Loading...
CC - Landscape Plans GENERAL LANDSCAPE NOTES GENERAL IRRIGATION NOTES ..••"""'•��. NOTE: CALCULATIONS SHOWN BELOW ARE TO DETERMINE THE REQUIRED NUMBER OF TREES PER CITY OF �••` �EOFID�9,,�••, MERIDIAN UDC AND ARE NOT OPEN SPACE CALCULATIONS. REFER TO THE OPEN SPACE EXHIBIT FOR OFFICIAL 1. VERIFICATION OF TOTAL LANDSCAPE MATERIAL QUANTITIES AS SHOWN ON THIS 1. NO GUARANTEE IS MADE THAT ALL EXISTING UNDERGROUND UTILITIES ARE SHOWN, OR SHOWN ��� c C •••••••••c �� ��,� QUALIFIED OPEN SPACE CALCULATIONS. LANDSCAPE PLAN AND IN THE PLANT SCHEDULE SHALL BE THE RESPONSIBILITY OF CORRECTLY. CONTRACTOR SHALL VERIFY LOCATION OF ALL UTILITIES PRIOR TO INITIATION OF .• �•,�SSAYEN;••• •dp \ THE LANDSCAPE CONTRACTOR. IF QUANTITIES LISTED DO NOT CORRELATE WITH WHAT ANY DEMOLITION OR CONSTRUCTION OPERATIONS. ANY DAMAGE TO EXISTING UTILITIES SHALL * 'y �* 'w OPEN SPACE TREE CALCULATIONS (1TR E E/8000S F) IS SHOWN ON THE PLAN, THE QUANTITIES SHOWN ON THE PLAN SHALL GOVERN. THIS BE CONTRACTOR'S RESPONSIBILITY. INCLUDES, BUT IS NOT LIMITED TO TREE, SHRUB, ROCK, TOPSOIL, MULCH, SEED OR SOD, EDGING, AND DRIP LINE QUANTITIES. 2. THE CONTRACTOR IS RESPONSIBLE TO FURNISH AND INSTALL A COMPLETE IRRIGATION : � ! ; W BLOCK # LOT # LOT QUALIFIED AREA (SF) QUALIFIED REQ PRVD SYSTEM WHICH PROVIDES ADEQUATE WATER COVERAGE TO ALL LAWN AND PLANTING Z i A 165 '7 E. LAKE HAZEL RD. AREA (SF) AREA (AC) 2. IMMEDIATELY AFTER AWARD OF CONTRACT, NOTIFY THE LANDSCAPE ARCHITECT OF AREAS. THE WORK SHALL CONSIST OF PROVIDING AND INSTALLING ALL MATERIALS '•,`n�•••• �F/1/21 •.•• �.` 3 24 3,014 3,014 0.07 0.00 0.00 AVAILABLY OF SPECIFIED PLANT MATERIAL FROM COMMERCIAL NURSERIES. IF A NECESSARY FOR A COMPLETE SYSTEM INCLUDING POINT OF CONNECTION, PIPE, '•,��Lq ••••••••�e¢�•` 3 31 3,120 3,120 0.07 0.00 0.00 ALTERNATE TERNE PLANT I MATERIAL AVAILABLE, THE LANDSSUCH CAPE ARCHITECT WILL PROMALTER THE VALVES, FITTINGS, HEADS, AUTOMATIC CONTROLS, AND ALL ASSOCIATED LABOR. �,��,;D;,,p•••�• 3 37 3,022 3,022 0.07 0.00 0.00 ORIGINAL BID PRICE UNLESS A CREDIT IS DUE TO THE OWNER. 3. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS AND FEES REQUIRED FOR THIS WORK 3 42 1,431 1,431 0.03 0.00 0.00 3. CONTRACTOR SHALL LOCATE AND IDENTIFY EXISTING UNDERGROUND AND OVERHEAD 4. ALL MATERIALS SHALL BE NEW AND WITHOUT FLAWS OR DEFECTS. 7 23 4,548 4,548 0.10 1.00 1.00 UTILITIES WITHIN CONTRACT WORK AREAS PRIOR TO CONSTRUCTION. CONTACT DIG �Pk LINE, INC. ® 1.800.342.1885. PROVIDE ADEQUATE MEANS OF PROTECTION OF 5. INSTALLATION SHALL COMPLY WITH ALL NATIONAL, STATE, AND LOCAL LAWS AND ORDINANCES. 6,004 UTILITIES AND SERVICES DESIGNATED TO REMAIN. REPAIR UTILITIES DAMAGED DURING 6. POINT OF CONNECTION: COMPLY WITH REQUIREMENTS OF UTILITY SUPPLYING WATER 7 30 8,455 EXCLUDES 25' BUFFER 0.14 1.00 1.00 SITE WORK OPERATIONS AT CONTRACTOR'S EXPENSE. FOR PREVENTION OF BACKFLOW AND BACK-SIPHONAGE SEE STREET TREE CALC. 4. PROVIDE REQUIRED SOIL EROSION CONTROL MEASURES THROUGHOUT THE DURATION OF �Q 8 8 3,902 3,902 0.09 0.00 0.00 7. COVERAGE; THE IRRIGATION SYSTEM SHALL BE DESIGNED TO PROVIDE ONE HUNDRED �. THE CONTRACT PERIOD. SHOULD THERE BE EXISTING SOIL EROSION CONDITIONS THAT � REQUIRE MITIGATION, NOTIFY THE RESPONSIBLE PERSON IMMEDIATELY. FAILURE TO PERCENT (100%) COVERAGE WITH HEAD TO HEAD SPACING OR TRIANGULAR SPACING ui 8 15 2,028 2,028 0.05 0.00 0.00 < AS APPROPRIATE. NOTIFY THE RESPONSIBLE PERSON IMPLIES ACCEPTANCE OF THE SITE IN ITS EXISTING 9 8 4 4 4 4,04 ,04 0.09 1.00 2.00 CONDITION. � 9 15 ,0 ,0 0.05 1.00 2.00 8. MATCHED PRECIPITATION RATES: SPRINKLER HEADS SHALL HAVE MATCHED PRECIPITATION 5. LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR PREPARING ALL PLANTED AREAS. RATES WITHIN EACH CONTROL VALVE. 10 1 4,130 4,130 0.09 1.00 2.00 ALL DELETERIOUS MATERIAL SUCH AS ROCK, TRASH, CONSTRUCTION DEBRIS, AGGREGATE BASE MATERIAL, ASPHALT, ETC.., SHALL BE REMOVED PRIOR TO ANY FILL 9• IRRIGATION DISTRICTS: SPRINKLER HEADS IRRIGATING LAWN OR OTHER HIGH WATER Q J� 13,939 OPERATIONS. FINISH GRADES TO BE SMOOTH AND EVEN. GRADIENTS TO REMOVE LOW DEMAND AREAS SHALL BE CIRCUITED SO THAT THEY ARE ON SEPARATE ZONES FROM Q �Q, 11 1 22,123 EXCLUDES 25' BUFFER 0.32 2.00 2.00 AND HIGH POINTS AND TO PROVIDE POSITIVE DRAINAGE. THOSE IRRIGATING TREES, SHRUBS, OR OTHER REDUCED WATER DEMAND AREAS. op SEE STREET TREE CALC. kQ'P 11 8 9,109 9,109 0.21 1.00 2.00 6. FILL ALL PLANTING AREAS WITH CLEAN EARTHEN FILL, AS PER SPECIFICATIONS. SOIL 10. OVERSPRAY: SPRINKLER HEADS SHALL BE ADJUSTED TO REDUCE OVERSPRAY ONTO vi O� SHALL BE FREE OF HEAVY, STIFF CLAY AND ANY DELETERIOUS MATERIAL OVER ONE IMPERVIOUS SURFACES SUCH AS STREETS, SIDEWALKS, DRIVEWAYS, AND PARKING 11 13 2,862 2,862 0.07 0.00 0.00 INCH IN SIZE. REUSE EXISTING SURFACE TOPSOIL IF AVAILABLE. AREAS. N S 12 1 3,267 3,267 0.08 0.00 0.00 11. PRIOR TO COMMENCING WORK, CONTRACTOR TO CONFIRM PSI IS ADEQUATE TO z 7. TOPSOIL SHALL BE A LOOSE, FRIABLE, SANDY LOAM, CLEAN AND FREE OF TOXIC O 12 8 1,599 1,599 0.04 0.00 0.00 MATERIALS, NOXIOUS WEEDS, WEED SEEDS, ROCKS, GRASS, OR OTHER FOREIGN FURNISH AND INSTALL A COMPLETE IRRIGATION SYSTEM WHICH PROVIDES ADEQUATE N MATERIALS AND A PH OF 5.5 TO 7.0. IF ON-SITE TOPSOIL DOES NOT MEET THESE WATER COVERAGE TO ALL LAWN AND PLANTING AREAS. SHOULD THE PSI BE LESS g TOTAL OPEN SPACE TREES 7.00 10.00 MINIMUM STANDARDS, CONTRACTORS ARE RESPONSIBLE TO EITHER: PROVIDE APPROVED THAN ADEQUATE, NOTIFY THE ARCHITECT IMMEDIATELY. IN THE EVENT THAT THELu E.TOWER ST. IMPORTED TOPSOIL OR, AMEND THE ON-SITE TOPSOIL. ARCHITECT IS NOT NOTIFIED PRIOR TO THE START OF CONSTRUCTION, THE CONTRACTOR aC SHALL ASSUME FULL RESPONSIBILITY FOR ANY NECESSARY REVISIONS. STR E ET TR E E CALCULATIONS (1TR E E/35 LF) 8. TOPSOIL DEPTHS SHALL BE AS FOLLOWS (WHERE APPLICABLE): LAWN AREAS-6" MIN.; 12. WHERE APPLICABLE, LABEL ALL IRRIGATION RISERS, FAUCETS, VALVE BOXES, AND PLANTER BEDS - 12" MIN.; CURB ISLANDS - 18" MIN.ALL PLANTING BEDS SHALL BE VAULTS WITH DURABLE TAGS CARRYING THE WARNING "DANGER-UNSAFE WATER OR STREET NAME BUFFER LF CALC REQ PRVD NUMBER OF DRIVES TREATED WITH A PRE-EMERGENT HERBICIDE. NON-POTABLE WATER." WIDTH WIDTH PER PLAN w S. LOCUST GROVE RD. 25' 1,162 0 1,162 LF/35 33.00 33.00 9 FINISH GRADES FOR LANDSCAPE AREAS TO BE SMOOTH AND EVEN GRADIENTS WITH 13. INSTALL ALL PIPING AND VALVES IN PLANTING AREAS WHERE POSSIBLE, AND LOCATE Q POSITIVE DRAINAGE IN ACCORDANCE WITH SITE GRADING PLAN. SLOPES FOR TURF W v E. SPIRE ST. 13.5' 914 16 498 LF/35 14.00 18.00 AREAS SHALL NOT EXCEED 3:1. ELECTRIC CONTROL AND QUICK COUPLING VALVES IN GROUND COVER/SHRUB AREAS, w z E. INFLECTION ST. 13.5' 236 0 236 LF/35 7.00 9.00 6" TO 12" AWAY FROM EDGE OF PAVEMENT FOR EASE OF ACCESS. Q w 10. PRE-EMERGENT HERBICIDE SHALL BE APPLIED PER MANUFACTURER'S = Q E. AMBITION ST. 13.5' 1,775 21 629 LF/35 18.00 28.00 RECOMMENDATIONS AND SHALL OCCUR AFTER TOPSOIL PLACEMENT AND PRIOR TO 14. PROVIDE UNDERGROUND IRRIGATION SYSTEM AS A COMPLETE UNIT PRODUCED BY A ~ v INSTALLATION OF PLANT MATERIALS AND MULCH. SINGLE ACCEPTABLE MANUFACTURER, INCLUDING HEADS, VALVES, CONTROLS, AND z W w vi E. APOGEE ST. 13.5' 514 4 410 LF/35 12.00 12.00 ACCESSORIES. N S. ZENITH AVE. 13.5' 1,346 20 826 LF/35 24.00 26.00 11. ALL PLANT MATERIAL SHALL CONFORM TO THE AMERICAN NURSERYMAN STANDARDS FOR TYPE AND SIZE SHOWN. PLANTS WILL BE REJECTED IF NOT IN HEALTHY GROWING 15. A MIN. OF 4" POP-UPS ARE TO BE USED IN ALL LAWN AREAS. DRIP IRRIGATION TO S. STEEPLE AVE. 13.5' 469 5 339 LF/35 10.00 10.00 CONDITION. BE USED IN ALL PLANTER BEDS. APEX SOUTHEAST S. PEAK AVE. 13.5' 234 0 234 LF/35 7.00 7.00 W SUBDIVISION NO. 1 w S. CADENCE AVE. 13.5' S57 5 427 LF/35 12.00 12.00 12. ALL WRAPPING MATERIAL SHALL BE CUT AND REMOVED FROM AROUND THE UPPER 16. THE IRRIGATION CONTRACTOR IS RESPONSIBLE TO SIZE CIRCUIT PIPING. WATER LLi PORTION OF THE ROOT BALL. METAL BASKET WIRES AND BURLAP SHALL BE PULLED VELOCITY IN ALL PIPES SHALL NOT EXCEED FIVE FEET PER SECOND. MINIMUM PIPE a TOTA L STREET E ET TR E ES 137.00 155.00 BACK AND TUCKED UNDER THE EDGES OF THE SAUCER RINGS ON ALL TREES AND SIZE TO BE 1". zzzz Q w LARGE SHRUBS. ALL SYNTHETIC BURLAP SHALL BE REMOVED FROM ROOT BALLS W E. MOUNT MARIA ST. Lu a O E. MOUNT ARIA ST. MITIGATION REQUIREMENTS PRIOR TO BACKFILLING. 17. CONTRACTOR IS RESPONSIBLE FOR INSTALLING SLEEVES UNDER ALL ROADWAY, H PARKING, AND WALKWAY SURFACES. EXTEND 6" MINIMUM BEYOND SURFACE EDGE. w Vf Vf 13. ALL PLANT MATERIAL SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR BEGINNING IDENTIFY ENDPOINTS OF SLEEVING. Ln r7'1 fl'I Q AT THE DATE OF ACCEPTANCE BY OWNER. REPLACE ALL PLANT MATERIAL FOUND m m u THERE ARE NO HEALTHY TREES > 4" CAL. PROPOSED FOR REMOVAL DEAD OR NOT IN HEALTHY CONDITION IMMEDIATELY WITH COMPARABLE SIZE AND 18. ALL IRRIGATION HEADS LOCATED ADJACENT TO ROAD SURFACES NOT PROTECTED BY A N r r N SPECIES AT NO COST TO THE OWNER. VERTICAL CONCRETE CURB SHALL BE PLACED 18" FROM THE EDGE OF THE ROAD 25' w !" w PATHWAY TREES (1 TREE/100 LF) SURFACE. SEWER EASEMENT O O 14. FERTILIZE ALL TREES AND SHRUBS WITH AGRIFORM PLANTING TABLETS. QUANTITY PER PATHWAY MANUFACTURER'S RECOMMENDATIONS. 19. WHERE APPLICABLE, CONTRACTOR IS RESPONSIBLE TO PROVIDE 120 VOLT POWER AND BLOCK 7 BLOCK 3 BLOCK # LOT # LENGTH CALCULATION REQ PRVD ALL REQUIRED CIRCUITS FROM THE ELECTRICAL PANEL TO THE IRRIGATION CONTROLLER. 25 I 26 3 24 132 132 LF / 100 1.00 1.00 15. CONTRACTOR'S MAINTENANCE SHALL INCLUDE: SIZE WIRE AND CONDUIT AS REQUIRED. N 23 22 21 20 19 20 21 22 23 24 00 00 1 3 31 131 131 LF 100 1. . PRUNING, CULTIVATING, WEEDING, WATERING, AND APPLICATION OF APPROPRIATE 20. CONTRACTOR IS RESPONSIBLE TO REPAIR ALL EXISTING IRRIGATION COMPONENTS O 26 / 0 30 24 ' 25 27 I INSECTICIDES AND FUNGICIDES NECESSARY TO MAINTAIN PLANTS FREE OF INSECTS AND DAMAGED AS A RESULT OF NEW CONSTRUCTION, INCLUDING ADJACENT PROPERTIES. 27 3 37 131 131 LF / 100 1.00 1.00 DISEASE UNTIL FINAL ACCEPTANCE BY OWNER. REPAIR INCLUDES BUT IS NOT LIMITED TO PIPING, VALVES, HEADS, DRIP COMPONENTS, z E. SPIRE ST. CONTROL WIRES AND EQUIPMENT, AND SLEEVES. IF APPLICABLE, IRRIGATION CONTRACTOR 28 7 23 129 129 LF / 100 1.00 1.00 RE-SET SETTLED PLANTS TO A PROPER GRADE AND POSITION. SHALL ENSURE THAT THE EXISTING IRRIGATION SYSTEM REMAINS OPERABLE DURING °� 28 CONSTRUCTION AND THAT FOLLOWING CONSTRUCTION, THE EXISTING IRRIGATION SYSTEM O : 11 8 259 259 LF / 100 3.00 3.00 RESTORE PLANTING SAUCER AND ADJACENT MATERIAL AND REMOVE AND REPLACE OPERATES AS GOOD, OR BETTER THAN EXISTED PRIOR TO THIS PROJECT. N 29 w 7 6 5 5 6 7 : 29 DEAD MATERIAL. 21. CONTRACTOR SHALL REPLACE, AT NO ADDITIONAL COST TO THE OWNER, PLANT MATERIALS I„I„I O I ,. •;•; ,, •;•; Q : ` ; : TOTA L TR E ES REQUIRED/PROVIDED 151.0 172.0 TIGHTEN AND REPAIR GUY WIRES AND STAKES AS REQUIRED ONLY IF ORIGINALLY DAMAGED DURING EXECUTION OF THIS PROJECT OR DAMAGED DUE TO THE CONTRACTORS \� 0 LEI w FAILURE TO MAINTAIN OPERATION OF THE EXISTING SYSTEM DURING THE COARSE OF /_ J o _ $ ',Q 30 I NEEDED. CONSTRUCTION. Q O 25' N E. BINGLEY ST. z $ BLOCK 8 Y BLOCK 9 L .,v MITIGATION NOTE: THERE ARE NOT TREES LARGER THAN 4" CALIPER TO BE REMOVED. z 31 CORRECT DEFECTIVE WORK AS SOON AS POSSIBLE AFTER DEFICIENCIES BECOMES La U ARTERIAL LL' Q 4 w 22. LANDSCAPE ARCHITECT IS NOT RESPONSIBLE FOR DISCREPANCIES BETWEEN DESIGN m N w APPARENT AND WEATHER AND SEASON PERMIT. LANDSCAPE BUFFE I O O O O O O O a O O O O O O < DRAWINGS AND ACTUAL SITE CHARACTERISTICS. CONTRACTOR SHALL FIELD VERIFY ALL W I: 9 10 11 12 13 14 15 15 14 13 12 11 10 9 Q 32 INFORMATION PROVIDED ON DRAWINGS. CONTRACTOR SHALL STOP CONSTRUCTION AND z o MEASURED FROM 2 c� BACK OF CURB I vi :. CONTACT THE OWNER IMMEDIATELY FOR FURTHER DIRECTION IF DISCREPANCIES OCCUR. Q • O • ••• • • =• • •�� • � • • • • �•• • • •�• � • • •• � � 23. UPON COMPLETION AND PRIOR TO FINAL PAYMENT, THE IRRIGATION CONTRACTOR SHALL "' PLANT SCHEDULE , (~ U 25' Err� . AMBITION ST. O PROVIDE A NEAT AND LEGIBLE AS-CONSTRUCTED IRRIGATION PLAN, AN OPERATION AND C SEWER EASEMENT O MAINTENANCE MANUAL, AND UP TO 8 HOURS OF ORIENTATION AND/OR TRAINING FOR THE 0 20' 4 7 :;I 1 36 34 I TREES BOTANICAL/COMMON NAME SIZE MATURE HXW CLASS QTY OWNERS MAINTENANCE AND OPERATIONS STAFF. W W z .. - - ~ I IDAHO POWER 5I O 38 37 24. THE ENTIRE SYSTEM SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM THE DATE OF 3 O9 10 11 12 42 41 40 39 O OVERHEAD LINE $ ACER TRUNCATUM'PACIFIC SUNSET'TM 2"CAL. B&B 35'X25' CLASS II 20 IT'S ACCEPTANCE. REPAIR OR REPLACEMENT OF ANY DEFECTS OCCURRING WITHIN THAT YEAR Q O I I O 35 PACIFIC SUNSET MAPLE SHALL BE COMPLETED PROMPTLY BY THE IRRIGATION CONTRACTOR AT NO ADDITIONAL COST TO J g SETBACK. CLASS II 3 BLOCK 3 0 THE OWNER. TREES NOT BLOCK 11 1341a ALLOWED 19 I ;: 4 CARPINUS BETULUS 2"CAL. B&B 50'X40' CLASS II 23 25. CONTRACTOR SHALL PROVIDE, AT NO ADDITIONAL COST TO THE OWNER, SPRING START UP AND 0 w O BLOCK 10 EUROPEAN HORNBEAM WINTERIZATION DURING THE GUARANTEE PERIOD. x w 20 5 Q W 3 SEE L2.0 I 1 21 18 . .I w FRAXINUSAMERICANA'AUTUMN PURPLE' 2"CAL. B&B 50'X40' CLASS II 36 Q z AUTUMN PURPLE ASH WILLIAMS PIPELINE NOTES m m E. ADLER HOF+ST. 11111111111 J 0 E. ADLER HOF ST. Q V Z SEE L4.0 w 1. NO TREES ARE PERMITTED ON WILLIAMS RIGHT OF WAY. ADDITIONALLY, THE CANOPY OF ANY a I 22 1 w Q GLEDITSIATRIACANTHOS'IMPERIAL' 2"CAL. B&B 40'X35' CLASS II 40 TREES PLANTED ADJACENT TO THE RIGHT OF WAY MUST NOT EXTEND INTO THE RIGHT OF WAY Z U N. IMPERIAL HONEYLOCUST AT MATURITY. ANY BRANCHES EXTENDING INTO THE RIGHT OF WAY WILL BE SIDE CUT BY 3 I O vi WILLIAMS AT ITS DISCRETION. 23 `" APEX SOUTHEAST SUBDIVISION NO. 3 10 �• PYRUS CALLERYANA'REDSPIRE' 2"CAL. B&B 40'X25' CLASS II 12 2. WITH PRIOR APPROVAL FROM WILLIAMS, SOME TYPES OF LOW GROWING, SHALLOW-ROOTED o SHRUBS MAY BE PERMITTED ON THE RIGHT OF WAY PROVIDED THEIR MAXIMUM MATURE HEIGHT 24 O LLi REDSPIRE CALLERY PEAR WILL NOT EXCEED 5'AND ARE NOT WITHIN 5'OF THE EDGE OF THE PIPELINE. WILLIAMS o > REQUIRES THAT THE MATURE PLANTINGS WILL NOT PREVENT WILLIAMS REPRESENTATIVES FROM w •' O10Q SEEING DOWN THE RIGHT OF WAY DURING ROUTINE PATROLS OR WALKING DOWN THE RIGHT 25 Q U TILIA CORDATA'GREENSPIRE' 2"CAL. B&B 45'X35' CLASS II 23 OF WAY DIRECTLY OVER THE PIPELINES AS THEY PERFORM REQUIRED INSPECTIONS. UNDER BLOCK 12 z GREENSPIRE LITTLELEAF LINDEN NO CIRCUMSTANCES WILL MECHANICAL EQUIPMENT BE USED IN THE PLANTING OF SHRUBS. z w o M 9 I z O Q 3. WILLIAMS RESERVES THE RIGHT TO CUT AND/OR REMOVE PLANTINGS AS REQUIRED IN THE O N U EVERGREEN TREES BOTANICAL/COMMON NAME SIZE MATURE HXW CLASS QTY OPERATION, INSPECTION, AND MAINTENANCE OF ITS PIPELINE FACILITIES; FURTHER, WILLIAMS N vi ASSUMES NO RESPONSIBILITY FOR ANY COST INVOLVED IN THE REPLACEMENT OF SAID CUT Z li I 27 I `n O •• AND/OR REMOVED LANDSCAPE PLANTINGS. PICEA PUNGENS'HOOPSII' 6'-8'B&B 35'X15' 7 a I 28 I HOOPSI BLUE SPRUCE 4. ALL SPRINKLER OR IRRIGATION SYSTEMS WILL REQUIRE REVIEW BY A WILLIAMS REPRESENTATIVE. 0 : O7 SPRINKLER HEADS WILL NOT BE PERM r NXIW/i$ 39' PINUS FLEXI LIS'VAN DERWOLF'S PYRAMID' 6'-8'B&B 25'X15' EVERGREEN 11 CITY OF MERIDIAN E.ADVENTURE ST. VANDERWOLF'S PYRAMID PINE ACHD LANDSCAPE NOTES z EASEMENT ^ I I 1. TREES SHALL NOT BE PLANTED WITHIN THE 10' CLEAR ZONE OF ALL ACHD STORM II LLi GROUND COVERS BOTANICAL/COMMON NAME CONT QTY DRAIN PIPE, STRUCTURES, OR FACILITIES. O 0 a I 2. SEEPAGE BEDS MUST BE PROTECTED FROM ANY AND ALL CONTAMINATION DURING THE E N G I N E E R I N G 3 I I Q W W TURF SOD RHIZOMATOUS SOD 117,201 SF CONSTRUCTION AND INSTALLATION OF THE LANDSCAPE IRRIGATION SYSTEM. w 9233 WEST STATE STREET O RHIZOMATOUS TALL FESCUE BOISE, IDAHO 83714 o I I PHONE(208)639-6939 I..L �N kmengllp.com Z -op- E.VIA ROBERTO ST. OTHER BOTANICAL/COMMON NAME CONT QTY CONTACT INFORMATION DESIGN BY: KAC W op-op-op-op-op-op-op / u r DRAWN BY: KAC SHRUBS AND PERENNIALS NONE 75,145 OWNER LANDSCAPE CONSULTANT CHECKED BY: AY O Z BRIGHTON DEVELOPMENT INC. KM ENGINEERING, LLP DATE: APRIL 2021 2929 W. NAVIGATOR DR., STE. 400 9233 WEST STATE STREET LANDSCAPE SITE PLAN CONTDA : ZACH MEYERS PHONE: (208) 639-6939 ICTO 83642 BOISE, IDAHO 83714 PROJECT: 21-021 w 0 150 300 450 PHONE: (208) 378-4000 FAX: (208) 639-6930 SHEET NO. Q Z FAX: (208) 377-8962 CONTACT: ALYSSA YENSEN, PLA w Plan Scale: 1" = 150' EMAIL: zmeyers®brightoncorp.com EMAIL: ayensen@kmengllp.com L1.0 0 Y u z 25' ICI �•`•`,,,C$OFID i�4i ARTERIAL LANDSCAPE I N — 12 BUFFER MEASURED _ ••,• c�• ••••••••� ,,, • SSA YELL;•. • FROM FUTURE BACKT! ' II�II OF CURB 1 4"PI 4"PI 4"PI 25 4"PI 4'Pl y 4"{yl 4"PI�4 I 4�PI 4"PI fl"PI 4"PI-1"PI "� PI PLANT SCHEDULE s • _ • �IIIISEWER EASEMENTy Q0 BLOCK 7IDAHO POWER OVERHEI _ O 0D� •� ��•.• 411/21 ••• i,, •.` 20' 25 y y :• A 165,7 •• LINE SETBACK. CLASS II IN I I I y I j 0ACER TRUNCATUM 'PACIFIC SUNSET'TM 2"CAL.B&B 35'X25' CLASS II 20 ,,�ii L •••••••• e'4••• y ' II�� I y y C w PACIFIC SUNSET MAPLE •••j��,D;;;4��.•`� TREES NOT ALLOWED I I Lu Lu JI II I y p y I y y 21 20 19 � CARPINUS BETULUS 2"CAL.B&B 50'X40' CLASS II 23 23 y 22 O O O N C1 EUROPEAN HORNBEAM y vi y S Uj y u II I s y y y FRAXINUS AMERICANA'AUTUMN PURPLE' 2"CAL.B&B 50'X40' CLASS II 36 y yll I _ I y AUTUMN PURPLE ASH s I p °° y 1�41 ° I ( I y y III 24 I y y 10 GLEDITSIA TRIACANTHOS IMPERIAL" 2"CAL.B&B 40'X35' CLASS II 40 Lu WI I y 11 30 a 1 y y I IMPERIAL HONEYLOCUST y y 0 IRR a 4"PI 4"PI 4"PI NJ ° U y , . •• PYRUS CALLERYANA'REDSPIRE' 2"CAL.B&B 40'X25' CLASS II 12 27 y REDSPIRE CALLERY PEAR d • I I I �' •f y y y y •y • y 'Y • 'Y 'L 'Y 'Y 'Y 'Y •'Y N � - y s"w 8 N 8 w 8 s w w s w 8 w s w s w o TILIA CORDATA•GREENSPIRE' 2"CAL.B&B 45'X35' CLASS II 23 12 GREENSPIRE LITTLELEAF LINDEN 11 4 E. SPIRE ST. 1 p „ s"s a"s s" s"s s°s a"s a"s s"s a"s s"s "s a"s WI I EVERGREEN TREES BOTANICAL/COMMON NAME SIZE MATURE HXW CLASS QTY If 28 o Ov :9 _ _ _ _° 1 8_ _ _ _ PICEA PUNGENS•HOOPSII' 6'-8' B&B 35'X15' 7 3 I 14 1 y y u HOOPSI BLUE SPRUCE N WI I I I I III •1 y N y r I \1U W w y , 6 I I I I I y w I o PINUS FLEXILIS'VANDERWOLF'S PYRAMID' 6'-8' B&B 25'X15" EVERGREEN 11 L v nt VANDERWOLF'S PYRAMID PINE al I I y I I o0 WI I I y CY 29 S y y I GROUND COVERS BOTANICAL/COMMON NAME CONT QTY I ++ I $ o wl 1 I y y y 'k O O O I y y TURF SOD RHIZOMATOUS SOD 117,201 SF N I I RHIZOMATOUS TALL FESCUE 1i y�' y Y Y 'Y •Y •Y Y y A I W • 'Y y W 'Y : 'Y 'L 'Y �L y I Q •• WI I •a — y y y y -y I y I L Q OTHER BOTANICAL/COMMON NAME CONT QTY O n z �, y •y • y y 'Y •l• y 8 •• - v y vi SHRUBS AND PERENNIALS NONE 75,145 o —J > Q a 8"w 8"w "w 8'w s"w s"H Q : IV W 5 E. BINGLEY ST. S — — — W 2 I 2 ~ 4"PI 4"�' 4" BLOCK 8 4"PI 4"PI 4"PI 4"PI 4"PI 4"PI 4"PI 4"PI 4"PI PI s 3" "$ 8"S 8"S 8"S 8"S 8"S w I y y y N - W •• U OS � ° y U1 y . y W I • S 0 •• I � y yl y .�: y •s y .�• y y : y wl� I �` 4"PI 4 1 4"PI 4" y 'PI f 4 1 y ' N y, y O9 10 11 12 13 14 15 I ° y 8 y I W y KEY NOTES (TYPICAL) W y O S= y y y y y ' 1. INSTALL 3' DIAMETER SHOVEL CUT TREE RING, WITH BARE EARTH SURFACE AT ALL y I C°1 S I y y y TREES WITHIN TURF AREAS. b z y y 2. 40' CLEAR VISION TRIANGLE. NO TREES SHALL BE PLANTED WITHIN A CLEAR VISION LL I y I w ;y y TRIANGLE. THE MAXIMUM HEIGHT OF ANY VEGETATIVE GROUND COVER AT MATURITY z y y y ' WITHIN THE CLEAR VISION TRIANGLE SHALL BE 3' FROM THE ADJACENT STREET GRADE. 0 y I © V1 \ y •. II� — - - -ILI - - - - - - — - - - — - - - - — - - - — — y I S J. 3. ALL PLANTED BEDS TO RECEIVE A MIN. 3" DEPTH ORGANIC PERMABARK MULCH WITH 0 z CO S , S S , S °� PERMEABLE FABRIC WEED BARRIER. SUBMIT SAMPLE TO OWNER FOR APPROVAL PRIOR IIIII O � S � • � T Q y y `4 y y y• y y y a y y y y y • y y y ' y y y y � � 2 TO ORDERING AND INSTALLING. THE USE OF MULCH OR ROCK AS THE ONLY GROUND > y 1 $ "w s„w s"w „ "w w s„w „w s„ s„w s„ „w COVER IN REQUIRED PLANTING ARES IS PROHIBITED. IMPERMEABLE PLASTIC WEED — Q J ' BARRIERS ARE PROHIBITED. Q IIII s $"s s"s 8"s s"s s"s $"s s"s 8"s 8' —E. AMBITION ST. 8"S s"S 8" 8"S 8"S O 4. TREES PLANTED IN PARK STRIPS TO BE CENTERED IN STRIP. Co — Lu ° s . J 5. 10' ACHD FACILITY CLEAR ZONE. TREES SHALL NOT BE PLANTED WITHIN THE 10' (� Z Q II III I W� y y • y y y y y y y y • y y y y • y y y y y .y y y W CLEAR ZONE OF ALL ACHD STORM DRAIN PIPES, STRUCTURES, OR FACILITIES. Q U S — — — — . d 6. INSTALL FLAT—BLADE SHOVEL EDGING AT INTERFACE OF SOD AND PLANTER BED. SEE (� Q m I I y = L4.0-2. Q y I 25' ° I y r I y y y y y y y y w y .. a �Y N I 4"P 4"PI 4"PI W z 0 7 r y IL SEWER EASEMENT 7a I y yp i I W 7. GRAVEL SHOULDER PER CIVIL PLANS. = w IIIY y y 4w ° N 8. 6 TALL CEDAR FENCE. MATCH PREVIOUS PHASE. SEE L4.0-4. J y I S } O Id z 9. 5' TALL CLEAR VISION METAL FENCE. MATCH PREVIOUS PHASE. SEE L4.0-3. 0 IIy S 6 I I O s3 I l y I y l y 4 10. 5' MICRO PATHWAY. SEE CIVIL PLANS. (� y w p I O 10 11 12 y U 11. +/-3' LANDSCAPE BERM. MATCH PREVIOUS PHASE. x Lu 12. EXISTING LANDSCAPING AND IRRIGATION TO REMAIN. RETAIN, PROTECT, AND OR CL g y C ADJUST AS SHOWN. CONTRACTOR SHALL FIELD VERIFY LIMITS OF DISTURBANCE AND Q y I I I y I 8 vcl� I c PATCH BACK ALONG PHASE BOUNDARY AS NECESSARY. TRANSITION BETWEEN NEW E y 1 y I y I s Co y O AND EXISTING LANDSCAPE SHALL BE NON RECOGNIZABLE AND COHESIVE WHEN a I I 16 s I — y y° d FINISHED. CONTRACTOR IS RESPONSIBLE TO REPAIR ALL EXISTING LANDSCAPE 3 O y �y I I PLANTING AREAS AND IRRIGATION COMPONENTS DAMAGED AS A RESULT OF NEW y CONSTRUCTION. THE CONTRACTOR SHALL ENSURE THAT THE EXISTING IRRIGATION II I IIII I •y , y I °D y ' SYSTEM REMAINS OPERABLE DURING CONSTRUCTION AND THAT FOLLOWING CONSTRUCTION, THE EXISTING IRRIGATION SYSTEM OPERATES AS GOOD, OR BETTER I I BLOCK 11 13 y y THAN EXISTED PRIOR TO THIS PROJECT. CONTRACTOR SHALL REPLACE, AT NO 4"PI 4"PI 4"PI 4"PI�4 y 4" I 4"P 4' I 4"PI "PI > I ' ADDITIONAL COST TO THE OWNER, PLANT MATERIALS DAMAGED DURING EXECUTION OF yI I y y •• 1 y y Q y O THIS PROJECT OR DAMAGED DUE TO THE CONTRACTORS FAILURE TO MAINTAIN W • I °, OPERATION OF THE EXISTING SYSTEM DURING THE COURSE OF CONSTRUCTION. Id z a v `W a r O 19 s y y L z I w 10 I N y l o I I I • y vi Z � II I I I y• y y CoBLOCK 10 � , 1 ps I y y y I 17 16 15 14 �y I y W Ls- Id 0 Co Vl y 0 w � p S• • ' � � pl II 1 w 18 1 I \ y I E N G I N E E R I N G I y y J8E 4, s ' 9233 WEST STATE STREET 3 I BOISE, IDAHO 83714 O ° p I s< s S s- o y 6 Id PHONE(208)639 6939 LL ~ I„GI I I 21 S� °I �� y y • 'Y 'Y y 'Y t 'Y 'Y • 'Y .r W• w .V• 'Y 'Y 2 00 y I 9 kmengllp.com Q w II I 8"w 8"w 8 1 DESIGN BY: KAC LLJ ° y ° .I I I .I p y a E. ADLER OF ST. y r A ' DRAWN BY: KAC / CHECKED BY: AY O MATCH LINE - SEE SHEET L4.0 oC w DATE: APRIL 2021 Y LANDSCAPE PLAN PROJECT: 21 021 SHEET NO. Q Z 0 40 80 120 L2.0 0 Y Plan Scale: 1" = 40' z 1 ••••`,•e,C$0F!1)4 �.` •• AY C0 4"PI 4"PI 4' 4"Pi 4"PI 4"PI 4"PI 4"PI 4"PI 7PI 4"PI 4"PI r r PLANT SCHEDULE Z BLOCK 3 TREES BOTANICAL/COMMON NAME SIZE MATURE HXW CLASS CITY -165 C� ,004 .W 26 ACER TRUNCATUM 'PACIFIC SUNSET'TM 2"CAL.B&B 35'X25' CLASS II 20 0�i l 0 00 e' •, W PACIFIC SUNSET MAPLE ���i���,D;;;4,•�•`•� ui 0 Q 20 21 22 23 W W w CARPINUS BETULUS 2"CAL.B&B 50'X40' CLASS II 23 24 EUROPEAN HORNBEAM Lu z W 0 N I ° ° FRAXINUS AMERICANA'AUTUMN PURPLE' 2"CAL.B&B 50'X40' CLASS II 36 a m AUTUMN PURPLE ASH Q a u N W 25 / 27 0 GLEDITSIA TRIACANTHOS•IMPERIAL 2"CAL.B&B 40'X35' CLASS II 40 ° `' Lu IMPERIAL HONEYLOCUST v v ` ¢p W W d �• PYRUS CALLERYANA'REDSPIRE' 2"CAL.B&B 40'X25' CLASS II 12 REDSPIRE GALLERY PEAR W ° ° 8 W 8 W BrrW 8 W 8„W 8, 8„W 81r 8„W 8„ 8„W W a � o TILIA CORDATA'GREENSPIRE' 2"CAL.B&B 45'X35' CLASS II 23 12"SD 12 E. SPIRE ST. 4 GREENSPIRE LITTLELEAF LINDEN -8'S S 8"S 8"S 8"S 8"S 8"S 8"S 8"S 8"S "S " 8"S s 3 3 3 5 EVERGREEN TREES BOTANICAL/COMMON NAME SIZE MATURE HXW CLASS CITY e m z — — — — — — — — — — v v \ •• PICEA PUNGENS•HOOPSII' 6'-8' B&B 35'X15' 7 v\ s HOOPSI BLUE SPRUCE N Lu �� Lu W W �1�ir Lu C ,a 1 Cie PINUS FLEXILIS'VANDERWOLF'S PYRAMID' 6'-8' B&B 25'X15' EVERGREEN 11 I Q o VANDERWOLF'S PYRAMID PINE I W 29 W s S GROUND COVERS BOTANICAL/COMMON NAME CONT CITY OO O W O I W TURF SOD RHIZOMATOUS SOD 117,201 SF W W W RHIZOMATOUS TALL FESCUE LJ W W I 12 (� 0 I 9 OTHER BOTANICAL/COMMON NAME CONT CITY z < I $ Lu 8 W S SHRUBS AND PERENNIALS NONE 75,145 W •Y � 8 4 1 "PI 4""PI 4'PI —4"PII 4"PI 4"PI 4"PI 4' 4" BLOCK 9 4"PI 4"PI 4"PI 4"PI W Q V y •Y 1 PI W W W >�4 Q W s w "PI��e�4'�DI��r 4"PI-*-- 4'PI •W ®' I @,� Coe"s. 8' 31 .a8" Lu O W W W W •Y° •Y •Y W W ° I .� rAY► . O �� .� W I � W sI 8 1541 14 13 12 11 10 O9 W W 1 °° W W ae 320, KEY NOTES (TYPICAL) ® fV 9 ' 00 1. INSTALL 3' DIAMETER SHOVEL CUT TREE RING, WITH BARE EARTH SURFACE AT ALL 8 W W TREES WITHIN TURF AREAS. o ' J I ° 2. 40' CLEAR VISION TRIANGLE. NO TREES SHALL BE PLANTED WITHIN A CLEAR VISION z - TRIANGLE. THE MAXIMUM HEIGHT OF ANY VEGETATIVE GROUND COVER AT MATURITY z WITHIN THE CLEAR VISION TRIANGLE SHALL BE 3' FROM THE ADJACENT STREET GRADE. o y J W s / 3. ALL PLANTED BEDS TO RECEIVE A MIN. 3" DEPTH ORGANIC PERMABARK MULCH WITH o z r J J J J J PERMEABLE FABRIC WEED BARRIER. SUBMIT SAMPLE TO OWNER FOR APPROVAL PRIOR Ln • � `r 1 w 111� �.• W W `� ! • ( :2 TO ORDERING AND INSTALLING. THE USE OF MULCH OR ROCK AS THE ONLY GROUND 5 33 COVER IN REQUIRED PLANTING ARES IS PROHIBITED. IMPERMEABLE PLASTIC WEED \tw s w 8 „w s w a w s w 8"w s" w 8 Q s BARRIERS ARE PROHIBITED. ^ Q —8 S 8 S 8 S 8 S 8 5 "S "S 8" 8"S 81, s �� S C Lu ' E. AMBITION ST. 4. TREES PLANTED IN PARK STRIPS TO BE CENTERED IN STRIP. Co — W N 2 5 °v 1 4 y ° o W 3 a ° 5. 10 ACHD FACILITY CLEAR ZONE. TREES SHALL NOT BE PLANTED WITHIN THE 10' (� Z mW -k �� 2e : , �• W• a ° CLEAR ZONE OF ALL ACHD STORM DRAIN PIPES, STRUCTURES, OR FACILITIES. Q U LuJ 1 y • W s° 6. INSTALL FLAT-BLADE SHOVEL EDGING AT INTERFACE OF SOD AND PLANTER BED. SEE L Q Ln T ' oi Ln ° L4.0-2.N Q 4 4PI 4P 4PI PI 4 w w W 7. GRAVEL SHOULDER PER CIVIL PLANS. Lu z o Lu 1 36 -4 34 = Lu Q 1 8. 6' TALL CEDAR FENCE. MATCH PREVIOUS PHASE. SEE L4.0-4. J 8 W 8 z I 9. 5' TALL CLEAR VISION METAL FENCE. MATCH PREVIOUS PHASE. SEE L4.0-3. o 37W a 10. 5' MICRO PATHWAY. SEE CIVIL PLANS. (� w w U ' 42 41 40 39 38 W W 11. +/-3' LANDSCAPE BERM. MATCH PREVIOUS PHASE. W Y Q I W W W 12. EXISTING LANDSCAPING AND IRRIGATION TO REMAIN. RETAIN, PROTECT, AND OR o ' •1 ADJUST AS SHOWN. CONTRACTOR SHALL FIELD VERIFY LIMITS OF DISTURBANCE AND Q > PATCH BACK ALONG PHASE BOUNDARY AS NECESSARY. TRANSITION BETWEEN NEW rtd— — 1 W 10 W 35 AND EXISTING LANDSCAPE SHALL BE NON RECOGNIZABLE AND COHESIVE WHEN a ' 1 FINISHED. CONTRACTOR IS RESPONSIBLE TO REPAIR ALL EXISTING LANDSCAPE g LLi BLOCK 3 PLANTING AREAS AND IRRIGATION COMPONENTS DAMAGED AS A RESULT OF NEW > I CONSTRUCTION. THE CONTRACTOR SHALL ENSURE THAT THE EXISTING IRRIGATION ' w 1 W W SYSTEM REMAINS OPERABLE DURING CONSTRUCTION AND THAT FOLLOWING o z CONSTRUCTION, THE EXISTING IRRIGATION SYSTEM OPERATES AS GOOD, OR BETTER ' 0 4"Pi -4"PI 4"PI 4"FI=477rpi 4"PI 4"FI "PI 4"Pi 4"PI a"PI 4„Pi 4'PI THAN EXISTED PRIOR TO THIS PROJECT. CONTRACTOR SHALL REPLACE, AT NO ADDITIONAL COST TO THE OWNER, PLANT MATERIALS DAMAGED DURING EXECUTION OF Ln a THIS PROJECT OR DAMAGED DUE TO THE CONTRACTORS FAILURE TO MAINTAIN ' u OPERATION OF THE EXISTING SYSTEM DURING THE COURSE OF CONSTRUCTION. Z Id a N z Z o z Z o V u OC 0 Z N � z w o Y ' E N G I N E E R I N G 9233 WEST STATE STREET d o 3 ' BOISE, IDAHO 83714 0 0 PHONE(208)639-6939 LL N ' kmengllp.com Q z DESIGN BY: KAC L.L.I oE. ADLER HOF ST. DRAWN BY: KAC CHECKED BY: AY o z DATE: APRIL 2021 Y PROJECT: 21-021 z LANDSCAPE PLAN SHEET NO. Q w Z 0 40 80 120 L3.0 0 Y Plan Scale: 1" = 40' z MATCH LINE - SEE SHEET L2.0 P�EOFI'D ••, C ••.••••••� yo••,, 8.,s E. ADuLER HOF ST�,.s �5., �$„s s " so I ,* v�SSAY12 00* I I I KEY NOTES (TYPICAL) ® PLANT SCHEDULE NOTE: FOR FULL PLANTING SCHEDULE SEE L1.0.X AN 12 I _ 1. INSTALL 3' DIAMETER SHOVEL CUT TREE RING, WITH BARE EARTH SURFACE AT ALL TREES BOTANICAL/COMMON NAME SIZE r 1 '` s C F TREES WITHIN TURF AREAS. 10 cli �J,:• A 165;'7 •. I° • w y W W W w w w w 1 w W w w w w w w w W I • �I� •••••••• 22 W 4"Pi 4"Pi 44 PI- I 2. 40' CLEAR VISION TRIANGLE. NO TREES SHALL BE PLANTED WITHIN A CLEAR VISION ACER TRUNCATUM 'PACIFIC SUNSET'TM 2"CAL.B&B ,� L44 TRIANGLE. THE MAXIMUM HEIGHT OF ANY VEGETATIVE GROUND COVER AT MATURITY PACIFIC SUNSET MAPLE ••0 088888;lot ',��•• WITHIN THE CLEAR VISION TRIANGLE SHALL BE 3' FROM THE ADJACENT STREET GRADE. s I W I 1 8 I 3. ALL PLANTED BEDS TO RECEIVE A MIN. 3" DEPTH ORGANIC PERMABARK MULCH WITH CARPINUS BETULUS 2"CAL.B&B I s° I — — — EUROPEAN HORNBEAM W PERMEABLE FABRIC WEED BARRIER. SUBMIT SAMPLE TO OWNER FOR APPROVAL PRIOR TO ORDERING AND INSTALLING. THE USE OF MULCH OR ROCK AS THE ONLY GROUND s • + • 2 COVER IN REQUIRED PLANTING ARES IS PROHIBITED. IMPERMEABLE PLASTIC WEED 5 BARRIERS ARE PROHIBITED. C) FRAXINUS AMERICANA'AUTUMN PURPLE 2"CAL.B&B AUTUMN PURPLE ASH p I I 23 W00I 4. TREES PLANTED IN PARK STRIPS TO BE CENTERED IN STRIP. LLi GLEDITSIA TRIACANTHOS IMPERIAL' 2"CAL.B&B 5. 10' ACHD FACILITY CLEAR ZONE. TREES SHALL NOT BE PLANTED WITHIN THE 10' ui O IW I N y ' I 0 Q CLEAR ZONE OF ALL ACHD STORM DRAIN PIPES, STRUCTURES, OR FACILITIES. IMPERIAL HONEYLOCUST C�7 I I Lu W 9 I a 6. INSTALL FLAT-BLADE SHOVEL EDGING AT INTERFACE OF SOD AND PLANTER BED. SEE I I y I w L4.0-2. •• PYRUS L SPIRE' 2"CAL.B&B F I I II I a W N 4 REDSPIRE GALERY PEAR O 3O N 7. GRAVEL SHOULDER PER CIVIL PLANS. 00 _pt 8. 6' TALL CEDAR FENCE. MATCH PREVIOUS PHASE. SEE L4.0-4. TILIA CORDATA'GREENSPIRE' 2"CAL.B&B s I GREENSPIRE LITTLELEAF LINDEN W 9. 5' TALL CLEAR VISION METAL FENCE. MATCH PREVIOUS PHASE. SEE L4.0-3. EVERGREEN TREES BOTANICAL/COMMON NAME SIZE ° I I �; 10. 5' MICRO PATHWAY. SEE CIVIL PLANS. — z U. 11. +/-3' LANDSCAPE BERM. MATCH PREVIOUS PHASE. PICEA O 1 3 I I 0, .1 1 O I U. HOOPSI BLUE SPRUCE OOPSII' 6' 8' B&B N s 12. EXISTING LANDSCAPING AND IRRIGATION TO REMAIN. RETAIN, PROTECT, AND OR > W ° III 25 Q ADJUST AS SHOWN. CONTRACTOR SHALL FIELD VERIFY LIMITS OF DISTURBANCE AND �Wwv, L 6 I I I1 I I PATCH BACK ALONG PHASE BOUNDARY AS NECESSARY. TRANSITION BETWEEN NEW PINUS FLEXILIS'VANDERWOLF'S PYRAMID' 6' 8' B&B AND EXISTING LANDSCAPE SHALL BE NON RECOGNIZABLE AND COHESIVE WHEN • w I FINISHED. CONTRACTOR IS RESPONSIBLE TO REPAIR ALL EXISTING LANDSCAPE VANDERWOLF'S PYRAMID PINE 7 N PLANTING AREAS AND IRRIGATION COMPONENTS DAMAGED AS A RESULT OF NEW zi _vi ° BLOCK 12 CONSTRUCTION. THE CONTRACTOR SHALL ENSURE THAT THE EXISTING IRRIGATION GROUND COVERS BOTANICAL/COMMON NAME CONT s I N SYSTEM REMAINS OPERABLE DURING CONSTRUCTION AND THAT FOLLOWING 11 I I I I CONSTRUCTION, THE EXISTING IRRIGATION SYSTEM OPERATES AS GOOD, OR BETTER THAN EXISTED PRIOR TO THIS PROJECT. CONTRACTOR SHALL REPLACE, AT NO W s �` I ADDITIONAL COST TO THE OWNER, PLANT MATERIALS DAMAGED DURING EXECUTION OF TURF SOD OUSRHIZ TALL FESCOUSUE SOD 5 s I THIS PROJECT OR DAMAGED DUE TO THE CONTRACTORS FAILURE TO MAINTAIN RHIZOMATOUS TALL FESCUE I I I 26 I W O OPERATION OF THE EXISTING SYSTEM DURING THE COURSE OF CONSTRUCTION. ~ I I I I I y OTHER BOTANICAL/COMMON NAME CONT I I I I sl I z SHRUBS AND PERENNIALS NONE III I I�I � I I N y l I I 0 ° I� 0 • I 0 � W I I� W I REMOVE DEAD/ DAMAGED BRANCHES AND PRUNE TO V INTERNATIONAL SOCIETY OF I1I'� I I u, N . I ARBORICULTURE STANDARDS; I I IMPROPERLY PRUNED TREES I�I 28 I I 00 DETERMINED B E p LANDSCAPE ARCHITECT) I I � • III I 8 I I 7 p 0 O SHALL BE REMOVED AND s'-0„ f V (2)-BVC WOOD TREE p o o REPLACE. O L_ J of I° I $ I� STAKES(MIN. 6' HT) O TRUNK FLARE. LOCATE PRIOR CHAINLOCK �O�O o TO PLANTING. FLARE SHALL z "W TREE TIES O BE VISIBLE AFTER PLANTING. (/yQ�� W W 6" MULCH PER PLAN KEEP z s ::;19s \ W W W Y \ Y W Y W W 3„ MIN 1"-2" AWAY FROM TRUCK O F i POST CAP 4" APPART (CLEAR) MIN. STEP = 2" s FLARE 2" STEEL POST 2" METAL 2 1 STEEL TUBE RAILS _ 39' FINISH GRADE MAX. STEP = 12" (� O z u, CITY OF MERIDIAN S\ 3' MULCH AT cv \ EASEMENT \ ROOT- o I= BERM WATERING BASING PLANTER / E. ADVENTURE ST. BALL =II _ TURF 8" BEDS DEPTH _ — FERTILIZER TABLETS m C m WFOLD BACK BURLAP FROM TOPOF ROOTBALL.PLAN zQ BASKET.REMOVE WIRE NOTE: REMOVE TREATED ROOT- ^� UBACKFILL SOIL MIX GENTLY X 0 40 80 120 BALL j , —_ o m OR SYNTHETIC BURLAP WIDTH PACK BACKFILL USING WATER I I I —� �- ,, , o —I I �- I 0 Q Plan Scale: 1" = 40' COMPLETELY. REMOVE TO SETTLE SOIL AROUND I I —� I I I—I I I -III- I MULCHANY OIL AWAY AND/OR FROM 8" MIN 8" MIN ROOTBALL FINISH —I I i I—I —� �_�_I _ =1 I I �=I W z ° TREE CROWN AFTER PLANTING PIT ROOTBALL ON UNDISTURBED GRADE —III �I I II II I II I I=1 I — I TOPSOIL = V,J PIT SHALL BE A MIN. 2 TIMES WIDER SOIL -III I I S Q INSTALLATION. THAN ROOTBALL AT BASE AND A G J MIN. 3 TIMES WIDER THAN ROOTBALL CUT EDGE AT FINISH GRADE. DEPTH SHALL BE NOTES: SAME AS THE ROOTBALL. O 1. THE CONTRACTOR IS RESPONSIBLE TO INSURE THAT ALL TREES ARE PLANTED STRAIGHT AND THAT THEY REMAIN STRAIGHT FOR A MINIMUM OF 1 YEAR. ALL 112 1' SQUARE STEEL (1) 1" STEEL TUBE x } STAKING SHALL BE REMOVED AT THE END OF THE ONE YEAR WARRANTY PERIOD. RODS 4" APPART (CLEAR) BOTTOM RAIL L u DECIDUOUS TREE PLANTING AND STAKING DETAIL SHOVEL CUT EDGE 5'-FOOT CLEAR VIEW METAL FENCE Q NTS NTS NTS 2 w 3 a z 3 8'_0" 8'-0" 8'-0" 7 —82 7 —82> 4X6 R.S. CEDAR 4X6 R.S. CEDAR POST ON-CENTER SPACING 0 LEVEL PANEL POST ON-CENTER SPACING ® STEPPED PANEL a POST @ CORNERS 1X6 R.S. CEDAR POST ® CORNERS 1X6 R.S. CEDAR AND STREET FACING AND STREET FACING ti 3/4" CHAMFER OVERLAPING PICKETS 3/4" CHAMFER OVERLAPING PICKETS 4X4 R.S. CEDAR 3/4" CHAMFER 4X4 R.S. CEDAR 5-1/2" MIN. STEP TOP RAIL ® STEPPED PANEL TO X4 R.S. CEDAR o SECTIONS (TYP) a POST TYP (1" OVERLAP) SECTIONS (TYP.) 0 POST TYP.) (1" OVERLAP) @ POST (TYP.) EXTEND TO FAR EDGE OF POST (TYP.) ( POST (TYP.) POST (TYP.) POST (TYP.) G ® EACH END (TYP.) z 1X6 R.S. CEDAR TRIM 2X6 R.S. CEDAR TOP RAIL 2X6 R.S. CEDAR TOP RAIL �� 12" MAX. STEP - SHORTEN z z PANEL IF NECESSARY 2X6 R.S. CEDAR TOP RAIL O Lt o POST u v�i in U)Cn 4X4 R.S. CEDAR 3/4" CHAMFER z z I (TYP.) 0 POST (TYP.) N _ 0 4X6 R.S. CEDAR _ 0 z o POST (TYP.) J o U w0 w 0 2X6 R.S. CEDAR TOP RAIL U J J J o 0 2X4 R.S. CEDAR MIDDLE RAIL 2X4 R.S. CEDAR MIDDLE RAIL z 2X4 R.S. CEDAR MIDDLE RAIL O va c, U- w U U � 0 � � ENGINEERING a _ 0 ATTACH PICKETS TO SUPPORT - 0 a - u RAILS WITH 2 16d GALV, o a 0 o I `" RING-SHANK(NAILS ® TOP, I � Cl) 2X4 R.S. CEDAR MIDDLE RAIL I J 3 J ¢ MIDDLE AND 90TTOM. a co 9233 WEST STATE STREET o o N a BOISE, IDAHO 83714 O o PHONE(208)639-6939 LL kmengllp.com Q G 1X6 R.S. CEDAR TRIM 2X6 R.S. CEDAR BOTTOM RAIL 2X6 R.S. CEDAR BOTTOM RAIL 2X6 R.S. CEDAR BOTTOM RAIL DESIGN BY: KAC w w OFFSET OFFSET \ 1 DRAWN BY: KAC / 0 I:" ATTACH EACH END OF MIDDLE RAIL WITH (1) o 1 ATTACH EACH END OF TOP AND BOTTOM RAIL WITH SLOPE BOTTOM RAIL 2X6 R.S. CEDAR BOTTOM LATTACH TOP AND BOTTOM r �,Y;;•-1 16d GALV. RING-SHANK NAIL AND (1) #10 (2) 16d GALV. RING-SHANK NAILS AND (1) #10 TO MATCH GRADE RAIL CHECKED BY: AY O _ SCREW - STAINLESS STEEL OR COATED. SCREW - STAINLESS STEEL OR COATED. WITH 3" OFFSET 1X6 R.S. CEDAR TRIM WITH (12) 16d GALV. a �'(• �:=1 i. .. OVERLAPING PICKETS DATE: APRIL2021 RING-SHANK NAILS. TOE-NAIL ® CORNERS WITH (1" OVERLAP) Y TYPICAL RAIL FASTENERS PROJECT: 21-021 FENz ANDCSETOST SET ON GRAVEL WTH CONCRETE (TYP.) SHEET NO. Q z WOODEN FENCE w 4NTS L4.0 p z V