Loading...
A0-0 - COVERAND ANGLE AT CENTERLINE DEGREE DIAMETER PLATE PLUS OR MINUS POUND, NUMBER ANCHOR BOLT AIR CONDITIONING ACOUSTICAL ACOUSTICAL CEILING TILE ADDITION ADJACENT ABOVE FINISHED FLOORS AIR HANDLING UNITS ALTERNATE ALUMINUM ANCHOR ANGLE ANODIZED APPROXIMATE ARCHITECT ASPHALT ASSEMBLY ASSOCIATED BOTTOM BALLED AND BURLAPPED BOTTOM OF BOARD BITUMINOUS BUILDING LINE BUILDING BLOCK(ING) BEAM/BENCH MARK BASE OF CURB BOTTOM BEARING BRICK BASEMENT BUILT-UP ROOFING CABINET CALIPER CATCH BASIN CEILING DIFFUSER CEMENT CUBIC FEET -MINUTE CORNER GUARD CAST IRON CONTROL JOINT CEILING CAULK CLEAR CONCRETE MASONRY UNIT CLEAN OUT COLUMN CONCRETE CONNECTION CONSTRUCTION CONTINUOUS CONTRACT(OR) CARPET CEILING REGISTER COUNTERSINK CERAMIC TILE CENTER CONDENSING UNIT CABINET UNIT HEATER COLD WATER & < @ ° Ø ± # A.B. A/C ACOUS. A.C.T. ADDN. ADJ. A.F.F. A.H.U. ALT. ALUM. ANCH. ANG. ANOD. APPROX. ARCH. ASPH. ASSBY. ASSOC. BOT. B&B B.O. BD. BIT. B.L. BLDG. BLK'G. BM. B.O.C. BOTT. BRG. BRK. BSMT. B.U.R. CAB. CAL. C.B. C.D. CEM. C.F.M. C.G. C.I. C.J. CLG. CLK. CLR. C.M.U. C.O. COL. CONC. CONN CONST. CONT. CONTR. CPT. C.R. C.SK. C.T. CTR. C.U. C.U.H. C.W. DOUBLE DEPARTMENT DETAIL DRINKING FOUNTAIN DIAMETER DIMENSION DISPENSER DEAD LOAD DRAINAGE MANHOLE DOWN DISTRIBUTION PANEL DOOR DOWNSPOUT DRAWING EAST EACH EXPANSION BOLT EPOXY FLOORING EXTERIOR INSULATION FINISH SYSTEM EXPANSION JOINT ELEVATOR ELEVATION ELECTRICAL EMERGENCY ENCLOSURE ENGINEER ELECTRICAL PANEL ETHYLENE PROPYLENE DIENE MONOMER EQUAL EQUIPMENT EACH WAY ELECTRIC WATER COOLER ELECTRIC WATER HEATER EXHAUST EXISTING EXPANSION EXTERIOR FIRE ALARM F.A. CONTROL PANEL FLOOR DRAIN FOUNDATION FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FINISHED FLOOR FINISHED GRADE FIRE HYDRANT FIRE HOSE CABINET FINISH(ED) FIXTURE FLOW LINE FLASHING FLOOR(ING) FLUORESCENT FACE OF FACE OF CONCRETE FACE OF FINISH FACE OF MASONRY FACE OF STUD FIREPROOF FIRE PROOF FIBER REINFORCED PANEL FLOOR SINK FOOT, FEET FOOTING FURNISH(ED) FURRING FABRIC WALL COVERING DBL. DEPT. DET. D.F. DIA. DIM. DISP. D.L. D.MH. DN. D.P. DR. D.S. DWG. E. EA. E.B. E.F. E.I.F.S. E.J. EL. ELEV. ELEC. EMERG. ENCL. ENGR. E.P. E.P.D.M. EQ. EQUIP. E.W. E.W.C. E.W.H. EXH. (E) EXP. EXT. F.A. F.A.C.P. F.D. FDN. F.E. F.E.C. F.F. F.G. F.H. F.H.C. FIN. FIXT. F.L. FLASH. FLR.(G) FLUOR. F.O. F.O.C. F.O.F. F.O.M. F.O.S. FP. F.PR. F.R.P. F.S. FT. FTG. FURN. FRR. F.W.C. GAUGE, GAGE GALVANIZED GRAB BAR GENERAL CONTRACTOR GROUND FAULT INTERRUPTER GALVANIZED IRON GYPSUM HOSE BIBB HOLLOW CORE HARDWOOD HARDWARE HEIGHT HIGH INTENSITY DISCHARGE HOLLOW METAL HOLD OPEN HORIZONTAL HIGH POINT HOUR HEIGHT HEAT, VENT, A/C HOT WATER INSIDE DIAMETER INCH INCANDESCENT INCLUDE (D) (ING) INSULAT(ED)(ION) INTERIOR INVERT JANITOR JUNCTION BOX JOINT KIP (1,000 POUNDS) KIP FEET KEYBOARD KITCHEN KNOCK OUT LAMINATED LAVATORY POUND(S) LEAD COATED COPPER LINEAR FEET LEFT HAND LIVE LOAD LONG LEG HORIZONTAL LONG LEG VERTICAL LOW POINT LIGHTING PANEL LIGHT (ING) LIGHTWEIGHT MAGNETIC MASONRY MATERIAL MAXIMUM MACHINE BOLT MAIN DISTRIBUTION PANEL MECHANICAL MEDIUM MEMBRANE METAL MANUFACTURER MANHOLE MINIMUM MISCELLANEOUS MASONRY OPENING MOISTURE RESISTANT MOUNTED GA. GALV. G.B. G.C. G.F.I. G.I. GYP. H.B. H.C. HDWD. HDWR. HGT. H.I.D. H.M. H.O. HORIZ. H.P. HR. HT. HVAC H.W. I.D. IN. INCAND. INCL. INSUL. INT. INV. JAN. J.B. JT. K K-FT. KB. KIT. K.O. LAM. LAV. LB.(S) L.C.C. L.F. L.H. L.L. L.L.H. L.L.V. L.P. LT.P. LT.(G) LTWT. MAG. MAS. MAT. MAX. M.B. M.D.P. MECH. MED. MEMB. MTL. MFR. M.H. MIN. MISC. M.O. M.R. MTD. PRNORTH NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE OVER ON CENTER(S) OUTSIDE DIAMETER OFFICE OWNER FURNISHED CONTRACTOR INSTALLED OWNER FURNISHED OWNER INSTALLED OPEN ITEM OPENING OPPOSITE ORIENTED STRAND BOARD OUT TO OUT OUNCE PROPERTY LINE PROJECT ARCHITECT PARTICLE BOARD POUNDS -CUBIC FOOT PERFORATED PLATE PLASTIC LAMINATE PLASTER PLUMBING POUNDS -LINEAR FOOT PLYWOOD PANEL POLISH(ED) POWER PANEL PAIR PROJECT PARTITION POUNDS -SQUARE FOOT POUNDS -SQUARE INCH PAINT/ POINT PAINTED PLUMBING VENT POLYVINYL CHLORIDE PAVEMENT QUARRY TILE QUANTITY RADIUS RUBBER BASE REFLECTED CEILING PLAN ROOF DRAIN REFERENCE RECESSED RECEPTACLE REFRIGERATOR REINFORCE (D) (ING) REQUIRED RESILIENT REVISIONS, REVISED ROOFING RIGHT HAND ROOM ROUGH OPENING RIGHT OF WAY RESTROOM ROOF TOP UNIT RAIN WATER LEADER ROOF VENT N N.I.C. NO. NOM. N.T.S o' O.C. O.D. OFF. O.F.C.I. O.F.O.I. O.I. OPG. OPP. O.S.B. O.T.O. OZ. P/L P.A. P.BD. P.C.F. PERF. PL P.LAM. PLAS. PLBG. P.L.F. PLYWD. PNL. POL. P.P. PR. PROJ. PRTN. P.S.F. P.S.I. PT. PTD. P.V. PVC PVMT. Q.T. QTY. R R.B. R.C.P. R.D. RE. REC. RECPT. REF. REINF. REQ. RESIL. REV. RFG. R.H. RM. R.O. R.O.W. R.R. R.T.U. R.W.L. R.V. SOUTH SANITARY SUSPENDED ACOUSTICAL CEILING SOLID CORE SCHEDULE STORM DRAIN SEALANT SECTION SERVICE SQUARE FEET SAFETY GLASS SHEET SHEATHING SHOWER SIMILAR SHEET METAL SANITARY MANHOLE SHEET METAL SCREWS SPRAY ON VINYL SPECIFICATIONS SQUARE SOLID SURFACE STAINLESS STEEL STANDARD STEEL STORAGE STRUCTURAL STORM SEWER SUSPENDED SYMMETRICAL SYSTEM TREAD TOWEL BAR TOP OF TONGUE AND GROOVE TELEPHONE TEMPERATURE, TEMPERED THICK THRESHOLD TOILET PARTITION TOILET PAPER DISPENSER TYPICAL TELEVISION UNIT HEATER UNLESS NOTED OTHERWISE UNFINISHED ULTRA VIOLET VINYL COMPOSITION TILE VENTILATION VERTICAL VESTIBULE VERIFY IN FIELD VINYL VINYL WALL COVERING WEST WITH WATER CLOSET WOOD WATER HEATER WINDOW WATERPROOF WATER RESISTANT WAINSCOT WEIGHT WATER VALVE WELDED WIRE FABRIC YARD S SAN. S.A.C. S.C. SCHED. S.D. SEAL. SECT. SERV. S.F. S.G. SHT. SHTHG. SHWR. SIM. S.M. S.MH. SMS S.O.V. SPEC. SQ. SS S.STL. STD. STL. STOR. STRUCT. S.S. SUSP. SYM. SYS. T. T.B. T.O. T&G TEL. TEMP. THK. THRES. T.P. T.P.D. TYP. TV U.H. U.N.O. UNFIN. UV VCT VENT. VERT. VEST. V.I.F. VIN. V.W.C. W w/ W.C. WD. W.H. WIN. WP. W.R. WSCT. WT. W.V. W.W.F. YD ABBREVIATIONS CHANDLER OFFICE BUILDING PARCEL# S1212438485 650 W. FRANKLIN ROAD, MERIDIAN IDAHO PL CL SITE INFO GENERAL NOTES 1. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER REMOVAL TECHNIQUES AND DISPOSAL OF DEBRIS. ANY CLEARING WORK SHALL BE COORDINATED WITH ALL AFFECTED UTILITY COMPANIES AND SHALL CONFORM WITH CITY, COUNTY, AND STATE CODES FOR DISPOSAL OF DEBRIS. 2. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING, IDENTIFYING AND PROTECTING ANY UTILITIES THAT ARE TO REMAIN FROM DAMAGE. ANY UTILITY LINES THAT ARE IDENTIFIED BY THE LOCAL UTILITY COMPANIES AS ACCEPTABLE FOR REMOVAL SHALL BE DONE IN ACCORDANCE WITH THE STANDARDS ESTABLISHED BY THE UTILITY COMPANY AFFECTED. 3. ALL NEW PLUMBING, GAS, MECHANICAL AND ELECTRICAL SERVICES INTO THE NEW CONSTRUCTION AREAS SHALL BE DONE IN ACCORDANCE WITH ALL STATE AND LOCAL CODES AND ORDNANCES. 4. ALL MATERIAL AND WORKMANSHIP SHALL CONFORM TO THE PLANS AND CURRENT INTERNATIONAL RESIDENTIAL CODE. 5. VERIFY ALL EXISTING CONDITIONS AND CHECK ALL DIMENSIONS AND ELEVATION PRIOR TO STARTING WORK. NOTIFY DESIGNER OF ANY DISCREPANCIES FOUND PRIOR TO PROCEEDING WITH WORK. 6. DIMENSIONS SHOWN DO NOT INCLUDE THE THICKNESS OF ANY APPLIED FINISH MATERIALS. DIMENSIONS ARE EITHER TO FACE OF STUD, FACE OF MASONRY, OR CENTERLINE OF OPENINGS OR STRUCTURE. SHEET INDEX 2018 INTERNATIONAL BUILDING CODE 2018 INTERNATIONAL RESIDENTIAL CODE 2018 INTERNATIONAL EXISTING BUILDING CODE 2018 INTERNATIONAL ENERGY CONSERVATION CODE 2018 INTERNATIONAL MECHANICAL CODE 2018 INTERNATIONAL FUEL GAS CODE BUILDING CODES OCCUPANCY TYPE B SEISMIC ZONE C ZONING L-O BUILDING CONSTRUCTION V-B AREA OF NEW CONSTRUCTION 4,167 MAIN LEVEL OCCUPANT LOAD:41 (SEE BELOW) FIRE SUPPRESSION SYSTEM: NO TENANT A: AREA: 2,085 SQFT OCCUPANT LOAD: 1:100 = 21 WATER CLOSETS: 1 PER 25 - FIRST 50 / 1 PER 50 REQUIRED:1 MEN / 1 WOMEN LAVATORIES: 1 PER 40 - FIRST 80 / 1 PER 80 REQUIRED:1 MEN / 1 WOMEN DRINKING FOUNTAIN: 1 PER 100, UNLESS LESS THAN 15 OCCUPANTS (IBC 2902.6) REQUIRED:NO SERVICE SINK: 1 PER 100, UNLESS LESS THAN 15 OCCUPANTS (IBC 2902.1e) REQUIRED:1- SHARED SITE TENANT B: AREA:1,989 SQFT OCCUPANT LOAD: 1:100 = 20 WATER CLOSETS: 1 PER 25 - FIRST 50 / 1 PER 50 REQUIRED:1 MEN / 1 WOMEN LAVATORIES: 1 PER 40 - FIRST 80 / 1 PER 80 REQUIRED:1 MEN / 1 WOMEN DRINKING FOUNTAIN: 1 PER 100, UNLESS LESS THAN 15 OCCUPANTS (IBC 2902.6) REQUIRED:NO SERVICE SINK: 1 PER 100, UNLESS LESS THAN 15 OCCUPANTS (IBC 2902.1e) REQUIRED:1 - SHARED EXIT EXIT EXIT TENANT A TENANT B EXIT SHEET NUMBER JOB NO. DRAWN DATE CHECKED ARCHITECT STAMP THIS BAR IS 1 INCH ON ORIGINAL DRAWING IF NOT 1 INCH ON THIS SHEET, ADJUST SCALES ACCORDINGLY VERIFY SCALES 0 1" JESSICA © 2020 COPYRIGHT McCARTER-MOORHOUSE & 12.15 DESIGN, LLC. THESE PLANS MAY NOT BE USED BY ANY OTHER ENTITY THAN McCARTER-MOORHOUSE & 12.15 DESIGN, LLC. WITHOUT PRIOR WRITTEN CONSENT. 2/4/2021 8:37:33 AM C:\Files\Dropbox\_ Work _\12.15 Design\2021\Chandler Office Building\Chandler Office Building_working set.rvtA0.0CHANDLER OFFICE BUILDING650 W. FRANKLIN ROAD, MERIDIAN IDAHO001 COVER02.04.202111.09.2018 SHEET NAME A0.0 COVER A0.1 LANDSCAPE PLAN A0.2 SITE PLAN A0.3 ADA DETAILS A0.4 EGRESS PLAN & DETAILS A1.0 ENERGY REPORT & SCHEDULES A1.1 FLOOR PLAN A2.1 REFLECTED CEILING PLAN A3.1 ELEVATIONS A3.2 ELEVATIONS A3.3 COLOR ELEVATIONS & RENDERINGS A4.1 ROOF PLAN A5.1 SECTIONS