Loading...
ACHD Transmittal (A-2020-0190)Applicant name:MARLA CARSON, NEUDESIGN ARCHITECTURE Phone:2088842824 Applicant address:725 E. 2ND ST.Zip:83642 Email:mcarson@neudesignarch.com Owner name:Phone:Fax: Owner address:Zip:Email: Administrative Applicant Information Type of Review Requested File number:A-2020-0190 Assigned Planner:Cameron Scott Related Files: Subject Property Information Location/street address:729 E SCHILLER LN Assessor's parcel number(s):R5741320020 Township, range, section:3N1E18 Agent name (e.g. architect, engineer, developer, representative):MARLA CARSON Firm name:NEUDESIGN ARCHITECTURE Phone:2088842824 Fax:208 Address:725 E. 2ND ST.Zip:83642 Email:mcarson@neudesignarch.com Contact name:Phone:Fax: Contact address:Zip:Email: Project/Application Name:Minert Office Building - DES, CZC Description of Work:3867 SF two story office building. Pad site ready in subdivision with two other buildings with same owner. Project Description Planning Division ADMINISTRATIVE APPLICATION 33 E Broadway Avenue, Suite 102ƔMeridian, Idaho 83642 Phone: (208)884-5533ƔFacsimile: (208) 888-6854ƔWebsite: www.meridaincity.org 1 APPLICATION TYPES Is this application exempt from fees?:No Certificate of Zoning Compliance - CZC:CHECKED Does project have prior approval?:Yes Design Review - DES:CHECKED ADDRESS VERIFICATION Address Verification Permit Number:LDAV-2020-0152 TYPE OF USE PROPOSED Office:CHECKED PROPERTY INFORMATION General Location:SW corner of Schiller Ln & Stratford Dr. Current Land Use:Vacant Total Acreage:.442 Prior Approvals (File Numbers):N/A ZONING DISTRICT(S) C-G:CHECKED PROJECT INFORMATION Site Plan Date (MM/DD/YYYY):06/23/2020 Landscape Plan Date (MM/DD/YYYY):06/23/2020 Elevations Date (MM/DD/YYYY):06/23/2020 Percentage of Site Devoted to Building:11 Percentage of Site Devoted to Landscaping:52 Percentage of Site Devoted to Paving:37 Who will own and Maintain the Pressurized Irrigation System in this Development:yes Irrigation District:Nampa Meridian Irrigation Primary Irrigation Source:Nampa Meridian Irrigation Secondary Irrigation Source:City Water Square Footage of Landscaped Areas to be Irrigated by City Water Connection:N/A Proposed Building Height:25' Existing Floor Area (If Applicable):0 Gross Floor Area Proposed:6867 Number of Standard Parking Spaces Provided:19 Number of Compact Parking Spaces Provided:0 Number of Employees:30 Number of Residential Units:0 Minimum Square Footage of Living Area (Excluding Garage):0 Gross Density:11% Net Density:11% Application Information 33 E Broadway Avenue, Suite 102ƔMeridian, Idaho 83642 Phone: (208)884-5533ƔFacsimile: (208) 888-6854ƔWebsite: www.meridaincity.org 2 TIME EXTENSION INFORMATION Number of months extension:24 APPLICATION DISCLAIMER I have read and accept the above terms:CHECKED Your signature:Marla Carson 33 E Broadway Avenue, Suite 102ƔMeridian, Idaho 83642 Phone: (208)884-5533ƔFacsimile: (208) 888-6854ƔWebsite: www.meridaincity.org 3       Date: March 11, 2020      City of Meridian   Planning Division   33 E. Broadway   Meridian, ID 83642      Re: CZC Narrative Letter     Minert office includes the final office in the development of the Minert Subdivision on Schiller Lane in Meridian.   The office will be very similar in design to the office already constructed on the same lot. The look will be similar   with a few revisions to the windows and color palette so the building will be cohesive to the development and   yet have its own identity in the mix.     The new office building will be a two story building, 3867 sf feet, constructed of wood with stucco and board   and batten siding. Construction will be V-B. The site work, including parking lot are existing. The site is pad site   ready. Approved civil drawings for the project will be included in the submittal. The building meets the zoning   requirements, parking requirements. Landscaping is predominately existing, although some plantings will be   added to surround the building.     Thank you for your consideration,       Marla Carson   Cc: File #20009           Date: March 11, 2020      City of Meridian   Planning Division   33 E. Broadway   Meridian, ID 83642      Re: Design Review Narrative Letter     Cohesive Design: The building has vertical connections to the ground through use of a 3’-0” wainscotting.   There are horizontal and vertical divisions in the walls planes throughout the facade on all sides. Fenestration is   30% of the first floor facade. Roof elements include a hip roof at the second floor and shed roofs at the first   floor entry and rear exit.     Building Scale: The facade has a variety of elements that break up the building. There are pilasters,   wainscotting, doors, windows, and material changes that provide a variation throughout the planes of the   exterior wall. The pilasters provide vertical banding. The trim at the first and second floors provide horizontal   banding. There are canopies at the front and rear points of entry that denote entry and provide further breaks   in the plane of the elevation.     Building Form: The base middle and top of the facade are treated with different materials to create a wall with   a variation of materials and colors. Pilasters are used to further break up the facade with a vertical element.       Architectural Elements: The AC condensing unit is screened by landscaping and located away from the   primary entrance to the building.     Materials: Quality materials are used to construct the office to provide a texture and style that is attractive in   appearance. Stucco walls and trims, batten & board siding and 30 year architectural shingle are provided. A   palette of neutral toned greys and whites are used to provide a variation in the horizontal and vertical material   changes.     Signs and Lighting: Site lighting is existing. Building lighting is to match existing buildings in the development. A   low impact wall sconce will be provided at entries around the building. Additional wall lights are provided to   provide a subtle even wash of light around the building for safety and to add to the look of the building during   evening hours.     Parking lots are existing. Pedestrian walkways connect the entries to the existing sidewalk adjacent to parking   and connect to the existing street sidewalks.       Thank you for your consideration,     Marla Carson Cc: File #20009   DN GENERAL NOTES: A. THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND REPORT AND DISCREPANCIES WITH THE DRAWINGS TO THE ARCHITECT PRIOR TO THE BEGINNING OF CONSTRUCTIONALL GRADES ARE APPROXIMATE, VERIFY IN FIELD B. ALL PLANTS, TREES AND HARDSCAPING TO REMAIN UNLESS OTHERWISE NOTED. PROTECT FROM DAMAGE DURING CONSTRUCTION. REPLACE AS REQUIRED C. PRIOR TO CERTIFICATE OF OCCUPANCY, REPLACE ANY DAMAGED EXISTING HARDSCAPING (ASPHALT, CONCRETE, CURBS, ETC.) AS REQUIRED D. PROVIDE SECURE BICYCLE PARKING IN CLOSE PROXIMITY TO BUILDING ENTRANCES MEETING ADA REQUIREMENTS. THESE FACILITIES SHALL NOT OBSTRUCT PEDESTRIAN WALKWAYS, PUBLIC SIDEWALKS, OR BUILDING ENTRANCE. EACH CONSTRUCTED FACILITY SHALL SUPPORT THE BICYCLE AND ALLOW THE OWNER OF, TO LOCK FRAME AND FRONT WHEEL WITH ONE LOCK. SITE ANALYSIS: SITE CHARACTERISTICS ZONING DISTRICT: C-G LOT AREA: .442 -19,297 SF BUILDING AREA: 2030 SF (FIRST FLOOR) 11% LANDSCAPE: 10,036 SF 52% PAVEMENT: 7231 SF 37% PARKING STALLS: (REFER TO CODE SECTION) CALCULATION:3,867/500 = 8 STALLS REQUIRED STANDARD STALLS:8 REQUIRED ADA STALLS:1 PROVIDED STANDARD STALLS:18 PROVIDED ADA STALLS:1 REQUIRED BIKE PARKING: 1 PER 25 (1) REQ'D PROVIDED BIKE PARKING: 1 SETBACKS: 10' STREET, 0' INTERIOR (PER RECORDED PLAT) EXISTING BUILDING EXISTING BUILDING NEW BUILDING 2 ' - 0 " 5 ' - 0 " 1 2 3 4 5 6 7 8 9 10 11 5 YW BB FG FG BX BX BX FG BX FG BX BB YW YW BB BB EEE E E E EE E E E E E E E E ETG 12 13 13 E A S E M E N T 1 0 ' - 0 "EASEMENT10' - 0"14 15 LANDSCAPE NOTES 1. ALL PLANT MATERIAL SHALL CONFORM TO THE AMERICAN NURSERYMAN STANDARDS FOR TYPE AND SIZE SHOWN. PLANTS WILL BE REJECTED IF NOT IN A SOUND AND HEALTHY CONDITION. ALL PLAN MATERIAL SHALL BE GRADE #1 OR BETTER. 2. ALL PLANTING BEDS AND TREE WELLS IN LAWN AREAS (WELLS TO BE 3' IN DIAMETER) SHALL BE COVERED WITH A MINIMUM OF 3" DEPTH OF BLACK AND TAN ROCK MULCH, PLACED OVER DEWITT'S WEED BARRIER FABRIC (OR EQUAL). SUBMIT SAMPLE FOR APPROVAL BY OWNER. 3. ALL LAWN AREAS SHALL BE SODDED WITH 100% TURF TYPE TALL FESCUE (FESTUCA ARUNDINACIA). CONTRACTOR SHALL VERIFY AND MATCH THE VARIETY EXISTING IN THE DEVELOPMENT. 4. ALL PLAN MATERIAL SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR BEGINNING AT THE DATE OF ACCEPTANCE BY OWNER. REPLACE ALL PLANT MATERIAL FOUND DEAD OR NOT IN A HEALTHY CONDITION IMMEDIATELY WITH THE SAME SIZE AND SPECIES AT NO COST TO THE OWNER. 5. PLANTING BACKFILL FOR TREES AND PLANTING BEDS SHALL BE 5 PARTS TOPSOIL AND 1 PART COMPOST WITH STRAW. STAKE ALL TREES PER DETAILS. 6. ALL SODDED LAWN AREAS SHALL HAVE 6" OF TOPSOIL AND ALL PLANTING BEDS SHALL HAVE 12" OF TOPSOIL (MINIMUM). TOPSOIL SHALL BE A LOOSE, FRIABLE, SANDY LOAM, CLEAN AND FREE OF TOXIC MATERIALS, NOXIOUS WEEDS, WEE SEEDS, ROCKS, GRASS, OR OTHER FOREIGN MATERIAL LARGER THAN 1" IN ANY DIMENSION, A pH FROM 5.5 TO 7.0. TOP SOIL FROM SITE SHALL BE USED, IF MEETING THESE STANDARDS. PLACE 1/2" COMPOST OVER ALL LANDSCAPED AREAS AND ROTOTILL INTO TOP 4". SPREAD, COMPACT, AND FINE GRADE TOPSOIL TO A SMOOTH AND UNIFORM GRADE, 1" BELOW SURFACE OF WALKS AND CURBS IN AREAS TO BE SODDED AND 3" IN PLANTING BED AREAS. 7. FERTILIZE ALL TREES AND SHRUBS WITH AGRIFORM" PLANTING TABLETS, 21 GRAM. QUANTITY PER MANUFACTURER'S RECOMMENDATION. 8. PLANT MATERIAL SHALL NOT BE SUBSTITUTED WITHOUT THE WRITTEN PERMISSION OF OWNER. SUBMIT NAMES OF THREE SUPPLIERS CONTACTED IF SUBSTITUTION IS REQUESTED AND PLAN MATERIAL SPECIFIED IS NOT AVAILABLE. 9. SHRUB PLANTING BEDS SHALL BE SHOVEL EDGED TO CREATE A DISTINCT SEPARATION OF LANDSCAPE TYPES. 10. IMMEDIATELY CLEAN UP ANY TOPSOIL, OR OTHER DEBRIS ON SITE CREATED FROM LANDSCAPE OPERATION AND DISPOSE OF PROPERLY OFF SITE. 11. ALL LANDSCAPE AREAS SHALL HAVE AN STATE OF THE ART AUTOMATIC UNDERGROUND SPRINKLER SYSTEM WHICH INSURES COMPLETE COVERAGE AND IS PROPERLY ZONED FOR REQUIRED WATER USES AND HAS A WEATHER STATION CAPABLE OF TURNING OFF FOR RAIN/FREEZE EVENTS. COORDINATE THE POC WITH THE CIVIL CONSTRUCTIONS PLANS, CITY ENGINEER AND OWNER. CONTRACTOR SHALL INSURE THAT THE BACKFLOW IS INSTALLED PER CITY CODES. 12. COORDINATE ALL DRAINAGE AREAS AND UTILITIES WITH TREE LOCATIONS AND ADJUST PER FIELD CONDITIONS. 13. ALL EXISTING TREES SHOWN TO REMAIN SHALL BE RETAINED AND PROTECTED THROUGH OUT CONSTRUCTION. PLANT SCHEDULE KEY COMMON NAME BOTANICAL NAME PLANTING SIZE E EXISTING TREE BX BOXWOOD BUXUS 2 GAL. BB BURNING BUSH EUONYMUS ALATUS 5 GAL. TG TURF GRASS CYNODON DACTYLON 1 GAL. YW YEW SHRUB TAXUS 2 GAL. FG FOUNTAIN GRASS PENNISETUM SETACEUM 5 GAL. ASTM 55 SCH. 40 GALV. O.D. STEEL PIPE FACTORY PRIMED, PAINTED BLACK 4" CONCRETE SIDEWALK OVER COMPACTED FILL (95% MIN) 12 "Ø x 1'-0" DEEP CONCRETE BASE ANCHOR3' - 8"2' - 6" PRUNE ANY DEAD OR BROKEN BRANCHES TO ANSI A300 PRUNING STANDARD. IF IMPROPERLY PRUNED AS DETERMINED BY THE ARCHITECT OR LANDSCAPE DESIGNER, THE TREE SHALL BE REMOVED AND REPLACED AT NO COST TO THE OWNER OR DESIGNERS 3" DIA. WOOD TREE STAKES (LENGTH AS REQUIRED) SET STAKES PARALLEL TO PREVAILING WIND. ENSURE WOOD STAKES DO NOT PENETRATE ROOTBALL AFTER INSTALLATION, REMOVE TRUNK GUARD DECORATIVE ROCK OR MULCH PER PLANS WIDEN HOLD IS SOIL IS COMPACTED PER GROWER'S INSTRUCTIONS REMOVE BURLAP AND WIRE BASKET DO NOT REMOVE MAIN LEADER KEEP MULCH/ROCK AWAY FROM ROOT COLLAR ADDITIONAL NOTES: • AFTER INSTALLATION THE TREE MUST BE WATER WITHIN THE FIRST HOUR AND AGAIN WITHIN 12-18 HOURS. • IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSURE THAT ALL TREES ARE PLANTED CORRECTLY PER GROWERS INSTRUCTIONS AND REMAIN STRAIGHT FOR 1 YEAR AFTER INSTALL OR THE WARRANTY PERIOD, WHICHEVER IS GREATER. A WHICH POINT ALL STAKES WILL BE REMOVED. • AT ALL LOCATIONS WHERE A TREE IS LOCATED WITHIN 8' OR LESS OF A ROAD OR DRIVEWAY, A TREE ROOT BARRIER SHALL BE INSTALLED. THE ROOT BARRIER SHALL BE INSTALLED AT THE BACK OF CURB AND EDGE OF SIDEWALK. ALL TREE INSTALLATIONS SHALL CONFORM TO ALL AGENCY APPROVAL REQUIREMENTS, CONTRACTOR SHALL VERIFY PRIOR TO ANY INSTALLATIONS.6"-8"FINISH GRADE BACKFILL W/ APPROVED SOIL BREAK UP ROOT BALL TO PROMOTE ENCOURAGE ROOT GROWTH INTO THE SURROUNDING SOIL PRUNE ANY DEAD OR BROKEN BRANCHES TO ANSI A300 PRUNING STANDARD. IF IMPROPERLY PRUNED AS DETERMINED BY THE ARCHITECT OR LANDSCAPE DESIGNER, THE TREE SHALL BE REMOVED AND REPLACED AT NO COST TO THE OWNER OR DESIGNERS BREAK UP ROOT BALL TO PROMOTE ENCOURAGE ROOT GROWTH INTO THE SURROUNDING SOIL BACKFILL W/ APPROVED SOIL WIDEN HOLD IS SOIL IS COMPACTED PER GROWER'S INSTRUCTIONS DECORATIVE ROCK OR MULCH PER PLANS KEEP MULCH/ROCK AWAY FROM ROOT COLLAR ADDITIONAL NOTES: • AFTER INSTALLATION THE TREE MUST BE WATER WITHIN THE FIRST HOUR AND AGAIN WITHIN 12-18 HOURS. • IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSURE THAT ALL TREES ARE PLANTED CORRECTLY PER GROWERS INSTRUCTIONS.