Loading...
FIRST FLOOR PLANUP A-211 3 A-211 A-212 A-212 1 2 2 2 B A 1 45 SF W.R.R. 104 46 SF M.R.R. 105199 SF HALL 103 139 SF BREAK 107 13 SF W/H 108 119 SF CONFERENCE 106 111 SF STAIRS 102 56 SF ENTRY 101 157 SF FILES 109 72 SF MECH/UTILITY 110 1378 SF OPEN WORK AREA 11110 1/2"73' - 0"4"1' - 7 1/2"21' - 4 1/2"2' - 6"45' - 4"2' - 2"7' - 2"38' - 2"2' - 6"1' - 3"8' - 6"11' - 7 1/2"2' - 10"3' - 0"2' - 8"6"3' - 0"1' - 0"3' - 0"4' - 1 1/2"4' - 8"3' - 0"3' - 0"3' - 0"3' - 0"3' - 0"3' - 0"3' - 0"3' - 0"3' - 0"6' - 6"4"35' - 0"4" 2' - 2"6' - 8"3' - 0"10' - 2 1/2"3' - 0"7' - 9 1/2"2' - 2"4"73' - 0"4"2' - 2"9' - 5"2' - 6"8' - 11"2' - 6"45' - 4"2' - 2"5' - 2"40' - 2"5' - 10"3' - 1"2' - 6"7' - 8"1' - 9"4' - 3"3' - 0"1' - 3"3' - 0"3' - 0"3' - 0"3' - 0"3' - 0"3' - 0"3' - 0"3' - 0"3' - 0"4' - 8"4"35' - 0"10 1/2" 2' - 2"31' - 2 1/2"1' - 7 1/2" 18' - 10 1/2"12' - 4" 10' - 11"3' - 0"1' - 0"3' - 0"11 1/2" 1 A-311 __________ 2 A-311 __________ __________ A-421 1 __________ A-431 1 A-421 10 1' - 0"4' - 2"1' - 5" 5' - 4"9' - 8"9' - 2"4' - 6 1/2"73' - 8"36' - 2 1/2" GENERAL NOTES: A. VERIFY ALL DIMENSIONS IN FIELD AND NOTIFY ARCHITECT OF DISCREPANCIES PRIOR TO FABRICATION OR INSTALLATION B. TYPICAL DIMENSION LOCATIONS ARE TO F.O. CONCRETE OR GRID LINES OR LEFT/TOP SIDE OF F.O. STUD, U.N.O. (TO F.O. STRUCTURAL MEMBERS, NOT TO F.O. FINISH MATERIALS C. PROVIDE SOLID BLOCKING IN WALLS FOR ITEMS SUCH AS GRAB BARS, TOILET PARTITIONS, PAPER DISPENSERS, WALL-HUNG TOILETS, AND ETC. D. ALL STUD FRAMED INTERIOR PARTITIONS WALLS SHALL BE BRACED TO THE UNDERSIDE OF DECK/STRUCTURE ABOVE E. ALL INTERIOR WALLS SHALL BE FILLED WITH SOUND BATT INSULATION F. CONTRACTORS SHALL ADHERE TO ALL CODES, RULES AND REGULATIONS FOR IBC AND SPECIFIC TRADE CODES G. DO NOT SCALE DRAWINGS H. LARGE SCALE DRAWINGS TAKE PRECEDENCE OVER SMALLER SCALE DRAWINGS U.N.O. I. ALL EXPOSED GWB EDGES TO HAVE METAL EDGE TRIM, TYP. J. LIGHTER LINES TYPICALLY INDICATE OWNER SUPPLIED ITEMS U.N.O. BUILDING R-VALUE ANALYSIS: EXTERIOR WALLS:BATT INSULATION ROOFS:BLOWN IN CELLULOSE FOUNDATION:RIGID INSULATION FLOOR: WINDOWS:SEE COMCHECK REQUIREMENTS DOORS:SEE COMCHECK REQUIREMENTS IBC 2018 -AREA, BUILDING. The area included within surrounding exterior walls (or exterior walls and fire walls) exclusive of vent shafts and courts. First Floor -sf Second Floor -sf TOTAL -sf BUILDING SQUARE FOOTAGE ANALYSIS: Allowable Floor Area: The area includes the exterior walls to the face of exterior finish. Used to calculate construction cost, bank appraisal, and tax assessor value First Floor 2,555 sf Second Floor 2,555 sf TOTAL 5,110 sf Gross Building Area:CLIENT:JOB NUMBER CONSULTANT 725 E 2nd St Meridian, ID 83642 208.884.2824 PROFESSIONAL SEAL THIS DOCUMENT IS THE PROPERTY OF NEUDESIGN ARCHITECTURE, LLC AND IS NOT TO BE DUPLICATED WITHOUT WRITTEN AUTHORIZATION. © NEUDESIGN ARCHITECTURE LLC DRAWN BY N O T FO R PER M IT20009MINERT OFFICE BUILDING729 E. SCHILLER LN MERIDIAN, ID 83642A-111JOSH TANNERFIRST FLOOR PLAN Author 1/4" = 1'-0"1 FIRST FLOOR PLAN FLOOR PLAN NOTES # Note NO. DESCRIPTION DATE F DR Revisions 4.1.21 E DR Revisions 10.21.20 D Coordination Set 10.20.20 C DR Revisions 10.14.20 B Design Review 06.23.20 A Schematics 01.28.20