Loading...
DWG_L1-00 OVERALL LANDSCAPE PLAN© 2021 Microsoft Corporation © 2021 Maxar ©CNES (2021) Distribution Airbus DS GVPINDIVIVTIVIVIVIVIVIVGVIVIVIVIVIVIVIVIVIVIVGVXXXXXXXXXX XXXXXXXXXEPEPR/W R/W R/W R/W R/W NORTHQUARTERCORNERSECTION 12CP&F#2015-011237WVWVADWVCODSSSSGVW E L K E R S U B D I V I S I O N NORTH SIXTEENTH WESTSECTION 12NW 1/4. NW 1/430' 40'N O R T H G A T E N O . 3S U B D I V I S I O N G R E G O R Y S U B D I V I S I O N U N I T N O . 3UNPLATTED 1507 NW 8TH STWEST ADA SCHOOL DISTRICTAPN: S1212212415RDRDRDRDRDRDRDRDRDRDRDRDRDRDRDRDRDRDRDRDRDRDADRDRDRDRDRDRDRDRDRDRDRDRDRDRDRDRDRDMWRDRDRDRDRDRDDDMWDMWRDBOLBOLBOLBOLBOLBOLBOLBOLBOLBOLBOLBOLBOLBOLBOLBOLBOL(BASIS OF BEARING)IVIVIVCOCOSRDDWVWVIVDRD10' QWESTEASEMENT (R3)40'64'XX X X EEACEEEEACEVLTVLTVLTVLTVLTVLTVLTVLTEES44.5"W BY 14.125"DON RIGHT ORSPECIFY DRAINLEFT CUTOUTD44.5"W BY 14.125"DON RIGHT ORSPECIFY DRAINLEFTCUTOUTD44.5"W BY 14.125"DON RIGHT ORSPECIFY DRAINLEFTCUTOUTDE1DDDCRR RR RR CRDSRRRR DDDSANSANSANMTRSANSDSD123456789101114151316181712Existing AuditoriumExisting Student Services WingExisting ClassroomsExisting ClassroomsExisting ClassroomsExisting ShopExisting GymnasiumExistingMusicBuildingExisting GymnasiumExistingCafeteriaExistingClassroomsExistingClassroomsProposed additionTOTAL TREES REMOVED:2 TREESTOTAL TREES PROPOSED:7 TREESTOTAL CALIPER REQUIRED FOR MITIGATION: 18"TOTAL CALIPERS PROPOSED:19"TREE TYPESIZE (CAL."CONDITIONSTATUSCAL." TO MITIGATE1.ACER10"GOODREMOVE10"2.ACER8"GOODREMOVE8"3.QUERCUS12"GOODPRESERVEN/A4.PRUNUS10"GOODPRESERVEN/A5.PYRUS4"GOODPRESERVEN/A6.PRUNUS12"GOODPRESERVEN/A7.ACER8"GOODPRESERVEN/A8.MALUS24"GOODPRESERVEN/A9.QUERCUS10"GOODPRESERVEN/A10.GLEDITSIA16"GOODPRESERVEN/A11.GLEDITSIA16"GOODPRESERVEN/A12.GLEDITSIA18"GOODPRESERVEN/A13.GLEDITSIA16"GOODPRESERVEN/A14.ACER16"GOODPRESERVEN/A15.ACER16"GOODPRESERVEN/A16.FRAXINUS10"GOODPRESERVEN/A17.FRAXINUS10"GOODPRESERVEN/A18.FRAXINUS10"GOODPRESERVEN/ATOTAL= 18"CALL OUT NUMBERS COORDINATEWITH NUMBERED TREES BELOW.ALL LANDSCAPED AREAS SHALL HAVE AN AUTOMATIC UNDERGROUND SPRINKLERSYSTEM WHICH ENSURES COMPLETE COVERAGE AND PROPERLY ZONED FORREQUIRED WATER USES.A.PROTECT THE CRITICAL ROOT ZONE OF THE TREES TO BE RETAINED ON SITE:(NOTE: CRITICAL ROOT ZONE IS THE AREA DIRECTLY BELOW THE DRIP LINE OFTHE TREE.)A.1.CONSTRUCT PROTECTIVE FENCING OF CHAIN-LINK AROUND THE CRITICALROOT ZONE PRIOR TO DEMOLITION OR CONSTRUCTION.A.2.DO NOT ALLOW COMPACTION BY EQUIPMENT TRAFFIC DURINGCONSTRUCTION OR DURING DEMOLITION.A.3.DO NOT ALLOW CEMENT TRUCKS TO RINSE WITHIN THE PROTECTIONAREA, ANYWHERE THAT TREE ROOTS EXIST OR IN PLANNED PLANTINGBEDS.A.4.DO NOT STOCKPILE MATERIALS, DEBRIS OR DIRT WITHIN THE TREEPROTECTION AREA.A.5.MAINTAIN WATERING WITHIN THE CRITICAL ROOT ZONE FROM MID-APRILTO MID-OCTOBER AT THE RATE OF NOT LESS THAN THE EQUIVALENT OF 1-1/2" OF WATER OVER THE ENTIRE AREA PER WEEK.A.6.DO NOT TRENCH, EXCAVATE, FILL OR OTHERWISE DISTURB THE SOILWITHIN THE CRITICAL ROOT ZONE.A.7.ADJUST PROPOSED IMPROVEMENT LOCATIONS AS REQUIRED TO AVOIDDAMAGING TREE ROOTS.B.PROTECT THE CROWN AND TRUNK OF TREES TO BE RETAINED ON SITE:B.1.OPERATE EQUIPMENT IN SUCH A WAY AS TO AVOID CONTACT WITH TREETRUNKS OR BRANCHES.B.2.PRUNING OF PUBLIC PROPERTY TREES SHALL BE PERFORMED BY ALICENSED ARBORIST.C.ALL TREES DAMAGED OR DESTROYED DURING CONSTRUCTION SHALL BEREPLACED WITH A 4" CALIPER TREE- SPECIES TO MATCH THE EXISTING.Existing Tree ScheduleMitigation CalculationsTree Protection NotesIrrigation NoteLandscape CalculationsNUMBER OF STREET TREES / LINEAL STREET FRONTAGEEXISTING- NO SITE MODIFICATIONS AT THIS LOCATION PROPOSEDWIDTH OF STREET BUFFERSEXISTING- NO SITE MODIFICATIONS AT THIS LOCATION PROPOSEDBUFFER WIDTH BETWEEN DIFFERENT LAND USESEXISTING- NO SITE MODIFICATIONS AT THIS LOCATION PROPOSED% OF PARKING AREA WITHIN INTERNAL LANDSCAPEEXISTING- NO SITE MODIFICATIONS AT THIS LOCATION PROPOSEDTOTAL NUMBER OF TREES AND SPECIES MIXFULL SITE: EXISTINGIN PROJECT AREA: 7 TREES PROPOSED, 3 SPECIESNO EXISTING OPEN CANALS, CREEKS, DRAINS, PONDS, WETLANDS, FLOODPLAINS, HIGHGROUNDWATER AREAS, OR ROCK OUTCROPPINGS EXIST WITHIN THE PROJECT AREA.Landscape Note*SOME TREE SPECIES MUST BE VERIFIED AT A LATER DATE WHEN LEAVES BUD.#Horizontal Scale: 060'120'1" = 60'Overall Landscape Plan6512365123BCJOB N0.:7CHECKED BY:SHEET NO.7DRAWN BY:DATE:4A4DE462 E. SHORE DR. SUITE 100EAGLE, IDAHO 83616(208) 939-4041THE LAND GROUPCIVIL ENGINEERCONSULTANTS:462 E. SHORE DR. SUITE 100EAGLE, IDAHO 83616(208) 939-4041THE LAND GROUPLANDSCAPE ARCHITECTPHASE:COPYRIGHT All rights reserved. Reproduction or use in any formor by any means -- graphic, electronic, mechanical, etc. -- withoutwritten permission ofLOMBARD - CONRAD ARCHITECTS, P.C.is unlawful and subject to criminal prosecution.STAMP:4/14/2021 3:45:06 PM BIM 360://20024 WASD MMS Cafeteria Remodel/20024-01_Meridian Mid School Cafeteria_ARCH_CENTRAL_2021.rvt 20024.01MD/GWMA/GWWEST ADASCHOOLDISTRICT4-22-21MERIDIAN MIDDLESCHOOLCAFETERIAADDITIONCONDITIONAL USEPERMITMRK DATE DESCRIPTIONTLG PN: 121036File Location:g:\2021\121036\cad\_cup\121036 cup landscape plan.dwgLast Plotted By:melissa drewDate Plotted:Thursday, April 22 2021 at 11:14 AM L1.00OverallLandscape Plan04/22/2021CERTIFICATE OF ZONINGCOMPLIANCE