Loading...
PZ - Pre-app Notes ETT Planning Division IDIA `� �'' PREAPPLICATION APPLICATION DAHO Type of Review Requested Pre-Application Request File number: PREAPP-2021-0068 Assigned Planner: Sonya Allen Related Files: Applicant Information Applicant name: Phone: Applicant address: Email: Owner name: Phone: Fax: Owner address: Email: Agent name(e.g.architect,engineer,developer,representative): Firm name: Phone: Fax: Address: Email: Contact name: Phone: Fax: Contact address: Email: Subject Property Information Location/street address: 1108 NE 2 1/2 ST Assessor's parcel number(s): S 1107244450 Township,range,section: 3N 1 E7 Project Description 33 E Broadway Avenue,Suite 102 • Meridian,Idaho 83642 Phone:(208)884-5533 • Facsimile:(208)888-6854 • Website:www.meridaincity.org 1 Project/Application Name: Cole Valley Christian School Temporary Portables Cole Valley Christian School Temporary Portables The total project consists of installing 4 temporary portables classrooms for the temporary period of 4 years per UDC 11-4-3-14-F1. The portables will require water, sewer, and electrical utilities. 1 ADA stall will also be included to provide an accessible parking stall for the portables. All other parking will be provided by the existing Cole Valley parking lot. There will not be Description of work: an additional trash enclosure as part of this temporary installment. All trash will be carried to existing Cole Valley receptacles. No additional lighting is being proposed with this project. There is existing street lighting at Washington and 2 '/2 street. Cole Valley Christian School needs temporary classroom space while they pursue and construct their new campus. These portables will be removed upon its completion and relocation of the school to its new campus. 33 E Broadway Avenue,Suite 102 * Meridian,Idaho 83642 Phone:(208)884-5533 • Facsimile:(208)888-6854 • Website:www.meridaincity.org 2 Application Information OTHER STAFF COMMENTS Planning Review Notes: " CUP & Design Review is required for temporary portable classrooms (4) if they don't comply with the standards listed in UDC 11-4-3-14F.4. *The existing CUP for the auxiliary field (CUP-13- 013) needs to be modified to allow the proposed structures to be erected on the site (condition #1.3 states, "No structure shall be erected on the site without modification to the subject CUP." * Comply with the specific use standards listed in UDC 11-4-3-14F for portable education institutions. *The proposed use shall be tied to the specific user(i.e. CVCS)- if the user vacates the site earlier than 4 years, the portables shall be removed at that time. *A lesser time period than 4 years may be approved for the portable structures. *A landscaped street buffer may be required. see comments Addressing Plan Review Notes: The portables will be assigned their own unique 2 1/2 street address at the time of address verification request MFD Plan Review Notes: Plans will need to be approved by the building department and fire plan reviewer. A fire hydrant may need to be installed on the corner of 2 1/2 and E Washington. Wastewater Plan Review Notes: • Flow is committed • Plumbing Code issue but verify that services are allowed under the building. Water Plan Review Notes: NO comments. TYPE OF USE PROPOSED Other Type of Use Proposed: Shcool APPLICATION TYPES Conditional Use Modification-MCU: CHECKED PROPERTY INFORMATION Current Land Use: R-15 Total Acreage: 4.5 Acres Prior Approvals(File Numbers): CUP-13-013 ZONING DISTRICT(S) R-15: CHECKED PROJECT INFORMATION Site Plan Date(MM/DD/YYYY): 5.1 1.2021 Landscape Plan Date(MM/DD/YYYY): 5.1 1.2021 Elevations Date(MM/DD/YYYY): 3.16.2007 33 E Broadway Avenue,Suite 102 Meridian,Idaho 83642 Phone:(208)884-5533 • Facsimile:(208)888-6854 • Website:www.meridaincity.org 3 Percentage of Site Devoted to Building: 4.6% Percentage of Site Devoted to Landscaping: 42% Percentage of Site Devoted to Paving: 1% Who will own and Maintain the Pressurized Irrigation System in this Development: Owner of Property, Already exists on site Irrigation District: NA Primary Irrigation Source: NA Secondary Irrigation Source: NA Square Footage of Landscaped Areas to he Irrigated by City Water Connection: NA Minimum Square Footage of Ground Floor Area for Multi-Story Units: NA Proposed Building Height: 11'-10.25" Existing Floor Area(If Applicable): NA Gross Floor Area Proposed: 7,083 SQFT Hours of Operation(Days and Hours): 5 Days 10 hours/Day Number of Standard Parking Spaces Provided: NA Number of Compact Parking Spaces Provided: NA Number of Residential Units: NA Minimum Square Footage of Living Area(Excluding Garage): NA Gross Density: NA I acknowledge that a Site Plan will be uploaded in the attachment section: CHECKED I acknowledge a neighborhood meeting is required prior to application submittal: CHECKED I acknowledge pre-app notes are good for 4 months: CHECKED In Reclaimed Water Buffer: No 33 E Broadway Avenue,Suite 102 • Meridian,Idaho 83642 Phone:(208)884-5533 • Facsimile:(208)888-6854 • Website:www.meridaincity.org 4