CS-101 Civil Site Plan(SCALE IN FEET)
1:20 (22x34 FULL SIZE)20 10 60200
SITE PLAN
CONCRETE SIDEWALK PER ISPWC SD-709.
SCORED CONCRETE 5' WALK THROUGH DRIVE
5.00'
35.52'
22.03'
STREET LIGHT
5.00'
21.16'
6.00'
7.00'
9.00'
12.00'
18.00'
5.00'
STREET LIGHT
STREET LIGHT
STREET LIGHT
68.00'
75.00'
11.49'
25.18'
VALLEY GUTTER PER ISPWC SD-708
XXXXXXXXXXXEP EP EP EP EP
GAS GAS GAS GAS GAS GAS GAS
SSSSGASGAS
FO
FO FO
FO
SS SS SS SS SS SS SS SS SS SS SS SS
PIRR PIRR PIRR PIRR PIRR PIRR PIRR PIRR PIRR PIRR
D D
RRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRE
UGPUGPUGPTELTELTELTEL TEL TEL TEL TELUGPUGPUGPUGP UGPCABLECABLECABLECABLE
CABLECABLECABLEIE=86.18 (N)
EXISTING TREES AND LANDSCAPE
XXXXXXXXXXXEP EP EP EP EP
GAS GAS GAS GAS GAS GAS GAS
SSSS SS SS SS SS SS SS SS SS SS SS SS
SSWGASGAS
FO
FO FO
FO
PIRR PIRR PIRR PIRR PIRR PIRR PIRR PIRR PIRR PIRR
D D
RRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRE
UGPUGPUGPTELTELTELTEL TEL TEL TEL TELUGPUGPUGPUGP UGPCABLECABLECABLECABLE
CABLECABLECABLEIE=86.18 (N)
PHARMACY
PARKING EMPLOYEE PARKINGSDSDSDSDSDS
D
S
DSDSDSD
SD
SD SD
SD SD
PIRRPIRRPIRRPIRRPIRRPIRRPIRRWWWS
S
S
S
S
S
S
S
S
S
S
S
W W W W W W W W
POLE SIGN
12.50'1.00'
OVERLAND RD.
20.00'
6.00'
25.00'
17.00'
8.00'
STREET LIGHT
STREET LIGHT
13.96'
14.03'
0.51'
9.75'
July 19
PLOTTED BY: CALEB KENYON DATE PLOTTED: 7/11/2019 11:16:12 AM PATH: A:\ABCO ENGINEERING\JOBS LANDED\174552Z--E OVERLAND ROAD PHARMACY (LAWSON)\00 ABCO CAD\17-4552Z - 03 - CS-101.DWGFILE NUMBER:
SHEET NUMBER:
DESIGNED BY:
DATEDESCRIPTIONDATEREVISIONSBYNO.DRAWN BY:ABCOENGINEERING119 N. Midland Blvd.
Nampa, Idaho 83651
Phone (208) 955-8126
E. OVERLAND ROADC. KENYON
CS-101MERIDIAN, IDSITE PLANTYNLO INC.3 OF 6 ADA COUNTYE. OVERLAND ROAD PHARMACYK. NEWKIRK
17-4552Z
LEGEND
CENTER LINE
EDGE OF PAVEMENT
EDGE OF GRAVEL
FENCE LINE
GAS LINE
OVERHEAD POWER LINE
UNDERGROUND POWER
PROPERTY LINE
STORMDRAIN LINE
SEWER LINE
TELEPHONE LINE
WATER LINE
PRESSURE IRRIGATION LINE
GRADE BREAK LINE
CONCRETE
EP EP
EG EG
X X
GAS GAS
OHP
SD SD
SS SS
TEL TEL
W W
PIRR PIRR
CALL BEFORE YOU DIG!
1.THE LOCATION OF EXISTING UNDERGROUND UTILITIES SHOWN
ARE APPROXIMATE LOCATIONS ONLY. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO INFORM ALL UTILITY
COMPANIES OF THE CONSTRUCTION SCHEDULE. THE
CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL
EXISTING UTILITIES BEFORE COMMENCING WORK. THE
CONTRACTOR IS RESPONSIBLE FOR ANY AND ALL DAMAGE
WHICH MAY OCCUR BY FAILURE TO EXACTLY LOCATE AND
PROTECT ALL UTILITIES.
2.CONTRACTOR SHALL CONTACT DIGLINE 48 HOURS PRIOR TO ANY
EARTH DISTURBING ACTIVITIES ON SITE, AND REQUEST LOCATE OF
UNDERGROUND UTILITIES.
*The 811 logo is a registered trademark of the CGA.
Know what's below.
before you dig.CallR
UGP
1 7 / 19 CK CITY COMMENTS