Application MaterialsApplicant name:GLENN WALKER, ADP ARCHITECTS Phone: Applicant address:1891 N. WILDWOOD ST., BOISE, ID 83713 Email:gwalker@adpboise.com Owner name:TERRY WHITE, GOLDEN OGDEN PROPERTIES, LLC Phone:Fax: Owner address:2640 INDUSTRIAL DR., OGDEN, UT 84401 Email:tmwhitecpa@earthlink.net Administrative Applicant Information Type of Review Requested File number:A-2021-0083 Assigned Planner:Joseph Dodson Related Files: Subject Property Information Location/street address:3410 W NELIS DR Assessor's parcel number(s):R5629430160 Township, range, section:4N1W34 Agent name (e.g. architect, engineer, developer, representative):GLENN WALKER Firm name:ADP ARCHITECTS Phone:Fax:208-377-3268 Address:1891 N. WILDWOOD ST.Email:gwalker@adpboise.com Contact name:Phone:Fax: Contact address:Email: Project/Application Name:Northwest Specialty Beverage Co. - DES, CZC Description of Work:New 37,020 sq. ft., 32 feet tall, beverage distribution facility on 2.49 acres of land in the I-L zoning district. Project Description Planning Division ADMINISTRATIVE APPLICATION 33 E Broadway Avenue, Suite 102ƔMeridian, Idaho 83642 Phone: (208)884-5533ƔFacsimile: (208) 888-6854ƔWebsite: www.meridaincity.org 1 APPLICATION TYPES Is this application exempt from fees?:No Certificate of Zoning Compliance - CZC:CHECKED Does project have prior approval?:No Does your project contain new construction and/or modifications to an existing building or the site?: No Design Review - DES:CHECKED ADDRESS VERIFICATION Address Verification Permit Number:LDAV-2021-0283 TYPE OF USE PROPOSED Industrial:CHECKED PUBLIC WORKS INFRASTRUCTURE Does this project require the extension of public infrastructure?:No PROPERTY INFORMATION General Location:3410 W Nelis Dr. Current Land Use:I-L Total Acreage:2.485 Prior Approvals (File Numbers):AZ-04-004 ZONING DISTRICT(S) I-L:CHECKED PROJECT INFORMATION Site Plan Date (MM/DD/YYYY):04/19/2021 Landscape Plan Date (MM/DD/YYYY):04/19/2021 Elevations Date (MM/DD/YYYY):05/17/21 Percentage of Site Devoted to Building:34 Percentage of Site Devoted to Landscaping:21 Percentage of Site Devoted to Paving:40 Who will own and Maintain the Pressurized Irrigation System in this Development:Owner Irrigation District:Nampa Meridian Irrigation Primary Irrigation Source:City Water Secondary Irrigation Source:City Water Square Footage of Landscaped Areas to be Irrigated by City Water Connection:22627 Proposed Building Height:33'-11" Gross Floor Area Proposed:37057 Number of Standard Parking Spaces Provided:21 Number of Employees:15 Number of Residential Units:0 Minimum Square Footage of Living Area (Excluding Garage):0 In Reclaimed Water Buffer:Yes Application Information 33 E Broadway Avenue, Suite 102ƔMeridian, Idaho 83642 Phone: (208)884-5533ƔFacsimile: (208) 888-6854ƔWebsite: www.meridaincity.org 3 TIME EXTENSION INFORMATION Number of months extension:24 APPLICATION DISCLAIMER I have read and accept the above terms:CHECKED Your signature:Glenn Walker 33 E Broadway Avenue, Suite 102ƔMeridian, Idaho 83642 Phone: (208)884-5533ƔFacsimile: (208) 888-6854ƔWebsite: www.meridaincity.org 5 ADP Architects – 1891 N. Wildwood St. Boise ID. 83713 – 208-353-0734 GLENN WALKER, AIA ARCHITECT & PLANNER 1891 N. Wildwood St. Boise, Idaho 83713 Ph (208) 353-0734 Date: April 15, 2021 Re: Northwest Specialty Beverage Co. The owners, Northwest Specialty Beverage Co is looking at constructing a new 37,020 sq. ft. beverage distribution facility. The buildings will consist of a Pre-Engineered metal building that will have Architectural Metal Siding. The main body of the building will be a high-grade metal siding called Reversed Box Rib as per picture attached. The main body color will be Sierra Tan. The accent color will be the same a high-grade metal siding Reversed Box Rib, however the color will be Old Town Gray. The pop-outs around the offices and also on the sides of the building will have a stucco textured wall panel as per picture attached. The color of the textured wall panel will be Gray color. We have incorporated variations in height and variation in the wall plane to provide aesthetic interest in the elevations. The building will have parapets on all sides of the building. The roof will be hidden behind the parapet but will be a metal roof. On the South side of the building is the loading dock, due to the nature of the site, this was the best location of the loading dock. The site plan, will have a good mixture of landscaping, paving and building for the overall coverage of the site. This site will have the required parking out front, along with three accessible parking stalls. The proposed 36’-0” high facility is well under the allowed maximum height and the facility is situated such that it complies with the setback requirements for the I-L Zone. We have shown landscaping to enhance the building design which will be consistent with good practices and will have a variety of plant materials. The landscape plan will have similar soft and hard surfaces as the existing surrounding buildings. The site lighting will be done with lights from the building. All wall mounted exterior light fixtures which will transmit the light downward towards the parking only. We hope this project will be acceptable to the planning department. We feel that this project will add to the quality of architecture and distinctiveness of the area, also fit the needs of the owners. Please call if you have any questions or comments, Sincerely, Glenn Walker, AIA, ADP Architects, PA Address verification is complete for record LDAV-2021-0283 Project: Northwest Specialty Beverage Co. Address: 3410 W NELIS DR MERIDIAN, ID 83646 Parcel(s): R5629430160 Lot: 5 Block: 2 Subdivision: MCNELIS SUB All e-mail messages sent to or received by City of Meridian e-mail accounts are subject to the Idaho law, in regards to both release and retention, and may be released upon request, unless exempt from disclosure by law. PROJECT RECAPADDRESS129'-0" WIDE HANDICAP ACCESS AISLE PAINTED w/ TRIPS.345NEW 7'-0" WIDE x 4" THICK CONCRETE SIDEWALK FLUSH W/ASPHALT REFER TO DETAIL 2/A-1.14" WIDE PAINTED PARKING STALL DIVIDER STRIPS, TYP.KEY NOTESSITE DATA6721 STALLS TOTAL (3) H.C. PARKING STALLPARKING STALLSPROVIDEDTOTAL SITE AREA108,226.76 SF OR 3.93 ACRESTOTAL BUILDING AREA:37,057 SF.34 OR 34%BUILDING COVERAGE:PAVED AREA:43,187 SF OR 40%LANDSCAPE AREA:22,627 SF OR 21%8LANDSCAPE ISLAND/AREA, REFER TO LANDSCAPE PLAN, TYP.AS SHOWN9PAINTED HANDICAP SYMBOL, REFER TO DETAIL 3/A-1.1TYP., AT EACH ACCESSIBLE STALL.HANDICAP SIGN MOUNTED TO POST. REFER TO DETAIL 8/A-1.1TYP., AT EACH ACCESSIBLE STALL.3410 W NELIS DRMERIDIAN , ID 83646OTHER AREA:-INCLUDING BUT NOTLIMITED TO: CONCRETE,CURBING, AND SIDEWALKS5%10NEW FACILITY REFER TO FLOOR PLAN SHEETS11OWNER DATAPROPERTY DESCRIPTION: OWNER:GOLDEN OGDEN PROPERTIES, LLC2640 INDUSTRIAL DR., OGDEN, UT. 84401-03206ARCHITECT:Parcel: R5629430160Address: 3410 W NELIS DR MERIDIAN ,ID 83646Subdivision: MCNELIS SUBYear: 2020Land Group Type: SUBParcel Status: Active in 2020Township/Range/Section: 4N1W34Primary Owner:GOLDEN OGDEN PROPERTIES, LLCZone Code: I-LTotal Acres: 2.485Tax Code Area: 03Instrument Number:9999012787Property Description:LOT 05 BLK 02MCNELIS SUBADP ARCHITECTS, PA1891 N. WILDWOOD ST.BOISE, IDAHO 837131212'-0"W x 12'-0" CHAIN LINK FENCE W/ VINYL SLATS TRASHENCLOSURE, REFER TO DETAIL 6/A-1.113BICYCLE RACK PARKING ON CONCRETE PAD,REFER TO DETAIL 7/A-1.15'-0" WIDE SIDEWALK FOR CONNECTION TOSTREETEXTRUDED CURB TYP. AS SHOWN REFER TO DETAIL4/A-1.1STRIPE AREA FOR ACCESSIBLE ROUTE FROM BUILDING ENTRYTO PUBLIC RIGHT-OF-WAY, WIDTH = 5'-0"NEW FIRE HYDRANT LOCATIONSYMBOL LEGENDX= AMOUNT OF PARKING STALLS12,968 sq. ft24,052 sq. ft88'-0"8'-0"8'-0"13'-0"16'-0"81'-0"8'-0"8'-0"9'-0"8'-11"9'-0"8'-0"8'-0"8'-0"9 ' - 0 " 5 4 ' - 0 " 9 ' - 0 " 2 9 ' - 2 " 2 0 ' - 1 0 " 2 5 ' - 1 " 17'-0"9'-0"7'-0" 7 ' - 0 " 9 ' - 0 "17'-0"7'-0"9 ' - 0 "9'-0"833'-6"50'-11"4 5 ' - 0 " 1 6 ' - 7 "92 4 ' - 0 "6666666666222333647'-0"4477710111213651 HC101 HC1 HC1OVERALL SITE PLANSCALE: 1" = 30'-0"NORTHA-1.1OVERALL SITE PLAN 1 ISSUE FOR DR & CofZ COMPLIANCE 04/19/21SHEET NUMBERJOB NO:DATE:DRAWN BY:211092-10-2021G.W.NORTHWEST SPECIALTY BEVERAGE CO. 3410 W NELIS DR MERIDIAN , IDAHO 83646COPYRIGHT ALL RIGHTS RESERVED. THIS DRAWING AND ALL INFO. CONTAINED HEREIN, IS THE PROPERTY OF ARCHITECTURE DESIGNS PLUS P.A., AND MAY NOT BE REUSED WITHOUT THE WRITTEN PERMISSION OF THE ARCHITECT Apr 20, 2021 - 2:50 pmNEW FACILITY FOR:ADP ARCHITECTS 1234567891011121314151691011121314152341DCBAEFGH150'-0"30'-0"30'-0"30'-0"30'-0"30'-0"87'-0"222'-0"120' -0 "24'-0"24'-0"24'-0"30'-0"30'-0"30'-0"30'-0"30'-0"104TCW103WINE COOLER100OFFICE102WOMEN101MEN106WAREHOUSE108WOMEN107MEN114WOMEN113MEN111WAREHOUSE109OFFICE112OFFICE105RECEIVING110WAREHOUSEA-2.0FLOOR PLANSHEET NUMBERJOB NO:DATE:DRAWN BY:211092-10-2021G.W.NORTHWEST SPECIALTY BEVERAGE CO. 3410 W NELIS DR MERIDIAN , IDAHO 83646COPYRIGHT ALL RIGHTS RESERVED. THIS DRAWING AND ALL INFO. CONTAINED HEREIN, IS THE PROPERTY OF ARCHITECTURE DESIGNS PLUS P.A., AND MAY NOT BE REUSED WITHOUT THE WRITTEN PERMISSION OF THE ARCHITECT Apr 15, 2021 - 8:48 pmNEW FACILITY FOR:ADP ARCHITECTS 1 ISSUE FOR DR & CofZ COMPLIANCE 04/19/21 12,968 sq. ft0.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.10.10.10.10.10.00.00.00.10.10.10.10.10.10.10.10.10.10.10.10.10.10.10.10.10.10.20.20.20.20.20.20.30.30.20.10.10.10.20.00.00.10.10.30.40.50.50.40.30.30.40.50.50.30.20.20.30.30.00.00.10.10.20.40.81.11.31.20.70.60.60.70.80.90.60.50.40.30.10.00.10.10.10.10.20.51.22.02.62.82.01.31.01.01.11.21.31.20.70.20.40.30.00.10.10.10.10.10.20.41.22.73.94.53.93.02.21.71.61.61.92.31.50.80.40.20.20.00.10.10.10.10.10.10.10.20.30.51.84.16.05.64.73.82.62.02.02.22.52.41.40.60.20.10.10.10.10.10.10.10.20.20.20.20.20.30.50.71.95.76.45.54.13.12.32.02.12.21.91.40.90.40.10.10.10.10.10.10.20.20.30.30.30.20.20.40.71.01.52.73.43.62.92.21.81.71.81.61.31.00.70.30.20.20.20.10.10.10.20.30.40.40.50.40.20.10.20.50.51.11.31.41.92.21.81.51.31.31.31.10.90.70.40.40.30.20.20.20.20.30.40.60.70.70.60.20.10.20.20.40.81.21.51.61.71.61.10.91.00.90.90.70.60.70.60.50.30.30.20.20.30.40.60.91.01.00.80.20.40.71.01.72.12.01.60.60.70.70.70.60.61.11.00.90.70.60.40.30.30.30.40.60.81.31.61.50.80.30.81.32.12.62.81.10.50.50.50.50.50.41.71.51.41.10.80.60.50.40.40.40.60.81.21.82.12.21.32.63.33.20.40.40.40.31.72.42.01.61.30.90.70.50.50.50.60.81.11.72.22.92.82.80.30.31.12.32.42.11.61.20.90.70.50.50.60.81.01.41.92.22.90.10.20.21.21.82.01.81.41.10.80.60.50.50.60.91.21.51.92.01.70.20.20.21.11.41.61.51.20.90.60.50.40.50.71.11.51.82.01.60.30.30.21.01.21.21.21.00.70.50.40.40.50.71.21.92.22.10.50.50.40.80.90.90.90.80.60.50.40.50.60.91.52.22.82.40.90.60.60.70.70.70.70.60.50.50.60.81.21.82.43.51.30.90.60.50.60.70.70.70.60.60.60.70.91.21.40.91.41.81.20.40.50.70.70.80.70.70.80.90.80.50.30.22.01.91.30.40.50.70.81.01.01.01.00.80.60.50.31.21.61.40.30.50.81.01.41.61.61.61.20.80.60.81.61.31.10.30.50.81.21.72.12.32.01.51.00.71.41.51.00.20.30.61.11.82.83.52.41.61.11.01.81.30.02.12.01.30.00.91.71.60.01.11.01.00.00.40.80.60.00.40.50.01.60.10.30.30.01.82.21.50.50.20.01.41.30.90.40.20.10.90.90.80.50.20.81.11.62.01.71.20.90.70.50.60.71.01.31.92.11.51.31.31.10.70.30.20.60.81.21.61.40.90.70.60.60.60.60.71.01.51.71.21.01.00.80.50.2WL2WL2WL2WL2WL2WL1WL1WL1WL1WL1WL1WL1WL1AL1AL1AL1SHEET NUMBERJOB NO:DATE:DRAWN BY:211092-10-2021J.W.S.NORTHWEST SPECIALTY BEVERAGE CO. 3410 W NELIS DR MERIDIAN , IDAHO 83646COPYRIGHT ALL RIGHTS RESERVED. THIS DRAWING AND ALL INFO. CONTAINED HEREIN, IS THE PROPERTY OF ARCHITECTURE DESIGNS PLUS P.A., AND MAY NOT BE REUSED WITHOUT THE WRITTEN PERMISSION OF THE ARCHITECT Apr 19, 2021 - 11:23 amNEW FACILITY FOR:ADP ARCHITECTSelectricalenJineerinJcompanyenJineerinJ 4 tomorrow800 s. industry way, suite 350meridian, idaho 83642phone: 208.378.4450fax: 208.378.4451e2co project #:world wide web: e2co.com21046NOT FOR CONSTRUCTIONPHOTOMETRIC SITE PLANE1.1SCALE: 1" = 20'-0"PHOTOMETRIC SITE PLANN 12,968 sq. ft 24,052 sq. ft251 LINEAL FEET7 TREES REQUIRED (1 PER 35')7 TREES PROPOSED200 LINEAL FEET 6 TREES REQUIRED (1 PER 35') 1 TREES PROPOSED, 5 EXISTING 372 L INEAL FEET11 TREES REQU IRED (1 PER 35 ' )11 TREES PROPOSED 180' LINEAL FEET 5 TREES REQUIRED (1 PER 35') 3 TREES PROPOSED, 2 EXISTING 347' LINEAL FEET - 0 LOT LINE 0 TREES REQUIRED (1 PER 35') 0 TREES PROPOSED0 AP1AC7 RR2 BM2 GS6 LL7 PS2 CA3 BT4 PS1 MJ6 GT1 CO3 RR1 BT4 PS1 CA6 BT2 FA1 CA2 JH2 CA3 BT2 CV4 PA7 GT4 RR16 CA3 SJ4 PK4 CA3 SJ8 CV8 AP1 EXISTING NATIVE GRASSES TO REMAIN EXISTING PATHWAY TO REMAIN EXISTING NATIVE GRASSES TO REMAIN 2" CAL. CHERRY TREE TO REMAIN 4" CAL. PEAR TREE TO REMAIN 3" CAL. HONEYLOCUST TREES TO BE REMOVED AF9 FIRE PLUG BIKE RACK 3"-4" CAL. HONEY LOCUST TREES TO BE RETAINED (TYP.) 3 0 ' - 9 " W. NELIS D RIVE QUANTITY PLANT IDENTIFICATION KEY EXISTING TREES TO REMAIN PLANTS TO BE INSTALLED PROVIDE SHOVEL EDGING BETWEEN ALL PLANTER BEDS TYPES, SEE PLAN FOR LOCATIONS. PROPERTY LINE (VERIFY) BIKE RACK AS SPECIFIED LAWN AREA - SODDED DWARF TURF TYPE TALL FESCUE OVER APPROVED TOPSOIL, SEE NOTES. 3" DEPTH OF WASHED RIVER ROCK (OR EQUAL) PLACED OVER WEED BARRIER FABRIC NATIVE BASALT BOULDERS (CLEAN FROM CALICHE) 2FT. DIA. IN ALL DRIECTIONS PROPOSED BUILDING JB10 TREES BOTANICAL NAMEKEY COMMON NAME (*NOTE: ALL TREES TO BE GRADE #1) PLANTING SIZE GRASSES/PERRENIALS 2 Gal.SJ Cornus alba 'Bailhalo' Ivory Halo Dogwood CO 5 Gal. SHRUBS Berberis thunbergii 'Crimson Pygmy' Crimson Pygmy Japanese Barberry BT 2 Gal. LL Dilly Dilly English Lavender Lavandula angustifolia 'Dilly Dilly' GT 2" B&B Class II Physocarpus opulus 'Summer Wine' Summer Wine Ninebark 5 Gal.PO CLASS 4' hgt. x 4' wide 2 hgt. x 3' wide Neon Flash Spiraea Spiraea japonica 'Neon Flash' 2' hgt. x 3' wide 5' hgt. x 5' wide 12" hgt. x 2' wide Stella De Oro Daylilly Hemerocallis x 'Stella De Oro'18" hgt. x 2' wideHH Buxus x 'Green Gem' Green Gem Boxwood 2 Gal.3' hgt. x 3' wideBM 45' hgt. x 30' wide MATURE SIZE 2 Gal.JH Blue Chip Juniper Juniperus horizontalis 'Blue Chip'6" hgt. x 6' wide 2 Gal.Rosa 'Meigalpio' #17877 Red Drift Groundcover Rose 18" hgt. x 3' wideRR Autumn Blaze Maple Shademaster Honeylocust 2" B&BAFAcer x freemanii 'Jeffersred' Gleditsia triacanthos inermis 'Shademaster' Calamagrostis x acutiflora 'Karl Forester' Karl Forester Grass CA 2 Gal.3' hgt. x 2' wide Class 1 Class II35' hgt. x 25' wide Width of street buffer: W.Nelis Drive:30 ft. Lineal feet of street buffer landscape frontage: W.Nelis Drive:180.0 lineal ft. 5 trees required 5 trees proposed Residential Subdivision Trees: N/A Acreage dedicated for Common Open Space: N/A Number of trees provided on Common Lot(s):N/A Mitigation for removal of existing trees:N/A PK Kankakee Plum Prunus cerasifera 'Kankakee'2" B&B 20' hgt x 20' wide Little Bunny Dwarf Fountain Grass Pennisetum alopecuroides 'Little Bunny'2' hgt. x 3' wide 12" hgt. x 18" wide1 Gal. @ 36" O.C. 1 Gal. @ 36" O.C. 6' Hgt.10' hgt. x 3' wide Coreopsis verticillata 'Moonbeam' Moonbeam Threadleaf Tickseed Geranium sanguineum 'Max Frei' Max Frei Bloody Cranesbill 12" hgt. x 12" wide1 Gal. @ 24" O.C. Juniperus scopulorum 'Medora' Medora Juniper PA CV GS MJ 1 Gal. @ 36" O.C. 1 Gal. @ 36" O.C. Columnar Norway Maple 2" B&BACAcer platanoides 'Columnar'Class II35' hgt. x 15' wide I-LBASE ZONING DISTRICT: 3.93 ACRESTOTAL SITE AREA: PROPERTY DESCRIPTION: LOT 05 BLK 02 MCNELIS SUB PARCEL #: R5629430160 ADDRESS: 3410 W. NELIS DRIVE MERIDIAN, ID 83642 OWNER: MCNELIS EDWARD J. Deborah Norway Maple 2" B&BAPAcer platanoides 'Deborah'Class II35' hgt. x 25' wide Class 1PS Spire Cherry Prunus x hillieri 'Sprite'2" B&B 25' hgt x 10' wide 37,057 SF.TOTAL BUILDING AREA: 22,627 SF. (21%)TOTAL LANDSCAPE AREA: SHEET NUMBER JOB NO: DATE: DRAWN BY: 21109 4-19-2021 JDRNORTHWEST SPECIALTY BEVERAGE CO.3410 W NELIS DRMERIDIAN , IDAHO 83646COPYRIGHT ALL RIGHTS RESERVED. THIS DRAWING AND ALL INFO. CONTAINED HEREIN, IS THE PROPERTY OF ARCHITECTURE DESIGNS PLUS P.A., AND MAY NOT BE REUSED WITHOUT THE WRITTEN PERMISSION OF THE ARCHITECT Apr 19, 2021 - 1:54 pmNEW FACILITY FOR:ADP ARCHITECTSLANDSCAPE PLANFO S C A P E ARCHITECTDNAL DESNECIL ETATS IDA H OD.HOJ OTER RN S LA - 16827South Landscape Architecture P.C.Dba South Beck & Baird Landscape Architecture P.C.2002 S. Vista Avesla@slaboise.comBoise, ID. 83705www.slaboise.com208.342.2999 Office01/19/2020 P U R P O S E S C O N S T R U C T I O N PRELIMINARY N O T F O R L1.0 SHEET NUMBER JOB NO: DATE: DRAWN BY: 21109 4-19-2021 JDRNORTHWEST SPECIALTY BEVERAGE CO.3410 W NELIS DRMERIDIAN , IDAHO 83646COPYRIGHT ALL RIGHTS RESERVED. THIS DRAWING AND ALL INFO. CONTAINED HEREIN, IS THE PROPERTY OF ARCHITECTURE DESIGNS PLUS P.A., AND MAY NOT BE REUSED WITHOUT THE WRITTEN PERMISSION OF THE ARCHITECT Apr 19, 2021 - 1:54 pmNEW FACILITY FOR:ADP ARCHITECTSLANDSCAPE PLANSHRUB PLANTING NOT TO SCALE 1.WATER SHRUB TWICE WITHIN FIRST 24 HOURS. 2.APPLY SPECIFIED PRE-EMERGENT PER MANUFACTURER'S RECOMMENDATIONS TO ALL GROUNDCOVER BEDS. KEEP GROUND LINE SAME AS NURSERY LINE REMOVE ANY PLASTIC, BURLAP, NAILS, OR OTHER MATERIALS FROM THE ROOTBALL WHICH MAY LIMIT ROOT GROWTH CONSTRUCT 2" EARTH BERM TO FORM A WATER RETENTION BASIN, FILL BERM WITH MULCH, AS SPECIFIED MULCH, PER PLANS, 3" DEPTH OVER ENTIRE BED. DO NOT COVER CROWNS OF PLANTS PROVIDE DEWITT PRO 5 WEED BARRIER FABRIC OR APPROVED EQUAL PROVIDE COMMERCIAL FERTILIZER TABLETS AND BIOSTIMULANT, AS SPECIFIED, FOR EACH SHRUB BACKFILL WITH APPROVED TOPSOIL AND SOIL AMENDMENTS, AS SPECIFIED. BACKFILL IN 6" LIFTS, WATER EACH LAYER, DO NOT TAMP OR OVER COMPACT. CONSTRUCT 6" MOUND OF TOPSOIL6"6" WIDTH OF ROOTBALL 6" 2 'B''A ' 'A''A''A' PERENNIAL & GROUNDCOVER PLANTING NOT TO SCALE 1.ALL GROUNDCOVER PLANTS TO BE PLANTED ON CENTER AND IN A TRIANGULAR PATTERN. 2.APPLY SPECIFIED PRE-EMERGENT PER MANUFACTURER'S RECOMMENDATIONS TO ALL GROUNDCOVER BEDS. FINISH GRADE PER PLANS EDGING, PER PLANS AND DETAILS GROUNDCOVER PLANTING PER PLANTING PLAN MULCH, PER PLANS, 3" DEPTH OVER ENTIRE BED. DO NOT COVER CROWNS OF PLANTS SPLIT ALL ROOT BOUND ROOTS WITH 3 EQUAL SPACED VERTICAL CUTS. TILL SOIL TO A DEPTH OF 12", BACKFILL WITH APPROVED TOPSOIL AND SOIL AMENDMENTS, AS SPECIFIED. DEWITT PRO 5 WEED BARRIER FABRIC OR APPROVED EQUAL SUBGRADE A = LENGTH, AS SPECIFIED OR PER PLANT SCHEDULE B = 85% OF 'A'3"12"1 APPROVED TOPSOIL AND SOIL AMENDMENTS AS SPECIFIED 3" DEPTH OF MULCH AT PLANTER BEDS CUT EDGEFINISH GRADE, PER PLANS (TYPICAL AT TREES IN TURF AREAS) PLANTER BED CUT EDGE NOT TO SCALE3 6"112"2"HIGHEST ROOT SHALL BE 2" MAXIMUM BELOW SOIL LINE. UTILIZE SOIL/ROOT PROBE AROUND TRUNK (APPROX 1"-2" AWAY FROM TRUNK) TO LOCATE HIGHEST ROOTS. SOIL LINE ROOT FLARE/COLLAR (SWELLING AT SOIL LINE WHERE STEM TISSUE TRANSITIONS INTO ROOT TISSUE) TO BE AT SOIL LINE. ROOT PROBE WHEN PRESENT: BUD POINT (A MINOR CROOK IN THE TRUNK JUST ABOVE THE SOIL LINE) TO BE APPROXIMATELY 1 12" ABOVE THE SOIL LINE 1.THE STAKING OF TREES IS TO BE THE CONTRACTOR'S OPTION; HOWEVER, THE CONTRACTOR IS RESPONSIBLE TO INSURE THAT ALL TREES ARE PLANTED STRAIGHT AND THAT THEY REMAIN STRAIGHT FOR LENGTH OF WARRANTY PERIOD OR 1 YEAR AFTER SUBSTANTIAL COMPLETION WHICHEVER IS GREATER. ALL STAKING SHALL BE REMOVED AT THE END OF THE WARRANTY PERIOD. 2.IN THE EVENT OF A QUESTION OR LACK OF CLARITY ON THE DRAWINGS, THE CONTRACTOR IS TO NOTIFY THE LANDSCAPE ARCHITECT BEFORE PROCEEDING. 3.LANDSCAPE CONTRACTOR IS TO NOTIFY THE LANDSCAPE ARCHITECT AND OWNER PRIOR TO INSTALLATION OF PLANT MATERIAL. 4.WRAP RUBBER CINCH TIES AROUND THE TREE TRUNKS AND STAKES USING EITHER THE STANDARD OR FIGURE EIGHT TYING METHOD. SECURE THE TIES TO THE STAKES WITH GALVANIZED NAILS TO PREVENT SLIPPAGE. 5.WATER TREE TWICE WITHIN THE FIRST 24 HOURS. 6.IN THE EVENT HARDPAN SOILS PREVENT TREE PLANTING AS DETAILED, NOTIFY THE LANDSCAPE ARCHITECT IMMEDIATELY. 7.FOR TREES LOCATED WITHIN ROADSIDE PLANTERS LESS THAN 8'-0" IN WIDTH, PROVIDE TREE ROOT BARRIER (DEEPROOT #24-2 OR APPROVED EQUAL). LOCATE ROOT BARRIER AT BACK OF CURB AND EDGE OF SIDEWALK. EXTEND ROOT BARRIER TO 80% OF MATURE TREE CANOPY. ALL TREE INSTALLATIONS SHALL CONFORM TO ALL AGENCY APPROVAL REQUIREMENTS, CONTRACTOR SHALL VERIFY PRIOR TO ANY INSTALLATIONS. REMOVE DEAD/DAMAGED BRANCHES AND PRUNE TO INTERNATIONAL SOCIETY OF ARBORICULTURE STANDARDS; IMPROPERLY PRUNED TREES (AS DETERMINED BY THE LANDSCAPE ARCHITECT) SHALL BE REMOVED AND REPLACED. DO NOT REMOVE MAIN LEADER!! RUBBER CINCH TIE 2"x 2" WOOD STAKE (LENGTH AS REQUIRED)-DO NOT PENETRATE ROOTBALL. SEE NOTE 1. SET STAKES PARALLEL TO PREVAILING WIND. REMOVE TREE WRAP TRUNK PROTECTION, AFTER INSTALLATION CONSTRUCT 2" EARTH BERM AT EDGE OF ROOTBALL, FILL TREE RING W/ MULCH, AS SPECIFIED. 3" THICK MULCH LAYER, KEEP MULCH 3" AWAY FROM TRUNK. REMOVE BURLAP, TWINE, AND WIRE BASKET FROM TOP 2 3 OF ROOTBALL, REMOVE ALL NAILS, TIES, AND PLASTIC FROM ROOTBALL. IF SYNTHETIC BURLAP IS UTILIZED TO WRAP THE ROOTBALL, IT SHALL BE COMPLETELY REMOVED. ONLY BIODEGRADABLE BURLAP SHALL BE LEFT ON THE BOTTOM OF THE ROOTBALL. FINISH GRADE PREVAILING WIND DIRECTION DECIDUOUS TREE PLANTING NOT TO SCALE5' MIN.CLEARASSPECIFIEDTO BASEOF CROWN5' MIN. DIA. TREE RING WIDTH OF BALL WIDTH OF BALL WIDTH OF BALL WIDTH OF BALL WIDTH OF BALL COMMERCIAL SLOW RELEASE FERTILIZER TABLETS SIDES OF HOLE ROUGH & UNEVEN BACKFILL WITH APPROVED TOPSOIL AND SOIL AMENDMENTS AS SPECIFIED. BACKFILL IN 6" LIFTS, WATER EACH LAYER, TAMP LIGHTLY AS REQUIRED, BACKFILL SOIL EVEN W/ TOP OF ROOTBALL, DO NOT OVER COMPACT!! SET ROOTBALL ON NATIVE, UNDISTURBED SOIL 4 1.CONTRACTOR TO VERIFY THE LOCATIONS OF ALL UTILITIES WITH OWNER AND UTILITY COMPANIES PRIOR TO CONSTRUCTION, TO DETERMINE IN THE FIELD ACTUAL LOCATIONS AND ELEVATIONS OF ALL EXISTING UTILITIES, WHETHER SHOWN ON THE PLANS OR NOT. THE CONTRACTOR SHALL CALL UTILITY PROTECTION SERVICE 72 HOURS PRIOR TO CONSTRUCTION. 2.CONTRACTOR SHALL EXAMINE FINISH SURFACE, GRADES, TOPSOIL QUALITY AND DEPTH. DO NOT START ANY WORK UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. VERIFY LIMITS OF WORK BEFORE STARTING. 3.CONTRACTOR TO REPORT ALL DAMAGES TO EXISTING CONDITIONS AND INCONSISTENCIES WITH PLANS TO OWNER'S REPRESENTATIVE PRIOR TO BEGINNING OF CONSTRUCTION. 4.CONTRACTOR SHALL MAINTAIN POSITIVE DRAINAGE IN ALL LANDSCAPE BEDS AND ALL LAWN AREAS. 5.CONTRACTOR TO FINE GRADE AND ROCK HOUND ALL PLANTING AREAS PRIOR TO PLANTING, TO PROVIDE A SMOOTH AND CONTINUOUS SURFACE, FREE OF IRREGULARITIES (BUMPS OR DEPRESSIONS) AND EXTRANEOUS MATERIAL OR DEBRIS. 6.COORDINATE LANDSCAPE INSTALLATION WITH INSTALLATION OF UNDERGROUND SPRINKLER AND DRAINAGE SYSTEMS. 7.CONTRACTOR SHALL OBTAIN WRITTEN APPROVAL FOR ALL PLANT MATERIAL SUBSTITUTIONS FROM OWNER'S REPRESENTATIVE PRIOR TO ORDERING OR INSTALLATION. FAILURE TO COMPLY WILL REQUIRE THE REMOVAL OF MATERIALS AT NO COST TO THE OWNER AND REPLACED WITH APPROVED MATERIALS. 8.CONTRACTOR SHALL BE RESPONSIBLE TO IMPLEMENT BEST MANAGEMENT PRACTICES TO STABILIZE ALL SLOPES 3:1 OR GREATER AND PREVENT EROSION OR MOVEMENT OF SOIL FROM SLOPES. 9.ALL ROCK MATERIALS TO BE OBTAINED FROM LOCAL SOURCE OR APPROVED EQUAL. GENERAL NOTES 1.ALL AREAS TO BE PLANTED OR HYDROSEEDED SHALL HAVE WEED ABATEMENT OPERATIONS PERFORMED ON THEM PRIOR TO PLANTING OR HYDROSEEDING. 2.CONTRACTOR SHALL SPRAY ALL EXPOSED WEEDS WITH 'ROUND-UP' (CONTACT HERBICIDE) OR APPROVED EQUAL. 3.DO NOT WATER FOR AT LEAST SEVEN (7) DAYS. REMOVE EXPOSED WEEDS FROM THE SITE. 4.CONTRACTOR SHALL OPERATE THE AUTOMATIC IRRIGATION SYSTEM FOR A PERIOD OF FOURTEEN (14) DAYS. AT CONCLUSION OF THIS WATERING PERIOD, DISCONTINUE WATERING FOR THREE TO FIVE (3-5) DAYS. 5.APPLY SECOND APPLICATION OF 'ROUND-UP' TO ALL EXPOSED WEEDS. APPLY IN STRICT CONFORMANCE WITH MANUFACTURER'S SPECIFICATIONS AND INSTRUCTIONS. DO NOT WATER FOR AT LEAST SEVEN (7) DAYS. REMOVE WEEDS FROM THE SITE. 6.IF ANY EVIDENCE OF WEED GERMINATION EXISTS AFTER TWO (2) APPLICATIONS, CONTRACTOR SHALL BE DIRECTED TO PERFORM A THIRD APPLICATION. 7.AT THE TIME OF PLANTING AND HYDROSEEDING, ALL PLANTING AREAS SHALL BE WEED FREE. 8.COORDINATE WITH CIVIL FOR ALL WEED ABATEMENT REQUIREMENTS WEED ABATEMENT 1.COORDINATE ALL DRAINAGE AREAS AND UTILITIES WITH TREE LOCATIONS AND ADJUST PER FIELD CONDITIONS. 2.TREES SHALL NOT BE PLANTED WITHIN THE 10'-0" CLEAR ZONE OF ALL STORM DRAIN PIPE, STRUCTURES, OR FACILITIES. 3.ANY PERENNIAL TREES OR PLANTS THAT WILL EXTEND ROOTS DEEPER THAN 18" SHALL BE PROHIBITED OVER UNDERGROUND SEEPAGE BEDS, INFILTRATION FACILITIES OR PIPING SYSTEMS. 4.SEEPAGE BEDS AND OTHER STORM DRAINAGE FACILITIES MUST BE PROTECTED FROM ANY AND ALL CONTAMINATION DURING THE CONSTRUCTION AND INSTALLATION OF THE LANDSCAPE IRRIGATION SYSTEM. 5.ALL TREES TO BE LOCATED A MINIMUM OF 5 FEET OR GREATER FROM THE BACK OF ANY SIDEWALK. 6.TRIM ALL TREES WITHIN VISION TRIANGLES TO 8' ABOVE FINISH GRADE TO MEET LOCAL JURISDICTIONAL STANDARDS. RIGHT OF WAY LANDSCAPE NOTES 1.TOPSOIL REQUIREMENTS: ASTM D 5268, PH RANGE OF 5.5 TO 7, FOUR PERCENT ORGANIC MATERIAL MINIMUM, FREE OF STONES 1/2 INCH OR LARGER IN ANY DIMENSION, AND OTHER EXTRANEOUS MATERIALS HARMFUL TO PLANT GROWTH. 2.TOPSOIL SOURCE: REUSE EXISTING TOPSOIL STOCKPILED ON THE SITE. SUPPLEMENT WITH IMPORTED TOPSOIL WHEN QUANTITIES ARE INSUFFICIENT. VERIFY SUITABILITY AND CONDITION OF TOPSOIL AS A GROWING MEDIUM. A.STRIP EXISTING TOPSOIL FROM ALL AREAS OF THE SITE TO BE DISTURBED. TOPSOIL SHALL BE FERTILE, FRIABLE, NATURAL LOAM, SURFACE SOIL, REASONABLY FREE OF SUBSOIL, CLAY LUMPS, BRUSH, WEEDS AND OTHER LITTER, AND FREE OF ROOTS, STUMPS, ORGANIC MATTER LARGER THAN 1/2 INCHES IN ANY DIMENSION, AND OTHER EXTRANEOUS OR TOXIC MATTER HARMFUL TO PLANT GROWTH. TOPSOIL SHALL BE SCREENED TO ACHIEVE THIS REQUIREMENT. 3.REPRESENTATIVE SAMPLES OF PLANTING SOILS SHALL BE TESTED FOR ACIDITY, FERTILITY, ORGANIC MATTER AND GENERAL TEXTURE BY A RECOGNIZED COMMERCIAL OR GOVERNMENT AGENCY. SUBMIT TOPSOIL ANALYSIS TEST RESULTS FROM TESTING LABORATORY WITH RECOMMENDATIONS FOR IT TO MEET REQUIREMENTS.TO THE LANDSCAPE ARCHITECT'S REPRESENTATIVE BY THE CONTRACTOR. ALL TOPSOIL SHALL BE AMENDED TO ACHIEVE SPECIFIED PH AND ORGANIC REQUIREMENTS. RE-TEST TOPSOIL PRIOR TO FINAL COMPLETION TO ENSURE REQUIREMENTS HAVE BEEN MET. 4.AT A MINIMUM, PREPARE SOIL IN ALL AREAS BY SPREADING A 15-15-15 FERTILIZER AT 7.5 POUNDS PER 1000 SQUARE FEET OF SURFACE AREA AND AN MANURE COMPOST (OR APPROVED EQUAL) AT 3 CUBIC YARDS PER 1000 SQUARE FEET OF SURFACE AREA OVER FINISH GRADE AND ROTO-TILL INTO TOP 6" OF SOIL. FOLLOW ALL IMPROVEMENT RECOMMENDATIONS OF SOIL TEST RESULTS. TOPSOIL SHALL BE A LOOSE, FRIABLE, SANDY LOAM, CLEAN AND FREE OF TOXIC MATERIALS, NOXIOUS WEEDS, WEED SEEDS, ROCKS, GRASS OR OTHER FOREIGN MATERIAL AND A HAVE A PH OF 5.5 TO 7.0. IF ONSITE TOPSOIL DOES NOT MEET THESE MINIMUM STANDARDS, CONTRACTOR IS RESPONSIBLE TO EITHER: A.PROVIDE APPROVED IMPORTED TOPSOIL, OR B.IMPROVE ON-SITE TOPSOIL WITH METHODS APPROVED BY THE LANDSCAPE ARCHITECT. 5.IF IMPORTED TOPSOIL FROM OFF-SITE SOURCES IS REQUIRED, ENSURE IT IS FERTILE, FRIABLE, NATURAL LOAM, SURFACE SOIL, REASONABLY FREE OF SUBSOIL, CLAY LUMPS, BRUSH, WEEDS AND OTHER LITTER, AND FREE OF ROOTS, STUMPS, STONES LARGER THAN 2 INCHES IN ANY DIMENSION, AND OTHER EXTRANEOUS OR TOXIC MATTER HARMFUL TO PLANT GROWTH. A.OBTAIN TOPSOIL FROM LOCAL SOURCES OR FROM AREAS HAVING SIMILAR SOIL CHARACTERISTICS TO THOSE FOUND ON THE PROJECT SITE. OBTAIN TOPSOIL ONLY FROM NATURALLY, WELL-DRAINED SITES WHERE TOPSOIL OCCURS AT A DEPTH OF NOT LESS THAN 4 INCHES. B.REPRESENTATIVE SAMPLES SHALL BE TESTED FOR ACIDITY, FERTILITY, TOXICITY, ORGANIC MATTER, AND GENERAL TEXTURE BY A RECOGNIZED COMMERCIAL OR GOVERNMENT AGENCY AND COPIES OF THE TESTING AGENCY'S FINDINGS AND RECOMMENDATIONS SHALL BE FURNISHED TO THE OWNER'S REPRESENTATIVE BY THE CONTRACTOR. NO TOPSOIL SHALL BE DELIVERED IN A FROZEN OR MUDDY CONDITION. ACIDITY/ALKALINITY RANGE - PH. 5.5 TO 7.6. 6.NO TOPSOIL SHALL BE PLACED WHILE IN A FROZEN OR MUDDY CONDITION. 7.PLACE TOPSOIL IN AREAS WHERE REQUIRED TO OBTAIN THICKNESS AS SCHEDULED. PLACE TOPSOIL DURING DRY WEATHER. PROVIDE ADDITIONAL IMPORTED TOPSOIL REQUIRED TO BRING SURFACE TO PROPOSED FINISH GRADE, AS REQUIRED. 8.IMMEDIATELY CLEAN UP ANY TOPSOIL OR OTHER DEBRIS ON THE SITE CREATED FROM LANDSCAPE OPERATIONS AND DISPOSE OF PROPERLY OFF SITE. 9.TOPSOIL STOCKPILE LOCATIONS TO BE COVERED COORDINATE WITH EROSION AND SEDIMENT CONTROL PLAN. 10.ALL GRAVEL, SUBBASE, AND OTHER IMPORTED FILL MATERIALS OTHER THAN TOPSOIL SHALL ONLY BE STOCKPILED IN PROPOSED IMPERVIOUS AREAS. NO GRAVEL OR ROCK MATERIALS SHALL BE STOCKPILED OR TEMPORARILY PLACED IN PROPOSED LANDSCAPE AREAS TO PREVENT LANDSCAPE AREAS FROM BEING CONTAMINATED WITH ROCK MATERIALS. CONTRACTOR SHALL SUBMIT A DETAILED STOCKPILE PLAN TO LANDSCAPE ARCHITECT AND OWNER FOR APPROVAL PRIOR TO ANY EARTHWORK OPERATIONS. PLANTING SOIL NOTES 1.SEE CIVIL ENGINEERING PLANS FOR ALL SITE CLEARING AND ROUGH GRADE WORK. FINISH GRADE 1" OF DESIGN GRADE. COORDINATE ALL LANDSCAPE WORK WITH CIVIL DRAWINGS. SEE ARCHITECTURAL SITE PLAN FOR ALL SITE ELEMENTS NOT SHOWN ON LANDSCAPE PLAN. 2.COORDINATE ALL WORK WITH ALL OTHER SITE RELATED DEVELOPMENT DRAWINGS. 3.COORDINATE WORK SCHEDULE AND OBSERVATIONS WITH LANDSCAPE ARCHITECT PRIOR TO CONSTRUCTION START-UP IR REQUIRED BY OWNER. 4.CONTRACTOR SHALL REPORT TO OWNER'S REPRESENTATIVE ALL CONDITIONS WHICH IMPAIR AND/OR PREVENT THE PROPER EXECUTION OF THIS WORK PRIOR TO BEGINNING WORK. COORDINATE WORK SCHEDULE AND OBSERVATIONS PRIOR TO CONSTRUCTION STARTUP. 5.BEFORE PROCEEDING WITH WORK, CHECK AND VERIFY DIMENSIONS AND QUANTITIES. REPORT VARIATIONS BETWEEN DRAWINGS AND SITE TO OWNER'S REPRESENTATIVE BEFORE PROCEEDING WITH WORK. 6.ALL PLANT MATERIAL SHALL CONFORM TO ANSI Z60.1 - "AMERICAN STANDARD FOR NURSERY STOCK". ACCEPTANCE OF PLANT MATERIAL SHALL BE SUBJECT TO APPROVAL OF OWNER'S REPRESENTATIVE. PLANT MATERIAL SHALL BE PROVIDED BY LICENSED NURSERY OR WHOLESALE GROWER. NO BARE ROOT STOCK ALLOWED. SEE DETAILS FOR FURTHER PLANTING REQUIREMENTS. 7.NO MATERIAL SUBSTITUTIONS SHALL BE MADE WITHOUT THE LANDSCAPE ARCHITECT'S PRIOR WRITTEN APPROVAL. ALTERNATE MATERIALS OF SIMILAR SIZE AND CHARACTER MAY BE CONSIDERED IF SPECIFIED PLANT MATERIALS CAN NOT BE OBTAINED. 8.IN THE EVENT OF A PLANT COUNT DISCREPANCY, PLANT SYMBOLS SHALL OVERRIDE SCHEDULE QUANTITIES AND CALL OUT SYMBOL NUMBERS. 9.FINISH GRADES SHALL PROVIDE A SMOOTH TRANSITION WITH ADJACENT SURFACES AND ENSURE POSITIVE DRAINAGE IN ACCORDANCE WITH THE SITE GRADING PLAN. 10.PLANT ALL TREES AND SHRUBS PER DETAILS. USE APPROVED PLANTING SOIL AS SPECIFIED IN PLANTING SOIL NOTES OR APPROVED EQUAL. USE WHEN BACK FILLING TREE AND SHRUB PITS. 11.WATER PLANTS THOROUGHLY AFTER PLANTING. 12.REPLACE ALL PLANT MATERIAL FOUND DEAD OR NOT IN A HEALTHY CONDITION IMMEDIATELY WITH THE SAME SIZE AND TYPE AT NO COST TO OWNER. CONTRACTOR TO GUARANTEE ALL PLANT MATERIAL FOR ONE YEAR AFTER SUBSTANTIAL COMPLETION HAS BEEN CERTIFIED BY OWNER'S REPRESENTATIVE. PLANTS NOT IN A HEALTHY GROWING CONDITION AFTER ONE (1) YEAR SHALL BE REPLACED AT NO COST TO OWNER EXCEPT FOR LOSS DUE TO CONDITIONS BEYOND THE CONTROL OF THE CONTRACTOR. INSPECTION AND ACCEPTANCE TO BE DONE BY OWNER'S REPRESENTATIVE. 13.LIMIT SUBGRADE PREPARATION TO AREAS TO BE PLANTED. 14.NEWLY GRADED SUBGRADES: LOOSEN SUBGRADE TO A MINIMUM DEPTH OF 4 INCHES. REMOVE STONES LARGER THAN 1 INCH IN ANY DIMENSION AND STICKS, ROOTS, RUBBISH, AND OTHER EXTRANEOUS MATTER AND LEGALLY DISPOSE OF THEM OFF OWNER'S PROPERTY. A.SPREAD PLANTING SOIL TO A COMPACTED DEPTH OF 12 INCHES IN TURF AREAS AND 18 INCHES AT SHRUB BED AREAS BUT NOT LESS THAN REQUIRED TO MEET FINISH GRADES AFTER LIGHT ROLLING AND NATURAL SETTLEMENT. DO NOT SPREAD IF PLANTING SOIL OR SUBGRADE IS FROZEN, MUDDY, OR EXCESSIVELY WET. B.SPREAD PLANTING SOIL OVER LOOSENED SUBGRADE. C.REDUCE ELEVATION OF PLANTING SOIL TO ALLOW FOR SOIL THICKNESS OF SOD OR SEED. 16.UNCHANGED SUBGRADES: IF TURF OR SHRUBS ARE TO BE PLANTED IN AREAS UNALTERED OR UNDISTURBED BY EXCAVATING, GRADING, OR SURFACE-SOIL STRIPPING OPERATIONS, PREPARE SURFACE SOIL AS FOLLOWS: D.REMOVE EXISTING GRASS, VEGETATION, AND TURF. DO NOT MIX INTO SURFACE SOIL. E.LOOSEN SURFACE SOIL TO A DEPTH OF AT LEAST 6 INCHES. PROVIDE WEED ABATEMENT PROCEDURE. APPLY SOIL AMENDMENTS AND FERTILIZERS ACCORDING PLANTING SOIL NOTES AND MIX THOROUGHLY INTO TOP 6 INCHES OF SOIL. TILL SOIL TO A HOMOGENEOUS MIXTURE OF FINE TEXTURE. F.LEGALLY DISPOSE OF WASTE MATERIAL, INCLUDING GRASS, VEGETATION, AND TURF, OFF OWNER'S PROPERTY. 17.FINISH GRADING: GRADE PLANTING AREAS TO A SMOOTH, UNIFORM SURFACE PLANE WITH LOOSE, UNIFORMLY FINE TEXTURE. GRADE TO WITHIN PLUS OR MINUS 1/2 INCH OF FINISH ELEVATION. ROLL AND RAKE, REMOVE RIDGES, AND FILL DEPRESSIONS TO MEET FINISH GRADES. LIMIT FINISH GRADING TO AREAS THAT CAN BE PLANTED IN THE IMMEDIATE FUTURE.SPREAD, COMPACT, AND FINE GRADE TOPSOIL TO A SMOOTH AND UNIFORM GRADE 3" BELOW ADJACENT SURFACES OF PLANTER BED AREAS, 1-1/2" BELOW ADJACENT SURFACES OF TURF SOD AREAS, AND 1" BELOW ADJACENT SURFACES OF TURF SEED AREAS. 18.MOISTEN PREPARED AREA BEFORE PLANTING IF SOIL IS DRY. WATER THOROUGHLY AND ALLOW SURFACE TO DRY BEFORE PLANTING. DO NOT CREATE MUDDY SOIL. 19.BEFORE PLANTING, OBTAIN LANDSCAPE ARCHITECT'S ACCEPTANCE OF FINISH GRADING; RESTORE PLANTING AREAS IF ERODED OR OTHERWISE DISTURBED AFTER FINISH GRADING. 20.DO NOT SOW IMMEDIATELY FOLLOWING RAIN, OR WHEN GROUND IS TOO DRY. TEMPERATURE SHALL BE BETWEEN 55 F AND 95 F FOR A 24 HOUR PERIOD. WIND SHALL BE LESS THAN 5 MPH. 21.MAINTAIN ALL LANDSCAPING FOR 30 DAYS AFTER COMPLETION OF LANDSCAPING OR UNTIL SUBSTANTIAL COMPLETION, WHICHEVER IS LATER. THIS WILL INCLUDE WATERING, MOWING, AND REPLACING LAWN THAT IS NOT IN A HEALTHY GROWING STATE. 22.BEGIN PLANTING ONLY AFTER INSTALLATION AND ACCEPTANCE OF THE AUTOMATIC UNDERGROUND SPRINKLER SYSTEM AND ACCEPTANCE OF FINISH GRADING BY OWNER'S REPRESENTATIVE. 23.THE FOLLOWING LANDSCAPE INSPECTIONS SHALL BE MADE BY THE OWNER'S REPRESENTATIVE AFTER AT LEAST 48 HOURS NOTICE HAS BEEN GIVEN BY THE CONTRACTOR: A.AFTER GRADING HAS BEEN COMPLETED AND BEFORE IRRIGATION HAS BEEN INSTALLED. B.AFTER INSTALLING THE IRRIGATION MAINLINE. C.AFTER IRRIGATION HAS BEEN COMPLETED AND BEFORE PLANTING HAS BEEN INSTALLED. D.AFTER COMPLETION OF THE INSTALLATION OF ALL PLANT MATERIALS. E.AFTER ALL WORK HAS BEEN COMPLETED (SUBSTANTIAL COMPLETION). 19.ALL PLANTING BED AREAS SHALL BE COVERED IN A MINIMUM OF 3" DEPTH OF 1" BARK MULCH, INSTALL PER MANUFACTURER'S RECOMMENDATIONS. SUBMIT SAMPLE OF MULCH MATERIAL FOR APPROVAL BY OWNER'S REPRESENTATIVE. 20.AGRIFORM TABLETS(20-10-5) ARE TO BE ADDED TO THE PLANTED MATERIALS IN THE FOLLOWING QUANTITIES: 1 PER 1 GALLON SHRUB, 2 PER 2 OR 3 GALLON SHRUB, 3 PER 5 GALLON SHRUB, AND 6 PER TREE. DISTRIBUTE EQUALLY IN ROOT ZONE OF EACH PLANT. 21.AFTER PLANTING, APPLY PRE-EMERGENT(ELANCO, XL, RONSTAR, SURFLAN, OR APPROVED EQUAL) PRIOR TO APPLICATION OF MULCH. 22.UPON COMPLETION OF PLANTING OPERATION, CLEAR SITE OF DEBRIS, SUPERFLUOUS MATERIALS AND EQUIPMENT, ALL OF WHICH SHALL BE ENTIRELY REMOVED FROM PREMISES. IMMEDIATELY CLEAN UP ANY TOPSOIL OR OTHER DEBRIS ON THE SITE CREATED FROM LANDSCAPE OR IRRIGATION ACTIVITIES AND PROPERLY DISPOSE OF OFF SITE. 23.PROVIDE WRITTEN INSTRUCTIONS ON MAINTENANCE REQUIREMENTS TO OWNER. 24.MAINTAIN TREES BY PRUNING, CULTIVATION AND WEEDING AS REQUIRED FOR HEALTHY GROWTH. TIGHTEN AND REPAIR STAKE AND GUY SUPPORTS AND RESET TREES TO PROPER GRADES OR VERTICAL POSITIONS AS REQUIRED. SPRAY AS REQUIRED TO KEEP TREES FREE OF INSECTS AND DISEASE. 25.ALL PLANTING AREAS TO BE SEPARATED FROM ALL LAWN AREAS WITH APPROVED LANDSCAPE EDGING PER PLANS - SEE DETAIL. 26.ALL TREES TO BE LOCATED A MINIMUM OF 5 FEET OR GREATER FROM THE BACK OF ANY SIDEWALK. 27.IN THE EVENT OF A DISCREPANCY, NOTIFY THE LANDSCAPE ARCHITECT IMMEDIATELY. LANDSCAPE SPECIFICATIONS THIS DRAWING HAS BEEN PREPARED BASED UPON INFORMATION PROVIDED, IN PART BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, SOUTH BECK AND BAIRD, PC. CANNOT ASSURE ITS ACCURACY AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THIS DRAWING OR FOR ANY ERRORS OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATE INTO IT AS A RESULT. SOUTH BECK AND BAIRD, PC. ASSUMES NO LIABILITY FOR ANY MISINFORMATION. DISCLAIMER BOULDER INSTALLATION NOT TO SCALE 1. NOTIFY LANDSCAPE ARCHITECT WHEN PLACING BOULDERS FOR APPROVAL. 2. PLACE BOULDERS PRIOR TO INSTALLATION OF IRRIGATION. 3. CLEAN BOULDERS OF SOIL AND LOOSE DEBRIS. 4. WHEN PLACING BOULDERS, BURY 1 4 TO 1 3 OF BOULDER BELOW FINISH GRADE. 5. DO NOT SCAR OR DAMAGE BOULDERS. 6. WHEN GROUPING BOULDERS, DISTRIBUTE SIZES EVENLY (I.E., IN A GROUP OF (6), (2) WILL BE LARGE, (2) WILL BE MEDIUM, AND (2) WILL BE SMALL). 1/3 1/3 of Stone Height1/3 VARY HEIGHTS OF BOULDERS. 18" - 36" DIAMETER BOULDER, AS SPECIFIED, LOCATE PER PLANS 30" - 60" DIAMETER BOULDER, AS SPECIFIED, COMPACT SUBGRADE UNDER BOULDER AS REQUIRED FINISH GRADE PER PLANS 5 L2.0 FO S C A P E ARCHITECTDNAL DESNECIL ETATS IDA H OD.HOJ OTER RN S LA - 16827 01/19/2020 One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2011-2020 Acuity Brands Lighting, Inc. All rights reserved. DSX1-LED Rev. 11/16/20 Page 1 of 8COMMERCIAL OUTDOOR D-Series Size 1 LED Area Luminaire Catalog Number Notes Type Introduction The modern styling of the D-Series is striking yet unobtrusive - making a bold, progressive statement even as it blends seamlessly with its environment. The D-Series distills the benefits of the latest in LED technology into a high performance, high efficacy, long-life luminaire. The outstanding photometric performance results in sites with excellent uniformity, greater pole spacing and lower power density. It is ideal for replacing up to 750W metal halide in pedestrian and area lighting applications with typical energy savings of 65% and expected service life of over 100,000 hours. Hit the Tab key or mouse over the page to see all interactive elements. L H L H1 WW HH2 Ordering Information EXAMPLE: DSX1 LED P7 40K T3M MVOLT SPA NLTAIR2 PIRHN DDBXD DSX1 LED Series LEDs Color temperature Distribution Voltage Mounting DSX1 LED Forward optics P1 P4 1 P7 1 P2 P5 1 P8 P3 P6 1 P9 1 Rotated optics P10 2 P12 2 P11 2 P13 1,2 30K 3000 K 40K 4000 K 50K 5000 K T1S Type I short (Automotive) T2S Type II short T2M Type II medium T3S Type III short T3M Type III medium T4M Type IV medium TFTM Forward throw medium T5VS Type V very short 3 T5S Type V short 3 T5M Type V medium 3 T5W Type V wide 3 BLC Backlight control 4 LCCO Left corner cutoff 4 RCCO Right corner cutoff 4 MVOLT 5 XVOLT (277V-480V) 6,7,8 120 9 208 9 240 9 277 9 347 9 480 9 Shipped included SPA Square pole mounting RPA Round pole mounting 10 WBA Wall bracket 3 SPUMBA Square pole universal mounting adaptor 11 RPUMBA Round pole universal mounting adaptor 9 Shipped separately KMA8 DDBXD U Mast arm mounting bracket adaptor (specify finish) 12 Specifications EPA:1.01 ft2 (0.09 m2) Length:33” (83.8 cm) Width:13” (33.0 cm) Height H1:7-1/2” (19.0 cm) Height H2:3-1/2” Weight (max):27 lbs (12.2 kg) Control options Other options Finish (required) Shipped installed NLTAIR2 nLight AIR generation 2 enabled 13 PIRHN Network, high/low motion/ambient sensor 14 PER NEMA twist-lock receptacle only (controls ordered separate) 15 PER5 Five-pin receptacle only (controls ordered separate) 15,16 PER7 Seven-pin receptacle only (controls ordered separate) 15,16 DMG 0-10v dimming wires pulled outside fixture (for use with an external control, ordered separately) 17 DS Dual switching 18,19,20 PIR High/low, motion/ambient sensor, 8-15’ mounting height, ambient sensor enabled at 5fc 20,21 PIRH High/low, motion/ambient sensor, 15-30’ mounting height, ambient sensor enabled at 5fc 20,21 PIR1FC3V High/low, motion/ambient sensor, 8-15’ mounting height, ambient sensor enabled at 1fc 20,21 PIRH1FC3V Bi-level, motion/ambient sensor, 15-30’ mounting height, ambient sensor enabled at 1fc 20,21 FAO Field adjustable output 20,21 Shipped installed HS House-side shield 23 SF Single fuse (120, 277, 347V) 9 DF Double fuse (208, 240, 480V) 9 L90 Left rotated optics 2 R90 Right rotated optics 2 HA 50°C ambient operations 1 Shipped separately BS Bird spikes 24 EGS External glare shield DDBXD Dark bronze DBLXD Black DNAXD Natural aluminum DWHXD White DDBTXD Textured dark bronze DBLBXD Textured black DNATXD Textured natural aluminum DWHGXD Textured white DSXW1 LED Series LEDs Drive Current Color temperature Distribution Voltage Mounting Control Options DSXW1 LED 10C 10 LEDs (one engine) 20C 20 LEDs (two engines) 1 350 350 mA 530 530 mA 700 700 mA 1000 1000 mA (1 A) 1 30K 3000 K 40K 4000 K 50K 5000 K AMBPC Amber phosphor converted T2S Type II Short T2M Type II Medium T3S Type III Short T3M Type III Medium T4M Type IV Medium TFTM Forward Throw Medium MVOLT 2 120 3 208 3 240 3 277 3 347 3,4 480 3,4 Shipped included (blank)Surface mounting bracket BBW Surface- mounted back box (for conduit entry) 5 Shipped installed PE Photoelectric cell, button type 6 DMG 0-10v dimming wires pulled outside fixture (for use with an external control, ordered separately) PIR 180° motion/ambient light sensor, <15’ mtg ht 1,7 PIRH 180° motion/ambient light sensor, 15-30’ mtg ht 1,7 PIR1FC3V Motion/ambient sensor, 8-15' mounting height, ambient sensor enabled at 1fc 1,7 PIRH1FC3V Motion/ambient sensor, 15-30' mounting height, ambient sensor enabled at 1fc 1,7 ELCW Emergency battery backup (includes external component enclosure), CA Title 20 Noncompliant 8,9 Other Options Finish (required) Shipped installed Shipped separately 11 SF Single fuse (120, 277 or 347V) 3,10 BSW Bird-deterrent spikes DF Double fuse (208, 240 or 480V) 3,10 VG Vandal guard HS House-side shield 11 DDL Diffused drop lens SPD Separate surge protection 12 DDBXD Dark bronze DSSXD Sandstone DWHGXD Textured white DBLXD Black DDBTXD Textured dark bronze DSSTXD Textured sandstone DNAXD Natural aluminum DBLBXD Textured black DWHXD White DNATXD Textured natural aluminum One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2013-2020 Acuity Brands Lighting, Inc. All rights reserved. COMMERCIAL OUTDOOR DSXW1-LED Rev. 10/20/20 D-Series Size 1LED Wall Luminaire Ordering Information EXAMPLE: DSXW1 LED 20C 1000 40K T3M MVOLT DDBTXD NOTES 1 20C 1000 is not available with PIR, PIRH, PIR1FC3V or PIRH1FC3V. 2 MVOLT driver operates on any line voltage from 120-277V (50/60 Hz). 3 Single fuse (SF) requires 120, 277 or 347 voltage option. Double fuse (DF) requires 208, 240 or 480 voltage option. 4 Only available with 20C, 700mA or 1000mA. Not available with PIR or PIRH. 5 Back box ships installed on fixture. Cannot be field installed. Cannot be ordered as an accessory. 6 Photocontrol (PE) requires 120, 208, 240, 277 or 347 voltage option. Not available with motion/ambient light sensors (PIR or PIRH). 7 Reference Motion Sensor table on page 3. 8 Cold weather (-20C) rated. Not compatible with conduit entry applications. Not available with BBW mounting option. Not available with fusing. Not available with 347 or 480 voltage options. Emergency components located in back box housing. Emergency mode IES files located on product page at www.lithonia.com 9 Not available with SPD. 10 Not available with ELCW. 11 Also available as a separate accessory; see Accessories information. 12 Not available with ELCW. Catalog Number Notes Type Accessories Ordered and shipped separately. DSXWHS U House-side shield (one per light engine) DSXWBSW U Bird-deterrent spikes DSXW1VG U Vandal guard accessory Hit the Tab key or mouse over the page to see all interactive elements. Introduction The D-Series Wall luminaire is a stylish, fully integrated LED solution for building-mount applications. It features a sleek, modern design and is carefully engineered to provide long-lasting, energy-efficient lighting with a variety of optical and control options for customized performance. With an expected service life of over 20 years of nighttime use and up to 74% in energy savings over comparable 250W metal halide luminaires, the D-Series Wall is a reliable, low-maintenance lighting solution that produces sites that are exceptionally illuminated. Luminaire Width:13-3/4” (34.9 cm) Depth:10” (25.4 cm) Height:6-3/8” (16.2 cm) Back Box (BBW, ELCW) Width:13-3/4” (34.9 cm) Depth:4” (10.2 cm) Height:6-3/8” (16.2 cm) For 3/4” NPT side-entry conduit (BBW only) Specifications Weight: 12 lbs (5.4 kg) BBW Weight:5 lbs (2.3 kg) ELCW Weight:10 lbs (4.5 kg) D H W 413-3/4 6-3/8 FOR 3/4" NPTSIDE-ENTRY CONDUIT3-PLACES (BBW ONLY) D H 413-3/4 6-3/8 FOR 3/4" NPTSIDE-ENTRY CONDUIT3-PLACES (BBW ONLY) W