Jakers Meridian - CUP-DR DrawingsA.ALL DESIGN CRITERIA NOT SHOWN ON THESE PLANS ARE TO CONFORM TO STANDARD FRAMING PER THE INTERNATIONAL BUILDING CODE. B.ALL INFORMATION CONTAINED WITHIN THESE DRAWINGS AND ALL ENGINEERING CALCULATIONS ARE INTENDED TO MEET OR EXCEED THE INTERNATIONAL BUILDING CODE. C.ALL WORK SHALL BE DONE IN STRICT COMPLIANCE WITH THE PREVAILING BUILDING AND LIFE SAFETY CODES. D.THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT, USING HIS/HER BEST SKILL AND ATTENTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. E.LABOR SHALL BE PERFORMED BY MECHANICS SKILLED AND EXPERIENCED IN THEIR RESPECTIVE TRADES. WORK THROUGHOUT SHALL BE OF THE HIGHEST STANDARDS. F.THE CONTRACTOR SHALL INSPECT THE PREMISES IMMEDIATELY TO CHECK EXISTING CONDITIONS. SHOULD THE CONTRACTOR FIND CONDITIONS WHICH HE/SHE BELIEVES WOULD IMPEDE HIS/HER WORK, THEN SUCH CONDITIONS MUST BE REPORTED IMMEDIATELY TO THE ARCHITECT. FAILURE TO DO SO WILL CONSTITUTE NOTICE THAT THE CONTRACTOR IS FULLY SATISFIED WITH THE EXISTING CONDITIONS. G.THE CONTRACTOR SHALL FAMILIARIZE HIMSELF/HERSELF WITH THE PROJECT THROUGH INSPECTION OF THE JOB SITE, DRAWINGS AND SPECIFICATIONS, SO AS TO THOROUGHLY UNDERSTAND THE WORK. ANY AND ALL DISCREPANCIES AND OMISSIONS SHALL BE REPORTED AND CLARIFICATION SHALL BE OBTAINED FROM THE OWNER AND ARCHITECT PRIOR TO WORK BEING DONE. THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS IN THE FIELD. IF DIMENSIONAL ERROR OCCURS OR CONDITIONS NOT COVERED IN THE DRAWINGS ARE ENCOUNTERED, CONTRACTOR SHALL NOTIFY THE ARCHITECT BEFORE COMMENCING THAT PORTION OF THE WORK. H.THE CONTRACTOR SHALL GUARANTEE IN WRITING ALL LABOR, MATERIALS, AND WORKMANSHIP INSTALLED BY HIM/HER FOR A PERIOD OF NOT LESS THAN ONE (1) YEAR AFTER DATE OF ACCEPTANCE OF THE WORK BY THE OWNER EXCEPT AS MODIFIED HEREIN OR ON OTHER DRAWINGS. SHOULD DEFECTS OCCUR, ALL WORK SHALL BE REPLACED OR PROPERLY REPAIRED AT NO ADDITIONAL COST TO THE OWNER. I.CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THE SITE IN A CLEAN AND SAFE CONDITION, INCLUDING PROPER REMOVAL OF WASTE MATERIAL. WASTE MATERIAL SHALL NOT BE STORED WITHIN OR NEAR THE BUILDING. DUMPSTERS PROVIDED FOR THE DISPOSAL OF WASTE MATERIAL SHALL BE REMOVED AWAY FROM THE BUILDING BUT MAY BE STORED ON SITE DAILY. J.THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL COMBUSTIBLE FLUIDS INCLUDING PAINT, PRIMERS, SEALERS, SOLVENTS AND ADHESIVES COMPLY, AND ARE BEING USED IN ACCORDANCE WITH THE PRODUCT MANUFACTURER'S WRITTEN INSTRUCTIONS. CONTRACTOR SHALL PROVIDE STORAGE FOR SUCH MATERIALS AWAY FROM THE BUILDING. USE OF THE BUILDING FOR SUCH STORAGE IS PROHIBITED. K.ALL ITEMS EXPRESSED, DRAWN, NOTED, OR SPECIFIED WITHIN THESE DOCUMENTS SHALL BE PROVIDED AND INSTALLED BY THE CONTRACTOR UNLESS NOTED OTHERWISE. ANY ITEMS NOT INCLUDED AND REQUIRED ARE THE RESPONSIBILITY OF THE CONTRACTOR. IT IS ASSUMED THAT THE BIDDER HAS BID ALL PRODUCTS AND SYSTEMS DESCRIBED IN THE DOCUMENTS AS COMPLETE AND READY FOR USE, REGARDLESS OF THE COMPLETENESS OF THE PRODUCT OR SYSTEM DESCRIPTION. ANY DISCREPANCIES IN THE DOCUMENTS ARE TO BE CLASSIFIED VIA R.F.I. DURING THE BIDDING PERIOD. OTHERWISE THEY ARE ASSUMED TO HAVE BEEN BID AS THE MORE EXPENSIVE OPTION. L.ALL MECHANICAL WORK SHALL BE IN STRICT COMPLIANCE WITH PREVAILING CODES, WHICHEVER IS MOST STRINGENT. M.ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH PREVAILING CODES, WHICHEVER IS MOST STRINGENT. N.CONTRACTOR TO COORDINATE WITH EQUIPMENT SHOWN AS PROVIDED BY OTHERS AND PROVIDE ALL REQUIRED POWER, WATER, DRAIN, VENT OR GAS CONNECTIONS. O.SMOKE DETECTORS SHALL BE LOCATED AS REQUIRED. P.CONTRACTOR IS RESPONSIBLE FOR FINAL CLEAN-UP OF ALL EXPOSED SURFACES AT SUBSTANTIAL COMPLETION. Q.SHOP DRAWINGS AND SUBMITTALS SHALL BE SUPPLIED BY THE CONTRACTOR. SHOP DRAWINGS AND SUBMITTALS SHALL INCLUDE PROJECT NAME, LOCATION FOR USE, PRODUCT INFORMATION, DIMENSIONS, FINISHES AND OPTIONS, WARRANTY INFORMATION AS APPLICABLE. SUBMITTALS MAY BE REQUIRED FOR THE FOLLOWING ITEMS AT CONTRACTOR'S REQUEST: DOORS AND FRAMES, WINDOWS, MILLWORK, MECHANICAL AND ELECTRICAL SYSTEMS, CONCRETE DESIGN, EXTERIOR FINISHES, HARDWARE, PAINT/ STAIN, GLAZING AND FRAMES, WOOD AND FINISHES, ROOFING, STRUCTURAL FRAMING. R.ALL INSULATION MATERIAL INCLUDING FACINGS ARE REQUIRED TO HAVE A FLAME SPREAD OF 25 OR BETTER AND A MAXIMUM SMOKE DENSITY OF 450 PER THE IBC. S.GYPSUM BOARD MATERIALS SHALL CONFORM TO THE APPROPRIATE STANDARDS LISTED IN THE IBC. GYPSUM BOARD MATERIALS SHALL BE ASSEMBLED AND INSTALLED IN COMPLIANCE WITH THE APPROPRIATE STANDARDS LISTED IN THE IBC. T.ALL WALLS EXTENDING TO THE BOTTOM OF ROOF DECK AND/OR STRUCTURE NEED TO BE SEALED USING INDUSTRY STANDARD SEALANT OR FOAM TO PREVENT SOUND INFILTRATION. U.GENERAL CONTRACTOR SHALL CALL DIGLINE AT 811 TO LOCATE ALL EXISTING UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION. V.CONTRACTOR TO VERIFY AND COORDINATE ROOF PENETRATIONS, CURBS, EQUIPMENT LOCATIONS WITH MECHANICAL AND PLUMBING. SEAL ALL THROUGH-ROOF PENETRATIONS AIR TIGHT. W.THE CONSTRUCTION DOCUMENT WITH ITS REFERENCED ATTACHMENTS IS PART OF THE PROCUREMENT AND CONTRACTING REQUIREMENTS FOR PROJECT. X.THE PLANS AND SPECIFICATIONS AS A WHOLE MAKE UP THE CONTRACT DOCUMENTS. THE CONTRACTOR AND THEIR SUBCONTRACTORS ARE RESPONSIBLE FOR USING THE DOCUMENTS AS A WHOLE FOR COORDINATION BETWEEN TRADES AND VARIOUS REQUIREMENTS. Y.DO NOT SCALE PLANS. USE THE PROVIDED DIMENSIONS OR SEEK CLARIFICATION FROM THE ARCHITECT WHERE DIMENSIONAL INFORMATION IS MISSING. Z.DIMENSIONS ARE TO FACE OF STUD UNLESS NOTED OTHERWISE. BUILDING DATA/CODE ANALYSIS GENERAL NOTES DRAFTING SYMBOLSDRAWING INDEX PROJECT TEAM OWNER JAKERS 3268 E PINE AVE MERIDIAN, ID 83642 (406) 248-9913 CONTACT: JAKE JONES PAVER SUB WEAVER MASONRY BENJERMINAARON@GMAIL.COM CONTACT: BEN WEAVER NORTH 1 A-1 1 A-1 REFERENCE (SEE ELEVATION DETAIL REFERENCE (SEE DETAIL 1 ON A-1) INTERIOR ELEVATION 1 ON A-1) (SEE SECTION 1 ON A-1) SECTION REFERENCE KEYED NOTE DOOR NUMBER WINDOW TYPE ROOM NAME AND NUMBER A 1 PLYWOOD RIGID INSULATION GYPSUM BOARD BATT INSULATION FINISH LUMBER (STRUCTURAL STEEL) SAND METAL WOOD MASONRY UNIT CONCRETE GRAVEL EARTH 100A GENERAL G0.1 COVER SHEET ARCHITECTURAL SD1.0 SITE PLAN A1.1 FLOOR PLAN/DETAILS LEGAL ADDRESS: 3268 E PINE AVE MERIDIAN, ID 83642 PARCEL NUMBER: R7361210075 ZONING CODE: C-G SUBDIVISION: REAGAN SUB LOT/BLOCK: L:06,07,08/B:01 BUILDING OCCUPANCY: A-2 BUILDING SIZE TOTAL: 5,412 +/- S.F. TENANT SIZE TOTAL: 50 S.F. NUMBER OF STORIES: 1 CONSTRUCTION TYPE: V-B FIRE SPRINKLERS: NO FIRE ALARM: NO OCCUPANT LOAD: SHED AREA (X2) : 25 SF / 150 = 1 OCC. TOTAL OCCUPANT LOAD: 2 APPLICABLE CODE: 2018 INTERNATIONAL BUILDING CODE 2018 IDAHO ENERGY CONSERVATION CODE 2018 INTERNATIONAL MECHANICAL CODE 2017 IDAHO STATE PLUMBING CODE 2017 NATIONAL ELECTRIC CODE 2018 INTERNATIONAL FIRE CODE 2009 ICC/ANSI A117.1 ACCESSIBILITY CODE PROVI D E D OCCU P A N T S PER G R O U P OCCU P A N C Y GROU P REQUI R E D:(.3"xO C C U P A N T) A-2 TOTAL = 2 0.6"72" EXITING ANALYSIS: ALLOWABLE OCCUP. AND REQUIRED EXIT WIDTH ARCHITECT BRS ARCHITECTS 1010 S. ALLANTE PL. #100 BOISE, ID 83709 (208) 336-8370 CONTACT: MARK ANDERSON PROJECT LOCATION VICINITY PLAN JAKERS DRIVE-THROUGH ADDITION MERIDIAN, ID 100 OFFICE A7.1 1 1010 S. ALLANTE PL.SUITE 100BOISE, IDAHO 83709(208) 336-8370FAX (208) 336-8380PROPOSED DESIGN FOR:CHECKED JOB NO. DATE DRAWN 20086 2/5/2021 MLAREVISIONS NO. DATE COPYRIGHT 2021 BRS ARCHITECTS * ALL RIGHTS RESERVED. REPRODUCTION OR TRANSLATION OF ANY PART OF THIS WORK WITHOUT WRITTEN PERMISSION OF BRS ARCHITECTS IS UNLAWFUL AND SUBJECT TO CRIMINAL PROSECUTION.MLA 3268 E PINE AVEMERIDIAN, ID 83642JAKERS DRIVE-THROUGHADDITIONG0.1 COVER SHEET SHED SUB IDAHO WOOD SHEDS (208) 888-1090 INFO@IDAHOWOODSHEDS.COM CONTACT: JOSEPH BRADSHAW SIGN SUB GOLDEN WEST SIGNS (208) 850-5071 BMOORE@GOLDENWESTSIGNS.COM CONTACT: ROBERT MOORE ELECTRIC SUB EDWARDS ELECTRIC (208) 407-7134 EDWARDSELECTRIC@GMAIL.COM CONTACT: JOHN EDWARDS 90 STALLS (NEW) 59,663 S.F. CARRABBASACCESS ROADONEWAYONEWAYDRIVETHRUDRIVETHRUEXIT93 STALLS (ORIGINAL) TRASH SCALE: 1"=15'-0" SITE PLAN 1010 S. ALLANTE PL.SUITE 100BOISE, IDAHO 83709(208) 336-8370FAX (208) 336-8380PROPOSED DESIGN FOR:CHECKED JOB NO. DATE DRAWN 20086 2/5/2021 MLAREVISIONS NO. DATE COPYRIGHT 2021 BRS ARCHITECTS * ALL RIGHTS RESERVED. REPRODUCTION OR TRANSLATION OF ANY PART OF THIS WORK WITHOUT WRITTEN PERMISSION OF BRS ARCHITECTS IS UNLAWFUL AND SUBJECT TO CRIMINAL PROSECUTION.MLA 3268 E PINE AVEMERIDIAN, ID 83642JAKERS DRIVE-THROUGHADDITIONSD1.0 SITE PLAN NORTH KEYED NOTES 1 1.EXISTING BUILDING TO BE UNDISTURBED. 2.NEW 16X16 CONCRETE PAVER SIDEWALK (79 COUNT), SLOPE TOWARD PARKING LOT. 3.NEW TEMPORARY DRIVE-THROUGH SHED BY OTHERS. 4.EXISTING 4' BERM WITH 6' FENCE AT PEAK. 5.EXISTING PARKING STRIPING TO BE REMOVED AND REPAINTED AT 45 DEGREES TO MEET ZONING CODE PER TABLE 11-3C-5. 6.NEW PARKING LOT STRIPING TO DESIGNATE NEW TRAFFIC PATTERN APPROPRIATELY. 7.EXISTING A/C CONDENSER TO REMAIN, TBD BY CONTRACTOR. 8.NEW SHELVING TO BE INSTALLED FOR TEMPORARY FOOD PICKUP AREA. 9.NEW LIGHT POLE TO BE INSTALLED. BASIS OF DESIGN, POLE: "LITHONIA LIGHTING" 4" SQUARE LIGHT POLE 20' TALL, SSS204CDM19DDBL/AB. LIGHT FIXTURE: "RAB LIGHTING" POLE LIGHT, ALED150 TYPE III, OR APPROVED EQUAL FOR POLE AND LIGHT FIXTURE TO MATCH EXISTING. 10.NEW ILLUMINATED DIRECTIONAL SIGN TO BE PERMITTED BY SIGN COMPANY. PROVIDE UNDERGROUND CONDUIT AND J-BOX TO SIGN LOCATION. 11.NEW FOOD PICKUP SIGN. SIGN TO BE PERMITTED BY SIGN COMPANY. 12.NEW 3'X7' SOLID CORE WOOD DOOR LEAF WITH (3) BALL BEARING HINGES, LEVER HARDWARE WITH PASSAGE LATCHSET. MATCH EXISTING DOOR/FRAME COLOR AND HARDWARE FINISHES ACCORDINGLY. 1 2 10 5'-4"13'-6"12'-0"2 4 ' - 3 1 / 2 "9'-0"86'-11" 4 56 7 12'-10"4" 8 6 21'-6"9 310 10 3 111'-6"12 FE OS FE OS SCALE: 1/2"=1'-0" FLOOR PLAN 1010 S. ALLANTE PL.SUITE 100BOISE, IDAHO 83709(208) 336-8370FAX (208) 336-8380PROPOSED DESIGN FOR:CHECKED JOB NO. DATE DRAWN 20086 2/5/2021 MLAREVISIONS NO. DATE COPYRIGHT 2021 BRS ARCHITECTS * ALL RIGHTS RESERVED. REPRODUCTION OR TRANSLATION OF ANY PART OF THIS WORK WITHOUT WRITTEN PERMISSION OF BRS ARCHITECTS IS UNLAWFUL AND SUBJECT TO CRIMINAL PROSECUTION.MLA 3268 E PINE AVEMERIDIAN, ID 83642JAKERS DRIVE-THROUGHADDITIONA1.1 PLANS NORTH LEGEND NEW DUPLEX ELECTRICAL OUTLET OR NEW RECEPTACLE TO BE INSTALLED FE NEW 2-A:10-B:C RATED FIRE EXTINGUISHER WITH BRACKET MOUNT OR IN FIRE RATED SEMI-RECESSED CABINET (RATING TO MATCH ADJACENT WALL RATING AS APPROPRIATE). INSTALL AT 46" A.F.F. TO EXTINGUISHER HANDLE. OCCUPANCY SENSOR IN AREA NOTED TO COMPLY WITH LIGHT REDUCTION CONTROL PER IECC SECTION C405.2.1.1. OS KEYED NOTES 1 1.NEW PREFAB SHED BY OTHRES. EXTERIOR WALL CONSTRUCTION: 2X6 WOOD STUDS @ 16" O.C. TO UNDER SIDE OF ROOF RAFTERS W/ 5/8" TYPE "X" GYPSUM BOARD EACH SIDE. INFILL CAVITY WITH R-19 BATT INSULATION AND VISQUEEN VAPOR BARRIER ON INSIDE FACE OF STUDS. TAPE SMOOTH, AND PROVIDE LEVEL 4 FINISH. INTERIOR FINISHES AND COLORS TBD BY OWNER. 2.NEW 3'X3' VINYL SINGLE HUNG WINDOW TO BE INSTALLED AT 3' A.F.F. CENTERED ON SOUTH WALL, AND NEW 3'X3' VINYL FIXED WINDOW TO BE INSTALLED AT 3' A.F.F. CENTERED ON WEST WALL. 3.NEW 3'X7' INSULATED DOOR WITH (3) BALL BEARING HINGES, LEVER HARDWARE WITH OFFICE/ENTRY LOCKSET, RAIN DRIP, DOOR SWEEP, AND PERIMETER WEATHERSTRIP. CENTER IN WALL. 4.5/8" GYP BOARD CEILING AT 7'-6" A.F.F. OVER 2X4 WOOD FRAMING @ 16" O.C. 5.ASPHALT ROOFING, COLOR TO CLOSELY MATCH JAKER'S CEDAR ROOF. INSTALL SHINGLES OVER ROOFING PAPER OVER APPROVED ROOF SHEATHING OVER 2X6 ROOF RAFTERS @ 16" O.C. INSTALL PER MFR RECOMMENDATIONS. 6.6" HARDIEBOARD FASCIA ATTACHED TO ROOF RAFTERS. PAINT TO MATCH JAKER'S RED FASCIA. 7.HARDIEBOARD VENTED SOFFIT ATTACHED TO UNDERSIDE OF ROOF RAFTERS. PAINT TO MATCH JAKER'S GREEN STUCCO. 8.3" HARDIEBOARD STUCCO CORNER TRIM. PAINT TO MATCH JAKERS GREEN STUCCO. 9.16" HARDIEBOARD STUCCO SIDING OVER 2 LAYERS WATERPROOF MEMBRANE OVER APPROVED WALL SHEATHING. INSTALL PER MFR RECOMMENDATIONS, PAINT TO MATCH JAKER'S GREEN STUCCO. 10.2" WIDE RECESSED GOLD-COLORED FLASHING ATTACHED TO SUBSTRATE TO MATCH JAKER'S GOLD TRIM. INSTALL CLEAR ALL WEATHER SEALANT AT PERIMETER.5'-0"5'-0"5'-0"5'-0" WEST SHED EAST SHED 31 3 1 2 SCALE: 1/2"=1'-0" CEILING PLAN NORTH WEST SHED EAST SHED 4 NEW 6" DIA. RECESSED CAN LIGHT TO BE INSTALLED IN CEILING 4 SCALE: 1/2"=1'-0" WEST SHED ELEVATIONS (EAST SHED SIM.) 5 6 8 9 10 7 8'-5"3 12 7"3'-7"5 6 8 9 10 7 SCALE: 1/2"=1'-0" TYPICAL WALL SECTION 5 6 9 10 7 2X6 2X6 2X6 2X6 2X4 1" OSB SUBFLOOR 3 12 3 12 6" 2 22 WEST ELEVATION NORTH ELEVATION SOUTH ELEVATION EAST ELEVATION3'-7" SOUTH ELEVATION 1010 S. ALLANTE PL.SUITE 100BOISE, IDAHO 83709(208) 336-8370FAX (208) 336-8380PROPOSED DESIGN FOR:CHECKED JOB NO. DATE DRAWN 20086 2/5/2021 MLAREVISIONS NO. DATE COPYRIGHT 2021 BRS ARCHITECTS * ALL RIGHTS RESERVED. REPRODUCTION OR TRANSLATION OF ANY PART OF THIS WORK WITHOUT WRITTEN PERMISSION OF BRS ARCHITECTS IS UNLAWFUL AND SUBJECT TO CRIMINAL PROSECUTION.MLA 3268 E PINE AVEMERIDIAN, ID 83642JAKERS DRIVE-THROUGHADDITIONA2.1 SITE PHOTOS EAST ELEVATION VIEW LOOKING WEST EXAMPLE OF GOLD TRIM WALL VIEW LOOKING NORTH WEST ELEVATION VIEW LOOKING EAST NORTH ELEVATION VIEW LOOKING SOUTH