER CONDENSING UNIT 208 V 11A 3960 VA 20A/3P #12, #12 GND, IN A 3/4" CONDUIT 1' - 6" 20A 1 OVEN/PROOFER 208 V 29A 10440 VA 40A/3P #8, #10 GND, IN A 1" CONDUIT 1' - 6" 20D 1 EXHAUST HOOD FOR EQUIPMENT 20A 120 V 3.3A 396 VA 20A/1P #12, #12 GND, IN A 3/4" CONDUIT 1' - 6" 21 1 ICE MAKER 208 V 13.9A 2891 VA 20A/2P #12, #12 GND, IN A 3/4" CONDUIT 1' - 6" 21A 1 ICE MAKER CONDENSING UNIT (POWERED FROM 21) 208 V 1.5A 500 VA - #12, #12 GND, IN A 3/4" CONDUIT 1' - 6" 22 1 REFRIGERATED PREP UNIT 120 V 9A 1080 VA 20A/1P #12, #12 GND, IN A 3/4" CONDUIT 1' - 6" 22 1 REFRIGERATED PREP UNIT 120 V 9A 1080 VA B 15 20A/1P #12, #12 GND, IN A 3/4" CONDUIT 1' - 6" 33 1 ICE CREAM MERCHANDISER 120 V 15.6 1872 VA 20A/1P #12, #12 GND, IN A 3/4" CONDUIT 1' - 6" 42 4 POS STATION 120 V 2.5A 360 VA 20A/1P #12, #12 GND, IN A 3/4" CONDUIT 1' - 6" 48 1 CREAMER DISPENSER 120 V 2.5A 360 VA 20A/1P #12, #12 GND, IN A 3/4" CONDUIT 3' - 1" 72.1 2 FROZEN CARBONATED BEV. 208 V 20.5A 4800 VA 30A/2P #8, #10 GND, IN A 3/4" CONDUIT 4' - 0" 78 1 TEA BREWER 120 V 11.7A 1284 VA 20A/1P #12, #12 GND, IN A 3/4" CONDUIT 2' - 4" 95 1 F'REAL 120 V 15.0A 1800 VA 20A/1P #12, #12 GND, IN A 3/4" CONDUIT 4' - 0" 96 1 F'REAL 208 V 6.5A 800 VA 20A/2P #12, #12 GND, IN A 3/4" CONDUIT 4' - 0" 97 2 SPEED OVEN 208 V 40A 8300 VA 50A/2P #6, #10 GND, IN A 1" CONDUIT 1' - 6" 99 1 PIZZA OVEN 208 V 20.5A 4800 VA A 49,51 30A/2P #10, #10 GND, IN A 3/4" CONDUIT 1' - 6" 99 1 PIZZA OVEN 208 V 20.5A 4800 VA A 54,56 30A/2P #10, #10 GND, IN A 3/4" CONDUIT 1' - 6" 111 1 TORTILLA TOASTER 208 V 24.0A 4992 VA B 2,4 30A/2P #10, #10 GND, IN A 3/4" CONDUIT 1' - 6" 112 1 HAND DRYER 120 V 3.3A 1600 VA A 53 20A/1P #12, #12 GND, IN A 3/4" CONDUIT 1' - 6" 112 1 HAND DRYER 120 V 3.3A 1600 VA A 61 20A/1P #12, #12 GND, IN A 3/4" CONDUIT 1' - 6" Lighting Fixture Schedule LIGHT FIXTURE NAME MANUFACTURER CATALOG NUMBER VOLTAGE VA PER FIXTURE MOUNTING FIXTURE DESCRIPTION T9 LSI LAD6 18 40 UE TR6RL 120 V 18 VA RECESSED RECESSED LED DOWNLIGHT 6" APERTURE, 1000 LUMENS, 4K EXISTING POWERED THRU ICE MAKER EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING NOTES: 1. NEW EQUIPMENT WITH PANEL AND CIRCUIT NUMBERS SHOWN AS EXISTING ARE TO REUSE EXISTING CIRCUIT BREAKERS OF EQUIPMENT REMOVED. E.C. SHALL PROVIDE NEW FEEDERS AND CONDUITS BACK TO EXISTING PANELS AND REPLACE ANY BREAKERS REQUIRED. EXISTING GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 EXISTING EXISTING 10/09/20 MPAD MOUNTED XFMR MDP - MAIN DISTRIBUTION CENTER 800A MLO, 120/208V, 3PH, 4W, NEMA 3R, 65KAIC PANEL 'A' 200A 3P PANEL 'B'PANEL 'M1'PANEL 'D' PANEL 'C' 200A 3P 200A 3P 200A 3P PANEL 'L1' 50A PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY: APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.10/8/2020 4:51:12 PMPANEL SCHEDULES 2020020.47 FINAL DRAWINGS 07/10/20 Author Approver TYPE B REMODEL E6.01MAVERIK, INC.3202 W. USTICK RD.MERIDIAN, ID 83646MAVERIK C-STORE #4051. BOLD INDICATES NEW CIRCUIT. PROVIDE NEW CIRCUIT BREAKERS AS NEED. NEW CIRCUIT BREAKERS SHALL MATCH EXISTING TYPE AND AIC. 2. E.C. SHALL REPLACE ANY EXISTING BREAKERS REUSED FOR NEW EQUIPMENT WITH GFCI BREAKERS AS REQUIRED PER CODE. Notes: Additional Est. Demand...26 A Additional Conn. Current:36 A Additional Demand:9440 VA Kitchen Equipment 9600 VA 65.00% 6240 VA Additional Conn. Load:12800 VA Power 3200 VA 100.00% 3200 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Legend: Additional...55 A 20 A 35 A Additional...6400 VA 2400 VA 4000 VA 71 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 72 69 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 70 67 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 68 65 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 66 63 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 64 61 HAND DRYER 20 A 1 1600... 0 VA 1 20 A SPARE 62 59 ---- --0 VA 0 VA -- -- --60 57 ---- -- 0 VA 0 VA 2 25 A EXISTING LOAD 58 55 RTU #3 50 A 3 0 VA 2400...-- -- --56 53 HAND DRYER 20 A 1 1600... 2400...2 30 A PIZZA OVEN (99)54 51 ---- --2400... 0 VA 1 20 A SPARE 52 49 PIZZA OVEN (99) 30 A 2 2400... 0 VA 1 20 A FRONT DOOR 50 47 ---- --0 VA 0 VA 1 20 A SPARE 48 45 ---- -- 0 VA 0 VA 1 20 A SPARE 46 43 OVEN 40 A 3 0 VA 0 VA 1 20 A SPARE 44 41 ---- --0 VA 0 VA 1 20 A WINDOW DISPLAY 42 39 HEAT TRACE 30 A 2 0 VA 0 VA 1 20 A WINDOW DISPLAY 40 37 ---- -- 0 VA 0 VA 1 20 A CIGARETTE DISPLAY 38 35 SPEED OVEN 50 A 2 0 VA 0 VA 1 20 A TOE KICK C.O.36 33 SPARE 30 A 1 0 VA 0 VA 1 20 A CIRGARETTE CASE 34 31 ---- -- 0 VA 0 VA 1 20 A RED BOX 32 29 FROZEN BEVERAGE DISP. 20 A 2 0 VA 0 VA 1 20 A SAFE 30 27 CONDIMENT 20 A 1 0 VA 0 VA 1 20 A SPARE 28 25 CONDIMENT 20 A 1 0 VA 0 VA 1 20 A STORE OUTLETS 26 23 ---- --0 VA 0 VA 1 20 A KITCHEN OUTLET 24 21 FROZEN BEVERAGE DISP. 30 A 2 0 VA 0 VA 1 20 A CASH WRAP 22 19 TREE LIGHTS 20 A 1 0 VA 0 VA 1 20 A ICE MERCH 20 17 WATER HEATER 20 A 1 0 VA 0 VA 1 20 A STORE FRONT 18 15 SPARE 20 A 1 0 VA 0 VA 1 20 A CASH WRAP 16 13 RESTROOM / HALL LIGHTS 20 A 1 0 VA 0 VA 1 20 A SPARE 14 11 BACKROOM/OFFICE LIGHTS 20 A 1 0 VA 0 VA 1 20 A CCTV 12 9 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 10 7 SPARE 20 A 1 0 VA 0 VA 1 20 A RESTROOM OUTLETS 8 5 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 6 3 SPARE 20 A 1 0 VA 0 VA 1 20 A CASH WRAP 4 1 SPARE 20 A 1 0 VA 0 VA 1 20 A ATM 2 CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT Notes: Enclosure:NEMA1 MCB Rating:N/A Mounting:SURFACE Wires:4 Mains Rating:225 A Supply From:Phases:3 Mains Type:MLO Location:ELECTRICAL ROOM 113 Volts:120/208 Wye A.I.C. Rating:22KAIC Existing Panel: A LOAD SUMMARY TOTAL LOAD CHANGE TOTAL LOAD BEING ADDED = 27752 VA ESTIMATED CURRENT ADDED = 77 A EXISTING LOAD (PER EXISTING DRAWINGS) PANEL A = 38 KW, 105 A PANEL B = 35 KW, 99 A EXISTING TOTAL LOAD (PER 12 MONTH PEAK DEMAND) PEAK KW = 64 KW NEW LOAD PER PANEL PANEL A = 52952 VA, 147 A PANEL B = 47800 VA, 133 A NEW TOTAL LOAD (ADDED LOAD + (PEAK*1.25)) NEW TOTAL LOAD = 107752 VA NEW TOTAL CURRENT = 299 A CONTRACTOR IS RESPONSIBLE FOR LOADING ON ALL PANELS PER THE N.E.C CONTRACTORS SHALL KEEP CIRCUIT CONTINUITY TO DEVICES TO REMAIN. E.C. SHALL VERIFY THAT ALL LOADS ON EXISTING PANELS AND FEEDER DO NOT EXCEED THE MAXIMUM LOAD REQUIRED PER THE LATEST EDITION OF THE N.E.C. NOTIFY A/E IF OVERLOAD IS POSSIBLE. ONLY PANELS WITH ADDITION NEW LOADS ARE SHOWN. BESIDES VERIFYING THAT THE NEW LOADS DO NOT OVERLOAD EXISTING PANELS AND FEEDERS. THE CONTRACTOR IS ALSO RESPONSIBLE TO CALCULATE AND VERIFY THAT ALL UPSTREAM PANELS AND FEEDERS ARE NOT OVERLOADED DUE TO THE NEW LOADS. CONTRACTOR SHALL NOTIFY ENGINEER OF LOAD CALCULATIONS PRIORT TO COMMENCING WORK. ALL DEVICES REMOVED DURING DEMOLITION SHALL HAVE ALL ASSOCIATED CONDUIT, WIRING, AND CONTROLS REMOVED BACK TO SOURCE OR NEXT DEVICE THAT REMAINS. SCALE:N.T.S1EXISTING POWER RISER DIAGRAM 1. BOLD INDICATES NEW CIRCUIT. PROVIDE NEW CIRCUIT BREAKERS AS NEED. NEW CIRCUIT BREAKERS SHALL MATCH EXISTING TYPE AND AIC. 2. E.C. SHALL REPLACE ANY EXISTING BREAKERS REUSED FOR NEW EQUIPMENT WITH GFCI BREAKERS AS REQUIRED PER CODE. Notes: Additional Est. Demand...42 A Additional Conn. Current:42 A Additional Est. Demand:14952 VA Additional Conn. Load:14952 VA Power 14952 VA 100.00% 14952 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Legend: Additional...67 A 75 A 0 A Additional...6996 VA 7956 VA 0 VA 71 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 72 69 ---- -- 0 VA 0 VA 1 20 A SPARE 70 67 ---- -- 0 VA 0 VA 1 20 A SPARE 68 65 EXISTING LOAD 30 A 3 0 VA 0 VA 1 20 A SPARE 66 63 SPARE 20 A 1 0 VA 0 VA 1 20 A EXISTING LOAD 64 61 ---- -- 0 VA 0 VA 1 20 A SPARE 62 59 ICE BAGGER 20 A 2 0 VA 0 VA -- -- --60 57 SPARE 20 A 1 0 VA 0 VA -- -- --58 55 SPARE 20 A 1 0 VA 0 VA 3 30 A EXISTING LOAD 56 53 SPARE 20 A 1 0 VA 0 VA -- -- --54 51 SPARE 20 A 1 0 VA 0 VA -- -- --52 49 SPARE 20 A 1 0 VA 0 VA 3 20 A EXISTING LOAD 50 47 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 48 45 CAPPICCINO 20 A 1 0 VA 0 VA 1 20 A SPARE 46 43 FREEZER 20 A 1 0 VA 0 VA 1 20 A SPARE 44 41 BEVERAGE BLENDER 20 A 1 0 VA 0 VA -- -- --42 39 BEVERAGE BLENDER 20 A 1 0 VA 0 VA 2 20 A COUNTER TOP WARMER (7) 40 37 ICE TEA 20 A 1 0 VA 0 VA -- -- --38 35 ICE COFFEE 20 A 1 0 VA 0 VA 2 20 A COUNTER TOP WARMER (7) 36 33 ---- --2100... 0 VA 1 20 A SPARE 34 31 DELI CASE (8)20 A 2 2100... 0 VA 1 20 A ICE MAKER 32 29 ---- --0 VA 0 VA 1 20 A SPARE 30 27 COFFEE BREWER 30 A 2 0 VA 2100...-- -- --28 25 ---- -- 0 VA 2100...2 20 A DELI CASE (8)26 23 COFFEE BREWER 30 A 2 0 VA 0 VA 1 20 A SPARE 24 21 MICROWAVE 20 A 1 0 VA 180 VA 1 20 A GRILL TV/CONV. OUTLETS 22 19 TV MONITORS 20 A 1 0 VA 0 VA 1 20 A HOT DOG 20 17 HOT DOG ROLLER 20 A 1 0 VA 0 VA 1 20 A NACHO 18 15 REFRIGERATED PREP (22) 20 A 1 1080... 0 VA 1 20 A MICROWAVE 16 13 NACHO 20 A 1 300 VA 0 VA 1 20 A FOOD PREP 14 11 ---- --0 VA 0 VA 1 20 A ICE BEVERAGE DISPENSER 12 9 ---- -- 0 VA 0 VA 1 20 A ICE MACHINE 10 7 EXISTING LOAD 30 A 3 0 VA 0 VA 1 20 A BAG-N-BOX 8 5 SPARE 20 A 1 0 VA 0 VA 1 20 A EXHAUST FAN 6 3 CREAM DISPENSER 20 A 1 0 VA 2496...-- -- --4 1 RED BOX SOUTH 30 A 1 0 VA 2496...2 30 A TORTILLA TOASTER 2 CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT Notes: Enclosure:NEMA 1 MCB Rating:N/A Mounting:SURFACE Wires:4 Mains Rating:225 A Supply From:Phases:3 Mains Type:MLO Location:ELECTRICAL ROOM 113 Volts:120/208 Wye A.I.C. Rating:EXISTING Existing Panel: B ALL ELECTRICAL EQUIPMENT AND FEEDERS IN THE MAIN DISTRIBUTION SYSTEM ARE EXISTING TO REMAIN UNLESS OTHERWISE NOTED. GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 10/09/20