SECOND FLOOR PLANDN GENERAL NOTES: A. VERIFY ALL DIMENSIONS IN FIELD AND NOTIFY ARCHITECT OF DISCREPANCIES PRIOR TO FABRICATION OR INSTALLATION B. TYPICAL DIMENSION LOCATIONS ARE TO F.O. CONCRETE OR GRID LINES OR LEFT/TOP SIDE OF F.O. STUD, U.N.O. (TO F.O. STRUCTURAL MEMBERS, NOT TO F.O. FINISH MATERIALS C. PROVIDE SOLID BLOCKING IN WALLS FOR ITEMS SUCH AS GRAB BARS, TOILET PARTITIONS, PAPER DISPENSERS, WALL-HUNG TOILETS, AND ETC. D. ALL STUD FRAMED INTERIOR PARTITIONS WALLS SHALL BE BRACED TO THE UNDERSIDE OF DECK/STRUCTURE ABOVE E. ALL INTERIOR WALLS SHALL BE FILLED WITH SOUND BATT INSULATION F. CONTRACTORS SHALL ADHERE TO ALL CODES, RULES AND REGULATIONS FOR IBC AND SPECIFIC TRADE CODES G. DO NOT SCALE DRAWINGS H. LARGE SCALE DRAWINGS TAKE PRECEDENCE OVER SMALLER SCALE DRAWINGS U.N.O. I. ALL EXPOSED GWB EDGES TO HAVE METAL EDGE TRIM, TYP. J. LIGHTER LINES TYPICALLY INDICATE OWNER SUPPLIED ITEMS U.N.O. A-211 3 A-211 A-212 A-212 1 2 2 2 B A 1 1752 SF OPEN WORK AREA 207 46 SF M.R.R. 205 45 SF W.R.R. 204 165 SF STAIRS 201 115 SF OFFICE 206 83 SF OFFICE 202 131 SF HALL 203 74' - 2 1/2"10 1/2"73' - 0"4"1' - 7 1/2"21' - 4 1/2"2' - 6"45' - 4"2' - 2"11' - 7 1/2"9' - 9"5' - 0"3' - 0"1' - 9"4' - 0"3' - 0"4' - 7 1/2"4' - 8"3' - 0"3' - 0"3' - 0"3' - 0"3' - 0"3' - 0"3' - 0"3' - 0"3' - 0"3' - 0"3' - 0"3' - 0"3' - 0"1' - 8"4"35' - 0"4" 2' - 2"30' - 8"2' - 2" 6' - 8"3' - 0"5' - 9"4' - 9"3' - 0"7' - 6" 36' - 2 1/2" 4"35' - 0"10 1/2" 2' - 2"31' - 2 1/2"1' - 7 1/2" 18' - 10 1/2"12' - 4"4"73' - 0"4"2' - 2"9' - 5"11' - 5"2' - 6"45' - 4"2' - 2"9' - 2"3' - 1"3' - 0"3' - 1"1' - 8"3' - 0"3' - 0"3' - 0"3' - 0"3' - 0"3' - 0"3' - 0"3' - 0"3' - 0"3' - 0"3' - 0"3' - 0"3' - 0"4' - 8"9' - 2"4' - 1"14' - 0"6' - 7"4' - 6"9' - 11" 1 A-311 __________ 2 A-311 __________7' - 1"10 1/2"10 1/2" 10' - 7"7' - 0"6' - 10"10' - 7" __________ A-421 1 __________ A-431 2 1' - 11"3' - 0"13' - 11 1/2" 15' - 3"15' - 5"0"7' - 8"1' - 9"CLIENT:JOB NUMBER CONSULTANT 725 E 2nd St Meridian, ID 83642 208.884.2824 PROFESSIONAL SEAL THIS DOCUMENT IS THE PROPERTY OF NEUDESIGN ARCHITECTURE, LLC AND IS NOT TO BE DUPLICATED WITHOUT WRITTEN AUTHORIZATION. © NEUDESIGN ARCHITECTURE LLC DRAWN BY N O T FO R P ER M IT20009MINERT OFFICE BUILDING729 E. SCHILLER LN MERIDIAN, ID 83642A-112JOSH TANNERSECOND FLOOR PLAN Author FLOOR PLAN NOTES # Note NO. DESCRIPTION DATE F DR Revisions 4.1.21 E DR Revisions 10.21.20 D Coordination Set 10.20.20 C DR Revisions 10.14.20 B Design Review 06.23.20 A Schematics 01.28.20 1/4" = 1'-0"1 SECOND FLOOR PLAN