Loading...
ROOF PLAN2 B A 1 1' - 8"2' - 0"2' - 0" 2' - 0"2' - 0"1' - 1 1/2"1' - 8"1' - 8" 1' - 1 1/2" 1' - 1 1/2" 1' - 8"1' - 8" 1' - 1 1/2"3" / 1'-0"3" / 1'-0"3" / 1'-0"3" / 1'-0"4' - 0" 4' - 0" 1' - 1 1/2" GENERAL NOTES: A. PROVIDE 50% OF REQUIRED 1sf/ 300SF OF ATTIC FLOOR SPACE ROOF VENTING ABOVE THE EAVES w/ RIDGE VENTING. PROVIDE ROOF VENTS @ 10' FROM INSIDE F.O. WALL IN LIEU OF SOFFIT VENTS. B. PROVIDE GUTTERS AS SHOWN, COORDINATE DOWNSPOUTS WITH SITE DRAINAGE PLAN. CONNECT WITH SEEPAGE BEDS. C. PROVIDE ICE/WATER BARRIER @ EAVES TO 2' -0" FROM BUILDING PERIMETER & AT ALL CRICKETS D. STANDARD EAVE DEPTH SHALL BE 1'-4" OR 2'-0". SEE REFLECTED CEILING PLAN FOR MORE INFORMATION. DIMENSIONS MAY NOTE AN ADDITIONAL 0'-3" WHERE STONE VENEER ON ADJACENT WALLS APPLY E. ALL EXTERIR EAVES TO BE CONTINUOUS ALUMINUM SOFFIT MATERIAL F. ROOF SHALL MEET CLASS B CLASSIFICATION PER 2012 IBC G. NO ATTIC SPACE SHALL BE LARGER THAN 3,000SF. PROVIDE A DRAFT STOP AS REQUIRED w/ DOOR AND SELF CLOSING HARDWARE. 30-YEAR ARCHITECTURAL ASPHALT CLASS B ROOF SHINGLE 15# FELT ROOF SHEATHING PER STRUCTURAL DRAWINGS MANUFACTURED WOOD ROOF TRUSS, SPACING PER STRUCTURAL / TRUSS MANUFACTURER DRAWINGS 5/8" TYPE "X" EXTERIOR GWB SHEATHING PAINTED HARDBOARD SOFFIT PANELING 2X4 STUDS AT 1'-4" O.C. SUPPORTED BY WALL FRAMING 5/8" TYPE "X" EXTERIOR GWB SHEATHING 30-YEAR ARCHITECTURAL LAMINATED FIBERGLASS CLASS B ROOF SHINGLE 15# FELT (USE ICE BARRIER FROM 24" INSIDE EXTERIOR WALLS TO EDGE OF EAVE) ROOF SHEATHING PER STRUCTURAL DRAWINGS MANUFACTURED WOOD ROOF TRUSS, SPACING PER STRUCTURAL / TRUSS MANUFACTURER DRAWINGS (2) LAYERS OF 5/8" TYPE 'X' GWB PRIME AND PAINTMAX.2"VENTILATION BAFFLE 30-YEAR ARCHITECTURAL ASPHALT CLASS B ROOF SHINGLE 15# FELT ROOF SHEATHING PER STRUCTURAL DRAWINGS MANUFACTURED WOOD ROOF TRUSS, SPACING PER STRUCTURAL / TRUSS MANUFACTURER DRAWINGS PAINTED HARDBOARD SOFFIT PANELING VENTILATION BAFFLEMAX2"CLIENT:JOB NUMBER CONSULTANT 725 E 2nd St Meridian, ID 83642 208.884.2824 PROFESSIONAL SEAL THIS DOCUMENT IS THE PROPERTY OF NEUDESIGN ARCHITECTURE, LLC AND IS NOT TO BE DUPLICATED WITHOUT WRITTEN AUTHORIZATION. © NEUDESIGN ARCHITECTURE LLC DRAWN BY N O T FO R P ER M IT20009MINERT OFFICE BUILDING729 E. SCHILLER LN MERIDIAN, ID 83642A-131JOSH TANNERROOF PLAN MJC 1/4" = 1'-0"1 ROOF PLAN NO. DESCRIPTION DATE C DR Revisions 10.21.20 B Coordination Set 10.20.20 A Schematics 01.28.20 ROOF PLAN NOTES # Note 1 1/2" = 1'-0"4 ROOF TYPE R2 1 1/2" = 1'-0"3 ROOF TYPE R3 1 1/2" = 1'-0"2 ROOF TYPE R21