Loading...
DR-4 - 01 FIRST FLOOR PLAN1. DIMENSIONS ARE FROM FACE OF STUD TO FACE OF STUD OR C.L. OF STUD UNLESS OTHERWISE NOTED.2. ACTUAL DIMENSION WITHIN THE GUESTROOM UNITS WILL VARY TO ALIGN WITH BUMP OUTS IN THE EXTERIOR WALL, SHEAR WALLS, EXPANSION JOINTS, AND ADDITIONAL STRUCTURAL REQUIRMENTS, ECT WHERE THEY OCCUR. 3.REFERENCE OVERALL FLOOR PLANS AND BUILDING ELEVATIONS FOR EXTERIOR WINDOW AND DOOR TYPES WITHIN THE APARTMENT FOR LOCATION FIXED PANEL LOCATION.4. G.C. TO VERIFY ALL DIMENSIONS W/MANUFACTURER ON FIXTURES & EQUIPMENT SUPPLIED PRIOR TO CONSTRUCTION.5.REF STRUCTURAL FOR SIZE AND SPACING OF WOOD STUDS, SHEAR WALL LOCATIONS AND CONSTRUCTION, TIE DOWN LOCATIONS AND CONSTRUCTION,6.FRAMER IS RESPONSIBLE FOR PROVIDING ALL BLOCKING REQUIRED FOR ANY WALL HUNG EQUIPMENT, TOILET ACCESSORIES, SHELVING, SHOWER SEAT, EXTERIOR LIGHT FIXTURES, WINDOW TREATIMENTS, HARDWARE, ETC. G.C. RESPONSIBLE FOR COORDINATION WITH OWNER, FF&E VENDOR AND OTHER VENDORS FOR BLOCKING AND ROUGH IN REQUIRMENTS.7. PAINTER SHALL PROVIDE SEALANT AT THE FOLLOWING AREAS: -CABINET ENDS WHERE THEY MEET GYP @ WALLS-AT THE PERIMETER (BOTH SIDES) OF ALL DOORS FRAMES, WINDOW FRAMES, GYP BOARD RETURNS AT OPENINGS.-CONTRACTORS PENETRATING AT RATED WALLS, SHAFTS, FLOOR/CEILING ASSEMBLIES, ROOF/CEILING ASSEMBLIES ARE RESPONSIBLE FOR SEALING.-PLUMBING CONTRACTOR RESPONSIBLE FOR SEALING AT ALL PLUMBING FIXTURES-REF SPECS FOR MORE INFORMATION8.OWNER HAS REQUESTED THAT THE SOUND MAT NOT TO BE RAN THROUGH OUT THE CORRIDORS AS IT WILL RECEIVE CARPET AND PAD WHICH WILL ACT AS THE SOUND TRANSMISSION BARRIER.GENERAL NOTES:INDICATES SOUND BATT LOCATIONSINDICATES 1 HR RATED STRUCTURAL WALL PER IBC 2018 TABLE 601 -REF STRUCTRUAL FOR MORE INFORMATION-NOTE WINDOW AND DOOR OPENINGS IN SOME OF THESE WALLS MAY NOT BE REQUIRED TO BE RATED (MAINLY AT 1ST FLOOR LOBBY AREA)INDICATES CORNER GUARD LOCATIONCG9. GYPSUM BOARD BEHIND BATHTUBS, SHOWERS, & PUBLIC RESTROOM LAVATORY WALLS & URINALS: CEMENT, FIBER-CEMENT, OR GLASS MAT GYPSUM BACKERS IN COMPLIANCE WITH ASTM C 1178, C 1288 OR C 1325 IS REQUIRED BEHIND TILE OR SURROUNDS. WALLS OUTSIDE THE TILED AREA OR TUB/SHOWER SURROUNDS ARE TO BE MOLD RESISTANT GYPSUM BOARD.10. MOLD RESISTANT GYP BD. TO BE USED IN ALL WET AREAS; INCLUDING, BUT NOT LIMITED TO WALLS IN: PRIVATE BATHROOM; PUBLIC RR. ALSO TO BE USED AT: PLUMBING FIXTURE WALLS AND MOP SINKS. FIBER CEMENT BOARD TO BE USED IN LIUE OF MOLD RESISTANT GYP. BD. AS DIRECTED ELSEWHERE.11. REFER TO INTERIOR, ENLARGED PLANS, & EQUIPMENT SHEETS SHEETS FOR FINISH, FURNITURE, EQUIPMENT AND ACCESSORY INFORMATION.12.ALL REQUIRED INTERIOR SIGNAGE TO BE SUBMITTED BY SIGNAGE SUPPLIER SHALL BE PROVIDED IN ACCORDANCE WITH PFC 403.10.1(BY OTHERS)STAIRS2STUDIOA1 UNITB106STUDIOA1 UNITB102STUDIOA1 UNITB104STUDIOA1 UNITB108STUDIOA1 UNITB105STUDIOA1 UNITB101STUDIOA1 UNITB103STUDIOA1 UNITB107STUDIOA1 UNITB109CORRIDORB150LOBBYC102GMOFFICEC104BREAKROOMC110BFITNESSC112MECHC116STUDIOADASHOWER& COMMA4 UNITA1141 BD RMB1 UNITA1121 BD RMB1 COMMUNITA1081 BD RMB1 UNITA1101 BD RMB1 UNITA1041 BD RMB1 UNITA1061 BD RMADA TUBB5 UNITA1171 BD RMB1 UNITA1151 BD RMB1 UNITA1132 BD RMC3 ADASHOWERUNITA1031 BD RMB1 UNITA1111 BD RMB1 UNITA1091 BD RMB1 UNITA107UNISEXC105ELEVE2CORRIDORC150VESTC101DOSOFFICEC106AUNISEXC108LAUNDRYC110ADRYERC110CMECHC110DCORRIDORC150ELECC114MAINTENANCEC118PASSAGEC151MECH106B/A1 A421/B5 A427113344556677889910.41112.812.812.212.213131010.2SSRR.4KKJJHHPPOOGGFFEEDDCCB.2A.4BA.2A.2AA1212MLN13.213.21.211.82210.610.6LOUNGEC103STUDIOA1 UNITB111STUDIOA1 UNITB1102 BD RMC1 UNITA1012 BD RMC1 UNITA1021 BD RMB1 COMMUNITA105CORRIDORA1508.8/B1 A422/B1 A422/B1 A422/B1 A422/B1 A422/B1 A422/C3A429/C1A424/C1A424/A1 A421/A1 A421/A1 A421/A1 A421/A1 A421/A1 A421/A1 A421/A1 A421/A1 A421/A1 A421/A4 A425/B1 A422/B1 A422/B1 A422/B1 A422/B1 A422ALCOVEA151ELEVE1STAIR S1E3CORRIDORA150N.9P.2P.6R.2K.98.2182'-7 3/4"4'-9 1/4"5'-0"4'-4 1/2"1'-7"1'-7"2'-11 1/2"5'-0"5'-11 1/2"6'-0 1/2"5'-0"2'-10 1/2"1'-7"1'-7"2'-11 1/2"5'-0"5'-11 1/2"6'-0 1/2"5'-0"2'-10 1/2"1'-7"1'-7"2'-11 1/2"5'-0"6'-2 1/4"1" E.J.2'-0"2'-3 3/4"12'-0 1/2"2'-5 1/2"3'-11 3/4"3'-9 3/4"5'-0"3'-4"5'-0"7'-6"12'-0"2'-8"8'-8"3'-8"8'-0"8"3'-0"3'-0"15'-8 3/4"15'-6"15'-6"15'-6"15'-6"15'-8 3/4"1" E.J.2'-0"16'-9 3/4"3'-11 3/4"24'-7 3/4"12'-0"2'-8"8'-8"12'-4"3'-0"3'-0"51'-3 3/4"23'-0" 5'-4" 22'-0" 1'-0"8" 4'-0" 8" 3'-4" 3'-4" 15'-4"126'-3 3/4"4'-7"11'-1 3/4"15'-6"15'-6"15'-6"15'-6"15'-8 3/4"1" E.J.22'-9 1/2"4'-6"5'-0"6'-0"6'-0"5'-0"2'-11"1'-7"1'-7"2'-11"5'-0"6'-0"6'-0"5'-0"2'-11"1'-7"1'-7"2'-11"5'-0"6'-2 3/4"1" E.J.2'-9 1/2"5'-0"1'-2"5'-0"1'-2"5'-0"2'-8"9'-11 3/4"223'-11 1/2"12'-4"1'-0"21'-5 1/2" 9'-8" 9'-8" 12'-8" 12'-8" 9'-8" 9'-8" 12'-8" 12'-8" 9'-8" 9'-8" 12'-8"31'-5 3/4"33'-3 3/4" 3'-0 1/2"1'-6 3/4" 5'-0" 1'-7" 5'-1 1/2" 5'-0" 3'-10"2'-6 1/4" 5'-0" 5'-2" 2'-2" 5'-0" 2'-6" 2'-6" 5'-0" 2'-2" 5'-2" 5'-0" 2'-6" 2'-6" 5'-0" 5'-2" 2'-2" 5'-0" 2'-6" 2'-6" 5'-0" 2'-2" 5'-2"5'-0" 2'-6" 2'-6" 5'-0" 5'-2" 2'-2" 5'-0" 2'-6" 2'-6" 5'-0" 2'-2" 5'-2" 5'-0" 2'-6" 3'-10" 5'-0" 4'-7" 2'-5" 5'-0" 3'-0" 5'-0" 2'-7 3/4"2'-3 3/4"4'-0" 27'-0"266'-11 1/2"2'-0" 8'-0" 1'-4"1'-8" 8'-0"1'-3 1/4" 1'-0 3/4"3'-2 1/2" 4'-4" 1'-10"2'-10" 4'-4" 5'-6" 2'-6" 4'-4" 2'-10" 22'-4 1/4" 2'-6" 5'-0" 2'-2" 5'-2" 5'-0" 2'-6" 2'-6" 5'-0"5'-2" 2'-2" 5'-0" 2'-6" 2'-6" 5'-0" 2'-2" 5'-2" 5'-0" 2'-6" 2'-6" 5'-0" 5'-2" 2'-2" 5'-0" 2'-6" 2'-6" 5'-0" 2'-2" 5'-2" 5'-0" 3'-6" 4'-0" 2'-0" 3'-4" 14'-8 1/4" 1'-10 1/2"5'-0" 2'-6" 3'-10" 5'-0" 3'-2" 2'-10" 5'-0" 3'-6"3'-0" 7'-0 3/4" 11'-4" 5'-7 1/4" 5'-4" 1'-0 3/4" 9'-4 1/2" 12'-8" 9'-8" 22'-4 1/4" 9'-8" 12'-8" 12'-8" 9'-8" 9'-8" 12'-8" 12'-8" 9'-8" 9'-8" 12'-8" 25'-0 1/4"21'-4 1/2" 11'-4" 7'-0 3/4" 3'-0 1/2"56'-4"5'-0 3/4"9'-7 1/4"9'-4"2'-8"2'-8"8'-8"12'-4"3'-0"3'-0"2'-1 1/4"5'-0"2'-6"3'-10"5'-0"3'-2"2'-8"2"8'-6"1" E.J.DEMISING WALL15'-8 3/4" C.L. OFDEMISING WALL15'-6" C.L. OFDEMISING WALL15'-6" C.L. OFDEMISING WALL15'-6" C.L. OFDEMISING WALL15'-6" C.L. OF15'-8 3/4" F.O. STUDDEMISING WALL22'-4 1/4" C.L. OF 22'-4" C.L. OF DEMISING WALL 22'-4" C.L. OF DEMISING WALL 22'-4" C.L. OF DEMISING WALL22'-4" C.L. OF DEMISING WALL 22'-4" C.L. OF DEMISING WALL 22'-4" C.L. OF DEMISING WALL 31'-5 3/4" F.O. STUD 9'-6 1/2" 23'-9 1/4" F.O. STUDBUILDING INFORMATION - ROOM DISTRIBUTION MATRIXGUESTROOM TYPEA1STUDIO UNITFIRST FLOORSECOND FLOORTHIRD FLOORFOURTH FLOORPROJECT TOTALGRAND TOTALTOTALGROSS AREA27 19,770 SQ. FT.33 19,605 SQ. FT.33 19,605 SQ. FT.33 19,605 SQ. FT.126 78,585 SQ. FT.SEVEN MOBILITY ACCESSIBLE ROOMS REQUIRED:TWO ROLL-IN SHOWERS REQUIRED. TWO PROVIDEDADA TUB ROOMS: A117, A203, A214, A217, A317ADA ROLL IN SHOWER ROOMS: A103, A114 (DENOTED BY UNIVERSAL ACCESSIBLE SYMBOL)TWELVE HEARING IMPAIRED ROOMS REQUIRED:ROOMS: A105, A108, A114, A201, A208, B211, A313, B306, A404, A413, B406, B412(DENOTED BY UNIVERSAL HEARING IMPAIRED SYMBOL)ONE HEARING IMPAIRED + MOBILITY ACCESSIBLE REQUIRED:ROOM: A114 (DENOTED BY UNIVERSAL SYMBOLS)UNIVERSAL SYMBOLS:MOBILITY ACCESSIBLE:HEARING IMPAIRED ACCESSIBLE:50 STUDIO UNITSUNIT TYPE11116836A1bSTUDIO BALCONY00538A2bSTUDIO BALCONY00112A3STUDIO UNIT00101STUDIO ADA TUBA501001A4STUDIO ADA SHOWER10001B11 BD RM11126635B1b1 BD RM BALCONY006612B21 BD RM02226B31 BD RM00011B51 BD RM ADA TUB1110358 (1) BED ROOM UNITSC12 BD RM24006C1b2 BD RM BALCONY00448C22 BD RM 00112C32 BD RM ADA SHOWER1000118 (2) BEDROOM UNITSC42 BD RM ADA TUB01001A2STUDIO UNIT01001144 TOTAL BEDSB41 BD RM00011DRAWN BY: CHECKED BY:ORIGINAL CONTRACT DOCUMENTSProject No:© All work herein is the exclusive property of GLMV Architecture, Inc. and is not to be copied or used in any way without the expresswritten consent of GLMV Architecture, Inc. All drawings,specification, ideas, designs and arrangements appearingherein constitute the original and unpublished Work of:2020 GLMV Architecture , Inc.ISSUE DATE:PROGRESSPRIN T S N O T FORCONSTRUCTIONBIM 360://20005.20001_WaterwalkHotel_MeridianID_Boise-Revised/WATERWALK_MERIDIAN_PCD_V19_ARCH_REV.rvt5/11/2021 9:39:17 PM05-11-2021SCSLJBNORTH EAGLE ROAD & EAST FRANKLIN DRIVEMERIDIAN, ID 83642WATERWALK CORPORATE LODGINGFIRST FLOOR PLANA10120005.2000105-11-202130%PROGRESSPRINT0'8'12'4'1/8" = 1'-0"FIRST FLOOR PLANAMARKDATEDESCRIPTION