Loading...
A1-0 - ENERGY REPORT & SCHEDULES2015 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) TABLE N1102.1 INSULATION & FENESTRATION REQUIREMENT CLIMATE ZONE FENESTRATION U-FACTOR CEILING R-VALUE WOOD FRAME WALL R-VALUE MASS WALL R-VALUE FLOOR R-VALUE BASEMENT/CRAWL SPACE R-VALUE SLAB R-VALUE & DEPTH 5 0.35 R-38 R-21 13/17 30 15/19 R-10; 2FT GENERAL NOTES: 1. EXTERIOR WALLS 2x6, INTERIOR WALLS 2x4 UNLESS NOTED. DOUBLE TOP PLATE AND SINGLE BOTTOM PLATE. 2. FIELD VERIFY ALL DIMENSIONS. 3. VERIFY ALL WINDOW AND DOOR HEADER HEIGHTS WITH GENERAL CONTRACTOR. 4. WINDOW AND DOOR HEADERS TO BE 4x8 DF w/ 2X6 TOP AND BOTTOM PLATES UNDER 5'-0" SPAN. USE 4x10 w/ 2x6 TOP AND BOTTOM PLATE AS HEADERS UP TO 7'-0" SPAN w/ DOUBLE CRIPPLES. ALL LARGER SPAN HEADERS WILL BE CALLED OUT ON PLAN. 5. SHEAR PANELS ARE TO BE 7/16" OSB SHEATHING w/ MIN. 6d NAILS OR MIN 1 3/4" GAUGE STAPLES 12 o.c. FIELD NAILING AND 3" PERIMETER NAILING. SEE FOUNDATION PLAN FOR STHD14 STRAP LOCATIONS. 6. ROOF SYSTEM TO BE PRE-ENGINEERED MANUFACTURED WOOD TRUSSES. SEE TRUSS MANUFACTURER LAYOUTS AND SPECIFICATIONS FOR INSTALLATION. 7. USE TEMPERED GLAZING IN DOORS, SLIDING PATIO DOORS, STORM DOORS, SHOWER & BATH ENCLOSURES, WINDOWS WHERE NEAREST EXPOSED EDGE OF THE GLAZING IS WITHIN 48" OF A VERTICAL EDGE OF AN ACTIVE DOOR AND FIXED PANELS GREATER THAN 9 SQ FT WITH THE LOWEST EDGE LESS THAN 18" ABOVE FLOOR. 8. IN COMBUSTIBLE CONSTRUCTION, FIRE BLOCKING SHALL BE PROVIDED TO CUT OFF ALL CONCEALED DRAFT OPENINGS - BOTH VERTICAL AND HORIZONTAL - AND TO FORM AN EFFECTIVE FIRE BARRIER BETWEEN STORIES, AND BETWEEN A TOP STORY & THE ROOF SPACE. 9. IN COMBUSTIBLE CONSTRUCTION WHERE THERE IS UNUSABLE SPACE BOTH ABOVE AND BELOW THE CONCEALED SPACE OF A FLOOR/CEILING ASSEMBLY, DRAFTSTOPS SHALL BE INSTALLED SO THAT THE AREA OF THE CONCEALED SPACE DOES NOT EXCEED 1,000 SQ.FT. 10. PORTABLE FIRE EXTINGUISHERS TO BE INSTALLED IN ACCORDANCE TO NFPA 10 AND IBC SECTION 906. DOOR HARDWARE NOTES: ALL DOOR HARDWARE MUST: - ALLOW ONE-HAND OPERATION - NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST - OPERATE WITH 5 LBF MAXIMUM - BE LOCATED 34” TO 48” ABOVE THE FLOOR OR GROUND EXTERIOR/FIRE DOOR HARDWARE: HINGES WEATHER STRIPPING CLOSER PANIC BAR (INTERIOR SIDE) LEVER HANFLE EGRESS LOCK AUTOMATIC SLIDING DOORS: WEATHERSTRIPPING EGRESS LOCK MOTION SENSOR A B D E 1-HR FIRE RATED HOLLW METAL DOOR HOLLOW METAL FRAME TIMELY FRAME SOLID CORE DOOR STAINED TIMELY FRAME HOLLOW METAL DOOR POCKET TIMELY FRAME DOUBLE BARN DOORSEE SCEDULESEE SCHED. C GLASS TIMELY FRAME HOLLOW METAL DOOR T TT SEE SCHED.SEE SCHED. 24" OR LESS 24" OR LESS 5' - 0"SAFETY GLASS REQUIRED BELOW 60"SAFETY GLASS REQUIREMENTS: GLAZING IN INDIVIDUAL FIXED OR OPERABLE WHICH MEETS ALL OF THE FOLLOWING CONDITIONS: 1. EXPOSED AREA OF AN INDIVIDUAL PANEL GREATER THAN 9 SQ FT. 2. EXPOSED BOTTOM EDGE LESS THAN 18” ABOVE THE FLOOR. 3. EXPOSED TOP EDGE GREATER THAN 36” ABOVE THE FLOOR AND; 4. ONE OR MORE WALKING SURFACE(S) WITHIN 36” HORIZONTALLY OF THE PLANE OF THE GLAZING. 5. HAZARDOUS OR WET LOCATIONS LESS THAN 60" AFF GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR WHERE THE NEAREST EXPOSED EDGE OF THE GLAZING IS WITHIN 24 INCHES, EITHER VERTICAL EDGE OF THE DOOR IN A CLOSED POSITION AND WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 60” ABOVE THE WALKING SURFACE. SHEET NUMBER JOB NO. DRAWN DATE CHECKED ARCHITECT STAMP THIS BAR IS 1 INCH ON ORIGINAL DRAWING IF NOT 1 INCH ON THIS SHEET, ADJUST SCALES ACCORDINGLY VERIFY SCALES 0 1" JESSICA © 2020 COPYRIGHT McCARTER-MOORHOUSE & 12.15 DESIGN, LLC. THESE PLANS MAY NOT BE USED BY ANY OTHER ENTITY THAN McCARTER-MOORHOUSE & 12.15 DESIGN, LLC. WITHOUT PRIOR WRITTEN CONSENT. 2/4/2021 8:37:38 AM C:\Files\Dropbox\_ Work _\12.15 Design\2021\Chandler Office Building\Chandler Office Building_working set.rvtA1.0CHANDLER OFFICE BUILDING650 W. FRANKLIN ROAD, MERIDIAN IDAHO001 ENERGY REPORT & SCHEDULES02.04.2021Jessica Petty - Architect 04.17.2020 DOOR SCHEDULE1 NUMBER HEIGHT WIDTH LOCK TYPE HARDWARE NOTES HANDLE FIRE RATING TYPE NOTES 100 8' - 0" 3' - 0" ENTRY CLOSER, WEATHER STRIPPING PANIC BAR 60 MIN C 101 7' - 0" 3' - 0" ENTRY CLOSER PANIC BAR B 106 7' - 0" 3' - 0" OFFICE LEVER B 107 7' - 0" 3' - 0" OFFICE LEVER B 108 7' - 0" 3' - 0" OFFICE LEVER B 109 7' - 0" 3' - 0" OFFICE LEVER B 110 8' - 0" 3' - 0" ENTRY CLOSER, WEATHER STRIPPING PANIC BAR 60 MIN A 122 7' - 0" 3' - 0" 124 8' - 0" 3' - 0" ENTRY CLOSER, WEATHER STRIPPING PANIC BAR 60 MIN A 126 8' - 0" 6' - 0" 129 7' - 0" 3' - 0" 130 7' - 0" 3' - 0" 131 7' - 0" 3' - 0" 132 7' - 0" 3' - 0" 133 7' - 0" 3' - 0" 136 7' - 0" 3' - 0" OFFICE LEVER B 137 7' - 0" 3' - 0" ENTRY CLOSER PANIC BAR B 138 7' - 0" 3' - 0" OFFICE LEVER B 139 7' - 0" 3' - 0" OFFICE LEVER B 142 8' - 0" 6' - 0" 144 7' - 0" 3' - 0" 145 7' - 0" 3' - 0" 147 7' - 0" 3' - 0" 148 7' - 0" 3' - 0" 149 7' - 0" 3' - 0" 150 7' - 0" 3' - 0" OFFICE LEVER B 151 7' - 0" 3' - 0" OFFICE LEVER B 152 7' - 0" 3' - 0" 153 7' - 0" 3' - 0"