Loading...
Site Plan - CivilBREAK ROOM 120 ATM/ELEC 118 STORAGE 114 HALL 113 VAULT 110 BRANCH MANAGER 109 TELLER 112 OFFICE 103 OPEN OFFICE 102 OFFICE 104 OFFICE 105 VESTIBULE 100 COIN 107 LOBBY 101 KIOSK 106 WOMEN 116 MEN 117 HALL 111 MOTHERS ROOM 115 LADDER 119 COIN STORAGE 108 M N89°22'04"W 225.00'S64°4 6' 3 2 " W 1 3 9. 8 6'S0°37'56"W 188.15'C1S89°22'30"E 255.27'N45°46'23"E 40.77'N0°55'10"E 69.27'N6°37'48"E 120.60'N0°55'10"E 16.05'PROFESSIO N AL E OHADIFOETA T S E R IC K SONKSSO R 1 0 8 1 3 NGIN E E RRE G I STERE D 65123 B C 4 A D 651234 JOB N0.: CHECKED BY: SHEET NO. DRAWN BY: DATE: PHASE: CONSULTANT: RKE RKE 06/11/21 CZCMRKDATEDESCRIPTION20225.01 erickson civil 6213 N. CLOVERDALE RD. SUITE 125 - BOISE, ID 83713 T.208.846.8955PRELIMINARYNOT FOR CONSTRUCTION65123 B C 4 A D 651234 JOB N0.: CHECKED BY: SHEET NO. DRAWN BY: DATE: PHASE: CONSULTANT: COPYRIGHT All rights reserved. Reproduction or use in any form or by any means -- graphic, electronic, mechanical, etc. -- without written permission of LOMBARD - CONRAD ARCHITECTS, P.C. is unlawful and subject to criminal prosecution. STAMP: ORCHARD PARK BRANCH IDAHO CENTRAL CREDIT UNION PROJECT SITE W. CHINDEN BLVD.S. LINDER RD.FEET 0 10 20 IDAHO CENTRAL CREDIT UNION 6,190 S.F. 1 1.EXISTING UNDERGROUND POWER. 2.EXISTING OVERHEAD POWER. 3.EXISTING TELEPHONE/FIBER OPTICS. 4.EXISTING GAS LINE. 5.EXISTING POWER. 6.EXISTING PRESSURE IRRIGATION. 7.EXISTING SIDEWALK - RETAIN & PROTECT. 8.EXISTING ASPHALT PAVEMENT. 9.BICYCLE PARKING - 2 LOOP. 10.CONCRETE CURB. 11.CONCRETE SIDEWALK. 12.ASPHALT PAVEMENT. 13.CONCRETE CROSSWALK. 14.PRESSURE IRRIGATION SYSTEM POINT OF CONNECTION. 15.CONCRETE PEDESTRIAN CONNECTION TO PUBLIC ROW. 16.FIRE LANE ACCESS - 20' WIDE; 28' INSIDE RAD.; 48' OUTSIDE RAD. 17.18' x 50' CLEAR TRASH ENCLOSURE ACCESS. 18.SCREENED TRASH ENCLOSURE WITH CANE BOLTS FOR GATES - SEE ARCHITECTURAL FOR DETAIL. 19.SITE LIGHTING. CZC SITE PLAN C1.0 UTILITY & DRAINAGE EASEMENT SUBDIVISION BOUNDARY PROPOSED EDGE OF PAVEMENT PROPOSED GRAVITY IRRIGATION EXITING POWER EXISTING TELEPHONE EXISTING SEWER MANHOLE EXISTING FENCE EXISTING EDGE OF PAVEMENT EXISTING STORM DRAIN EXISTING GAS EXISTING PRESSURE IRRIGATION EXISTING GRAVITY IRRIGATION EXISTING WATER EXISTING SANITARY SEWER PROPOSED PRESSURE IRRIGATION PROPOSED EDGE OF GRAVEL PROPOSED WATER PROPOSED STORM DRAIN PROPOSED FIRE HYDRANT 3 CONTIGUOUS PARKING STALL COUNT GEOTECHNICAL BORE LOCATION FACILITY PROPOSED STANDARD STALLS PROPOSED ACCESSIBLE STALLS PROPOSED BICYCLE PARKING FINANCIAL INSTITUTION 47 2 2 TOTAL PARKING PROPOSED 49 STALLS 2 STALLS TOTAL VEHICULAR PARKING REQ. = 6190 S.F. / 500 = 13 STALLS TOTAL BICYCLE PARKING REQ. = 1 25 VEHICULAR STALLS = 2 OWNER IDAHO CENTRAL CREDIT UNION ARCHITECT LOMBARD CONRAD ARCHITECTS PROJECT MANAGER - ELLIE THOMAS 472 W. WASHINGTON ST. BOISE, ID 83702 T.208.345.6677 ELLIET@LCARCH.COM CIVIL ENGINEER ERICKSON CIVIL, INC. PROJECT MANAGER - ROSS ERICKSON P.E. 6213 N. CLOVERDALE ROAD SUITE 125 BOISE, IDAHO 83712 T.208.846.8955 C.208.867.3954 ROSS@ERICKSONCIVIL.COM LAND USE: FINANCIAL INSTITUTION BUILDING SIZE:6,190 SF GROSS TOTAL SITE AREA:1.83 AC +/- MIN. BUILDING SETBACKS:FRONT=0'; REAR=0'; INTERIOR SIDE=0' LANDSCAPE BUFFERS: S. LINDER RD. = 35' FROM BACK OF CURB W. CHINDEN BLVD. = 35' FROM RIGHT-OF-WAY ZONING: TBD MERIDIAN, ID (C-C) PARCEL NO.:R5262500400 (SEC 25 T.4N R.1W) SITE ADDRESS: PARCEL AREA:1.83 AC +/- LOT & BLOCK:LOT 4 BLK 1 LINDER VILLAGE SUBDIVISION W. CHINDEN BLVD. (HWY 20/26)N. LINDER RD.12 9 8 3 9 9 1 1 2 2 1 2 3 44 4 4 4 5 6 6 6 77 7 7 7 7 8 8 8 9 10 10 10 10 10 1010 10 10 11 11 11 11 11 11 13 15 12 12 12 1212 12 18 DRIVE-THRU LANES 16 16 16 16 17 191919 19 19 19 19 19 19 19