Loading...
CC - Street Light Plan MUSGROVE %'�� THE ENGINEERING,P.A. �� ��� 234 S.Whisperwood Way .I. LAND ELECTRICAL LEGEND ELECTRICAL Bo208.34.058509 . 208.384.0585 www.musgrovepa.com GROUP ABBREVIATIONS OVER 40 YEARS OF EXCELLENCE COMcheck Software Version 4.i.3.o LIGHTING Proieallo. 19-359 Exterior Lighting Compliance Certificate REFERENCE FIXTURE SCHEDULE FOR MOUNTING TYPE,MOUNTING HEIGHT, A AMPERES AND FIXTURE TYPE. AC 6"ABOVE BACKSPLASH AFF ABOVE FINISHED FLOOR Project Information -❑ POLE LIGHT, 1 HEAD WITH POLE AFG ABOVE FINISHED GRADE Energy Code: 2015 IECC AF AMP FRAME 1013012020,E Project Title: Eagle Commons at Ustick and Eagle ❑- 0 POLE LIGHT,2 HEADS WITH POLE AIC AMPS INTERRUPTING CAPACITY Project Type: New Construction AT AMP TRIP ATS AUTOMATIC TRANSFER SWITCH Exterior Lighting Zone 2(Neighborhood business district) ® HISTORIC POLE LIGHT WITH POLE AWG AMERICAN WIRE GAUGE BD BOTTOM OF DECK ELECTRICAL GENERAL NOTES Construction Site: Owner/Agent: Designer/Contractor: BS BOTTOM OF STRUCTURE Wadsworth Development Group Musgrove Engineering DEVICES 3085 E Ustick Road 234 S Whisperwood Way C CEILING MOUNTED Meridian, ID Boise, ID 83709 C CONDUIT 208-384-0585 CB CIRCUIT BREAKER A. THESE ELECTRICAL DRAWINGS ARE DIAGRAMMATIC IN NATURE;THEREFORE, (2) JUNCTION BOX CF COMPACT FLUORESCENT THE ELECTRICAL CONTRACTOR SHALL COORDINATE ALL ELECTRICAL EQUIPMENT AND DEVICE LOCATIONS WITH ARCHITECTURAL,MECHANICAL, Allowed Exterior Lighting Power PAD MOUNT CKT CIRCUIT AND PLUMBING DIVISIONS PRIOR TO ROUGH-IN. REFER TO AND COORDINATE ui A B C D E TRANSFORMER CO CONDUIT ONLY, PROVIDE PULL-LINE WITH ARCHITECTURAL, MECHANICAL,AND PLUMBING DRAWINGS FOR CT CURRENT TRANSFORMER ADDITIONAL WORK THAT IS REQUIRED BY THE ELECTRICAL CONTRACTOR. Area/Surface Category Quantity Allowed Tradable Allowed Watts CTL CONTROL Watts/Unit Wattage (B X C) DC DIRECT CURRENT B. PROVIDE PULL-LINE IN ALL EMPTY CONDUITS. Parking(Parking area) 43650 ft2 0.06 Yes 2619 (D) DEMOLITION C. CONTRACTOR SHALL COORDINATE WITH AN UNDERGROUND LOCATING Total Tradable Watts(a)= 2619 DEMO DEMOLITION SERVICE PRIOR TO COMMENCING WORK. SEE CIVIL DRAWINGS FOR Total Allowed Watts= 2619 DET DETAIL ADDITIONAL SITE INFORMATION. COORDINATE WITH OTHER SITE DISCIPLINES. UJ Total Allowed Supplemental Watts(b)= 600 DTT DOUBLE TWIN TUBE (a)Wattage tradeoffs are only allowed between tradable areas/surfaces. CIRCUITING SYMBOLS E EMERGENCY D. SITE LIGHTING AND UTILITYEQUIPMENT SHOWN IN APPROXIMATE LOCATION. Q (b)A supplemental allowance equal to 600 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. (E) EXISTING COORDINATE EXACT LOCATION WITH CIVIL DRAWINGS,PROPERTY LINES,AND EC ELECTRICAL CONTRACTOR UTILITY COMPANIES PRIOR TO ROUGH-IN. Proposed Exterior Lighting Power EL EMERGENCY LIGHT A B C D E DESIGNATES CIRCUIT ON CURRENT CARRYING E. REFER TO POLE BASE DETAIL FOR SITE LIGHTING POLE BASE REQUIREMENTS. Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) EMERGENCY SOURCE CONDUCTORS F FUSE Fixture Fixtures Watt. (F) FUTURE F. ROUTE CONDUITS IN COMMON TRENCH WHERE POSSIBLE REFER TO UNMARKED CIRCUIT IS GONGEALED 1 NEUTRAL CONDUCTORS FACP FIRE ALARM CONTROL PANEL TRENCHING DETAIL. Parking( Parking area 43650 ft2):Tradable Wattage CEILING OR WALL. MAINTAIN G/GND GROUND O LED 1: PL1: DOUBLE HEAD POLE LIGHT:Other: 1 2 204 408 CONDUIT AND CONDUCTOR SIZE GROUNDING CONDUCTOR GFCI GROUND FAULT CIRCUIT INTERRUPTER CJ LED 2: PL2:SINGLE HEAD POLE LIGHT:Other: 1 1 102 102 THROUGHOUT ENTIRE CIRCUIT. GFI GROUND FAULT INTERRUPTER LED 3: PL3:SINGLE HEAD POLE LIGHT:Other: 1 1 102 102 Cz Total Tradable Proposed Watts= 612 HH HAND HOLE BEGINNING OF INDIVIDUAL PANEL NAME HID HIGH INTENSITY DISCHARGE T CIRCUIT NUMBER(S) HOA HAND-OFF-AUTO Exterior Lighting PASSES: INDICATED. CIRCUIT# HPS HIGH PRESSURE SODIUM ELECTRICAL SPECIFICATIONS W _ mime Design � better code INDICA Exterior Lighting Compliance Statement HVAC HEATING,VENTILATION,&AIR CONDITIONING Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans, V EM NIP A-2,4,6 specifications, and other calculations submitted with this permit application.The proposed exterior lighting systems have been 6 IG ISOLATED GROUND A. ALL WORK SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE designed to meet the 2015 IECC requirements in COMcheck Ve n 4.1.3.0 and to co ith any applicable mandatory IPCO IDAHO POWER COMPANY LOCALLY ADOPTED ELECTRICAL CODE,ALL LOCAL CODES,AND TO THE FULL requirements listed in the Inspection Checklist. ACCEPTANCE OF THE AUTHORITY HAVING JURISDICTION. Kurt Lechtenberg 10/30/20 CONDUIT DOWN �, CONDUIT UP PANEL HOMERUN.(3/4"-2#12,1#12G CONDUCTORS UNO) J-BOX JUNCTION BOX cc Name-Title Si a e Date 1"-4#10,1#10G KA KILOAMP B. OBTAIN ALL PERMITS,COORDINATE,FURNISH,INSTALL,CONNECT AND TEST O KVA KILO VOLT-AMP ALL ELECTRICAL EQUIPMENT REQUIRED FOR ALL THE SYSTEMS INSTALLED RACEWAY- SIZE KW KILOWATT UNDER THIS CONTRACT TO INSURE COMPLETE AND FULLY OPERATIONAL TITY y KWH KILOWATT HOUR SYSTEMS. CONCEALED IN EXISTING QUAN LCP LIGHTING CONTROL PANEL FLOOR OR NOTE: C. CONTRACTOR SHALL MAINTAIN A COMPLETE SET OF AS-BUILT DRAWINGS. C)UNDERGROUND MB MAIN BREAKER AS-BUILT SET OF DRAWINGS SHALL BE UPDATED DAILY AND SHALL DOCUMENT EDISON STYLE SHARED NEUTRAL CONDUCTORS ARE NOT ALLOWED. MBR MAIN CIRCUIT BREAKER THE ACTUAL INSTALLED CONDITION OF THE ENTIRE ELECTRICAL Q CONDUIT,STUBBED,CAPPED AND MARKED EACH 1 POLE BREAKER SHALL BE FURNISHED WITH AN INDIVIDUAL MCC MOTOR CONTROL CENTER INSTALLATION. AS-BUILT SET OF DRAWINGS SHALL BE AVAILABLE AT ALL MDP MAIN DISTRIBUTION PANEL TIMES ON THE SITE FOR INSPECTION BY CODE OFFICIALS,OWNER,ARCHITECT, DEDICATED NEUTRAL CONDUCTOR. Project Title: Eagle Commons at Ustick and Eagle Report date: 08/07/20 WITH PULL CORD AS SPECIFIED MLO MAIN LUGS ONLY Data filename: P:\Files\2019\19359\CALLS\ELEC\19359 Elec_Compliance.cck MMC MODULAR METERING CENTER AND ENGINEER. 0 MH METAL HALIDE = Q MSB MAIN SWITCH BOARD D. PROTECT ALL EXISTING WORK FROM DAMAGE DURING CONSTRUCTION. O MTG MOUNTING O NOTE: THIS IS A STANDARD LIST OF COMMONLY USED ELECTRICAL SYMBOLS. SOME N NEUTRAL E. COORDINATE ALL ELECTRICAL WORK WITH ALL OTHER TRADES. Y OF THE SYMBOLS SHOWN MAY NOT HAVE BEEN USED IN THIS DRAWING (N) NEW C O C..) PACKAGE. NC NORMALLY CLOSED F. ALL MATERIALS AND EQUIPMENT FURNISHED TO THE PROJECT SHALL BE NEW NEC NATIONAL ELECTRICAL CODE AND SHALL BEAR THE LISTING LABEL OF A NATIONALLY RECOGNIZED TESTING Roo U) NIC NOT IN CONTRACT LAB AS DEFINED BY OSHA. W NL NIGHT LIGHT CA -0 NO NORMALLY OPEN G. ALL ELECTRICAL DEVICES AND TERMINALS SHALL BE RATED 75°C MINIMUM. '0 U) NTS NOT TO SCALE < q H. ALL CONDUCTORS SHALL BE STRANDED COPPER,600 VOLT RATED. cc W .Co OH OVERHEAD INSULATION TYPE SHALL BE THHN/THWN,FULLY COLOR CODED WITH GAUGE, 44 _0 OS OCCUPANCY SENSOR U7 TYPE AND MANUFACTURER MARKED EVERY 24"ALONG. CONDUCTOR COLOR O 19-359 P POLES CODE SHALL BE AS FOLLOWS: UJ coLIGHTING FIXTURE SCHEDULE ) PC PHOTO-CONTROL 120/240 VOLT SYSTEM PVC POLYVINYL CHLORIDE PHASE A -BLACK 1 TYPE DESCRIPTION MTG. LAMPS WATTS MFG. & CATALOG NUMBER OR EQUAL BY NOTES PWR POWER PHASE B -RED Revisions EXTERIOR POLE WITH (2) LED FIXTURES POLE LED LITHONIA NO. McGRAW-EDISON NEUTRAL -WHITE PL1 FORWARD THROW DISTRIBUTION MOUNTED 4000K 204W DSX1 LED-P3-40K-TFTM-MVOLT-SPA-DDBXD 1 RE: REFERENCE GROUND -GREEN 1' 25-FOOT POLE +25'-0" 24,620 LUMEN EA. POLE: SSS-25-4C-DM28AS-DDBXD REC RECEPTACLE (R) RELOCATED I. MINIMUM SIZE WIRE FOR CIRCUITS SHALL BE#6 AWG. ALL CONDUCTORS EXTERIOR POLE WITH (1) LED FIXTURE POLE LED LITHONIA NO. McGRAW-EDISON SHALL BE ROUTED IN 1"CONDUIT MINIMUM. PL2 FORWARD THROW DISTRIBUTION MOUNTED 4000K 102W DSX1 LED-P3-40K-TFTM-MVOLT-SPA-DDBXD 1 SF SQUARE FEET 25-FOOT POLE +25'-0" 24,620 LUMEN POLE: SSS-25-4C-DM28AS-DDBXD J. MAKE ALL CONNECTIONS TO EQUIPMENT PER MANUFACTURER'S EXTERIOR POLE WITH (1) LED FIXTURE POLE LED LITHONIA NO. McGRAW-EDISON TBD TO BE DETERMINED REQUIREMENTS. TDR TIME DELAY RELAY PL3 TYPE 3 DISTRIBUTION MOUNTED 4000K 102W DSX1 LED-P3-40K-T3M-MVOLT-SPA-DDBXD 1 TK TOE KICK K. ALL CONDUCTORS IN ELECTRICAL PANELS,CABINETS AND EQUIPMENT SHALL 25-FOOT POLE +25'-0" 24,620 LUMEN POLE: SSS-25-4C-DM28AS-DDBXD TSP TWISTED SHIELDED PAIR BE NEATLY TRAINED AND LACED. CITY OF MERIDIAN TYPE 1 STREET POLE PER CITY OF EATON/STREETWORKS NO. AMERICAN ELECTRIC TRT TRIPLE TUBE PS1 LIGHTING FIXTURE WITH DAVIT TYPE POLE MOUNTED MERIDIAN 95W USSL-A02-D-U-T2-MA-BK-4N7-TH PHILLIPS 2 TTB TELEPHONE TERMINAL BOARD L. THE CONTRACTOR SHALL PROVIDE UPDATED CIRCUIT PANEL DIRECTORIES SEMI-GLOSS BLACK FINISH STANDARDS POLE: VALMONT OR KW DAVIT POLE (TYP.) TYPICAL FOR ALL PANELS. DIRECTORIES SHALL BE TYPED. CITY OF MERIDIAN HISTORIC STREET POLE PER CITY OF HOLOPHANE NO. UC UNDERCABINET M. PROVIDE ELECTRICAL SUBMITTALS FOR EQUIPMENT SHOWN AS REQUIRED BY PS3 LIGHTING POLE AND FIXTURE WITH BANNER MOUNTED MERIDIAN 70W FIXTURE: ARU-70-4K-AS-G3-B-S 2,3 UG UNDERGROUND DIVISION 1 SPECIFICATIONS. ARMS & RECEPTACLE. BLACK FINISH, STANDARDS POLE: CP12F5/18-CA/BK U.N.O. UNLESS NOTED OTHERWISE LIGHTING FIXTURE SCHEDULE NOTES: V VOLT N. ELECTRICAL CONTRACTOR SHALL OBTAIN THE AVAILABLE FAULT CURRENT 1 SUBSTITUTIONS WILL BE ALLOWED IF SUBMITTED PRIOR TO BID DATE BY THE GREATER OF: 7 BUSINESS DAYS OR THE TIME PERIOD SPECIFIED BY VA VOLT-AMPERE VALUE FROM THE LOCAL UTILITY OR THE ONE-LINE DIAGRAM AND LABEL THE DIVISION 1 SPECIFICATIONS, AND IF DEEMED EQUAL BY THE ENGINEER. THE CONTRACTOR IS RESPONSIBLE FOR ENSURING SUBSTITUTED FIXTURES W WATT MAIN BREAKER WITH THAT VALUE. MEET OR EXCEED THE SPECIFICATIONS OF THE FIXTURES SPECIFIED. WG WIRE GUARD 2 PROVIDE ALL MATERIALS REQUIRED PER CITY OF MERIDIAN STANDARDS. WP WEATHER PROOF/NEMA 3R 3 SUBSTITUTIONS WILL BE ALLOWED IF PRIOR APPROVAL IS PROVIDED BY THE CITY OF MERIDIAN. PROVIDED/ PROVIDE AND INSTALL/PROVIDED AND PROVIDE BY INSTALLED BY/PROVIDE AND INSTALL INSTALLED/ INSTALL FIXTURE SCHEDULE NOTE: THIS IS A STANDARD LIST OF COMMONLY USED ELECTRICAL ABBREVIATIONS. SOME OF THE ABBREVIATIONS SHOWN ABOVE MAY NOT BE USED IN THIS DRAWING PACKAGE. Project No.: 119025 Date of Issuance: 01/22/2021 Project Milestone: Permit Set Electrical Cover Sheet EOmOO MUSGROVE %'�� THE ENGINEERING,P.A. �� ��� 234 S.Whisperwood Way .� LAND Boise,Idaho 83709 . 208.384.0585 www.musgrovepa.com � GROUP OVER 40 YEARS OF EXCELLENCE Proi-No. 19-359 -G G G G\G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G- G KEYED NOTES : O# SYMBOL USED FOR NOTE CALLOUT. 111812021 I / 1. ROUTE CIRCUIT SITE LIGHTING METER PEDESTAL. PROVIDE 1"CONDUIT E. UStick Road - WITH 2#6, 1#6G.TERMINATE CIRCUIT ON AVAILABLE 2-POLE BREAKER IN =cn - ==_ - - -3� - - o--- � -�� �� �� _ _��--���- �- - �� \° THE METER PEDESTAL LOAD CENTER.PROVIDE PULLBOXES AS REQUIRED TO ACCOMMODATE THE CIRCUIT LENGTH.CIRCUIT TO BE CONTROLLED BY THE METER PEDESTAL PHOTOCELL.RE:E2.00 I 2. PROVIDE A JUNCTION BOX FOR FUTURE SIGN.THE JUNCTION BOX LID SHALL BE LABELED"POWER"OR"ELECTRICAL".JUNCTION BOX SHALL BE LOCATED WITHIN 3-FEET OF THE FUTURE SIGN LOCATION. ----=—_—_—_ _----��--- n O 3. 1"CONDUIT WITH PULL-LINE FROM PULLBOX TO PARKING LOT LIGHTING OHP$"- -oaa"" - -orm°g° - - H °RP��oHP o nay _ METER PEDESTAL.PROVIDE PULLBOXES AS REQUIRED TO W --- -----uap-- ——— UGP----UGP-- GP-----U --- OHP OHP --- OHP RQN - " -$'"� ACCOMMODATE THE CONDUIT LENGTH.THE DISTANCE BETWEEN IJGP__-___ asp uGso" oHP o"� " —RML _ _ PULLBOXES SHALL NOT EXCEED 300 FEET. ------------------------------------- U P UGO"N.� H2—— �———$ML Rnru �M' — —nnru — BnN mow- RnN — RMI_ _ RftN RMI — - _p� -- — — — -- — ------------------------ --------- ---------------------- UGP UGPP — — UGP"P U�HP �G�Y1� ��nuo��nHPUGP OHPUGP OHP \ OH OHP OHP OHP�OHP- 4. 120/240 VOLT,SINGLE-PHASE UTILITY TRANSFORMER PROVIDE BY IDAHO �Rnv RM Rnv FVW Rnv �1Jgp POWER COMPANY. Up 2 \ 5. UNDERGROUND SECONDARY BY IDAHO POWER COMPANY. ax R/WG AND SIGNAGE. THE UJ 7T71� Fvw 6. METER PEDESTAL CABNET SHALL BE AO 00AMPN 20/0240-VOTINSI GE-PHASE SERVICE ENTRANCE RATED METER PEDESTAL WITH INTEGRAL LOAD CENTER AND PHOTOCELLL.THE LOAD CENTER SHALL BE A 12-CIRCUIT UNIT WITH I 100-AMP RATED MAIN BREAKER. RE:E2.00.�' Q CL \ FUTURE DEVELOPMENT PAD FUTURE DEVELOPMENT PAD O FUTURE DEVELOPMENT PAD --------------------------------------------------------------------------- o, \ I C4 � EP EP EP EP EP EP EP GI EP EP R 36"GIRR 36"GIRR 36"GIRR 36"GIRR � I EP EP EP EP LO EP EP EP—EP 4, 3 IEEE—EP— \ $ EP�EP�EP�EP EPcc cc EP EP EP w I EP EP I I O - - - I I Cp y P EG I I = co I \ —— -- -- ------ -- — PL -- -- ---- - - ------ -- -- -- I cc � Q \ W O �� O EP � O �J Fp\ \\ � w 3 � O Fp `\ Roo \ 2 W y � � ` 4 L3 O I Q c I I W .� 6 I I o a) W co - FL L FL FL \ \ \ W \ FUTURE DEVELOPMENT PAD i I G I G G G G G EP - 1 Revisions ---- I I I I =xJ-x__ X I I FUTURE DEVELOPMENT PAD FL _X� x� I I FL FL — — — �R \ — — — FLU — x�X— L \ — — F� FL AFL AFL— X—X— X� I X�X—X� FL--FE �X—X n I FL�FL AFL—F� x X_X_ \ I — — — -- — — —\FL—FLU\ — — — — X—X=x — R X_ GIRR RR- ',; 36"GIRR 36"GIR 3"GIRR 36"GIRR 3 RR —I I FL EL FL — — X X X X� \ 36"GIRR 36"GIR — — — — FL — — — — — x ,✓ 'GIRR 36"GIRR 36"GIRR — 36„ERR— FL FL pL — — — — — I — 36"GIRR — 36'GIRR I Fp OHP—OHP 1 I \ OHP—OHP I �OHP i I I I I I I tiq I I I 041 I I I _ I I UGP I UGP UGP�— ------------------------------- ----o--e---------- --- ---------------------______ ProjectNo.: 119025 Date of Issuance: 01/22/2021 \ I Project Milestone: Permit Set I I I Electrical Site Plan - Electrical Site Plan - Parkin g g g Lot Li htin o 20' 40' Parking Lot Lighting Horizontal Scale: 1" = 20' El O O MUSGROVE %'�� THE ENGINEERING,P.A. �� ��� 234 S.Whisperwood Way .� LAND Boise,Idaho 83709 . 208.384.0585 www.musgrovepa.com � GROUP OVER 40 YEARS OF EXCELLENCE Proi-No. 19-359 -G G G G�G G G G G G G G G G G G G G G G G G G G �G G G G G G G G G G G G G G KEYED NOTES : G G G G G G G G G G G G G G G G G G G G G G G G G- G - T # SYMBOL USED FOR NOTE CALLOUT. 111812021 I O $ 1. TYPE 1 STREET LIGHT WITH DAVIT POLE. INSTALL POLE AND FIXTURE PER _ — �■ �S�'C■ �oa - ISPWC STANDARDS AND CITY OF MERIDIAN SUPPLEMENTAL —.q An — — —3fi — - �-- � -�� K p �� --�� _ _��--���0— �— - �� ° SPECIFICATIONS.REFER TO SHEETS E2.00&E2.10 FOR ADDITIONAL I INFORMATION. 2. HISTORIC TYPE STREET LIGHT AND POLE.POLE TO INCLUDE BANNER I ARMS AND GFCl/WP RECEPTACLE.INSTALL POLE AND FIXTURE PER ISPWC STANDARDS AND CITY OF MERIDIAN SUPPLEMENTAL SPECIFICATIONS.REFER TO SHEETS E2.00&E2.01 FOR ADDITIONAL --- - INFORMATION. I - - - - - - PS1 1 � I -aHP— - BHP - - _9FP_ - - - -OHP---OHP OHP OHP _ _ _ 8 3. PROVIDE IN-GRADE JUNCTION BOX WITHIN 3-FEET OF THE POLE BASE W GP _—�JGR --- - � --� ---aHP---------- _ 8 O PER ISPWC STANDARDS AND CITY OF MERIDIAN SUPPLEMENTAL - --- _ HP — — — psi OGP UGP �� UGfo ON UGF OHP�-af--OHP�Hy!-1 8 SPECIFICATIONS THE JUNCTION BOX LID SHALL BE LABELED -- _ - ___ ------ ------ _ -- use"�� "e __-- - - - _ - - - - - - _ - LIGHTING". REFER TO SHEETS E2.00&E2 10 ------------------------ — — — UGP GBN UGBH Uur —�GW+� UGPnuPUG� UGP UGP ____--___ bNP "ELECTRICAL"OR"STREET --- — — — — — — _ -- ---- � P ..qHp OHP OHP OHP ON OHP OHP OHP OHP— __ __ ------� 3 -------- --- � 7 FOR ADDITIONAL INFORMATION. CZ 0 6 6 4 371 u P\ `�' 4. 1"CONDUIT WITH 3#6 AND 1#6 GROUND THWN,COPPER CONDUCTORS a ` PER ISPWC STANDARDS AND CITY OF MERIDIAN SUPPLEMENTAL ` SPECIFICATIONS. UJ � I — — 5. APPROXIMATE LOCATION OF EXISTING 1"CONDUIT STUBBED FROM Q EXISTING HISTORIC TYPE STREET LIGHTING JUNCTION BOX.COORDINATE L j WITH EXISTING CONDITIONS PRIOR TO BEGINNING WORK.EXTEND 1" j CONDUIT TO NEW STREET LIGHTING JUNCTION AND INSTALL 3#6 AND 1#6 7 �II I I GROUND THWN,COPPER CONDUCTORS PER ISPWC STANDARDS AND i CITY OF MERIDIAN SUPPLEMENTAL SPECIFICATIONS. 6. APPROXIMATE LOCATION OF EXISTING 1"CONDUIT STUBBED FROM EXISTING TYPE 1 STREET LIGHTING JUNCTION BOX.COORDINATE WITH O ------------____ i EXISTING CONDITIONS PRIOR TO BEGINNING WORK.EXTEND 1"CONDUIT ------------------------------------------------------ I TO NEW STREET LIGHTING JUNCTION AND INSTALL 3#6 AND 1#6 GROUND THWN,COPPER CONDUCTORS PER ISPWC STANDARDS AND CITY OF 3 P 2 I MERIDIAN SUPPLEMENTAL SPECIFICATIONS. 7. APPROXIMATE LOCATION OF EXISTING STREET LIGHTING FIXTURE y EP—EP—EP—EP—EP P EP EPEP EP —EP—EP I I MOUNTED ON TRAFFIC SIGNAL POLE. GI II I R 36"GIRR 36"GIRR 36"GIRR EP EP EP EP 4 i I I LO 8. APPROXIMATE LOCATION OF EXISTING UTILITY POWER POLE WITH 36"GIRR EP Fp EP Ep— I I M OVER-HEAD UTILITY LINES. II P�EP�EP�EP�EP EP EP EP EP C>I cc EP�EP I I EP EP Up C4 nn n _ _ I I I I I _ �GI — _ — I �I c O I I I I II I p _ I 0 3 I 2 itI cc Q I W O EP I I Z \EP W Roo � I y � Q Co c i I I c W Cco FL I I III I I FL L FL L—EP I I I I TG I G G G G G- 1 \ � � 2 I Revisions I i IP / _x—I—X_ I I 3 ► I FL X _X� — — x�x� FL FL FL — —x—X X — — — — x — — F FL— \ — — F� FL AFL�EL� X—X— X� X—X -:—x ��FL=F� — — R — X x�X �FL� I \ _ _ FL F F x x x X� L�FL� — — — — — X�x— I / GIRR — — — FL— _ — — _ — — _ —X , 36"GIRR 36"GIR 3"GIRR — I — — — FL FL __ — X----I-x / IRR- — — — — FL X------ l \ 36"GIRR 3 RR —I — — FL — I —x_X_ 36"GIRR — _ `1✓ 36"GIR 'GIRR 36"GIRR 36"GIRR — — 36"61RR_ FL—FL pL -I- — I — 36"GIRR — 36"GIRR I ow FP — I / ONP—OHP I / 1 � OHp I I I I I UGP I UGP UGP�— i -- ----------------- -- ' I — — — J --------------- ____ I Project No.: 119025 \ I I Date of Issuance: 01/22/2021 \ I I Project Milestone: Permit Set nnnI Electrical Site Plan - Electrical Site Plan - Street L�g g htin 0 20' 40' Street Lighting Horizontal Scale: 1" = 20' ElmlO MUSGROVE N; OML TH E ENGINEERING,P.A. "S 234 S.Boise,Ida o 837 Way .� LAN D NUMBER OF FIXTURE HEADS VARY WITH 0 Idaho 83709 . 208.384.0585 TYPE OF FIXTURE SEE FIXTURE SCHEDULE _ G RO U P www.musgrovepa.com OVER 40 YEARS OF EXCELLENCE Project No. 19-359 POLE PER SCHEDULE 1 1013012020� HANDHOLE WITH CONCEALED WELDED STEEL TENON WITH STAINLESS GROUNDING LUG STEEL BOLTS(ALL WITH POLE) RUBBED BASE TO 12"BELOW BASE COVER TO MATCH POLE WITH STAINLESS SCREWS GRADE. RUB CORNERS ROUND AND SIDES SMOOTH 120/240 V,3-WIRE NON-SHRINK GROUT UNDER BASE PLATE PACKED TIGHT SERVICE BY IPCO AFTER LEVELING METER PEDESTAL I I I 30"MIN. LANDSCAPED ' WHERE UJ SURFACE FINAL GRADE o CY) APPLICABLE CURB I MAIN 00 o 0 o SERVICE LUGS TEST BYPASS FACILITY HOOPS RODS POLE TYPE X Y D E W N METER SOCKET NO. SIZE LIN. FT NO. SIZE LIN. FT #4 ARE COPPER BOND FROM BOLT TO REBAR WITH EXOTHERMIC WELDOR m TYPE 1 -30' 24" 60" 10%2" 11" 11%2" 4 #4 21' 6 #4 36' W - COMPRESSION FITTING TYPE 1 -35' 30" 84" 10%2" 11" 11%2" 6 #4 41' 6 #6 39' SCHEDULE 40PVC 1 TYPE 2 24" 60" 8 9 8" 4 #4 21' 6 #4 27' " ( ) LENGTH OF ANCHOR BOLTS PER MANUFACTURERS PHOTOELECTRIC z_ TO HANDHOLE OR NEXT RECOMMENDATIONS. INSTALL PER FACTORY TEMPLATE. LIGHTING CONTROL HISTORICAL 24" 60" 12" 13" N/A 4 #4 21' 6 #4 27' FIXTURE AS SHOWN. _ DOUBLE LUGS WITH FLAT WASHERS AT BASE PLATE. CONTROL DAVIT 24" 72" 10%" 11" 11%z" 5 #4 31'4" 8 #5 44'N CLEAN BOLT THREADS AND SURFACES TO PROVIDE CIRCUIT CONTRACTOR ANCHOR BOLT SIZES AND LOCATION GROUNDING CONTINUITY TO POLE. MAIN BREAKER 120-V (TYPICAL) PER MANUFACTURERS 100-A,240-V AUTO SPECIFICATIONS O GALV. #4 REBAR CAGE AT 6"O.C.EACH WAY TOP TO BOTTOM. CONDUIT LEVELING INSTALL(3)#4 HORIZONTAL TIES WITHIN TOP 6"OF BASE TEST N Lw III Tr HEIGHT4" NUT F— -- ---- ----- PARKING LOT 1"MAX.GAP, CONTRACTOR MAY USE PRE CAST POLE BASE. h— ------- ----- DO NOT GROUT �. LIGHTING SUBMIT PRE-CAST DRAWING TO ENGINEER 24"ROUND FORMED FOR APPROVAL. LIGHTING&SIGN SEE SCHEDULE S AND TYPE 2 AND HISTORICAL CIRCUIT BREAKERS N VOERTIOCOALBARS POLE BASE DETAIL CA (2-POLE) F— ------- ----- SPARE RIGIDPLAS F— ------- ----- CONDUIT = a N o Y4 1oY HANDHOLE REINFORCED WITH uW) y2'NC NO.3 GAUGE RING F_ _ FUTURE SITE 3"CLEARANCE a m GROUND NUT FOR OF P WIDE WELD F OUTSIDE h— ------- ----- SIGN GROUND OF POLE COVER OF 11 GAUGE IRRIGATION PLATE NEC APPROVED O CONTROLLER GROUNDING CIRCUIT BREAKER CONNECTOR GALV.HOLD DOWN N NUT&WASHER SINGLE POLE F_ _______ _____ FUTURE SITE 2 MIN.TO 4 MAX. SITE LIGHTING POLE BASE DETAIL I — ------- ----- SIGN cc 3"CLEARANCE THREADS O NITS _ I ' _ 2"MAX.GAPS N BASE WIDTH"X" DO NOT GROUT SPARE GALVANIZED 4 Q LEVEL NUT AND WASHER TYPE 1 AND DAVIT POLE 0 BASE DETAIL Q N p SPARE „W„ GENERAL NOTES: O 1. CONCRETE FOR FOUNDATIONS SHALL HAVE A MINIMUM 28-DAY COMPRESSIVE O Y STRENGTH OF 3,000 PSI. CJ U 2. ALL REBAR REINFORCEMENT SHALL HAVE 3"CLEARANCE FROM OUTSIDE OF — CONCRETE FOUNDATION. O IRRIGATION 3. HOOP SHALL HAVE A 6"LAP LENGTH MINIMUM ? _r_ CONTROLLER "D" � (a 4. BREAKAWAY BOLTS ARE REQUIRED WHEN ON STATE HIGHWAYS,SEE ITD UJ STANDARD DRAWING I-7-C. PATCH TO MATCH BOLT DIA.+%4' 5. TYPE 1,TYPE 2 AND DAVIT POLE TO BE PROVIDED WITH METAL,2-PIECE BASE q ASPHALT, EXISTING FINISH COVER TO MATCH POLE FINISH w M CONCRETE, BASEPLATE AND BOLT 6. ALL CONDUIT ELBOWS USED IN CONCRETE BASES SHALL BE RPC _0 CONDITIONS DETAIL GENERAL NOTES: MAIN BONDING IJ7 LAWN,ETC PATTERN DETAIL COMPACTED FILL IN 6"LIFTS FINISHED GRADE JUMPER 7. STEEL CONDUIT SHALL BE USED TO EXTEND ELBOWS BEYOND FOUNDATION � 00 OR PER SPECIFICATIONS 1. AUTO TEST SWITCH SHALL BE 120-V RATED. 8. SPARE STUBOUTS SHALL BE TERMINATED WITH A STEEL COUPLING AND PLASTIC C PUSH PLUG AT BOTH ENDS 2. PHOTOELECTRIC CONTROL UNIT SHALL BE GROUNDING BUSS SECURED INCLUDED WITH THE PHOTOCELL,A SEPARATE TO THE SERVICE EQUIPMENT 1 1 / / 12" CONTACTOR AND A TEST SWITCH. REVISED�uLzo,s Revisions ITY OF GROUNDING C SUPPLEMENTAL DETAILS FOR ELECTRODE MERIDIAN STANDARD DRAWING NO. 1 3. NEUTRAL LUG AND NEUTRAL BUSS SHALL BE ADDITIONAL SPECIFICATIONS T2 6"RED MARKER TAPE, INSULATED FROM THE SERVICE EQUIPMENT GROUNDING TO THE IDAHO STANDARDS FOR STREET LIGHT BASE INSTALLATION RUN LENGTH OF TRENCH----';- O2 ENCLOSURE. IN FOUNDATION ELECTRODE PUBLIC WORKS CONSTRUCTION 4. THE LANDING LUG SHALL BE SUITABLE FOR MULTIPLE CONDUCTORS. 5. 2-POLE BREAKES SHALL BE GANG OPERATED. CONDUITS O 6. PRESSURE TYPE TERMINALS SHALL BE SUPPLIED O SAND BEDDING AND BACKFILL BY AFTER CONTRACTS. CONTRACTOR DETAIL NOTES: SITE LIGHTING METER BASE DETAIL # SYMBOL USED FOR NOTE CALLOUT. NTS 1. IF MULTIPLE CONDUITS SHARE TRENCH, PROVIDE SPACING BETWEEN CONDUITS. PROVIDE ZIP TIES,AND TIE ALL CONDUITS TOGETHER TO ENSURE STABILITY. 2. BURIAL DEPTH TO BE VERIFIED WITH UTILITIES AND AUTHORITY HAVING JURISDICTION: ELECTRICAL FEEDERS, COMMUNICATIONS: 24" MINIMUM UNDERGROUND SECONDARY: 30"MINIMUM UNDERGROUND PRIMARY: 42" MINIMUM SITE TRENCHING DETAIL Project No.: 119025 NTS Date of Issuance: 01/22/2021 Project Milestone: Permit Set Electrical Details E100 MUSGROVE �\ /���' ENGINEERING,P.A. ����' THE 234 S.Whidaho 8 7 Way .� LAND 3"x 3" HIGH TENON Boise,Idaho 83709 . 208.384.0585 www.musgrovepa.com � GROUP OVER 40 YEARS OF EXCELLENCE MINIMUM ALLOWABLE WIRE SIZES(AWG)' READING WINDOW, 16 38" DIA. Project No. 19-359 TYPE 1 COBRAHEAD TYPE 2-SHOEBOX HISTORICAL 316"THICK UV (ACROSS VOLTAGE AWG(MIN) VOLTAGE AWG(MIN) VOLTAGE AWG(MIN) FRESISTANCE LEXAN --1 ° ° 1— s 120 4 120 6 120 10 1 f =_— THE FLATS) 208 8 208 NOT ALLOWED 208 10 I NAMEPLATE 240 10 240 NOT ALLOWED 240 10 jj I CONTINUOUS FUSED "IN—LINE" TYPE WIRE CONNECTOR —_—' TEST BYPASS I T MODEL SEC 1791—SF OR APPROVED EQUAL 277 NOT ALLOWED 277 NOT ALLOWED 277 NOT ALLOWED L FACILITY jj I II I I I PIANO HINGE 480 NOTALLOWED 480 NOT ALLOWED 480 NOT ALLOWED —J — Lj METER SOCKET *MAX.RUN LENGTH-2500' 'MAX.RUN LENGTH-1500' "MAX.RUN LENGTH-1000' NEUTRAL LUG CONTINUOUS I RUN LENGTHS FROM SERVICE POINT TO FARTHEST STREET LIGHT BEING SERVED BY IT 11 I THE SYSTEM SHALL NOT EXCEED SPECIFIED DISTANCE PIANO HINGE `I' r `/ �J PHOTOCONTROL ., 101301W FOR EXTERIOR F———— PADLOCK HASP I WINDOW COVER�� I j DOOR AND TEST SWITCH LANDING LUGS LATCH A DEAD FRONTPANEL MOUNTING PANEL NEC APPROVED CONNECTOR b PADLOCK HASP UTILITY AREA FOR NEUTRAL WIRE,IF USED - 1 LATCH LOAD SIDE HINGED NEC APPROVED GROUNDING/BONDING HANDHOLE CONNECTOR ,� LI MAIN BONDING � LI PULL AREA DOOR JUMPER BALLAST 1/2"x6"P.V.C.CONDUIT ✓ NEUTRAL BUS I 5„ HOUSING INSTALL SLEEVE-FILL TOP 2"WITH 10 AWG.MIN.WIRE SIZE i —I 3 SILICONE GROUT I I I SERVICE FROM FUSE CONNECTOR I II GROUND BUS 1^ II CABINET To FIXTURE y1 I YI II SET SCREWS SEE MIN.ALLOWABLE I I I I FOR TYPE 1 J-BOX REQUIRED WITHIN 3 FEET I WIRE SIZES TABLE �i LI BONDING JUMPER (� LI AND OF ANY POLE WHEN DISTANCE HISTORICAL TO CABINET OR FUSED J-BOX IS STREET 50 FEET OR GREATER — GROUND CLAMP FIXTURE LIGHTS 2 2 FINISHED CONDUIT HEIGHT a' GALV.ANCHOR GRADE BOLTS,%"x 18" INSTALL .•°., _ FT' POWER FUSED JUNCTION . .?' •d:... w —II —I II I —� —ICOMPANY _ BOX dSERVICE 3, J BT1O'PE PR . .. LOAD �_� IJ I-1 L- POINT MAX STREET � e iVLIGHTS �; '., CONDUIT II SERVICE �—-� n 1. a' '• ' GROUNDING CONDUIT �l 4. ELECTRODE 7Y4" Q SERVICE LOAD CONDUIT CONDUIT 10" DIA. OPENING '. 2"MIN.SCH.40 1"MIN.SCH.40 2 r. ' PVC CONDUIT PVC CONDUIT '.�� • , •j' FRONT VIEW SIDE VIEW CONDUIT/WIRING p '•i'�':�� FOR THE NEXT (DOWNSTREAM) STREET LIGHT IN ,•: ',a• THE SYSTEM '� • F" 5"X 7"X 3" H :": GROUND ROD(Per NEC ,ti •: ' SERVICE DOOR OPENING ��'..� •. •.: O Article 250-Grounding •.e.: . ENTRANCE 01 ANCHORAGE & �; DOOR 'i:•. N Bonding Per NEC Article GROUND USE •' •'e GENERAL NOTES: o o WIRING ACCESS OPENING 30-Service) #10CUMIN. CJ (2 PER POST) 1. MASTER-KEYED PADLOCKS SHALL BE GROUNDING ° SUPPLIED WITH CABINETS,CONTACT ___ ELECTRODE NEC APPROVED .•.,4.�+ ', . + LOCATION '•'1.::''� CITY FOR PADLOCK TYPE. a® GROUNDING .a '� •!' �' md:. CONNECTOR 2. AN ADDITIONAL GROUNDING ELECTRODE SHALL BE DRIVEN 6'FROM Q p y CABINET AND WIRED TO GROUND BUS. LOAD CONDUIT 13" DIA. ENTRANCES LEGEND ADDITIONAL ELECTRODE SHALL BE SOLI CIRCLE HOUSED IN A JUNCTION BOX. V-2" 1O EACH PHASE CONDUCTOR SHALL BE FUSED AT EVERY POLE AND SERVICE JUNCTION BOX BY MEANS OF 3. NO SHRUBS OR TREES SHALL BE BOLT PATTERN IN-LINE CONNECTORS.USE ONLY FAST ACTING FUSES RATED 100K RMS AMPS,600 VAC O2 WHEN A SPLICE IS REQUIRED USE SEC MODEL 0791-0 SPLICE KIT,POLARIS SSB 2/0,OR APPROVED EQUAL PLANTED WITHIN 1 O'OF CABINET. BASE FOR SERVICE CABINET I 18V DIA. AN 18"MINIMUM SLACK LOOP IS REQUIRED IN ALL JUNCTION BOXES O3 IF DISTANCE FROM POWER COMPANY SERVICE POINT TO SERVICE CABINET IS GREATER THAN 10 FEET,A a FUSED J-BOX SHALL BE INSTALLED WITHIN 10 FEET OF POWER COMPANY SERVICE POINT.DISTANCE FROM O POWER COMPANY SERVICE POINT TO SERVICE CABINET SHALL NOT EXCEED 150 FEET. REVISED 2013 REVISED 2013 CITY OF MERIDIAN STANDARD DRAWING NO. CITY OF MERIDIAN STANDARD DRAWING NO. CAI REVISED 2013 SUPPLEMENTAL STREET LIGHTING SUPPLEMENTAL HISTORICAL STREET LIGHT Z CITY OF MERIDIAN STANDARD DRAWING NO. SPECIFICATIONS SPECIFICATIONS SUPPLEMENTAL ONS WIRING REQUIREMENTS FOR TO THE IDAHO STANDARDS FOR SERVICE CABINET 5 TO THE IDAHO STANDARDS FOR POLE DETAIL 7 T PUBLIC WORKS CONSTRUCTION V PUBLIC WORKS CONSTRUCTION O TO THEIDA 1SPEC10E STTANDIAARDS FOR STREET LIGHT INSTALLATIONS 3 PUBLIC WORKS CONSTRUCTION = a 13'-3" O HOR. DIM. 120/240 V,3-WIRE O 12" STRAIGHT & BY IDAHO POWER HORIZONTAL Y 2 3/8" I O.D. X III 0 U NEUTRAL LUG I I I LANDING LUG O 8" R. LU y 0 METER SOCKET Q Co N AND SUPPORT 3' MIN. BACK OF SIDEWALK w Co WITHIN RIGHT-OF-WAY cc IDa L cc)TEST BYPASS W FACILITY SIDEWALK SIDEWALK O co G CURB & GUTTER CURB & GUTTER PHOTOELECTRIC LIGHTING CONTROL, CONTROL Revisions 15 A, 120 V ARM SHAFT N �. z iv a MAIN BREAKER, 5 8" D. x N 100 A,240 V GUIDE PIN w TO TEST N POINT "X" � _� LIGHTING CIRCUIT #1,240 V POLE SHAFT o* ASSEMBLED POINT "X„ LIGHTING CIRCUITS, 30 A,240 V-EACH SECTION N s 11/16" x 12 5/16" n l­- LIGHTING CIRCUIT HYDRANT ALIGNMENT SLOT - #2,240 V SIDEWALK HYDRANT .. NOTE: CURB&GUTTER SIDEWALK cuRe & GUTTER SLOT AND GUIDE PIN SHALL BE POSITIONED ON THE TOP N SIDE OF THE POLE AND ARM. � � •• LIGHTING CIRCUIT USL � �IP JOINT MAST � - #3,240V UARM ATTACHMENT 6Y2" 5' MIN 0 26Y2 R. N 5' MIN GENERAL NOTES: GENERAL NOTES: _ #4 2) TING VCIRCUIT .. THICKNESS OF FILLER RING(IF NEEDED)TO 1. MATERIALS AND 1. AUTO TEST SWITCH SHALL BE 15 A, 120 V MATCH DIFFERENCE IN TAPERED TUBE CONSTRUCTION SHALL THICKNESS x 1 1/2"WIDE 2. PHOTOELECTRIC CONTROL UNIT SHALL 10' MIN CONFORM TO AASHTO 2' MIN STANDARD SPECIFICATIONS INCLUDE PHOTOCONTROL,A SEPARATOR MAIN BONDING .135•THK.(10 GAUGE)x 3" FOR STRUCTURAL o CONTACTOR,AND A TEST SWITCH M WIDE BACK-UP RING SUPPORTS FOR HIGHWAY , m m 3. NEUTRAL LUG AND NEUTRAL BUS SHALL JUMPER � SIGNS,LUMINAIRES,AND ° o o w BE INSULATED FROM THE SERVICE GROUNDING BUS NOTES: / G TRAFFIC SIGNALS,5TH EQUIPMENT ENCLOSURE SECURED TO SERVICE O EDITION aEQUIPMENT 1. ALL BUTT WELDS TO BE GROUND ENCLOSURE 4. THE LANDING LUG SHALL BE SUITABLE NB OSURE FLUSH 2. POLE SHAFT SHALL = FOR MULTIPLE CONDUCTORS GB WATER METER 2. LONGITUDINAL:BUTT WELD BY CONFORM TO ASTM A572 THE SUBMERGED ARC PROCESS 5. 2-POLE BREAKERS SHALL BE GANG GRADE 50,55,60,OR 65 STREET TREE 3. CIRCUMFERENTIAL:BUTT WELD OPERATED GROUNDING WITH PERMANENT BACK-UP RING 3. PIPE ON EACH SIDE OF A g,y�B� ADDITIONAL Project No.: 119025 CIRCUMFERENTIAL WELD O.D. 6. PRESSURE TYPE TERMINALS SHALL BE ELECTRODE NET GROUNDING Date of Issuance: 01/22/2021 SPLICE DETAIL SHALL HAVE THE SAME SUPPLIED AFTER CONTACTORS FOUNDABIION) ELECTRODE OUTSIDE DIAMETER AT THE I Project Milestone: Permit Set WELD SEE DETAIL T2 J— FOR BASE REVISED JUN 2016 _ _ REVISED 2013 STREET LIGHTING CITY OF MERIDIAN STANDARD DRAWING NO. CITY OF MERIDIAN STANDARD DRAWING NO. REVISED JUN 2016 DETAILS SUPPLEMENTAL SUPPLEMENTAL STREET LIGHTING SERVICE CITY OF MERIDIAN STANDARD DRAWING NO. SPECIFICATIONS DAVIT POLE SPECIFICATIONS SUPPLEMENTAL T4 T 6 STREET LIGHT BASE LOCATIONS7QTO THE IDAHO STANDARDS FOR TO THE IDAHO STANDARDS FOR WIRING DIAGRAMSPECIFICATIONS (� PUBLIC WORKS CONSTRUCTION PUBLIC WORKS CONSTRUCTION TO THE IDAHO STANDARDS FOR E2ml O PUBLIC WORKS CONSTRUCTION